Military Engineer Services Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Services
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date5 Nov 2024
Closing Date4 Dec 2024
Tender Amount₹ 28,80,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply only Air Filter Element complete

2

-

-

... More
Supply only 'V' Belt of existing size

2

-

-

... More
Supply only Hose for water pipe complete set of existing size

2

-

-

... More
Comprehensive maintenance & service charges for carring out 'C' check of DG sets from authorised rep or service enginner from the OEM of DG Set of 125 KVA consisting of normal repairs with periodical routine maintenance, attending breakdown as and when required and testing of DG set complete i.e. Engine, Alternator etc including all consumables items like cotton, waste cloth, kerosene oil etc. Maintenance will be carried out,cleaning of Fuel tank, Adjusting valve tappet/governor clearence/timing, Injector pressure test, cleaning and repairing, tightining mounting screws & nuts fasteners and making lubrication leak proof and replacement of worn out /unserviceble part, checking of vibration damper, checking turbo charger, replecement of fitter & oil, checking inlet & Exhaust manifold cap, screws, checking of fan hub & water pump, removing the existing unservicable engine oil, clear the oil sump & refilling with required quantity of new oil coolent top up, charging the battery, filling the distilled water, cleaning the radiator fan by using blower/ inside tank with solution (costic soda with water) to the entire satisfection of Engr-in-Charge, trial & testing etc complete all as specified and directed. NOTE (I):- Change/top up of Engine oil, Coolent, Costic Soda Solution, element Oil Filter element, Fuel filter element,air filter element, fuel flexible pipe, V belt for water pump and alternator,will be measured in respective items and paid separately. (ii) :- Labour charges for dismantling / taking down and replacement/refixing new parts as and when required is deemed to be included in unit rate quoted. (iii) Any other check as per manufacture's instructions/Engr-in-Charge direction shall be carried out by the contractor and the same are included in unit rate quoted by bidder. (iv) Spares mentioned under item No. 8 to 12 will not included in unit rate of item no 7.00 but if required will be paid under respective items. Capacity- 125 KVA DG Set Make : Greaves Cotton/Kirloskar

4

-

-

... More
Supply only Fuel Filter element

4

-

-

... More
Supply only Lub Oil Filter element

4

-

-

... More
Supply only Air Filter Element complete

4

-

-

... More
Supply only 'V' Belt of existing size

3

-

-

... More
Supply only Hose for water pipe complete set of existing size

3

-

-

... More
Comprehensive maintenance & service charges for carring out 'C' check of DG sets from authorised rep or service enginner from the OEM of DG Set of 100/110 KVA consisting of normal repairs with periodical routine maintenance, attending breakdown as and when required and testing of DG set complete i.e. Engine, Alternator etc including all consumables items like cotton, waste cloth, kerosene oil etc. Maintenance will be carried out,cleaning of Fuel tank, Adjusting valve tappet/governor clearence/timing, Injector pressure test, cleaning and repairing, tightining mounting screws & nuts fasteners and making lubrication leak proof and replacement of worn out /unserviceble part, checking of vibration damper, checking turbo charger, replecement of fitter & oil, checking inlet & Exhaust manifold cap, screws, checking of fan hub & water pump, removing the existing unservicable engine oil, clear the oil sump & refilling with required quantity of new oil coolent top up, charging the battery, filling the distilled water, cleaning the radiator fan by using blower/ inside tank with solution (costic soda with water) to the entire satisfection of Engr-in-Charge, trial & testing etc complete all as specified and directed. NOTE (I):- Change/top up of Engine oil, Coolent, Costic Soda Solution, element Oil Filter element, Fuel filter element,air filter element, fuel flexible pipe, V belt for water pump and alternator,will be measured in respective items and paid separately. (ii) :- Labour charges for dismantling / taking down and replacement/refixing new parts as and when required is deemed to be included in unit rate quoted. (iii) Any other check as per manufacture's instructions/Engr-in-Charge direction shall be carried out by the contractor and the same are included in unit rate quoted by bidder. (iv) Spares mentioned under item No. 14 to 18 will not included in unit rate of item no 13.00 but if required will be paid under respective items. Capacity- 100/110 KVA DG Set Make : Greaves Cotton/Kirloskar

3

-

-

... More
Supply only Fuel Filter element

3

-

-

... More
Supply only Lub Oil Filter element

3

-

-

... More
Supply only Air Filter Element complete

2

-

-

... More
Supply only 'V' Belt of existing size

2

-

-

... More
Supply only Hose for water pipe complete set of existing size

2

-

-

... More
Comprehensive maintenance & service charges for carring out 'C' check of DG sets from authorised rep or service enginner from the OEM of DG Set of 75 to 82.5 KVA consisting of normal repairs with periodical routine maintenance, attending breakdown as and when required and testing of DG set complete i.e. Engine, Alternator etc including all consumables items like cotton, waste cloth, kerosene oil etc. Maintenance will be carried out,cleaning of Fuel tank, Adjusting valve tappet/governor clearence/timing, Injector pressure test, cleaning and repairing, tightining mounting screws & nuts fasteners and making lubrication leak proof and replacement of worn out /unserviceble part, checking of vibration damper, checking turbo charger, replecement of fitter & oil, checking inlet & Exhaust manifold cap, screws, checking of fan hub & water pump, removing the existing unservicable engine oil, clear the oil sump & refilling with required quantity of new oil coolent top up, charging the battery, filling the distilled water, cleaning the radiator fan by using blower/ inside tank with solution (costic soda with water) to the entire satisfection of Engr-in-Charge, trial & testing etc complete all as specified and directed. NOTE (I):- Change/top up of Engine oil, Coolent, Costic Soda Solution, element Oil Filter element, Fuel filter element,air filter element, fuel flexible pipe, V belt for water pump and alternator,will be measured in respective items and paid separately. (ii) :- Labour charges for dismantling / taking down and replacement/refixing new parts as and when required is deemed to be included in unit rate quoted. (iii) Any other check as per manufacture's instructions/Engr-in-Charge direction shall be carried out by the contractor and the same are included in unit rate quoted by bidder. (iv) Spares mentioned under item No. 20 to 24 will not included in unit rate of item no 19.00 but if required will be paid under respective items. Capacity- 75 to 82.5 KVA DG Set Make : Greaves Cotton/Kirloskar/Mahindra Powerol

8

-

-

... More
Supply only Fuel Filter element

8

-

-

... More
Supply only Lub Oil Filter element

8

-

-

... More
Supply only Air Filter Element complete

8

-

-

... More
Supply only 'V' Belt of existing size

4

-

-

... More
Supply only Hose for water pipe complete set of existing size

3

-

-

... More
Comprehensive maintenance & service charges for carring out 'C' check of DG sets from authorised rep or service enginner from the OEM of DG Set of 62/62.5 KVA consisting of normal repairs with periodical routine maintenance, attending breakdown as and when required and testing of DG set complete i.e. Engine, Alternator etc including all consumables items like cotton, waste cloth, kerosene oil etc. Maintenance will be carried out,cleaning of Fuel tank, Adjusting valve tappet/governor clearence/timing, Injector pressure test, cleaning and repairing, tightining mounting screws & nuts fasteners and making lubrication leak proof and replacement of worn out /unserviceble part, checking of vibration damper, checking turbo charger, replecement of fitter & oil, checking inlet & Exhaust manifold cap, screws, checking of fan hub & water pump, removing the existing unservicable engine oil, clear the oil sump & refilling with required quantity of new oil coolent top up, charging the battery, filling the distilled water, cleaning the radiator fan by using blower/ inside tank with solution (costic soda with water) to the entire satisfection of Engr-in-Charge, trial & testing etc complete all as specified and directed. NOTE (I):- Change/top up of Engine oil, Coolent, Costic Soda Solution, element Oil Filter element, Fuel filter element,air filter element, fuel flexible pipe, V belt for water pump and alternator,will be measured in respective items and paid separately. (ii) :- Labour charges for dismantling / taking down and replacement/refixing new parts as and when required is deemed to be included in unit rate quoted. (iii) Any other check as per manufacture's instructions/Engr-in-Charge direction shall be carried out by the contractor and the same are included in unit rate quoted by bidder. (iv) Spares mentioned under item No. 26 to 30 will not included in unit rate of item no 25.00 but if required will be paid under respective items. Capacity- 62/62.5 KVA DG Set Make : Greaves Cotton/Kirloskar/Mahindra Powerol

13

-

-

... More
Supply only Fuel Filter element

13

-

-

... More
Supply only Lub Oil Filter element

13

-

-

... More
Supply only Air Filter Element complete

8

-

-

... More
Supply only 'V' Belt of existing size

7

-

-

... More
Supply only Hose for water pipe complete set of existing size

6

-

-

... More
Comprehensive maintenance & service charges for carring out 'C' check of DG sets from authorised rep or service enginner from the OEM of DG Set of 50/52.5 KVA consisting of normal repairs with periodical routine maintenance, attending breakdown as and when required and testing of DG set complete i.e. Engine, Alternator etc including all consumables items like cotton, waste cloth, kerosene oil etc. Maintenance will be carried out,cleaning of Fuel tank, Adjusting valve tappet/governor clearence/timing, Injector pressure test, cleaning and repairing, tightining mounting screws & nuts fasteners and making lubrication leak proof and replacement of worn out /unserviceble part, checking of vibration damper, checking turbo charger, replecement of fitter & oil, checking inlet & Exhaust manifold cap, screws, checking of fan hub & water pump, removing the existing unservicable engine oil, clear the oil sump & refilling with required quantity of new oil coolent top up, charging the battery, filling the distilled water, cleaning the radiator fan by using blower/ inside tank with solution (costic soda with water) to the entire satisfection of Engr-in-Charge, trial & testing etc complete all as specified and directed. NOTE (I):- Change/top up of Engine oil, Coolent, Costic Soda Solution, element Oil Filter element, Fuel filter element,air filter element, fuel flexible pipe, V belt for water pump and alternator,will be measured in respective items and paid separately. (ii) :- Labour charges for dismantling / taking down and replacement/refixing new parts as and when required is deemed to be included in unit rate quoted. (iii) Any other check as per manufacture's instructions/Engr-in-Charge direction shall be carried out by the contractor and the same are included in unit rate quoted by bidder. (iv) Spares mentioned under item No. 32 to 36 will not included in unit rate of item no 31.00 but if required will be paid under respective items. Capacity- 50/52.5 KVA DG Set Make : Greaves Cotton/Kirloskar

5

-

-

... More
Supply only Fuel Filter element

5

-

-

... More
Supply only Lub Oil Filter element

5

-

-

... More
Supply only Air Filter Element complete

5

-

-

... More
Supply only 'V' Belt of existing size

4

-

-

... More
Supply only Hose for water pipe complete set of existing size

3

-

-

... More
Comprehensive maintenance & service charges for carring out 'C' check of DG sets from authorised rep or service enginner from the OEM of DG Set of 40 KVA consisting of normal repairs with periodical routine maintenance, attending breakdown as and when required and testing of DG set complete i.e. Engine, Alternator etc including all consumables items like cotton, waste cloth, kerosene oil etc. Maintenance will be carried out,cleaning of Fuel tank, Adjusting valve tappet/governor clearence/timing, Injector pressure test, cleaning and repairing, tightining mounting screws & nuts fasteners and making lubrication leak proof and replacement of worn out /unserviceble part, checking of vibration damper, checking turbo charger, replecement of fitter & oil, checking inlet & Exhaust manifold cap, screws, checking of fan hub & water pump, removing the existing unservicable engine oil, clear the oil sump & refilling with required quantity of new oil coolent top up, charging the battery, filling the distilled water, cleaning the radiator fan by using blower/ inside tank with solution (costic soda with water) to the entire satisfection of Engr-in-Charge, trial & testing etc complete all as specified and directed. NOTE (I):- Change/top up of Engine oil, Coolent, Costic Soda Solution, element Oil Filter element, Fuel filter element,air filter element, fuel flexible pipe, V belt for water pump and alternator,will be measured in respective items and paid separately. (ii) :- Labour charges for dismantling / taking down and replacement/refixing new parts as and when required is deemed to be included in unit rate quoted. (iii) Any other check as per manufacture's instructions/Engr-in-Charge direction shall be carried out by the contractor and the same are included in unit rate quoted by bidder. (iv) Spares mentioned under item No. 38 to 42 will not included in unit rate of item no 37.00 but if required will be paid under respective items. Capacity- 40 KVA DG Set Make : Greaves Cotton/Kirloskar/Ashok Leyland

5

-

-

... More
Supply only Fuel Filter element

5

-

-

... More
Supply only Lub Oil Filter element

5

-

-

... More
Supply only Air Filter Element complete

5

-

-

... More
Supply only 'V' Belt of existing size

4

-

-

... More
Supply only Hose for water pipe complete set of existing size

3

-

-

... More
Comprehensive maintenance & service charges for carring out 'C' check of DG sets from authorised rep or service enginner from the OEM of DG Set of 5 to 25 KVA consisting of normal repairs with periodical routine maintenance, attending breakdown as and when required and testing of DG set complete i.e. Engine, Alternator etc including all consumables items like cotton, waste cloth, kerosene oil etc. Maintenance will be carried out,cleaning of Fuel tank, Adjusting valve tappet/governor clearence/timing, Injector pressure test, cleaning and repairing, tightining mounting screws & nuts fasteners and making lubrication leak proof and replacement of worn out /unserviceble part, checking of vibration damper, checking turbo charger, replecement of fitter & oil, checking inlet & Exhaust manifold cap, screws, checking of fan hub & water pump, removing the existing unservicable engine oil, clear the oil sump & refilling with required quantity of new oil coolent top up, charging the battery, filling the distilled water, cleaning the radiator fan by using blower/ inside tank with solution (costic soda with water) to the entire satisfection of Engr-in-Charge, trial & testing etc complete all as specified and directed. NOTE (I):- Change/top up of Engine oil, Coolent, Costic Soda Solution, element Oil Filter element, Fuel filter element,air filter element, fuel flexible pipe, V belt for water pump and alternator,will be measured in respective items and paid separately. (ii) :- Labour charges for dismantling / taking down and replacement/refixing new parts as and when required is deemed to be included in unit rate quoted. (iii) Any other check as per manufacture's instructions/Engr-in-Charge direction shall be carried out by the contractor and the same are included in unit rate quoted by bidder. (iv) Spares mentioned under item No. 44 to 48 will not included in unit rate of item no 43.00 but if required will be paid under respective items. Capacity- 5 to 25 KVA DG Set Make : Greaves Cotton/Kirloskar

3

-

-

... More
Supply only Fuel Filter element

5

-

-

... More
Supply only Lub Oil Filter element

5

-

-

... More
Supply only Air Filter Element complete

5

-

-

... More
Supply only 'V' Belt of existing size

4

-

-

... More
Supply only Hose for water pipe complete set of existing size

3

-

-

... More
Supply & filling of Engine oil 20W40 to topup/ replacement of all DG set of various capacity, model & location as mentioned here-in-before as per the standard practice, complete all as specified and directed.

700

-

-

... More
Supply & filling of Coolant suitable for DG set of various capacity, model & location as mentioned here-in-before as per the standard practice complete all as specified and directed.

120

-

-

... More
S & F of glass wool insulation (50mm thick), duly wrapped over the exhaust pipe (80 - 100 mm dia) of generating set including cladding over the insulation with aluminium foil tape and taking down old unserviceable complete all as specified and directed. Note :- Length of exhaust pipe shall be taken into account for measurement.

60

-

-

... More
S & F in repair battery, 12 Volt, 150 AH, complete all as specified and directed.

12

-

-

... More
S & F in repair battery, 12 Volt, 88 AH. complete all as specified and directed.

3

-

-

... More
Supply and pouring distilled water & acid mixture for battery and radiator,complete all as specified and directed.

150

-

-

... More
S & F in repairs door lock assembly with keys suitable for aqustic enclosure for D G Sets of any capacity including all accessories complete all as specified and directed.

10

-

-

... More
Repair/Maint of Automatic Battery Charger, I/P-230 Volt, AC, O/P - 12 Volt DC, 10 Amps. and replacement of burn out of electric circuit, unserviceable triodes, unserviceable rectifiers, unserviceable capacitors and resistance etc. after completion of repair work testing complete all as specified and directed. Note:- All the spares part deemed to be included in quoted rate.

10

-

-

... More
Dismantling of radiator assembly of 320KVA from generating set and transportation to the workshop, repair the tank /storage portion incl necessary welding/soldering & making leak proof of the tank, cleaning the complete radiator with chemical agent and pumping set incl replacement of defective copper core and assembling the radiator including replacement of all old rusted MS nuts, bolts washers & gasket sets including refixing and testing complete all as specified and directed.

1

-

-

... More
Dismantling of radiator assembly of 125KVA /100/110KVA from generating set and transportation to the workshop, repair the tank /storage portion incl necessary welding/soldering & making leak proof of the tank, cleaning the complete radiator with chemical agent and pumping set incl replacement of defective copper core and assembling the radiator including replacement of all old rusted MS nuts, bolts washers & gasket sets including refixing and testing complete all as specified and directed.

3

-

-

... More
Dismantling of radiator assembly of 75/82.5KVA /62.5/63KVA from generating set and transportation to the workshop, repair the tank /storage portion incl necessary welding/soldering & making leak proof of the tank, cleaning the complete radiator with chemical agent and pumping set incl replacement of defective copper core and assembling the radiator including replacement of all old rusted MS nuts, bolts washers & gasket sets including refixing and testing complete all as specified and directed.

12

-

-

... More
Dismantling of radiator assembly of 50/40KVA from generating set and transportation to the workshop, repair the tank /storage portion incl necessary welding/soldering & making leak proof of the tank, cleaning the complete radiator with chemical agent and pumping set incl replacement of defective copper core and assembling the radiator including replacement of all old rusted MS nuts, bolts washers & gasket sets including refixing and testing complete all as specified and directed.

6

-

-

... More
Dismantling of radiator assembly of 25/35KVA from generating set and transportation to the workshop, repair the tank /storage portion incl necessary welding/soldering & making leak proof of the tank, cleaning the complete radiator with chemical agent and pumping set incl replacement of defective copper core and assembling the radiator including replacement of all old rusted MS nuts, bolts washers & gasket sets including refixing and testing complete all as specified and directed.

2

-

-

... More
S & F in repairs of radiator pump of any capacities installed at DG sets at different locations including replacement of all old rusted MS nuts, bolts washers & gasket sets including refixing and testing complete all as specified and directed.

10

-

-

... More
S & F in repairs of radiator fan of any capacities installed at DG sets at different locations including replacement of all old rusted MS nuts, bolts washers & gasket sets including refixing and testing complete all as specified and directed.

8

-

-

... More
Finding out defects of Fully Automatic Electric panel (AMF) suitable for 125/110/100KVA DG set and taking out burnt interconnection wiring including u/s sensor, relay etc and serviceable components for reuse including Rewiring of damaged portion of panel using existing size of copper cable, ferrule, lugs, insulating material, nut bolt washer of various sizes including supply and fix new relay of existing model, refixing serviceable items, calibration and testing complete all as specified and directed. Note:- All the spares part deemed to be included in quoted rate.

7

-

-

... More
Finding out defects of Fully Automatic Electric panel (AMF) suitable for 75/82.5/62.5/63 KVA DG set and taking out burnt interconnection wiring including u/s sensor, realy etc and serviceable components for reuse including Rewiring of damaged portion of panel using existing size of copper cable, ferrule, lugs, insulating material, nut bolt washer of various sizes including supply and fix new relay of existing model, refixing serviceable items and testing complete all as specified and directed. Note:- All the spares part deemed to be included in quoted rate.

4

-

-

... More
Disconnecting the self starter(12V/24V) from the engine body,dismantling the same,checking for identification of faulty spares and reassembling the same after replacement of faulty/Unserviceable spare parts, if required,including refixing to its original position (for 320 KVA DG), complete all as per specified and directed. Note - S & F spare required to be replaced shall be measured and paid separately as below.

1

-

-

... More
S&F clutch assembly, complete all as specified and directed.

1

-

-

... More
S&F Bendex pinion, complete all as specified and directed.

1

-

-

... More
S &F Solenoid switch, complete all as specified and directed.

1

-

-

... More
S&F Carbon Brush, complete all as specified and directed.

1

-

-

... More
S&F Armature Field Coil, complete all as specified and directed.

1

-

-

... More
S&F Bush, complete all as specified and directed.

1

-

-

... More
Self armature coil, complete all as specified and directed.

1

-

-

... More
Disconnecting the self starter(12V/24V) from the engine body,dismantling the same,checking for identification of faulty spares and reassembling the same after replacement of faulty/Unserviceable spare parts, if required,including refixing to its original position (for 25 to 125KVA DG), complete all as per specified and directed. Note- S & F spare required to be replaced shall be measured and paid separately as below.

9

-

-

... More
S&F clutch assembly complete all as specified and directed.

4

-

-

... More
S&F Bendex pinion complete all as specified and directed.

4

-

-

... More
S&F Solenoid switch complete all as specified and directed.

4

-

-

... More
S&F Carbon Brush complete all as specified and directed.

3

-

-

... More
S&F Armature Field Coil complete all as specified and directed.

3

-

-

... More
S&F Bush complete all as specified and directed.

2

-

-

... More
Self armature coil complete all as specified and directed.

2

-

-

... More
S&F Power contactor of 200 Amps,4 Pole with 1 NO & 1 NC with auxiliairy contact of coil rating 415 Volt, 50 Hz, Including taking out old unserviceable one, complete all as per specified and directed.

7

-

-

... More
S&F Power contactor of 140/150 Amps, 4 Pole with 1 NO & 1 NC auxilary contacts of coil rating 415 Volt, 50 Hz, Including taking out old unserviceable one, complete all as per specified and directed.

9

-

-

... More
S&F HRC fuse link of rating 400 Amps of breaking capacity of 80 KA & rated voltage 415 Volt of size 02, DIN type, including taking out old unserviceable one, complete all as per specified and directed.

4

-

-

... More
S&F HRC fuse link of rating 250Amps of breaking capacity of 80 KA & rated voltage 415 Volt of size 02, DIN type, including taking out old unserviceable one, complete all as per specified and directed.

5

-

-

... More
S&F HRC fuse link of rating 160Amps of breaking capacity of 80 KA & rated voltage 415 Volt of size 01, DIN type, including taking out old unserviceable one, complete all as per specified and directed.

3

-

-

... More
S & F rotary selector switch Auto/Manual type, complete all as specified and directed.

4

-

-

... More
M&L MCCB 4 Pole 200 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals including taking out existing UNSV / burnt MCCB from site complete all as specified and directed.

5

-

-

... More
M&L MCCB 4 Pole 250 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals including taking out existing UNSV / burnt MCCB from site complete all as specified and directed.

2

-

-

... More
S & F Voltage Monotoring relay suitable for 35 to 320 KVA DG Set, including taking down old unserviceable one, complete all as specified & directed.

7

-

-

... More
S & F in replacement of fuel/over flow pipe for DG set/diesel driven pump set all as specified and directed.

45

-

-

... More
S & F in repairs Battery terminal cable, copper conductor multi strand, unsheathed, single core 16 sqmm, 1.2 mtr long fixed with copper terminals on both side suitable for 12 Volts & upto 150 AH battery both for positive and negative terminal all as specified and directed.

13

-

-

... More
S & F in repairs of automatic voltage regulator for DG set for 320 KVA DG Set complete all as per specified and directed.

1

-

-

... More
S & F in repairs of automatic voltage regulator for DG set for 125 KVA DG Set complete all as per specified and directed.

3

-

-

... More
S & F in repairs of automatic voltage regulator for DG set for 100/110 KVA DG Set complete all as per specified and directed.

1

-

-

... More
S & F in repairs of automatic voltage regulator for DG set for 82.5 KVA DG Set complete all as per specified and directed.

2

-

-

... More
S & F in repairs of automatic voltage regulator for DG set for 75 KVA DG Set all as specified and directed.

1

-

-

... More
S & F in repair of automatic voltage regulator for DG set for 62.5/63KVA ,40/50KVA,25/35KVA DG Set all as specified and directed.

5

-

-

... More
Taking out exhaust silencer box and pipe from the DG set of cap 125KVA to 320KVA, decarburizing and cleaning the silencer box including replacement of nut, bolts, washers clamp/bracket and refixing and wraping with asbestos rope and powder complete all as specified and directed. (Note:- Asbestos rope and powder rate will be inclusive).

2

-

-

... More
Taking out exhaust silencer box and pipe from the DG set of cap 62.5KVA to 110KVA, decarburizing and cleaning the silencer box including replacement of nut, bolts, washers clamp/bracket and refixing and wraping with asbestos rope and powder complete all as per specified and directed. (Note:- Asbestos rope and powder rate will be inclusive).

3

-

-

... More
Taking out exhaust silencer box and pipe from the DG set of cap 25KVA to 52.5 decarburizing and cleaning the silencer box including replacement of nut, bolts, washers clamp/bracket and refixing and wraping with asbestos rope and powder complete all as per specified and directed. (Note:- Asbestos rope and powder rate will be inclusive).

2

-

-

... More
Dismantling turbocharger assembly from the DG set 25 to 82.5 KVA DG Set of from engine, transportation to work shop for repair, cleaning and carrying out inspection of each components/spares segregation of serviceable spares for reuse including decarbonising machine, cutting, grinding polishing etc. and re-assembling the Turbocharger with replacement of spare parts and refixing on existing position complete complete all as per specified and directed. (Note:- Spares required will be measured and paid separately under respective items).

3

-

-

... More
Dismantling turbocharger assembly from the DG set 125 to 320 KVA DG Set of from engine, transportation to work shop for repair, cleaning and carrying out inspection of each components/spares segregation of serviceable spares for reuse including decarbonising machine, cutting, grinding polishing etc. and re-assembling the Turbocharger with spare parts and refixing on existing position complete complete all as per specified and directed. (Note:- Spares required will be measured and paid separately under respective items).

2

-

-

... More
Dismantling turbocharger assembly from the DG set 100 to 110 KVA DG Set of from engine, transportation to work shop for repair, cleaning and carrying out inspection of each components/spares segregation of serviceable spares for reuse including decarbonising machine, cutting, grinding polishing etc. and re-assembling the Turbocharger with spare parts and refixing on existing position complete all as per specified and directed. (Note:- Spares required will be measured and paid separately under respective items).

1

-

-

... More
Dismantling, servicing, testing of nozzle injector assembly of the DG set of under mentioned capacity from engine for repair, cleaning and overhauling of the same with necessary calibration 125 KVA TO 320 KVA DG Set, complete all as per specified and directed.

12

-

-

... More
Dismantling servicing, testing of injector assembly of the DG set of 25 KVA to 110 KVA DG Set from engine for repair, cleaning and overhauling of the same with necessary calibration, complete all as per specified and directed. (Note:- Spares required will be measured and paid separately under respective items).

40

-

-

... More
M & L for replacement of unservicable parts of cylinder liner assembly with the new one, conforming to their respective part Nos for the following mentioned items after dismantling the DG sets incorporated in the above item, and taking out the unservicable parts for the 50KVA to 125 KVA DG set complete all as specified & directed.

4

-

-

... More
All as per Item No. 107, but Piston complete all as per specified and directed.

4

-

-

... More
All as per Item No. 107, but Piston Ring complete all as per specified and directed.

4

-

-

... More
All as per Item No. 107, but CR bearing complete all as per specified and directed.

4

-

-

... More
All as per Item No. 107, but Head Gasket complete all as per specified and directed.

2

-

-

... More
All as per Item No. 107, but Valve inlet complete all as per specified and directed.

4

-

-

... More
All as per Item No. 107, but Valve Guide complete all as per specified and directed.

8

-

-

... More
All as per Item No. 107, but Valve Exhaust complete all as per specified and directed.

4

-

-

... More
All as per Item No. 107, but Oil seal assembly complete all as per specified and directed.

2

-

-

... More
All as per Item No. 107, but Nozzle 'o' Ring complete all as per specified and directed.

2

-

-

... More
All as per Item No. 107, but Hose pipe with clamps complete all as per specified and directed.

2

-

-

... More
All as per Item No. 107, but Thrust Washer complete all as per specified and directed.

4

-

-

... More
All as per Item No. 107, but Nozzle valve complete all as per specified and directed.

4

-

-

... More
All as per Item No. 107, but Fuel pipe (inlet & outlet pair) complete all as per specified and directed.

2

-

-

... More
All as per Item No. 107, but Flexible pipe complete all as per specified and directed.

2

-

-

... More
All as per Item No. 107, but Thermostate valve complete all as per specified and directed.

2

-

-

... More
All as per Item No. 107, but Radiator Fan complete all as per specified and directed.

2

-

-

... More
All as per Item No. 107, but Valve solenoid complete all as per specified and directed.

2

-

-

... More
All as per Item No. 107, but Plunzer fuel control complete all as per specified and directed.

2

-

-

... More
All as per Item No. 107, but Lub oil pipe complete all as per specified and directed.

2

-

-

... More
Dismantling /opening of alternator by disconnection of cable connections and flexible coupling, nuts/bolts and alternator foundation nut, bolts including taken back in temporary platform including strip opening of alternator and checking out burnt out parts for capacity 125KVA to 320 KVA Taking out burnt armature or burnt field coil or both. Rewinding armature coil or field coil or armature coil and field coil with super enamaled copper winding wire of existing guage, weight and turns including insulation of armature/field coil with Class ‘H’ insulation and Varnishing of armature/field coil winding and drying up to desired temperature. Reassembling alternator after rewinding and reasembling with engine including connection of cable connections and flexible coupling, nuts/bolts and alternator foundation nut, bolts etc.testing calibaration and commissining complete all as specified and directed. NOTE (I):- Supply of winding wire, & S&F of rectifier/diode,AVR will be measured in respective items and paid separately. (ii) :- Replacement/refixing new minor parts as and when required is deemed to be included in unit rate quoted. : (iii) :- DG Set Make : Greaves Cotton/Kirloskar

1

-

-

... More
All as per above Item No. 127.00 mentioned here-in-above but for capacity 25 KVA to 110 KVA complete all as specified and directed.

1

-

-

... More
Supply only armature, winding wire and rewinding of armature with super enameled copper winding wire of existing gauge for above wirefor 25 KVA to 320 KVA DG sets. complete all as specified and directed.

65

-

-

... More
Supply only of field coil with super enameled copper winding wire of existing gauge for 25 KVA to 320 KVA DG sets.complete all as specified and directed.

85

-

-

... More
S&F in replacement of burnt rectifier/diode sitable for 25 KVA to 63 KVA DG Sets complete all as per specified and directed.

4

-

-

... More
S&F in replacement of burnt rectifier/diode sitable for 75 KVA to 110 KVA DG Sets complete all as per specified and directed.

5

-

-

... More
S&F in replacement of burnt rectifier/diode sitable for 125 KVA to 320 KVA DG Sets complete all as per specified and directed.

3

-

-

... More
All as per item No 134.00 mentioned here-in-above but AVR of for DG capacity 125 KVA to 320 KVA DG Sets complete all as per specified and directed.

3

-

-

... More
Dismantling for over hauling out Fuel injector pump from DG set carefully, transportation of the same to civil work-shop for repair & complete service of FIP pump and calibration and testing on automatic setting machine, shifting of FIP pump from civil work-shop to site including minor spare and re-fixing the same to DG set and testing complete of range 125 KVA & 320 KVA complete all as per specified and directed.

4

-

-

... More
Dismantling for over hauling out Fuel injector pump from DG set carefully, transportation of the same to civil work-shop for repair & complete service of FIP pump and calibration on automatic setting machine, shifting of FIP pump from civil work-shop to worksite including minor spare and re-fixing the same to DG set and testing complete of range 25 KVA, 40 KVA, 50 KVA, 62.5 KVA, 63 KVA & 82.5 KVA complete all as per specified and directed.

7

-

-

... More
S & F in repair digital multifuntional controller meter of AMF/ control panel which displays voltage, current, KW, PF, Frequency, KWh complete all as specified and as directed.

3

-

-

... More
Finding out defects of DG set Control panel of any capacity and Taking out burnt wiring including u/s and serviceable components for reuse including Rewiring of panel using & providing existing size of copper cable, ferrule, lugs, insulating material, nuts bolts washers etc.of various sizes including testing complete all as specified and directed.

5

-

-

... More
M&L in repairs of ignition switch with key for DG set complete all as specified and directed.

8

-

-

... More
Painting to the DG Sets of any capacities by prepration of old painted surfaces, cleaning & removing of existing rust grease oil spot etc,including minor denting priming with aluminium red-oxide and then applying 1st grade of spray paint (Two Coat) of approved make, brand and colours (includes cost of paint) including fuel tank foundation base and AMF/control panel board complete all as specified and directed.

10

-

-

... More
Dismantling the broken door of sound proof canopy of the DG set of capacity from 40 KVA to 125 KVA if required tranporting to workshop for repair. Repairing the door with new hinges & nut bolts etc and re-assembling the same at existing position & testing for proper opening & closing of the doors, including repair of the locking system complete all as specified and directed. Note : The rate quoted deemed to including rate the cutting / drilling / welding work, if any.

8

-

-

... More
S&F in replacement of dynamo belt as per existing size for DG set of capcity 25 KVA to 320 KVA complete all as specified & directed.

6

-

-

... More
S & F On load Change Over switch rotary type panel mounted in existing panel rating of 200 A , 4 pole , 415 V including elecrical connection with proper lugs after dis connection of elecrical connection taking out old U/SChange Over switch complete all as specified and directed.

1

-

-

... More
S & F On load Change Over switch rotary type panel mounted in existing panel rating of 250 A , 4 pole , 415 V including elecrical connection with proper lugs after dis connection of elecrical connection taking out old unserviceable Change Over switch complete all as specified and directed.

1

-

-

... More
S & F On load Change Over switch rotary type panel mounted in existing panel rating of 400 A , 4 pole , 415 V including elecrical connection with proper lugs after dis connection of elecrical connection taking out old unserviceable Change Over switch complete all as specified and directed.

1

-

-

... More
M&L Earthing complete with GI earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI earth strip of size 32 x 6 mm earth lead by means of nuts, bolts, check nuts, washers of galvanized iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 45 x 45 x 5cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed. (GI strip upto 7.5m including testing is deemed to the included in the item.)

4

-

-

... More
Repair/ maint, servicing, cleaning and descaling of solar heating system of cap.100 Ltr to 200 Ltr and including dismentling and after completion of maint work refixing and testing complete all as specified and directed.

8

-

-

... More
M&L in repair 3KW heating element incuding all connecting assessories complete all as specified and directed.

8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.