Military Engineer Services Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date26 Dec 2024
Closing Date16 Jan 2025
Tender Amount₹ 42,00,000
Costs
EMD
₹ 84,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Ge/alp (8408b) Kolkata Of 2024-25
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_690466_1Tender No
GE/ALP (8408B) KOLKATA OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
All as per item No. 1 here in before but capacity 125 KVA DG Set
1
-
-
... More
All as per item No. 1 here in before but capacity 79 HP Fire pump
1
-
-
... More
All as per item No. 1 here in before but capacity 110 HP Fire pump
1
-
-
... More
Supply only of Fuel filter with 'O' ring, for 320 KVA DG Set and by pass filter if required for carrying out 'B' check maintenance.
Make: Kirloskar/Kirloskar Green/BOSCH/Greaves
1
-
-
... More
All as per item No. 7 here in before but capacity 63 KVA DG Set
2
-
-
... More
All as per item No. 7 here in before but capacity 200 KVA DG Set
1
-
-
... More
All as per item No. 7 here in before but capacity 125 KVA DG Set
1
-
-
... More
All as per item No. 7 here in before but capacity 79 HP Fire pump
1
-
-
... More
All as per item No. 7 here in before but capacity 110 HP Fire pump
1
-
-
... More
Supply only of Lub Oil filter with 'O' ring, for 320 kVA DG set and by pass filter if required for carrying out 'B' check maintenance .
Make: Kirloskar/Kirloskar Green/BOSCH/Greaves
1
-
-
... More
All as per item No. 13 here in before but capacity 63 KVA DG Set
2
-
-
... More
All as per item No. 13 here in before but capacity 200 KVA DG Set
1
-
-
... More
All as per item No. 13 here in before but capacity 125 KVA DG Set
1
-
-
... More
All as per item No. 13 here in before but capacity 79 HP Fire pump
1
-
-
... More
All as per item No. 13 here in before but capacity 110 HP Fire pump
1
-
-
... More
Supply only Of Air filter for air cleaner, of 320 KVA DG set for carrying out 'B' check maintenance.
Make: Kirloskar/Kirloskar Green/BOSCH/Greaves
1
-
-
... More
All as per item No. 19 here in before but capacity 63 KVA DG Set
2
-
-
... More
All as per item No. 19 here in before but capacity 200 KVA DG Set
1
-
-
... More
All as per item No. 19 here in before but capacity 125 KVA DG Set
1
-
-
... More
All as per item No. 19 here in before but capacity 79 HP Fire pump
1
-
-
... More
All as per item No. 19 here in before but capacity 110 HP Fire pump
1
-
-
... More
Takingout worn out and Replacement of Fan Belt/dynamo Belt of suitable size as per sample.
Make: Kirloskar/Fenner/Dunlop/Kirloskar green or equivalent 63 to 320 KVA DG set.
2
-
-
... More
Takingout old unserviceable hose pipe for fuel line as per existing including replacement of adjustable hose clamps for 63 to 320 KVA DG Sets
Make: Kirloskar/Kirloskar Green/BOSCH/Greaves
2
-
-
... More
Taking out and replacement of shut down valve for the DG set of capacity 100/125/200 KVA/79Hp Dg fire Pump Make of DG Set
1
-
-
... More
M&L for cleaning of the fuel tank by emptying of the tank, replacement of fuel level indicator and spray painting of tank after scraping the existing paint , by using by Synthetic Enamel paint of two coat with matching the existing clour.
7
-
-
... More
Maintenance and servicing of alternator by removing of dust and moisture from field coil and armature coil by blowing the hot air for the various capacity of DG set capacity 63 to 320KVA DG/ 79/110 HP Fire Pump after dismantling of alternator and refitting of the same for smooth operation.
5
-
-
... More
M&L for fixing of 180AH,12 Volt lead acid battery complete all as spd and directed.
Make: Exide/Amaron TATA Green.
6
-
-
... More
M&L for copper lead for battery of 1.5 mtr long cable of two nos of red and black clour and 0.5 mtr one nos having cable size size 25 sqmm.
4
-
-
... More
M&L for filling of Distilled Water for Batttery/Radiator
100
-
-
... More
Supply only rubber hose in replacement of radiator asssembly of DG set complete all as specified and as directed
5
-
-
... More
Removing the radiator assembly of DG Set capacity upto 63/125/200 /320KVA DG /79/110 HP from its base, taken to workshop, opening into parts, carryout overhauling the complete system, sort out and replacement of the unserviceable items, cleaning the channels, fins including necessary gas welding works for arresting the leakage reassembling and refitting on its base including transportation of the same from work shop to site complete all as specified and as directed.
4
-
-
... More
S & F battery charger of charging capacity of 10 Amp 12/24 volt dually fixed in AMF panel complete with provn of necessary connection complete all as specified and as directed.
4
-
-
... More
Supply, install and commissioning of microprocessor based AMF Controller unit of 63 to 320 KVA Capacity DG Set by removing the old unserviceable control unit and testing complete all as specified and as directed by the Engr-in-Charge.
Make : C&S/L&T
Note : The faulty controller to ebe replaced with same model/make for smooth functioning.
3
-
-
... More
Supply and filling Fleet Cool HD heavy duty coolant concentrate ultimate protection for increase engine life for 200 KVA,100KVA complete all as specified and as directed. Make : Fleet guard/Castrol/Servo/HP
40
-
-
... More
Supply only engine oil of grade 20w 40 brought at sight in sealed container. Complete all as specified and as directed. Make :- Castrol /Servo/HP
150
-
-
... More
Repair/Servicing of dynamo 12/24 Volts of the DG/fire pump set by opening into parts, cleaning to sort out the unserviceable part, replace by new one, rewinding and warnishing of coil, reassembling and refixing to its base including transportation charge from work shop to the site complete all as specified and as directed.
2
-
-
... More
Repair/Servicing of self starter assembly by opening in to parts, sort out the unserviceable items like carbon bush, pinion etc and replace the same with new one including rewinding of field coils, re-assembling and refixing the same in its original position including testing for the following capacity DG Set complete all as specified and as directed.
-
-
-
... More
320/200 KVA DG Set
1
-
-
... More
125 KVA DG Set
1
-
-
... More
79/110 Hp DG Fire Pump
2
-
-
... More
Repair/Servicing to AMF Panel 320/200/125/63 KVA Capacity DG Set by dismantling unserviceable items replacing the same by new one, rewiring all internal wiring and replacing relay circuit and complete all as specified and as directed.
1
-
-
... More
Supply and fixing for Start-stop-reset push button with LED lamp including all necessary incoming and outgoing electric connections after and including taking down old unserviceable one and making good the disturbed surface complete all as specified and as directed. Make : L&T/&S/BCH/SIEMENS
8
-
-
... More
Supply and fixing for Voltmeter, single phase, class - 1, digital type after and including taking down old unserviceable one complete all as specified and as directed. Make : L&T/C&S/ELMEASURE/RISHABH
10
-
-
... More
Supply and fixing for Ammeter, single phase, class - 1, 5A digital type after and including taking down old unserviceable one complete all as specified and as directed. Make : L&T/C&S/ELMEASURE/RISHABH
10
-
-
... More
Supply and fixing for Amp meter selector switch after and including taking down old unserviceable one complete all as specified and as directed. Make : KAYCEE/L&T/SG
10
-
-
... More
Supply and fixing for Volt meter selector switch after and including taking down old unserviceable one complete all as specified and as directed. Make : KAYCEE/L&T/SG
10
-
-
... More
Supply and fixing for Current Transformer 160/5 after and including taking down old unserviceable one complete all as specified and as directed. Make : Kappa/AE /Rishabh
20
-
-
... More
Material and labour for taking down centrifugal pump from existing position, dismantling the same to carry out repair works including replacement of required spare parts, reassembling, reinstalling, checking for alignment with motor and connecting complete for following capacity of pump.
Note: Spare parts required for replacement shall be measured and paid separately.
-
-
-
... More
30/25/20/10 HP
3
-
-
... More
Supply only of following spare parts for pump set including motor complete for 25/30 HP centrifugal pump:-
-
-
-
... More
Impeller CI
4
-
-
... More
Pump shaft
4
-
-
... More
Stage bushing
4
-
-
... More
Coupling
4
-
-
... More
Bearings Make : SKF or equivalent make as approved by GE.
8
-
-
... More
Dismantling and opening the 25/30 HP motor from pump set in existing position for carrying out rewinding work with new super enamelled copper wire of suitable gauge as per existing and heat varnishing complete with all other material required for rewinding, re-assembling and refixing the same with pump in original position complete all as specified and directed.
1
-
-
... More
Same as above but for 10/15/20 HP complete all as specifed and directed.
1
-
-
... More
Labour only for lifting/ lowering of U/S submersible pump set from tube wall after disconnecting the electric supply and taking out all coloumn pipes flanged/ socket type of any length keeping serviceable fittings in safe custody for reuse, removing U/S materials from site, making good of disturbed surfaces and carrying submersible pump set to nearest repairing workshop including bring back after necessary repairs and lowering the same including all necesary fixtures like rubber gasket/nuts/bolts/washers of suitable size or welding materials for jointing cloumn pipes flanged/ socket type and connection of electric supply to motor, testing/commissioning, etc. complete all as specified and directed. Note : Replacement of Column pipes shall be measured and paid seperately.
-
-
-
... More
20/25 HP
2
-
-
... More
15/10/7.5 HP
2
-
-
... More
Material and labour for necessary repair to motor of submersible pump and taking out burnt windings, cleaning, re-winding with superior quality super enamelled copper wire of existing gauge, overhauling, refixing and testing complete for following capacity of pump.
-
-
-
... More
20/25 HP
2
-
-
... More
15/10/7.5 HP
2
-
-
... More
M & L for overhauling of submersible pump of 6 to 8 stage, 20/25HP installed at pump house with cleaning, Stage casing, Carbon trust bearing with pressure plate, Suction strainer, Diffuser Bronze, Impellers,Thrust bearing housing, Bearing segment carrier ( C.I ), Diaphragm (rubber), Stud nut and bolt 8.0 mm dia and length as per requried, Greasing,repairs to pump including replacement of spares parts like clamps, Impeller bushing, Dischrage/suction casing, Gaskets etc & connected accessories all as specified and directed.
2
-
-
... More
M & L for overhauling of submersible pump of 6 to 8 stage, 10/15HP installed at pump house with cleaning, Stage casing, Carbon trust bearing with pressure plate, Suction strainer, Diffuser Bronze, Impellers,Thrust bearing housing, Bearing segment carrier ( C.I ), Diaphragm (rubber), Stud nut and bolt 8.0 mm dia and length as per requried, Greasing,repairs to pump including replacement of spares parts like clamps, Impeller bushing, Dischrage/suction casing, Gaskets etc & connected accessories all as specified and directed.
2
-
-
... More
Material and labour for painting of 10/20/15/25/30 HP capacity centrifugal pump set after removing old painted/rusted surafce by paint removers such as blow lamps, scrapers etc over the surface of motor/pump body and giving one coat of red oxide primer and after which painting with two coat of back anticorrosive synthetic enamel paint on the surface of centrifugal pump set with electrical spray machine and letter writing by using white paint on painted surface by showing MES No & Capacity on ordered location etc complete all as specified and as directed.
4
-
-
... More
Supply and fix water proof submersible flexible flat copper cable, 10 Sqmm 3 core, 1100 Volts complete all as specified and directed. Note : Rate quoted shall be deemed to be inclusive of the cost of under water jointing arrangements complete.MAKE- Havells/Finolex/Polycab
80
-
-
... More
S &F PVC insulated Copper Cable of Size 16 Sqmm , 1100 Volt complete all as directed.MAKE- Havells/Finolex/Polycab
20
-
-
... More
S &F PVC insulated Copper Cable of Size 10 Sqmm , 1100 Volt complete allas directed.MAKE- Havells/Finolex/Polycab
20
-
-
... More
S & F PVC Insulated FRLSH flexible Copper wire 1100 Volt grade conforming to IS: 694/2010 of size 50 Sqmm complete all as directed. Make: Havells/Polycab/Finolex
50
-
-
... More
Supply and fixing in repair Fully Automatic star-delta starter of relay range 14-23 Amps, in Sheet-Steel Enclosure suitable for upto 30 HP pump including taking down of unserviceable one complete all as specified and directed. Make : L&T/BCH/TC/SIEMENS/Havells Make : L&T/BCH/TC/SIEMENS
2
-
-
... More
Supply and fixing as in repair DOL starters 3 phase 415 volts 7.5 HP 9-14 range complete all as specified and as directed.
Make : L&T/BCH/TC/SIEMENS/Havells
2
-
-
... More
Supply and fixing Three pole power contactor 63 Amps complete all as specified and directed. Make : L&T/C&S/BCH/SIEMENS/HAVELLS
2
-
-
... More
Supply and fixing Three pole power contactor 100 Amps complete all as specified and directed. Make : L&T/C&S/BCH/SIEMENS/HAVELLS
2
-
-
... More
Supply and fixing Three pole power contactor 250 Amps complete all as specified and directed. Make : L&T/C&S/BCH/SIEMENS/HAVELLS
2
-
-
... More
Supply and fixing Three pole power contactor 400 Apms complete all as specified and directed. Make : L&T/C&S/BCH/SIEMENS/HAVELLS
1
-
-
... More
Design, supply, erection, testing and commissioning of floor mounted type engine starter panel comprising of overall size not less than 400mm width x 1000mm Height x 300mm Depth, duly mounted on a M.S.Angle (40mmx40mmx5mm) long 400mm .The Panel shall be duly fabricated in an approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of panel boards and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The panel shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-42 and general construction conforming to IS : 13947. The Panel Board shall be made out of 2.00mm thick CRCA mild steel sheet and 2.00mm thick gland plate and having compartmentalized construction for individual accesores. The panel shall be comprising of the followings :- (a) oil pressure meter-01 No (Make : YANKY/MINDA)
(b) Analog type DC ammete- 01 No (Make LUCAS/MINDA)
(c) 24 volt battery charger- 01 Nos (d) 15 Amp Power socket- 01 Nos (Make : Anchor/Gold Medal/Protam)
(e) water temprature meter- 01 Nos (Yanday/Minda)
(f) Engine start/Stop Key- 01 Nos (Make : LUCAS/MINDA)
1
-
-
... More
Note : All the above mentioned items shall have to be integrated with the engine , battery etc for smooth functioning all as specified and as directed.
-
-
-
... More
Supply, erection, testing and commissioning of wall mounted power distribution pael of size 700mm (W)x500mm (H)x200mm (D) made of 2.00 mm CRCA MS Sheet duly painted with SIEMENS GRAY Colour powder coated paint (RAL7032) and consisting of the following :-
(a) TPN MCB 40A -01 No (Make : L&T/LEGRAND/ABB)
(b) SPN MB 20A-04 Nos (Make : L&T/LEGRAND/ABB)
(c) LED Indicator lampy (R-Y-B)-01 Set (Set of 3 lamps) (d) Aluminium Bus Bar 25mmx4mm -04 Nos
Location : P6/01 & P6/02 HQ BSA
1
-
-
... More
Supply, erection, testing and commissioning of outdoor LT Feeder Pillar box of overall dimension 1200 mm (H) without canopyxx900mm (W)x450mm (D) havind double layered front door and single layered rear door made with 3.0mm thick CRCA MS sheet duly painted with powder coated paint (RAL7032) and MS Channel (75MC) base frame having all cable entry/exit through bottom and consisting of the following :-
(a) ON load 200A 4 pole,415V Change Over Switch having front operated handle (Open execution type -01 No (Make : L&T/Havells/HPL)
(b) MCCB 200A, 4 Pole , 25KA with adjustable thermal and adjustable magnetic release -01 No (Make : LEGRAND/ABB/L&T)
(c) LED Indicator lampy 22mm (R-Y-B)- 01 Set (Set of 3 lamps) (d) MCB SP 6A, 10KA breaking capacity-06 Nos
1
-
-
... More
Supply and laying for under ground heavy duty XLPE insulated, armoured aluminium conductor cable 1100 volts grade, cross-sectional area 240 sqmm 3.5 Core core in trenches / through pipe in road crossing / plinth/ drain/ duct/ floor along pole / wall /ceillings etc complete all as specified and directed.
Make :Havells/KEI/Polycab/Finolex Note:- Earth work, bricks protection, sand cushioning shall be measured and paid seperately.
100
-
-
... More
All as per Item no 71 here in before but 400 sqmm 3.5 core
50
-
-
... More
All as per Item no 71 here in before but 120 sqmm 3.5 core
150
-
-
... More
All as per Item no 71 here in before but 150 sqmm 3.5 core
100
-
-
... More
All as per Item no 71 here in before but 25 sqmm 4.0 core
100
-
-
... More
S&F perforated GI Cable tray of size 450 mm (1.2mm thick)x 75 mm depth with cover to be fixed on wall or hanging with mounting bracket or hanging from ceiling with down rod etc, and all as directed.
100
-
-
... More
S&F perforated GI Cable tray of size 300 mm (1.2mm thick)x 75 mm depth with cover to be fixed on wall or hanging with mounting bracket or hanging from ceiling with down rod etc, and all as directed.
80
-
-
... More
S&F perforated GI Cable tray of size 200 mm (1.2mm thick)x 50 mm depth with cover to be fixed on wall or hanging with mounting bracket or hanging from ceiling with down rod etc, and all as directed.
50
-
-
... More
S&F perforated GI Cable tray of size 100 mm (1.2mm thick)x 50 mm depth with cover to be fixed on wall or hanging with mounting bracket or hanging from ceiling with down rod etc, and all as directed.
25
-
-
... More
Maintenance / servicing of APFC panel of capacity upto 700 KVA ,415 V -50/60 Hz -50kA for auto correction of power factor . complete checking of each capacitor bank, connector and MCB . Cleaning and servicing of all fixed and moving contacts replacement of accessories i.e lockable trip push button,auto /manual switch, indicator , volt meter, ammeter etc after disconneting the APFC for execution of work and re-fixing the same shall be with old serviceable spare parts in existing position and re-connecting all cables and testing on existing load complete all as specified and as directed.
Make:- L&T or other equivalent make as approved by GE.
Note: Cost of all new spare parts except APFC Relay, Power capacitor and power Contactor as required shall be deemed to be included in the unit rate.
4
-
-
... More
Supply and fix power capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 2 KVAR capacity. Make : L& T/Neptune/EPCOS/BCH
4
-
-
... More
Supply and fix power capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 3 KVAR capacity. Make : L& T/Neptune/EPCOS/BCH
5
-
-
... More
Supply and fix power capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 5 KVAR capacity. Make : L& T/Neptune/EPCOS/BCH
4
-
-
... More
Supply and fix power capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 10 KVAR capacity. Make : L& T/Neptune/EPCOS/BCH
4
-
-
... More
Supply and fix power capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 20 KVAR capacity. Make : L& T/Neptune/EPCOS/BCH
4
-
-
... More
Supply and fix power capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 25 KVAR capacity. Make : L& T/Neptune/EPCOS/BCH
4
-
-
... More
Supply and fix capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 50 KVAR capacity. Make : L& T/Neptune/EPCOS/BCH
2
-
-
... More
Supply and fix MOC 25 contactor . Make :- L&T or equivalent make as approved by GE.
4
-
-
... More
Supply and fix LED indication lamps complete . Make :- L&T or equivalent make as approved by GE.
10
-
-
... More
Supply and fix MCB 40- 63 Amp three pole 10 KA 'C' Series. Make :- L&T/C&S/LEGRAND/HAVELLS
6
-
-
... More
Maintenance / servicing of LT ACB upto1000A Capaxirty,415 V -50/60 Hz,Icu-50 kA Ics-50 KA,Icw-50kA for 1 second of make L & T with Cleaning and servicing of all fixed and moving contacts replacement of accessories i.e lockable trip push button, LIP, LAP, racking, interlock, door interlock, shunt release, under voltage release(UVR) etc after disconneting the ACB for execution of work and re-fixing the same shall be with old serviceable spare parts in existing position and re-connecting all cables and testing on existing load complete all as specified and as directed.
4
-
-
... More
Supply and fix on load change over switch 400 Amps 415 Volt 4 pole after and including taking down old unservoceable one complete all as specified and as directed. Make : L&T/Havells/C&S/LEGRAND
3
-
-
... More
Supply and fix on load change over switch .320 Amps 415 Volt 4 pole after and including taking down old unservoceable one complete all as specified and as directed. Make : L&T/Havells/C&S/LEGRAND
2
-
-
... More
Supply and fix on load change over switch 250 Amps 415 Volt 4 pole after and including taking down old unservoceable one complete all as specified and as directed. Make : L&T/Havells/C&S/LEGRAND
3
-
-
... More
Excavating in trenches, n exc1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc1.5 m in depth and getting out Complete all as directed.
25
-
-
... More
Returning, filling in trenches including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
12
-
-
... More
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level , not exceeding 1.5 metre above the starting point complete all as specified and as directed.
13
-
-
... More
Cutting of bitumenous road including top layer, WBM, Soil/concreate surface for laying of cable protection pipe, water pipe etc and making good of disturbed surface with PCC 1:2:4 type to match with the surroundings complete all as specified and directed:
50
-
-
... More
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to desired thickness complete all as specified and as directed.
2
-
-
... More
Supply and laying for burnt brick sub class 'B' of size (25 X 12.5 X 7.5) cm locally available best quality laid in trenches for protections of under ground cable complete all as specified and as directed.
3500
-
-
... More
Supplying and laying UPVC pipes (SCH-80) having 150mm internal dia including all jointiing materials complete all as specified and directed.
50
-
-
... More
S & F LED bollard light fitting 9/10 watt 230V, AC outdoor type with IP 65 protection with excellent light output complete all as spd and directed. Make : Crompton Cat part No LBLA1-10CDL/Surya Cat No SLE8L-10W-GLZ 600NX/Bajaj Cat No BGBOL 605 9W LED WH)
25
-
-
... More
Materials and labour for plain cement concreate (1:4:8) type D2 (using 40 mm gradeed stone aggregrate) as in foundations filling, coping for pole and mass concreate complete all as specified and as directed.
0.5
-
-
... More
M&L for Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) and all as directed.
3
-
-
... More
Materials and labour for plain cement concreate (1:3:6) type C2 (using 40 mm graded stone aggregrate) as in foundations filling, coping for pole and mass concreate complete all as specified and as directed.
2
-
-
... More
Materials and labour for plain cement concreate (1:3:6) type C2 (using 40 mm gradeed stone aggregrate) as in foundations filling, coping for pole and mass concreate complete all as specified and as directed.
2
-
-
... More
Excavating in post holes (orsimilar holes) each n exc 0.5cu. m, getting out, returning,filling in and ramming earthor broken rubblemixed witheartharound, in layers notexceeding 25 cm, Complete all as directed.
10
-
-
... More
S & F M.S. Fabrication work consisting of wire mesh, M.S. Angle squire pipe, Flate etcFe-410-W(Gde-E-250) duly cut into shape and size to fabricate the shape as specified and as directed by Engr-in-charge including grouting on wall, floorcetc and one coat of red oxide meteal primar and two coats of synthetic enamel paint.
600
-
-
... More
Supply only Chain link MS galvanisd fencing, any size or type Complete all as directed.
200
-
-
... More
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire Complete all as directed.
80
-
-
... More
M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long Complete all as directed.
30
-
-
... More
M&L for Steel work in 100 mm tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240
200
-
-
... More
M&L for Framed work as in doors or gates of angle or other sectionwith gusset plates, rails,braces, etc., complete, drilled forfixing of steel sheeting or othercovering. Doors, etc. to beprepared for hanging or slidingwithandincluding either hooks and hinges or steel hangingdoor fittings (exclusive of steels heeting or other covering, running rails and guides) and hanging; also fastening
200
-
-
... More
M&L for Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out
120
-
-
... More
M&L for welded steel wire fabric complete to be fixed on steel structure complete all as specified and as directed.
150
-
-
... More
M& L for Mild steel bars 6mm to 8 mm dia and over, cut to length, bent to shape required, including cranking, bendin spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
50
-
-
... More
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size (32 x 6) mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded stone aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed
10
-
-
... More
Supply and fixing for single aluminium strip of size (25x3.15) mm in proper position with saddles and fixing screws for roof conductors and down conductors from top of the building air termination point to the test point of the building of height G+1 to G+12 as required after and including taking down of the old unserviceable one and making good the disturbed surface complete all as specified and as directed.
170
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%