Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 Jul 2024
Closing Date3 Sep 2024
Tender Amount₹ 38,79,000
Costs
EMD
₹ 77,580Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_655085_2Bid Award Id
ViewTender No
GE/867/TOKEN/06 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Removing excavated material (Surplus soil) to a distance not exc 50m and depositing where directed at level not exc. 1.5m above the starting point, complete all as specified and as directed.
157.69
-
-
Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches, total 23 CM, complete all as specified and as directed.
Note - for measurement purpose punned thickeness 18 CM shall be considered
130.01
-
-
S&L sub class B bricks having minimum compressive strength 75 Kg/Sqcm laid in trenches for cable protection etc, complete all as specified and as directed.
13956
-
-
M&L Cutting through existing bituminous road /PCC/floor/approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish, complete all as specified and as directed.
28
-
-
M&L for Plain cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundtion for pole including necessary form work, complete all as specified and as directed.
1.62
-
-
M&L for Plain cement concrete (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) incl necessary form work, complete all as specified and as directed.
1.5
-
-
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor laid in trench/ on wall with the help of shadel of following size as required at site size of 150 Sqmm 3.5 Core, complete all as specified and as directed.
50
-
-
All as per above item no 10 but 120 Sqmm 3.5 Core
40
-
-
All as per above item no 10 but 95 Sqmm 3.5 Core
100
-
-
All as per above item no 10 but 50 Sqmm 3.5 Core
160
-
-
All as per above item no 10 but 35 Sqmm 3.5 Core
190
-
-
All as per above item no 10 but 25 Sqmm 4 core
370
-
-
All as per above item no 10 but 16 sq mm 4 core
200
-
-
All as per above item no 10 but 10 Sqmm 4 core
400
-
-
All as per above item no 10 but 2 core 10sqmm
240
-
-
Dismantling / Taking out Unserviceable LT cables of size upto 35 sqmm any core from any position i.e ground / walls / poles / culverts etc complete with protection pipe, complete all as specified and as directed.
1750
-
-
Laying only LT under ground cable PVC/XPLE insulated PVC sheathed 1100 V grade armoured/ unarmered any type including testing commissioning of the cross sectional area 6 mm² to 150 Sq mm², 2/ 3.5/4 core, complete all as specified and as directed.
Note :- Cable will be issued under Sch 'B' free for fixing. Excavation and earthwork will be measured under respective items.
350
-
-
S&F in repair 'Tubes "light grade" galvanised iron, laid under roads/drain, fixed to poles, walls, with flat iron clamps bolts/nuts/washers of the following sizes of 50 mm dia bore, complete all as specified and as directed.
6
-
-
All as above item no 21 but 40 mm dia
35
-
-
M & L for junction box hot press moulded SMC of 295 x 195 x 100mm and outside dimention 32 with locking arrangements consisting of necessary suitable arrangements for incoming & out going cables with cable glands & having TPN Bus bar 100A amps capacity with necessary base insulator and including necessary flat iron clamps with nuts, bolts & washers, complete all as specified and as directed.
Make- Sintex Industries Ltd or equivelent make.
30
-
-
Dismantling and taking down any type of LT poles from any location, complete all as specified and as directed.
3
-
-
Supply, Install and errect in true vertical position steel tubular swaged poles in replacement complete with MS base plate of 6mm of size 300mm X300mm finial taper plug,pole cap,bolts,nuts and washers screws,pole made out of ERW MS tubing as per IS-1161 and pole shall be as per IS-2713 Part II type 410SP-31 (9.00 Mtrs Long) complete including one coat of red oxide zinc chrome primer and two coats of Aluminium paint for exposed surfaces and two coats of black bitumenous paint for portion embedded in concrete, complete all as specified and as directed.
Note: Excavation and earth work ,PCC in foundation /plinth block/coping shall be measured and paid for separately
3
-
-
Dismantling of cross arms of MS fabricated complete with all accessories viz nut, bolts, washer etc, complete all as specified and as directed.
1
-
-
Supply and fixing cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including a coat of red oxide primer one under and one finishing coat, complete all as specified and as directed.
1
-
-
Material and labour for disconnection of electric cable from pole and bringing it to ground for cutting of damaged part of cable and putting insulation tape and reconnecting the same on exising pole after taking out additional cable from loop of the cable after excavation, complete all as specified and as directed.
10
-
-
Material and labour for Load balancing of LT panel in all three phases of all outgoings, complete all as specified and as directed under:- a) Taking of load of LT panel out going cables with the help of tong testing three times in a day to assess maximum unbalance of load.
b) To disconnect the LT cables/ TC wires and reconnect the same as per the load of the MCCB to balance the circuit.
c) Take the building wise load on the panel and make the load balance at bldg end.
8
-
-
Material and labour for cleaning of panel busbars and cable termination with the help of CRC spray, dismantling the cables from connections, lubrication of hinges of panels, welding of hinges if required and reconnecting the cables after cutting of damaged cable parts and relugging complete, tapping if required, cleaning the complete panel after disconnection from main supply and taking out of loop, complete all as specified and as directed.
Note :- i) Contractor will take proper shut down of panel from Power house before starting the work.
6
-
-
Trimming of tree branches which touches the LT/HT OH lines and 2.5 Mtr away from centre line of LT/HT oh lines span not exceeding 60 Mtr distance between poles by using neccessory T&P items and depositing the tree branches/leaves at 30 Mtrs away from the site, complete all as specified and as directed.
Note -Any number of tree branches cut in one span will be measured as one lenght for payment ,
30
-
-
Restringing of existing LT overhead line including removing the existing binding wire and rebinding with new binding wire after tightning of overhead lines including disconnecting existing jumpher and connections and reconnecting after tightning of conductor incl replacement of all jumpers, complete all as specified and as directed.
Note - (a) Single wire run of conductor in LT lines shall be measured as one lenght for payment purpose.
(b) ACSR conductor will be measured and paid separately.
250
-
-
Repairing of LT panel by means of replace the hinge and locking arrangement of the existing panel, tightening the cable with bus bar by means of suitable lugs, complete all as specified and as directed.
7
-
-
Material and labour for spray painting to outdoor/Indoor type double door LT panels/Fedder pillar box incl angle iron stand by applying two coats of synthetic enamel paint over a coat of red oxide primer after cleaning the surface thouroughly with scrapper of MS sheet and angle iron stand incl cleaning of cables, wiring and other non painted parts of paint all as directed at site, complete all as specified and as directed.
15
-
-
Material and labour for replacement of old unserviceable voltmeter/ Ammeter with Panel mounted multi function three phase digital energy meter of accuracy Cl-1.0 for measuring Voltage, Current, KW, KVAR, KWH, KVAH and power factor and making the disturbed surface good by welding/riveting in MS sheet 1.6 mm thick on the hollow portion duly painted and replacement of wiring if required, complete all as specified and as directed.
Make: Schneider EM 6400 with RS 485 Port or equivalent in Siemens/L&T.
5
-
-
Material and labour for replacement of old unserviceable indicators any type with LED based indicating lamps of RYB colour incl making hole in existing panel, complete all as specified and as directed.
Make : Legrand/ABB/Siemens
6
-
-
Material and labour for replacement of old unserviceable CT of LT Panel /Feeder pillar box with CT of 100/5A ratio, 5 VA incl connecting, disconnecting and testing, complete all as specified and as directed.
4
-
-
Material and labour for replacement of old unserviceable CT of LT Panel /Feeder pillar box with CT of 160/5A ratio, 5 VA incl connecting, disconnecting and testing, complete all as specified and as directed.
2
-
-
Supply, jointing and testing staright through joint Heat shrinkable type with jointing kit suitable for LT 1100 Volt graded XLPE size 150 to 185 sqmm x 3.5 core in any situation/position, complete all as specified and as directed.
Make : Denson/Raychem/Cabseal
2
-
-
Supply, jointing and testing staright through joint Heat shrinkable type with jointing kit suitable for LT 1100 Volt graded XLPE size 70 to 120 sqmm x 3.5 core in any situation/position, complete all as specified and as directed.
Make : Denson/Raychem/Cabseal
2
-
-
Supply, jointing and testing staright through joint Heat shrinkable type with jointing kit suitable for LT 1100 Volt graded XLPE size 25 to 50 sqmm x 3.5 core in any situation/position, complete all as specified and as directed.
Make : Denson/Raychem/Cabseal
3
-
-
S & F for replacement of pin type insulator porcelain vitreous white/ brown or green including one galvanised mild steel spindle two GI washer and one GI nut 100mm height, 65mm dia for 1100 Volt grade, complete all as specified and as directed.
8
-
-
S & F for replacement of Sackle type insulator porcelain vitreous white/ brown or green including one galvanised mild steel straps of size 31 x 5 mm, washers insulator bolt of 14 mm dia and nuts complete of size 100 mm hight and 115mm dia of working pressure 1100 volts grade, complete all as specified and as directed.
10
-
-
M&L in replacement of u/s MCCB of 4 pole 400 Amps adjustable type, 415 Volts, with breaking capacity 50 KA, complete all as specified and as directed.
Make:- L&T/ Legrand/ Scheinder/ Siemens
2
-
-
M&L in replacement of u/s MCCB of 4 pole 250 Amps adjustable type, 415 Volts, with breaking capacity 36 KA, complete all as specified and as directed.
Make:- L&T/ Legrand/ Scheinder/ Siemens
2
-
-
M&L in replacement of u/s MCCB of 4 pole 200 Amps adjustable type, 415 Volts, with breaking capacity 36 KA, complete all as specified and as directed.
Make:- L&T/ Legrand/ Scheinder/ Siemens
4
-
-
M&L in replacement of u/s MCCB 3 pole 125 Amps adjustable type, 415 Volts, with breking capacity 36 KA, complete all as specified and as directed.
Make:- L&T/ Legrand/ Scheinder/ Siemens
3
-
-
M&L in replacement of u/s MCCB of 4 pole of capacity 63 to 100 Amps 415 Volts with breaking capacity 16 KA, complete all as specified and as directed.
Make:- L&T/ Legrand/ Scheinder/ Siemens
10
-
-
S&F in replacement of primary relay foe 50 KVA 3 phase, 415 v, 50 Hz servo voltage stablizer including all electric connections, complete all as specified and as directed.
1
-
-
S&F in replacement of secondary relay foe 50 KVA 3 phase, 415 v, 50 Hz servo voltage stablizer including all electric connections, complete all as specified and as directed.
1
-
-
M&L for control wiring as per existing with color coding and marking in 50 KVA, 3 phase, 415 volt with copper wire, complete all as specified and as directed.
1
-
-
M&L for preventive maintenace/periodical servicing of 50 KVA servo voltage stablizer by checking the various critical setting in mechanism, checking of oil, checking of cooling fins, conrol wirig & testing of servo votage stablizer for smooth and correct fuctioning, complete all as specified and as directed.
1
-
-
M&L for earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc, complete all as specified and as directed.(set of two) NOTE: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
24
-
-
Supply, erection, testing and commissioning of outdoor type LT Bus Bar Chamber box in replacement, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type Aluminium bus bars 400Amps capacity for looping & branch connection system .The chamber shall be painted with powder coated paint. The bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55, complete all as specified and as directed.
(a) The bus bar chamber shall be made out of 3.0mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and angle iron padastal frame 600mm high above ground level. The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation. (Note : The bus bar chamber Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 600mm height (without base frame & canopy), 600mm width and 500mm depth).
3
-
-
M&L for painting of 9 Mtr Long steel tubular LT pole , vertical complete with cross arms with one coat of aluminium paint after cleaning and preparation of surfaces of poles, cross arms, painting 30 cm wide Yellow and black strip on poles up to 1.5 mtr high above coping level and numbering of size 70mmx40mm by using stencil to the pole with black synthetic enemal paint (1st grade ), complete all as specified and as directed.
80
-
-
Routine maintenance of 62.5 KVA DG Set consisting of normal repairs with periodical routine maintenance and testing of DG set complete of following ( i,e. Engine, alternator etc under GE 867 EWS all including consumables items like cotton waste cloth kerosene oil etc. Maintenance will be carried out as and when ordered in writing by Engineer-in-Chare of maintenance schedule, complete all as specified and as directed.
Note- Accessories/spares/new engine oil required for replacement will be measured and paid separately under respective items of schedule ‘A’ as supply only (i) Change engine oil.
(ii) Changing of oil filters, fuel filters screen filters assy.
(iii)Changing of water filter.
(iv) Making up coolant.
(v) Clean alternator winding in position by forced air and internal surfaces lubricate.
(vi) Tightining of all nut bolts.
(vii) Greasing of all points.
(viii) Checking of any leaking in fuel & oil lines
1
-
-
All as per above item no 56 but 50 KVA DG Set
1
-
-
All as per above item no 56 but 40 KVA DG set
1
-
-
All as per above item no 56 but 30 KVA DG set
1
-
-
All as per above item no 56 but 25 KVA DG set
2
-
-
All as per above item no 56 but 10 KVA DG set
1
-
-
Supply only new Engine oil 15 W 20, complete all as specified and as directed. Make : HP/BP/Indian
50
-
-
Supply only fuel filter suitable for 62.5 KVA DG Set, complete all as specified and as directed.
1
-
-
Supply only fuel filter suitable for 50 KVA DG Set, complete all as specified and as directed.
1
-
-
Supply only fuel filter suitable for 40 KVA DG Set, complete all as specified and as directed.
1
-
-
Supply only fuel filter suitable for 30 KVA DG Set, complete all as specified and as directed.
1
-
-
Supply only fuel filter suitable for 25 KVA DG Set, complete all as specified and as directed.
2
-
-
Supply only fuel filter suitable for 10 KVA DG Set, complete all as specified and as directed.
1
-
-
Supply only lubricant oil filter suitable for 62.5 KVA DG Set, complete all as specified and as directed.
1
-
-
Supply only lubricant oil filter suitable for 50 KVA DG Set, complete all as specified and as directed.
1
-
-
Supply only lubricant oil filter suitable for 40 KVA DG Set, complete all as specified and as directed.
1
-
-
Supply only lubricant oil filter suitable for 30 KVA DG Set, complete all as specified and as directed.
1
-
-
Supply only lubricant oil filter suitable for 25 KVA DG Set, complete all as specified and as directed.
2
-
-
Supply only lubricant oil filter suitable for 10 KVA DG Set, complete all as specified and as directed.
1
-
-
Supply only air filter element suitable for 62.5 KVA DG Set, complete all as specified and as directed.
1
-
-
Supply only air filter element suitable for 50 KVA DG Set, complete all as specified and as directed.
1
-
-
Supply only air filter element suitable for 40 KVA DG Set, complete all as specified and as directed.
1
-
-
Supply only air filter element suitable for 30 KVA DG Set, complete all as specified and as directed.
1
-
-
Supply only air filter element suitable for 25 KVA DG Set, complete all as specified and as directed.
2
-
-
Supply only air filter element suitable for 10 KVA DG Set, complete all as specified and as directed.
1
-
-
Supply & top up water coolant in radiotor of DG set of any capacity any make, complete all as specified and as directed.
Make : TVS Girling/volvo line or of equivelent make
60
-
-
Cleaning of the fuel tank of DG sets of 62.5/ 50/40 KVA capacity after decaning the diesel, after through cleaning with kerosene oil including replacement of level indicator pipe, complete all as specified and as directed.
3
-
-
All as per item no 82 above but capacity of 30/25/10 KVA
4
-
-
M & L for cleaning/washing the radiator, complete all as specified and as directed.
7
-
-
M&L for replacement of Radiator hose Kit suitable for 50/62.5 KVA DG set, complete all as specified and as directed.
2
-
-
M&L for replacement of Fan belt suitable for 62.5/50 KVA Gen set, complete all as specified and as directed.
1
-
-
M&L for replacement of Fan belt suitable for 40/25 KVA Gen set, complete all as specified and as directed.
1
-
-
M&L for replacement of Fan blade suitable for 40/62.5 KVA Gen set, complete all as specified and as directed.
2
-
-
M&L for replacement of Dynamo 12 Volts, 35 amps as per existing in 25 KVA DG set, complete all as specified and as directed.
1
-
-
S & F for selector switch/ rottary switch as per existing, complete all as specified and as directed.
3
-
-
Supply and fix in replacement of Lid acid battery 12 volt 75 AH suitable for 50/ 40 KVA DG set, complete all as specified and as directed.
2
-
-
Supply and fix in relacement of Power contactor 4 pole 415 Volt, 100Amps Model no L&T MCX-22 including all electric cionnections as per existing, complete all as specified and as directed.
1
-
-
Supply and fix in relacement of Power contactor 4 pole 415 Volt, 160Amps Model no L&T MCX-32 including all electric cionnections as per existing, complete all as specified and as directed.
2
-
-
Supply and fix in relacement of Power contactor 4 pole 415 Volt, 63Amps Model no L&T MCX-12 including all electric cionnections as per existing, complete all as specified and as directed.
2
-
-
Supply and fix in relacement of Auxilary ontact unit 4 pole 415 Volt, 16A Model no L&T MNX-A2 including all electric cionnections as per existing, complete all as specified and as directed.
1
-
-
Supply and fix in relacement of Auxilary ontact unit 2 pole, 415 Vot, 16A Model no L&T MCX-A1 including all electric cionnections as per existing, complete all as specified and as directed.
2
-
-
Supply and fix in relacement of Auxilary ontact unit 4 pole, 415 Vot, 10A Model no L&T MCX-A2 including all electric cionnections as per existing, complete all as specified and as directed.
1
-
-
Supply and fix in relacement of Auxilary ontact unit 2 pole, 415 Vot, 10A Model no L&T MCX-A6 including all electric cionnections as per existing, complete all as specified and as directed.
1
-
-
Supply and fix in relacement of Spare coil for ontact unit 2 pole, 415 Vot, 10A Model no L&T MCX-32 including all electric cionnections as per existing, complete all as specified and as directed.
2
-
-
Supply and fix in replacement of old unserviceable CT 100/5A ratio, 5 VA, CL-1 of DG set Panel /Feeder pillar box incl connecting, disconnecting and testing, complete all as specified and as directed.
4
-
-
Supply and fix in replacement of old unserviceable epoxy ype CT 100/5A ratio, 5 VA, CL-1 of DG set Panel /Feeder pillar box incl connecting, disconnecting and testing, complete all as specified and as directed.
2
-
-
Supply and fix MCB, Tripple Pole & Neutral, 40-63 Amps, 415 volts, 50 Hz, 16kA, complete all as specified and as directed.
Make- Legrand, Siemens, Schinder, Havells.
3
-
-
Material and labour for Load balancing of LT panel connected in DG set in all three phases of all outgoings, complete all as specified and as directed under:- a) Taking of load of LT panel out going cables with the help of tong testing three times in a day to assess maximum unbalance of load.
b) To disconnect the LT cables/ TC wires and reconnect the same as per the load of the MCCB to balance the circuit.
c) Take the building wise load on the panel and make the load balance at bldg end.
4
-
-
Material and labour for Reconditioning and reconnecting of AMF panel in Various type of DG set including removing of rust particles ad corrotion/ carbon from panel connected items like power contactor, CTs, MCCB/ MCBs, complete all as specified and as directed.
3
-
-
Supply and fix in Replacement of Off load Change over switch 4 pole, 415 Volt, 100 Ams capacity including all incomming and outgoing electric connectios, complete all as specified and as directed.
2
-
-
Dismantiling the incinerator, cleaning completely all the parts and carrying out necessary repair.And re-assembling the incinerator and testing after re-assembling, complete all as specified and as directed.
1
-
-
Material and labour in replacement of burner transformer of incinerator, complete all as specified and as directed.
1
-
-
Routine maintenance of Laundry Machine 30 kg capacity, consisting of normal repairs with periodical routine maintenance and testing of Mechanical Laundry set complete of following ( Dismantiling laundry machines , cleaning completely all the parts and carrying out necessary repair, re-assembling and testing), complete all as specified and as directed.
1
-
-
All as per above item no 118 but Dryer 30 kg capacity
1
-
-
All as per above item no 118 but Extractor 15 kg capacity
1
-
-
Supply & fix in replacement of single pointed air termination Alminium rod 12mm dia and 300 mm long incl support block incl taking down u/s, complete all as specified and as directed.
8
-
-
Supply & fix in replacement of single pointed air termination Copper rod 12mm dia and 300 mm long incl support block incl taking down u/s, complete all as specified and as directed.
8
-
-
Supply and fix in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawin in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32x6mm GI strip incl taking down u/s strip any type, complete all as specified and as directed.
40
-
-
Supply & fix in replacement of aluminium strip 25mmx 3mm as a roof conductor or down conductor complete all with saddles and fixing screws for fitting the strip, complete all as specified and as directed.
80
-
-
M&L for straighting and alignment of existing aluminium strip connected as lightning condoctor in roof/ wall in any type of building, complete all as specified and as directed.
150
-
-
Supply & fix in replacement of HDPE/porceiline insulator 15 BMD type T with nut bolts / screws for fixing of copper / aluminium strips / GI strips on walls etc to the wall / floor/pole or any indicated location etc, complete all as specified and as directed.
120
-
-
Supply and fixing in replacement of test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm , drilled and screwed including 3 nos. 8mm dia 25 mm long hex. head screw, complete with suitable polycaronate box with locking arrangement, complete all as specified and as directed.
6
-
-
M&L for Reconditioning of Lightning terminal by using of required insulators and necessary screwing work in roof and refixing of air terminatin as per existing, complete all as specified and as directed.
13
-
-
M&L for Reconditioning/ recharging of existing earthing including excavation of earth work upto 1.5 mtr from ground level and removing of soil and old materials near from earthplate as a distance of 300 mm and add salt and coal in a layer of 15 mm from bottem level upto earth plate, reassembling of funnel and water pipe, returning filling of soil and fifing of eath chamber, complete all as specified and as directed.
21
-
-
Note: In case doubling/duplicancy of BOQ items , the lowest quoted rate shall be applicable for payment.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements