Military Engineer Services Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Pipe Line Project
Eprocure
Opening Date25 Jun 2024
Closing Date23 Jul 2024
Tender Amount₹ 45,50,000
Costs
EMD
₹ 91,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_661958_1Bid Award Id
ViewTender No
C/8775/2024-25/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://https://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Road cutting/removing the hard standing/cutting plinth protection of building/path for laying of pipe line of any size, complete all as specified and directed.
5
-
-
M & L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) for foundation, filling, mass concrete, making good to disturbed surfaces of road/hardstanding/plinth protection etc, complete all as specified and directed.
7
-
-
Supply and laying or fixing, three layer (inner antimicrobial, outer UV stabilized) 75mm dia, PP-R pipes SDR 11 (PN-16) confirming to IS -15801 : 2008 and having thermal stability for hot & cold water supply, including PP-R plain fittings in trenches/wall/cellings or laying in floor including taking down old unserviceable PP-R/GI pipes, complete all as specified and directed.
120
-
-
All as per item No. 6.00 here-in before but 50mm dia, complete all as specified and directed.
710
-
-
All as per item No. 6.00 here-in before but 25mm dia, complete all as specified and directed.
430
-
-
S&F in repair three layer PP-R elbow 90/45 degree (UV stabilized) confirming to IS -15801 : 2008, for 110mm dia PP-R pipes SDR 11 (PN-16), complete all as specified and directed.
4
-
-
All as per item No. 9.00 here-in before but 75mm dia, complete all as specified and directed.
13
-
-
All as per item No. 9.00 here-in before but 50mm dia, complete all as specified and directed.
20
-
-
All as per item No. 9.00 here-in before but 25mm dia, complete all as specified and directed.
39
-
-
S&F in repair three layer PP-R union 75mm dia (UV stabilized) confirming to IS -15801 : 2008, for PP-R pipes SDR 11 (PN-16), complete all as specified and directed.
11
-
-
All as per item No. 13.00 here-in before but 50mm dia, complete all as specified and directed.
24
-
-
All as per item No. 13.00 here-in before but 25mm dia, complete all as specified and directed.
25
-
-
S&F in repair three layer PP-R socket 75mm dia (UV stabilized) confirming to IS -15801 : 2008 for PPR pipes SDR 11 (PN-16), complete all as specified and directed.
12
-
-
All as per item No. 16.00 here-in before but 50mm dia, complete all as specified and directed.
22
-
-
All as per item No. 16.00 here-in before but 25mm dia, complete all as specified and directed.
30
-
-
S&F in repair three layer PP-R Female threaded Tee (brass insert) (UV stabilized) confirming to IS -15801 : 2008 for 75mm dia PP-R pipes SDR 11 (PN-16), complete all as specified and directed.
10
-
-
All as per item No. 19.00 here-in before but 50mm dia, complete all as specified and directed.
18
-
-
All as per item No. 19.00 here-in before but 25mm dia, complete all as specified and directed.
24
-
-
S&F in repair three layer PP-R Male threaded Tee (brass insert) (UV stabilized) confirming to IS -15801 : 2008 for 75mm dia PP-R pipes SDR 11 (PN-16), complete all as specified and directed.
10
-
-
All as per item No. 22.00 here-in before but 50mm dia, complete all as specified and directed.
16
-
-
All as per item No. 22.00 here-in before but 25mm dia, complete all as specified and directed.
25
-
-
S&F in repair three layer PP-R flange (core), 75mm dia (UV stabilized) confirming to IS -15801 : 2008 for PP-R pipes SDR 11 (PN-16), complete all as specified and directed.
12
-
-
S&F in repair three layer PP-R flange (ring), 75mm dia (UV stabilized) confirming to IS -15801 : 2008 for PP-R pipes SDR 11 (PN-16), complete all as specified and directed.
12
-
-
S&F 80mm dia sluice valve flanged end of class PN 1.6 (IS-14846) with brass spindle and hand wheel including necessary gasket, nuts and bolts, washer etc. including taking down old unserviceable sluice valve, complete all as specified and directed.
10
-
-
S&F 75mm bore CPVC pipe in trenches high pressure CPVC pipes shcedule 40 pipes and plain CPVC shcedule 80 fittings including all necessay fittings, like elbow, tee, socket, reducer, bushings, step over bends, end caps, end plugs, etc and with CPVC solvent cement including taking down old unserviceble CPVC/GI pipes pipes, complete all as specified and directed.
145
-
-
S&F 50mm dia CPVC pipe in trenches high pressure CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings including all necessay fittings, like elbow, tee, socket, reducer, bushings, step over bends,end caps, end plugs, etc and with CPVC solvent cement including taking down old unserviceble CPVC/GI pipes, complete all as specified and directed.
368
-
-
S&F 40mm dia CPVC pipe in trenches high pressure CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings including all necessay fittings, like elbow, tee, socket, reducer, bushings, step over bends,end caps, end plugs, etc and with CPVC solvent cement including taking down old unserviceble CPVC/GI pipes, complete all as specified and directed.
47
-
-
S&F 25mm dia CPVC pipe of size in trenches high pressure CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings including all necessay fittings, like elbow, tee, socket, reducer, bushings, step over bends, end caps, end plugs, etc and with CPVC solvent cement including taking down old unserviceble pipes, complete all as specified and directed.
442
-
-
M & L for 25mm bore steel water tubing and connection from wall /ceiling surfaces including cleaning for re-fixing or removing from site of work, complete all as specified and directed.
480
-
-
M & L for cutting existing steel tubing of size 40/50mm for alterations or additions (each cut measured), complete all as specified and directed.
53
-
-
M & L for screwing existing steel tubing of size 40/ 50mm for alterations or additions (or lengthening screw on pipe to form connector), complete all as specified and directed.
49
-
-
S&F 50mm bore gun metal gate/globe valve with iron wheel head, screwed both ends suitable for fixing with CPVC/GI pipe and taking down old unsrviceble valves, complete all as specified and directed.
23
-
-
S&F 40mm bore gun metal gate/globe valve with iron wheel head, screwed both ends suitable for fixing with CPVC/GI pipe and taking down old unsrviceble valves, complete all as specified and directed.
19
-
-
S&F 32mm bore gun metal gate/globe valve with iron wheel head, screwed both ends suitable for fixing with CPVC/GI pipe and taking down old unsrviceble valves, complete all as specified and directed.
1
-
-
S&F 25mm bore gun metal gate/globe valve with iron wheel head, screwed both ends suitable for fixing with CPVC/GI pipe and taking down old unsrviceble valves, complete all as specified and directed.
36
-
-
S&F 20mm bore gun metal gate/globe valve with iron wheel head, screwed both ends suitable for fixing with CPVC/GI pipe and taking down old unsrviceble valves, complete all as specified and directed.
13
-
-
S&F 50mm dia CPVC ball valve suitable for CPVC pipe incl necessary fittings and taking down old unserviceble vall valve, complete all as specified and directed.
7
-
-
S&F 25mm dia CPVC ball valve suitable for CPVC pipe incl necessary fittings and taking down old unserviceble vall valve, complete all as specified and directed.
18
-
-
Dismantling cross arm of MS channel or angle section etc complete and setting asidefor credit, complete all as specified and directed.
1.8
-
-
M & L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paint complete for base support frame for water tanks at roof top/ground floor, complete all as specified and directed.
1.8
-
-
Taking up or down steel tubing and connections, of size 20/25mm bore including cleaning for refixing or removal to store, complete all as specified and directed.
800
-
-
Refixing old steel tubing and connections in new or old position, 25/20mm bore pipe (walls, ceiling, floors etc.), complete all as specified and directed. (Note : Serviceable steel tube obtained from taking down shall be re-used)
310
-
-
M & L for construction of valves pit chamber of size (1200mm x1200mm x1200mm, internal), PCC (1:4:8) (using 40mm graded crushed stone aggregate) for foundation 15cm thick, 23cm thick wall in CM (1:4) 10mm thick rendering all around the brick work with 1:6 cement mortar PCC (1:2:4) type B1 coping with 20mm gradded aggregate for grouting MS frame including 3mm thick MS top sheet cover with locking arrangement including 50mm pad lock with double key arrangement, MS frame out of 40 x 40 x 5mm thick angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primers finishing coat incuding necessary exavaation in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as specified and including demolition /dismantling of existing cracked valve chamber, complete all as specified and directed.
5
-
-
S&F 50mm dia CPVC male adapter (brass threaded) suitable for fixing with gate valve or with CPVC ball valve, complete all as specified and directed.
9
-
-
S&F 40mm dia CPVC male adapter (brass threaded) suitable for fixing with gate valve or with CPVC ball valve, complete all as specified and directed.
2
-
-
S&F 25mm dia CPVC male adapter (brass threaded) suitable for fixing with gate valve or with CPVC ball valve, complete all as specified and directed.
14
-
-
S&F 50mm dia CPVC union suitable for fixing with CPVC pipe or with CPVC ball valve, complete all as specified and directed.
9
-
-
S&F 40mm dia CPVC union suitable for fixing with CPVC pipe or with CPVC ball valve, complete all as specified and directed.
2
-
-
S&F 25mm dia CPVC union suitable for fixing with CPVC pipe or with CPVC ball valve, complete all as specified and directed.
14
-
-
Restringing and tightening of ACSR conductor of any size and type maintaining stranded sag including providing aluminium binding wire, jumpers on HT/LT over head lines with jumper clip including re-fixing of serviceable cross arms, street light bracket etc, complete all as specified and directed. Note :- (i) Actual number of conductor including earth wire and shortest distance between the poles shall be measured for payment. No extra payment shall be made to the contractor for sag and jumper etc. (ii) Burnt /damaged jumpers of appropriate size shall be replaced by the contractor and cost of the same shall deemed to be included in the unit quoted rate.
2000
-
-
Trimming of tree branches of girth n. exc. 15cm along the alignment of LT/HT over head electric line which are touching or falling on ACSR conductor/ poles or near by sub stns etc at any at any height from GL and making sufficient clearance (not less than 1.5m) from conductor and taking down the same on the ground carefully, avaoiding damage of tne conductor/pole and removing to a distance n. exc 100m, complete all as specified and directed. Note :(i) Trimming of the branches/twigs shall be done on both sides of the conductor.
(ii) Trimming of the branches can be carried out twice at same location during the currency of contract, subject to atleast 5 months gap and necessary register should be maintained and be produced during claiming payment. (iii) Actual length of cutting shall be measured for payment
4500
-
-
Cleaning of area around transformer, LT panel, bus bar, VCB, RMUs, LT / HT Structure, pole, path of electrical Sub Staion / DG Set by scraping the grass by root and criperies, complete all as specified and directed.
Note : The cleaning of E/M installation can be carried out twice at same location during the currency of contract, subject to atleast 5 months gap and necessary register should be maintained and be produced during claiming payment.
4500
-
-
S&F in repair jumper wire, spiral type, insulated, aluminium conductor of cross section 50 Sqmm, suitable for low/high tension jumper wire with colour coding (red, yellow, blue and black), complete all as specified and directed.
100
-
-
S&F in repair porcelain viereous white or brown shackle type insulator including galalvanaized mild steel straps, washers, insulator bolts, washers and nuts 550 volts grade, 50mm height, 65mm dia and 9mm dia bolt size, complete all as specified and directed.
5
-
-
S&F in repair pin type porcelain vitreous, white or brown insulator including one galvanized mild steel spoindle, two galvanized iron washers and one galvanaized iron nut, 50mm height 65mm dia for 550 volts grade, complete all as specified and directed.
10
-
-
Taking down serviceable steel pole from root carefully, transporting to other places as directed and fixing of serviceable steel pole size (9 Mtr) complete with street light bracket and street light including excavation/earth work, disposal of surplus soil, provision PCC(1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in foundation, PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping, complete all as specified and directed.
6
-
-
S&F in repair danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20 x 15cm size, complete all as specified and directed.
120
-
-
S&F in repair danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 25 x 20cm size, complete all as specified and directed.
50
-
-
Note: An amount of Rs.1,05,025.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
-
-
-
Supply and fixing energy efficient ‘LED Flood Light 120 W LED luminaire with Aluminium dia cast housing, toughened glass cover with IP 66 protection, CCT 5700 K including fixing arrangment on wall/pole / surface and connecting cable up to nearest ceilign rose into flexible PVC conduit. Make : Crompton/Havells/ Surya/Philips
-
-
-
Evaluation Notes How It Works ?