Military Engineer Services Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date4 Sep 2024
Closing Date2 Oct 2024
Tender Amount₹ 20,00,000
Costs
EMD
₹ 40,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_671817_1Bid Award Id
ViewTender No
82452/PAN/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Corrigendum. The bidders are advised to go through the amendments before quoting
BOQ Items
Supply only:- HT 11 KV Gang operated air break switch outdoor type off load, disconnecting switch. Triple pole, each pole consist of galvanized steel base, HT insulators as per B.S.S./I.S. non ferrous knife and spring loaded contact, arcing horns of adequate section to break magnetizing current of the transformers horizontal GI pipe of adequate length for phase seperation, adequate length of GI pipes for operation from ground level and operating handle complete in both OFF and ON position. All ferrous parts hot dipped galavanized and non ferrous parta heavily tinned to withstand weather suitable for vertical mounting of capacity 200 Amps.
1
-
-
All as per items No.4 before but of capcity 400 Amps.
1
-
-
Supply only Male contact/ moving contact blade 200/400 Amp.
10
-
-
Supply only Female contact/ fix contact 200/400 Amp.
10
-
-
Supply only Tinned copper flexible jumper 200/400A
8
-
-
Supply only Back connector plate.
8
-
-
Supply only MS jumper carrier.
8
-
-
Supply and fix 11 KV horn gap out door expulsion fuse set of three including taking down exesisting unserviceable.
2
-
-
Dismantling and taking down unserviceable 11 KV horn gap fuse and refixing the same after repairs with replacement of fix top contact/L contact and fix bottom contact.
3
-
-
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth for taking out/laying of under ground cables/pipes etc n. exc 10 sqm on plan and n. exc 1.5 m in depth and getting out and in soft/loose soil.
33.75
-
-
Returning, filling in, including spreading , levelling, watering, and well ramming in layers n-exc 25 cm in soft/loose soil.
25.12
-
-
Removing excavated materials (soil) n-exc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point.
8.63
-
-
Supply and filling gravel of 20mm to 40mm size grade in four pole, two pole, three pole structure complete and cleaning and levelling all as directed.
20
-
-
Supply and speading fine (dry) river sand of approved quality in trenches for cushioning of under ground cable all as directed by engr-in-charge at site Note:- Only puned thickness shall be measured for payment.
8.1
-
-
Supplying and laying un-reinforced precast concrete cable cover (ISI Marked), class HVP, type 1 with size 300mm x 180mm x 40 mm for cable protection.
247
-
-
Supply,laying,testing & commissioning XLPE insulated, PVC bedded, galvanized steel strip or wire armouredarmoured electric power cables (heavy duty) with aluminium conductor, 11000 Volts, grade cross section area 95 Sq mm 3 core laid in trenches/ floor/ walls including taking out unserviceable cable complete all as specified and directed.
100
-
-
Supply, jointing and testing cable jointing kit for 11KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing materils and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm.
1
-
-
All as per item No 20 above but of size 120 sqmm to 185 sqmm.
1
-
-
Supply, jointing and testing cable jointing kit for 11KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing materils and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm.
1
-
-
All as per item No 22 above but 3 core 50 to 95 sq mm
1
-
-
Supply and fixing GI pipe light grade with all fittings fixed on pole or laid in trenches for cable protection of size 100 mm including taking down old pipe.
10
-
-
Comprehensive maintenance of HT VCB Panel of any capacity as below. a)Disconecting of cables from HT VCB panel . b)cheking of earth fault and over current relays.c) testing of relays with the help of relay testing kit (boosting Kit) and resetting of relays as per desire load current reconnecting the cables ,including calibaration of relays, for proper tripping and functioning.d) Testing of CT/PT .e)cleaning of spout, mechanical parts with CRC material, and replacement of U/S parts if required . f) testing of VCB complete for MDO/EDO tripping .g) Checking of heating element and replacement of the same if found unserviceable. h) Checking of all control cables for normal functioning of VCB. j) servicing of breakers mechanical parts including greasing of moving parts and checking of spring charging motor for its proper functioning and testing resetting the same all as directed by Engineer-in-Charge.(Note: Spares required for replacement will be paid and measured separately)
8
-
-
Comprehensive maintenance of HT 11 KV RMU any capacity as below. a)Disconecting of cables from HT rmu panel . b)cheking of earth fault and over current relays.c) testing of relays with the help of relay testing kit (boosting Kit) and restting of relays as per desire load current reconnecting the cables ,including calibaration of relays, for proper tripping and functioning.d) Testing of CT/PT .e)cleaning of spout, mechanical parts with CRC material, and replacement of U/S parts if required . f) testing of VCB complete for MDO/EDO tripping .g) Checking of heating element and replacement of the same if found unserviceable. h) Checking of all control cables for normal functioning of RMU all as directed by Engineer-in-Charge.(Note: (i)Spares i.e. earth fault relay,tripping coil,IDMTL relay required for replacement will be measured and paid separately (ii) any other spare parts required during rectification of work and not mentioned above and required to be replaced shall be replaced by the Contractor without any extra cost and rates are deemed to be included on this account in this item.(iii)Tenderer are advised to visit the site in consultation with Engineer-in-Charge before quoting the unit rate).
5
-
-
Supply only three phase over current and earth fault relay Suitable for CT Secondary 1 Amps or 5 Amps,Aux Supply 77-250V DC/AC (230VAC) suitable for existing breakers including taking down old U/ S relay .Make: Ashida/Crompton/Ariva .
3
-
-
Supply only triping coil DC 24/110 Volts suitable for existing breakers
3
-
-
Supply only IDMTL relay suitable for double over current and earth fault function complete all as directed suitable for existing breakers including taking down U/S relay . Make Ashida,Model No-ADR141S/141C or equivalent of Crompton/Ariva.
1
-
-
M&L for one primer coat,one under coat and one finishing coat of aluminium painting to HT steel tubular poles of single pole and including angle iron cross arms channels clamps etc complete including preparation of old painted surfaces and numbering of single pole upto 11 mtr height all as specified and directed.
25
-
-
All as per item No 30 above but two pole structure upto 11 mtr height
4
-
-
All as per item No 30 above but four pole structure upto 11 mtr height
4
-
-
M&L stay assembly complete with accessories as shown in electrical plate No 1 (Loop type insulators, stay clamps, excavation and concrete measured separately) including 16 mm dia stay rod all as directed by Engineer-in-Charge.
1
-
-
Supply & Fixing ACSR conductor on over head lines including binding wires, jumpers connections all as directed by Engineer-in-Charge including taking down exsisting unserviceable conductor.
0.4
-
-
M& L for stay strand galvanised size 7/3.15 mm including taking down all as directed.
0.2
-
-
S&F loop insulators, vitereous porcelain white brown or green with over all dimension 65x90 mm clearance of hole 16 mm
2
-
-
M&L for Cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers ,welding,bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat , one under coat and one finishing coat of paint.
0.8
-
-
M&L disc insulator, porcelain, vitreous 145 mm hight and 255 mm dia ball and socket type , with single disc assembly & tenson clamps for conductors working pressure 11000 volts white,brown or green all as directed.
9
-
-
M&L for pin type, porcelain, vitreous white, brown or green insulators including one galvanised MS spindle two galvanised iron nut 150 mm height 150 mm dia for 11000 volts grade.
10
-
-
Dismantling of insulators any type any size
21
-
-
M&L danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white with letters figures and conventional skull and bones in signal red color and fixed with MS clamps, bolts and nuts of size HT 25 x 20 cm including taking down rusted danger plate.
10
-
-
Taking out the sample of transformer oil from bottom portion of each transformer at various locations for checking the di-electric strength and acidity test of oil for the presence of moisture, impurities etc before and after including dehydration (filtration) of transformer oil through mobile filtration plant to be toed to respective location duly connecting inlet/outlet to the machinery by switching off HT power supply taking all safety precautions, so as to achieve di-electric strength not less than 40 KV per mm repturing capacity, switch on supply including commissioning of transformer all as directed.
2500
-
-
Supply, fill and topping up transformer oil duly tested for proper di electric strength,upto desired marked level after heating up oil in each transfomer HT switch gear all as directed.
750
-
-
S&F breather Assembly filled with Silica Gel as appproved complete all as speciied and as directed including taking out of ld one upto 315KVA Cap distribution from Transformer.
5
-
-
M&L for replacement of silica gel of transformer breather all as directed.
4
-
-
M&L for Electrical Earthing with GI plate electrode of size 60 Cm X 60 Cm X 6.3 mm thick, burried directly in ground vertically ,erath pit not less than 2.25 mtr.deep below normal ground level with the top edge of the earth plate at a depth not less 1.5 mtr below normal ground lelevel connected to GI stip earth lead of size 32 x6 mm upto 7.5 mtr long distance in 40 mm dia pipe light grade by means of bolts, nuts,washers made of galvanised iron and connected to main control board /switch gear/pannel boards etc. all as specified and shown in Electrical plate No-3 of MES Schedule (SSR) Part-I including necessery excavation and earth work in any type of soil,charcoal dust,salt and watering pipe 20 mm dia medium grade with funnel and PCC 1:2:4 type B1 in chamber RCC 1:2:4 type,B1 cover slab with 6 mm dia mild steel bars at 100 mm center to center both ways and with 6mm dia MS hook complete and PCC cover and testing resistence after taking down old unserviceable earthing pit all as specified and as directed.
2
-
-
Supply and fix in repair porcelain vitreous HT side bushings with copper studs suitable for distribution transfomer of capacity upto 315 KVA after removing the old u/s studs / bushing all as directed for the following capacity transformer including taking out u/s bushing all as specified and directed by engr-in-charge. Lifting the top cover of the transformer complete by disconnection of LT side,after completionof HT stud replacement closing the top cover of the transformer and replacing the damaged gasket complete. Note : Filteration of transformer to be carried out
1
-
-
Supply and fix in repair porcelain vitreous LT side bushings with copper studs suitable for distribution transfomer of capacity upto 315 KVA after removing the old u/s studs / bushing all as directed for the following capacity transformer including taking out u/s bushing all as specified and directed by engr-in-charge. Note :- LT bushing will be replaced during filteration of transformr oil by draining out transformer oil from the existing level upto conservator of the transformer or during the leakage arrest work of the transformer.
1
-
-
M & L for arresting the leakage of transformer oil after drain out transformer oil , switching off HT power supply taking all safety precautions, including provision of gasket and re fiil transformer oil after arrest the leakage including testing and commissioning of transformer upto 315 KVA capacity. Note : The above shall be carried out before filteration of transformer oil
1
-
-
Supply only HT digital type ammeter suitable for CT ratio 5 Amps including wiring and taking out u/s ammeter all as specified and direct.
2
-
-
Supply and fixing control cable 4core 2.5 Sqmm single strand after taking down old cable all as specified and as directed by Engr in Charge.
40
-
-
Supply and fixing control cable 10core 2.5 Sqmm single strand after taking down old cable all as specified and as directed by Engr in Charge.
40
-
-
Supply and fixing control cable 12core 2.5 Sqmm single strand after taking down old cable all as specified and as directed by Engr in Charge.
30
-
-
Supply and fixing PT fuse 11000 volts 2 Amps capacity.
2
-
-
Supply and installation of power pack unit of Input 110VAC 50 Hz ,3 phase,Out put 110, Burdan 100VA, safety devices complete suitable for existing breakers including taking down old power pack unit all as directed.(Make: Gogate electosystems Pvt Ltd/Alan electronoc systems Pvt. Ltd.)
2
-
-
M&L for fault finding of UG HT cable by portable HT fault detector (11 /33KV line) and showing the fault/short circuit distance from either end without excavating UG cable or removing cable from ground, not exeeding testing 2.5 KM running cable, complete all as specified and as directed by Engrs-In-Charge.
2
-
-
Evaluation Notes How It Works ?
Potential Partner