Military Engineer Services Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date25 Oct 2024
Closing Soon28 Nov 2024
Tender Amount₹ 15,00,000
Costs
EMD
₹ 30,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair Or Replacement Of Internal Wiring Odistribution Boards, Mcbs, Lamp Fittings, Building Security Lamps, Flame Proof Lamps, Energy Meters And Fixtures Including Repairs To Summer And Winter Appliances And Connected Works At Af Stn Under Ge Af Pan
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681394_1Tender No
C/8796/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR or REPLACEMENT OF INTERNAL WIRING ODISTRIBUTION BOARDS, MCBS, LAMP FITTINGS, BUILDING SECURITY LAMPS, FLAME PROOF LAMPS, ENERGY METERS AND FIXTURES INCLUDING REPAIRS TO SUMMER AND WINTER APPLIANCES AND CONNECTED WORKS AT AF STN UNDER GE AF PANAGAH
REPAIR or REPLACEMENT OF INTERNAL WIRING ODISTRIBUTION BOARDS, MCBS, LAMP FITTINGS, BUILDING SECURITY LAMPS, FLAME PROOF LAMPS, ENERGY METERS AND FIXTURES INCLUDING REPAIRS TO SUMMER AND WINTER APPLIANCES AND CONNECTED WORKS AT AF STN UNDER GE AF PANAGARH
REPAIR or REPLACEMENT OF INTERNAL WIRING ODISTRIBUTION BOARDS, MCBS, LAMP FITTINGS, BUILDING SECURITY LAMPS, FLAME PROOF LAMPS, ENERGY METERS AND FIXTURES INCLUDING REPAIRS TO SUMMER AND WINTER APPLIANCES AND CONNECTED WORKS AT AF STN UNDER GE AF PANAGARH
BOQ Items
Description all as per srl item No. 2 above but for one 5 pin, socket outlet, 5/6 Amps on independent board complete all as specified and directed.
40
-
-
Description all as per Serial item No 2 above but for one 3 pin, 15/16 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLSH multistraind copper cable with 2.5 sqmm single core multistraind FRLSH copper cable as earthling lead complete all as specified and directed.
40
-
-
M&L for point wiring for one light point/fan point controlled by one-one way 5/6 Amp switch with 1.5 Sqmm. (nominal area) single core FRLSH,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including non metalic rigid PVC casing and capping of 25mm with (Medium grade double locking system) complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLSH, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the diturbed surfaces compete all as specified and directed.
(Note:- (a) Three run of copper conductor of required size and one run of casing capping measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth)
(b) Quoted rates shall be deemed for casing and capping & accessories, cover plate and box of suitable module, cutting chases of wall etc. and making good disturbed wall.)
160
-
-
Description all as per srl item No. 6 above but for one 5 pin, socket outlet, 5/6 Amps on same board with other switches complete all as specified and directed.
40
-
-
Description all as per srl item No. 6 above but for one 5 pin, socket outlet, 5/6 Amps on independent board complete all as specified and directed.
50
-
-
Description all as per Serial item No 6 above but for one 3 pin, 15/16 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLSH multistrand copper cable with 2.5 sqmm single core multistraind FRLSH copper cable as earthling lead complete all as specified and directed.
60
-
-
M&L for Switch piano, flush type single pole, one way, 5/6 Amp, 240 volts complete all as specified and directed.
225
-
-
All as per Srl Item No. 10.00 here-in-before but refixing only for serviceable piano switch of 5/6 Amps obtained from item No 01 above.
50
-
-
S&F for switch socket combination 2 in 1, 5 pin, 5/6 Amp flush type complete all as specified and directed.
70
-
-
All as per Srl Item No. 12.00 here-in-before but refixing only for serviceable switch socket combination of 5/6 Amp obtained from item No 01 above.
20
-
-
S&F for switch socket combination 2 in 1, 5 pin, 6/16 amp flush type (Universal) complete as in repair all as specified and directed.
65
-
-
All as per Srl Item No. 14.00 here-in-before but refixing only for serviceable switch socket combination of 6/16 Amps obtained from item No 01 above.
10
-
-
S&F for socket outlet 2 in 1, 5 pin, 15/16 amp flush type 240 volts complete all as specified and directed.
20
-
-
All as per Srl Item No. 16.00 here-in-before but refixing only for serviceable socket outlet of 15/16 Amps obtained from item No 01 above.
5
-
-
S&F for socket outlet 2 in 1, 3 pin, 5/6 amp flush type 240 volts complete all as specified and directed.
20
-
-
All as per Srl Item No. 18.00 here-in-before but refixing only for serviceable socket outlet for 5/6 Amps obtained from item No 01 above.
20
-
-
M&L for Switch piano, flush type single pole, one way, 15/16 Amp, 240 volts complete all as specified and directed.
20
-
-
All as per Srl Item No. 20.00 here-in-before but refixing only for serviceable piano switch of 15/16 Amp obtained from item No 01 above.
5
-
-
S&F for socket modular type 6 Amps , 2/3 pin combined, 240 volts, with two module matching with existing plate complete all as specified and directed.
20
-
-
All as per Srl Item No. 22.00 here-in-before but refixing only for serviceable socket modular type of 6 Amp obtained from item No 01 above.
5
-
-
S&F for socket modular type 6/16 Amps , 2/3 pin combined, 240 volts, with two module matching with existing plate complete all as specified and directed.
20
-
-
All as per Srl Item No. 24.00 here-in-before but refixing only for serviceable socket modular type of 6/16 Amps obtained from item No 01 above.
5
-
-
S&F for switch modular type one way, 10 Amps 240 volts, with one module matching with existing plate complete all as specified and directed.
20
-
-
All as per Srl Item No. 26.00 here-in-before but refixing only for serviceable switch modular type of 10 Amps obtained from item No 01 above.
5
-
-
S&F for switch modular type one way 16 Amps 240 volts, with one module matching with existing plate complete all as specified and directed.
20
-
-
All as per Srl Item No. 28.00 here-in-before but refixing only for serviceable switch modular type of 16 Amps obtained from item No 01 above.
5
-
-
S&F for modular fan regulator stepped type, 120 watts, two module matching with existing plate complete as in repair all as specified and directed.
5
-
-
S&F for ceiling rose 3 phase, PVC/polycarbonate isolated body surface bakelite 2 to 3 terminals fixed to wall/ceiling complete all as specified and directed.
50
-
-
All as per Srl Item No. 31.00 here-in-before but refixing only for serviceable ceiling rose obtained from item No 01 above.
160
-
-
M&L for Ceiling fan regulator electronic, stepped type, hum free suitable to control speed of fan from 0 to 100% rotary type five step 240 volts AC complete all as specified and directed.
60
-
-
All as per Srl Item No. 33.00 here-in-before but refixing only for serviceable ceiling fan regulator stepped type electronic obtained from item No 01 above.
20
-
-
S &F of bell push button, flush type, 5 Amp complete as in repair all as specified and directed.
15
-
-
S &F of call bell ding dong type SP, 220/240V, surface type complete as in repair all as specified and directed.
15
-
-
M&L for sub main wiring (Concealed ) complete with 02 run of 4 sqmm, single core, copper conductor cable 1100 volts grade, FRLSH type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including concealed PVC conduit of size 25mm dia or above (medium grade) as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 4 sqmm single core, copper conductor cable 1100 volts grade, FRLSH type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items of any types complete all as specified and directed.
(Note : - (a) 02 run of 4 sqmm single core copper conductor cable and 01 run of 4 sqmm single core copper conductor and 01 run of PVC conduit and accessories shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
(b) Quoted rates shall be deemed to be inclueded for copper conductor cable, conduit & accessories and cutting, chasing, penning for concealed submain wiring n. exc 10 cm girth in brick wall/ concrete surfaces including making good the disturbed surfaces where required and pointing in cement mortar (1:3) with necessary matching existing colour duly putting etc. complete as directed.)
50
-
-
M&L for sub main wiring (Concealed) complete with 02 run of 6 sqmm, single core, copper conductor cable 1100 volts grade, FRLSH type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including concealed PVC conduit of size 32mm dia or above (medium grade) as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 6 sqmm single core, copper conductor cable 1100 volts grade, FRLSH type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items of any types complete all as specified and directed.
(Note : - (a) 02 run of 6 sqmm single core copper conductor cable and 01 run of 6 sqmm single core copper conductor and 01 run of PVC conduit and accessories shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
(b) Quoted rates shall be deemed to be inclueded for copper conductor cable, conduit & accessories and cutting, chasing, penning for concealed submain wiring n. exc 10 cm girth in brick wall/ concrete surfaces including making good the disturbed surfaces where required and pointing in cement mortar (1:3) with necessary matching existing colour duly putting etc. complete as directed.)
20
-
-
M&L for sub main wiring complete with 2 run of 4 sqmm, single core, copper conductor cable 1100 volts grade, FRLSH type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through in and including PVC casing and caping of size 25mm width (medium grage of double locking system) or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 4 sqmm single core, copper conductor cable 1100 volts grade, FRLSH type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items complete all as specified and directed.
(Note : - (a) 02 run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable and 01 run of PVC casing and caping with accessories shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth
(b) Quoted rates shall be deemed to be included for copper conductor cable, casing caping with accessories etc. and making good disturbed wall).
70
-
-
M&L for sub main wiring complete with 2 run of 6 sqmm, single core, copper conductor cable 1100 volts grade, FRLSH type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through in and including PVC casing and caping of size 25mm width (medium grage of double locking system) or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 6 sqmm single core, copper conductor cable 1100 volts grade, FRLSH type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items complete all as specified and directed.
(Note : - (a) 02 run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable and 01 run of PVC casing and caping with accessories shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth
(b) Quoted rates shall be deemed to be included for copper conductor cable, casing caping with accessories etc. and making good disturbed wall).
20
-
-
M&L for 40mm dia security light brackte made out of galvanized iron tubing (medium grade) of 1.5mtr long with complete all fittings such as nuts & bolts, washers as required, welding and flanges etc, fixed on steel tubular pole/PCC poles including taking down of old unserviceable bracket complete all as specified and directed.
10
-
-
S&F for LED building security luminaire fitting 25 watts, made in aluminium PDC housing with eppoxy power coated dark graphite grey colour finish, toughened glass cover cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including twin core 0.5 sqmm copper conductor cable from connector to fitting and after taking down old unserviceable light fittings of any type complete all as specified and directed. (Note: Material required for safety harness, ladder and T&P etc will be provided by the contractor without any extra cost).
(Make: Havells, Cat No. ENDURASUNBEAMSL25WLED757SASYBOPC or Crompton, Cat No. TRP-415-25-57-SL-LM-NBK or equivalent in Philips)
10
-
-
M&L for LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height complete as in repair all as specified and directed. (Note: Material required for safety harness, ladder and T&P etc will be provided by the contractor without any extra cost).
(Make: Havells, Cat No. LUMILINENXTBS20WLED865SPCWH or Crompton, Cat No. TCS-104-20-65-SL-DP-NWH or equivalent in Philips)
100
-
-
All as per Srl Item No. 43.00 here-in-before but refixing only for serviceable LED tube light fittins of 20 watts obtained from item No 01 above.
19
-
-
M&L for LED Tube light fitting, complete with 1x 20 watts, 220V, AC CCT 6500K, smart extruded with driver, holder and including LED tube light connection Aluminium LED pattern (4ft) with higher effect complete. Microwave sensor to save more energy. Reduce the light intensity by 70% during non occupancy with three code flexible copper conductor cable suitable size from ceiling rose and necessary fixing arrangement at any height complete as in repair all as specified and directed. (Note: Material required for safety harness, ladder and T&P etc will be provided by the contractor without any extra cost).
(Make: Havells, Cat No. LUMILINEPLUSNEOBS20WLED865SPCSSIND or Crompton, Cat No. CCS-103-20-65-SL-DP-NWH or equivalent in Philips)
10
-
-
S&F for High efficacy 2'x2' recess LED flat panel light fittings 36W LED 6000K edge-lit luminaire with in and including LED lamp suitable for armstrong/grid ceiling complete for low ceiling applications complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete as in repair all as specified and directed. (Make: Havells, Cat No. VENUSTREND2X2PLR36WLED865SWH or Crompton, Cat No. TCR-145-36-65-SL-NWH or equivalent in Philips)
2
-
-
M&L for 15 Watt LED recess/surface mounting 3000k/6000k light fitting LED backlit round shape down lighter with high effcient LEDs & glate free opal diffuser IP20, internally prewired, 230 V, complete with all accessories such as electronic driver, connector block etc and necessary fixing arrangement at any height and removing old unserviceable light fittings with all connected accessories complete all as specified and directed. (Note: Material required for safety harness, ladder and T&P etc will be provided by the contractor without any extra cost).
(Make: Havells, Cat No. EDGEPRONEORDDLR15WLED865S or Crompton, Cat No. CDR-205-15-57-SL-NWH or equivalent in Philips)
45
-
-
All as per Srl Item No. 47.00 here-in-before but refixing only for serviceale LED light fittings of 15 Watt obtained from item No 01 above.
8
-
-
M&L for 36 Watt LED recess mounting 3000k/6000k light fitting LED backlit square down lighter with high effcient LEDs with sensor & glate free opal diffuser IP20, internally prewired, 230 V, complete with all accessories such as electronic driver, connector block etc and necessary fixing arrangement at any height and removing old unserviceable light fittings with all connected accessories complete all as specified and directed. (Note: Material required for safety harness, ladder and T&P etc will be provided by the contractor without any extra cost).
(Make: Havells, Cat No. VENUSNEOHE2X2R36WLED840PIRSENSOR or Crompton, Cat No. LCTLRNM-36-FO-CDL or equivalent in Philips)
11
-
-
S&F of LED driver suitable for 600mmX600mm recessed LED light fitting complete as in repair all as specified and directed.
20
-
-
M&L for sheet metal enclosure MCB distribution board, double door (metal) single pole and neutral with IP-30 and IK 09 protection single phase 240 volts 2 way, including suitable size copper bus bar of 100 amp and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:- MCBs will be measured separately.)
2
-
-
M&L for sheet metal enclosure MCB distribution board, double door (metal) single pole and neutral with IP-30 and IK 09 protection single phase 240 volts 4 way, including suitable size copper bus bar of 100 amp and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:- MCBs will be measured separately.)
6
-
-
M&L for sheet metal enclosure MCB distribution board, double door (metal) single pole and neutral with IP-30 and IK 09 protection single phase 240 volts 8 way, including suitable size copper bus bar of 100 amp and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:- MCBs will be measured separately.)
6
-
-
S&F for factory made sheet metal enclosure, double door (metal), 415 volts, AC, TPN distribution board 4 way painted with epoxy based powder coated suitable for mounting MCB complete with including 200 Amps rated copper busbar, neutral bar, earth bar, conneting cable links with and including top bottom removeable gland plate complewte with IP 43 protection complete all as specified and directed. (Note:- MCBs will be measured separately.)
2
-
-
S&F for factory made sheet metal enclosure, double door(metal), 415 volts, AC, TPN vertical distribution board 12 way painted with epoxy based powder coated suitable for mounting MCCB complete with including 200 Amps rated copper busbar, neutral bar, earth bar, conneting cable links with and including top bottom removeable gland plate complewte with IP 43 protection complete as in repair all as specified and directed. (Note:- MCCBs will be measured separately.)
2
-
-
M&L for MCCB, FP, 415 volts, 100 Amp with ruptring capacity 10 KA, 50 Hz, 3 Phase including providing thimble for out going cables complete as in repair all as specified and directed.
2
-
-
M&L for MCB, SPN, 240 volts, 5-32 amps with rupturing capacity 10 KA, 'C' curve, including providing thimble for out going cables complete all as specified and directed.
20
-
-
M&L for MCB, SP, 240 volts, 5-32 amps with rupturing capacity 10 KA, 'C' curve, including providing thimble for out going cables complete all as specified and directed.
30
-
-
M&L for MCB, SPN, 240 volts, 40-63 amps with rupturing capacity 10 KA, 'C' curve, including providing thimble for out going cables complete all as specified and directed.
5
-
-
M&L for MCB, SP, 240 volts, 40 amps with rupturing capacity 10 KA, 'B' curve, including providing thimble for out going cables complete all as specified and directed.
20
-
-
M&L for MCB, TPN/FP, 415 volts, 100 amps with rupturing capacity 10 KA, 'C' curve, including providing thimble for out going cables complete all as specified and directed.
2
-
-
S&F for MCB SPN protected power unit of capcity 16A-25A complete all as specified and as directed.
5
-
-
Taking down ceiling fan of 1200/1400 mm sweep by unscrewing nut/bolts from its position, dismantling the fan blades, down rod after disconnecting the electric connection and fixing the same to its original place in all aspects after necessary cleaning, oiling, greasing, replacement of bush, bearing, flexible copper wire of 1.00 sq mm 3 core and marking MES number as directed by Engr-in-Charge. (Note:- (a) cost of bush, bearing, flexible copper wire of 1.00 sq mm 3 core and fixing charges for spare parts shall deemed to be included in this item.
(b) Necessary repair works and servicing done in MES store yard of AGE E/M of AF Panagarh )
200
-
-
Taking down exhaust fan of 225 mm/300mm sweep by unscrewing nut/bolts from its position after disconnecting the electric connection and fixing the same to its original place in all aspects after necessary cleaning, oiling, greasing, replacement of bush, bearing, flexible copper wire of 1.00 sq mm 3 core and marking MES number as directed by Engr-in-Charge. (Note:- (a) cost of bush, bearing, flexible copper wire of 1.00 sq mm 3 core and fixing charges for spare parts shall deemed to be included in this item.
(b) Necessary repair works and servicing done in MES store yard of AGE E/M of AF Panagarh )
45
-
-
Taking down/ dismantling complete ceiling fan of size 1200 mm sweep down rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, rotor winding etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper super enamelled wire, varnishing, heating as per manufactures design and directed and re-assembling complete ceiling fan with old/new spare parts (i.e.) rubber bush of shackle and condenser housing, gun metal bushes, ball bearing, twin twisted copper cable, necessary cleaning, oiling, greasing etc complete all as specified and directed by Engineer-in-charge. (Note :- Cost of twin twisted copper cable, bush, bearing, copper super enamelled wire, varnishing etc and fixing charges for spare parts and motor winding shall deemed to be included in this item).
125
-
-
Taking down/ dismantling complete exhaust fan of size 225mm to 300mm sweep, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of exhaust fan, taking out starter, rotor winding etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper super enamelled wire, varnishing, heating as per manufactures design and directed and re-assembling complete exhaust fan with old/new spare parts (i.e.) rubber bush of shackle and condenser housing, gun metal bushes, ball bearing, twin twisted copper cable, necessary cleaning, oiling, greasing etc complete all as specified and directed by Engineer-in-charge. (Note :- Cost of twin twisted copper cable, bush, bearing, copper super enamelled wire, varnishing etc and fixing charges for spare parts and motor winding shall deemed to be included in this item).
20
-
-
S&F for 12mm dia mild steel round bar upto one meter length ceiling fan down rod (heavy duty) including taking down old unserviceable road complete all as specified and directed.
53
-
-
M&L for fan capacitor 2.5 MFD capacity including taking out old burnt capacitor complete all as specifed and directed.
270
-
-
Taking down/ dismantling of defective/rusted storage type hot water Geyser of 25/35/50 Ltr capacity from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts such as gasket of any type, nuts/bolts, clamp by unscrewing bolts and nuts, de-scaling/cleaning inner shell, servicing, gas welding as required etc. Checking defects, re-assembling and re-installing the Geyser in position, connection and including hydraulic pressure testing of HPRV and container by hand operate hydraulic pump complete.
(Note:- Cost of gas welding, nuts/bolts, clamps, shall be deemed to be included in this item and thermostate, heating element are measured and paid separately as supply only rates and fixing charges for the same shall deemed to be included in this item.)
60
-
-
S&F for safety valve/high pressure air release valve (ISI marked) of geyser complete as in repair all as specified and directed.
20
-
-
Supply only Heating element 1.5 KW (ISI marked) cup type/thread type with the provision of thermal cut out as required of geyser.
20
-
-
Supply only Heating element 2.0 KW (ISI marked) cup type/thread type with the provision of thermal cut out as required of geyser.
5
-
-
Supply only Thermostat of range 60-90 degree centigrade as required for geyser of 25/35/50 ltrs.
45
-
-
S&F for PVC flexible pipes 15mm dia (heavy duty) both end socketed 450mm to 600mm long for hot/cold water as in repair.
10
-
-
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%