Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date10 Feb 2025
Closing Date24 Feb 2025
Tender Amount₹ 40,37,400
Costs
EMD
₹ 80,740Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Ge/alp (8338b) Kolkata Of 2024-25
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_673478_2Tender No
GE/ALP (8338B) KOLKATA OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Demolition of reinforced Concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition)
3
-
-
... More
M&L for Reinforced cement concrete (nominal mix) Type B1 (1:2:4) (20mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span
3
-
-
... More
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc
30
-
-
... More
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
300
-
-
... More
All as per item No 7 here in before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
80
-
-
... More
Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water complete all as specified and as directed.
220
-
-
... More
M&L for Rendering 20 mm thick in two layers (Top 10mm thick rendering coat mixed with water proofing compound shall be laid over 10mm thcik plastered surface) with CM (1:4) on of brick work or concrete surfaces finished the surface even and smooth without using extra cement to match the existing surface complete in all respect as specified and directed.
Note: WPC shall be measured and paid separately
120
-
-
... More
M&L for Rendering 15 mm thick in CM (1:6) on other than fair face of brick work or concrete surfaces and finished the surface fair & even without using extra cement to match the existing surface all complete all as specified and directed.
80
-
-
... More
M&L for Rendering on ceiling 5 mm thick in cement mortar (1:3) on of concrete surface finished even and smooth with out using extra cement complete all as specified and directed.
20
-
-
... More
Supply only Integral water proofing compound complete in all respect as specified and directed.
15
-
-
... More
Taking down of Chowkhat with shutter (without taking of shutter) area exc 1.5 Sqm but not exc 4.0 sqm complete all as specified and directed.
8
-
-
... More
Taking down of Chowkhat with shutter (without taking of shutter) area n. exc 1.5 Sqm complete all as specified and directed.
8
-
-
... More
S & F 2nd HW plain solid straight chowkhats,wrought framed rebated on the solid,rounded or chamfered put together with glue pinned at joints.
0.5
-
-
... More
M&L for 30 mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specificed and directed.
25
-
-
... More
M&L for cement concrete type B0 (1:2:4) 12.5 mm graded stone aggregate as in hold fast block kerbs or mud stops, rounded or chamfered etc comlete all as specified and directed.
0.5
-
-
... More
S&F for Factory made single extruded WPC(Wood polymer composite) solid door Frames of size 45 x 70mm comprising of virgin PVC polymer of K value 58-60(Suspension grade), calcium carbonate & natural fibres and non-toxic additives fabricated with mitre joints after applying PVC solvent cement and screwd with full body threaded star headed SS screws having minimum frame density of 750 Kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), mimimum compressive strength of 58 N/Sqmm and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof & fire retardant & fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as directed.
20
-
-
... More
S&F for Factory made single extruded WPC(Wood polymer composite) solid flush door shutter of 30mm size comprising of virgin PVC polymer of K value 58-60(Suspension grade), calcium carbonate & natural fibres and non-toxic additives fabricated with mitre joints after applying PVC solvent cement and screwd with full body threaded star headed SS screws having minimum density of 650 Kg/cum, screw withdrawal strength of 1800 N(Face) & 900 N (Edge), mimimum compressive strength of 50 N/Sqmm, modulas of elasticity 850 N/sqmm & resistance to spread of flame of class A category with property of termite/borer proof , water/moisture proof & fire retardant & fixing with SS butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per directed.
8
-
-
... More
S&F Anodised powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators etc with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
100
-
-
... More
S&F for Anodised aluminium powder coated door, windows, ventilators shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed.
5
-
-
... More
S&F 4.8 mm thick Sheet glass, ordinary quality and glazing in square n.exc 0.5 sq. m in each pane fixed to aluminium frame work complete all as specified and as directed.
10
-
-
... More
S&F Extruded aluminium alloy handles 75mm long, fabricated type,anodised complete all as specified and as directed.
5
-
-
... More
S&F Extruded aluminium alloy handles 150 mm long, fabricated type,anodised complete all as specified and as directed.
5
-
-
... More
S&F 300mm long sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bots and sliding bolts of extruded or cast aluminium alloy complete all as specified & as directed.
5
-
-
... More
S&FAluminium anodised barrel tower bolts of extruded section with 150 mm long bolt, all as specified .
5
-
-
... More
S&F Hinges 125 mm, cast brass, with mild steel hinge pin, bright polished and fixed medium wheight , complete all as specified and directed.
24
-
-
... More
S&F 2nd class hardwood Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles n exc 200 cu. cm each complete in complete in all respect as specified and directed.
10
-
-
... More
S&F for Stainless steel wire cloth having 0.36 mm nominal dia of wire and average width of appreature 1.40 mm and fixed with stainless wire staples complete all as specified & as directed.
15
-
-
... More
S&F floor door stopper overall length of cover plate 150mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified & as directed.
10
-
-
... More
Dismantling of stone slabs and tiles of any description or thickness in floors,aprons etc laid, bedded and pointed in any mortar complete in all respect as specified and directed.
11
-
-
... More
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, including over 20 mm thick screed bed in CM (1:6) all as specified and directed.
110
-
-
... More
M&L for 25mm thick PCC (1:2:4) type 'B-0' using 12.5 mm graded crushed stone aggregate as in sub base complete all as specified and directed.
110
-
-
... More
Dismantiling of floor hearth or wall tiles incl cement mortar (but not backing), and rubbish off the premises (out of MOD land), complete all as specified and directed.
185
-
-
... More
M&L non-skid joint free ceramic (coloured) tiles 7-8mm thick area of each tiles exeeding 0.18sqm but n.exceeding 0.38 sqm in floor etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified & as directed. Note: Screed bed shall be measured and paid separately
40
-
-
... More
M&L non-skid joint free ceramic (coloured) tiles 7-8mm thick area of each tiles exeeding 0.18sqm but n.exceeding 0.38 sqm in skirting etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified & as directed. Note: Screed bed shall be measured and paid separately
15
-
-
... More
M&L non-skid joint free ceramic (coloured) tiles 7-8mm thick area of each tiles exeeding 0.06sqm but n.exceeding 0.11 sqm in toilet/bath floor etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified & as directed.
Note: Screed bed shall be measured and paid separately
30
-
-
... More
M&L for glazed ceramic (coloured) tiles of size 450x350 6-7mm thick as in vertical surface/dado set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
100
-
-
... More
M&L Screed bed or bedding layer 15 mm thick in cement mortar (1:6) for laying floor finishes complete all as specified and directed.
70
-
-
... More
M&L backing coat/Screed bed or bedding layer of mortar 10 mm thick in cement mortar (1:4) as in dado/skirting complete in all respect as specified and directed.
115
-
-
... More
Taking up or down 15mm bore steel water tubing and connections,including cleaning for removal to store(GI Pipe) complete all as specified and as directed.
100
-
-
... More
Taking up or down 20mm bore steel water tubing and connections,including cleaning for removal to store(GI Pipe) complete all as specified and as directed.
20
-
-
... More
S&F CPVC pipes 16 mm outer diameter of SDR 11 & plain CPVC SDR 11 fittings as in walls, ceiling, floor, etc. complete all as specified and directed.
20
-
-
... More
S&F CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11 fittings as in walls, ceiling, floor, etc. complete all as specified and directed.
20
-
-
... More
S&F UPVC pipes 50 mm bore (Outer dia) of SCH-40 and plain UPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors complete all as directed.
15
-
-
... More
S&F 20 mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA) comlete all as specified and directed.
4
-
-
... More
S&F 50 mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA) comlete all as specified and directed.
4
-
-
... More
S&F 20mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA) comlete all as specified and directed.
4
-
-
... More
S&F 50 mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA) comlete all as specified and directed.
4
-
-
... More
S&F in repairs vitreous china squatting pan of “Orissa” pattern of size 580 mmx 440mm white with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and as directed.
4
-
-
... More
S&F in repairs vitreous China wash down water closet pan ( padestal pattern) incl PVC seat cover , (excluding fixing bolts, flushing cistern and flush pipe) , including connection to drain ( or outgoing pipe) and to flushing pipe etc. comlete all as specified and directed.
2
-
-
... More
Supply PVC valveless, symphonic action type low level flushing cistern white with inlet ball valve, float and handle including brackets, 10 ltr capacity complete with flush pipe(Long bend) 32mm dia of make as approved by GE complete all as specified & directed.
6
-
-
... More
S&F in repairs vitreous china wash hand basin, white, flat back, size 550mm x 400mm, exc chain and plug and porcelain stopper but including cutting for and pinning in ends of and including brackets, waste pipe & PTMT waste coupling of 32mm dia complete all as specified and directed.
6
-
-
... More
S&F half stall Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe comlete all as specified and directed. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
4
-
-
... More
S&F in repairs Brass chromium plated bottle traps of 32 mm bore for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap fixed complete all as specified and directed.
6
-
-
... More
S&F 15mm bore in repairs CP angular valve with crutch handle, screwed for iron pipe or for brass ferrule and fixed of following size comlete all as specified and directed.
6
-
-
... More
S & F 15 mm Dia in repairs CP Bib taps, with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed .
6
-
-
... More
S & F in repairs 15 mm Dia CP stop cock , with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed .
5
-
-
... More
S&F 15 mm bore pillar taps, Chromium Plated, with capstan heads, chromium plated, screwed down for pipe, high pressure , with or without l'ettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe complete all as specified and directed.
5
-
-
... More
S&F in repair 15 mm bore Brass CP Health faucet screwed down for iron pipe and fixed all as specified and directed.
2
-
-
... More
S&F PVC connection 15 mm size pipe with PTMT nut of Length 600mm comlete all as specified and directed.
4
-
-
... More
S & F in repair 110/125 mm floor trap fixed in floor with grating incl jointing with solvent (1:2:4) cement concrete,complete all as spd and directed
6
-
-
... More
S&F PTMT in repair grating of 100mm dia, fixed with cement mortar (1:3) complete all as specified and directed.
6
-
-
... More
Dismantling of old unserviceable water tank, removing from site, Supply and fixing of rotational moulded polythene water storage tank 1000 litre capacity ISI marked (cylindrical, vertical, double layered with closed top) hoisted and fixed in position including PVC float valve 20mm bore weight not less than 210gms. Complete all as specified and directed.
4
-
-
... More
Dismantling of old unserviceable water tank, removing from site, Supply and fixing 2000 Litre capacity rotational moulded polyethylene water storage tanks (multilayer.cylindrical vertical with closed top) with and including 50 mm dia PVC float valve hoisted and fixed in position complete in all respect as specified and directed.
4
-
-
... More
Chipping of unsound /weak concrete materials including cover plaster from RCC structural member i.e. beams, columns,Slab,chajja,fins etc. 50 mm average thickness including tapering all edges, making square shoulders of cavities air and cleaning of exposed concrete surface of lightly picking materials by manual method including foreign materials , loose concrete/aggregate etc and disposal of all debris out side of MOD land and complete all as specified and directed.
600
-
-
... More
Removing of concrete all around reinforcement bar upto 12 mm dia and over from behind the reinforcing bars average 25mm (but not less than 15mm air gap)by manual methods (using wire brushing ,chiselling etc) and applying chloride free rust removing chemical on rusting steel reinforcement bar and removing all rust from steel reinforcement bar by emery paper and cleaning the area throughly by water and allow it to dry and totally rust free of reinforcement bar all as complete as per manufacturer's instruction as specified and as directed.
800
-
-
... More
Material , labour and prepared existing reinforcement surface by brush and application two component epoxy zincrich primer on existing reinforcement surface of minimum specific gravity 1.75, adhesive bond strength with steel is 1.50N/mm2 and maximum coverage area 5.00 Sqm per litre complete all as specified and directed.(INCL necessary scaffolding)
800
-
-
... More
Material and labour for introducing new reinforcement bars upto 12 mm dia and over for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling,fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified and directed inluding necessary scaffolding complete all as specified and directed.
100
-
-
... More
Material , labour and placing in position free flow shrinkage cementitious micro concrete of compressive strength, flexural strength shall not be less than 50 MPa at 28 days , 5MPa at 28 days respectively for strengthening of beams, columns & other structural elements of average thickness 50mm and including surface preparation & suitable type formwork etc. as per manufacturers instruction complete all as specified and as directed.
600
-
-
... More
Supply, materials and application of two component structural grade polymer modified reinstatement mortar of compressive strength, flexural strength shall not be less than 45 MPa at 28 days , 7MPa at 28 days respectively (Maximum coverage area 1.3 sqm per 25 kg pack @ 10 mm thickness) over a coat of epoxy Bonding agent on existing surface for strengthening of beams, columns & other structural elements of average thickness 25mm and morter shall be applied in layers n.exc 6mm thick in layers and including surface preparation as per manufacturers instruction complete all as specified and as directed.
Note:- This item shall be executed where shuttering is not possible or small patch repairs of structural elements .
125
-
-
... More
Material , labour for applying of high efficiency polymeric resin base film forming curing agent/compound over concrete surface and maximum coverage area 5.00 Sqm per litre as per manufacturers instruction complete all as specified and as directed. (INCL necessary scaffolding)
600
-
-
... More
Dismantling of existing Expansion joint system and M & L applying TPO/FPO based joints sealing membrane, Sikadur Combiflex SG (150x2mm) with epoxy adhesive, Sikadur 31 C ( the joint shall be packed withing polystyrene board before application of Combiflex ). Then providing Sika pllystrene sealant into the gap after proper surface prepration after filling the gap with polyurethene backer rod, followed by precast RCC slab (1:2:4 ) 50 mm thick placed over the joint with minimum 150 mm projection on either side with proper drip course of size (length) n.exc. 1.2 mtr each and sealing the joints of precast RCC slab with exterior grade silicone sealant of size i.e. 10 mmx 10 mm balance with polystrene board complete all as specified and as directed.
25
-
-
... More
M&L for hoisting, assembly and fixing of double layer steel scaffolding to external perimeter of building duly cross braced and properly aligned for the functional aspect and safety of the building including dismantling, shifting & removal from site complete all as specified and directed.
Note: - Elevational area of the scaffolding facing the building shall be measured for payment.
350
-
-
... More
Supply and Application Cementitious Grouting Admixture with the Cement slurry at a dosage 225 ml per bag of cement and injecting with high pressure by a Pressure grouting Pump through non return PVC nozzles Prefix with rapid setting cementitious Plugging Mortar to fill all possible pores and gaps left within the old concrete mass. When the flow of grout stops or shows refusal or grout flows out from the adjacent nozzle, pumping to be stopped and the nozzle to be tied up and allowed to set for 24 hours. The PVC nozzles to be sealed off with quick-setting cementitious plugging mortar. Grouting operation to be carried out through next nozzle till the entire area is covered. The grouting holes to be finished by removing the protruded portion of nozzles and finishing flush with the surface complete all as specified and directed.
50
-
-
... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
3.5
-
-
... More
S & F collapsible steel gates, top hung consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with hold fasts and brackets, complete all as specified and directed.
10
-
-
... More
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings or similar pattern roof coverings .
200
-
-
... More
S&F for Pre painted galvalume aluminium zinc coating GI based corugated steel sheet 0.50mm thick Hi-Rib colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.
180
-
-
... More
S&F for Pre painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick Hi-Rib colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/valley gutter fixed with self tapping screws as specified.
20
-
-
... More
Taking down rolling shutters including fittings complete all as specified and directed.
4
-
-
... More
S & F steel rolling shutters of 1.25 mm thickness laths without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated complete push & pull & gear operated type with bevel gear box and crank handle.
20
-
-
... More
S & F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-16 complete all as specified and directed.
250
-
-
... More
M&L two Coats of Synthetic Enamel Paint over one coat of primer to steel and iron surfaces of any description, not otherwise described including preparation of new or previously untreated surface complete all as specified and directed.
50
-
-
... More
M&L for two coats of synthetic enamel paint over a coat of pink primer area exc.10cm width or girth over new wooden surfaces including preparation of surface complete in all respect as specified and directed.
10
-
-
... More
M&L for one coats of synthetic enamel paint, area exc.10cm width or girth over Old painted wooden surfaces including preparation of surface complete in all respect as specified and directed.
20
-
-
... More
M&L for applying Finishing walls in new surfaces with Acrylic Smooth exterior paint of required shade : New work (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete in all respect as specified and directed.
120
-
-
... More
M&L for applying Finishing walls in old surfaces with Acrylic Smooth exterior paint of required shade (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) with complete removal of existing paint complete in all respect as specified and directed.
250
-
-
... More
M&L preparation of new plastered surface and applying three coats of white wash on ceiling all complete all as specified and directed.
20
-
-
... More
M&L for preparation of old plastered ceiling surface by complete removal of existing treatment and applying two coat of white wash complete all as specified and directed.
25
-
-
... More
M&L for preparation of new plastered surfaces of wall and applying two coat of oil emulsion distemper over a coat of primer complete all as specified and directed.
80
-
-
... More
M&L preparation of old decorated surface by complete removal of existing treatment and applying two coat of oil emulsion distemper over a coat of primer complete all as specified and directed.
170
-
-
... More
M & L for Cement concrete in saucer drains Type B1 (1:2:4) (20 mm graded stone aggregate) slope maintained as per site requirement complete in all respect as specified.
2
-
-
... More
M&L for 75mm thick PCC (1:3:6), type C2, using 40mm graded stone aggte as in plinth protection / paving, surfae finished even & smooth with using extra cement as complete as specified and directed.
50
-
-
... More
Demolition of cement concrete of any description and in any position not other wise specifiy provided for complete in all respect as specified and directed.
41.5
-
-
... More
M&L 100mm thick cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed.
415
-
-
... More
M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick,set, jointed and pointed in neat cement slurry in floors with grey cement in equal proportion & no pigment over 15mm thick screed bed with CM (1:6) complete all as specified and as directed.
10
-
-
... More
M&L sand filling under floor or in floor or paving, laid in including watering and consolidation true surface for laying paver block.
0.65
-
-
... More
M&L 60 mm thick machine pressed precast interlocking paver block any shape and size with grey cement and no pigment confirming to IS 15658-2006 complete all as spd and directed.
10
-
-
... More
M&L for Moorum/red balri filling in floors are paning laid in layer n exc 15cm thick, spread levelled and rammed including watering complete all as specified.
35
-
-
... More
Material and labor for LED signage visible from both side of size not less than 3 x 0.9 m made out of sandwiched transparent acrylic sheet (minimum 6 mm thick) and necessary computerized laser cutting for letters/ signs illuminated with LED light 6 watt, 12 volt of approved color along with necessary driver and twin core PVC insulated and sheathed multistrand copper conductor 1.5 sq mm up to 1.0 mtr for connection including fixing arrangement to wall or ceiling including taking down of old signage all as specified and as directed.
[Note: - The letters or symbols or signs will be engraved as per direction and a sample printed on plain paper as per actual size should be got approved from and all as directedbefore manufacture.
3.5
-
-
... More
Removal of plants /vegetation on roof tops including removal of sludge deposited over roof n exc 50mm thick including cleaning the roof top with wire brush and washing with fresh water and removing out of MoD land of bldgs 10 to 12 storey of height complete all as specified and as directed.
30
-
-
... More
Grubbing up tree trunk including cutting of trunk portion protruding exc. 30 cm and n exc. 100 cm over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site complete all as specified and directed.
20
-
-
... More
Cleaning of deposited earth , silt debris from covered drain after shifting of drain cover and placed the drain cover to its original positon after cleaning of drain complete excavated earth shall be removed outside MD land exc 1.5 KM but not exc 5 KM distance complete all as specified and as directed.
30
-
-
... More
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit and refixing the serviceable item on origional position (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.all as specified and directed.
130
-
-
... More
Material and labour in repair for point wiring for one light/fan/call bell point with 1.5 sqmm PVC insulated FRLSH unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FRLSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through suitable size of non metallic rigid PVC heavy duty of size 25 mm dia having wall thickness not less than 1.5mm with all accessories and sunk cast pressed steel terminal box made out of MS sheet 1.25mm thick for mounting of fittings like switch, socket and fan regulator with 3mm thick bakalite sheet cover or for fixing of switch/sockets/regulators etc as per site requirement after and making good the distrubed surfaces as per the existing complete all as specified and as directed.
75
-
-
... More
All as per item No 107 here-in-before but for 3 pin 6 Amps socket outlet on the same board with 1.5 sqmm cable complete as specified and directed.
15
-
-
... More
All as per item No 107 here-in-before but for 3 pin 6 Amps switch socket combination on the independent board with 1.5 sqmm cable complete as specified and directed.
20
-
-
... More
All as per item No 107 here-in-before but for switch socket combination 2 in 1,3 pin 5/15 Amp on independent board with 2.5 Sqmm PVC unsheathed copper cable and 2.5 sqmm copper conductor cable as earth continuity conductor complete as directed.
20
-
-
... More
S & F in repair socket outlet 2 in 1, 5 pin 5 Amp,230 Volts flush type.
15
-
-
... More
M & L in repair for switch socket combination 2 in 1, 5 pin 5 Amps, 240 V Flush type, all as specified.
20
-
-
... More
Supply and fix in repair switch socket combination 2 in 1,5/15 Amps, 230 Volts, flush type universal complete all as specified and as directed.
20
-
-
... More
Supply and fixingin repair switch piono, flush type 5 Amps 230 Volt single pole, one way complete all as specified and as directed.
45
-
-
... More
Supply and fixing in repair ceiling rose surface bakelite three terminal 65 x 50mm, PVC/Polycarbonate,isolated body complete all as specified and as directed.
35
-
-
... More
S&F in repair fan regulator electronic, flush type humming with (step type) polycarbonate body suitable to control speed of fan from 0 to 100% and connecting electrically all as specified and directed.
15
-
-
... More
Supply and fixing in repair sub-main wiring conceaed surface type as directed from main DB's to sub DB's with PVC (FRLSH) insulated & unsheathed two runs of 6 sq mm single core multi stranded copper conductor cable, 1100 Volt grade alongwith one run of 6 sq mm PVC (FRLS) insulated & unsheathed copper conductor cable, 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through PVC Conduit carefully and taken down old existing aluminium sub main wiring with accessories complete all as directed. Note : Three runs of 6 sqmm and with PVC Conduit shall constitute one unit.
50
-
-
... More
All as per item No 117 here-in-before but with 4.0 sqmm copper conductor cable.
100
-
-
... More
All as per item No 117 here-in-before but with 2.5 sqmm copper conductor cable.
50
-
-
... More
Supply and Fixing in replacement MCB, single pole, 240 Volts, of capacity (6-32 Amps) 'C' series breaking capacity 10 KA.
30
-
-
... More
Supply and fixing in repair MCB SPN, 16 to 32 Amps, 240 Volts , breaking capacity 10KA complete all as directed.
11
-
-
... More
Supply and fixing in repair MCB TPN 63 Amps, 415 Volts , breaking capacity 10KA complete all as directed.
2
-
-
... More
Supply and fixing as in repair MCB DB SPN (double door) 12 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed.
5
-
-
... More
Supply and fixing as in repair MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by.
5
-
-
... More
Supply and fixing as in repair MCB DB TPN (double door) 4 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed.
1
-
-
... More
Supply and fixing in repair of Vertical TPN DBs with , double door with IP-43 protection suitable for TP/FP MCCB upto 250 Amps as incomer and TPN/SPN MCB as outgoing 415 volts 4 way without MCCB & MCBs, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Make :- Cat Part No : 5077-50, Model No DPX³ 160+12 of Legrand or equivalent in Havells/L&T.
Note:- MCCBs/ MCBs will be measured and paid for separetely.
1
-
-
... More
M&L for taking out unserviceable DBs of any type / capacity incl MCBs for fixing of new or old all as directed
12
-
-
... More
Supply and fixing in repair MCCB 4Pole upto 200 Amps, 415 Volts ,Adjustable type breaking capacity 35KA including nut bolts lugs & cable of suitable size complete all as directed.
1
-
-
... More
Supply and fixing in repair building security lighting of LED 35 watts high efficennt lighting solution anodised with heat resistance with accessories provided including necessary electric connection with all accessories required for fixing/mounting with nut bolt washer & clamp support on GI pipe1.5 meters long of suitable diameter complete all as specified and as directed. Make- Cat No:ENDCITYLITPLAT+SL35W LED 757 SASYBOPCWOSPD of Havells or equivalent in Crompton/Syska.
5
-
-
... More
Supply and fixing in repairs main stream battens fitting LED 20 watt with tube 4 feet long fixing on PVC/wooden round block complete with all accessories, prewired and flexible wire twin core from ceiling rose to terminal block complete all as specified and as directed.
20
-
-
... More
Supply and fixing in repairs design from the renaissance era yet with a modern look using new generation technology in 35W LED to enliven outdoor areas in perfect synchronization with functionality and aesthetics. IP66 Family of post top lantern designed to complement the geometry of the area including all accessories and connection complete all as specified and as directed. Make :- Cat Part No VICTORIAPT35WLED 757PSYMTOTG of Havells or equivalent in Crompton/ Bajaj.
3
-
-
... More
Supply and fixing in repairs aesthetically designed decorative hot dipped galvanised mild steel step 3M pole with grey powder finish. Compatible for all post top range. Window - Plasma cut & duly chamfered opening window of 300 x 110 mm for terminal connections & mounting accessories. Window cover is fitted with allen screws to the pole including necessary PCC work complete all as specified and as directed.
Make :- Cat Part No DECO POLE 3M TOP dia 76mm of Havells or equivalent in Crompton/Bajaj.
3
-
-
... More
Taking down exhaust fan/wall mounted of any type, any make, by opening of body carefully checking for repalcement of unserviceable spares, including replacement of spares by new one, re-assembling of all components in original position, cleaning, oiling greasing, testing and fixed in original position.
15
-
-
... More
M&L for Painting of Exhaust fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, two coat after cleaning all dust etc.all as directed.
10
-
-
... More
Materials and labour for earthing as complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 32 x 6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded stone aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed.
10
-
-
... More
Dismantling and taking out old earth plate with connected material from site complete all as specified and directed.
10
-
-
... More
Supply & fixing single galvanised strip of size 32x6 mm galvanised iron in proper positon saddles and fixing screws on porcelain Insulator for roof conductors and down conducrors from top to the building air termination point to the test points of the building as required after and including taking out old unsv and make good the disturbed surface complete all as specified and directed.
70
-
-
... More
Dismantling and taking down old earth continuity conductot from site complete all as specified and directed.
270
-
-
... More
Supply & fixing aluminium strip of size 25 x 3 mm in proper positon saddles and fixing screws on porcelain Insulator for roof conductors and down conducrors from top to the building air termination point to the test points of the building as required after and including taking out old unsv and make good the disturbed surface complete all as specified and directed.
200
-
-
... More
Supply & fixing for Test point box of suitable size including terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw and connected with earthing strip including taking out old unsv and make good the disturbed surface complete all as per directed.
10
-
-
... More
M & L GI tubing light grade 40mm bore with fitting complete fixing to walls and ceilings or laid in floors for passing of cable with suitable size clamps complete all as specified and as directed.
60
-
-
... More
M & L for fabrication of aluminium bulletin board made out of double door shutter of size 884 mm x 593mm using 40mm x 18mm aluminium section, main frame of size 1222mm x 921mm made of aluminium section 40mm x 18mm duly strengthened by another aluminium section of size 20mm x 20mm complete duly fixed with sunmica of size 1220mm x 920mm x 3mm high class PVC gasket complete including two steel handles with magnetic locks at shutter to facilitate smooth opening.
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%