Military Engineer Services Tender
... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Eprocure
Opening Date7 Feb 2025
Closing Date28 Feb 2025
Tender Amount₹ 43,00,000
Costs
EMD
₹ 86,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_696825_1Tender No
CWE/BKP/26 OF 2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply and fix in repairs HT bus bar with insulators as suitable for existing rating current in three phase with proper moisture proof with nuts, bolts and washer and suitable lugs with proper crimping and adequate clearance between the bus bar and earth and any fabrication as required as per site conditions by the contractor at its own cost complete all as specified and directed.
12
-
-
... More
Supply and fixing in repairs of 11 KV HT CTs( Primary and secondary) as per existing suitable ratio, whether wound ring or bar type with complete settings with relay, short circuit instrument, earthfault instrument ,metering equipment with transformer ratio adjustment with burden,accuracy and overhauling of primary injection by artificial load through CT's & secondry injection of over current earth fault relays/release on each multipule setting readjustment and testing comlete all as specified and directed.
4
-
-
... More
Supply and fix in repairs of 11 KV PT's both ( Primary and secondary) and apply multi grease for mechanical parts, inspecting HT bushing male and female and apply dry graphite conductive sealant for contacts,replaced damaged insulators and testing, and assembling, allienemts of components and testing complete all as specified and directed.
4
-
-
... More
Supply and fixin repairs of 11 KV HT contact assembly such as auxillary contactor(2 No+2NC) with burnt coil and all accessories and checking of electrical wiring system,and testing complete all as specified and directed.
1
-
-
... More
Supply and fix in repairs phase indication 'RYB' neon lamps with all connected accessories and including 9W LED lamp at inside of the VCB with electrical wiring system and testing complete all as specified and directed.
1
-
-
... More
Supply and fix in repairs tripping shaft assembly with coil and including springs,strips and connected accessories for functional requirement with electrical wiring system and testing complete all as specified and directed.
1
-
-
... More
Supply and fix in repairs closing shaft assembly with coil and including springs, close strips and connected accessories for functional requirement with electrical wiring system and testing complete all as specified and directed.
1
-
-
... More
Supply and fix in repairs vaccum interrupter bottles assembly and connected accessories for functional requirement and checking of electrical wiring system and testing complete all as specified and directed.
1
-
-
... More
Supply and fix in repairs of 11 KV numerical relay 2 o/c + E/F and connected accessories for functional requirement checking of electrical wiring system and testing complete all as specified and directed.
1
-
-
... More
S&F in repairs of 11 KV HT Ammeter,digital type with selector switch of size 96X96mm primary current should be programable all as specified and directed. Make:DIP/AE/IMP/ MECO
1
-
-
... More
Disconnected of 6.6KV electric supply from existing 2/4 pole structure and maintenance and servicing/ overhauling of existing indoor type, horizontal draw out type VCB, of rupturing capacity 250/350 MVA, current rating of 630-800 Amps by disconnected HT cable termination joints, checking and cleaning all the spare parts of 6.6 KV VCB to avoid any chance of flashing, loose connection sparking, any burning parts and to replace all nuts,bolts and washers, if found any damaged due to flashing,short circuit, moisture descaling(cleaning of joints/busbars),earth fault etc with new one anodiesed of existing size,testing and calibration of earth fault and over load relays complete after re-connection of all dismantled cables and again testing after re-charging the VCB and testing complete with satisfactorily of Engr-in-charge and the necessary spares i e as per original equipment manufactures as per site requirement and materials as under:- (Location BGTC :- BGTC old & Power House No.6 of 6.6 KV sub stn Make:- Yamuna & CG).
1
-
-
... More
All as per item No.14 above but 11 KV VCB 630 Amps complete all as specified and directed. (Location:- TCP, Nursing Mess and Power House No 2 11 KV Sub Stn)
4
-
-
... More
All as per item No.14.00 above but VCB 800 amps complete all as specified and directed (Location:- BH,DODA,RCTC, APS , CQB & Power House No.1 11 KV Sub Stn Make:- Yamuna & ABB) Note for item Nos 14 to 16: - (i) New spare parts shall be measured & paid separetly under relevent items as supply only (ii) Cost of sleeves if replaced shall be demed to be included in unit rate only (iii) Transportation requirement at site and back cost shall be included in quoted rate only
4
-
-
... More
Supply and fix and as in repairs connected items of 11 KV VCB monitor display in which circuit breaker 'open' where indication light should be " Green" colour, Breaker 'Close' indication light "Red", breaker 'auto trip' indication light "White" and breaker 'Spring charged' indication light is to be "Blue" and all connected items made serviceable and testing complete all as specified and directed.
1
-
-
... More
M&L for spray painting of vaccume circuit breaker 6.6/11 KV following capacity,indoor type with two coats of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities complete all as per specified and directed.
-
-
-
... More
(a) 6.6KV indoor type VCB 630 Amps
4
-
-
... More
(b) 6.6KV indoor type VCB 800 Amps
1
-
-
... More
(c) 11KV indoor type VCB 630 Amps
5
-
-
... More
(d) 11KV indoor type VCB 800 Amps
2
-
-
... More
Testing of dielectric strength of transformer oil of indoor type transformer, 11KV/433 volt,& filteration of transformer oil by passing through filtration machine /plant to remove moisture , impurities and for improving di-electic strength to above 60 KV for 2mm gap and including filling with new transformer oil for toping up & testing after filtration complete all as specified and directed. (Location:- TCP, BH,DODA, RCTC, APS & CQB, BGTC OLD power house & BGTC Power House No.6 11 KV Sub Stn). Note:- (i): Transformer oil shall be measured & paid separately
(ii) Contractor carry out the filtration at site by on line machine filtration shall cost quoted in unit rate only
2800
-
-
... More
Supply and toping up /replacement of new transformer oil as per IS335 with 50KV di-electric strength complete all as specified and directed .
1100
-
-
... More
Supply & fixing in repair of breather with 1450 Grams celica gel of indoor type transformers of cap 500KVA/400 KVA/315 KVA/250 KVA/200 KVA/160 KVA/100 KVA and 63 KVA, all as specified and directed.
1
-
-
... More
S&F in repairs HT volt meter,digital type with selector switch of size 96mmX96mm mm rating 0 to 15KV all as specified and directed. Make:DIP/AE/IMP/ MECO
1
-
-
... More
Repair and maintenance and servicing and overhauling of step down transformers and disconnecting of LT and HT cable carefully from Transformer and opening top cover by removing nuts, bolts and washers and all mounting accessories and conservator tanks,draining out transformer oil, and including of cleaning of oil tank with replacement of all gaskets,oil seals,servicing of tap chaging gears by cleaning and polishing tapping contact points, and dismantling of 4Nos LT bushing and 3Nos of HT bushing with studs and including necessary tools and plant for removal of sediments,carbon deposits at bottom of transformer tank, on core,on winding and cleaning/heating of slica gel in breather and replacing with new silica gel after to make up the reduced quantity and etc and new transformer oil if required for topping up and attending leakages problem and including re assembling and testing with HT megger at the presence of engineer-in- charge upto satishfatory level complete all as specified and directed. Note:- (i) Cost of sleeves if replaced shall be deemed to be included in unit rate only (ii) Any transportation requirement at site and back cost shall be included in quoted rate only.
(iii) New transformer oil and spare parts will be measured and paid separatley excluding oil seal at Ser No 26.
-
-
-
... More
(a) Transformer 63 KVA ,11KV/433Volt
1
-
-
... More
(b) Transformer 100 KVA ,11KV/433Volt
1
-
-
... More
(c) Transformer 160 KVA ,11KV/433Volt (Location- PH No-2)
1
-
-
... More
(d) Transformer 200KVA ,11KV/433Volt
3
-
-
... More
(e) Transformer 250KVA ,11KV/433Volt
1
-
-
... More
(f) Transformer 315KVA ,11KV/433Volt
3
-
-
... More
(g) Transformer 400VA ,11KV/433Volt(Location- BH,Make:- Auto Electric Gear)
3
-
-
... More
(h) Transformer 500KVA ,11KV/433Volt(Location- SUPPLY DEPOT & BGTC)
3
-
-
... More
M&L for burnt out studs and busshing with nuts of any material by providing new copper alloy stud with nut,washers and bushing on HT side and all as directed for following capacity :
-
-
-
... More
(a) Transformer 63 KVA ,11KV/433Volt (Location- Sainik Cinema Hall, Make:- Bhart Electric )
1
-
-
... More
(b) Transformer 100KVA ,11KV/433Volt (Location-TCP& Nursing Mess,Make:- Auto Electric Gear)
2
-
-
... More
(c) Transformer 200KVA ,11KV/433Volt (Location- DODA & APS,Make:- Auto Electric Gear)
2
-
-
... More
(d) Transformer 315KVA ,11KV/433Volt (Location- DODA, P/H NO.1 & CQB, Make:- Auto Electric Gear)
2
-
-
... More
(e) Transformer 400VA, 11KV/433Volt(Location- BH & RCTCMake:- Auto Electric Gear)
2
-
-
... More
All as per item No 23 but 6.6 KV Transformers complete all as specified and directed:-
-
-
-
... More
(a) Transformer 100KVA ,6.6KV/433Volt (Location-BGTC old power House, Make:- Voltamp)
1
-
-
... More
(b) Transformer 500 KVA ,6.6KV/433Volt (Location-Power House No.6, Make:- Voltamp)
1
-
-
... More
Supply & fix in repair of thermo meter(oil temperature gauge) for indoor type transformer installed at various sub stations all as specified and directed.
-
-
-
... More
(a) Transformer 63 KVA ,11KV/433Volt (Location- Sainik Cinema Hall, Make:- Bhart Electric )
1
-
-
... More
(b) Transformer 100KVA ,11KV/433Volt (Location-TCP& Nursing Mess,Make:- Auto Electric Gear)
2
-
-
... More
(c) Transformer 200KVA ,11KV/433Volt (Location- DODA & APS, Make:- Auto Electric Gear)
1
-
-
... More
(d) Transformer 315KVA ,11KV/433Volt (Location- DODA,P/H No.1 & CQB,Make:- Auto Electric Gear/ Voltamp)(As per existing location)
1
-
-
... More
(e) Transformer 400VA ,11KV/433Volt(Location- BH & RCTCMake:- Auto Electric Gear)
2
-
-
... More
Supply & fix in repair of thermometer(oil temperature gauge) for indoor type transformer installed at various sub stations all as specified and directed:-
-
-
-
... More
(a) Transformer 100KVA ,6.6KV/433Volt (Location-BGTC old power House,Make:- Voltamp) (As per existing location)
1
-
-
... More
(ii) Transformer 500 KVA ,6.6KV/433Volt (Location-Power House No.6,Make:- Voltamp)
1
-
-
... More
Material and labour for rewiring of Servo Voltage Stabilizer LT coils with copper wire/strips wound LT coil,re-strectching,rewinding the same after providing new necessary insulting packing material, by using the same old strip/wire complete of existing guage alongwith allied materials complete for upto functional requirement of capacity 250 KVA complete all as specified and drected .
1
-
-
... More
Disconnected all electrical connections and earth strip at existing Servo Voltage Stabilizer of capacity 250 KVA with all connected accessories/cables and shifting and transportation safely by hydra/ lifting vehicle and including providing suitable carrying vehicle from existing power house to MES yard and once again shifted from MES Yard to required power houses and making all electrical connections properly with earth strip etc and re connected with the shifted servo voltage Stabiliser after servicing /overhauling of transformer and testing and including providing functional accessories such as nuts,bolts,washers, lugs, sleevs etc and megger testing and complete all as specified and directed
4
-
-
... More
Materila and labour for rewinding of step down transformer HT coils with copper wire of existing guage alongwith allied materials complete for upto functional requirement of capacity 300 KVA to 400 KVA complete all as specified and directed .
1
-
-
... More
Materila and labour for rewinding of step down transformer LT coils with copper wire of existing guage alongwith allied materials complete for upto functional requirement of capacity 300 KVA to 400 KVA complete all as specified and directed.
1
-
-
... More
Material and labour for fault finding on 11 KV HT cables in trenches of any size and any length with fault detective(fault finding) machine by thumbing method and injection suitable high voltage proper fault finding equipment and all as manufactures instructions and including necessary excavation,returning filling,removing surplus soil,sand, existing bricks etc where find the cable faulty complete all as directed.
5
-
-
... More
M&L for spray painting of transformer following capacity,indoor type with Two coat of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities and all as per specified and directed:-
-
-
-
... More
(i) Transformer 63 KVA ,11KV/433Volt (Location- Sainik Cinema Hall, Make:- Bhart Electric ) (As per existing location)
1
-
-
... More
(ii) Transformer 100KVA ,11KV/433Volt (Location-TCP& Nursing Mess,Make:- Auto Electric Gear) (As per existing location)
2
-
-
... More
(iii) Transformer 200KVA ,11KV/433Volt (Location- DODA & APS,Make:- Auto Electric Gear) (As per existing location)
3
-
-
... More
(iv) Transformer 315KVA ,11KV/433Volt (Location- DODA,P/H No.1 & CQB,Make:- Auto Electric Gear & Voltamp) (As per existing location)
3
-
-
... More
(v) Transformer 400VA ,11KV/433Volt(Location- BH & RCTCMake:- Auto Electric Gear) (As per existing location)
3
-
-
... More
(vi) Transformer 500 KVA ,11KV/433Volt(Location- MAP SUP DEPOT) (As per existing location)
2
-
-
... More
(vii) Transformer 100KVA ,6.6KV/433Volt (Location-BGTC old power House,Make:- Voltamp) (As per existing location)
2
-
-
... More
(viii) Transformer 500 KVA ,6.6KV/433Volt (Location-Power House No.6,Make:- Voltamp) (As per existing location)
1
-
-
... More
Disconnected all electrical connections and earth strip at existing transformer all connected accessories/cables and shifting of 11 KV/0.433 Volts up to 100 KVA to 500 KVA capacity transformer and transportation safely by hydra/ lifting vehicle and including providing suitable carrying vehicle from existing power house to MES yard and once again shifted from MES Yard to required power houses and making all electrical connections properly with earth strip etc and re connected with the shifted transformer after servicing /overhauling of transformer and testing and including providing functional accessories such as nuts,bolts,washers, lugs, sleevs etc and megger testing and complete all as specified and directed
3
-
-
... More
Material and labour for tree branches/vegitation cutting around the 2/4 pole structure and HT lines and installations from line conductor to tree distance up to 4 mtrs and cutted wood pieces/vegitation materials disposal upto distance not exc 100 mtr at defence land location where as directed and including providing safety eqpts & cutting tools,ladders etc will be own arrangement by the contractor and complete all as specified and directed.Note:- (i) Safety measures will be fully responsible by tenderer (ii) During tree /branches/vegitation cutting any damages on OH lines/installation should be reuniform responsible fully by the tenderer with out any extracost.(iii) Approximately distance covered both side for the HT lines/installatons not exc 100 mtr measured as a one Job only
300
-
-
... More
Material and labour for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 32 X 6 mm from earth electrode to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including char coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1, including all excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value complete all as specified and directed.
8
-
-
... More
Material and labour for paintng of 4 pole structure of any type/size/length and removing from existing pole painting by using wire brush and using with emary paper and cleaning with chemical agents after cleaning of steel tubular pole and GI brackets and cross arms in two coats of red oxide primer and two coats of silver oil painting upto smooth finishining and painting to satisfactorly by engr-in-charge and painting work carryout at any height and including marking of pole numers as directed and safety eqpts & tools will be own arrangement and complete all as specified and directed.Note:- Cost of painting material is deemed to be included in quoted rate only.
12
-
-
... More
All as per item No.37 but 2 pole structure and complete all as specified and directed
8
-
-
... More
M&L for steel tubular swaged type poles 11 metrs long,pole weight approximately 175 to183 kgs, pole should be in one piece only and smooth finishing,(ISI marked) complete with all accessories such as cast iron base plate, finial taper plug,bolts, nuts, screws,washers and drilling of holes for continious GI earth wire as specified type 410 SP-53 including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black paint after preparation of surface complete all as specified and directed make as approved
6
-
-
... More
Material and labour for steel tubular pole painting of any type /size/length and removing from existing pole painting by using wire brush and using with emary paper and cleaning with chemical agents after cleaning of steel bubular pole and GI brackets and cross arms in two coats of red oxide primar and two coats of silver oil paint upto smooth finishining to satisfactorly by engr-in-charge and painting work carryout at any height, including safety eqpts & tools will be own arrangement and complete all as specified and directed
250
-
-
... More
Material and labour for PCC pole painting of any type /size/length and removing from existing pole painting by using wire brush and cleaning with with cotton waste after cleaning of PCC pole in two coats water proof cement based paint in two coats and GI brackets and cross arms in two coats of red oxide primar and two coats of silver oil paint upto smooth finishining to satisfactorly by engr-in-charge and painting work carryout at any height, including safety eqpts & tools will be own arrangement and complete all as specified and directed
25
-
-
... More
M&L for in repair cross arms, bracings, supports, clamps and back plates fabricated in structural GI sections including nuts, bolts,washers, welding, bending, fabrication, cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat of paint and including removing old unserviceable item complete all as specified and directed
4
-
-
... More
Material and labour for PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) for making good cutting portion, mass concrete, filling of foundations etc including necessary use and waste of form work complete all as specified and directed
4
-
-
... More
Material and labour in repairs for PCC (1:3:6), type C2 (using 40 mm graded stone aggregate ) for making good distrubed road surfaces including necessary use and waste of form work complete all as specified and directed
3.5
-
-
... More
Supply and fix and in repair 11 KV out door type air break gang operated device of rating 400 Amps, triple pole, vertical type,mechanically operated, mounted on HT insulators and steel channel frame with operating machanism worked from ground level with GI tubing 25 mm dia medium grade with operating handle and locking arrangement including seven lever navtal lock and providing ACSR conductor jumpers duly crimped with lugs, connecting to existing 11 KV supply and testing complete all as specified and directed.
4
-
-
... More
Supply and fix and in repair 11 KV out door type Air Break gang operated device of rating 200 Amps, triple pole, vertical type,mechanically operated, mounted on HT insulators and steel channel frame with operating machanism worked from ground level with GI tubing 25 mm dia medium grade with operating handle and locking arrangement including seven lever navtal lock and providing ACSR conductor jumpers duly crimped with lugs, connecting to existing 11 KV supply and testing complete all as specified and directed.
2
-
-
... More
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm and testing complete all as specified and directed.
8
-
-
... More
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm and testing complete all as specified and directed.
6
-
-
... More
Supply and fix cable jointing kit for 11KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm and testing complete all as specified and directed.
2
-
-
... More
Supply and fix cable jointing kit for 11KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm and testing complete all as specified and directed.
2
-
-
... More
Supply and fix cable jointing kit for 11KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm and testing complete all as specified and directed.
3
-
-
... More
Supply and fix cable jointing kit for 11KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm and testing complete all as specified and directed.
10
-
-
... More
Supply and fix cable jointing kit for 11KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm and testing complete all as specified and directed.
8
-
-
... More
Supply and fix HT 11 KV out door expulsion type lightning arrestor of transmission class having discharge capacity 65 kilo Amps including mounting accessories complete fixed on cross arms of 4 pole structure and connected with ACSR conductor & earthing connections and testing complete all as specified and directed.
2
-
-
... More
Supply, laying, in trenches/ducts/along wall /through pipes etc testing and commisssioning HT cable, XLPE insulated (Earthed),11 KV, screened PVC bedded, galvanized steel strip armoured, with stranded aluminium conductor of cross sectional area 95 sqmm,3 core conforming to IS:7098 part-II with latest ammendments up to date including suitable aluminium lugs with proper crimping and laid in trenches/ducts/wall/through pipes etc all as specified and directed. Note:-(i) Excavation,Earth work,sand cushioning,cable covers and cable protection pipes shall be measured and paid separately.) (ii) The cable shall be in one length unless otherwise directed by GE.
950
-
-
... More
M & L for brick sub class 'B' 250mm x 115mm x 0.75mm and laid in trenches as in protection of UG cable complete all as specified and directed.
6.9
-
-
... More
Material & labour for GI pipe 100mm bore "light grade" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed .
31
-
-
... More
Material & labour for GI pipe 80 mm bore "light grade" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed .
20
-
-
... More
Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and directed.
70
-
-
... More
Excavation in trenches , not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft /loose soil complete all as specified and directed.
347
-
-
... More
Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed
208.2
-
-
... More
Removing excavated soil not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed
138.8
-
-
... More
Supply and fix drop out fuse unit expulsion type for air break gange operated switch single pole mounted on and including insulators for 11KV working pressure fixed to and including MS channel with nut,bolts and washers etc, synthetic bounded fuse carrying tube complete with line taps and suitable for current carrying capacity upto 50Amps and testing complete all as specified and directed. Note:- The cable shall be in one length unless otherwise directed by GE.
4
-
-
... More
M&L for cleaning the vegitation ,grass,bushes etc inside and out side the installation perimeter incl necessary gardening works and surface excavation in all repect to maintain the installation premises in inspection mode and also cleaning of installation,panel room,verandah ,labour rest room,toilets etc and allied rooms.
(a) Neccessary tools like cutting,digging,cleaning cane brooms with bamboo handle etc for gardening purpose.
(b) The cost of all items mentioned are incl in item rate no extra payment will be paid.
70
-
-
... More
M & L for hardcore of gauge n.exc 40mm, deposited ,spread and levelled in layers n. exc 15cm thick, watered and rammed to a true surface complete all as specified and directed..
26
-
-
... More
M & L for calibration and testing of protection relays of any make or type fitted on 11 KV RMU's/CSS as per IS and code of practice to ensure NO ERROR including setting for earth fault, over current, phase over current with trip time delay in accordance to feeder load and other parameters of site, settings to ensure that fault shall not travel to nearest source feeder including minor repair, replacement of wiring etc, if required all as directed by Engr-in-Charge. Note :- (i) The setting shall be carried out by only qualified engineers. (ii) Caliberation shall be carried out as per load and site conditions to avoid any fault.
6
-
-
... More
S & F for relay of RMU upto 630Amps, complete all as specified and as directed.
1
-
-
... More
S & F for HT bushing of RMU upto 630 Amps, complete all as specified and as directed.
1
-
-
... More
Surface dressing n.exc 15 cm deep soft/loose soil complete all as specified and directed.
50
-
-
... More
M & L for brick work with subclass `B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar (1 : 6) complete all as specified and directed.
19.45
-
-
... More
Supply and spreading stone aggregate of size not exceeding 40 mm spread and leveled in layers not exceeding 15 cm to a true surface of broken stones for transformer and pole structure area all as directed
100
-
-
... More
M&L for fly ash spreading and leveling all as specified and directed.
70
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%