Military Engineer Services Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date11 Feb 2025
Closing Date6 Mar 2025
Tender Amount₹ 34,43,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)

24

-

-

... More
S&F 1.25mm thick Mild steel sheet / PVC eaves gutters, 150mm dia, galvanised class 3, half round with rounded edges complete all as specified and directed.

24

-

-

... More
S&F 150mm dia Mild steel sheet of 1.25mm thk/ PVC drop ends (for spigot or socket ends) or nozzles complete all as specified and directed.

4

-

-

... More
S&F 150mm dia Mild steel sheet of 1.25mm thk/ PVC stop ends (for spigot or socket ends) or nozzles complete all as specified and directed.

2

-

-

... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.

5.35

-

-

... More
Fixing only of structural mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framingetc (beam, tee, angle, channel or flat section) complete all as specified and directed.

350

-

-

... More
S&F mild steel work as in band, strap, supports or stay for rainwater, ventilating pipes incl bolts if reqd, hoocks and similar small articles conforming to Fe 290 Gde -E-165 complete all as specified.

35

-

-

... More
S&F roof trusses, framed trussed, purlins, crane gantries, rails and fastening and heavy brackets framing (Beam, tee, angle channel or flat section) incl distance pieces, cleats, nut and bolts conforming to FE-410w (grade 250-E quality A) complete all as specified.

150

-

-

... More
S&F mild steel rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates confirming to Fe 410-W (Gde 250 quality A) complete all as specified and directed.

58

-

-

... More
M&L for 1.25mm thick MS Plates (plain or chequered) channels, in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts;square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 -W (Gde- E- 250) quality- A complete all as specified and directed.

5

-

-

... More
Demolition of reed, lathing, single or Double and plaster or chicken wire lathing on walls all as specified and directed.

152

-

-

... More
Demolition of precast concrete block walling and precast concrete articles etc, built in cement mortar complete all as specified and directed.

5.8

-

-

... More
M & L precast cement concrete type C-1 , (1:3:6) (using 20mm graded stone aggt) block masonry with solid blocks exc 10cm in width and setting in CM (1:6) complete all as specified.

52.5

-

-

... More
Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.

1.8

-

-

... More
M&L for reinfored cement concrete (nominal mix) in 1:2:4 type B1 (using 20mm graded aggregate) as Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.

1.8

-

-

... More
M&L for RCC (1:2:4) 20mm graded aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed.

1.2

-

-

... More
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc., complete all as specified and directed.

25

-

-

... More
M & L mild steel TMT Bars10mm dia and over cut to length bend to shape required including cranking bending spirally for column, hooking ends & binding with and including mild steel mild steel wire (ann ealed not less that 0.90 mm dia or securing with chip)

289

-

-

... More
M & L mild steel TMT Bars 6mm to 8mm mm dia and over cut to length bend to shape required including cranking bending spirally for column, hooking ends & binding with and including mild steel mild steel wire (ann ealed not less that 0.90 mm dia or securing with chip)

120

-

-

... More
All as per item no.22 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders all as specified and directed.

115

-

-

... More
Taking down cement plaster on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.

100

-

-

... More
M&L for 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) complete all as specified and directed.

180

-

-

... More
M&L 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:4) on external wall finished even and fair mixed with integral water proofing compound @ 3% by weight of cement or in the manner specified by the manufacturer and in the proportions indicated all as specified and as directed. Note:-WPC will be measured and paid separately as supply only.

190

-

-

... More
M/L for 10mm thick rendering CM(1:6) on other than fair faces of brick or concrete surfaces of internal walls finished even and smooth without using extra cement all as specified and as directed.

112

-

-

... More
M & L 10mm thick rendering on fair faces of brick work concrete surface in CM (1:4) on external wall even and fair mixed with integral water proofing compound @ 3% by weight of cement or in the manner specified by the manufacturer and in the proportions indicated all as specified and as directed.

122

-

-

... More
Supply only integral water proofing compond all as specified and as directed.

78

-

-

... More
M&L for three coats of white wash on newly prepared internal and external wall surfaces complete all as specified and directed.

234

-

-

... More
M & L for Preparing newly plastered surfaces of wall and applying two coat of oil bound distemper over chalk whitining primer over 3mm thick layer of putty all as specified and as directed.

180

-

-

... More
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.

190

-

-

... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.

182

-

-

... More
M&L Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and directed.

170

-

-

... More
M&L Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertical suface like, dado and skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 10 mm thick screed bed in cement mortar (1:4) complete all as specified and directed.

12

-

-

... More
M&L for demolition of stone slabs and tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc.

1.5

-

-

... More
M&L for 75 mm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.

15

-

-

... More
M & L chequered cement concrete tiles 300 x 300 x 25 mm thick set, jointed and pointed in neat cement slurry in floors with grey cement and no pigments over and including 15 mm thick screed bed in CM (1:6) all as specified and as directed.

15

-

-

... More
Demolition of cement concrete (un-reinforced) in ground floor and paving n.exc 15 cm thickness below or above ground level all as specified and as directed.

15.45

-

-

... More
M&L for 40mm thick PCC (1:2:4) type B1 using 20mm graded stone agg as in flooring finished even and smooth using extra cement complete all as specified and directed.

78

-

-

... More
M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.

2.5

-

-

... More
M&L 75 mm thick PCC type C-2, (1:3:6) (40mm graded stone aggt) as in path, plinth protection etc., complete all as specified and as directed.

55

-

-

... More
M&L for 75 mm thick cement concrete (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection laid to slope of 1 in 12 and finishing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges and providing 6 mm thick joints through the thickness of plinth protection duly filled with mastic filling of one part of hot bitumen 85/25 grade and three parts of fine sand (all by weight) complete all as specified and directed.

35

-

-

... More
M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in surface channels, drains including all necessary form work complete all as specified and directed.

3

-

-

... More
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.

65

-

-

... More
Dismantling timber scantlings 40 Sqcm and over in section, in any position (framed work) all as specified and directed.

0.15

-

-

... More
M&L well seasoned second class hard wood timber scantling in timber framed work; fixed in clean sawn complete all as specified.

0.15

-

-

... More
Dismantling of wall & celling boards (fiber pulp insulation etc) or insulation boards /slabs /blankets any thickness, including cover fillets.

120

-

-

... More
S&F 605 X605 mm GI frame work for for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to sorrounding wall using nylon sleeves and screws at 450 mm centre to centre /intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from suffit at approx 900 mm centre to centre with GI cleats and steel expansion fastner with and including ceiling section (not exc 1.2 m length)of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10 .5 mm fixed to the intermediate channel with connecting clieats across the intermediate channel at 457 mm centre to centre.

120

-

-

... More
S&F hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasterners 12.5mm dia 40mm long complete all as specified and as directed.

120

-

-

... More
M&L 4mm thick AC design (600x600mm) building boards, fixed or laid /inserted to GI snap grid framework with screw in ceilings.

120

-

-

... More
M&L three coats of white wash on ceiling on AC boards complete all as specified and directed.

120

-

-

... More
Taking down chowkhats or frame n.exc 1.50 and each with shutter (without taking off shutters from the frame) complete all as specified and directed.

20

-

-

... More
Taking down chowkhats or frame exc 1.50 and not exc 4 sqm each with shutter (without taking off shutters from the frame) complete all as specified and directed.

5

-

-

... More
S&F Steel windows with side hung shutters incl projecting type hinges with steel handle, and steel peg stay complete with glazing bars complete all as specified and directed.

17.28

-

-

... More
S&F Steel windows with side hung shutters incl projecting type hinges with steel handle, and steel peg stay complete without glazing bars complete all as specified and directed.

10.8

-

-

... More
S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete complete all as specified and directed.

1.08

-

-

... More
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.

111

-

-

... More
S&F 3mm thick sheet glass, oridinary quality and glazing with oil putty in square n etc 0.5 sqm in each pane complete all as specified and directed.

15.12

-

-

... More
S&F Pressed steel frames of size 165x60 mm for door with one or more rebates including necessary fixing lugs, butt hinges, lock strike plate etc., complete all as specified and directed.

16

-

-

... More
S & F 30mm thick flush door shutters , solid core construction with black board core and plywood face panels,commercial type on both face complete all as specified hard & fitted to chowkats complete all as specified and directed.

6.5

-

-

... More
S & F 30 mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass gauge etc with cut and mitred beads for securing glass etc size of member of shutter as specified in SSR Pt-1 section 8 and clause 8.24 (a complete all as specified and directed.)

6.5

-

-

... More
S & F Galvanised wire cloth, 0.63 mm nominal dia of wire and average width of aperature 1.4mm and fixed with tinted tacks or galvanised wire staples as in fly proof window and door , complete all as specified and directed.

5

-

-

... More
S&F 140mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.

6

-

-

... More
S&F 200mm size aluminium anodised barrel tower bolts of extruded sections complete all as specified and directed.

12

-

-

... More
S & F 150mm size aluminium handle cast type anodised.

12

-

-

... More
S&F 125 mm size butt hinges, ectruded aluminium alloy with galvanised mild steel hinhe pin, anodised and fixed, type C-22 complete all as specified and directed.

18

-

-

... More
Supply only 125 mm size MS Pressed handle, oval type, stove enamelled black and fixed complete all as specified and directed.

4

-

-

... More
Supply only 125 mm size butt hinges, medium weight , cold rolled, mild steel and fixed complete all as specified and directed.

6

-

-

... More
S & F 300 mm long aluminium alloy, anodised sliding door bolt with hasp and staple (bolt type ) and fixing clip of sheet cost or extruded section or cost aluminium alloy & fixed complete all as specified and directed.

3

-

-

... More
Supply only 300mm long MS sliding door bolts, bolt type, stove enamelled black, with bright bolts not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.

2

-

-

... More
S&F in repairs 20 mm dia curtain rails, mild steel, chromium plated with incl fixing brackets, stops, rollers etc. complete all as specified and directed.

20

-

-

... More
S&F in repairs brass/ S/steel hat and coat hooks, solid body, 250 mm to 300 mm long complete all as specified and directed.

10

-

-

... More
M&L prepration of old painted wooden surfaces of any description, not otherwise described, over 10cm width & applying one coat of synthetic enamel paints all as specified and directed.

10

-

-

... More
M&L prepring surfaces of wood and wood based materials, new or old of any description, not otherwise described and treated with one coat of creosote oil complete all as specified and directed.

25

-

-

... More
M&L prepration of old painted steel surfaces of any description, not otherwise described, over 10cm width & applying one coat of synthetic enamel paints all as specified and directed.

105

-

-

... More
M&L for Preparation of new painted steel and iron surfaces of any description and in any position over 10 cm width or girth as in roof not other wise specially described and applying one coat of Ist grade enamel paint over a coate of red oxide primer zinc chrome all as specified and as directed.

53

-

-

... More
M&L preparation of new wooden surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.

40

-

-

... More
S&F of 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.

7.5

-

-

... More
S&F PVC (SWR) bends 110mm dia complete all as specified and as directed.

6

-

-

... More
Dismantling of wall & celling boards (fiber pulp insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets.

44.5

-

-

... More
S&F 605 X605 mm GI frame work for for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to sorrounding wall using nylon sleeves and screws at 450 mm centre to centre /intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from suffit at approx 900 mm centre to centre with GI cleats and steel expansion fastner with and including ceiling section (not exc 1.2 m length)of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10 .5 mm fixed to the intermediate channel with connecting clieats across the intermediate channel at 457 mm centre to centre.

44.5

-

-

... More
S&F 10mm thick PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and drawing complete all as specified and directed.

44.5

-

-

... More
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed.

56

-

-

... More
M&L for Point wiring complete with 1.5 sqmm single core PVC insulated and PVC unsheathed FRLS multistranded copper conductor cable 1100 volt grade enclosed in and including PVC casing and capping with accessories fixed on surface on walls/ceiling by means of PVC sleeves, Dash fastners and cadmium plated screws including sunken junction box not less than 3.0 mm thick concealed in wall, mounting accessories like switches, sockets fan regulators with 3.0 mm thick Laminated sheet top covers etc including 1.5 Sqmm single core multi stranded copper conductor PVC insulated and unsheathed cable as earth continuity conductor to common earth dolly complete all as specified and directed.

30

-

-

... More
All as per item No.85 here – in – before but for one 3 / 5 -pin switch socket outlet 5 amps on independent board complete all as specified and directed.

10

-

-

... More
All as per item No.85 here – in – before but for one 3 / 5 -pin switch socket outlet 5 amps on same board complete all as specified and directed.

10

-

-

... More
All as per item No.85 here – in – before but for one switch socket outlet 15 Amps on independent board with 2.5 Sqmm multi stranded and 2.5 Sq mm stranded (for earth) PVC insulated un-sheathed copper cable complete all as specified and directed.

6

-

-

... More
Supply and fix switch piano flush button, single pole, 5 amps, one way all as specified and as directed.

30

-

-

... More
Supply & Fixing ceiling rose surface bakelite 65 X 50 mm three terminal all as specified and as directed.

22

-

-

... More
Supply and fix switch socket combination 2 – in – one, 3 Pin / 5 Pin, 5 amps flush type all as specified and as directed.

20

-

-

... More
Supply and fixing switch socket combination 2 – in – one 6 Pin , 5 / 15 amps flush type universal all as specified and as directed.

6

-

-

... More
Supply and fixing energy efficient LED tube lights fitting 4", 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.

18

-

-

... More
Supply and fixing LED light fitting 1x9W/10W bulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete including taking down old unsv fitting complete all as specified and directed.

2

-

-

... More
S&F lamp/angle holder insulated body with back plate for batten fitting all as specified and as directed.

8

-

-

... More
S & F in LED retro fit lamp B-22 holder base with poly carbonate body and aluminium heat shrink of 12 W complete all as directed.

8

-

-

... More
M&L for Earthing in repairs complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC (1 : 3 : 6) type C-1 , 50 mm thick pre cast RCC (1 : 2 : 4) type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I including taking down existing earthing set and as directed.

1

-

-

... More
M&L for earthing and material and labour for earthing complete wih galvanised steel earth plate electrode 60cmx60cmx6.00 mm thick burried directly in ground vertically toa depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level connected to and including galvanized iron earth strip of size 32x6 mm by means of bolts, nuts , chucknut, and washer etc , made of GI and connecting to earth test point all as shown as electrical plate to 5 of SSR Pt -1 2009 an as specified or indicated and testing on completion including earth work and excavation in any type of soil PCC (1:3:6) type C-I earthing chamber, precast RCC slab 50 mm thick in cement concrete (1:2:4) type B1 reinforced with welded steel wire fabricated weight not less than 4 Kg/ Sqm . Funnel with GI watering pipe 20 mm bore medium grade wire mesh test point etc , complete all as specified.

6

-

-

... More
S&F LED security light suitable for 35 W LED with pressure di cast housing with epoxy power coated drak graphite grey colour finish , Prismatic ploycarbonate cover with individual LED lenses, IP65 by using 25mm dai GI bracked fixed on wall by means of nuts, botls and clamps complete all as specified and directed.

2

-

-

... More
M&L Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 4 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the concealed to wall/ceiling including one run of 4 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor. [NOTE : Two runs of single core 4 sqmm and one run of 4 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.]

10

-

-

... More
S&F Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 12 way 240 Volts AC complete all as specified and directed.

1

-

-

... More
Supply and fix MCB single pole (SP), 10 kA of 5 -32 Amps capacity 240 Volts, 'C' curve complete all as specified and directed.

10

-

-

... More
Supply and fix MCB single pole neutral, 10 kA of 40-63 Amps capacity 240 Volts, 'C' curve complete all as specified and directed.

1

-

-

... More
S&F aluminum strip 25 x 3.15 mm complete with saddles and fixing screws for roof / down conductor on porcelain/epoxy spacer insulatoror fixed on GI Pipe all as specified and as directed (Spacer insulator measured and paid separately under relevant items) . Note :- Rates quoted by the contractor are deemed to be included for cutting ,jointing pieces ofstrip with nut bold etc. complete all as specified and directed.

227

-

-

... More
S&F porcelain/epoxy white / brown / green spacer insulator with one GI stud bolt with nut and washer with necessary drilling for bolt hole for holding / fixing roof conductor / down conductor of lightning conductor complete all as specified and as directed.

190

-

-

... More
S&F single pointed air termination Copper rod 12-mm dia 300 mm long with fixing arrangement including dismantling of old unserviceable/ deshaped conductor and removed from site of work complete all as specified and as directed.

36

-

-

... More
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
M& L for laying GI tubes light grade, 25 mm dia for protection of earth continuity leads all as specified and directed.

40

-

-

... More
Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n'exc. 1.50m deep for LT under ground cable/pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed by Engineer-in- Charge.

4.73

-

-

... More
Returning filling including spreading leveling watering and well ramming in layers not exc 25 cm in soft/ loose soil, complete all as specified and directed.

3.31

-

-

... More
Removing excavated material in soft/ loose soil n'exc 50M and depositing where directed at a level n'exc1.5M above the starting point, complete all as specified and directed.

1.42

-

-

... More
M&L for sand cushioning to U/G cable in layers of 23cm thick( 8 Cm before laying the cable and 15Cm thick after laying the cable) in trenches complete all as specified and directed. Note :- Only Punned layers shall be measured.

2.16

-

-

... More
Supply and laying reinforced precast concrete cable cover class LV type 1 flaat size 250mmx150mmx40mm laid in trenches for cable protection complete all as specified and directed by Engineer-in-charge.

230

-

-

... More
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall with the help of shadel of size 25 Sqmm 4.0 core as required at site.

50

-

-

... More
M & L GI tube light grade for passing through cables under the floor ,along the wall or along the pole of 25 mm bore and fixed to the poles/walls with suitable size of MS clamps and nut and botls/washers etc complete all as specified and as directed.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.