Military Engineer Services Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date13 Jul 2024
Closing Date13 Jul 2024
Tender Amount₹ 48,38,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for M-25 (Design mix) using 20mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concret complete all as specified and directed.

5

-

-

... More
M&L for M-25 (Design mix) using 20mm graded stone aggregate as in chajjas complete all as specified and directed.

1

-

-

... More
M&L for M-25 (Design mix) using 20mm graded stone aggregate Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.

3

-

-

... More
Use & waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surface of concrete complete all as specified and directed.

35

-

-

... More
Use & waste Formwork to chullah hoods, chajjas, troughs and similar items including ege for fair finished surface of concreted complete all as specified and directed.

8

-

-

... More
Use & waste Formwork to sides and soffits of floor or roof beams, beam hauncings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc for fair finished surface of concrete complete all as specified and directed.

25

-

-

... More
Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete all as specified and directed.

1000

-

-

... More
M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) on walls in cement mortar (1:6), complete all as specified.

950

-

-

... More
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces finished even and smooth on walls in cement mortar (1:4) complete all as specified and directed.

300

-

-

... More
Supply only liquird water proofing compound complete all as specified.

12

-

-

... More
M&L for two coats of oil bound distemper over a coat of alkali resistant primer including preparion of new plastered surfaces of walls over a coat of wall care putty complete all as specified and directed.

950

-

-

... More
M&L for complete removal of existing treatment and applying two coats of oil bound distemper over a coat of alkali resistant primer including preparion of old plastered surfaces of walls complete all as specified and directed.

50

-

-

... More
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. (Make: M/s Apex Ultima of Asian/ Weather Coat all guard of Berger/Xtra Tough of Shalimar)

300

-

-

... More
M&L for complete removal of existing surface preparation of old plastered surface of wall for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and directed. (Make: M/s Apex Ultima of Asian/ Weather Coat all guard of Berger/Xtra Tough of Shalimar).

50

-

-

... More
M&L for Mild steel TMT bars 10 mm dia & over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.

3200

-

-

... More
All as per item No 18.00 mentioned above but 5 mm to 10 mm dia, as in stirups, spacers complete all as specified and directed

500

-

-

... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for in any position, complete all as specified and as directed.

13.5

-

-

... More
S&F rolled mild steel in plates channel (plain or chequred) square cut or notched (ordinary and counter shunk)forming holes, without any attachment of quality FE 410-W (Gde-E-250)quality-B complete all as specified and directed.

100

-

-

... More
S&F mild steel for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe-410- W(Gde- E-250) quality-B complete all as specified and directed

950

-

-

... More
M&L for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; complete all as specified and directed.

300

-

-

... More
M&L for one coats of synthetic enamel paint over & including a coat of red oxide primer over old steel surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces, completed all as specified and as directed.

250

-

-

... More
M&L for two coats of synthetic enamel paint over & including a coat of red oxide primer over new steel & iron surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified and directed.

150

-

-

... More
Dismantling (corrugated, semi corrugated) sheet in roof covering complete all as specified and directed.

575

-

-

... More
S&F Pre-painted galvalume aluminium zinc coating @150 GSM GI based corrugated steel sheet 0.5mm of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.

540

-

-

... More
S&F Pre-painted galvalume aluminum zinc coating @ 150 GSM GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in Ridges fixed with self tapping screws complete all as specified and directed.

35

-

-

... More
Taking down window chowkhats or frame not exceeding 1.5 Sqm each with shutter(s) (without taking off shutters from the frame), including removing to store complete all as specified and directed.

40

-

-

... More
Taking down chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm each with shutter(s) (without taking off shutters from the frame), including removing to store,complete all as specified and directed.

8

-

-

... More
M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50X100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardan and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made

45

-

-

... More
S&F Factory made single extruded WPC (Wood Polymer Composite) solid decorative panelled decorative flush door shutter one side plain on other side of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately)

20

-

-

... More
S&F factory made single extruded WPC (Wood Polymer Composite) wire gauzed i.e. panel will be wire mesh in lieu WPC, the wire gauze shall be warped on additional square 8mm MS Solid tube and this tube shall be welded to MS frame complete all as specified and as directed.

20

-

-

... More
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows,ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at nctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.Pbrass/ stainless steel screws, all complete as per architectural drawings and the directions of Engr-in-Chief

150

-

-

... More
S&F Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass/ stainless steel screws all.complete as per architectural drawings and the directions of Engr-in-Charge.

220

-

-

... More
S&F 4mm thick figured sheet glass ordinary quality any size and in any type of frame and glazing with oil putty (or beading) in square n.exc 0.5 Sqm in each panes complete all as specified and directed.

15

-

-

... More
S&F Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples complete all as specified and directed.

10

-

-

... More
S&F butt hinges, extruded alluminium,with mild steel hinge pin, bright polished and fixed, type 100 mm size B21 complete all as specified and directed.

48

-

-

... More
S&F 150 mm long aluminium alloy handles,fabricated type, anodised complete all as specified and directed

32

-

-

... More
S&F aluminium anodised 150 mm barrel tower bolts of extruded section complete all as specified and directed

16

-

-

... More
S&F Aluminium alloy, anodised, 300 mm long sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.

16

-

-

... More
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.

2

-

-

... More
Demolition of cement concrete as in ground floors and pavings not exceeding 15 cm thick below or above ground level (unreinforced) complete all as specified and directed.

54.05

-

-

... More
M&L for cement concrete 75mm thick 1:4:8, Type D-2 (using 40 mm graded stone aggregates) as in sub base for flooring etc complete all as specified and directed.

470

-

-

... More
M&L for Machine cut kota stone slab flooring 15 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed.

470

-

-

... More
M&L for Kota stone slab 15 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with ditto as per item 46 , over a backing coat 10mm thick in CM 1:3 complete all as specified and directed.

15

-

-

... More
Dismantling of building board of any discription fixed in any position complete all as specified and directed.

470

-

-

... More
S&F 6 mm thick non asbestos fibre cement designer building boards fixed or laid/ inserted to timber/GI / Aluminium frame work with screw fixed in ceiling flat or sloping including hangers 4 mm dia GI (up to 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60 mm long including anodised aluminium snap grid 605mm x 605 mm frame work complete all as specified.

470

-

-

... More
M&L for 75mm thick PCC 1:3:6 type C-1 (using 40mm gradede crushed stone aggregate) as in plinth protection finished even and smooth without using extra cement, incl making joints 10mm wide to the full depth of PCC at every 3 meters and at every change of direction and complete all as specified and directed.

150

-

-

... More
M&L for cement concrete 1:3:6, Type C-1 (using 20 mm graded stone aggregates) in surface channlels and drains complete all as specified and directed

3

-

-

... More
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.

150

-

-

... More
S&F Drapery rod (conduit) of dia not less than 25 mm having a corrugated virgin PVC extrusion on it & finials of approved shade with standard MS powder coated/ brackets, fixed to walls with rawl plugs and steel screws complete all as specified and directed

30

-

-

... More
M&L for Green marble work 15 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of following typesnt with admixture of pigment to match the shade of granite stone including grinding and polishing complete over 15mm thick Screed bed or backing coat for laying floor finishes in CM 1:6 complete all as specified and directed.

5

-

-

... More
Demolition of cement concrete as in ground floors and pavings not exceeding 15 cm thick below or above ground level (unreinforced) complete all as specified and directed.

15

-

-

... More
M&L for cement concrete 75mm thick 1:4:8, Type D-2 (using 40 mm graded stone aggregates) as in sub base for flooring etc complete all as specified and directed.

100

-

-

... More
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.

5

-

-

... More
M&L for Machine pressed precast pre-polished coloured concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed.

100

-

-

... More
M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed.

6

-

-

... More
E/M PORTION Taking down carefully aluminium conductor point wiring (light , fan, socket or powr) complete including fittings such as switches, ceiling rose, pendents, regulators sockets etc and removing (except those to be reused shall be kept in safe custody at the site) andmaking good disturbed surfaces of walls, floors etc tomatch with the existing completeall as specified and directed.

116

-

-

... More
M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.

88

-

-

... More
All as per item No 60.00 above but One 3 pin 5 Amps socket out let points on independent board complete all as specified and directed.

20

-

-

... More
All as per item No 60.00 above but 5 Amp socket on same board with other switches complete all as specified and directed.

6

-

-

... More
M&L for wiring for socket out let on independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor, PVC insulated unsheathed FRLH cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified.

2

-

-

... More
S&F switch piano flush type, single pole, 5/6 Amps, one way complete all as specified and directed.

70

-

-

... More
S&F switch socket combination 2 in 1 multipurpose 5 pin, (6 Amps) flush type controlled by one switch complete all as specified and directed.

20

-

-

... More
S&F socket outlets 2 in 1, 5 pin, 5/6 Amps flush type 230/240 V complete complete all as specified and directed.

6

-

-

... More
S&F switch socket combination 5 in 1, 6 pin, (5/16 Amps) flush type controlled by one switch complete all as specified and directed.

2

-

-

... More
S&F ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified.

44

-

-

... More
S&F stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified and directed.

14

-

-

... More
S&F lamp holder, PVC/polycarbomate type with back plate straoght of angle suitable for LED lamp complete all as specified and directed.

4

-

-

... More
S&F Turbo 12 watt inverter LED lamp 12 watt of capacity 220 - 240 volts, 50 Hz complete all as specified and directed

4

-

-

... More
S&F submain wiring of two single core 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable PVC insulated unsheathed 1100 volts grade drawing in and suitable size PVC conduit (ISI Marked) concealed including 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 volts grade earth wire complete all as specified and directed.

100

-

-

... More
S&F submain wiring of two single core 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable PVC insulated unsheathed 1100 volts grade drawing in and suitable size PVC conduit (ISI Marked) concealed including 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 volts grade earth wire complete all as specified and directed.

40

-

-

... More
S& wall LED security light fittings 35 watt, 230 volts, minimum lumn output 100 lumen/watt, made up ofpressure dia cast housing with prismatic polycarbonate difuser and industrial LED with secondary optic and IP-65/66 including neccessary connection complete with all accessories including connected with 3 core copper cable of suitable 1.5 sqmm size complete allas specified and directed.

12

-

-

... More
S&F LED light fitting 1 x 20 watt box type with same make LED tube rod side connection AC decorative boxype 4' long wih driver, holder including LED tube connecting up with complete all accessories andconnection from ceiling rose with twin core twisted flexible copper conductor cable withsuitable size and earthing complete all as specified and directed.

58

-

-

... More
S&F epoxy powder coated sheet metal enclosure for DBs, single door, Single pole and neutral, 8 ways, with mounting fitted with 200 Amps rated bus bar, DIN channel, neutral link and incoming contact complete all as directed.

4

-

-

... More
S&F MCB SPN 4- -63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed.

2

-

-

... More
S&F MCB SPN 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed.

2

-

-

... More
S&F MCB SP 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed.

10

-

-

... More
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion.

2

-

-

... More
S&F D clamp of strip size 25mmx6 mm with suitable washer,nuts, bolts in any shape or size as indicated or directed including making hook for hanging ceiling fan and inclusive of one primer coat ,one under coat, one finish coat of paint complete for hanging of ceiling fan all as specified and as directed.

14

-

-

... More
M&L for taking down of ceiling fans of any sweep and transportation to work shop including dismantling for repair/overhauling, oiling, greasing, vernishing including replacement of unserviceable accessories like capacitor, connector etc. After repair re-assembling fan, testing for efficient functioning including hanging it back in position and provn of 0.5 Sqmm copper flexible twin twisted cable (length not exceeding 0.5 metre) from ceiling rose to fan , complete all as specified and as directed by Engr-in-Charge.

14

-

-

... More
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.

24

-

-

... More
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.

13

-

-

... More
Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.

11

-

-

... More
Supply, laying, connecting, testing and commissioning of LT under ground cable XLPE insulated, aarmoured heavy duty electric cable with aluminium conductor , 1100 vlts grade , crsectional area 16 sqmm 2 core complete all as specified and directed Note:- (i) Excavation,sand cushioning,brick will be measured and paid separtely.

100

-

-

... More
M&L for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . Note :- Punned thickness 18 cm shall only be considered for payment

7

-

-

... More
Supply and lay in trenches fly ash bricks, for cable protection all as specified and directed by the Engr-in-Charge.

0.72

-

-

... More
S&F Pipes galvanized, 50 mm bore “light grade”, supplied and laid complete including necessary fittings such as tees, bends, elbows, sockets, reducers etc as per site requirement or specified.

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.