Military Engineer Services Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date26 Nov 2024
Closing Soon23 Dec 2024
Tender Amount₹ 45,00,000
Costs
EMD
₹ 90,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_685660_1Tender No
8393/SEV OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Materials and labour for 50 mm outer dia double wall corrugated (DWC) HDPE pipe, ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed.
3600
-
-
... More
Materials and labour for 75 mm outer dia double wall corrugated (DWC) HDPE pipe, ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed.
760
-
-
... More
Materials and labour for GI tubing of 40 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring/ laid on floor as cable protection all as specifed and directed.
25
-
-
... More
Materials and labour for GI tubing of 50 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring/ laid on floor as cable protection all as specifed and directed.
30
-
-
... More
Materials and labour for GI tubing of 80 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring/ laid on floor as cable protection all as specifed and directed.
30
-
-
... More
Supply and laying in trenches/wall LT UG XLPE insulated ,armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 240 sq mm x 3.5 core including taking down old unserviceable cable and making necessery connections all as specified and as directed.
50
-
-
... More
All as item no 9 but of size of cable 185 sqmm 3.5 core
50
-
-
... More
All as item no 9 but of size of cable 150 sqmm 3.5 core
50
-
-
... More
All as item no 9 but of size of cable 120 sqmm 3.5 core
100
-
-
... More
All as item no 9 but of size of cable 95 sqmm 3.5 core
200
-
-
... More
All as item no 9 but of size of cable 70 sqmm 3.5 core
500
-
-
... More
All as item no 9 but of size of cable 50 sqmm 3.5 core
500
-
-
... More
All as item no 9 but of size of cable 25 sqmm 4 core
500
-
-
... More
All as item no 9 but of size of cable 16 sqmm 4 core
1500
-
-
... More
All as item no 9 but of size of cable 16 sqmm 2 core
500
-
-
... More
All as item no 9 but of size of cable 10 sqmm 4 core
1000
-
-
... More
All as item no 9 but of size of cable 10 sqmm 2 core
500
-
-
... More
Supply and fixing Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws of type 410 SP-31 ( 9 metre long) including taking down old unserviceable RCC pole complete all as specified and directed.
10
-
-
... More
Supply and fixing cable jointing kit for 1.1 KV grade for straight through joint cold shrink type, complete with jointing material and accessories suitable for 3.5 core XLPE, armoured, aluminium conductor cable of size 70 to 185 Sqmm, Outdoor type, including taking out old damaged joint kit complete all as specified and as directed. (Note:- Excavation and connected items will be measured and paid separately)
5
-
-
... More
Supply and fixing cable jointing kit for 1.1 KV grade for straight through joint heat shrink type, complete with jointing material and accessories suitable for 3.5/4 core XLPE, armoured, aluminium conductor cable of size 16 to 50 Sqmm, complete all as specified and as directed. (Note:- Excavation and connected items will be measured and paid separately)
15
-
-
... More
Materials and labour for PCC, type C1, (1:3:6), using 20mm graded crushed stone aggregated, as in coping of poles including formwork including demolition of old damaged concrete from pole complete all as specified and as directed
1
-
-
... More
Materials and labour PCC, type D2, (1:4:8), using 40mm graded crushed stone aggregated, as in PCC on road cutting /installation area and foundation of pole etc complete all as specified and as directed.
10
-
-
... More
Materials and labour for boring holes 1mtr deep in soil under roads/PCC as directed for cable passing through pipes of required size and disposal of soil to a distance not exc. 50m. (Note: Connected items like Pipes is measured and paid seperately under relevant items).
30
-
-
... More
Supply and fixing in repair Indicator lamp (AC/DC), LED, type for as per existing fitting.complete all as specified and as directed by Engr-in-Charge.
2
-
-
... More
Supply and fixing in repair 3 Phase LED Ammeter complete all as specified and as directed by Engr-in-Charge.
3
-
-
... More
Supply and fixing in repair, 3 phase LED Voltmeter complete all as specified and as directed by Engr-in-Charge.
3
-
-
... More
Supply and fixing as in repairs MCCB four pole , 415 Volt, 63 Amps,16 KA , fixed thermal & magnetic setting including spreader link for incoming & outgoing cables complete all as specified and directed
3
-
-
... More
Supply and fixing as in repairs MCCB four pole , 415 Volt, 100 Amps,25 KA , fixed thermal & magnetic setting including spreader link for incoming & outgoing cables complete all as specified and directed .
5
-
-
... More
Supply and fixing as in repairs MCCB four pole , 415 Volt, 125 Amps,25 KA , fixed thermal & magnetic setting including spreader link for incoming & outgoing cables complete all as specified and directed.
1
-
-
... More
Supply and fixing MCCB, 160 Amps, 4P, 25 kA, 415 Volts, with adjstable thermal release & adjustable magnetic release including spreader link for incoming & outgoing cables complete including taking down old unserviceable MCCB complete all as specified and as directed. .
3
-
-
... More
Supply and fixing MCCB, 200 Amps, 4P, 25 kA, 415 Volts, with adjstable thermal release & adjustable magnetic release including spreader link for incoming & outgoing cables complete including taking down old unserviceable MCCB complete all as specified and as directed.
3
-
-
... More
Supply and fixing MCCB, 250 Amps, 4P, 25 kA, 415 Volts, with adjstable thermal release & adjustable magnetic release including spreader link for incoming & outgoing cables complete including taking down old unserviceable MCCB complete all as specified and as directed.
3
-
-
... More
Supply and fixing MCCB, 400 Amps, 4P, 36 kA, 415 Volts, with adjstable thermal release & adjustable magnetic release including spreader link for incoming & outgoing cables complete including taking down old unserviceable MCCB complete all as specified and as directed.
1
-
-
... More
Materials and labour for earthing complete with galvanized steel pipe electrode 40mm bore, medium grade, 3.5 meters length, buried directly and preferably vertically in ground with top edge not less than 1.25 meters below ground level connected with earthing lead galvanized iron strip of size 25x4 mm connected to galvanized earth pipe by means of bolts, nuts, checknuts and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanized steel tube for watering with one end fix with cast iron funnel and wire-mesh, with protection pipe of 32 mm dia light grade galvanized steel tubing upto 7.5 meters length for drawing earthlead including common salt, charcol , bentonite in alternate layers etc all in around of earthing pipe of 600mm dia, complete all as shown in EP number 2 of SSR Part-1 including testing on completion and including taking down old U/S earthing & testing complete all as specified and as directed.
5
-
-
... More
Materials and labour for earthing complete with galvanized steel pipe electrode 40mm bore, medium grade, 3.5 meters length, buried directly and preferably vertically in ground with top edge not less than 1.25 meters below ground level connected with earthing lead galvanized iron wire of size 4 mm dia connected to galvanized earth pipe by means of bolts, nuts, checknuts and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanized steel tube for watering with one end fix with cast iron funnel and wire-mesh, with protection pipe of 32 mm dia light grade galvanized steel tubing upto 7.5 meters length for drawing earthlead including common salt, charcol , bentonite in alternate layers etc all in around of earthing pipe of 600mm dia, complete all as shown in EP number 2 of SSR Part-1 including testing on completion and including taking down old U/S earthing & testing complete all as specified and as directed.
10
-
-
... More
Materials and labour for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed.
500
-
-
... More
Supply and fixing thermoplastic polycarbonate cable junction box having protection IP 66 "dust proof, acid resistant, shock proof, fire retardent self extinguisher" for outside installation with knockout entry for cable of size 16 sqmm and 155x155x100 mm with terminals, brackets for street light pole mounting and providing of one 6A MCB SP all as specified and as directed.
30
-
-
... More
Supply and fixing thermoplastic polycarbonate cable junstion box having protection IP 66 "dust proof, acid resistant, shock proof, fire retardent self extinguisher" for outside installation with knockout entry for cable of size 16 sqmm and 295x195x100 mm with terminals, brackets for street light pole mounting and providing of one 6A MCB SP all as specified and as directed.
30
-
-
... More
Materials and labour for painting old painted LT Panel/feeder pillar by two coats of synthetic enamel paint after preparation of surfaces complete all as specified and as directed.
10
-
-
... More
Servicing of LT Panel after shut down and removing all dust particles and proper layout of LT panel wlth gland packing including 2.5 sqmm copper single core copper cable including repairing/replacing door hinges/door lock etc amd for necessary connections complete all as specified and directed
9
-
-
... More
Materials and labour for Preparation of metalic surface with sand paper for street light pole and other steel surface complete all as specified and as directed by Engr- in-Charge
500
-
-
... More
Materials and labour for one coat of red oxide zinc chrome primer on steel surfaces of street light pole and other steel surface complete all as specified and as directed by Engr- in-Charge
200
-
-
... More
Materials and labour for aluminium paint two coats on newly primed metalic surface of street light pole and other steel surface complete all as specified and as directed by Engr- in-Charge
500
-
-
... More
Materials and labour for two coats of Yellow/black synthetic enamel paint on metalic surface complete all as specified and as directed by Engr- in-Charge
60
-
-
... More
Materials and labour for preparation of old decorated concrete/plastered surfaces and applying two coats of Cement based paint complete all as specified and as directed by Engr- in-Charge
300
-
-
... More
Supply, installing, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shall be made of 2 mm thick SS 304 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley. Cable entry from bottom side through cable gland including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm).
Incoming :- (i) Copper busbar rating shall be minimum 600 Amps ratings and minimum width of bus bar shall not be less than 50 mm and thickness shall not be less than 10 mm (ii) MCCB 400 Amps 4 pole breaking capacity 25 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuit protection having double insulation & positive insulation-01 No.
Outgoing :-(i) MCCB 250 Amp 4 pole 01 Nos breaking capacity 25 KA, (ii) MCCB 160A - 02 Nos breaking capacity 25 KA, (iii) MCCB 125A- 02 Nos breaking capacity 25 KA, (iv) MCCB 100 A - 01 No. All MCCB shall have thermal mag protection with Icu = 100% & rated impulse withstand voltage (Vimp) 8 KV with over current & short circuit protection having double insulation & positive insulation, (v) MCB TPN 40Amps - 02 Nos
(ii) Current transformer 100/5Amps class-1 15 VA - 2 Nos, Digital Ammeter with inbuilt selector switch -02 No, Digital Voltmeter with in built selector switch -02 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-2 Set (at both incomer MCCB)
All MCCB/MCBs shall be approved make with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands. The various feeders shall be indicated by font size not less than 20 mm letters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
1
-
-
... More
Supply, installing, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shall be made of 2 mm thick SS 304 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley. Cable entry from bottom side through cable gland including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm).
Incoming :- (i) Aluminium busbar rating shall be minimum 300 Amps ratings and minimum width of bus bar shall not be less than 50 mm and thickness shall not be less than 8 mm (ii) MCCB 200 Amps 4 pole breaking capacity 25 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuit protection having double insulation & positive insulation-01 No.
Outgoing :-(i) MCCB 160 Amp 4 pole 01 Nos breaking capacity 25 KA , (ii) MCCB 125 Amps 4 pole - 01 No braking capacity 25 KA (iii) MCCB 100 Amps - 02 Nos breaking capacity 25 KA (iv) MCCB 63A - 02 Nos breaking capacity 16 KA with thermal mag protection with Icu = 100% & rated impulse withstand voltage (Vimp) 8 KV with over current & short circuit protection having double insulation & positive insulation, (ii) MCB TPN 40Amps - 02 Nos, (iii) MCB SP 20A - 04 Nos.
(ii) Current transformer 100/5Amps class-1 15 VA - 2 Nos, Digital Ammeter with inbuilt selector switch -02 No, Digital Voltmeter with in built selector switch -02 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-2 Set (at both incomer MCCB)
All MCCB/MCBs shall be approved make with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands. The various feeders shall be indicated by font size not less than 20 mm letters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
2
-
-
... More
Supply, installing, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shall be made of 2 mm thick SS 304 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley. Cable entry from bottom side through cable gland including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm).
Incoming :- (i) Aluminium busbar rating shall be minimum 100 Amps ratings and minimum width of bus bar shall not be less than 50 mm and thickness shall not be less than 8 mm (ii) MCCB 63 Amps 4 pole breaking capacity 25 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuit protection having double insulation & positive insulation-01 No.
Outgoing :-(i) MCCB 40 Amp 4 pole 01 No breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse withstand voltage (Vimp) 8 KV with over current & short circuit protection having double insulation & positive insulation, (ii) MCB TPN 40 Amps - 03 Nos, (iii) MCB SP 20A - 04 Nos. (iii) Current transformer 100/5Amps class-1 15 VA - 2 Nos, Digital Ammeter with inbuilt selector switch -02 No, Digital Voltmeter with in built selector switch -02 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-2 Set (at both incomer MCCB)
All MCCB/MCBs shall be approved make with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands. The various feeders shall be indicated by font size not less than 20 mm letters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
1
-
-
... More
Supply, installing, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shall be made of 2 mm thick SS 304 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley. Cable entry from bottom side through cable gland including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm).
Incoming :- (i) Aluminium busbar rating shall be minimum 150 Amps ratings and minimum width of bus bar shall not be less than 50 mm and thickness shall not be less than 8 mm (ii) MCCB 100 Amps 4 pole breaking capacity 25 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuit protection having double insulation & positive insulation-01 No.
Outgoing :-(i) MCCB 63 Amp 4 pole 01 No breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse withstand voltage (Vimp) 8 KV with over current & short circuit protection having double insulation & positive insulation, (ii) MCB TPN 63 Amps - 04 Nos, (iii) MCB SP 20A - 04 Nos. (iv) Astronomical timer 16 A - 01 No
(ii) Current transformer 100/5Amps class-1 15 VA - 2 Nos, Digital Ammeter with inbuilt selector switch -02 No, Digital Voltmeter with in built selector switch -02 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-2 Set (at both incomer MCCB)
All MCCB/MCBs shall be approved make with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands. The various feeders shall be indicated by font size not less than 20 mm letters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
1
-
-
... More
Taking down old servicable LT UG Cable and refixing same after making necessary repair complete all as specified and as directed by engineer-in-charge (Note: Excavation shall be paid and measured separately under relevant items).
170
-
-
... More
Taking out old bricks and relaying after cable repair work complete all as specified and as directed.
800
-
-
... More
Materials and labour for complete servicing of servo stabilizers upto 200 KVA capacity including replacement of faulty relay, rewinding of burnt motor and topping up oil complete all as specified and as directed by Engineer-in-charge. (Note: Transformer oil for topping up shall be measured and paid separately as supply only)
3
-
-
... More
Supply only transformer oil for topping up of servo stabilizers upto 200 KVA capacity all as conforming to IS-335 complete all as specified and as directed by Engineer-in-charge. (Note: Dielectric strength of transformer oil shall be minimum 45 KV r.m.s.)
50
-
-
... More
Supply and fixing bracket for street light of 40mm dia of 1.50 mtr length with 02 x clamps of existing size and shape and 04 Nut bolts inclusive of one coat of primer followed by one coat of aluminium paint with finishing complete all as specified and as directed.
5
-
-
... More
Supply and fixing in repair stainless steel 2 way Fire Brigade Inlet connection ISI marked with inbuilt Check Valve including taking down and removed from site complete all as specified and as directed.
1
-
-
... More
Supply and fixing in repair stainless steel 63 mm bore Heavy Duty Single Headed Fire Hydrant Landing valve As per IS:5290 type 'A' ISI marked with ABS Blank cap including taking down unserviceablve valve and removing from site complete all as specified and as directed.
6
-
-
... More
Supply and fixing in repair Hose reinforced rubber lined fire Pipe of Size 63 mm bore ( 15 Mtr Length ) With Both Side SS coupling ISI marked Male & Female connection type including taking down complete all as specified and as directed.
12
-
-
... More
Supply and fixing in repair Branch Pipe with SS Nozzle as per IS 903 ISI marked including taking and removing from site down complete all as specified and as directed.
6
-
-
... More
Supply and fixing in repair of Hose box made of 18 gange MS sheet 800 mm x 600mm x 250 mm with double door with 4 mm thick glasses and door fram made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete including taking out old unservicebale Hose box and removing from site compelte all on specified and directed.
5
-
-
... More
Supply and fixing in repair Hose reel Drum ( Wall Mounted) swinging type as per IS : 884 including Hose pipe Length 30 Mtr Long of Size:- 20 mm bore thermo plastic hose as per IS 12585, ISI marked with PVC ¾ “ Shutoff Nozzle (Hydraulically Crimped) including taking down and removing from site complete all as specified and as directed.
1
-
-
... More
Supply and fixing in repair PVC Shut off Nozzle Size 20 mm bore ISI marked including taking down complete all as specified and as directed and removing from site.
6
-
-
... More
Supply and fixing in repair Hose Clamp including taking down and removing from site complete all as specified and as directed.
6
-
-
... More
Supply and fixing in repair 100mm Dual Plate Check Valve :- Cast Iron Body , D.I. Doors ,Nitrile /EPDM Seat ,Stainless Steel Shaft and springs P.N. 1.6 including taking down unserviceable and removing from site complete all as specified and as directed.
1
-
-
... More
Supply & Refilling of Carbon di Oxide Fire Extinguisher 4.5 Kg each complete all as specified and as directed.
6
-
-
... More
Supply & Refilling of ABC Powder Fire Extinguisher 6 Kg Each complete all as specified and as directed.
6
-
-
... More
Supply & Refilling of D-Fire Mechanical Foam Extinguisher 9 Ltr capacity each complete all as specified and as directed.
6
-
-
... More
Supply & Refilling of Watermist base Fire Extinguisher 9 Ltr capacity each complete all as specified and as directed.
6
-
-
... More
Supply only following Items:
-
-
-
... More
Fire Extinguisher Hose Pipe ABC Type
3
-
-
... More
Fire Extinguisher Hose Pipe CO2 Type
3
-
-
... More
valve kit for Fire ExtinguisherABC Type
3
-
-
... More
Fire Extinguisher valve for foam type
3
-
-
... More
Fire Extinguisher valve for Water type
3
-
-
... More
Pressure Meter
3
-
-
... More
Hanging Clip ( Hooke ) for Fire Extinguisher
18
-
-
... More
Carbon di Oxide Fire Extinguisher 4.5 Kg each
3
-
-
... More
ABC Powder Fire Extinguisher 6 Kg Each
3
-
-
... More
D-Fire Mechanical Foam Extinguisher 9 Ltr capacity each
3
-
-
... More
Watermist base Fire Extinguisher 9 Ltr capacity each
3
-
-
... More
Labour only for Control Panel Fault Detection & Rectification by changing Necessary defective Components along with necessary copper wire, Lugs, Terminal etc. including testing complete all as specified and as directed.
Note: Spare parts will be measured and paid separately under approprite item
1
-
-
... More
Supply only following Items:
-
-
-
... More
3 Pole 32 A Power Contactor
1
-
-
... More
Thermal Overload Relay ,Relay Range 14-23 A
1
-
-
... More
Set of 3 Phase Indicating Lamps (Red Yellow & Blue )
1
-
-
... More
Push Button Assembly with auxiliary contact Block Start & Stop
1
-
-
... More
63 Amp TPN MCB 10 KA
1
-
-
... More
1 Pole 2 Way Rotary Cum Switch for Auto & Manual selection
1
-
-
... More
Single Phase Preventer
1
-
-
... More
Danfoss Make KP35 Pressure Switch
1
-
-
... More
Ball Valve 15 mm
1
-
-
... More
PVC Insulated & PVC Shethed Multi core bright Annealed bare Copper Conductor flexible Round Cables Size 1 Sq mm 2 core FRLSH
30
-
-
... More
Servicing of motor pump set of capacity 5/7.5 HP by disassembling, (i)Motor Front over and back cover part by part dismantling, Internal Coil Heat Varnish, Insulation Testing & refixing. (ii) Pump Part by part Dismantling, ThroughServicing, replacement of bearing & Gland Packing /Mechanical seal, re assembly with proper alignment complete all as specified and as directed.
1
-
-
... More
Materials and labour for re-winding of motor with superior quality copper winding wire of existing size including varnishing and drying cable jointing and repair replacement of worn at parts of motor/pump reassembling , re-installing at site and testing the same complete all as specified and as directed.
1
-
-
... More
Materials and labour for painting of motor pump set complete all as specified and as directed
1
-
-
... More
Materials and labour for painting of fire fighting water MS pipeline by red colour synthetic enamelled paint by suitable safety arrangement upto height of 20 mtrs height complete all as specified and as directed.
29
-
-
... More
Materials and labour for repairing of fire fighting alarm control panel & rectification by changing necessary defective components alongwith necessary copper wire , PCB repairing work including testing on completion complete all as specified and as directed.
1
-
-
... More
Supply and fixing in replacement fire alarm metalic body ISI marked complete all as specified and directed.
10
-
-
... More
Supply and fixing manual call point ISI marked PVC/ABS body wall mounting type including grouting of MCP on wall using 1:3:6 plaster complete all as specified and directed.
19
-
-
... More
Supply, laying, jointing & testing MS tubing heavy grade 100mm tubing medium grade with all fittings such as bends, elbow, tee, socket, reducers, unions etc as required at site laid in trenches or fixing complete with clips, wall hooks etc. complete all as specified and directed.
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%