Military Engineer Services Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Works
Building Construction
Eprocure
Opening Date20 Dec 2024
Closing Soon26 Feb 2025
Tender Amount₹ 58,30,00,000 
Notes
Download

AI Insights

Class Of Bidder
... View More
The class eligibility requirement to bid or participate in this tender is Class 'SS' and above.
Technical Capacity
... View More
The required prior work experience for contractors not enlisted includes satisfactory completion of requisite value works with certain government entities. The details of works completed and under progress should be submitted, including the value of the work. However, specific values like amount and percentage are not mentioned.

Costs

Summary

80212 Construction Of Otm Accn Including Admin Block And Single

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lump sum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – III on Serial Page No. 39.

1

1038504

-

... More
Lump sum price worked out by the contractor for "INTERNAL ELECTRIC SUPPLY", as listed in Schedule "A" Part – IV on Serial Page No. 44.

1

9859530

-

... More
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY", as listed in Schedule "A" Part – V on Serial Page No. 46.

1

478802

-

... More
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIC SUPPLY, LIFT, DG SET & AVIATION OBSTRUCTION LIGHT", as listed in Schedule "A" Part – VI on Serial Page No. 51.

1

9646303

-

... More
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL", as listed in Schedule "A" Part – VII on Serial Page No. 52.

1

1594740

-

... More
Lump sum price worked out by the contractor for "AREA DRAINAGE", as listed in Schedule "A" Part – VIII on Serial Page No. 53.

1

2132148

-

... More
Lump sum price worked out by the contractor for "PARADE GROUND", as listed in Schedule "A" Part – IX on Serial Page No. 54

1

311767653

-

... More
Lump sum price worked out by the contractor for "BASKET BALL GROUND", as listed in Schedule "A" Part – X on Serial Page No. 55

1

1474348

-

... More
Lump sum price worked out by the contractor for "ROAD, PATH, RAMP & CULVERT", as listed in Schedule "A" Part – XI on Serial Page No. 58

1

10137640

-

... More
Lump sum price worked out by the contractor for "SECURITY WALL", as listed in Schedule "A" Part – XII on Serial Page No. 60

1

44550366

-

... More
Lump sum price worked out by the contractor for "FIRE FIGHTING, FIRE DETECTION AND FIRE ALARM SYSTEM", as listed in Schedule "A" Part – XIII on Serial Page No. 71

1

9475096

-

... More
Lump sum price worked out by the contractor for "TV & TELE SOCKET, CC CAMERA & CONDUIT", as listed in Schedule "A" Part – XIV on Serial Page No. 72

1

390691

-

... More
Lump sum price worked out by the contractor for "LIGHTNING PROTECTION", as listed in Schedule "A" Part – XV on Serial Page No. 73

1

453707

-

... More
Lump sum price worked out by the contractor for "PILE FOUNDATION", as listed in Schedule "A" Part – XVI on Serial Page No. 74

1

78836545

-

... More
Lump sum price worked out by the contractor for "DEMOLITION/ DISMANTLING", as listed in Schedule "A" Part – XVII on Serial Page No. 75

1

1573281

-

... More
Schedule "A" Part - XVIII: [Miscellaneous Items] [Internal Water Supply, Internal Electric Supply, External Water Supply, External Electric Supply, Lift, DG set & Aviation obstruction light, Sewage Disposal, Fire fighting, fire detection & fire alarm system, TV & Tele socket & conduit, Smart metering system]

-

-

-

... More
S&F modular type 3 pin 25 A socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.

55

-

-

... More
S & F modular type 25 A SP MCB, conforming to IS 60898- 1: 2002 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.

55

-

-

... More
S & F 4 Modular Motor Starter, conforming to IS 60898- 1: 2002 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.

19

-

-

... More
S & F USB & C-Type Charger, conforming to IS 60898- 1: 2002 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.

255

-

-

... More
S&F sheet steel powder coated distribution board Vertical type TPN 4 ways, 415 volts, with 200 Amps rated copper bus bar, neutral link, earth bar, IP 43 protection and double door, suitable for mounting 4 pole MCCB up to 160 Amps as incomer and MCBs as out going complete fixed flush to the wall surface all as specified and as directed. [Note: MCCB & MCBs shall be measured and paid separately]

8

-

-

... More
S&F sheet steel powder coated distribution board Vertical type TPN 6 ways, 415 volts, with 200 Amps rated copper bus bar, neutral link, earth bar, IP 43 protection and double door, suitable for mounting 4 pole MCCB up to 160 Amps as incomer and MCBs as out going complete fixed flush to the wall surface all as specified and as directed. [Note: MCCB & MCBs shall be measured and paid separately]

2

-

-

... More
S&F MCB 3 pole 'C' curve, 415 Volts, 16 Amps, 10 KA

15

-

-

... More
S&F MCB 2 pole 'C' curve, 415 Volts, 16-20 Amps, 10 KA

34

-

-

... More
S&F MCB single pole 'C' curve, 240 Volts, 40 Amps, 10 KA

3

-

-

... More
M&L Wiring for circuit/sub main wiring along with earth wire with 4x2.5 sq.mm + 2x2.5 sq.mm for earth wire of 1100 Volts grade FRLSH PVC insulated copper conductor, single core cable in recessed as required drawn in PVC Conduit concealed type all as specified and directed

80

-

-

... More
M&L Wiring for circuit/sub main wiring along with earth wire with 4x4.0 sq.mm + 2x4.0 sq.mm for earth wire of 1100 Volts grade FRLSH PVC insulated copper conductor, single core cable in recessed as required drawn in PVC Conduit concealed type all as specified and directed

30

-

-

... More
M&L Wiring for circuit/sub main wiring along with earth wire with 4x6.0 sq.mm + 2x6.0 sq.mm for earth wire of 1100 Volts grade FRLSH PVC insulated copper conductor, single core cable in recessed as required drawn in PVC Conduit concealed type all as specified and directed

150

-

-

... More
M&L Wiring for circuit/sub main wiring along with earth wire with 4x10.0 sq.mm + 2x10.0 sq.mm for earth wire of 1100 Volts grade FRLSH PVC insulated copper conductor, single core cable in recessed as required drawn in PVC Conduit concealed type all as specified and directed

80

-

-

... More
S&F 12W LED Surface Downlight having Luminous efficacy of 100, input voltage range 140-270 V, input frequency 50-60 Hz complete including connecting up with suitable size three core copper conductor cable all as specified and directed by the engineer-in-charge.

426

-

-

... More
S&F Next generation, energy saving, environment friendly & robust design high bay LED light fitting of 120W with PDC housing suitable for ceiling (Surface/Suspended) mounting with system efficacy up to 300 lm/W complete including connecting up with suitable size three core copper conductor cable all as specified by Engineer-in-charge.

25

-

-

... More
S&F flame proof weather proof (for installation in hazardous area as per IS-2148/ 81) LED Tube light fitting epoxy powder coated with provision of cable glands duly tested and certified by CMRI Dhanbad suitable for and including 20 Watt LED Tube made out of cast iron aluminium alloy LM-6 enclosure with clear heat resistant borosilicate glass tubing spring loaded non sparking bipin lamp holder built in control gear fitted with copper wound ballast condenser starter all accessories prewired including 02 Nos M-20 cable entries mounted on wall/ column steel structure complete all as specified and directed.

7

-

-

... More
S&F Flame Proof Exhaust Fan 305mm (12") sweep, 1440 RPM speed, 250 volts, single phase, 50 Hz AC supply totally enclosed heavy duty motor with die cast aluminium rotor mounted on 02 ball bearings along with louvers and connecting electrically with 3 Core 1.00 Sq.mm size PVC insulated FRLS flexible copper conductor cable overall sheathed drawn through flame proof flexible conduit all as required at site with connected accessories complete all as specified and as directed.

4

-

-

... More
M&L for Boring for Bored cast -in-situ piles 600mm dia in any strata except hard rock using DMC method (Direct mud circulation) and getting out and disposal of spoil to a place out side MD land complete all as specified and as directed.

15200

-

-

... More
M&L for Boring for Bored cast -in-situ piles 750mm dia in any strata except hard rock using DMC method (Direct mud circulation) and getting out and disposal of spoil to a place out side MD land complete all as specified and as directed.

6000

-

-

... More
Boring for Bored cast in situ of piles of 600mm dia, depth as per drg in any type of soil including silty sand/ soft rock (but except in hard rock) and getting out and disposal of spoil to outside MD land using DMC method (Direct mud circulation) all as specified and directed by Engineer- in - Charge

7392

-

-

... More
Boring for Bored cast in situ of piles of 450mm dia, depth as per drg in any type of soil including silty sand/ soft rock (but except in hard rock) and getting out and disposal of spoil to outside MD land using DMC method (Direct mud circulation) all as specified and directed by Engineer- in - Charge

15216

-

-

... More
Carrying out initial load testing on 600mm dia, 28m deep piles of following test all as per IS complete all as specified and as directed including necessary anchoring and support piles of suitable load/size to be casted as required:

-

-

-

... More
A) Compression test

1

-

-

... More
B) Pull out test

1

-

-

... More
C) Lateral test

1

-

-

... More
Carrying out initial load testing on 450mm dia, 9m deep piles of following test all as per IS complete all as specified and as directed including necessary anchoring and support piles of suitable load/size to be casted as required:

-

-

-

... More
A) Compression test

1

-

-

... More
B) Pull out test

1

-

-

... More
C) Lateral test

1

-

-

... More
Carrying out initial load testing on 450mm dia, 20m deep piles of following test all as per IS complete all as specified and as directed including necessary anchoring and support piles of suitable load/size to be casted as required:

-

-

-

... More
A) Compression test

1

-

-

... More
B) Pull out test

1

-

-

... More
C) Lateral test

1

-

-

... More
Carrying out initial load testing on 450mm dia, 10m deep piles of following test all as per IS complete all as specified and as directed including necessary anchoring and support piles of suitable load/size to be casted as required:

-

-

-

... More
A) Compression test

1

-

-

... More
B) Pull out test

1

-

-

... More
C) Lateral test

1

-

-

... More
Carrying out initial load testing on 450mm dia, 28m deep piles of following test all as per IS complete all as specified and as directed including necessary anchoring and support piles of suitable load/size to be casted as required:

-

-

-

... More
A) Compression test

1

-

-

... More
B) Pull out test

1

-

-

... More
C) Lateral test

1

-

-

... More
Carrying out routine load testing on 600mm dia, 28m deep piles of following test all as per IS complete all as specified and as directed:

-

-

-

... More
A) Compression test

5

-

-

... More
B) Pull out test

5

-

-

... More
C) Lateral test

5

-

-

... More
Carrying out routine load testing on 450mm dia, 9m deep piles of following test all as per IS complete all as specified and as directed:

-

-

-

... More
A) Compression test

12

-

-

... More
B) Pull out test

12

-

-

... More
C) Lateral test

12

-

-

... More
Carrying out routine load testing on 450mm dia, 20m deep piles of following test all as per IS complete all as specified and as directed:

-

-

-

... More
A) Compression test

1

-

-

... More
B) Pull out test

1

-

-

... More
C) Lateral test

1

-

-

... More
Carrying out routine load testing on 450mm dia, 10m deep piles of following test all as per IS complete all as specified and as directed:

-

-

-

... More
A) Compression test

15

-

-

... More
B) Pull out test

15

-

-

... More
C) Lateral test

15

-

-

... More
Carrying out routine load testing on 450mm dia, 28m deep piles of following test all as per IS complete all as specified and as directed:

-

-

-

... More
A) Compression test

1

-

-

... More
B) Pull out test

1

-

-

... More
C) Lateral test

1

-

-

... More
Carrying out pile integrity testing on following dia piles all as per IS complete all as specified and as directed:

-

-

-

... More
A) 600mm dia, 28m deep

261

-

-

... More
B) 450mm dia, 9m deep

607

-

-

... More
C) 450mm dia, 20m deep

34

-

-

... More
D) 450mm dia, 10m deep

736

-

-

... More
E) 450mm dia, 28m deep

54

-

-

... More
M&L for applying 05 layer Acrylic Coating (Synthetic Flooring) (one layer Acrylic resurfacer, two layer Acrylic cushion rubber, two layer colour coating & game line marking) on prepared premix asphaltic semi dense concrete surfaces, uniform smooth surface & seamless finish, excellent grip in all weather conditions, slip resistant balanced mix of cushioning and hardness including infilled rubber crumbs, resistance to antifungal, anti microbial, ultra violet condition and the application system should ensure there is no jerk & injury on players body extremely user's friendly and true bounced and accurate deviation of ball including necessary game line, marking complete for outdoor type volleyball and basket ball court complete all as specified and directed. (Make of the synthetic flooring : REBOUND ACE, or equivalent. (Note : The application of synthetic flooring shall be carried out by manufacturer's authorized applicator as approved by GE)

540

-

-

... More
Package type Sewage treatment plant STP of 15 KLD Capacity: Designing (hydraulically, structurally & aesthetically), supplying, hydraulic testing, commissioning and giving satisfactory trials of 15 KLD Package type STP consisting of Fine bar Screen chamber with steel screen, Oil & Grease Remover, Grit separator, Equalization Tank, Air Grid for Equalization Tanks, Feed Pumps (2 No), Moving Bed Bio Reactor(s) with plastic media (of appropriate density, size and quantity to keep very high MLSS 15,000 mg/lit), Air Blowers for MBBR, Tube Settler assembly, Sludge Drying Bed of appropriate size, Chlorine Dozing System, Chlorine contact tank, Foundation for all E/M equipments, Associated piping work with required valves, gates, drains, pathways, Electrical control Panel with interconnecting cable, spare parts for 2 years of operation, etc. complete as turnkey job with all involved civil, electrical, digital and mechanical works as per detailed specifications for civil, electrical and mechanical components complete. For tertiary treatment, it also includes Filter Feed Tank of RCC, Filter Feed Pumps, Dual Media Filter, Activated Carbon Filter, Treated water Tank in RCC. Treated sewage can be used for irrigation, horticulture, fire fighting and MT wash complete all as specified and directed.

1

-

-

... More
Supply, installation & commissioning of 1 HP Non clog vertical submersible pumps with chrome steel impeller and cutter, non-clog to pass 40 mm size particles including Supply, installation with guide rail and lifting chain, cables, Earthing, testing complete with 2 years maintenance complete all as specified and directed. Flow and head -lpm x mtr - 50 x 25. (1 No working and 01 standby)

2

-

-

... More
S&F DOL starter suitable for 1 HP submersible pump complete all as directed

2

-

-

... More
Supplying, installing, testing & commissioning of Silent engine generating set of capacity 58.5 kVA with acoustic enclosure as per new CPCB-IV+ norms of emission control, 415 volts, 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including acoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613 /5000 with suitable AMF Panel as per manufacturer's recommendations complete all as specified and directed with the following :- (A) Alternator :- Standard design alternator rated at 58.5 kVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 phase, 4 wire, 415 volts, 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722. The Alternator shall be:- (i) Insulation class - 'H‘ (ii) Temperature rise Class - 'H‘ (iii) Excitation : Self Excited (iv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% (v) Frequency regulation +/- 1%.

1

-

-

... More
(B) Diesel Engine: - Adequate capacity of Diesel engine on manufacturers technical details air/ water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under :- i) Fly wheel with housing ii) Cooling system :- Moulded radiator with fan & belts iii) Cooling Water pump : - Centrifugal type belt driven iv) Exhaust System :-As per OEM Tech Specs. Exhaust gas turbo charger type. Exhaust manifold Silencer : Residual type Bellows v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. vi) Lub oil System :(a) Lubricating oil filter (b) Lubricating oil pump vii) Air Intake System : (a) Air intake Manifold - Air cleaner dry type viii) Governor :- Electronic Governor ix) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator

-

-

-

... More
x) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant, Paper element filters for fuel, lub oil and by pass, Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel xi) Coupling arrangement: - Flexible coupling, fly wheel to suit flexible coupling xii) Accessories :- AVM Pads built in enclosure and for entire unit on platform. xiii) Base Frame : - Should be provided as OEM norms xiv) Fuel Tank :- As per OEM tech Spec.

-

-

-

... More
(C) GENERATOR CONTROL PANEL :- The standard microprocessor based control panel shall be fabricated made out of CRCA sheet and powder coated in side and out side and shall display as follows:- (i) Voltage of all Three phases, (ii) Current of all Three phases, (iii) Frequency, (iv) Bus bar Chamber with aluminum bus bar of cap 500 Amps - 04 Nos, (v) C.T. 100/5 Amps - 03 Nos. (vi) MCCB TPN, of appropriate capacity - 01 No and the digital panel should display Engine temperature, Coolant Temperature, Hour run, Oil pressure, RPM, Battery Volt etc as per standard. (D) Acoustic Enclosure:- Manufactured by OEM suitable for 58.5 KVA DG Set (i) NAL approved as per CPCB-IV+ (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board (iii) The generating set batteries and control panel should be inside the enclosure. (iv) Fuel tank should be integral part and inside the enclosure. (v) Construction Details/specification are as follows: a) Outer body :- As per OEM Tech Spec b) Doors :- As per OEM Tech Spec c) Sound Insulation :- As per OEM Norms vi) The acoustic enclosure should be composite in construction and fully assembled integral unit (vii) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated platform viii) The DG Set should be provided with external Emergency stop push button. ix) The enclosure should be suitably illuminated by LED Lamp fittings. x) The noise level should be 75 dba at 1m under free field conditions. xi) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade. Note : Foundation should be provided as per OEM recommendation and 300 mm platform beyond all side of DG set and the cost for the same is inclusive in quoted rate.

-

-

-

... More
Disconnecting and shifting of existing 100 KVA DG set from its installed location to new location including provision of necessary PCC foundation, cable connections, carrying out 'B' check and attending to any minor repairs/ replacement of parts etc, re-commissioning complete all as directed.

1

-

-

... More
S&F Hot dip Galvanized Octagonal street light Poles of 7.0 meter long, Top dia 70mm , bottom dia 130mm and sheet thickness 3mm including top bracket for light fitting complete with base frame plate, foundation bolt, nut and washers, top etc. Window- Plasma cut and duly chamfered opening window of 300 x 110 mm for terminal connection and mounting accessories with suitable capacity MCBs. Window cover is fitted with allen screws to the pole complete all as specified and directed by Engr-in-charge.

79

-

-

... More
S&F Inverted Pyramid Tripod type LED Bollard with soft 360° light fitting, 10 Watt 230 V AC outdoor type including thermal management in multiple optics with IP 65/66 protection complete.

40

-

-

... More
Supply, installation, testing and commissioning floor mounted outdoor LT panel with canopy of suitable size wit IP 54 protection. The Panel made out of 3 mm thick MS CRCA sheet dust and vermin proof with angle iron structure 40x40x6 mm, CPRI approved, compartmental type of size as required including locking arrangement and powder coated over a coat of red oxide metal primer, fixed in floor with MS angle iron 40x40x6mm frame structure and grouted with PCC M-15 (Nominal mix) using 20mm graded stone aggregate with and including 50 Amps copper bus bar for phases and neutral with porcelain insulator complete with all fittings and fixing arrangement with suitable size FRLSH copper wired connection, cable glands for cable entry etc complete all as specified and as directed with the following accessories:

2

-

-

... More
INCOMER (i) 4 Pole MCCB 16 Amps, 16 KA Breaking Capacity with thermal magnetic release- 01 No OUTGOING (i) 6 Amps MCB 4 Pole - 03 Nos (ii) Digital type Ammeter , range 0 to 400 Amp with and CT -01 Nos (iii) Digital type Volt meter, range 0 to 500 Volt - 01 Nos (iv) MCB SPN - 6-32 A -02 Nos (v) Digital Time switch with contactor - 03 No (vi) LED indicator Light - 01 set (3 Nos) Note: Quoted rate is inclusive of necessary PCC foundation and earth work.

-

-

-

... More
Supply and fixing Integral LED aviation light 12 W comprising of aluminium housing with polycarbonate enclosure with connection by flexible wire nearest to available electric connection complete all as specified and as directed.

2

-

-

... More
Supply, Design, install, testing and commissioning of Roof top solar generation of 62 KWp AC capacity all as specified hereinafter:-

1

-

-

... More
(A) Supply, installation, testing and commissioning of 540/545/535 Wp solar photo voltaic modules/array of high efficiency made of mono crystalline silicon solar PV cells with s&f of terminal box on the module should have provision for opening & replacing the cable etc. as per direction of E.I.C. The general features of PV modules as given below :- a) The module shall be made up mono crystalline silicon cells. b)The interconnected cells shall be laminated in vacuum to withstand adverse environmental conditions. c) The module frame is made of corrosion resistant materials, preferably having aluminium anodized finish. d) The minimum clearance between the lower edge of the modules & the developed ground level shall be 500 mm. e) Surge arresting device to be provide at junction box and module shall be provided bypass diode. f) The SPV module must be IEC 61215, IEC 61730 part I & part II, IEC 61701 certified from any of the accredited certifying agencies. g) Each solar PV module must be warranted by manufacturer at least 80% rated power. Note : Design and qty decided as per OEM recommendation, design and layout drawing shall be submitted to Department for approval of Accepting Officer).

-

-

-

... More
(B) Module Mounting Structure (MMS) Supply & fixing of the anti-corrosive factory made GI structure on the ground, fixing of PV modules by fixing of suitable size fasteners, spring washer, nuts & bolt. The minimum thickness of galvanization in such a way shall withstand the wind load of 180 Km/hr as per IS 875. The array structure shall be grounded properly using maintenance free earthing kit suitable for mounting & RCC foundation shall be minimum M20 Grade. Note : Design and qty of MMS shall be decided as per OEM design, above said quantity may vary as per design and layout, If any variation in quantity is inclusive of the quoted rate. Design and drawing shall be submitted to Department for approval of Accepting Officer.

-

-

-

... More
(C) On Grid Power Conditioning Unit (Inverter) (Qty-01 No) Supply & installation of 415V 3-ph grid connected Inverter which converts DC energy produced by the solar array to AC energy such that it synchronizes with the existing AC power sources on site and also install power manager to get all parameter details. The Inverter shall have inbuilt MPPT (Maximum Power Point Tracker) feature so as to extract maximum power from PV modules & the MPPT units environmental testing shall qualify IEC 60068-2 (1,2,14,30)/ Equivalent BIS standard. (The voltage variation of +/- 15% to 20% & frequency variation +/- 5%)

-

-

-

... More
(D) AC Distribution Board (i) Supply & installation of 415V 3-ph 50Hz AC distribution board control AC power from PCU/ Inverter & provided by necessary surge arrestors system and energy meter (KWH) with IP65 protection and suitable capacity MCCBs.; Qty- 01 No Note : ACDB shall be covered as per OEM design in such a way that structure must sustain 180 km/hr wind speed.

-

-

-

... More
(ii) Distribution wiring in 1.1kv single core stranded FR PVC insulated & unsheathed copper wire 35 sq.mm sion) on wall :- (For AC power supply from Inverter to AC distribution board to Panel);

-

-

-

... More
(E) AC distribution board to panel :- (i) Supply & laying of 1 core 4 sq.mm. copper cable in PVC rigid conduit pipe by saddling as per direction of E.I.C. (For Solar Array DC supply connection); Note : Cable should be passes through PVC rigid pipe and pipe should be fixed properly inside cable tray for easily maintenance, is included in quoted rate.

-

-

-

... More
(G) Misc items (i) Making soldered joints between conductors, conductors and air terminals for 4 SWG GI (Hot Dip) wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint;

-

-

-

... More
(ii) UPVC Conduit Pipes 3/4" with Tee, Elbow, Bendovers, Sockets for DC Cabling,

-

-

-

... More
(iii) UPVC Conduit Pipes 1" with Tee, Elbow, Bendovers, Sockets for DC Cabling,

-

-

-

... More
(iv) UPVC Conduit Pipes 1" with Tee, Elbow, Sockets, Ball Valves for Manual Module Cleaning System,

-

-

-

... More
(v) Supply & fixing GI (Hot Dip) strips 25 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works (Galvanised above 75 microns)

-

-

-

... More
(vi) Supply & fixing of GI (Hot Dip) strips 25 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000mm apart incl. mending good damages to building work (Galvanised above 75 microns)

-

-

-

... More
(vii) Earthing with 2 Mts. long Copper bonded Rod galvanized above 250 microns with bolts, double nuts, double washers incl. S & F 15 mm dia GI Strip protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 2.5 Mts. below the ground level - Chemical Earthing as per standard; Qty- 4 sets

-

-

-

... More
(viii) Lightening arrestor Conventional type Copper Galvanized above 200 microns

-

-

-

... More
(ix) Remote Monitoring System-with i-TAP Adaptor box for supply Ver 2.1 Note: Sim card with data back for remote monitoring of system deemed inclusive of the rate.

-

-

-

... More
(H) WARRANTY : (i) The warranty for complete system shall be for 05 years from the date of installation.

-

-

-

... More
(i) PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less 80% at the end of 25 years & not less than 90% at the end of 10 years.

-

-

-

... More
(J) DEFECT LIABILITY AND COMPREHENSIVE MAINTENANCE

-

-

-

... More
(i) The contractor shall have 5 year Defect Liability period from the certified date of completion of Phase-II. Condition 46 of IAFW-2249 shall be deemed to be amended to this effect. During the DLP contractor shall ensure generation of Minimum Average units (4 Units/KW/Day). Contractor rep and GE rep will make a joint inspection of plant on monthly basis and monthly summary of plant production will be jointly signed.

-

-

-

... More
(ii) The comprehensive maintenance of the solar power plant for 5 years during defect liability period is deemed be included in scope and contractor to quote accordingly. All required spares and periodical checking is deemed to be included.

-

-

-

... More
Note: The quoted rate deemed inclusive of the following:- (i) Transportation charges with transportation insurance for all the material of on grid solar system including loading & unloading at site from Company's workshop. (ii) Insurance for the complete system for the 1st Year (iii) AMC- Suraksha which include 12 site Maintenance visits, Response time 2 hrs and turnaround time 48 hrs, (iv) Monthly plant performance report. (v) Guarantee and warranty of Solar panel and connected devices shall be submitted to department. (vi) The report of generated unit of solar power on monthly basis submitted to department. (vii) Satisfactorily testing and commissioning report of the complete system shall be submitted to department.

-

-

-

... More
Supply, Design, install, testing and commissioning of Roof top solar generation of 38 KWp AC capacity all as specified in PS clause and specification as follows :

1

-

-

... More
(A) Supply, installation, testing and commissioning of 540/545/535 Wp solar photo voltaic modules/array of high efficiency made of mono crystalline silicon solar PV cells with s&f of terminal box on the module should have provision for opening & replacing the cable etc. as per direction of E.I.C. The general features of PV modules as given below :- a) The module shall be made up mono crystalline silicon cells. b)The interconnected cells shall be laminated in vacuum to withstand adverse environmental conditions. c) The module frame is made of corrosion resistant materials, preferably having aluminium anodized finish. d) The minimum clearance between the lower edge of the modules & the developed ground level shall be 500 mm. e) Surge arresting device to be provide at junction box and module shall be provided bypass diode. f) The SPV module must be IEC 61215, IEC 61730 part I & part II, IEC 61701 certified from any of the accredited certifying agencies. g) Each solar PV module must be warranted by manufacturer at least 80% rated power. Note : Design and qty decided as per OEM recommendation, design and layout drawing shall be submitted to Department for approval of Accepting Officer).

-

-

-

... More
(B) Module Mounting Structure (MMS) Supply & fixing of the anti-corrosive factory made GI structure on the ground, fixing of PV modules by fixing of suitable size fasteners, spring washer, nuts & bolt. The minimum thickness of galvanization in such a way shall withstand the wind load of 180 Km/hr as per IS 875. The array structure shall be grounded properly using maintenance free earthing kit suitable for mounting & RCC foundation shall be minimum M20 Grade. Note : Design and qty of MMS shall be decided as per OEM design, above said quantity may vary as per design and layout, If any variation in quantity is inclusive of the quoted rate. Design and drawing shall be submitted to Department for approval of Accepting Officer.

-

-

-

... More
(C) On Grid Power Conditioning Unit (Inverter) (Qty-01 No) Supply & installation of 415V 3-ph grid connected Inverter which converts DC energy produced by the solar array to AC energy such that it synchronizes with the existing AC power sources on site and also install power manager to get all parameter details. The Inverter shall have inbuilt MPPT (Maximum Power Point Tracker) feature so as to extract maximum power from PV modules & the MPPT units environmental testing shall qualify IEC 60068-2 (1,2,14,30)/ Equivalent BIS standard. (The voltage variation of +/- 15% to 20% & frequency variation +/- 5%)

-

-

-

... More
(D) AC Distribution Board (i) Supply & installation of 415V 3-ph 50Hz AC distribution board control AC power from PCU/ Inverter & provided by necessary surge arrestors system and energy meter (KWH) with IP65 protection and suitable capacity MCCBs.; Qty- 01 No Note : ACDB shall be covered as per OEM design in such a way that structure must sustain 180 km/hr wind speed.

-

-

-

... More
(ii) Distribution wiring in 1.1kv single core stranded FR PVC insulated & unsheathed copper wire 35 sq.mm sion) on wall :- (For AC power supply from Inverter to AC distribution board to Panel);

-

-

-

... More
(E) AC distribution board to panel :- (i) Supply & laying of 1 core 4 sq.mm. copper cable in PVC rigid conduit pipe by saddling as per direction of E.I.C. (For Solar Array DC supply connection); Note : Cable should be passes through PVC rigid pipe and pipe should be fixed properly inside cable tray for easily maintenance, is included in quoted rate.

-

-

-

... More
(G) Misc items (i) Making soldered joints between conductors, conductors and air terminals for 4 SWG GI (Hot Dip) wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint;

-

-

-

... More
(ii) UPVC Conduit Pipes 3/4" with Tee, Elbow, Bendovers, Sockets for DC Cabling,

-

-

-

... More
(iii) UPVC Conduit Pipes 1" with Tee, Elbow, Bendovers, Sockets for DC Cabling,

-

-

-

... More
(iv) UPVC Conduit Pipes 1" with Tee, Elbow, Sockets, Ball Valves for Manual Module Cleaning System,

-

-

-

... More
(v) Supply & fixing GI (Hot Dip) strips 25 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works (Galvanised above 75 microns)

-

-

-

... More
(vi) Supply & fixing of GI (Hot Dip) strips 25 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000mm apart incl. mending good damages to building work (Galvanised above 75 microns)

-

-

-

... More
(vii) Earthing with 2 Mts. long Copper bonded Rod galvanized above 250 microns with bolts, double nuts, double washers incl. S & F 15 mm dia GI Strip protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 2.5 Mts. below the ground level - Chemical Earthing as per standard; Qty- 4 sets

-

-

-

... More
(viii) Lightening arrestor Conventional type Copper Galvanized above 200 microns

-

-

-

... More
(ix) Remote Monitoring System-with i-TAP Adaptor box for supply Ver 2.1 Note: Sim card with data back for remote monitoring of system deemed inclusive of the rate.

-

-

-

... More
(H) WARRANTY : (i) The warranty for complete system shall be for 05 years from the date of installation.

-

-

-

... More
(i) PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less 80% at the end of 25 years & not less than 90% at the end of 10 years.

-

-

-

... More
(J) DEFECT LIABILITY AND COMPREHENSIVE MAINTENANCE

-

-

-

... More
(i) The contractor shall have 5 year Defect Liability period from the certified date of completion of Phase-II. Condition 46 of IAFW-2249 shall be deemed to be amended to this effect. During the DLP contractor shall ensure generation of Minimum Average units (4 Units/KW/Day). Contractor rep and GE rep will make a joint inspection of plant on monthly basis and monthly summary of plant production will be jointly signed.

-

-

-

... More
(ii) The comprehensive maintenance of the solar power plant for 5 years during defect liability period is deemed be included in scope and contractor to quote accordingly. All required spares and periodical checking is deemed to be included.

-

-

-

... More
Note: The quoted rate deemed inclusive of the following:- (i) Transportation charges with transportation insurance for all the material of on grid solar system including loading & unloading at site from Company's workshop. (ii) Insurance for the complete system for the 1st Year (iii) AMC- Suraksha which include 12 site Maintenance visits, Response time 2 hrs and turnaround time 48 hrs, (iv) Monthly plant performance report. (v) Guarantee and warranty of Solar panel and connected devices shall be submitted to department. (vi) The report of generated unit of solar power on monthly basis submitted to department. (vii) Satisfactorily testing and commissioning report of the complete system shall be submitted to department.

-

-

-

... More
Supply, install, testing and commissioning of Reverse Osmosis Plant of 1000 LPH capacity comprising of multi-grade filter, activated carbon filter, anti-scaling dosing system, oxidization chamber, filter feed pump complete all as directed Note: The Design basis, scope of supply and technical specifications of the intended OEM shall be submitted by the contractor to the GE for approval before placing order.

1

-

-

... More
Supply, install, testing and commissioning of Reverse Osmosis Plant of 500 LPH capacity comprising of multi-grade filter, activated carbon filter, anti-scaling dosing system, oxidization chamber, filter feed pump complete all as directed Note: The Design basis, scope of supply and technical specifications of the intended OEM shall be submitted by the contractor to the GE for approval before placing order.

1

-

-

... More
Design, supply, install, testing and commissioning of electrically operated 13 passengers Lift (884 Kg) in the existing lift well, speed 1.5 metre/sec, lift with single speed motor (Gearless machine) of 415 volts, 3 phase, 50 Hz AC supply conforming to IS-14665, suitable to serve Stilt + 7 upper floors i.e. with 8 stops and 8 landings with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening sliding stainless steel door with moon rock finish of 16 gauge with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system with batteries, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door), complete all as specified and directed.

2

-

-

... More
(a) TECHNICAL SPECIFICATIONS (i) Type & Capacity: electrically operated Passenger elevator for 08 persons (884Kg). (ii) Type of drive: Variable voltage and variable frequency drive with microprocessor based controller + 5 mm landing accuracy with speed encoder. (iii) Speed: 1.5 meter per second. (iv) Travel: Suitable for passenger travel to serve G+9, (opening on same side). (v) Existing well size: 2600 mm x 2000 mm deep (over plaster) (approx) without any projected beam/column. (vi) Power supply: 03 Phase, 415 V, 50Hz (should withstand variation of + 5%). (vii) Inner size: 2000mm x 1100mm deep (Approx). (viii) Car enclosure: Stainless steel panel body of 16 gauge with moon rock finish, Car frame floor integrity to be ensured. SS false ceiling (hairline finish) and stainless steel handrail of standard dia and size with hair line finish and splinter proof mirror of 4mm thickness in front half of the lift car.

-

-

-

... More
(ix) Flooring: Polished granite flooring. (x) Electric light: LED Light fitting (Min 04 Nos). (xi) Fan: Fresh Air fan 380mm sweep – 01 No. (xii) Car entrance: Automatic, centre opening, sliding doors. (xiii) Clear opening: Not less than 900mm x 2000mm high. (xiv) Operation door: Automatic operation with stainless steel frame front opening landing door of toughened glass not less than 12 mm thick. (xv) Control: Simplex full collective with and without attendant. (xvi) Indicators: Hall position indicators for car & landing direction and position indicator with stainless steel fixtures at all floors. (xvii) Main drive and control shall be latest, high efficient and low power consumption.

-

-

-

... More
(b) STANDARD FEATURES (i) Anti nuisance car call protection. (ii) Automatic car return device (home landing). (iii) Independent service (for duplex only). (iv) Overloading device with tripping system including warning indicator both audio and visual types. (v) Nudging buzzer if door is held open for more than 30 sec.. (vi) Emergency fireman’s service. (vii) Audible car call button. (viii) Emergency car light unit. (ix) High performance contact free infrared curtain door protection. (x) Door time adjustable from (0-30 Sec). (xi) Emergency alarm button. (xii) Extra door time of lobby & parking. (xiii) Door open close button. (xiv) Manual rescue operation. (xv) Belt inspection device. (xvi) Suitable phase reverse relay shall be provided to the controller to protect lift against phase reversal, phase failure and low voltage. (xvii) Set of three limit switches at the bottom and top most position of lift hoist ways as specified in IS. (xviii) Indoor communication to be connected with nearest security post.

-

-

-

... More
(c) ADDITIONAL FEATURES (i) Automatic rescue device.: During power failure and manual operation suitable provision shall be provided to run the lift with full load to the nearest floor (ii) Floor announcement system: Each floor shall be provided with announcement system.

-

-

-

... More
(D) HUMAN INTERFACE DEVICE (HID) (i) Hall button with micro stroke push buttons combined with 16-segment digital LED display position indicator. (ii) Full height car operating panel with micro stroke call push buttons (located on side panel) . (iii) Door open/Door closed on car operating panel. (iv) 2-way intercommunication system. (v) Monochrome LED digital position indicator display. (vi) Battery operated alarm bell & emergency light. (vii) Fireman’s switch at main lobby. (viii) Manual rescue operation. (ix) Call register indicator in all landings. (x) Attendant operation system in car panel.

-

-

-

... More
Design, supply, install, testing and commissioning of electrically operated 13 passengers Lift (884 Kg) in the existing lift well, speed 1.5 metre/sec, lift with single speed motor (Gearless machine) of 415 volts, 3 phase, 50 Hz AC supply conforming to IS-14665, suitable to serve Stilt + 4 upper floors i.e. with 5 stops and 5 landings with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening sliding stainless steel door with moon rock finish of 16 gauge with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system with batteries, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door), complete all as specified and directed.

1

-

-

... More
(a) TECHNICAL SPECIFICATIONS (i) Type & Capacity: electrically operated Passenger elevator for 08 persons (884Kg). (ii) Type of drive: Variable voltage and variable frequency drive with microprocessor based controller + 5 mm landing accuracy with speed encoder. (iii) Speed: 1.5 meter per second. (iv) Travel: Suitable for passenger travel to serve G+9, (opening on same side). (v) Existing well size: 2800 mm x 1900 mm deep (over plaster) (approx) without any projected beam/column. (vi) Power supply: 03 Phase, 415 V, 50Hz (should withstand variation of + 5%). (vii) Inner size: 2000mm x 1100mm deep (Approx). (viii) Car enclosure: Stainless steel panel body of 16 gauge with moon rock finish, Car frame floor integrity to be ensured. SS false ceiling (hairline finish) and stainless steel handrail of standard dia and size with hair line finish and splinter proof mirror of 4mm thickness in front half of the lift car.

-

-

-

... More
(ix) Flooring: Polished granite flooring. (x) Electric light: LED Light fitting (Min 04 Nos). (xi) Fan: Fresh Air fan 380mm sweep – 01 No. (xii) Car entrance: Automatic, centre opening, sliding doors. (xiii) Clear opening: Not less than 900mm x 2000mm high. (xiv) Operation door: Automatic operation with stainless steel frame front opening landing door of toughened glass not less than 12 mm thick. (xv) Control: Simplex full collective with and without attendant. (xvi) Indicators: Hall position indicators for car & landing direction and position indicator with stainless steel fixtures at all floors. (xvii) Main drive and control shall be latest, high efficient and low power consumption.

-

-

-

... More
(b) STANDARD FEATURES (i) Anti nuisance car call protection. (ii) Automatic car return device (home landing). (iii) Independent service (for duplex only). (iv) Overloading device with tripping system including warning indicator both audio and visual types. (v) Nudging buzzer if door is held open for more than 30 sec.. (vi) Emergency fireman’s service. (vii) Audible car call button. (viii) Emergency car light unit. (ix) High performance contact free infrared curtain door protection. (x) Door time adjustable from (0-30 Sec). (xi) Emergency alarm button. (xii) Extra door time of lobby & parking. (xiii) Door open close button. (xiv) Manual rescue operation. (xv) Belt inspection device. (xvi) Suitable phase reverse relay shall be provided to the controller to protect lift against phase reversal, phase failure and low voltage. (xvii) Set of three limit switches at the bottom and top most position of lift hoist ways as specified in IS. (xviii) Indoor communication to be connected with nearest security post.

-

-

-

... More
(c) ADDITIONAL FEATURES (i) Automatic rescue device.: During power failure and manual operation suitable provision shall be provided to run the lift with full load to the nearest floor (ii) Floor announcement system: Each floor shall be provided with announcement system.

-

-

-

... More
(D) HUMAN INTERFACE DEVICE (HID) (i) Hall button with micro stroke push buttons combined with 16-segment digital LED display position indicator. (ii) Full height car operating panel with micro stroke call push buttons (located on side panel) . (iii) Door open/Door closed on car operating panel. (iv) 2-way intercommunication system. (v) Monochrome LED digital position indicator display. (vi) Battery operated alarm bell & emergency light. (vii) Fireman’s switch at main lobby. (viii) Manual rescue operation. (ix) Call register indicator in all landings. (x) Attendant operation system in car panel.

-

-

-

... More
All as per Item No. 66 herein before but for 08 Passengers (544Kg)

1

-

-

... More
Supply, installation, testing and commissioning of VRF / VRV outdoor units, having R410A / R -407C refrigerant, multiple Nos. of inverter, digital scroll compressors, air cooled condenser fan with motor, microprocessor control panel, starter controls for all scroll compressors and condenser fan motors along with internal control and power wiring, cooling coil with internally interconnected refrigerant pipes for interconnecting various capacity modules, charging port and all other required accessories, & hardware, first charge of refrigerant and all other required accessories, hardware like T joints etc., all enclosed in an enclosure with weather resistant powder coating paint for withstanding all ambient conditions for continuous outdoor operation, suitable to operate on 3-Phase, 380-415 V, 50 Hz AC power supply complete all as specified and directed by the engineer-in-charge.

-

-

-

... More
The VRF/ VRV system shall be provided with mounting base and anti-vibration pad(s). All the accessories, hardware, software, consumables etc. whether specifically mentioned or not but required to put the VRF / VRV System into service up to the satisfaction of the Engineer-in-charge including testing, commissioning as per specifications, site constraints shall be deemed included in the scope of the work.

-

-

-

... More
Nothing extra shall be payable for these systems under any circumstances. All the consumables including first charge of refrigerant (R-410A / R - 407C) and oil for the proposed VRF / VRV system shall be deemed inclusive in the scope of work. The topping of refrigerant and oil shall also be included in the scope of work for arresting leakages if any. The unit shall be lifted using crane / sufficient manpower and installed on suitable pedestal / MS rail / bots & nuts etc, all complete as requirement of site conditions.

-

-

-

... More
VRF / VRV outdoor units of minimum 22 HP combined cooling capacity at site conditions

1

-

-

... More
VRF / VRV outdoor units of minimum 38 HP combined cooling capacity at site conditions

1

-

-

... More
VRF / VRV outdoor units of minimum 48 HP combined cooling capacity at site conditions

1

-

-

... More
Supply, installation, testing and commissioning of indoor units of following capacity suitable for mounting inside false ceiling / on wall, each comprising of cooling coil, blower with multi speed motor, electronic expansion valve, supply & return air grilles, filter, insulated connection of refrigerant circuit, provision for fresh air intake ducting, condensate water drain pump with electronic level sensor, including wireless remote controller etc. with all required supports, anchor fasteners hardware, etc. interconnecting refrigerant copper piping, support etc. including power cabling with 3 pin plug top in flexible conduit from units to the nearest plug point, control wiring of copper cables and interlocking with outdoor units complete all as specified and directed by the engineer-in-charge.

-

-

-

... More
HI-WALL TYPE WALL MOUNTED UNIT

-

-

-

... More
Supply, installation, testing & commissioning of Wall mounted Hi-wall type indoor unit with cordless remote controller of 1.3 TR Cooling Capacity & 417 ft3/min air-flow rate complete all as specified and directed by engineer-in-charge.

2

-

-

... More
Supply, installation, testing & commissioning of Wall mounted Hi-wall type indoor unit with cordless remote controller of 1.7 TR Cooling Capacity & 586 ft3/min air-flow rate complete all as specified and directed by engineer-in-charge.

2

-

-

... More
Supply, installation, testing & commissioning of Wall mounted Hi-wall type indoor unit with cordless remote controller of 2.5 TR Cooling Capacity & 875 ft3/min air-flow rate complete all as specified and directed by engineer-in-charge.

4

-

-

... More
Supply, installation, testing & commissioning of Wall mounted Hi-wall type indoor unit with cordless remote controller of 2.8 TR Cooling Capacity & 945 ft3/min air-flow rate complete all as specified and directed by engineer-in-charge.

7

-

-

... More
CEILING MOUNTED 3' x 3' LARGE CASSETTE UNIT

-

-

-

... More
Supply, installation, testing & commissioning of ceiling suspended cassette type indoor unit having 4-way / rounded uniform air-flow with cordless remote controller of 1.7 TR Cooling Capacity & 650 ft3/min air-flow rate complete all as specified and directed by engineer-in-charge.

2

-

-

... More
Supply, installation, testing & commissioning of ceiling suspended cassette type indoor unit having 4-way / rounded uniform air-flow with cordless remote controller of 2 TR Cooling Capacity & 695 ft3/min air-flow rate complete all as specified and directed by engineer-in-charge.

7

-

-

... More
Supply, installation, testing & commissioning of ceiling suspended cassette type indoor unit having 4-way / rounded uniform air-flow with cordless remote controller of 2.8 TR Cooling Capacity & 945 ft3/min air-flow rate complete all as specified and directed by engineer-in-charge.

5

-

-

... More
Supply, installation, testing & commissioning of ceiling suspended cassette type indoor unit having 4-way / rounded uniform air-flow with cordless remote controller of 3.2 TR Cooling Capacity & 1095 ft3/min air-flow rate complete all as specified and directed by engineer-in-charge.

7

-

-

... More
Ref-net Joints

-

-

-

... More
Supply, installation, testing and commissioning of variable refrigerant flow distribution ref-net (Y-joint) in the gas and liquid lines for indoor unit complete all as specified and directed by engineer-in-charge.

58

-

-

... More
Supply, installation, testing and commissioning of variable refrigerant flow distribution REFNUTS (Y-joint) in the gas and liquid lines for outdoor unit complete all as specified and directed by engineer-in-charge.

6

-

-

... More
Refrigerant copper piping

-

-

-

... More
Supply, installation, testing and commissioning of refrigerant copper piping (duly insulated with 19 mm thick closed cell elastomeric nitrile rubber tubular insulation) of hard drawn / soft drawn copper pipe, laid on walls / roof / ceiling well supported at specific intervals with metallic supports and screwed with anchor fasteners and necessary accessories, jointing / brazing etc., including connection between outdoor unit to indoor units as required complete all as specified and directed by the engineer-in-charge. NOTES: [i] The sizing of refrigerant copper piping shall be confirmed / vetted by the OEM. [ii] All piping inside the ceiling shall be properly supported using necessary clamps and all externals refrigerant lines shall be properly protected using necessary PVC (HDPE) pipes with accessories to suit the site conditions. [iii] The quantity of these items of works shall be measured as per actuals requirements of site conditions. The vendor shall accept the accepted rate as per the actual measured quantities.

-

-

-

... More
1/4" (6.4 mm)

40

-

-

... More
3/8" (9.5 mm)

210

-

-

... More
1/2" (12.7 mm)

70

-

-

... More
5/8" (15.9 mm)

150

-

-

... More
3/4" (19.1 mm)

50

-

-

... More
7/8" (22.2 mm)

40

-

-

... More
1- 1/8" (28.6 mm)

70

-

-

... More
1- 3/8" (34.9 mm)

10

-

-

... More
1- 5/8" (41.3 mm)

5

-

-

... More
M & L for following sizes UPVC drain water pipe including bends, collars & elbow etc, all complete and duly insulated with 9 mm thick tubular insulation of closed cell elastomeric nitrile rubber as required.

-

-

-

... More
20 mm

160

-

-

... More
40 mm

40

-

-

... More
Supply, installation, testing & balancing and commissioning of factory fabricated galvanized steel sheet metal (G.S.S.) 24 swg round / rectangular low pressure ducting of following sheet thickness having zinc coating of 120 g/m² total on both sides and complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, volume control dampers, hangers, supports, etc. as per approved drawings and conforming to IS 655: 2006 & the latest edition of HVAC Duct Construction Standards - Metal and Flexible of SMACNA along with required scaffolding work to install the ducts at site complete all as specified and directed by engineer-in-charge. NOTES: [i] The connection of ducts shall be carried out by angle flange technique. [ii] The quoted shall be inclusive of hangers & supports, etc.

270

-

-

... More
M&L for square / rectangular / round neck ceiling diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square / rectangular inlet being an integral part thereof, an inner core assembly consisting of fixed deflection louvers, heavy gauge steel volume control damper operable from the face of the diffuser by removing the spring-loaded inner core assembly, throw reducing vanes, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 170-1991 complete all as specified and directed by the engineer-in-charge.

-

-

-

... More
150 mm X 150 mm rectangular neck 4-way discharge ceiling diffuser having neck velocity ≤ 600 ft/min, throw ≥ 6' @ 150 ft/min velocity NC ≤ 18 for air flow ≥ 113 ft3/min

14

-

-

... More
225 mm X 225 mm rectangular neck 4-way discharge ceiling diffuser having neck velocity ≤ 600 ft/min, throw ≥ 8' @ 150 ft/min velocity NC ≤ 21 for air flow ≥ 260 ft3/min

6

-

-

... More
Treated Fresh Air Unit

-

-

-

... More
Supply, installation, testing and commissioning of floor mounted double skin treated fresh air unit (TFAU) having thermal break profile complete with airtight casing using gaskets and self-adhesive tapes, 0.8 mm thick pre-coated outer skin and 0.6 mm thick GI inner skin, 45±2 mm thick double skin panel with pressure injected CFC/HCFC free PUF having 'k' value ≤ 0.035 W/°C/m & density ≥ 40 kg/m³, G4 (EU4) grade pre-filter having 90% arrestance, DX cooling coil section with aluminium fins and copper tubes tested on 21 kg/cm², with SS sandwiched drain tray, etc., dynamically balanced DIDW backward curved fan along with IE3 motor complete with necessary piping, valves, etc. complete all as specified and directed by the engineer-in-charge

-

-

-

... More
400 CFM, 50 mm WC

1

-

-

... More
1000 CFM, 50 mm WC

2

-

-

... More
THERMAL INSULATION

-

-

-

... More
S&F of 19 mm black flexible closed-cell elastomeric thermal insulation made of elastomeric foam based on synthetic rubber (NBR / PVC), tested for maximum service temperature 100° C as per ASTM C534 & minimum service temperature -50° C as per ASTM C534, thermal conductivity λ ≤ 0.037 W/mK at mean temperature θm = 24° C as per ASTM C518 / C177, ASTM C335, water absorption by volume ≤ 0.2% as per ASTM C 209 / C1763, flame spread index (FSI) & smoke development index (SDI) 25/50 as per ASTM E84, flammability HB, V-0 as per UL 94, fungi resistance as per ASTM G21/C1338, mould growth resistance as per ASTM E2180-18 / UL 181 and ozone resistance as per ASTM D 1149-18 along with self pre-covered self-adhering, UV treated glass cloth of thickness 7 mm / 200 GSM adhesives and other necessary accessories complete all as specified and directed by the engineer-in-charge.

270

-

-

... More
Supply and install hi-wall split units indoor/ outdoor of capacity 2.0 TR complete with cordless remote control unit and with built-in air ionizer and Plasma filter for better indoor air quality. Notes: [i] The unit shall be suitable for 3- Phase, 415 V ± 10%, 50 Hz AC electric supply, with a built-in microprocessor based control panel. [ii] Initial / first charge of refrigerant gas & compressor shall be deemed included in the quoted rate. [iii] Refrigerant copper piping, fittings, insulation, supporting with necessary accessories shall be deemed included in the scope of work.

9

-

-

... More
M&L for telephone cables with high density polyethylene insulated, solid annealed high conductivity bare copper with dia 0.5mm, paired, polyester taped and sheathed with high oxygen index fire retardant PVC compound, generally conforming to ITD specifications G/WIR-06/02 May 94 of 1- Pair drawn through PVC conduit and connecting and testing complete. Note: PVC conduit shall be measured and paid separately

2500

-

-

... More
M&L for TV Co-axial cable of RG59 Electrolytic Grade solid annealed Copper conductor, Jelly filled, Aluminium foiled and Aluminium wire Braided drawn through PVC conduit and connecting and testing complete. Note: PVC conduit shall be measured and paid separately

500

-

-

... More
Supply & fixing telephone Jack RJ-11 1 module for Telephone and intercom connection

190

-

-

... More
Supply & fixing modular television socket 1 module for TV connection

17

-

-

... More
S&F Bullet Camera (2 MP) (Indoor IP Camera) with accessories. Key features - 1/2.8" progressive scan CMOSBLC/3D DNR/HLC 1920 × 1080@30fps Up to 40 m IR range 2.8 mm/4 mm/6mm fixed lens IP 67, 2 Behavior analyses, three streams, up to 40 MR IP range

127

-

-

... More
S&F Bullet Camera (5 MP, 4MM) (Out door IP Camera) with accessories. Key features - 1/2.7" Progressive Scan CMOS 2560 × 1920 @15fps, Color: 0.01 Lux @ (F1.2; AGC ON), 0.028 Lux @(F2.0; AGC ON) 2.8/4/6 mm fixed lens H.265+, H.265, H.264+, H.264, BLC/3D DNR/ROI/HLC, IP67, IK10, 2 Behavior analysis, up to 40 MR IP range

32

-

-

... More
S&F Network Video Recorder – 32 Channel, Key Features: H.265+/H.265/H.264+/ H.264 video formats, Up to 32-ch IP camera inputs, Up to 1-ch@32 MP/2-ch@12 MP/16-ch@1080p decoding capacity Up to 256/320 Mbps incoming bandwidth HDD hot swapping with RAID 0/1/5/6/10

5

-

-

... More
S&F Surveillance HDD - 10 TB HDD

40

-

-

... More
S&F Wall Cabinet 4 U

5

-

-

... More
S&F Wall Cabinet 2 U

14

-

-

... More
S& F 32" Monitor LCD Display with wireless mouse and color printer

5

-

-

... More
S&F PoE switch (Gigabit) - 16 Port

14

-

-

... More
S&F PoE switch (Gigabit) - 08 Port

1

-

-

... More
S&F Gigabit Ethernet Switch

5

-

-

... More
S&F HDME Cable

50

-

-

... More
S&F Cat 6 UTP Cable

2000

-

-

... More
S&F Electric Cable 1 sq.mm

150

-

-

... More
Installation, commissioning and Testing of CCTV System

1

-

-

... More
Supply, installation, testing and commissioning of FM approved and UL listed Network Control Display (NCD) capable of full supervision of all inputs and network integrity, having10" high definition 1024 X 600 colour touch screen display, environmental adjustment controls to maximize LCD legibility, LED status indicators (for power supply and off normal condition), network connection, three USB connections, trouble relay, tamper and trouble inputs, etc. and features viz. network-wide acknowledge silence, reset, lamp test, fully programmable node-mapping subsystem, colour coded icon based event notification, event vectoring, etc. along with UL listed non-resettable 24 VDC power source complete all as specified and directed by the engineer-in-charge.

1

-

-

... More
Supply, installation, testing and commissioning of FM approved & UL listed remote power supply conforming to UL 864 & 1481 and NFPA 72 with integral battery charger capable of charging up to 18 Ah batteries to provide regulated and filtered 24 VDC power to notification appliance circuits, having power-supervision relay, fully regulated and filtered power output, AC trouble report selectable for immediate 2-hour delay, selectable earth fault detection, etc. complete all as specified and directed by engineer-in-charge.

2

-

-

... More
Supply, installation, testing and commissioning of UL listed (fire fighter's) addressable Telephone Jack mounted to a single-gang electrical back box with suitable interface module for two way communication with the Central Fire Fighter Telephone Console complete all as specified and directed by engineer-in-charge.

13

-

-

... More
Supply, installation, testing and commissioning of UL listed Fire Fighter's Telephone Handset for two way communication with the Central Fire Fighter Telephone Console complete all as specified and directed by engineer-in-charge.

2

-

-

... More
M & L for low smoke zero halogen (LS0H) flame retardant fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V of the following sizes, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed by engineer-in-charge:

-

-

-

... More
2 core, 1.5 mm²

6380

-

-

... More
2 core, 2.5 mm²

260

-

-

... More
M & L for transparent FR PVC insulated, twin core copper conductor flexible industrial Speaker cable having stranded annealed tinned copper conductor, PVC insulated cores twisted to form pairs, shielded for interference rejection, unarmoured PVC sheathed 1.1 kV grade in conductor size 2 X 1.0 mm2 including laying, termination and ferruling complete all as specified and directed by engineer-in-charge.

1420

-

-

... More
Supply, installation, testing and commissioning of UL listed all purpose 2 W ceiling speaker having crush and rust resistant design and fully ABS plastic & ABS grille with tap-setting range between 1/4 W and 2 W, rated (RMS) voltage 70.7 V, sound pressure level at 1 W (1 m & 1 kHz) 80 ± 4 dB, frequency response 125 Hz- 16 kHz, (-10 dB with reference to 1 kHz), complete all as specified and directed by engineer-in-charge.

142

-

-

... More
Supply, installation, testing and commissioning of factory made, CPRI / ERDA type tested, fully compartmentalized bolted type Fire Emergency Panel (design verified assembly- DVA) of suitable size conforming to IEC 61439-1 & 2 and IEC 61641 and having modular extensible design suitable for indoor mounting, internal arc compliance of minimum 70 kA for 0.5 s, made out of 2.0 mm thick mild steel CRCA sheet, having both sides openable with hinged doors and locking arrangement, IP 43 & IK 10 protection, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3-Phase, 4-Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by the engineer-in-charge.

1

-

-

... More
The FEP shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper bus bar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] Circuit Breaker (a) 400 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2: 2016, having microprocessor based trip unit, adjustable overload setting, adjustable short-circuit setting, adjustable neutral protection, electrical interlocking, front indication LEDs, etc.- 01 Nos. [ii] Instrumentation & Measurement (a) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interrupts- 01 Nos. (b) 400/5A Cl. 1.0 C.T. with 15 VA burden- 01 Nos. (c) 6A, 10kA, 415V, 50 Hz 4P MCB- 01 Nos. [iii] Indication & Annunciation (a) LED phase indicators (Red, Yellow, Blue)- 01 Set (b) LED status indicators (ON, OFF, TRIP)- 01 Set

-

-

-

... More
[C] OUTGOING [i] Circuit Breaker (a) 320 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 3P MCCB, conforming to IEC 60947-2: 2016, having microprocessor based trip unit, adjustable overload setting, adjustable short-circuit setting, adjustable neutral protection, electrical interlocking, front indication LEDs, etc.- 02 Nos.(for Main Electric Pump) (b) 32 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 3P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 02 Nos.(for Jockey pump) (c) 32 A, 250 V, Ics = 100% Icu = 36 kA, 50 Hz 2P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 02 Nos. (for DE Controller)

-

-

-

... More
[ii] Motor Starter / Drive (a) Fully automatic digital soft starter suitable for 90 kW drive having adaptive acceleration control, built-in RTD & thermistor inputs, programmable auto start/stop, emergency run operation, fully programmable overload trip, etc. complete with contactors, push button, LED type indicators, auto/manual selector switch, current sensing type single phase preventer complete with all accessories and wiring etc.- 03 Nos. (b) Fully automatic DOL starter, suitable for 3.7 kW motor, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.- 03 Nos. [iii] Instrumentation & Measurement (a) 400/5A Cl 1.0 CT having 15VA burden- 02 Nos. (b) 40/5A Cl 1.0 CT having 5VA burden- 02 Nos. (c) 0-300A ammeter- 02 Nos. (d) 0-50A ammeter- 02 Nos. [iv] Indication & Annunciation (a) LED status indicators (ON, OFF, TRIP)- 12 Set

-

-

-

... More
NOTES: [i] The bus bars shall be of double deck arrangement for rating ≥ 2000A interleaved /non-interleaved design as per OEM. Separation of bus bar shall be as per Form 4b.F106 [ii] ACBs shall have separately powered, individual fault trip indication LEDs (For overload, short circuit, earth fault and trip-unit failure) shall be available on the trip unit which shall function even in the absence of external power supply to the breaker.ACB shall be suitable for ZSI. Trip units shall have thermal memory as standard. [iii] All the MCCBs up to 250 A shall be with thermal magnetic trip unit & above 250A shall be with microprocessor trip units. To ensure failsafe emergency tripping of the breakers (ACBs & MCCBs), it shall be supplied with continuous rated shunt trip coils. [iv] Necessary control and switching devices to execute the switching and control logic shall be deemed inclusive of the scope of supply irrespective of them being specified / not specified above or in the SLD. [v] The Panel / Switchboard shall be tested to withstand vibration caused by an earthquake in accordance with IEC 60068-3-3:2013 or IS 1893 Zone V.

-

-

-

... More
[vi] The Panel shall be purchased from the original equipment manufacturer (OEM) or OEM authorized franchises only. [vii] All the necessary noble components (viz., structural, Door noble like hinge, Bush, Door alignment gauge and Bus bar noble - Bus bar support, Close profile structure - horizontal & vertical) of the Panel shall be supplied by the OEM. [viii] The Contractor shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, typical GADs, etc. to the engineer-in-charge for approval of the MEP Consultant and thereafter A.O. / representative.

-

-

-

... More
M & L for low smoke zero halogen (LS0H) fire survival control cable with circuit integrity, conforming to BS 7846 and rated for 600 V, having plain annealed stranded copper conductor with fire-resistant mica tapes covered by an extruded layer of cross-linked polyethylene, extruded layer of thermoplastic low smoke zero halogen (LS0H) compound, single layer of galvanized steel wires and thermoplastic LS0H compound sheath, suitable for operating temperature range -40 ˚C to +90 ˚C and minimum bending radius being 12 times the overall cable diameter, including laying, clamping, termination and ferruling complete as specified and directed by the engineer-in-charge.

-

-

-

... More
2 core, 2.5 mm²

20

-

-

... More
3 core, 2.5 mm²

20

-

-

... More
12 core, 2.5 mm²

40

-

-

... More
M & L for 1.1 kV grade copper conductor, XLPE insulated unarmoured cable conforming to IS 7098 (Part 1): 1988, having stranded copper compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete all as specified and directed by engineer-in-charge.

-

-

-

... More
3 core 95 mm²

30

-

-

... More
3 core 6 mm²

60

-

-

... More
S & F of 100 mm X 50 mm X 1.6 mm (L X D X T) size of perforated painted with powder coating MS cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with MS suspenders including bolts, etc. complete all as specified and directed by the engineer-in-charge.

50

-

-

... More
M & L for PN 1.6 rated 200 mm NB polypropylene vortex inhibitor suction lift, conforming to BS 4504 with stainless wire mesh, bolts, nuts and washers, etc. complete all as specified and directed by the engineer-in-charge.

2

-

-

... More
S & F of PN 1.6 rated full bore, 25 mm NB two piece design, quarter turn, lever operated brass ball valve having nickel-plated forged brass body & end connector, brass chrome plated ball, PTFE body seat ring & packing, H.T. brass stem, nut & gland, rubber 'O' ring, powder coated MS lever and screwed female ends, etc. with accessories complete as specified and directed by the engineer-in-charge.

16

-

-

... More
M & L for FM approved and UL listed 25 mm NB compact 3 position ball valve with drain orifice (test and drain valve) to test and drain water flow through sprinkler systems having OFF-TEST-DRAIN position, integral sight glass, rated pressure 300 psi, orifice size 15 mm and K factor 5.6, conforming to NFPA 13, along with necessary accessories complete as specified and directed by the engineer-in-charge.

16

-

-

... More
S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as specified and directed by the engineer-in-charge.

22

-

-

... More
S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge.

26

-

-

... More
S & F of 4.5 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed by the engineer-in-charge.

26

-

-

... More
S & F Galvanized mild steel Fire bucket (Filled with dry sand) conforming to IS 2546: 1974 round bottom type enamel painted, white inside & Red out side and Letter "FIRE" in black out side and handle with mounting bracket complete as specified and directed by the engineer-in-charge.

5

-

-

... More
S & F of the following type of signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners as specified and directed by the engineer-in-charge:

-

-

-

... More
Sign of size 250 mm X 300 mm reading 'IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE' in 12.5 mm block letters in red and white background, properly spaced to provide good legibility located directly above the call-button and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level

28

-

-

... More
Sign of size 150 mm X 600 mm, posted and maintained within each stair enclosure on every floor, indicating the number of the floor in bold type and at 75 mm high numerals in red and white background, securely attached to the stair side of the door in a way that the bottom of the sign is not above 1.5 m from the finished floor level

28

-

-

... More
Sign of size 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the lift / lift bank / stairway by an alphabetical letter in bold type and at 75 mm high letters in red and white background, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level

13

-

-

... More
Material and labour for construction of valve chambers of size 600x600x1000 mm depth including excavation and earthwork. PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 150 mm thick & 150 mm wide offsets around over 100 mm thick hardcore, 200 mm thick PCC block masonry walls built in CM 1:4, 100 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/dense soil 6 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.

6

-

-

... More
Supply, installation, testing, and commissioning of Fully automatic DOL starter, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc. with complete all as specified and directed by the engineer-in-charge.

1

-

-

... More
M & L for PN 1.6 rated air vent valve having brass body, cover, adopter, disc assembly & cap, stainless steel strainer, plastic float and 25 mm screwed threaded ends suitable for maximum operating temperature 100 °C installed on all high points in the water piping system to automatically remove the trapped air with necessary accessories all complete as specified and directed by the engineer-in-charge.

2

-

-

... More
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity, having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour.

13

-

-

... More
Supply and fix refrigerator, electric driven (single phase), capacity 400 Litres .BEE 5 star rated.

1

-

-

... More
Supply and fix refrigerator, electric driven (single phase), capacity 165 Litres .BEE 5 star rated.

4

-

-

... More
Supply, installation, commissioning of Glass Top Deep Freezer single phase 240 volt, 50 Hz, 320 litre capacity having single door.

1

-

-

... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3.0 KVA complete.

14

-

-

... More
S&F speed breaker made of ABS material, two highly reflective reflectors moulded in PMMA material are welded with ABS through ultrasonic welding process and then fixed on the speed breaker of size 425x75x500mm. The whole breaker is fixed along with epoxy and hardener and bolts complete all as specified and as directed.

110

-

-

... More
Cutting 350 mm NB existing pipe and reducing to required length before laying in position for insertion of new tees, branches, etc. including bends, tapers, tee pieces (single & double branch) any type and angle/radius and straight connecting pieces but all flange end complete as specified and directed by the engineer-in-charge.

1

-

-

... More
Material and labour for construction of valve chambers of size 600x600x600 mm depth including excavation and earthwork. PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 150 mm thick & 150 mm wide offsets around over 100 mm thick hardcore, 200 mm thick PCC block masonry walls built in CM 1:4, 100 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/dense soil 6 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.

9

-

-

... More
Supply, installation, testing and commissioning of Monoblock, self-priming, single-stage centrifugal pump, capable of 8.80 LPS discharge at 20 MWC head, 7.5 HP pump having cast iron casing, enclosed type dynamically balanced cast iron impeller, carbon steel pump shaft, gland packed sealing, deep groove ball bearings, etc. with SPDP squirrel cage induction motor having class 'B' insulation, IE3 efficiency, conforming to IS 12615: 2018 and suitable for operation on 3-Ph, 415 V±10%, 50 Hz AC supply, base plate, mounting channel frame, accessories and fittings, viz. pressure gauges, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting along with accessories complete all as specified and directed by engineer-in-charge. (1 W + 1 S)

2

-

-

... More
The pump set shall include the following: [i] CI foot valve fixed with leather washer and NRV of suitable size life & swing single door IS-4030 marked. [ii] Vacuum gauge -01 no. [iii] Pressure gauge diaphragm type up to 50 kg/Cm 2 -01 no. [iv] Priming arrangement of pump set by providing GI pipe 20 mm dia medium grade, gate valve etc from near by existing line with all fittings etc complete - 1 Job [v] GI suction pipe medium grade more than 40 mm of suitable length but not less than 6 m & taper connection piece etc- 1 Job [vi] GI discharge pipe medium grade more than 40 mm of suitable length but not less than 6 m & taper connection piece etc- 1 Job NOTES: [i] Necessary civil work viz. foundation for placement of pump and accessories shall be covered in the scope of work.

-

-

-

... More
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type PUMP HOUSE PANEL of suitable size, having both sides openable with hinged double doors and locking arrangement, IP 43 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of 40 x 40 x 6 mm size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 3.15 mm thick mild steel vitreous enameled with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.

1

-

-

... More
The PUMP HOUSE PANEL shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper bus bar of rated capacity 160 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] 63 A, 25 kA, 415 V, 50 Hz, FP MCCB, conforming to IS/IEC 60947-2, with thermal magnetic release, rotary operating mechanism, electrical operating mechanism, mechanical interlock kit, spreader terminals, key lock, etc.- 01 Nos. [ii] Cl 1.0 multi-function meter (0-63 A range) capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interrupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set

-

-

-

... More
[C] OUTGOING [i] 32 A, 10 kA, 415 V, 50 Hz, TP MCB- 02 Nos. [ii] 32 A, 10 kA, 415 V, 50 Hz, FP MCB- 02 Nos. [iii] Fully automatic 5 HP DOL starter, suitable for the pumps, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.- 02 Nos. [iv] Cl 1.0 multi-function meter (0-63 A range) capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interrupts- 02 Nos. [v] LED phase indicators (Red, Yellow, Blue)- 04 Set NOTES: [i] The Panel shall be purchased as per Contract agreement [ii] The bidder shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, GADs, etc. for approval of the Engineer-in-Charge.

-

-

-

... More
Supply, install, testing & commissioning of indoor type 11 KV 3 phase, 350MVA, 50 HZ, 26.3 KA, 630 Amps HT totally enclosed free standing, sheet steel clad, cubical pattern, HT panel switch board with locking arrangement for panel doors, complete with short time with stand current sec with 3 Nos 800A PVC sleeved copper bus bars and comprising of the followings :- (4 VCB act as-01 Nos incomer and 3 outgoing and all VCB connected through bus coupler) complete all as per latest IS/IEC standards comprising of the following:-

1

-

-

... More
VCBs :- (A) Incoming TP vacuum circuit breaker 11 KV 630 A, horizontal draw out type, horizontal isolation, rated current 630 A -01 Nos each fitted with :- (a) Manually changing & closing mechanism, 1- Motorized spring charged closing mechanism. (i) Mechanical close/strip knob - 01 set (ii) Mechanical ON/OFF indicator - 01 No (iii) Mechanical spring charged / free indicator -01 No (iv) 1- Set of 6 Nos + 6 NC Aux contact block -01 No (v) DC 24 volt, shut strip -01 No (b) 1- Set space heaters 1x60 watt -03 nos, 230V AC with switch humidity sensor and thermostat. (c) VCB ON & OFF switch, trip circuit heating, auto trip, service position, test position. (d) 1-Set of Red/green indicating lamps for circuit breaker on/off auto trip indication. (e) 3 resin cast type twin secondary current transformer of ratio 300-100/5-5A, class of accuracy 0.5/5P10, burden 10VA/10 VA burden for protection & metering. (f) 1-3 phasing cast draw out type potential transformer ratio 11 KV root 3/ 110 V class 0.5 accuracy, 50 VA/ph burden, complete HT & LT fuses and connected to incoming side

-

-

-

... More
(g) Luminous push button for trip circuit check. (h) Microprocessor based numerical relay with local display & communication port. (j) Multifunctional Electronic Digital Meter in each VCBs consisting of measurement of current, voltage, frequency, KW, KWH, KWARH, RMD etc type PM 500. (k) 1 No- Cut out plate for cable entry for 95 sq mm 3 core cable. (l) PVC FRLS copper cable single core multi-stranded of size 2.5 sq mm for all control wiring. (m) MCB DP 32A -01 No for control supply. (n) Smart Electronic Digital Trivector Meter in main incoming VCBs consisting of measurement of current, voltage, frequency, KW, KWH, KWARH, RMD etc type PM 500. NOTE:- (i) Each VCB tripping coil voltage should be 30 VDC. (ii) Quoted rate is inclusive of Power pack unit for backup supply for the relay. (iii) The quantity of two VCBs will act as one unit such as 1 No Incoming and the other will act as Outgoing. (iv) Contractor shall provide drawings of 11 KV VCB panel for approval before procurement. The HT panels shall be factory inspected and routine test shall be carried out in the presence of rep of Accepting Officer.

-

-

-

... More
M & L for 300 cm dia cable route indicator made of CI plate 8 mm thick with spike to angle iron 25 X 25 X 5mm, 40 cm long marked as LT/HT cable jointing on conductor coil plate complete including fixing and excavation in soft/loose/hard/dense soil, PVC embedded, block size 300 X 300 X 300 mm (1:3:6) type C-1 using 20 mm graded stone aggregate complete all as specified and as directed.

75

-

-

... More
Supply, install, commission and testing cubical type Main LT panel board of size, outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.0mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories :- (Main Panel 01)

1

-

-

... More
INCOMING (a) ACB 4 pole, 415 Volts, 800 Amps, 50 KA (Manual Draw out type) - 01 No. OUTGOING (a) ACB 4 pole, 415 Volts, 800 Amps, 50 KA (Manual Draw out type) - 01 No (b) MCCB 4 pole, 415 Volts, 500 Amps,50 KA -01 No. (c) MCCB 4 pole, 415 Volts, 160 Amps,50 KA -02 Nos (d) MCCB 4 pole, 415 Volts, 32 Amps, 50 KA -01 Nos (e) MCB 2 pole, 230 Volts, 32 Amps, 10 KA -01 Nos (f) Digital VAF meter for basic electric system monitoring - 01 Nos (g) Indicator lamp (RYB) (set of three) - 01 Set

-

-

-

... More
Supply, install, commission and testing cubical type Main LT panel board of size ,outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.0mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories :- (Main Panel 2)

1

-

-

... More
INCOMING (a) MCCB 4 pole, 415 Volts, 320 Amps, 25 KA - 01 No. OUTGOING (a) MCCB 4 pole, 415 Volts, 500 Amps, 25 KA -01 No. (b) MCCB 4 pole, 415 Volts, 160 Amps, 25 KA -01 No. (c) MCCB 4 pole, 415 Volts, 80 Amps, 25 KA -01 No. (d) MCCB 4 pole, 415 Volts, 63 Amps, 25 KA -01 No. (e) Digital VAF meter for basic electric system monitoring - 01 Nos (f) Indicator lamp (RYB) (set of three) - 01 Set

-

-

-

... More
Supply, install, commission and testing cubical type Main LT panel board of size, outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.0mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories :- (P1)

1

-

-

... More
INCOMING (a) ACB 4 pole, 415 Volts, 800 Amps, 50 KA (Manual Draw out type) - 01 No. OUTGOING (a) MCCB 4 pole, 415 Volts, 630 Amps, 36 KA -01 No. (b) MCCB 4 pole, 415 Volts, 320 Amps, 36 KA -02 No. (c) MCCB 4 pole, 415 Volts, 16 Amps, 36 KA -05 No. (d) Digital VAF meter for basic electric system monitoring - 01 Nos (e) Indicator lamp (RYB) (set of three) - 01 Set

-

-

-

... More
Supply, install, commission and testing cubical type Main LT panel board of size ,outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.0mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories :- (P3)

1

-

-

... More
INCOMING (a) MCCB 4 pole, 415 Volts, 250 Amps, 25 KA -01 No. OUTGOING (a) MCCB 4 pole, 415 Volts, 160 Amps, 16 KA -01 No. (b) MCB 2 pole, 230 Volts, 32 Amps, 10 KA -02 No. (c) MCB 2 pole, 230 Volts, 16 Amps, 10 KA -05 No. (d) Digital VAF meter for basic electric system monitoring - 01 Nos (e) Indicator lamp (RYB) (set of three) - 01 Set

-

-

-

... More
Supply, install, commission and testing cubical type Main LT panel board of size, outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.0mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories :- (DG SUPPLY PANEL 01)

1

-

-

... More
INCOMING (a) MCCB 4 pole, 415 Volts, 160 Amps, 25 KA - 01 No. OUTGOING (a) MCCB 4 pole, 415 Volts, 80 Amps, 25 KA -01 No. (b) MCCB 4 pole, 415 Volts, 32 Amps, 25 KA -02 No. (c) MCCB 4 pole, 415 Volts, 16 Amps, 25 KA -01 No. (d) Digital VAF meter for basic electric system monitoring - 01 Nos (e) Indicator lamp (RYB) (set of three) - 01 Set Note: This Panel also includes AMF Panel; which contains Auto- Transfer switch and MCCB 4 pole, 415 Volts, 160A, 25 kA - 1 No.

-

-

-

... More
Supply, install, commission and testing cubical type Main LT panel board of size, outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.0mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories :- (DG SUPPLY PANEL 02)

1

-

-

... More
INCOMING (a) MCCB 4 pole, 415 Volts, 80 Amps, 25 KA - 01 No. OUTGOING (a) MCCB 4 pole, 415 Volts, 63 Amps, 25 KA -02 No. (b) MCCB 4 pole, 415 Volts, 16 Amps, 25 KA -01 No. (c) Digital VAF meter for basic electric system monitoring - 01 Nos (d) Indicator lamp (RYB) (set of three) - 01 Set Note: This Panel also includes AMF Panel; which contains Auto- Transfer switch and MCCB 4 pole, 415 Volts, 63A, 25 kA - 1 No.

-

-

-

... More
Supply, install, commission and testing cubical type Main LT panel board of size, outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.0mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories :- (Main LT Panel) (MLTP) (ADMIN BLOCK)

1

-

-

... More
INCOMING (a) MCCB 4 pole, 415 Volts, 630 Amps, 36 KA - 01 No OUTGOING (b) MCCB 4 pole, 415 Volts, 630 Amps, 36 KA - 02 No (c) Digital VAF meter for basic electric system monitoring -01 Nos (d) Indicator lamp (RYB) (set of three) - 01 Set

-

-

-

... More
Supply, install, commission and testing cubical type Main LT panel board of size, outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.0mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories :- (Utility Panel)(Admin Block)

1

-

-

... More
INCOMING (a) MCCB 4 pole, 415 Volts, 100 Amps, 25 KA - 01 No OUTGOING (b) MCCB 4 pole, 415 Volts, 50 Amps, 16 KA - 03 No (c) MCCB 4 pole, 415 Volts, 32 Amps, 16 KA - 01 No (d) MCB 3 pole, 415 Volts, 32 Amps, 10 kA - 03 Nos. (e) MCB 1 pole, 230 Volts, 16 Amps, 10 kA - 05 Nos (f) MCB 1 pole, 230 Volts, 20 Amps, 10 kA - 01 Nos (g) Digital VAF meter for basic electric system monitoring -01 Nos (h) Indicator lamp (RYB) (set of three) - 01 Set

-

-

-

... More
Supply, install, commission and testing cubical type Main LT panel board of size, outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.0mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories :- (MDB#06)(LT PANEL)(ADMIN BLOCK)

1

-

-

... More
INCOMING (a) MCCB 4 pole, 415 Volts, 160 Amps, 25 KA - 01 No OUTGOING (b) MCCB 3 pole, 415 Volts, 80 Amps, 16 KA - 02 No (c) MCB 3 pole, 415 Volts, 40 Amps, 10 kA - 01 Nos. (d) MCB 3 pole, 415 Volts, 32 Amps, 10 kA - 02 Nos. (e) Digital VAF meter for basic electric system monitoring -01 Nos (f) Indicator lamp (RYB) (set of three) - 01 Set

-

-

-

... More
Supply, install, commission and testing cubical type Main LT panel board of size, outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.0mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories :- (MDB#07)(LT PANEL)(ADMIN BLOCK)

1

-

-

... More
INCOMING (a) MCCB 4 pole, 415 Volts, 160 Amps, 25 KA - 01 No OUTGOING (b) MCCB 3 pole, 415 Volts, 80 Amps, 16 KA - 02 No (c) MCB 3 pole, 415 Volts, 40 Amps, 10 kA - 01 Nos. (d) MCB 3 pole, 415 Volts, 32 Amps, 10 kA - 02 Nos. (e) Digital VAF meter for basic electric system monitoring -01 Nos (f) Indicator lamp (RYB) (set of three) - 01 Set

-

-

-

... More
Supply, install, commission and testing cubical type Main LT panel board of size, outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.0mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories :- (MAIN LT PANEL)(MLTP)(Single Living Accn)

1

-

-

... More
INCOMING (a) MCCB 4 pole, 415 Volts, 160 Amps, 16 KA - 01 No OUTGOING (b) MCCB 3 pole, 415 Volts, 63 Amps, 16 KA - 02 No (c) MCCB 3 pole, 415 Volts, 32 Amps, 16 KA - 02 No (d) MCB 1 pole, 230 Volts, 63 Amps, 10 kA - 01 Nos. (e) MCB 3 pole, 415 Volts, 32 Amps, 10 kA - 01 Nos. (f) MCB 1 pole, 230 Volts, 16 Amps, 10 kA - 02 Nos. (g) Digital VAF meter for basic electric system monitoring -01 Nos (h) Indicator lamp (RYB) (set of three) - 01 Set

-

-

-

... More
Supply, install, commission and testing cubical type Main LT panel board of size, outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.0mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories :- (UTILITY Panel) (Single Living Accn)

1

-

-

... More
INCOMING (a) MCCB 4 pole, 415 Volts, 63 Amps, 16 KA - 01 No OUTGOING (b) MCB 3 pole, 415 Volts, 32 Amps, 10 kA - 03 Nos. (c) MCB 1 pole, 230 Volts, 63 Amps, 10 kA - 04 Nos. (d) Digital VAF meter for basic electric system monitoring -01 Nos (e) Indicator lamp (RYB) (set of three) - 01 Set

-

-

-

... More
Supply, installation, testing and commissioning of sandwich type (3L+N+PE) bus bar trunking system complete with two runs of 50 mm X 6 mm aluminium earthing strip and accessories all as specified and directed by engineer-in-charge. The BTS shall conform to the following technical specifications: [A] GENERAL [i] The bus bar trunking system (BTS), both feeder and plug-in, shall be of sandwich construction. All components and fittings (straight length, elbow, tee, flanged end, cable tap-off box and circuit breaker etc.) shall conform to IEC 61439-6:2012 or UL 857. [ii] The BTS shall have IP 66 protection with canopy for outdoor application and IP 54 protection for indoor application in accordance with IEC 60529: 1989. [iii] The rated operation voltage of BTS shall not be less than 1 kV. The neutral conductor shall have the same cross-sectional area as the phase conductor and the earth bus bar shall be provided on both sides of the housing.

-

-

-

... More
[B] CERTIFICATE [i] The bus bar, of full range and each rating, shall pass full type tests specified in IEC 61439-6-2012. The certificate shall be issued by an international independent testing authority, e.g. ASTA. KEMA. UL, ERDA, CPRI etc. [ii] A product safety mark, e.g. KEMA-KEUR, ASTA DIAMOND, UL and ERDA, CE, etc. shall be on the product offering a visual assurance of full product safety testing, factory inspection and ongoing surveillance under independent authority. [iii] The BTS shall be certified for seismic tests conforming to IEEE 693-2018 for seismic zone V.

-

-

-

... More
[C] SHORT-CIRCUIT RATINGS & TESTS [i] The entire BTS (bus duct and plug-in box assembly) shall be capable of withstanding the short-circuit of electrical installation without undergoing any electrical, mechanical or thermal stress under fault condition at a service voltage of 1 kV at 50 Hz frequency. The minimum rated insulation voltage shall be 1 kV. [ii] The minimum certified short-circuit withstand capacity for 1600 A rating shall be 80 kA for 1 sec.

-

-

-

... More
[D] HOUSING [i] The bus bar trunking housing shall be constructed of 1.6 mm thick electro-galvanized steel and shall be provided with a suitable protective finish of epoxy paint. [ii] The bus bar trunking housing shall be totally enclosed non-ventilated for protection against mechanical damage and dust accumulation and it shall be tested for its characteristics offering resistance against corrosion. It shall also pass at least 1000 salt spray test to ensure its anti-corrosion ability. [iii] The totally enclosed housing shall be manufactured by the BTS OEM and modifications of bus bar trunking to make it totally enclosed by housing other than the bus bar trunking OEM shall be unacceptable without written consent of the OEM.

-

-

-

... More
[E] BUSBARS [i] The bus bars shall be of aluminium with tin / silver plating at joint and conductivity of the joint shall be 60% IACS [ii] There shall be no bolts passing through the bus bars of the BBT. [iii] Each bus bar shall be insulated with Class-F (155⁰ C) multilayer PET insulation. Epoxy and Mica insulation shall be unacceptable. [iv] The temperature rise at any point of bus bar trunking enclosure shall not exceed 55⁰C above the ambient temperature of 40⁰ C when operated at the rated current.

-

-

-

... More
[F] JOINTS [i] The bus bar trunking joint shall be of one-bolt type utilizing high strength steel bolt(s) and Belleville washers to maintain proper pressure over a large contact surface area. [ii] The bolt(s) shall be torque indicating and at earth potential. [iii] The nut(s) shall be of two-headed design to indicate proper torque has been applied and shall require only a standard long handle wrench to be properly activated. [iv] Access shall be required to only see one side of the bus bar trunking to tighten joint bolts. [v] It shall be possible to remove any joint connection assembly to allow electrical isolation or physical removal of a bus bar trunking length without disturbing adjacent bus bar trunking lengths.

-

-

-

... More
[G] PLUG-IN OPENING [i] The connecting jaw of a plug-in unit shall plug directly onto the bus bar and have full contact with bus bar itself. Welded tab at plug-in bus bar is unacceptable. [ii] All contact on joint and plug-in opening shall be of copper strip in order to avoid external force damage on bus bar while plugging in or plugging out operation. [iii] On plug-in bus bar trunking there shall be three dead front, hinged cover type plug-in opening on each side. [iv] All openings shall be usable simultaneously. Bus bar trunking shall be installed in such a manner that plugs are side mounted to permit practical use of all plug-in openings. [v] It shall be possible to inspect the plug-in opening and bus bars prior to the installation of plug-in units.

-

-

-

... More
[H] SUPPORT STRUCTURE [i] Support structure shall be provided as per OEM's recommendation. [ii] Indoor feeder and plug-in bus bar trunking shall be approved for hanger spacing of up to 3 m for horizontally mounted run and 4.88 m for vertically mounted runs. Outdoor feeder bus bar trunking shall be approved for spacing up to 1.5 m for horizontally or vertically mounted runs.

-

-

-

... More
[I] VOLTAGE DROP [i] The voltage drop (sending end voltage minus receiving end voltage) specified shall be based on the bus way operating at full rated current and stabilized operating temperature in [ii] The 3- Phase line to line voltage drop shall not exceed 3.4 V per 100 feet length at 40% power factor concentrated load which may exist during motor starting. [iii] The line to line voltage drop shall not exceed 4.1 V per 100 feet at the load power factor which produces the maximum voltage drop in the bus way.

-

-

-

... More
[J] INSPECTION / SUPPORT OF INSTALLATION [i] The installation of bus bar trunking system (BTS) shall be executed by skilled professionals with minimum experience of 4 yrs. having sufficient installation base and pre-commissioning experience. [ii] The entire installation shall be directly supervised by the OEM. [iii] The OEM shall also furnish a commissioning report underlining satisfactory installation after the commissioning of BBT system.

-

-

-

... More
800 A BBT (ADMIN BUILDING)

-

-

-

... More
IP66 rated straight / plug-in / tap-off feeder length

50

-

-

... More
Vertical elbow

2

-

-

... More
Horizontal elbow

2

-

-

... More
Vertical offset elbow

1

-

-

... More
Horizontal offset elbow

1

-

-

... More
Vertical tee elbow

1

-

-

... More
Flanged end

2

-

-

... More
Plug-in box with mechanical interlocking (16-100 A)

5

-

-

... More
Tap-off box (125-250 A)

2

-

-

... More
Horizontal supports

5

-

-

... More
Vertical fix hanger

20

-

-

... More
Vertical spring hanger

15

-

-

... More
Wall flange / floor flange

15

-

-

... More
Flexible copper braid

2

-

-

... More
End feed unit along with 630 A, 50 kA MCCB

1

-

-

... More
M & L for shifting existing Transformer from old substation to new substation via suitable transportation after disconnecting all cables and fixed again at new substation with suitable PCC (1:3:6) foundation and fixing all cable connection with lugs complete all as specified and directed.

1

-

-

... More
M&L for AAC block masonry in cement mortar 1:6 straight or curved on plan exc 6 mtr mean radius complete all as specified and as directed.

540

-

-

... More
S&F for concertina coil fencing with punched tape 600mm dia (before stretching) with 10-12 stands of SRPBT (Super Razor Punched Barb Tape) wire of minimum dia 2.59mm tensile strength of 1620 N/Sq.mm with anti rust bituminous coating conforming IS-4454 part-I/1981 grade-II, for respective materials incl all fixing arrangements as per manufactures instruction for fixing & erection complete all as directed by Engr-in-Charge.

3847

-

-

... More
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts indoor type, factory made CPRI approved free standing, floor mounting, dust vermin proof cubical type, LT Panel fabricated from 3 mm thick CRCA sheet with anticorrosive coating and finally epoxy polyester powder coating of flint Grey shade fully compartmentalized design with 4 Nos of copper bus bar of 200 Amps capacity each and PCC foundation and Angle iron is included in quoted rate as following :- Incoming:- (a) MCCB 32 A, 4 pole 16 KA-I No (b) Ammeter 0-40 Amps 96 mm square digital type (c) Voltmeter -500V -01 No digital type 96 mm square (d) 01 set of 3 nos LED indication lamp. Outgoing :- (a) MCCB 25 Amps 16 KA TP, 415 Volt -03 Nos (2 pumps & one spare) (b) Fully automatic star delta starter complete with contactor relay and single phase preventer etc of capacity 2 HP- 02 Nos (c) Single phase protection - 02 Nos

1

-

-

... More
Supply & fixing Monoblock pump set suitable for 415 V, 3 phase system having capacity 2 HP and connection from starter to pump motor complete all as specified and directed.

2

-

-

... More
Material and labour for construction of valve chambers of size 750x750x750 mm depth including excavation and earthwork. PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 150 mm thick & 150 mm wide offsets around over 100 mm thick hardcore, 200 mm thick PCC block masonry walls built in CM 1:4, 100 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/dense soil 6 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.

1

-

-

... More
S&F GI water tubing ISI marked medium grade of 65mm NB including all fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accessories such as pipe hooks, screws, clamps etc fixed complete to walls and ceilings or laid in floors all as specified and as directed:

23.5

-

-

... More
S&F Bib taps, Two-way, 15mm bore, cast copper alloy, fancy type, chromium plated with crutch handle, long body with wall flange, screwed down, screwed for iron pipe or for brass ferrule all as specified and as directed.

113

-

-

... More
S&F 15mm bore Push Cock cast copper alloy chromium plated, for urinal complete screwed down for iron pipe all as directed.

36

-

-

... More
Supply & Fixing 15 mm bore Brass chromium plated Wall Mixer (2 in 1) for mixing hot & cold water, screwed down for iron pipe including all fittings and flange etc. complete all as specified & as directed.

24

-

-

... More
S&F gun metal globe or gate valve of 65mm bore conforming to IS 9338, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.

2

-

-

... More
Dismantling 100mm bore cast iron drain pipes laid in floor/ fixed to walls

136

-

-

... More
Dismantling 75mm bore cast iron drain pipes laid in floor/ fixed to walls

130

-

-

... More
Taking down sub main wiring of any size including surface conduit if any all as directed.

350

-

-

... More
Uprooting and taking down street light pole including bracket etc. including necessary excavation, breaking up concrete foundation/ coping etc. complete all as directed.

2

-

-

... More
Taking down security light fitting of any type/ wattage all as directed.

6

-

-

... More
Disconnecting and taking down feeder pillar panel of any size/ type complete all as directed.

3

-

-

... More
Disconnecting and taking up LT UG cables of any size/ type including necessary excavation and earth work complete all as directed.

160

-

-

... More
Disconnecting and taking down existing ceiling fan/ exhaust fan/ wall mount fan/ geyser of any size and handing over to MES store yard complete all as directed

60

-

-

... More
Disconnecting and taking down existing Air conditioner of any type/ capacity from their location and handing over to MES store yard complete all as directed

13

-

-

... More
Schedule "A" Part - XIX: Manning & Operation and Comprehensive maintenance of lifts

-

-

-

... More
Outsourcing of services for operation of the following Electrically operated Lifts installed in 2 buildings by deploying 2 operators in each shift with two shifts of 8 hours each per day + 01 rescue operator during night shift of 08 hours complete during 1st year of Defect Liability Period: (i) 02 lifts of 13 passenger (884 kg) capacity in one buildings consisting Stilt + 7 upper floors (Total 2 lifts) (ii) 01 lift of 13 passenger (884 kg) capacity & 01 lift of 8 passenger (544 kg) capacity each in one buildings consisting Stilt + 4 upper floors (Total 2 lifts)

12

-

-

... More
All as per Item No 159 herein before but during 2nd year of Defect Liability Period.

12

-

-

... More
All as per Item No 159 herein before but during 1st year after expiry of Defect Liability Period.

12

-

-

... More
All as per Item No 159 herein before but during 2nd year after expiry of Defect Liability Period.

12

-

-

... More
All as per Item No 159 herein before but during 3rd year after expiry of Defect Liability Period.

12

-

-

... More
Comprehensive maintenance including periodical maintenance of electrically operated passengers lifts catered under Item No. 63.00 to 65.00 herein before, during 1st year after Defect Liability Period as per OEM recommendation, repairs/ rectification of defects including renewal/ replacement of all defective parts through respective OEM of the lifts complete all as specified and as directed. (Total No of Lifts- 04 Nos)

12

-

-

... More
All as per Item No 164 herein before but during 2nd year after expiry of Defect Liability Period.

12

-

-

... More
All as per Item No 164 herein before but during 3rd year after expiry of Defect Liability Period.

12

-

-

... More
Schedule "A" Part - XX: Manning & Operation of package type STP

-

-

-

... More
Outsourcing of services for operation and maintenance of 15 KLD capacity package type STP by deploying one operator in each shift with two shifts of 8 hours each per day complete during 1st year of Defect Liability Period complete including rovision of requisite consumable chemicals/items, monitoring of all mechanical & electrical equipment, analysing the treated water sample once in a month all as directed.

12

-

-

... More
All as per Item No 167 herein before but during 2nd year of Defect Liability Period.

12

-

-

... More
All as per Item No 167 herein before but during 1st year after expiry of Defect Liability Period.

12

-

-

... More
All as per Item No 167 herein before but during 2nd year after expiry of Defect Liability Period.

12

-

-

... More
All as per Item No 167 herein before but during 3rd year after expiry of Defect Liability Period.

12

-

-

... More
Deduct: Amount of Schedule of Credit b/f from Sl. Page No. 32 of tender document i.e. Rs. 6,02,925.00

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.