Military Engineer Services Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date27 Jan 2025
Closing Soon17 Feb 2025
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply only for starting capacitor of 80 to 100 MFD for split type air conditioners upto 2 TR capacity complete all as specified and directed. (Make: Concap/Keltron/Asian/Tesla/Sarda/Siemens/Tibcon as approved)

70

-

-

... More
Supply only for running capacitor of 36 to 60 MFD for split type air conditioners complete all as specified and directed. (Make: Concap/Keltron/Asian/Tesla/Sarda/Siemens/Tibcon as approved) (Note for item No : 2 to 5:- Material of item No. 2 to 5 to be incorporated in item No. 1.00 here-in-before)

70

-

-

... More
S&F in repairs for fan motor with blade suitable for out door unit split type air conditioner up to 2 TR capacity (as per sample) complete all as specified and directed. (Make: Indfos/Whirlpool/Danfoss as approved)

22

-

-

... More
S&F in repairs for blower fan motor with blade for out door unit including capacitor, single phase, 230V, 50Hz for split type air conditioner upto 2 TR capacity (as per sample) complete all as specified and directed. (Make: Usha/AUE/Siemens/Keltron as approved)

21

-

-

... More
S&F for sealed compressor of split type air conditioner of 1.5 TR capacity including initial filling of refrigerant gas to the required pressure and testing after taking down and removing of old unserviceable compressor complete all as specified and directed. (Make : Voltas/ Hitachi/Blue Star/Carrier/ Emerson/Tecumseh as approved)

8

-

-

... More
S&F for sealed compressor of split type air conditioner of 2.0 TR capacity including initial filling of refrigerant gas to the required pressure and testing after taking down and removing of old unserviceable compressor complete all as specified and directed. (Make : Voltas/ Hitachi/Blue Star/Carrier/ Emerson/Tecumseh as approved)

5

-

-

... More
S&F for mild steel wall bracket (as per sample) suitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and making good disturbed surfaces to match with the existing after taking down old unserviceable bracket complete all as specified and directed.

25

-

-

... More
Leak testing the complete gas circulating system with dry nitrogen after evacuating and rectifying/arresting leakage by cutting, soldering, flaring work with nut, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in split type air conditioner upto 1.5TR/ 2 TR capacity and testing complete all as specified and directed. (Note: Refrigerant gas will be measured and paid separately as "Supply only".)

35

-

-

... More
Supply and topping up of refrigerant gas (R-134a/R-410a/R-407 or superior ) suitable for Refrigerators/water coolers/Deep freezers and cold room Air conditioners complete all as specified and directed. (Make: Mafron/Refron/FLORON as approved )

110

-

-

... More
Supply and topping up of refrigerant gas (R-32 ) suitable for split/window AC complete all as specified and directed. (Make: Mafron/Refron/FLORON as approved )

40

-

-

... More
Supply and topping up of refrigerant gas (R-22 ) suitable for split/window AC complete all as specified and directed. (Make: Mafron/Refron/FLORON as approved )

40

-

-

... More
Supply only universal strainer air filters cum drier suitable for upto 2 TR capacity Split Air conditioners of any make (as per sample) complete all as specified and directed.

45

-

-

... More
Repair to remote control unit (PCB board) after taking down from indoor unit of split type AC of 1.5/2.0 TR capacity and checking the electronic circuit and rectifying the defects by replacing the defective components with new ones and testing complete all as specified and directed.

38

-

-

... More
Repair to remote control unit (PCB board) after taking down from indoor/outdoor unit of split type dual inverter AC of 1.5/2.0 TR capacity and checking the electronic circuit and rectifying the defects by replacing the defective components with new ones and testing complete all as specified and directed.

20

-

-

... More
Repair to remote control unit (PCB board) after taking down from indoor/outdoor unit of split type dual inverter AC of 1.5/2.0 TR capacity replace and refix it with new one and testing complete all as specified and directed. (Make:- LG/Daikin/Haire etc as approved)

4

-

-

... More
S&F of swing motor of 1.5/2.0 TR capacity split type AC (as per sample) after taking down of old unserviceable one from AC complete all as specified and directed.

28

-

-

... More
S&F of acoustic ('U' foam) padding with all packing material for refrigerant tubing from outdoor unit to indoor unit of dia not exceeding 25mm copper pipe after taking down of old unserviceable from AC complete all as specified and directed.

500

-

-

... More
S&F in repairs of 15 mm dia PVC pipe, including bends, tees, elbows, sockets, saddles, etc for condensed water outlet complete all as specified and directed.

450

-

-

... More
S&F in repairs of 0.064" to 0.080" (inch) dia and 28" to 35" long capillary tube with strainer for the split type AC 1.5/2 TR capacity complete all as specified and directed.

28

-

-

... More
S&F in repairs of copper tube of size 10mm (3/8 inch) dia including necessary soldering, flaring work and jointing testing in between indoor to outdoor units of split type AC complete all as specified and directed. (Make:- Malasia/Camipro/Diamond/Star as approved)

90

-

-

... More
All as per item No 23.00 here-in-before but size of copper tube 12mm (1/2 inch) dia complete all as specified and directed.

100

-

-

... More
All as per item No 23.00 here-in-before but size of copper tube 6mm (1/4 inch) dia complete all as specified and directed.

95

-

-

... More
All as per item No. 23.00 here-in-before but size of copper tube 15mm (5/8 inch) dia complete all as specified and directed.

90

-

-

... More
S&F for PVC insulated, sheathed, multistranded, 1100V grade copper conductor cable of size 4 sqmm, 3 core after taking down existing unserviceable copper cable complete all as specified and directed. (Make:- Havells/R R KABEL/FINOLEX/KEI/POLYCAB)

480

-

-

... More
S&F for PVC insulated, sheathed, multistranded, 1100V grade copper conductor cable of size 2.5 sqmm, 1 core after taking down existing unserviceable copper cable complete all as specified and directed. (Make:- Havells/R R KABEL/FINOLEX/KEI/POLYCAB)

250

-

-

... More
Supply only hand remote control for split type AC of capacity 1.5/2 TR with 2 Nos batteries, 1.5 Volt of size 'AAA' (suitable for existing make) and testing complete all as specified and directed.

20

-

-

... More
Dismantling of the split type / window type air conditioner of capacity 1.5/2.0 TR complete set from the existing position and shifting the same to the new location as per direction, complete indoor and outdoor units, refrigerant tubing, MS stand, stabilizer and cable etc and testing complete all as specified and directed.

25

-

-

... More
S&F in repairs of 3 pin industrial plug top, ISI marked, suitable for industrial metal clad socket, single phase, 240 volts, 20 Amps including connection complete as all as specified and directed. (Make:Legrand/L&T/Siemens as approved)

40

-

-

... More
S&F in repairs for copper condenser coil assembly with all accessories for split type AC upto 2 TR capacity suitable to existing make/type (as per sample) and testing complete as all as specified and directed. (Make :-Zeco/Citizen/Hitech/Loyid as approved)

4

-

-

... More
Takind down old unserviceable cooling coil assembly from split type air conditioner upto 2 TR capacity supply and fixing condenser cooling coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed.

4

-

-

... More
Taking down old unserviceable 2-3 way refrigerant control valve from split air conditioner outdoor unit after evacuating of refrigrant gas and supply and fixing 2-3 way valve suitable for split type ACs of capacity upto 2TR and testing complete all as specified and directed.

14

-

-

... More
Taking down old unserviseable split type air conditioner indoor unit and deposited in store yard for safe custody and Supply and fixing indoor unit of the split type air conditioner 1.5 TR capacity with all accessories such as installation plate with screws, blower motor, swing motor, filters etc duly pre-wired including connecting to existing refrigerant piping, electrical connections, drain pipe and testing etc complete all as specified and directed. (Make: Carrier/LG/Hitachi/Blue star/ Voltas as approved)

3

-

-

... More
Taking down old unserviseable split type air conditioner outdoor unit and deposited in store yard for safe custody and Supply and fixing outdoor unit of the split type air conditioner 1.5 TR capacity and complete with all accessories such as hermetically sealed compressor and condenser unit, capacitors, relays, fan motor, duly prewired including connecting to existing refrigerant gas piping, electrical connections and testing etc complete as in repair all as specified and directed. (Make: Carrier/LG/Hitachi/Blue star/Voltas as approved)

3

-

-

... More
Supply & fixing in repairs of capacitor 35 MFD complete all as specified and directed. (Make: Asian/Keltron/Epcos/Universal/Tibcon as approved)

90

-

-

... More
Supply & fixing in repairs of capacitor 45 MFD complete all as specified and directed. (Make: Asian/Keltron/Epcos/Universal/Tibcon as approved)

125

-

-

... More
Supply & fixing in repairs of capacitor 36 MFD complete all as specified and directed. (Make: Asian/Keltron/Epcos/Universal/Tipcon as approved)

80

-

-

... More
Taking out window type air conditioner for servicing and overhauling of capacity 1.5/2.0 TR of any make/type after disconnecting of electric connection, removing dust by using blower and cleaning the condenser coil and components by using water and caustic soda and replacing the spares like relay, Capacitors , thermostat, fan motor, blades & blower and also including carrying out servicing , overhauling and charging of refrigerant gas and testing including fixing back in its original location complete all as specified and directed. (Note :- (i) Spares will be measured and paid separately as "Supply only" under relevent item. (ii) Labour charge for taking down & fixing of "Supply only" materials are deemed to be included with quoted rate)

50

-

-

... More
Supply only of starting capacitor 80 to 100, 100 to 120 MFD for window type air conditioner complete all as specified and directed. (Make : Concap/Keltron/Asian/Tesla/Sarda/Siemens/Tibcon as approved)

70

-

-

... More
Supply only of running capacitor 40/50/60 MFD for window type air conditioner complete all as specified and directed. (Make : Concap/Keltron/Asian/Tesla/Sarda/Siemens/Tibcon as approved)

120

-

-

... More
Supply only of relay contactor suitable for existing window type air conditioners upto 1.5/2 TR capacity complete all as specified and directed. (Make: LG/Samsung/Carrier/Blue Star/Hitachi as approved)

25

-

-

... More
Supply only of relay assembly No. 1622 suitable for window type air conditioners upto 1.5/2 TR capacity complete all as specified and directed. (Make: As per sample)

20

-

-

... More
Supply only contactor, AC, 230 volts ,50Hz, suitable for Window ACs upto 2.00 TR capacity complete all as specified and directed. (Make: As per sample) (Note for item No.41.00 to 45.00 :- Materials of item No.41.00 to 45.00 to be incorporated in item No.40 here-in-before)

18

-

-

... More
S&F in repairs of thermostat switch suitable for 1.5/2.0 TR window type AC complete all as specified and directed. (Make : Honey Well/Indfors/Renutrol/Siemens/Daspars as approved)

30

-

-

... More
S&F in repairs of blower fan motor with blade including capacitor, single phase 230V, 50 Hz for window type air conditioner upto 2 TR capacity complete all as sepcified and directed. (Make: Usha/AUE/Siemens/Keltron or equivalent any make with ISI marked )

17

-

-

... More
S&F in repairs of fan motor with blade suitable for window type air conditioners upto 2 TR capacity complete all as specified and directed. (Make: As per sample)

20

-

-

... More
S&F in repairs of selector switch rotary type suitable for window type AC upto 2.0 TR capacity complete all as specified and directed. (Make: Fedderlloyd/Arco/Usha/Voltas/Rotar Switch as approved)

18

-

-

... More
Replacing the corroted outer casing with base tray sheet of the window type air conditioner of capacity upto 2 TR of any type/make and supply and fix outer casing with base sheet made out of GI sheet suitable to window type air conditioner of capacity upto 2TR complete all as specified and directed.

22

-

-

... More
Leak testing the complete gas circulating system with dry nitrogen after evacuating and rectifying/arresting leakage by cutting, soldering, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in window type air conditioner upto 2TR capacity and testing complete all as specified and directed.

30

-

-

... More
S&F in repairs of over load protector suitable for window type air conditioner complete all as specified and directed. (Make: Usha/Sriram/Sarda as approved)

30

-

-

... More
S&F of sealed compressor of window type of air conditioner of 1.5 TR capacity including initial filling of refrigerant gas to the required pressure and testing including taking down old unserviceable compressor complete all as specified and directed. (Make:Hitachi/Tecumseh/Carrier/Blue star/Emerson as approved)

10

-

-

... More
S&F of sealed compressor of window type of air conditioner of 2.0 TR capacity including initial filling of refrigerant gas to the required pressure and testing including taking down old unserviceable compressor complete all as specified and directed. (Make:Hitachi/Tecumseh/Carrier/Blue star/Emerson as approved)

1

-

-

... More
Taking down remote control with 2 Nos Batteries(1.5 Volts of size 'AAA') PCB board from window type AC of 1.5/2.0 TR capacity and checking the electronic circuit and rectifying the defects by replacing the defective components with new ones and testing complete all as specified and directed.

24

-

-

... More
Taking out old unserviceable front side grill cover and supply and fix plastic or acrylic front side grill cover for window type AC upto 2.0 TR capacity of various makes etc complete all as specified and directed.

10

-

-

... More
Taking down old unserviceable condenser coil assembly from window type air conditioner upto 2.0 TR capacity & supply and fix copper condenser coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed.

4

-

-

... More
Removing old unserviceable condenser cooling coil assembly from Window type air conditioner of 1.5 TR capacity & supply and fix condenser cooling coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed.

7

-

-

... More
M&L for spray painting to window type air conditioner of any type/make with two coats of synthetic enamel paint over a coat of red oxide primer after removal of existing treatment and preparation of surfaces and including removing dents complete all as specified and directed. (Make of Paint & Primer :- Asian/Burjer/Johnson & Nekaltron/Narolac)

10

-

-

... More
Taking out water cooler for servicing and overhauling 40/80 ltrs, 40/120 ltrs, 40/160 ltrs capacity of any make/type after disconnecting of electric connection, removing dust by using blower and cleaning all the components by using water and caustic soda, checking and replacing the spares like relay, capacitors, thermostat, PVC pipes, push cock/lift cock, float valves etc and also including carrying out servicing, overhauling and charging of refrigerant gas and testing and fixing back in its original location complete all as specified and directed. (Note:- (i) Spare will be measured & paid seperately as " Supply only" under relevent item. (ii) Labour charge for taking down & fixing of "Supply only" materials are deemed to be included with quoted rate.)

70

-

-

... More
Supply only capacitor of 10-20 MFD complete all as specified and directed. (Make:Epcos/Keltron/Tibcon/Universal as approved)

15

-

-

... More
Supply only thermostat switch for water coolers any type/make complete all as specified and directed. (Note for item No. 61.00 & 62.00 :- Materials of item No. 61.00 to 62.00 to be incorporated in item No. 60.00 here-in-before)

25

-

-

... More
S&F in repairs of PVC out let drain connecting pipe of 15 mm bore with brass nuts and washers of length not exceeding 60 cm for connecting of water coolers complete all as specified and directed. (Make : As per sample)

15

-

-

... More
S&F in repairs of relay assembly suitable for water coolers of capacity complete all as specified and directed.

40

-

-

... More
Replacing the corroded portion of the water cooler & servicing capacity 40/80 ltrs, 40/120 ltrs, 40/160 ltrs capacity of any type/ make and providing the same gauge sheet in corroded portion by bending/welding, soldering and painting the replaced portion to match with existing colour and providing base support legs complete all as specified and directed.

28

-

-

... More
S&F for sealed compressor for water cooler 40/80 Litres capacity including initial filling of refrigerant gas to the required pressure and testing complete including taking down old unserviceable compressor complete all as specified and directed. (Make: Voltas/Blue Star/Tecumseh/Emerson /Usha as approved)

8

-

-

... More
S&F for sealed compressor for water cooler 60/120 Litres capacity including initial filling of refrigerant gas to the required pressure and testing complete including taking down old unserviceable compressor complete all as specified and directed. (Make: Voltas/Blue Star/Tecumseh/Emerson/Usha as approved)

1

-

-

... More
Leak testing complete by gas circulating system with dry nitrogen after evacuate and rectifying/arresting leakage by cutting, soldering, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in water cooler 40/80 ltrs, 40/120 ltrs and 80/160 ltrs cooling capacity and testing complete all as specified and directed.

35

-

-

... More
S&F of blower fan motor for water cooler upto 160 Ltrs capacity and testing including taking down old unserviceable motor complete all as specified and directed. (Make : As per sample)

18

-

-

... More
S&F in repairs push cock/lifting cock of brass chromium plated 15 mm bore self closing type with back plate for water cooler of any capacity complete all as specified and directed.

30

-

-

... More
S&F in repairs float valve assembly 15 mm dia with PVC body, polythene float suitable for water coolar complete all as specified and directed.

45

-

-

... More
Taking down old unserviceable copper condenser coil assembly from water cooler any type 20/40 to 100/150Ltrs capacity and supply and fix copper condenser coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed.

10

-

-

... More
S&F in repair of fan motor with blade including capacitor, single phase, 230V, 50Hz for water coolers of capacity 40/80 Ltr & 60/120 Ltr complete all as specified and directed. (Make: Usha/ AUE/Siemens/Keltron or equivalent as approved)

9

-

-

... More
S&F in repair of 15mm dia pillar taps, cast copper allay with capstan head, chromium plated, screwd down high pressure with or without lettered hot or cold wiht long screwed shaks and fly nuts screwed for iron pipes as complete all as specified and directed (Make:- Essco/Marc/Prayag/Hindware as approved)

38

-

-

... More
Disconnecting and taking out the old unserviceable copper tubing and Supply and fixing copper tube of size 1/2" dia complete all as specified and directed.

10

-

-

... More
M&L for spray painting to water coolers 40/80ltrs, 40/120ltrs, 40/160 ltrs of any type/make with two coats of synthetic enamel paint over one coat of red oxide primer after removal of existing treatment and preparation of surfaces and including removing dents complete all as specified and directed.

18

-

-

... More
Taking out Refrigerator for servicing and overhauling from 165 litre to 352 ltr capacity (single door/Double door type) of any make/type after disconnecting of electric connection and cleaning all the components, checking and replacing the spares like relay,capacitors, thermostat, Fused bulb and also including carrying out servicing, oiling, greasing, charging of refrigerant gas and testing complete all as specified and directed. (Note :- (i) Spares will be measured and paid separately as "Supply only" under relevent item. (ii) Refrigerant gas will be measured and paid separately as "Supply only".)

65

-

-

... More
Supply only for relay assembly suitable for refrigerators of any type of capacity 165 to 352 litres complete all as specified and directed.

26

-

-

... More
Leak testing complete by gas circulating system with dry nitrogen, evacuate and rectifying/arresting leakage by cutting, soldering, jointing of refrigerant tubing and charging of refrigerant gas to required pressure in Refrigerator upto 352 ltr capacity and testing complete all as specified and directed.

24

-

-

... More
S&F for sealed compressor of Refrigerator upto 185 litres capacity including initial filling of refrigerant gas to the required pressure and testing including taking down old unserviceable compressor complete all as specified and directed. (Make: Voltas/Kelvinator/Kirloskar/Tecumseh/Usha/Godrej as approved)

6

-

-

... More
S&F of sealed compressor of Refrigerator of 210 to 352 litres capacity including initial filling of refrigerant gas to the required pressure and testing including taking down old unserviceable compressor complete all as specified and directed. (Make: LG/Voltas/Kelvinator/Tecumseh/Kirloskar/Usha/Godrej/Videocon/Samsung as approved)

6

-

-

... More
S&F in repair of bi-metal switch for refrigerators of any type/ capacity 165 to 352 litres complete all as specified and directed. (Make:- LG/samsung/Videocon/Godrej/Whirlpool as approved)

26

-

-

... More
S&F in repairs of condenser coil suitable for refrigerators of any type of capacity 165 to 352 litres complete all as specified and directed.

20

-

-

... More
S&F in repairs of cooling coil suitable for refrigerators of any type/ capacity 165 to 352 litres complete all as specified and directed.

18

-

-

... More
S&F in repairs of fan motor with blade suitable for refrigerators of any type of capacity 165 to 352 litrescomplete all as specified and directed.

25

-

-

... More
S&F in repairs of MS refrigerator stand suitable for refrigerator of any type and any capacity complete all as specified and directed.

9

-

-

... More
S&F in repairs of capacitor of 6 to 10 MFD complete all as specified and directed. (Make:Asian/Epcos/Tibcon/Keltron as approved)

25

-

-

... More
S&F in repairs of thermostat switch for refrigerators of any capacity/ any make complete all as specified and directed.

40

-

-

... More
S&F in repairs of heating element 20 to 40 watt for refrigerators of any capacity/ any make complete all as specified and directed. (Make: Indofoss/Ranutral/Annapurna as approved)

35

-

-

... More
Taking down old unserviceable capilary copper tube of dia 0.031" (Inch) and supply and fix new capilary copper tube suitable for existing type/make/size complete all as specified and directed.

25

-

-

... More
S&F in repairs of acrylic plastic chillar tray's suitable for vegitable ice tray's for refrigerators of any capacity complete all as specified and directed. (Make : As per sample)

12

-

-

... More
Taking down old unserviceable bulb from refrigerator of any watt/capacity and supply and fix bulb as per existing type/capacity complete all as specified and directed. (Make : As per sample)

30

-

-

... More
S&F in repairs of fan motor with blade, single phase, 230V AC 50 Hz for deep freeze of any make of capacity 200 to 400 Ltr complete all as specified and as directed. (Make : As per Sample)

12

-

-

... More
S&F of anti-bacterial gasket set for refrigerators door of any capacity/ any type/ make (as per sample) complete all as specified and directed.

38

-

-

... More
Taking out Deep freezers for repairs/ servicing to Deep freezer of capacity 150 to 400 ltr of any make/type by replacing unserviceable compressor and other parts from the machine as directed including charging of Refrigerant gas after vacuuming and making system leak proof. Brazing the suction / discharge tubes where required and cleaning of Condensing unit to achieve proper cooling effect. Checking of electronic circuit of machine and repair where necessary by replacing electronic parts and changing of wirings with proper size PVC insulated wires as directed and testing complete. (Note :- Compresssor shall be measured and paid seperately under relevent item)

20

-

-

... More
Supply only capacitor of any capacity for Deep freezer of capacity 150 to 400 Ltr complete all as specified and directed by Enginner-in- Charge.

20

-

-

... More
Supply only thermostate switch suitable for Deep freezer of capacity 150 to 400 litre (Make: Indfoss/ Denfoss/Ranutal/Annapurna as approved)

8

-

-

... More
Supply only relay assembly suitable for Deep freeze complete all as specified and directed. (Make:- As per sample.) (Note for item No. 96.00 to 98.00 :- Materials of item No. 96.00 to 98.00 to be incorporated in item No. 95.00 here-in-before)

8

-

-

... More
S&F in repairs fan motor with blade, single phase, 230V AC 50 Hz for deep freeze of any make of capacity 200 to 400 Ltr (Make : As per Sample)

12

-

-

... More
S&F for sealed compressor for deep freezer 150 to 400 litre capacity including initial filling of refrigerant gas to the required pressure and testing also including taking down old unserviceable compressor complete all as specified and directed . (Make: Voltas/Blue Star/Kirloskar/Tecumseh/Usha as approved)

5

-

-

... More
Leak testing the complete gas circulating system with dry nitrogen & evacuate and rectifying/arresting leakage by cutting, soldering, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in Deep freezer upto 400 Ltrs capacity and testing complete all as specified and directed.

10

-

-

... More
Taking down voltage stabilizer any make of capacity upto 5 KVA single phase and repairing by repacing unservicable parts and refixing the same in working condition on existing location complete all as specified and directed.

45

-

-

... More
S&F for flat sleek smooth 25A motor starter for AC including cutting fixing of concealed MS 2M box with cover and finishing as complete all as specified and directed.

30

-

-

... More
S&F in repairs of concealed socket 3 pin 25A for AC including cutting fixing MS 2M box with cover plate including all other necessary items complete all as specified and directed.

30

-

-

... More
S&F of powder coated sheet metal enclosure single door 240 volts AC,SPN distribution board 2 way suitable for flush mounting with 200 Amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200 Amps, MCB SPN/DP, and MCB SP/DP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 42 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete all as specified and as directed.

18

-

-

... More
S & F in repairs of MCB SP, 6 to 32 Amps, C Curve 240 volts, 50 Hz, including making necessary incoming and out going electric connection with suitable size of copper lugs and testing complete all as specified and as directed by Engr-in-Charge.

17

-

-

... More
S & F in repairs of MCB DP 40 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs and testing complete all as specified and as directed by Engr-in-Charge.

10

-

-

... More
Attending waterleak complain of Air conditioning/other cooling appliances unit and solve the problem after dismantling and checking sloping if required re-locate indoor unit for getting slope to drain pipe, cleaning the cabinet, PVC drain pipe etc applying tape in joint and laying/sloping the drain pipe properly and fix the problem complete all as specified and directed. (Note:- If drain pipe required it will be measured and paid separately)

112

-

-

... More
Attending cooling appliances complain and solve the problem it will be consider where there is no requirement of any material rate is only for taking job card from department and fix the prob at ground and deposite the job card duly signed by user to department.

90

-

-

... More
S&F in repairs of new stainer in place of choked old one for any type of cooling appliances complete all as specified and directed.

70

-

-

... More
M&L for water, dust and direct heat proof cover of split AC outdoor unit of any description as per direction of E-in-C.

60

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.