Military Engineer Services Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Building Construction
Eprocure
Opening Date9 May 2024
Closing Date12 Jun 2024
Tender Amount₹ 43,60,000
Costs
EMD
₹ 87,200Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_653032_1Bid Award Id
ViewTender No
8012/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L providing sand cushioning with a layer of clean, dry, fine sand for protection of electric cable laid in trenches/ducts, punned down to desired thickness complete all as specified and directed.
(Note: For payment purposes only punned down thickness of sand shall be measured )
5.1
-
-
M & L for laying old size sub class ‘B’ brick for PVC/ XLPE under ground cable protection in trench, layed in the manner that width of brick to be peperndicular to the axis of cable , over LT under ground cable complete all as specified and directed.
0.53
-
-
Supplying, Laying connecting & testing XLPE insulated, PVC sheathed, heavy duty armoured LT under ground cable of size 25 Sqmm, 4 core 1100 V grade PVC insulated ,multi stranded aluminium cable in pipe /trench /cable duct /fixed on wall by proper size shaped GI clamps with nut bolts etc including lugs for both ends and making good the disturbed surfaces complete all as specified and directed.
90
-
-
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
832.19
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not
backing), removing serviceable tiles and rubbish off the premises complete all as directed.
529.26
-
-
Taking down and refixing the aluminium/copper earthing strips in same position with and including all new fittings and fixtures complete all as specified and as directed.
75
-
-
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed (unit rate shall be inclusive of demolition of cement concrete blocks for embedding hold fasts complete.)
14
-
-
Taking down chowkats of frames wth shutters (without taking out off shutters from the frame) exc 1.5 sqm and n exc 4.00 sqm each including hold fasts and removing the same from site complete all as specified and as directed. (unit rate shall be inclusive of demolition of cement concrete blocks for embedding hold fasts complete.)
12
-
-
Dismantling of wall/ ceiling boards(fibre pulp insulation etc.) or insulations boards /slabs/blankets any thickness including cover fillets of any description including all snap grids and hanging arrangements complete all as specified.
210
-
-
Demolition of cement concrete of any description and in any position and removing unserviceable material exc 1500 mtr out side of MOD land complete all as directed as specified.
8.05
-
-
S&F aluminium anodised frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
93.72
-
-
S&F aluminium anodised door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
10
-
-
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
2.02
-
-
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer- in-charge.
1.5
-
-
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge.
150
-
-
S&F miniumum thickness 46mm thick Steel door shutter of 120 minutes fire rated confirming to IS:3614 Part-II and BS-476, Part 20-22. Prototype certified from Govt. approved lab CBRI Roorkee. Fabricated with 2 Nos 1.20 mm thick galvanized steel sheet infill with Rockwool suitable for 120 minutes. including Door frame manufactured with 1.60 mm thick galvanized steel sheet pressed to form single rebate profile size 100x58 mm with and fixing dash fastener of approved size. The frame shall be infill with rockwool. The frame and shutter finished ith powder coating of approved RAL shade. The frame and door shutter shall have the following included:
Size of steel door with frame : 1200 x 2100 mm
Fire Rating : 120 minutes
Door Closer TS1500C with Hold Open Arm - 1 No
D Handle 300 x 19 - 1 No
Mortise Dead Lock with both side key - 1 No
SS 304 2BB Fire Rated Hinge 4"x3"x3mm - 4 Nos
Vision Panel 200 x 300 mm
5
-
-
S&F Roof trusses (framed) trussed, purline crane gantries ,rails and fastenings and heavy brackeet framing (Beam,tee,angle, channel or flat sections) including distance pieces ,cleats etc Fe-410-W (Gde-E-250)quality-A complete all as specified and as directed.
339.3
-
-
Supply & Fixing for rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with out any attachment conforming to Fe:410-W(Gde-E-250 ) quality-A complete all as specified and directed.
832.37
-
-
M & L for ceramic fully vitrified tiles, coloured ceramic floor tiles (group B IIa), 600 mm X 600 mm X 9-10 mm in floors laid over 20 mm thick screed bed or bedding layer in cement mortar(1:4) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and directed.
235.65
-
-
M & L for ceramic fully vitrified tiles, coloured ceramic floor tiles (group B IIa), 600 mm X 600 mm X 9-10 mm in skirting's/ vertical surfaces laid over 10 mm thick backing coat in cement mortar(1:3) set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed.
23.57
-
-
Materials and Labour for, Digital glazed ceramic printed coloured tiles, 350 X 250 X 7-8mm thick, conforming to IS 15622, Grade B III, on vertical surface of wall such as dados,skirting etc, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick screed bed or bedding layer of cement mortar (1:3), complete all as specified and directed.
270.05
-
-
Materials and Labour for for 25 mm thick plain cement concrete (1:2:4) type B1 using 20 mm graded aggregate as in sub base floor/paving/hardstanding complete all as specified and directed.
41.86
-
-
M & L 75 mm thick plain cement concrete M15(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as hadstanding/subase complete all as specified and as directed.
50
-
-
M & L 100 mm thick plain cement concrete M15(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and rough as as in sub base floor/paving/hardstanding complete all as specified and directed.
41.86
-
-
Taking out of old damaged unserviceable tarfelt or membrane of any description including screed bed or bedding layer and removing of debris from premises and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete to receive roof treatment all as specified and as directed.
280
-
-
M&L for 30 mm thick (Average) cement concrete type B-0, 1:2:4 using 12.5 mm graded aggregate as in roof padding, levelling course or similar work in order to maintain proper slope and camber finished the surface fair and even complete all as specified and as directed.
8.4
-
-
M & L for 10 mm thick screed bed or bedding layer in cement mortar 1:4 (to be laid when concrete is still green) with water proofing compound for roof as per Manu-factuerer’s Instructions, complete including ponding test for 72 Hrs all as specified and as directed. (Note : WPC will be measured and paid separately)
280
-
-
M & L for one coat of cold bitiminous primer (IS 3384) @ 0.25 Ltr/sqm apply evenly including cleaning of surfaces complete all as specified and direcetd
280
-
-
M&L for laying APP based polymeric membrane minimum weighing 3.5Kg/sqm and mimimum 3mm thick reinforced with polyster non woven fabric (weighing. not less than 160 gms/sqm) laid on primed surface by torch application complete all as specified and direcetd. The overlaps shall be minimum 100 mm on the transverse direction and 75mm on longitudinal direction.
280
-
-
Materials and Labour for rendering 15 mm thick, cement plaster, in cement mortar (1:4) on surface fair face of brickwork in walls and finishing surface even and smooth without using extra cement, complete all as specified and directed.
261.07
-
-
Materials and Labour for rendering 5 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed. Note: - Note : Water proofing compound will be measured and paid separately
303.15
-
-
Supply only Liquid water proofing compound conforming to IS: 2645 - 2003 specification complete all as specified and as directed.
9.87
-
-
S&F of Anodised aluminium snap grid frame work of size 605 mm x 605mm for false ceiling all as specified
210
-
-
S&F of Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
210
-
-
S&F of Non asbestos fibre cement building boards 4 mm thick, fixed or inserted to Aluminium framework as in false ceiling, with screws complete all as specified.
210
-
-
M & L pre-painted hot-dip aluminium-zinc alloy metallic coated any approved profile steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
1.13
-
-
M & L pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
1
-
-
M&L for preparation of newly plastered surfaces of walls, and applying two coats acrylic distemper on wall ,over and including with a coat of 1.5 mm thick white wall care putty premium quality over and including a coat of primer new plastered or unplastered surfaces on wall, complete all as specified and as directed.
261.07
-
-
S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed.
5
-
-
M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other wall features etc by brooming down or steel wire brushing/sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat acrylic distemper on old surfaces complete all as specified.
350
-
-
M & L for applying Two 100 % Acrylic Exterior Emulsion paint in camouflage pattern (Three colours as approved by GE) over a coat of exterior wall primer on new concrete/wall surfaces up to 18 Mtr height including all necessary scaffolding and safety measures complete all as specified and directed.
303.15
-
-
Material and Labour for complete removal of existing treatment and applying two coat of100 % Acrylic Exterior Emulsion paint in camouflage pattern (Three colours) painting over and including a coat of primer to old plastered or unplastered surfaces on walls including preparation of surfaces, up to 18 Mtr height including all necessary scaffolding and safety measures complete all as specified and directed.
300
-
-
Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge
48.11
-
-
S & F in repair exposed type hydraulically regulated door closers, universal closer, bottle type (type A), Designation No. 3, suitable for 61 kg to 80 kg mass of doors & 851 mm to 1000 mm width of door, aluminium alloy non porous body and black plate, aluminium alloy piston or pack piston/ pillion, anodized finish not be less than Grade AC 15 of IS 1868 : 1996 with transparent anodic film as per IS 3564: 1995 complete all as specified and as directed.
5
-
-
S & F in repair brass 4-levers Mortice lock, vertical type, size 100mm coplete all as specified and directed.
5
-
-
Supply and Fix,4.8mm thick tinted glass of superior quality fixed to aluminium frame works with rubber beadings n.exc 0.5 sqm of each pane complete all as specified and directed.
10
-
-
Supply and Fix,4.8mm thick tinted glass of superior quality fixed to aluminium frame works with rubber beadings exc 0.5 sqm of each pane complete all as specified and directed.
13
-
-
M&L Brick work with flyash bricks old size bricks, straight or curved on plan exc. 6m mean radius built in cement mortar 1:4 all as specified
1.63
-
-
Taking down carefully (copper/aluminium) point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants regulators sub main wiring, light fittings etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
153
-
-
Taking down unserviceable submain wiring alongwith batten /PVC conduits or etc and making good disturbed surfaces of walls/floors and match the existing surface all as directed at site.
80
-
-
Taking down unserviceable main switches, DBs / changeover switch alongwith Teak wood boards etc including MCBs/isolators and making good the disturbed surfaces of wall / floors to match the existing surface all as directed at site
5
-
-
M & L for concealed point wiring complete with 1.5 sq mm FRLS,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red/yellow/blue wires for phases and black wire for neutral),drawn into and including non metalic PVC rigid conduit medium grade of suitable size and conduit accessories fixed on wall, floor, roof etc. and including provision of PVC FRLS insulated 1.5 sq mm copper conductor for earth continuity (Green Colour) and connected to common earth dolly including sunken in GI terminal box 2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets for the following:-
Note : a) Note :- Cost of PVC conduit, cutting chases of wal/ceilingl, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.
-
-
-
(a) One light/fan/ call bell point controlled by one switch.
62
-
-
(b) One 3 pin socket outlet 5 Amps on independent board.
22
-
-
All as per Item No. 48.00 here-in-before but with FRLSH grade, (ISI mark) PVC insulated and unsheathed two run multistranded copper conductor of size 2.5 Sqmm for one power point of 3 pin 15 Amps on independent board including FRLSH grade (ISI mark), PVC insulated, unsheathed one run multi-stranded copper conductor of size 2.5 sqmm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.
69
-
-
S & F Switch of Socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal all as specified and directed.
69
-
-
S & F Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal all as specified and directed.
22
-
-
S & F switch piano flush button single pole one way 5 amp 240 volts, all as specified and as directed.
62
-
-
M & L for ceiling rose, surface bakelite, 65 x 50 mm, three terminals all as specified and as directed.
34
-
-
Supply and fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
1
-
-
S&F LED 20 Watt tube light fitting intregated type, including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 extruded aluminium LED battens life span of minimum 25000 working hours complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed. . Note : Make of batten and LED tube lamp should be of same make.
29
-
-
Taking down existing panel light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 36 watt recess mounting of size 600 mm x 600 mm , LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 25000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core complete all as specified and directed by EIC.
27
-
-
S&F sheet metal enclosure 20 Amps single pole and natural with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB 20 Amp fixed properly in concealed position including making good disturbed surface all as directed by Engineer-in-charge.
6
-
-
Supply & fixing ON-Load Changeover switch, 4 Pole, 415 volt, 50Hz, 315 Amp including SS enclosure complete all as specified and as directed.
1
-
-
Supply & fixing DB Box, in sheet metal enclosure Vertical type double door VT DB TPN, MCCB DB TPN 6 way, with and including 250 Amp,36 KA,TP MCCB as incomer ,( 250 Amps, TP, 36 kA MCCB rate inclusive) and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, with 100 Amp copper bus bar for each phase, with 2 Neutral bar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, including flushing and fixing DB box in neaty in wall complete all as specified and directed by Engr-in-charge.
Note : DB and switchgear shall be of same make.
1
-
-
Supply & fixing DB Box, in sheet metal enclosure VT DB TPN, MCCB DB TPN 4 way, double door with and including 100 Amp, 25 KA,TP MCCB as incomer (100 Amps, TP, 25 kA MCCB rate inclusive) and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, with 100 Amp copper bus bar for each phase, with 2 Neutral bar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, including flushing and fixing DB box in neaty in wall complete all as specified and directed by Engr-in-charge. Note : DB and switchgear shall be of same make.
1
-
-
Supply & fixing DB Box, in sheet metal enclosure VT DB TPN, MCCB DB TPN 4 way, double door with and including 63 Amp, 16 KA,TP MCCB as incomer ( 63 Amps, TP, 25 kA MCCB rate inclusive) and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, with 100 Amp copper bus bar for each phase, with 2 Neutralbar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, including flushing and fixing DB box in neaty in wall complete all as specified and directed by Engr-in-charge. Note : DB and switchgear shall be of same make.
1
-
-
Supply and fixing MCB DB double door TPN 4 way IP 43 IK 9 protection with sheet metal enclosure with isolated neutral bus bar DB suitable for Door earthing, insulated copper busbar assembly for mounting MCB SP / TP.
1
-
-
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 , IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge.
6
-
-
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, Ik09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed .
2
-
-
S & F MCB, TP , 100 Amps, 16 KA, C curve breaking capacity including connection with suitable size copper lugs complete all as specified.
5
-
-
S & F MCB, TP , 40-63 Amps, 10 KA, C curve breaking capacity including connection with suitable size copper lugs complete all as specified.
10
-
-
S & F MCB, TPN/FP , 50-63 Amps, 10 KA, C curve breaking capacity including connection with suitable size copper lugs complete all as specified.
2
-
-
S & F MCB, SPN , 40 Amps, 10 KA, C curve breaking capacity including connection with suitable size copper lugs complete all as specified.
8
-
-
& F MCB, SPN , 6-32 Amps, 10 KA, C curve breaking capacity including connection with suitable size copper lugs complete all as specified.
54
-
-
Supply & fixing in repair Surge protection device Type 1 + 2 maximum dischare current I(max) 50KA, I(imp) 12.5 KA, 1P+N (1 Pole & Nuetral) including installation in parallel connection in DB and making all electrical connections with 4 x 6.0 Sqmm single core copper wire with copper lugs complete all as specified and directed by Engineer in charge.
4
-
-
Supply & fixing in repair PVC conduit of 25 mm dia inclusive of boxes (junction/ terminals) all tees, bends, elobows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock nuts, saddles , pipe hook etc to be fixed on surface for telephone/communication cable wiring in neat presentable condition including taking down old u/s and drawn cable through conduit complete all as specified and directed by Engineer in charge.
60
-
-
Supply and fixing for concealed type sub main wiring with two run of 4.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including through Rigid non-metallic PVC conduit(medium) ISI marked of size 25mm bore with all fittings like tee/Bend/Elbow/Reducer/Bell mouth/Junction / Terminal Boxes etc. and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc. of nominal size 25 mm including one run of 4.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified. Note : (i) Note : 2 runs of line conductor, one run of earth continuity conductor, one run of PVC conduit and one run of cuttinf chases shall be measured as unit length. (ii) Cost of PVC conduit, conductors, cutting chases of wall, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.
90
-
-
Supply and fixing for concealed type sub main wiring with two run of 6.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including through Rigid non-metallic PVC conduit(medium) ISI marked of size 25mm bore with all fittings like tee/Bend/Elbow/Reducer/Bell mouth/Junction / Terminal Boxes etc. and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc. of nominal size 25 mm including one run of 6.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified. Note : (i) Note : 2 runs of line conductor, one run of earth continuity conductor, one run of PVC conduit and one run of cuttinf chases shall be measured as unit length. (ii) Cost of PVC conduit, conductors, cutting chases of wall, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.
36
-
-
Supply & fixing LED building security light fitting 35 watt 230 volt AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
4
-
-
Supply and fixing heavy duty wall mounted fan 300 mm sweep 1280 rpm, 230 V 50 Hz plastic body with self opening louvers including all mounting accessories and making connections using three core copper conductor cable connected from ceiling rose to fan and marking MES No in black paint and making hole / opening of suitable size in existing wall and making good in cement mortar 1:4, and matched with existing surface complete all as specified and as directed.
1
-
-
Supply & fixing in repair AC diffuser 150 mm x 150mm four way powder coated standard finish RAL9016 square type, made up of matel body including necessary fixing arrangement and cutting , fixing work complete all as specified and directed by Engineer-in-charge .
18
-
-
Material and labour for closing/covering AC duct of GI sheet, of existing size/gauge with new CRCA sheet of existing size/gauge , fabrication work, including welding , cutting , fixing work as required at site complete all as specified and directed by Engineer-in-charge
20
-
-
Taking down carefully old serviceabe split AC of any capacity from its existing/original position incl its electrical connection including its complete servicing, charging of gas ,testing and then refixing the same in its original position complete all as specified and directed .
6
-
-
Material and labour for fixing raceway cable tray without cover made of pre galvanised GI (GP sheet) of size 100 x 40 x 40 mm with minimum thickness 18 SWG with all necessary fixing arrangement complete all as specified and directed by Engineer-in-charge
45
-
-
Taking down carefully old serviceable copper strip of any size and then refixing the same by providing new procelain insulator or drawn in conduit including PVC conduit fixing arrangement with wallcomplate all as specified and directed by Engineer-in-charge .
42
-
-
Material and labour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mm mm buried directly in ground (Earth pit not less than 2.25m below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI wire 4 mm dia as earth lead by means of bolt, nuts, check nuts and washers of galvanised iron or steel, upto 7.5m length, earth strip protected by and including 20 mm dia GI pipe (light grade) and connected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC (1:3:6) type C1 , Precast RCC (1:2:4) Type B1 cover slab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100 mm C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm bore GI Pipe (Medium Grade) for watering, Charcoal and salt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any type of soil and disposal of spoil to a distance n.exc 50 m and necessary testing complete all as shown in Electrical Plate No 3 of SSR Part-I. NOTE : 1. The unit rare includes for protectionh GI pipe of 20mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI wire of 4mm dia from top of earth plate upto 7.5 meter above/below ground level is deemed to be included in the unit rate. 4. All the joints in GI strip and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate
3
-
-
Taking down carefully old fire alarm panel -01 No, smoke detector 49 Nos, MCP -06 Nos, thermal dector -12 Nos, , Sounder -01 No, Loud speaker - 01 No, and connected acessories , complete, at AFNET site-I , (fittings such as speakers, wiring etc, and refixing the serviceable items in existing location in fully serviceable condition complete with including Comprenesive maintenance through hrough Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed Note : (i) All serviceable items shall be reused and fixing rate shall deemed to be included in the unit quoted rate .(ii) Rate is also included for testing and commissioning .
1
-
-
Supply and fix Fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules1413 complete as per OEM specification all as specified and directed by Engineer-in-charge . Make : As per existing
1
-
-
Supply and fix thermal detector complete as per OEM specification all as specified and directed by Engineer-in-charge Make : As per existing
10
-
-
Supply and fix smoke detector complete as per OEM specification all as specified and directed by Engineer-in-charge , Make : As per existing
37
-
-
Supply and fix detector base complete as per OEM specification all as specified and directed by Engineer-in-charge ,Make : As per existing
49
-
-
Supply and fix Addressable manual call point break glass type with alarm LED complete as per OEM specification all as specified and directed by Engineer-in-charge
4
-
-
Supply and fix GSM auto dialer unit for communication purpose with suitable complete as per OEM specification all as specified and directed by Engineer-in-charge
1
-
-
Supply and fix Hooter as per OEM specification complete all as specified and directed.
5
-
-
Supply only of 12 V, 7 AH battery as per OEM specification back up to all FACP and RTU panell complete all as specified and directed.
4
-
-
Supply and lay PVC insulated 2 core 1.5 sqmm PVC sheathed multi strand copper conductor for fire alarm complete all as specified and directed.
230
-
-
Supply & fix Rigid steel conduit Stove enamelled, black of size 25mm dia complete all as specified and directed.
230
-
-
Labour only for connection ,testing and commissioning all spares of fire alram system including submission of layout plan of fire alram system of entire AFNET site-I building complete all as specified and directed.
1
-
-
Evaluation Notes How It Works ?