Military Engineer Services Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 Jan 2025
Closing Date27 Jan 2025
Tender Amount₹ 37,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR MAINT OF LT PANELS, SWITCHGEARS, LT CABLES OF DIFFERENT MD ACCNS AND REPAIR MAINT OF APFC PANELS LIGHTING CONDUCTOR, EARTHING, TRAFFIC SIGNAL LIGHTS INCL MISC WORKS AT SUB STN NO 7 TO 10, JSA ENCLAVE, JCO MAP PH-I AND ECIB UNDER GE FW KOLKATA
REPAIR MAINT OF LT PANELS, SWITCHGEARS, LT CABLES OF DIFFERENT MD ACCNS AND REPAIR MAINT OF APFC PANELS LIGHTING CONDUCTOR, EARTHING, TRAFFIC SIGNAL LIGHTS INCL MISC WORKS AT SUB STN NO 7 TO 10, JSA ENCLAVE, JCO MAP PH-I , ECIB UNDER GE FW KOLKATA
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
75 Sqmm to 120 Sqmm, 3.5 core

750

-

-

... More
150 Sqmm to 185 Sqmm, 3.5 core

650

-

-

... More
240 Sqmm to 400 Sqmm, 3.5 core

400

-

-

... More
Excavation in trenches not exc 1.5 metre width and not exceeding 1.5 metre in depth in soft/loose soil and getting complete all as specified and as directed.

500

-

-

... More
Excavation of trench in road/hardstanding etc, not exc 1.50 m wide and not exc 1.50 m deep and getting out complete all as specified and directed.

5

-

-

... More
Returning, filling in including spreading levelling watering and well ramming in layers n.exc 25 thick for soft/loose soil complete all as specified and as directed.

250

-

-

... More
Removal of excavated material to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.

213

-

-

... More
M&L for sand cushioning / sand covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and as directed. Note: For the purpose of payment, punned thickness of sand cushioning only shall be measured.

190

-

-

... More
Supply and laying in trenches sub class 'B' Bricks, Kiln burnt, for cable protection, complete all as specified and as directed.

6000

-

-

... More
Taking out carefully interlocking paver block, of any size or shape and re-laying in the same position after relaying of LT Cable, duly removing all vegetation, algae, grass etc., laid in proper slope and gradient over sand cushioning, complete all as specified and directed. Note: Sand, if required for correction of cushioning level shall be measured and paid separately. Replacement of broken paver blocks shall be separately as "Supply only"

60

-

-

... More
Supply only machine pressed precast concrete interlocking paver block with grey cement and pigment of any shape and size as approved by GE conforming to IS-15658-2006 of 60 mm thickness, M-35 grade with 6 mm top layer of coloured rubberised anti abrasive material complete all as specified and directed.

50

-

-

... More
Relaying of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall / passing through pipe/ pole. (retrieved against item No 1 above) after fault rectification incl necessary aluminium thimbles, jointing and testing complete all as directed by the Engr-in-Charge of the following sizes :- (Note :- Necessary earth work to be measured and paid separately.

-

-

-

... More
10 Sqmm to 16 Sqmm, 4 core

150

-

-

... More
25 Sqmm to 50 Sqmm, 3.5 core

180

-

-

... More
70 Sqmm to 120 Sqmm, 3.5 core

200

-

-

... More
150 Sqmm to 185 Sqmm, 3.5 core

200

-

-

... More
240 Sqmm to 400 Sqmm, 3.5 core

200

-

-

... More
Supply, Laying and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole incl necessary aluminium thimbles, jointing and testing complete of the following sizes and cross sectional area :- (Note :- Necessary earth work to be measured and paid separately.

-

-

-

... More
35 Sqmm, 3.5 Core

300

-

-

... More
50 Sqmm, 3.5 Core

300

-

-

... More
95 Sqmm, 3.5 Core

300

-

-

... More
120 Sqmm, 3.5 Core

200

-

-

... More
150 Sqmm, 3.5 Core

200

-

-

... More
185 Sqmm, 3.5 Core

200

-

-

... More
240 Sqmm, 3.5 Core

200

-

-

... More
S&F heat shrinkable straight through Joints using suitable jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge for the following size of cables :-

-

-

-

... More
25 Sqmm to 50 sqmm 3.5/4 core

4

-

-

... More
70 sqmm to 150 sqmm, 3.5 core

5

-

-

... More
185 sqmm to 240 sqmm, 3.5 core

5

-

-

... More
300 sqmm to 400 sqmm, 3.5 core

2

-

-

... More
S&F cable route indicator (blue in colour) for LT UG cable of 1100 Volts, with embossed letters, min 80 mm dia, made from 5 mm thick cast iron plate 80 mm dia, bolted with 40 x 40 x 6 m angle iron of height 0.60 mtr above GL, embedded in PCC (1:3:6) type C2 (using 40 mm graded aggregate) of size 200 x 200 x 200 mm block, including taking down old unserviceable one, complete all as specified and directed. (NOTE: Cost of PCC is deemed to be included in the quoted rate)

25

-

-

... More
Supply and fix (in replacement) ACB, 800 amps, 4 pole, with microprocessor based release, Ics=50% of Icu, manual drawout type, with overload, short circuit & ground fault protections with inbuilt display for current metering with high accuracy of class 1, internal battery, communication port, inbuilt USB port for software diagnosis, all accessories incl taking down existing ACB complete all as specified and directed. (Make: L&T /LEGRAND/ SCHNEIDER/ABB / SIEMENS) or equivalent make specified in tender.

2

-

-

... More
S&F in repair MCCB 630 Amps, 4 pole, 50 kA, 415 Volts, with microprocessor based release with electronic Sg (LSg) protection unit, Ics=100% of Icu with overload, short circuit & ground fault protections with in built display for current metering with high accuracy of class 1, internal battery, communication port, inbuilt USB port for software diagnosis, with all accessories, complete all as specified and directed. (Make: L&T / LEGRAND/HAGER /SCHNEIDER/ ABB/ SIEMENS)or equivalent make specified in tender.

2

-

-

... More
S&F in repair MCCB 400 Amps, 4 pole, 50 kA, 415 Volts, with microprocessor based release with electronic Sg (LSg) protection unit, Ics=100% of Icu with overload, short circuit & ground fault protections with in built display for current metering with high accuracy of class 1, internal battery, communication port, inbuilt USB port for software diagnosis, with all accessories, complete all as specified and directed. (Make: L&T /LEGRAND/ HAGER/ SCHNEIDER/ABB / SIEMENS) or equivalent make specified in tender.

3

-

-

... More
S&F in repair MCCB 320 Amps, 4 pole, 36 kA, 415 Volts, with adjustable type, Ics=100% of Icu, with all accessories & copper spreader complete all as specified and directed. (Make: L&T / LEGRAND / HAGER/ SCHNEIDER/ ABB / C&S / SIEMENS) or equivalent make specified in tender.

2

-

-

... More
S&F in repair MCCB 250 Amps, 4 pole, 25 kA, 415 Volts, with adjustable type, Ics=100% of Icu, with all accessories & copper spreader complete all as specified and directed. (Make: L&T / LEGRAND / HAGER/ SCHNEIDER/ ABB / C&S / SIEMENS) or equivalent make specified in tender.

2

-

-

... More
S&F in repair MCCB 200 Amps, 4 pole, 25 kA, 415 Volts, with adjustable type, Ics=100% of Icu, with all accessories & copper spreader complete all as specified and directed. (Make: L&T / LEGRAND / HAGER/ SCHNEIDER/ ABB / C&S / SIEMENS) or equivalent make specified in tender.

2

-

-

... More
S&F in repair MCCB 160 Amps, 4 pole, 25 kA, 415 Volts, with adjustable type, Ics=100% of Icu, with all accessories & copper spreader complete all as specified and directed. (Make: L&T / LEGRAND / HAGER/ SCHNEIDER/ ABB / C&S / SIEMENS) or equivalent make specified in tender.

2

-

-

... More
S&F in repair MCCB 100 Amps, 4 pole, 25 kA, 415 Volts, with adjustable type, Ics=100% of Icu, with all accessories & copper spreader complete all as specified and directed. (Make: L&T / LEGRAND / HAGER/ SCHNEIDER/ ABB / C&S / SIEMENS) or equivalent make specified in tender.

8

-

-

... More
S&F in repair MCCB 63 Amps, 4 pole, 25 kA, 415 Volts, with adjustable type, Ics=100% of Icu, with all accessories & copper spreader complete all as specified and directed. (Make: L&T / LEGRAND / HAGER/ SCHNEIDER/ ABB / C&S / SIEMENS) or equivalent make specified in tender.

10

-

-

... More
Dismantling carefully serviceable isolating LT Panel board of sizes 1500mm x 900 mm x 600 mm to 2500 mm x 2000mm x 900 mm, duly unscrewing/ opening front and back cover and cleaning complete bus bar chamber, tightening all the nuts, bolts incoming and outgoing terminals including cleaning the all switchgear/ accessories and replacement of cable gland and replacement of stainless steel hinges of size 100mm for panel board door fixed with welding machine incl applying one coat of synthetic enamel paint externally to panel board after scrubbing/cleaning the surface complete testing the Panel board till satisfaction of Engr-in-Charge, complete all as specified and directed.

4

-

-

... More
Dismantling carefully serviceable isolating LT Panel board complete of sizes 500mm x 500 mm x 500 mm to 1500 mm x 900 mm x 600 mm duly unscrewing/ opening front and back cover carefully and cleaning complete bus bar chamber, tightening all the nuts, bolts incoming and outgoing terminals, cleaning the all switchgear/ accessories and replacement of cable glands and replacement of stainless steel hinges of size 100mm for panel board door fixed with welding machine incl and applying one coat of synthetic enamel paint externally to panel board after scrubbing/cleaning the surface, complete testing the Panel board till satisfaction of Engr-in-Charge, complete all as specified and directed. Note for item No. 25 (i) Cost of necessary nuts, bolts, washers, screws and colour tape for bus bar, recharging and testing complete shall be deemed to be included in the unit quoted rate. (ii) Quantity of Stainless steel hinges as per site requirement shall be deemed to be included in the quoted rate

1

-

-

... More
Dismantling / Disconnecting electric connection of UG LT XLPE cable, 35 Sqmm to 400 Sqmm, 1100 Volts grade, for finding the earth fault from both sides of cable and locating the fault in LT cable with fault locating machine in the entire length, complete testing after reconnecting and commissioning of cable, complete all as specified and directed. (NOTE: The testing shall be conducted only after obtaining the proper shutdown from the Main Power House, in the prengence of GE / Engineer-in-Charge)

4

-

-

... More
Taking out old unserviceable LT panel board of any size and type and Supply, install, commissioning and testing of Indoor type LT panel board, cubical type, Flat top roof, dust and vermin proof, made out of 2.00 mm thick CRCA sheet of size 1800mm x 1800mm x 600mm, CPRI approved with front & back operable door (with locking arrangement) and making compartment for each MCCB separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers Copper bus bar 1000 Amps of adequate size for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper spreader and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and 01 Nos Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS Channel of size 50 x 50 x 6mm with 450 mm legs fixed with PCC complete all as directed by the Engr-in-Charge including supply and fixing of the following accessories:-

1

-

-

... More
ATS 630 Amp, 4 Pole + AST Controller - 01 Nos (Incoming).

-

-

-

... More
MCCB with thermal-magnetic releases of capacity 630A, 4P, 50 KA - 02 Nos (Incoming).

-

-

-

... More
Surge Protection Device, 3 Phase, 4 module, 1+ 2 type, maximum discharge current 100 kA - 02 Nos

-

-

-

... More
MCCB with thermal-magnetic releases of capacity 200A, 4P, 40 KA - 03 Nos (Outgoing).

-

-

-

... More
MCCB with thermal-magnetic releases of capacity 160A, 4P, 25 KA - 04 Nos (Outgoing).

-

-

-

... More
MCCB with thermal-magnetic releases of capacity 100A, 4P, 25 KA - 01 Nos (Outgoing).

-

-

-

... More
Digital Ammeter with Selector Switch - 01 No.

-

-

-

... More
Digital Voltmeter with Selector Switch - 01 No.

-

-

-

... More
MCB SP 6 Amps, 10 KA - 3 Nos. Make : L&T

-

-

-

... More
LED type indication lamp R Y B - 01 (set of 03)

-

-

-

... More
Current Transformer Ratio 630/5A - 03 Nos

-

-

-

... More
(i) All incoming and outgoing cables, duly thimbled along with suitable size of brass cable glands, to be connected with accessories. (ii) All MCCB & Changeover to be connected internally with suitable size of copper strip.

-

-

-

... More
Supply and fixing in repair Motorised Changeover switch open execution type, 415V, 3 phase 4 pole 125 Amps with AST Controller with wire harness to be fixed on existing panel board all as directed by Engr-In-Charge Make : L&T Cat Part No. CK90161B000 + CK901920000 or equivalent make specified in tender.

2

-

-

... More
Supply and fixing in repair Motorised Changeover switch open execution type, 415V, 3 phase 4 pole 200 Amps with AST Controller with wire harness to be fixed on existing panel board all as directed by Engr-In-Charge Make : L&T Cat Part No. CK90161B000 + CK901920000 or equivalent make specified in tender.

2

-

-

... More
Supply and fixing in repair Motorised Changeover switch open execution type, 415V, 3 phase 4 pole 400 Amps with AST Controller with wire harness to be fixed on existing panel board all as directed by Engr-In-Charge Make : L&T Cat Part No. CK90161B000 + CK901920000 or equivalent make specified in tender.

1

-

-

... More
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 25 X 4 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.

14

-

-

... More
Supply and fixing GI tubing 50mm bore (light grade) in trenches/floor/fixed along pole for cable incl taking down old unsv pipe complete all as specified and as directed .

24

-

-

... More
Supply and fixing 80 mm bore galvanized iron pipe (light grade) with all fittings, fixed in trenches/floor/fixed along pole for cable incl taking down old unsv pipe complete all as specified and as directed.

18

-

-

... More
Supply and fixing 100 mm bore galvanized iron pipe (light grade) with all fittings, fixed in trenches/floor/fixed along pole for cable incl taking down old unsv pipe complete all as specified and as directed.

18

-

-

... More
M&L for Opening & Disconnecting LT Cable Connections with carefully from Automatic Power Factor Panels of 30 KVAr to 40 KVAr capacity, checking of the panels installed at RRC Sub Stn, ECCIU Sub Stn, Sub Stn No.1, 2 and testing their operation and mechanical system including detection and replacement of the unserviceable parts/ accessories required at site to make the Power Factor Panel completely functional including cleaning/ servicing of complete unit and re-connection of the panel complete all as specified and directed. Note :- Provision of new spare parts as required shall be measured and paid separately.)

7

-

-

... More
M&L in repairs of capacitor Heavy duty square(box) type, 5 KVAr Rating @ 440V, 3Ph, 50Hz including taking out old unserviceable, complete all as specified and as directed. MAKE : EPCOS/ L&T/ SCHNEIDER or equivalent make specified in tender.

10

-

-

... More
M&L in repairs of capacitor Heavy duty square(box) type, 10 KVAr Rating @ 440V, 3Ph, 50Hz including taking out old unserviceable, complete all as specified and as directed. MAKE : EPCOS/ L&T/ SCHNEIDER or equivalent make specified in tender.

2

-

-

... More
M&L in repairs of capacitor Heavy duty square(box) type, 15 KVAr Rating @ 440V, 3Ph, 50Hz including taking out old unserviceable, complete all as specified and as directed. MAKE : EPCOS/ L&T/ SCHNEIDER or equivalent make specified in tender.

2

-

-

... More
M&L in repairs of capacitor Heavy duty square(box) type, 20 KVAr Rating @ 440V, 3Ph, 50Hz including taking out old unserviceable, complete all as specified and as directed. MAKE : EPCOS/ L&T/ SCHNEIDER or equivalent make specified in tender.

2

-

-

... More
M&L in repairs of capacitor Heavy duty square(box) type, 25 KVAr Rating @ 440V, 3Ph, 50Hz including taking out old unserviceable, complete all as specified and as directed. MAKE : EPCOS/ L&T/ SCHNEIDER or equivalent make specified in tender.

2

-

-

... More
M&L in repairs of capacitor Heavy duty square(box) type, 30 KVAr Rating @ 440V, 3Ph, 50Hz including taking out old unserviceable, complete all as specified and as directed. MAKE : EPCOS/ L&T/ SCHNEIDER or equivalent make specified in tender.

1

-

-

... More
M&L in repairs of capacitor Heavy duty square(box) type, 50 KVAr Rating @ 440V, 3Ph, 50Hz including taking out old unserviceable, complete all as specified and as directed. MAKE : EPCOS/ L&T/ SCHNEIDER or equivalent make specified in tender.

1

-

-

... More
M&L in repairs of Contactor 20 Amp, 3 pole, 1NO+1NC, MO C, AC3, 415 Vols, 50 Hz confirm to IS/IEC 60947-4-1 including taking out old unserviceable, complete all as specified and as directed. MAKE : L&T/ SCHNEIDER/ SIEMENS or equivalent make specified in tender.

2

-

-

... More
M&L in repairs of Contactor 25 Amp, 3 pole, 1NO+1NC, MO C, AC3, 415 Vols, 50 Hz confirm to IS/IEC 60947-4-1 including taking out old unserviceable, complete all as specified and as directed. MAKE : L&T/ SCHNEIDER/ SIEMENS or equivalent make specified in tender.

1

-

-

... More
M&L in repairs of Contactor 30 Amp, 3 pole, 1NO+1NC, MO C, AC3, 415 Vols, 50 Hz confirm to IS/IEC 60947-4-1 including taking out old unserviceable, complete all as specified and as directed. MAKE : L&T/ SCHNEIDER/ SIEMENS or equivalent make specified in tender.

1

-

-

... More
M&L in repairs of Contactor 40 Amp, 3 pole, 1NO+1NC, MO C, AC3, 415 Vols, 50 Hz confirm to IS/IEC 60947-4-1 including taking out old unserviceable, complete all as specified and as directed. MAKE : L&T/ SCHNEIDER/ SIEMENS or equivalent make specified in tender.

5

-

-

... More
M&L in repairs of Automatic Power Factor Controller Relay type Voltage 230 Volt 8 Step with 3 Phase / 3 CTs, connecting Single Phase and Three Phase Capacitors, compensation of each Phase, Measures Power Factor with RS-485 including taking out old unserviceable, complete all as specified and as directed. MAKE : SCHNEIDER/ HPL/ L&T/ EPCOS or equivalent make specified in tender.

1

-

-

... More
M&L in repairs of Automatic Power Factor Controller Relay type Voltage 230 Volt 12 Step with 3 Phase / 3 CTs, connecting Single Phase and Three Phase Capacitors, compensation of each Phase, Measures Power Factor with RS-485 including taking out old unserviceable, complete all as specified and as directed. MAKE : SCHNEIDER/ HPL/ L&T/ EPCOS or equivalent make specified in tender.

6

-

-

... More
M&L in repairs of LED indicator lamp (R,Y,B,G) including taking down old unserviceable indicator lamps complete all as specified and directed.

80

-

-

... More
M&L in repairs of Standard Push Button for ON/OFF/TRIP as per existing at site including taking down old Unserviceable Push button complete all as specified and directed.

5

-

-

... More
M&L in repairs of of MCB, TPN, 40 Amp, C - Curve 415 Volts, 50 Hz, including taking down old unserviceable MCB, TPN Complete all as specified and directed.

1

-

-

... More
M&L in repairs of of MCB, TPN, 63 Amp, C - Curve 415 Volts, 50 Hz, including taking down old Unserviceable MCB, TPN Complete all as specified and directed.

1

-

-

... More
M&L in repairs of of MCB, SP, 6-32 Amp, C - Curve, 240 Volts, 50 Hz, including taking down old Unserviceable MCB Complete all as specified and directed.

5

-

-

... More
M&L in repairs of of Selector Switch for operating of Ampere/Voltage including taking down old Unserviceable switch Complete all as specified and directed.

1

-

-

... More
M&L in repairs LED Digital Voltmeter, class 0.5 accuracy, 3 Phase, 415 Volts, 50 Hz, flush mounting 96mm x 96mm including taking down old unserviceable voltmeter complete all as specified and directed.

1

-

-

... More
M&L in repairs LED Digital Ammeter, class 0.5 accuracy, 3 Phase, 415 Volts, 50 Hz, flush mounting 96mm x 96mm including taking down old unserviceable voltmeter complete all as specified and directed.

1

-

-

... More
Isolating the device and checking of LT ACBs 630-800 Amps capacity and testing its operation and tripping devices and mechanical system and setting it right clearing/servicing complete unit and recharging complete in position for Air Circuit Breaker of Make- GE , L&T, Crompton Greaves, Legrand or Schneider or equivalent make specified in tender.

2

-

-

... More
Supply and fixing in repair Motorised Changeover switch open execution type, 415V, 3 phase 4 pole 630 Amps with AST Controller with wire harness to be fixed on existing panel board all as directed by Engr-In-Charge Make : L&T Cat Part No. CK90161B000 + CK901920000 or equivalent make specified in tender.

1

-

-

... More
M&L Repairing Damaged Earth Pit/Chamber in Cement Concrete 1:3:6 (20mm graded stone aggregate) as shown in Electrical Plate No 3 of MES Schedule Part-I including providing Pre-cast RCC Cover in Cement Concrete 1:2:4 (20mm graded stone aggregate) of 350x350x50mm in size, reinforced with and including 10mm dia TMT Bars @ 100mm Centre to Centre in both ways including Funnel and cleaning the surrounding of Earth Pit Cover and pouring Salt Water to improve the resistance and measuring and recording the same in presence of Engineer-in-Charge, complete all as specified and as directed.

20

-

-

... More
M&L Pre-cast RCC Cover in Cement Concrete 1:2:4 (20mm graded stone aggregate) of size 350x350x50mm, reinforced with and including 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, complete all as specified and as directed.

10

-

-

... More
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) provided Around Earthing Pit having Top size 200x200mm and bottom size 300x300mm having 150mm in height, size of PCC Platform 900x900x100mm with fair finished Concrete Surfaces including necessary Formwork and Earth Work as required/ordered at Site including dismantling PCC, complete all as specified and as directed.

10

-

-

... More
Taking out loose/displaced Serviceable Aluminium Strip/ Copper Strip/ GI Strip of any size and any description with Accessories and refixing the same with necessary Fixing Arrangement like Screws, Saddles, Nuts and Bolts, complete all as specified and as directed. NOTE : Cost of Screws, Saddles, Nuts and Bolts, etc. will deemed to be included in the Quoted Unit Rate.

100

-

-

... More
Supply and fixing GI tubing 50mm bore (Medium grade) in trenches/floor/fixed along pole for cable/earth strip protection with proper size of clamp, nuts and bolts or for fixing lightening conductors etc all as specified and as directed.

12

-

-

... More
Material and labour for PCC (1:2:4) type B-2 using 20 mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement, as directed by the Engineer-in-Charge.

2

-

-

... More
Material & Labour for Precast cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate with cement mortar 1:4 as in base of Galvanised Iron strip complete all as specified and directed.

2

-

-

... More
Supply and fixing of porcelain insulator of size 50mm with fixing arrangements including taking down old unserviceable complete all as specified and directed.

250

-

-

... More
M&L in repairs for aluminium Strip of size 25 x 3.00 mm fixed to wall or on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc including taking down old unserviceable strip complete all as specified and as directed.

250

-

-

... More
M&L in repairs for Copper strip 20mm x 3.00mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as directed by Engineer-in-Charge.

100

-

-

... More
M&L in repairs for Galvanized Iron Strip of size 25 x 4.00 mm fixed to wall or on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. including taking down old unserviceable strip complete all as specified and as directed.

100

-

-

... More
M&L in repairs of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire including taking down unserviceable Strip, complete all as specified and as directed.

100

-

-

... More
Supply and fixing Air termination single pointed, aluminium rod 12mm dia and 300mm long fixed on Galvanised iron pipes with copper/aluminium/GI strip for earth conductivity to ground complete all as directed.

20

-

-

... More
Supply and fixing Air termination single pointed, copper rod 12mm dia and 300mm long fixed on Galvanised iron pipes with copper/aluminium/GI strip for earth conductivity to ground complete all as directed.

10

-

-

... More
Supply and fixing test point terminal block made of gun metal or phosphorous bronze size 75mm x 75mm x 25mm, drilled and screwed including 3 Nos, 8mm dia and 25mm long hex head screw complete all as directed.

20

-

-

... More
S&F in repairs Junction box made out of 3 mm thick mild steel sheet including applying two coats of synthetic enamel paint over a coat of zinc chrome primer duly spray painted of size not less than 20 cm x 20 cm x 15 cm with locking arrangements with provision of earthing strip entry and exit , fixed at wall with GI bolts, nuts and washers (of suitable size), incl taking down existing junction box complete all as specified and as directed.

21

-

-

... More
S&F Mild Steel Sheet of size approximate 300x200x1.6mm thick Sheet Egg type, Half round type, Rectangular type and Triangular type with welded 1ʺ (Inch) dia 2ʹ (Feet) long Mild Steel Pipe with duly different Syndetic Enamelled Paint cutting of Equipment Earthing/ Lighting Arrester Earthing/ Signal Earthing, etc. complete as specified duly painted as specified and marking of Earth Plate Number/ Description of Earthing/Type of Earthing on Plate with White Paint including Earth Plate No. and Earthing Resistance with Earthing Check Date and Earthing Check Due Date including taking down unserviceable one, complete all as specified and as directed.

20

-

-

... More
M&L in replacement Earthing complete with Galvanised iron earth plate electrode 600mm x 600mm x 6mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connected with GI wire 4.00 dia connected with nuts, bots, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 25mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 Mtr etc all as shown on electrical plate No.3 of MES Schedule Part-I complete including taking down and testing on completion complete all as specified and as directed by the Engineer-in-Charge.

8

-

-

... More
M&L in replacement Earthing complete with Galvanised iron earth plate electrode 600mm x 600mm x 6mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connected with galvanised earthing strip of size 32mm x 6mm by means of nuts, bots, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 Mtr etc all as shown on electrical plate No.3 of MES Schedule Part-I complete including taking down and testing on completion complete all as specified and as directed by the Engineer-in-Charge.

21

-

-

... More
S&F and testing on commissioning of Advance conductive compound based chemical compound technology with upgraded high tensile low carbon steel rod as per UL 467 and as per BS 7430 with copper Coating 250 microns. Earthing system confirming to IS:3034. The ROD should 17.2 mm & 3 Meter length with rod to tape clamp, CR 125 (type A) additional protection of the terminal. Chemical compound should be The highly Conductive Compound as per BSEN 50164-7with 25kg each bag & resistivity should be 0.05 ohm meter. The job includes digging the pit and refilling the same by forsake Back Fill Compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material/metal having mixed with 3:1 cement , a conductive concrete is formed. The earth pit should provided with a light weight inspection pit cover PT -205 for protection and safe guard of terminals. In areas where soil condition is bad Good earth is to be arranged to fill the excavated pits by mixing forsake a convenient and permanent solution by adding with 3:1 ratio chemical compound with the earth electrode is the main component of the earthing system which is in direct contact with the ground and thus provides a mean of releasing or collecting earth leakage currents. The material should have good electrical conductivity and anti corrosion property in wide range of soil conditions. Make : ABB Forsake as per RB 336. Each earth pit should contain:- 1.) 1 no. copper bonded high tensile low carbon steel, 17. 2 mm dia , 3 meter length. 2.) Rod to tape clamp (type A). 3.) 25kg chemical compound as per BSEN 50164-7 4.) Light weight inspection pit cover with 5000kg weight load capacity Complete all as specified and directed by Engr-in-charge.

4

-

-

... More
M&L in repairs Surge Protection Device, 3 Phase, 4 module, protection against direct and indirect lightning surges type, 1+ 2 type, maximum discharge current 50 KA, fixed at LT panel including complete wiring with adequate size of PVC copper cable complete all as specified and directed. Make : L&T Cat Part No. AUSP123PN50 or equivalent make specified in tender

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.