Military Engineer Services Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Building Construction
Eprocure
Opening Date13 Nov 2024
Closing Date4 Dec 2024
Tender Amount₹ 38,31,000
Costs
EMD
₹ 76,620Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_683750_1Tender No
8973/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of roofs, floors (other than ground floors), beams, stair cases, landing, chajja and similar suspended work complete all as specified and directed.
0.2
-
-
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed.
1
-
-
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
500
-
-
Dismantling wrought iron or mild steel work of any description etc complete all as specified and directed.
10
-
-
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed.
620
-
-
Dismantling of asbestos cement (corrugated, semi-corrugated etc.) sheets in roof coverings complete all as specified and directed.
700
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing unserviceable tiles to the low lying areas of defence land and rubbish off the premises complete all as specified and directed.
270
-
-
S&F in repairs of 15mm bore PVC connection pipe, 450mm long with 02 Nos brass Check nuts and washers complete all as specified and as directed.
2
-
-
M&L for reinforced cement concrete (1:1.5:3) (Nominal mix) type A1 (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies and in shelves complete all as specified and directed.
0.2
-
-
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
5
-
-
M&L for brick work with sub class 'B' bricks locally available best quality straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
1
-
-
S&F of floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor (overall length of cover plate 150mm) complete all as specified and directed.
4
-
-
S&F in repairs of aluminium extuded body door closer hydraulically regulated designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg as fixed complete all as specified and directed.
4
-
-
S&F of anodised (powder coating of minimum thickness 50 micron) aluminum frame (powder coated) for doors , windows, ventilators with one or more rebates (sliding & fixed type) including jointing cleat for fixing etc complete all as specified and directed.
46
-
-
S&F for anodised (powder coating of minimum thickness 50 micron) aluminium door shutters (powder coated), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. including locking arrangement, roller complete all as specified and directed.
6
-
-
S&F of anodised (powder coating of minimum thickness 50 micron) aluminium window/ventilators shutters, double leaf type without sash bar, aluminum section weighing 0.55 Kg/m, including necessary joining cleat, glazing clips, rubber neoprene packing, hinges type B-21 100 mm long (02 Nos), peg stay 150mm long (01 No), anodised aluminium snap beading, screws etc including locking arrangement, roller complete all as specified and directed.
5
-
-
M&L for TMT bars 6 to 8 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
30
-
-
Providing formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping ) and making flat, rough finished surfaces of concrete complete all as specified and directed
4
-
-
S&F in repairs of 20mm dia aluminium, powder coated (wood colour finished), single curtain rod (wall thickness not less than 1mm) including funnels etc complete all as specified and directed.
25
-
-
S&F of mild steel bracket (heavy duty), powder coated of best quality as approved suitable for fixing 20mm bore curtain rod fixed in wall complete all as specified and directed.
15
-
-
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
600
-
-
S&F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed.
100
-
-
S&F of 605mmX605mm grid Gl frame work for seamless false ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including 12mm thick Gypsum Board in ceiling fixed with screw as per manufacturers instructions for insulation/acoustic purpose of 600mmX600mm in size fixed with snap grid false ceiling frame and 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long false ceiling complete all as specified and directed.
20
-
-
S&F of false ceiling with exposed metal (PPGI) framework/ “Tee” Grid providing and fixing of suspended Tee grid false ceiling using “T” Grid System – powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40mm thick using 4mm thick non asbestos fibre cement board of size 595 x 595mm, an asbestos Free fibre cement board manufacture using high Pressure System Curing technology. T grid Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm Cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part – 3 & B. S- 476 part 4,5,6,7 & 8 should be placed in Grid module to form complete all as specified and directed.
600
-
-
S&F of 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame complete all as per specification & drawing mentioned in SSR Part-II (2020) and as directed.
450
-
-
S&F of solid PVC Wall Lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as per specification & drawing mentioned in SSR Part-II (2020) Page No. 180 and as directed.
150
-
-
S&F of rolled mild steel angle iron roof trusses (framed) and purlins, rafters crane gantries, rails, heavy brackets etc including distance pieces, cleats, angle, tee etc including necessary cutting , welding etc complete Fe-410W (Gde E-250) quality 'A' complete all as specified and directed.
1000
-
-
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, paving, floor, hard standing, sub base floor etc including finishing the cement concrete surface even and fair without using extra cement complete all as specified and directed.
93
-
-
M&L for non skid (joint free) ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:6) for laying floor finishes complete all as specified and directed.
40
-
-
Ditto-all as per Item No.32.00 here-in-before but in skirting/dado over and including a backing coat of 10mm thick cement plaster in cement mortar (1:4) complete all as specified and directed.
10
-
-
M&L for non skid (joint free) ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:6) for laying floor finishes complete all as specified and directed.
150
-
-
Ditto-all as per Item No.34.00 here-in-before but in skirting/dado over and including a backing coat of 10mm thick cement plaster in cement mortar (1:4) complete all as specified and directed.
20
-
-
M&L for glazed ceramic coloured wall tiles (vertical) 350mm x 250mm x 7mm / 450mm X 350mm X 7mm thick or equivalent set and jointed neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles as in skirting/dado/vertical wall over and including 10 mm thick cement plaster in cement mortar (1:4) complete all as specified and directed.
50
-
-
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
400
-
-
M&L for rendering 15 mm thick on fair face of brick works or concrete surfaces of walls with cement mortar (1:4) in two coats (10mm thick backing coat + 5mm thick plaster) mixed with WPC @200ml per 50 Kg of cement on 5mm thick plaster, finished the surfaces even and smooth without using extra cement complete all as specified and directed. (Note : WPC will be measured and paid separately under relevant item.)
100
-
-
M&L for applying two coats of oil emulsion distemper over a coat of alkaline resistant primer over 3mm thick white wall care putty after preparation of newly plastered surfaces of wall complete all as specified and directed.
400
-
-
M&L for complete removal of existing wall surfaces and applying two or more coats of 100% Premium acrylic emulsion paint using air less paint sprayer having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @0.90 litre/ 10 sqm using smart technique over old surfaces complete all as specified and directed.
200
-
-
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall care putty on old decorated plastered surface of wall after and including complete removal of existing treatment and preparation of surfaces complete all as specified and directed.
100
-
-
M&L for applying two coats of 100% Premium acrylic emulsion paint(using AIR-LESS PAINT SPRAYER) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over wall surfaces by using AIR-LESS PAINT PRIMER SPRAYER using smart technique including preparation/levelling of new surface of wall using manual sand papers(where reqd) of approved grade complete all as specified and as directed.
100
-
-
S&F of 5.50mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
2
-
-
S&F of 5.50mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares exceeding 0.50 sqm each pane complete all as specified and directed.
2
-
-
S&F in repairs of 15mm dia bib tap, fancy type, cast copper alloy, capstan head, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed complete all as specified and directed.
1
-
-
S&F in repairs of 15mm dia 2way bib tap with flange, cast copper alloy, capstan head, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed complete all as specified and directed.
1
-
-
S&F in repairs of 15 mm bore angular stop valve with flange, chromium plated, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
2
-
-
S&F in repairs of brass chromium plated tubular towel rail, 20mm dia, D-type, 60cm long between flanges complete all as specified and directed.
1
-
-
S&F in repairs of toilet paper holder fixed to walls with chromium plated (CP) brass screws all as specified and directed.
1
-
-
S&F in repairs of 125mm dia grating with waste hole , fancy type, chromium plated complete all as specified and directed.
1
-
-
S&F in repairs of 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia suitable for low level cistern fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete all as specified and directed.
1
-
-
S&F in repairs of vitreous china wash down water closet pan (pedestal pattern) white with 'P' or 'S' trap type(excluding flushing cistern & flush pipe) including connection to trap with 110mm PVC (SWR) connection and lip ring & to flushing pipe, anti-syphonage pipe out in with and including white seat cover etc. including making good to floor complete all as specified and directed.
1
-
-
S&F in repairs of health faucet fixed to EWC with 1mtr long easy flexible tube of 8mm dia and wall hook complete all as specified and directed.
1
-
-
S&F in repairs of soap dish, chromium plated, fixed to plugs with chromium plated brass screws complete all as specified and directed.
1
-
-
S&Fof vitreous china urinal, back or corner wall type white (flat back size of 465x355x265mm) with grating and union for discharge pipe (excluding flushing cistern, flush pipe, trap and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2) securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement including taking down old unserviceable urinal complete all as specified and directed.
1
-
-
S&F for urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (Minimum weight 60gms) complete all specified and directed.
1
-
-
S&F of 32mm bore bottle trap for wash basin with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and directed.
1
-
-
S&F in repairs of vitreous china wash basin, white, flat back, size 580 X 450 mm, excluding taps, waste pipe chain and plug and porcelain stopper but including brackets and cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
1
-
-
S&F in repairs 15mm dia pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with letter 'HOT' or 'COLD' with long screwed shanks & fly nuts, screwed for iron pipes complete all as specified and directed.
1
-
-
Taking up or down 15mm bore steel tubing including connections complete all as specified and directed.
20
-
-
Refixing of 15mm dia tubes (medium grade) galvanised iron, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including cleaning etc complete all as specified and directed.
5
-
-
S&F of 15mm dia tubes (medium grade) galvanised iron, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
15
-
-
Taking up or down 20mm bore steel tubing including connections complete all as specified and directed.
20
-
-
Refixing of 20mm dia tubes (medium grade) galvanised iron, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including cleaning etc complete all as specified and directed.
5
-
-
S&F of 20mm dia tubes (medium grade) galvanised iron, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
15
-
-
S&F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in trenches or in floor including taking down old unserviceable pipecomplete all as specified and directed.
2
-
-
S&F of 110 mm bore PVC (SWR) bends complete all as specified and directed.
2
-
-
S&F of 110 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
2
-
-
S&F of 110mm bore PVC(SWR) junction single, (single T) equal or unequal providing access door complete all as specified and directed.
2
-
-
S&F of 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
1
-
-
S&F in repairs of 75 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
2
-
-
S&F in repairs of 75 mm bore PVC (SWR) bends complete all as specified and directed.
2
-
-
S&F in repairs of 75mm bore PVC(SWR) junction single, (single T) equal or unequal providing access door complete all as specified and directed.
2
-
-
S&F in repairs of 75 mm bore PVC (SWR) vent cowl complete all as specified and directed.
1
-
-
S&F in repiars of 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
1
-
-
S&F in repairs of 600mm x 450 mm bevelled edge mirror with glass shelf assembly of selected quality glass, mounted on 6mm thick AC building board on commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
1
-
-
PART - II : (E/M WORKS) :
Excavation in trenches for laying under ground cable, foundation and erection of poles and stays in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed.
15.3
-
-
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soil all as specified and directed.
8.44
-
-
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points in soft/loose soil complete all as specified and directed.
6.86
-
-
Supply and laying of XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 10 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking down old unserviceable cable complete all as specified and directed.
(NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
80
-
-
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed.
0.54
-
-
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed. (Note: Only punned down volume of sand to be measured)
5.51
-
-
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed.
230
-
-
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of modular top cover , blanking plate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures modular accessories of suitable modules and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- (i) All necessary accessories such as modular box, top cover plate, blank plate, screws, washers etc are to be used of same make/brand only in relevant items.
(ii) Cutting & chasing of wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.)
-
-
-
One light point controlled by one switch .
127
-
-
One fan point controlled by one switch and one regulator.
29
-
-
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
40
-
-
One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
19
-
-
One exhaust fan point controlled by one switch .
1
-
-
Ditto- all as per Item No.84.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm complete all as specified and directed for the following :-
-
-
-
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on independent board.
7
-
-
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on same board.
3
-
-
Ditto -all as per Item No.84.00 here-in-before but point wiring with 4sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 4 sqmm PVC insulated multistranded flexible copper conductor FR-LSH of 3 pin, 15/16 Amps socket outlet on independent board complete all as specified and directed.
4
-
-
S&F of modular switch 10 Amps, single pole, 1 way, 1 module, 240V, AC, complete all as specified and directed.
216
-
-
S&F of modular socket shuttered type 6 Amps, 2/3 pin combined 2 module, 240 V, AC, complete all as specified and directed.
59
-
-
S&F of modular socket 6/16 Amps, 6 pin combined shutter socket, 2 module with light indication, 240 V, AC, complete all as specified and directed.
10
-
-
S&F of modular fan regulator, electronic, 360 degree rotation (0 to 4), 100 to 120 Watts, 2 module, 240Volts, AC, complete all as specified and directed.
29
-
-
S&F of angle lamp holder, insulated body with back plate with and including 10 Watt LED lamp complete all as specified and directed.
2
-
-
S&F of modular switch 16 Amps, single pole, 1 way, 1 module, 240V, AC, complete all as specified and directed.
10
-
-
S&F of ceiling rose , three terminal, PVC/polycarbonate body, complete all as specified and directed.
141
-
-
S&F of decorative box type 20 -22watt LED fittings with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos including taking down old unserviceble fittings complete all as specified and directed.
(Make : Philips Cat No. TMC501T8 and MAS LED tube PC body/ Crompto Greeves Cat No. IGP 118 T8 and LT8-20865-2/ Surya Cat No. SUB 118 T8 & SLETLDS 20 PC or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
100
-
-
S&F of recess mounting 2'x2' LED 34/36 Watt light fittings with LED lamp and required driver, slim in class LED ceiling panel with best in class aesthetic white powder coated frame blended seamlessly with ceiling layout modular ceiling grid and also can be suspended with provided kit and necessary electric connection with and including required size three coat sheathed flexible copper conductor cable from looping box to light fitting and testing complete all as specified and directed. (Make: Surya Cat No SLEDS3622R TROFFER/ Havells Cat No.PLUTOSURFACE4X1PLS34WLED857S / Philips Cat No. RC 380B LED36S 6500 G4 L60 W60 PSU ODOC or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
13
-
-
S&F of powder coated sheet metal enclosure 415 volts AC,TPN distribution board 4 way suitable for flush mounting with 100 Amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100 Amps, MCB TPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat including taking down old unserviceable DBs complete all as specified and as directed.
(Make:- Legrand cat No. 5076 80 4 way /L&T Cat No. DBTPN004GD/C&S Cat No. CSDBTPNHPCGDD04 or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
3
-
-
S&Fof powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200 Amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat including taking down old unserviceable one complete all as specified and directed.
(Make: Legrand Cat No. 5076 21 8 way /L&T Cat No.DBSPN008GD/C&S Cat No. CSDBSPNPCGDD08 or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
2
-
-
S&F of powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 12 way for flush mounting with 200 Amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat including taking down old unserviceable one complete all as specified and directed.
(Make: Legrand cat No. 5076 22 12 way /L&T Cat No. DBSPN012GD or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
2
-
-
S&F of MCB, four pole, 40 Amps to 100 Amps, 'C' Series, 415 Volts, 50Hz, complete all as specified and directed.
3
-
-
S&F of MCB, SP, 6 Amps to 32 Amps , 'B' series, 240 Volt, 10KA, 50 Hz, complete all as specified and directed
20
-
-
S&F of MCB, SP, 6 Amps to 40 Amps , 'B' series, 240 Volt, 10KA, 50 Hz, complete all as specified and directed
12
-
-
S&F of MCB, SPN, 40 Amps to 63 Amps , 'B' series, 240 Volt, 10KA, 50 Hz, complete all as specified and directed
10
-
-
S&F of flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 20 Amps, 10KA 'C' series, 240 Volts including taking down old unserviceable one complete all as specified and directed.
(Make : Legrand Cat No. 5078 11/Havells Cat No. DHDPUSN020/L&T Cat No. DBMPS220SD or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
4
-
-
S&F of 1400 RPM single phase exhaust fan motor of 300 mm sweep having , copper wound, AC, 240 Volts, 50 HZ, ISI marked complete with all standard accessories including including electric connection and testing all as specified and directed.
1
-
-
M&L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable submain wiring complete all as specified and directed .
336
-
-
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable submain wiring complete all as specified and directed .
80
-
-
M&L for sub main wiring complete with 2 run of 10 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable submain wiring complete all as specified and directed .
(Note for item No. 105 to 107 : (i)Two runs of cable with one run earth wire and PVC conduit shall be measured as one length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensured for phase/netural/earth. (iv) All surface cutting/making good for wiring/switch board/junction box/DB etc are included with unit quoted rate.)
60
-
-
M&L for earthing with glavanised steel earth plate electrode of size 600mmX600mmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old earthing complete all as specified and directed.
(Notre: Galvanised iron wire of 4mm dia upto 7.5m long including testing is deemed to be included with quoted rate).
3
-
-
M&L for 40mm bore GI pipe (Medium Grade) in any length including embedded in wall two ends duly welded MS hold fast at two ends of GI pipe and providing PCC in wall and making good disturb surfaces including taking down old unserviceable pipe complete all as specified and as directed.
24
-
-
Supply, fabricated and fixing of street light bracket made out of GI pipe 32mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 30 mm x 6 mm thick -02 Nos flat iron for fixing bracket suitable for PCC/steel tubular poles/on wall surfaces including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer including taking down old unserviceable brackets complete all as specified and directed.
12
-
-
S&F of 35/36 watt LED street light fittings IP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary connection with suitable size copper cable including taking down old unserviceable light fittings complete all as specified and directed . (Make :- SURYA CAT NO-SLE UL 36WIP66LXN / HAVELLS CAT NO. ENDURASUNDOWN SL 35W LED 765PASYBOPC / PHILIPS CAT NO. BRPO46LED36CWMRSLPSUGRor equivalent model/Cat No of make as per Appx ‘A’ as mentioned in PS here-in-after)
12
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%