Military Engineer Services Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date7 Jan 2025
Closing Soon6 Feb 2025
Tender Amount₹ 39,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/cupboard & other Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately)complete all as specified and as directed. Note: For WPC solid door/cupboard frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.

95

-

-

... More
S & F 30mm thick flush shutters, solid core construction, with blockboard core and plywood face panels, commercial type on both sides complete all as specified and as directed.

20

-

-

... More
S&F for factory made 35mm thick 2nd class hard wood gauged and skeleton shutter open rebated and prepared to received gauge etc (without sash bars) for fly proof door shutter, edges of framing plain, chamfered or rounded, fitted with cut of any mitred beads for securing gauge etc, size of members of shutter as specified in SSR Part-I section 8 clause No.8.23(a) and fitted to chowkats complete all as specified and as directed.

20

-

-

... More
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face &2mm prelam PVC Sheet on back face supplying & fixing in frame at site as per specification with Wood free EPS complete all as specified and as directed.

27

-

-

... More
S&F of Stainless steel butt hinges, medium weight cold rolled of size 100mm complete all as specified and as directed.

60

-

-

... More
S&F of aluminium handles cast type anodised 150mm of size complete all as specified and as directed.

88

-

-

... More
S&F of 150mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and as directed.

40

-

-

... More
All as per item No 10 above but 200mm long barrel tower bolt of extruded section complete all as specified and as directed.

48

-

-

... More
S&F Aluminium alloy anodised sliding door bolt 250 mm long with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section complete all as specified and as directed.

12

-

-

... More
S&F factory made pressed steel windows of standard size and section as shown on HQ CE Siliguri Zone Drawing No CESZ/2018/TD-07, Sheet 1/3 to 3/3 with glazing bars including all fittings like MS hold fast, box hinges, Handles , MS Tower Bolts, Stoppers, hinges, MS stay with long screw, MS spring latch, MS Guard Bar/ grill etc complete with glazing bars including one shop coat of zinc chrome primer and taking down old one complete all as specified and as directed. Notes:- (a) Rate quoted shall be deemed to be including of all fittings & fixtures. (b) Glass, wire mesh, MS Guard Bar/grill and painting shall be measured and paid separately wherever applicable under relevant items of Sch. (c) The Drawings referred above are available in the office of Engr-in-Charge and can be referred in the office working hours if required. .

35

-

-

... More
All as per item No. 13 above but for steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and as directed.

8

-

-

... More
M&L for mild steel framed work such as grills, MS guard bar, gratings etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.

400

-

-

... More
Dismantling of asbestos cement ( corrugated, semi corrugated etc) sheets as in roof coverings including ridge complete all as specified and as directed.

50

-

-

... More
Dismantling ballies, hard or soft wood, any position, except in posts and struts; including taking out iron straps, bolts and nuts, etc complete all as specified and as directed.

50

-

-

... More
S&F for pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.

50

-

-

... More
S&F of rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantry, rails, fastening, heavy bracket framing (Beam, tee, angle, channel or flat section, Tube etc) including distance pieces, cleats etc. confirming to Fe - 410- W including cutting, welding & necessary fittings such as nut bolt, plate etc. complete all as specified and as directed.

654

-

-

... More
M&L for preparation of new of previously untreated steel and Iron surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed.

38

-

-

... More
M&L for preparation of new or previously undecorated wooden surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.

84

-

-

... More
Hacking out old broken unserviceable glass panes (any thickness, size, quality or description) for metal frame including punching or drilling out old glazing pins/spring clips and providing & fixing new one complete all as specified and as directed.

40

-

-

... More
S&F of 4 mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and as directed.

52

-

-

... More
S&F Figured glass, pin head type 3mm thick in squares n.exc 0.50 Sqm in each pane complete all as specified and as directed.

8

-

-

... More
M&L for PCC type C-1, 1:3:6 using 20mm graded aggregate as in bed block for fixing of hold fast, filling concrete in frame filling , gaps in between glazed & fly proof steel window, cills, railing up to 60 cm in height etc including necessary form work as required complete all as specified and as directed.

0.5

-

-

... More
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed.

55

-

-

... More
S&F in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed.

30

-

-

... More
Taking down cement plaster on wall of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.

1460

-

-

... More
M&L for 20 mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm+10 mm) with ready mixed pre-packed proportioned dry mix mortar blended with PP fibers, mixed with liquid water proofing compound on other than fair faces of brick wall or concrete surfaces additives on external surfaces incl. transporting of material, mixing, curing, scaffolding etc finished the surfaces even and fair without using extra cement complete all as specified and as directed. Note : WPC will be measured and paid separately.

400

-

-

... More
M&L for rendering 5 mm thick cement plaster on ceiling cement mortar (1:3) finished the surfaces even and fair without using extra cement complete all as specified and as directed.

200

-

-

... More
M&L for rendering 15 mm thick plastering in CM (1:6) for finished even and fair (without using extra cement) complete all as specified and as directed.

550

-

-

... More
Supply only liquid water proofing compound complete all as specified and as directed.

10

-

-

... More
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer after applying 2 coats of cement based wall putty 1 mm each to wall surface complete all as specified and as directed.

550

-

-

... More
M&L for one coat of oil bound distemper on wall of old surface over Chalk whiting, on plastered surfaces, preparatory to distemper and brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc all as spd and as directed.

350

-

-

... More
M&L for preparation of newly ceiling plastered surfaces and applying three coats of white wash on wall complete all as specified and as directed.

200

-

-

... More
M&L for one coat of white wash on ceiling of old surface with preparation of old surface shall include brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots complete all as specified and as directed.

300

-

-

... More
M&L for preparation of newly wall plastered surfaces and applying three coats of white/colour wash on wall to match the existing colour complete all as specified and as directed.

400

-

-

... More
M&L for one coat of white/Colour wash on wall of old surface with preparation of old surface shall include brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots complete all as specified and as directed.

450

-

-

... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises including taking down cement plaster complete all as specified and as directed.

335

-

-

... More
M&L for non skid coloured joint free ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but n. exc. 0.18 Sqm, in floors etc. set and jointed in neat cement slurry over 15mm thick screed bed or bedding layer in CM (1:6) as in floor and pointed in whiter or coloured cement to match as in floor complete all as specified and as directed.

75

-

-

... More
M&L Glazed ceramic coloured tiles in vertical surface 450x350x7mm thick set and jointed in neat cement slurry and pointed white or colour cement to match complete all as specified and as directed.

260

-

-

... More
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces to receive a wall tiles using cement mortar 1:4 complete all as specified and as directed.

260

-

-

... More
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and as directed.

875

-

-

... More
M&L for machine cut pre polished kota stone slab flooring 15-20 mm thick over 15mm thick cement screed bed using cement mortar (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing(mirror finish) complete all as specified and as directed.

745

-

-

... More
M&L for machine cut pre polished kota stone riser/skirting 15-20 mm thick over 15mm thick rendering using cement mortar (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and beewax polishing complete all as specified and as directed.

100

-

-

... More
M&L for machine cut kota stone slab flooring 15-20 mm thick for staircase step(treads) in single piece(of length not less then 1200 mm) laid over and including 15mm thick (average thickness) cement mortar (1:6)screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish) complete ,including provision of two nos 3x3mm grooves at tread of each step complete all as specified and as directed.

20

-

-

... More
M&L for machine cut kota stone slab 15-20 mm thick on vertical surfaces like riser of steps, skirting in single piece(of length not less then 1200 mm) laid over and including 15mm thick (average thickness) cement mortar (1:6)screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish) complete ,including provision of two nos 3x3mm grooves at tread of each step complete all as specified and as directed.

10

-

-

... More
M & L for 18 to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window cills, cooking platforms, corner shelf, Flat shelf and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including 15 mm thick cement plaster (1:6) including rounding the exposed surfaces of granite complete all as specified and as directed.

5

-

-

... More
Demolition of cement concrete (un-reinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and as directed.

6

-

-

... More
M&L for 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in path ,steps and plinth protection laid with and including use and waste of form work and finishing the surface even and smooth/rough to receive the topping layer or tiling complete all as specified and as directed.

80

-

-

... More
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 15 mm bore complete all as specified and as directed.

90

-

-

... More
S&F of Tubes, medium grade, 15mm bore, galvanised, with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified and as directed.

80

-

-

... More
Refixing of old steel tubing and connections in new or old position (wall, ceiling, floors, etc) of 15 mm bore complete all as specified and as directed. Note: The serviceable GI tubing obtained from taking down shall be reused.

10

-

-

... More
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exceeding 10 cm girth in brick walls complete all as specified and as directed.

80

-

-

... More
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 20 mm bore complete all as specified and as directed.

60

-

-

... More
S&F of Tubes, medium grade, 20 mm bore, galvanised, with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified and as directed.

35

-

-

... More
Refixing of old steel tubing and connections in new or old position (wall, ceiling, floors, etc) of 20 mm bore complete all as specified and as directed. Note: The serviceable GI tubing obtained from taking down shall be reused.

25

-

-

... More
S&F in repair stainless steel curtain rod 25mm dia thickness not less than 0.63 mm, fixed with curtain rod holder and finials(to be paid separately) complete all as specified and as directed.

90

-

-

... More
S&F stainless steel curtain rod holding bracket heavy duty fixed to wall with stainless steel screws complete all as specified and as directed.

30

-

-

... More
S&F stainless steel finial type stop end suitable for curtain rod 25mm dia as approved by GE complete all as specified and as directed.

30

-

-

... More
Dismantling water tank exc 500 & n.exc 1000 ltr capacity and removing to store complete all as specified and as directed.

6

-

-

... More
S&F 1000 ltrs capacity rotational moulded polyethylene water storage triple layer (cylindrical vertical with closed top) hoisted and fixed in positions complete all as specified and as directed.

6

-

-

... More
S&F in repair of ball valves of 20mm bore high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe & fixed (Minimum weight 20 gms-210 gms) complete all as specified and as directed.

6

-

-

... More
S&F in repairs 15 mm dia Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.

28

-

-

... More
S&F in repair 15 mm bore two way bip taps CP with flage complete all as specified and as directed.

4

-

-

... More
S & F in repair concealed stop cock CP, cast copper alloy fancy type with long shank and cup for 15mm pipe complete all as specified and as directed.

4

-

-

... More
S&F in repair of CP swivel shower for fixing with 15 mm pipe including Shower arm 15 mm size, 195 mm long with bend of 45 degree with flange etc complete all as specified and as directed.

4

-

-

... More
S & F ceramic undercounter wash hand Basin Glossy finishes, size 22x16x8 inch size including CP waste coulping, PVC connection 450 mm long, waste pipe and removing the existing Basin, cutting for and pinning ends of brackets or erecting stand complete all as specified and as directed.

16

-

-

... More
Supply and Fix in repairs 15 mm bore long body pillar taps, capstan head, cast Copper alloy, chromium plated, screwed down high pressure with or without lettered ‘HOT’ or ‘COLD’ long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.

16

-

-

... More
S&F beveled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed.

13

-

-

... More
S&F for 75 mm dia Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.

20

-

-

... More
S&F in repair vitreous china squatting pan "Orissa" pattern size 580x440mm white with integral foot rests(excluding flushing cistern and flush pipe) with 'P' or 'S" trap fron or back inlet etc including connection to trap tand flushing pipe and provision of lime concrete bedding complete all as specified and as directed in repairs including demolition of existing one complete all as specified and as directed.

8

-

-

... More
S&F in repair EWC Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and as directed.

4

-

-

... More
M&L for PVC water closet seat cover, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.

4

-

-

... More
S&F in repair health faucet connecting with 15mm dia pipe with chromium plated (CP) finishing etc complete all as specified and as directed.

4

-

-

... More
S&F in repair 10 ltr capacity PVC flushing cistern low level white colour including PVC connection 450 mm long, PVC flush pipe of required length etc complete all as specified and as directed

12

-

-

... More
S&F in repair Vitreous China Urinal, Half stall type, white with flush pipe, connecting pipe & waste pipe, CP urinal spreader complete all as specified and as directed.

4

-

-

... More
S&F in repair 15 mm dia brass chromium plated angle cock complete all as specified and as directed.

40

-

-

... More
S&F brass chromium plated Tubular towel rail 20mm dia of D type 60 cm long between flange complete all as specified and as directed.

8

-

-

... More
S&F PVC (SWR) multi floor trap 75MM/100mm , plain with grating including jointing with solvent cement complete all as specified and as directed.

16

-

-

... More
Taking down AC/PVC pipe including all fittings complete all as specified and as directed.

63

-

-

... More
S&F 110mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and as directed.

60

-

-

... More
S&F 110mm dia PVC SWR bends of any radius with out access door complete all as specified and as directed.

12

-

-

... More
S&F 110mm dia PVC (SWR) junction single 'T' equal or unequal with access door complete all as specified and as directed.

10

-

-

... More
S&F 110mm dia PVC (SWR) branch piece, single ‘Y‘ equal or unequal complete all as specified and as directed.

4

-

-

... More
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.

1

-

-

... More
M&L RCC type B1 (1:2:4) using 20 mm graded aggregate in Fins, fascias, louvres, parapets, and railings , newels, slab, balustrade & the like complete all as specified and as directed.

1

-

-

... More
Formwork to fins, louvers, fascia. etc Fair finished surfaces of concrete flat complete all as specified and as directed.

30

-

-

... More
M&L for Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and as directed.

60

-

-

... More
Demolition of brick work built in cement mortar including all quions, arches, pillars etc complete all as specified and as directed.

3

-

-

... More
M&L for fly ash brick work straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed.

3

-

-

... More
M&L for water proofing treatment to sunken floor with the following course of treatment/ specification: (i) Cleaning top surface of floors /slabs and laying 50 mm thick (avg) PCC of grade M10 (Nominal mix) , mixed with WPC as per manufactrrer's instruction laid in slope 1:20 towards spouts including coveting corners (ii) 15 mm thick plastering in CM (1:4) on sides mixed with WPC as per rmanufacturer's instruction. (iii) Applying 1st layer of slurry @ 0.488 kg / sqm mixed with acrylic based polymer modified cementious compound @ 0.253 kg /sqm This layer shall be allowed to air cured for 4 hrs. (iv) applying 2nd layer of slurry @ 0.242 kg/sqm mixed with acrylic based polymer modified cementenous compound @ 0.126 kg/sqm.This layer shall be allowed to air cured for 4hrs followed with water curing for 48 hrs.(v) Applying a coat of industrial bitumen 85/25 penetration @ 1.50 kg/sqm on plastered and concrete surfaces (vi) Providing 150 micron thick polyutethene paint in two coats (each of 75 micron measured dry on dry surface over a coat of PU primer including preparation. (Make of PU primer - Dek guard EP -302 of M/S Fosroc or techno commercially equivalent approved brand as listed in List of Makes. Make of PU paint - Dek guard PU or techno commercially equivalent approved brand as listed in List of Makes. (vii) 2 Nos 32mm bore GI medium grade 450mm long spout ,to be provided through external wall to drain out accumulated water.(vii) Sunken floor shall be tested for water tightness by filling water for 72 hrs before and after treatment work is carried out and ensure that no leakage /seepage exists. (ix) Sunken portion shall be filled with lean concrete of grade M7.5 stone aggregate.

20

-

-

... More
Taking down tarfelt with cement plaster from roof surfaces and lowering and removing the same to a distance exc. 50m and n. exc. 100m including roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and as directed.

408

-

-

... More
M&L for 10mm thick screed bed or bedding layer in cement mortar (1:4) mixed with WPC in order to maintain proper slope over existing roof surfaces for applying roof treatment, finished even and fair without using extra cement complete all as specified and as directed. Note: WPC will be measured and paid separately.

408

-

-

... More
M&L for providing, cement concrete type B1 1:2:4 using 20 mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edges, padding on roof (where ever required) etc complete all as specified and as directed.

1

-

-

... More
M&L for waterproofing Coating with polyurethane based water proofing liquid membrane of approved make to be applied by brush with multi coats with minimum dry film thickness of 1mm and shall be cured by reaction with atmospheric moisture to give a tough elastomeric waterproof membrane including laying of standard PVC fabric mesh after laying of first layer of polueuthane based water proofing liquid membrane complete all as specified and as directed. Note: the above treatment will be carried out by authorised applicator of approved firm/company.

408

-

-

... More
INTERNAL ELECTRIFICATION Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.

206

-

-

... More
M&L for point wiring complete for one power point for one metal plug & socket for geyser point on independent board with 4.0 sqmm multistranded copper conductor single core PVC insulated unsheathed FR LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non metallic rigid PVC medium grade conduit not less than 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 4.00 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor connected to common earth dolly, including cutting chases of existing wall for conduits and fisxing for metal plug and socket boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles complete all as specified and as directed.

4

-

-

... More
M&L for point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with multistranded copper conductor with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheated copper conductor cable FR-LS (ISI marked) with proper colour coding as earth continuity conductor connected to common earth dolly , MS sheet steel sunken terminal box of appropriate size suitable for piano type switch/ fittings concealed in walls, with sheet back plate, top cover fixed flush to wall for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. all as specified and as directed for the following :-

-

-

-

... More
One light point controlled by one way switch 5/6 amps complete all as specified and as directed.

95

-

-

... More
One ceiling fan/Exhaust fan/Wall Fan point controlled by one way switch 5/6 amps complete all as specified and as directed.

38

-

-

... More
One socket out let 5/6 amps point on the independent board complete all as specified and as directed.

40

-

-

... More
One socket out let 5/6 amps point on the same board complete all as specified and as directed.

25

-

-

... More
All as per item No 99 above but wiring with 2.5 sq mm single core multistranded copper conductor including provision of 2.5 Sqmm PVC insulated multistranded unsheated copper conductor cable FR-LS (ISI marked) with proper colour coding as earth continuity conductor connected to common earth dolly , for one socket out let 15/16 amps point on the independent board complete all as specified and as directed.

4

-

-

... More
S&F switch piano flush type 5/6 amps single pole one way complete all as specified and as directed.

198

-

-

... More
S&F Switch socket combination 3 and 5 Pin, 5/15 amps, multipurpose flush non shutter, non inter locking type white ivory finish with, complete all as specified and as directed.

4

-

-

... More
S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and as directed.

65

-

-

... More
S&F Switch socket combination 3 and 5 Pin, 5/6 amps, multipurpose flush non shutter, non inter locking type white ivory finish with, complete all as specified and as directed.

4

-

-

... More
S & F in deluxe fan Electronic regulator 120/280 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and as directed.

30

-

-

... More
S & F lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and as directed.

15

-

-

... More
S&F LED white glass Lamp 1x9 Watt 230V Base-22 complete all as specified and as directed.

15

-

-

... More
S&F in ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and as directed.

118

-

-

... More
S&F IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency 95 lumens/watt, power factor 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified and as directed.

70

-

-

... More
S&F IP 20, Class I, LED Mirror light fitting 1 x 9 W, (or nearest next higher wattage) 5700 K, wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser, integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy 95 lumens/Watt, power factor / 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete including 01 No 10 W LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size including necessary taking down the old unserviceable fitting complete all as specified and as directed.

4

-

-

... More
S & F Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.2 mtr long bend to required shape complete including removal of old unserviceable fitting complete all as specified and as directed.

8

-

-

... More
Taking down carefully Ceiling fan from its original position and refixing / hanging after plaster work including painting of ceiling fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc complete all as specified and as directed.

30

-

-

... More
Material and labour for concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x6.0 sqmm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, including taking down old unserviceable aluminium submain wiring all as specified and as directed. Note : Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with proper colour coding including one run of PVC conduit shall be measured as one unit length. Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles complete all as specified and as directed.

115

-

-

... More
S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 amps rated bus bar, 415Volt IP-20 protection suitable for fixing MCB"S/lsolators with and including taking down old one complete all as specified and as directed.

1

-

-

... More
S&F MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 8 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, earth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface including taking down old one complete all as specified and as directed.

4

-

-

... More
S&F MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 4 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, earth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface including taking down old one complete all as specified and as directed.

2

-

-

... More
S&F MCB, Triple pole & neutral 63 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed.

1

-

-

... More
S&F MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unserviceable one complete all as specified and as directed.

14

-

-

... More
S&F MCB, Single pole, 5 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete with and including taking down old unserviceable one as complete all as specified and as directed.

35

-

-

... More
M&L for sheet metal enclosure fabricated out of 2.0 mm thick CRCA sheet, totally enclosed type, dust & vermin proof, with suitable sized supporting MS angles & suitable openings at top & bottom for entry of outgoing / incoming cables, fixed with nuts & bolts & front side openable with hinged shutter with suitable locking arrangement duly painted with 2 coats of powder coated paint over a coat of red oxide primer (spray paint) with minimum dimensions (90 x 75 x 20 cm ) flush to wall for incorporating 01 No TPN DB, 04 Nos electronic meters etc complete all as specified and as directed.

1

-

-

... More
Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, check nuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, including necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel and PCC cover complete all as shown in electrical plate No 3 of SSR Part- I including testing complete all as specified and as directed.

1

-

-

... More
S&F for SPN enclosure with two pin and earth plug and socket with 240 volts 32 Amp SPN MCB including removal old unserviceable one complete all as specified and as directed.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.