Military Engineer Services Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Solar Installation and Products
Electrical Works
Eprocure
Opening Date6 Dec 2024
Closing Date4 Jan 2025
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply only the followings (To be measured only when incorporated against item No 3.00 here-in- before)

-

-

-

... More
LED Driver (BIS approved) Suitable to existing 30 Watt Street Light Fitting of any make and any type

20

-

-

... More
LED Driver (BIS approved) Suitable to existing 45-60 Watt Street Light Fitting of any make and any type

20

-

-

... More
LED Driver (BIS approved) Suitable to existing 70-90 Watt Street Light Fitting of any make and any type

20

-

-

... More
LED Driver (BIS approved) Suitable to existing garden light/Bollard light fitting upto 25 Watt of any make and any type

20

-

-

... More
LED Driver (BIS approved) Suitable to existing Gate Light fitting upto 30 Watt of any make and any type

20

-

-

... More
LED Driver (BIS approved) Suitable to existing Post Top light fitting upto 30 Watt of any make and any type

20

-

-

... More
LED Driver (BIS approved) Suitable to existing Post Top light fitting upto 30 Watt of any make and any type

20

-

-

... More
LED Driver (BIS approved) Suitable to existing Flood Light fitting upto 70 Watt of any make and any type

20

-

-

... More
LED Driver (BIS approved) Suitable to existing Flood Light fitting above 70 watt and upto 90 watt Watt of any make and any type

20

-

-

... More
LED Driver (BIS approved) Suitable to existing Flood Light fitting above 90 watt and upto 150 watt Watt of any make and any type

20

-

-

... More
LED Driver (BIS approved) Suitable to existing Flood Light fitting above 150 watt and upto 250 watt Watt of any make and any type

20

-

-

... More
FRLS PVC insulated copper conductor, Three core, for street light from box to Street light of 1.5 sqmm size

400

-

-

... More
Bulb Holder brass type

30

-

-

... More
Bulb Holder PVC type

30

-

-

... More
S&F in repairs MCB, Single Pole , 5-32 Amp, 240 volts, AC, 50 Hz, 10 kA breaking capacity(C-curve characteristics) all as specified and directed by Engineer-in-Charge.

15

-

-

... More
S&F in repairs MCB, TPN , 32 Amp, 240 volts, AC, 50 Hz, 10 kA breaking capacity(C-curve characteristics) all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F in repairs MCB, TPN , 40-63 Amp, 240 volts, AC, 50 Hz, 10 kA breaking capacity(C-curve characteristics) all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F in repairs Digital time switch with Astronomical Function for switching on/off lights16A - 250 VA, 50/60 Hz,

5

-

-

... More
S&F in repairs Digital time switch for switching on/off lights16A - 250 VA, 50/60 Hz,

5

-

-

... More
S&F in repairs Power Contactor AC1 32 Amp with Aux Contact NO 230 Volt coil Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1

5

-

-

... More
S&F in repairs Power Contactor AC1 55 Amp with Aux Contact NO 230 Volt coil Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1

5

-

-

... More
S&F in repairs Power Contactor AC1 100Amp with Aux Contact NO 230 Volt coil Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1

5

-

-

... More
S&F in repairs SMC Junction box, 415 V, ,including four busbar of 100 Amp rating, cable glands, Busbar base, of size 295 X 255 X 120 etc

40

-

-

... More
S&F Cable Junction Box 200X160X98mm in size, made out of thermoplastic, having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 -02 No & M-25 -01 No) fixed on poles with Aluminium clamps of size 25x3mm, nuts, bolts, washers etc. including taking out of old unserviceable cable junction box complete all as specified and as directed.

30

-

-

... More
S&F in repairs LED Indicator RYB for timer Panel

30

-

-

... More
M&L Street Light Fittings Bracket, fabricated from GI Pipe 40mm Bore (dia), Light Grade, 1..00 METRE long, bend to required shape and fixing with and including Mild Steel Flat Iron Clamps 40X5mm of suitable Length, 2 No. Nuts, Bolts, Washers, etc., to Pole, applying Painting with One Coat of Red Oxide Zinc Chrome Primer and over Two Coats of Aluminium Paint to Mild Steel Works including Taking down old unserviceable Street Light Fittings Bracket, complete all as specified and as directed.

22

-

-

... More
Supply & fixing LED security light 45 watt (Min) 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with BIS approved driver and lamp, Aluminum die cast housing High efficiency long life LED package in integral module with lumen efficacy of 115 lm/W (Min) and viewing angle of 45 degree to ensure better uniformity, electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test as per latest IS. operational voltage of 170 volts to 270 volts, frequency of 50 Hz, protection grade IP 66, IK-08 CRI greater than or equal to 70% , CW available CCT of 5700K/6500K, power factor of minimum 0.95 , life span of minimum 50000 working hours cincluding necessary electrical connections by PVC sheathed copper conductor wire of 3 core x 1.5 Sqmm and necessary fixing arrangement all as specified. Note : (i) The minimum requirement of lumen efficiency, lumen output and power consumption has been specified. However, as per availability, the bidders may opted higher specification with out any extra cost. The quoted rate is deem to be included for that and no extra payment will be made on this account. (ii) The fittings should be marked 'Date of installation" and "Date of Procurement" with marker pen

25

-

-

... More
All as per BOQ Item No 17.00 here-in-before but of capacity 60 watt.

25

-

-

... More
All as per BOQ Item No 17.00 here-in-before but of capacity 70 watt.

25

-

-

... More
All as per BOQ Item No 17.00 here-in-before but of capacity 90 watt.

15

-

-

... More
All as per BOQ Item No 17.00 here-in-before but of capacity 120 watt.

12

-

-

... More
All as per BOQ Item No 17.00 here-in-before but of capacity 120 watt, LED flood light fittings with lumen efficacy of 120 lm/W (Min)

5

-

-

... More
All as per BOQ Item No 17.00 here-in-before but of capacity 150 watt, LED flood light fittings with lumen efficacy of 120 lm/W (Min)

5

-

-

... More
All as per BOQ Item No 17.00 here-in-before but of capacity 200 watt, LED flood light fittings with lumen efficacy of 120 lm/W (Min)

5

-

-

... More
All as per BOQ Item No 17.00 here-in-before but of capacity 250 watt, LED flood light fittings with lumen efficacy of 120 lm/W (Min)

3

-

-

... More
S&F LED Bollard lights fitting of capacity 09 W die-cast aluminium body, 09 watt LED 3000/5700K and acrylic diffuser complete with all accessories incl taking out old unserviceable one complete all as specified and directed.

5

-

-

... More
Supply & Fix garden light 10watt Decorative warm white IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360º light distribution with all accessories incl taking out old unserviceable one complete all as specified and directed.

5

-

-

... More
S & Fix 15W IP 65 LED post-top aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete with all accessories incl taking out old unserviceable one complete all as specified and directed.

5

-

-

... More
Supply & Fix 25W WH /WW IP 65 LED post-top made in die-cast alumimium bottom housing and spun aluminium to reflector with decrorative clear acrylic diffuser and opal diffuser CCT 3300K for WW/5700K for WH complete with all accessories incl taking out old unserviceable one complete all as specified and directed.

5

-

-

... More
Supply & Fix 40W WH /WW IP 65 LED post-top made in spun aluminium powder coated housing with 5700K complete with all accessories incl taking out old unserviceable one complete all as specified and directed.

5

-

-

... More
S & F including galvanised or codmium plated high tensile Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long of 5 to 10mm dia of neck

2

-

-

... More
S&F in replacement LED aviation light luminaries comprising of alluminium housing with polycarbonate encloser with 302 nos LED ,including cable for connection after taking down old unserviceable light fittings, complete all as specified and directed.

2

-

-

... More
Taking down lumanaries of High Mast and servicing/greasing the motor, gear, Chain,all moving part etc and restoring the lumanaries after necessary repair and replacement of parts, to top of the mast of pole,canopy fixing bracket including charges for machinery/hydra required for fixing at top position as directed. Note:Spare parts shall be measured and paid separately

7

-

-

... More
Supply only the followings (To be measured only when incorporated against item No 33.00 here-in- before)

-

-

-

... More
chain with existing size

6

-

-

... More
Flexible rubber type insulated Copper cable of size 4 Sqmm 4 Core for high mast

30

-

-

... More
Flexible rubber type insulated Copper cable of size 6 Sqmm 4 Core for high mast

30

-

-

... More
Rewinding of three phase motor of capacity 1HP/1.5HP after taking down from existing location and refixing the same after repair complete all as specified and directed.

5

-

-

... More
Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soil Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding.

184.28

-

-

... More
Disconnecting & taking out defective under ground LT cable from trenches, pole, pipe, floor ,wall etc including bricks ,GI pipes and removing from work site of unserviceable material all as specified and directed. (Excavation/earth work shall be measured & paid separately under relevant item of this schedule)

1300

-

-

... More
Supply, Laying, testing and connecting XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 3.5 core 50 sqmm. , laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including Brass Compression Cable Gland, Terminal Lugs,clamps,nut & bolts etc all as specified

100

-

-

... More
All as per BOQ Item No 38.00 here-in-before but of size 3.5 core 35 sqmm, complete all as specified and directed

100

-

-

... More
All as per BOQ Item No 38.00 here-in-before but of size 4.0 core 25 sqmm, complete all as specified and directed

100

-

-

... More
All as per BOQ Item No 38.00 here-in-before but of size 4.0 core 16 sqmm complete all as specified and directed

100

-

-

... More
All as per BOQ Item No 38.00 here-in-before but of size 4.0 core 10 sqmm complete all as specified and directed

300

-

-

... More
All as per BOQ Item No 38.00 here-in-before but of size 2.0 core 10 sqmm complete all as specified and directed

100

-

-

... More
Laying only and connecting XLPE sheathed,PVC insulated screened steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 3.5 core 35-70 sqmm,. , laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including Brass Compression Cable Gland, Terminal Lugs,clamps,nut & bolts etc all as specified

250

-

-

... More
All as per BOQ Item No 44.00 here-in-before but of size 10-25 sqmm, 2 to 4 core ,complete all as specified

250

-

-

... More
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to 18 cm thickness complete all as specified and as directed.(Compacted thickness shall be measured)

73.71

-

-

... More
Supply and laying fly ash best quality, laid in trenches, perpandicular to U/G cable for cable protection complete all as specified.

3960

-

-

... More
Laying only old bricks obtained from item No 37.00 perpandicular to U/G cable for cable protection complete all as specified.

3960

-

-

... More
Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed .

110.33

-

-

... More
Removing excavated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed .

73.72

-

-

... More
M & L for Boring of horizontal hole under road, pavement, hardstanding suitable for passing through up to 100-150 mm bore, complete all as specified. Note : (i) One run of boring of horizontal hole will be measured as one unit length. (ii) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (iii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor. No extra cost will be paid on this account. (iv) Contractor has to get the survey of route, length and depth for boring before quoting the rate.

12

-

-

... More
Cutting through existing PCC/floor/Footpath approx size width 15cm X 60cm depth as required for Realying/Laying of cable/ pipe etc and making good with and including PCC 1:2:4 type B1 complete all as specified and as directed by Engineer-in-charge.

24

-

-

... More
Supplying and fixing High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 complete with all fittings of 50 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable protection complete all as specified and directed.

30

-

-

... More
Supplying and fixing High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 complete with all fittings of 40 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable protection complete all as specified and directed.

30

-

-

... More
M&L for straight through joint (heat shrinkable) complete suitable for LT 1100 Volt aluminium conductor cable of size3.5/4 x 10-16 sqmm and testing after jointing of following sizes of cables. Note Payment will be released only after submission of PV anf test certificate

12

-

-

... More
M&L for straight through joint (heat shrinkable) complete suitable for LT 1100 Volt aluminium conductor cable of size3.5/4 x 25-50 sqmm and testing after jointing of following sizes of cables, Note Payment will be released only after submission of PV anf test certificate

12

-

-

... More
Material and labour for steel tubular poles complete with cast iron base palate, final taper plug bolts, nuts & screws as specified type 410 SP-31, 9.0 meter long including painting all external exposed steel surfaces with two coats of aliminium paint over a coat of red oxide zinc chrome primer and all internal surfaces and external surfaces in contact with concrete with two coats of black bitumenous paint complete all as specified and as directed including taking down old existing concrete poles / struts any size after demolition of foundation and depositing / stackingat a place where directed within 5kM distance from the work site complete allas directed.The remaining external position shall be painted with two coat of aluminium paint including numbering to pole complete all as specified and as directed by Engr-in-Charge. (Note:- Earth work, PCC work, shall be measured and paid separately.)

4

-

-

... More
All as per BOQ Item No 57.00 here-in-before but of SP-22, 8.5 meter long

10

-

-

... More
M&L for cement concrete ( 1:3:6) type C-2 using 40mm graded crushed stone aggregate as in pole foundation, filling and mass concrete complete all as specified

10

-

-

... More
M&L for cement concrete ( 1:2:4) type B-1 using 20mm graded crushed stone aggregate as in coping of pole including weathering, slightly rounded or chamfered angles and throating, necessary formwork as directed complete all as specified

2

-

-

... More
M & L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections includings nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts, in any shape of size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint including preparation of surfaces complete all as specified and directed including taking out the existing one

1

-

-

... More
M & L Painting of steel pole (swan neck type or straight type) up to 12 mtr height with cross arms, clamp of any length and shape for LT overhead line/ for street light with two coat of aluminium paint after scraching out old paint, cleaning and exiting surface rust free, preparation of the existing surface, including marking pole numbers in a 15 cm dia yellow circle with number writting with black syenthic paint/ Stricker, including painting strips in alternate from bottom to top with three strips of black syenthatic paint & two strips of Yellow/ Sky blue paint (as per existing pattern through out the circumference of pole, including removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat of white washing on PCC copping of pole and re-numbering of pole with approved size of letter ( Example - P- 001) with synthetic enamel paint of white colour background and black colour lettering complete all as specified and as directed.

70

-

-

... More
Material and labour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mm mm buried directly in ground (Earth pit not less than 2.25m below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI strip 32x6 mm as earth lead by means of bolt, nuts, check nuts and washers of galvanised iron or steel, upto 7.5m length, earth strip protected by and including 40 mm dia GI pipe (light grade) and connected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC (1:3:6) type C1 , Precast RCC (1:2:4) Type B1 cover slab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100 mm C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm bore GI Pipe (Medium Grade) for watering, Charcoal and salt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any type of soil and disposal of spoil to a distance n.exc 50 m and necessary testing complete all as shown in Electrical Plate No 3 of SSR Part-I. NOTE : 1. The unit rare includes for protectionh GI pipe of 40mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI strip of 32x6mm including protection pipe, from top of earth plate upto 7.5 meter above/below ground level is deemed to be included in the unit rate. 4. All the joints in GI strip and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate

7

-

-

... More
All as per BOQ Item No 63.00 here-in-before but connected to GI wire 4 mm as earth lead by means of bolt, nuts, check nuts and washers of galvanised iron or steel, upto 7.5m length, earth wire protected by and including 15 mm dia GI pipe (light grade)

22

-

-

... More
Dismantling carefully tilted LT street light pole by demolition of coping and foundation and taking out the existing Pole carefully after disconnecting and removing all serviceable fitting like bracket, street light etc, and refixing the pole in same position after necessary eartwork including fixing all accessories (bracket light etc) and necessary connection complete including painting all external exposed steel surfaces with two coats of aliminium paint over a coat of red oxide zinc chrome primer and all internal surfaces and external surfaces in contact with concrete with two coats of black bitumenous paint complete all as specified and as directed .The remaining external position shall be painted with two coat of aluminium paint including numbering to pole complete all as specified and as directed by Engr-in-Charge. (Note:- PCC work, shall be measured and paid separately.)

4

-

-

... More
Supply, install, testing & commission outdoor type, factory made , dust and vermin proof, cubical type Bus bar box of size 0.45m x 0.15m x 0.45m, with canopy fabricated from 3.00 mm thick CRCA sheet for outer shell and 2 mm thick for non load bearing with angle iron frame of 50 x 50 x 6 mm, double door, front and back openable type, double door system, hinged opening, rubber lining, locking arrangement, with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade, protection class IP-66 with and including 4 Nos of bus bar rated 400 Amps made of copper ETP grade including suitable aluminium earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper lugs, making electrical connection PCC foundation and pedestal for fixing bus bar chamber with PCC 1:3:6, 15 cm thick in foundation, brick (Fly ash) / PCC block work in CM 1:6, rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grounting bolts etc for bus bar chamber The platform shall be of 600 mm height above ground level all as specified with supply and fixing the following accessories including taking out the existing one :

4

-

-

... More
M & L for shifting of LT feeder Pillar Box from existing place to specified place including dismantling of all accessories of Panel alongwith its all accessories of any size any type and angle irons, PCC demolition, disconnecting all connections of cables of any size/type and re-installation, testing ,refixing the all accessoies with new copper wiring and necessary connection with the existing cables etc at specifide location and transportation all as specified and directed. Note: (a)Any damage of accessories shall be the responsibilty of contractor and repalcement against damged item shall be done by the contractor without any cost effect. (b) Earth work and PCC work shall be paid and measured seperately.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.