Indian Oil Corporation Limited Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Indian Oil Corporation Limited - IOCL Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Oct 2024
Closing Date18 Nov 2024
Tender Amount₹ 52,71,730.45 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

Annual Rate Contract For Electrical Maintenance Works At Erpl Mourigram Hq Office And Colony

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Overall diameter upto 35 MM

-

-

562.74

... More
Overall diameter 35 MM but upto 55 MM

-

-

816.8

... More
Overall diameter 55 MM but upto 75 MM

-

-

1197.82

... More
Providing and laying medium quality, Class-B galvanised steel pipes of Tata / Jindal or approved equivalent make conforming to IS-12 39 [Part-I] in underground trenches, on steel, concrete or similar structures including cutting, threading, bending, supply & instal lation of supports, clamps, small iron structures, spacer, seats, plugs, bush, fittings / fixtures like bends, tees, nipples, reduce rs etc. all complete as per specification, drawing and direction of Engineer-in- charge. Item includes sealing of pipe ends & joints with bushes and bitumen based fillings and such other miscellaneous works so as to make piping water tight.

-

-

-

... More
50 mm dia

-

-

9190.78

... More
100 mm dia

-

-

10186.23

... More
Providing end termination of power/control cable including cutting, stripping, providing & fixing heavy duty type lugs, cable insula tion, providing & glanding single compression heavy duty brass cable gland conforming to IS-12943 (Dowell's or apporved equivalen t), wherever specified, providing heavy duty type aluminium lugs for power cables and copper lugs/connectors for control cables, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagging with aluminium tag,earthing of armou r, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-i n-Charge.

-

-

-

... More
2 x 6 sqmm

-

-

3285.47

... More
2 x 10 sqmm

-

-

3299.52

... More
2 x 16 sqmm

-

-

3462.95

... More
4 x 6 Sqmm

-

-

17501.17

... More
4 x 10 sqmm

-

-

3932

... More
4 x 16 sqmm

-

-

4653.57

... More
4 x 35 sqmm

-

-

4772.98

... More
4 x 50 sqmm

-

-

1160.77

... More
3-1/2 x 25 sqmm

-

-

5567.59

... More
3-1/2 x 35 sqmm

-

-

3173.02

... More
3-1/2 x 50 sqmm

-

-

1472.52

... More
3-1/2 x 95 sqmm

-

-

2197.44

... More
3-1/2 x 120 sqmm

-

-

2956.49

... More
3-1/2 x 150 sqmm

-

-

3853.74

... More
3-1/2 x 240 sqmm

-

-

4850.41

... More
Making straight through joints for medium voltage PVC armoured power & control cables (upto 1.1 KV grade) including cutting, strippi ng of cable insulation, excluding supply of cast resin straight through cable jointing kit and ferrules. All complete with labour an d materials as per drawings, specifications and directions of Engineer-in-charge.

-

-

-

... More
1 x 185 sqmm

-

-

2000.88

... More
1 x 240 sqmm

-

-

2070.12

... More
3-1/2 x 70 sqmm

-

-

16006.82

... More
3-1/2 x 95 sqmm

-

-

3235.23

... More
3-1/2 x 120 sqmm

-

-

9807.36

... More
3-1/2 x 150 sqmm

-

-

6541.26

... More
3-1/2 x 225 sqmm

-

-

4232.57

... More
4 x 50 sqmm

-

-

6687.53

... More
4 x 95 sqmm

-

-

3235.23

... More
4 x 120 sqmm

-

-

3269.12

... More
4 x 150 sqmm

-

-

6605.97

... More
4 x 185 sqmm

-

-

8003.47

... More
Supply of copper tube terminal heavy duty (crimping cable lug) of KSE / Dowells make or equivalent certified by EIC. of the followin g sizes.

-

-

-

... More
1.5 sqmm

-

-

55.46

... More
2.5 sqmm

-

-

59.94

... More
4 sqmm

-

-

69.74

... More
6 sqmm

-

-

89.68

... More
10 sqmm

-

-

93.81

... More
16 sqmm

-

-

51.12

... More
Supply of aluminium tube terminal heavy duty (crimping cable lug) of KSE / Dowells make or equivalent certified by EIC. of the follo wing sizes.

-

-

-

... More
2.5 sqmm

-

-

18.29

... More
4 sqmm

-

-

182.9

... More
6 sqmm

-

-

20.65

... More
10 sqmm

-

-

277.3

... More
16 sqmm

-

-

66.32

... More
25 sqmm

-

-

418.9

... More
35 sqmm

-

-

298.21

... More
50 sqmm

-

-

83.78

... More
70 sqmm

-

-

250.87

... More
95 sqmm

-

-

55.41

... More
185 sqmm

-

-

313.76

... More
240 sqmm

-

-

107.24

... More
Supply and fixing of earth bus bar of GI flat of following size on wall etc. with a clearance of 6 mm from the wall with spacing ins ulator GI rack bolts wherever necessary including drilling 6 mm dia holes at about 25 mm apart complete with double nuts, washers GI machine tools etc. all complete with labour and materials as per direction of the Engineer-in- Charge.

-

-

-

... More
50 X 6 MM GI FLAT

-

-

28611.46

... More
40 X 5 MM GI FLAT

-

-

22709.1

... More
25 X 5 MM GI FLAT

-

-

14047.9

... More
Providing salt and charcoal for plate earth electrode as required.

-

-

-

... More
96 kg charcoal and 5 kg salt

-

-

2832.26

... More
Providing and fixing of lightning conductor finial, made of 25mm dia. 300mm long, GI tube, having single prong at top, with 85mm dia . 6mm thick GI base plate including holes etc. complete as required.

-

-

5529.29

... More
Providing and fixing copper tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor as required,. (For v ertical run)

-

-

9904.51

... More
Providing and fixing GI tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor as required,. ( For horizontal run)

-

-

707.7

... More
Supply, fixing and connection of 250 V flush type / tumbler Anchor make or approved equivalent switch, socket bell push etc. on perp ex sheet on MS box inlcuding supply and fixing of nuts, bolts, etc. but excluding the perpex sheet all complete with labour and mate rials as per direction of the Engineer-in-Charge.

-

-

-

... More
1 way 5 / 6 amps. piano type switch with ISI mark

-

-

810.9

... More
2 way 5/6 amps. piano type switch with ISI mark

-

-

875.44

... More
1 way 15 / 16 amps. piano type switch with ISI mark

-

-

617.02

... More
2 way 15 / 16 amps. piano type switch with ISI mark

-

-

768.89

... More
Piano type 5 pins 5 / 6 amps. socket outlet

-

-

601.45

... More
flush type 6 pins 6 / 16 amps. Uni. socket outlet with ISI mark

-

-

1477.12

... More
Dimmer 400W / fan regulator

-

-

2566.03

... More
3 plate ceiling rose

-

-

857.27

... More
Mini Buzzer switch type

-

-

632.78

... More
Delux musical Bell

-

-

1774.43

... More
6 amp 3 pins switch socket combined ISI marked

-

-

678.15

... More
16 amp 5 pins switch socket combined ISI marked

-

-

920.05

... More
Installation, testing and commissioning of ceiling fan and regulator including wiring the down rod of standard length (upto 30 cm) w ith 1.5 sqmm, PVC insulated, copper conductor, single core cable etc. as required.

-

-

2208.25

... More
Extra for fixing the louvers / shutters complete with frame for exhaust fan of all sizes

-

-

2433.63

... More
Supply, fixing and connection of 250 V below given mosaic modular wiring accessories of M/s MDS or approved equivalent inlcu ding supplying and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the Engineer-in-Charge.

-

-

-

... More
6 amps. - 1 way - SP - 1 module switches

-

-

2111.26

... More
6 amps. - 2 way - SP - 1 module switches

-

-

1519.13

... More
10 amps. - 2 way - SP - 2 module switches

-

-

1182.18

... More
16 amps. - 2 way - SP - 1 module switches

-

-

2712.35

... More
6 amps. - 1 way - SP - 1 module push button

-

-

415.24

... More
230 V AC 1 module buzzer

-

-

1653.12

... More
6 amps. - 2 / 3 pins combined 2 module shutterred socket

-

-

1432.34

... More
6 / 16 amps. - 3 pins combined 3 module shutterred socket

-

-

1176.87

... More
2 pins - 1 module telephone socket

-

-

1036.51

... More
RJ 11 telephone socket 1 module

-

-

1470.4

... More
1 module blanking plate

-

-

595.31

... More
1 module - 8 mm cable TV antenna socket outlet

-

-

635.19

... More
6 pin 25 A modular type socket lSI Marked

-

-

1166.25

... More
25 A modular SPMCB

-

-

3219.04

... More
Supply and fixing of below given white cover plate with frame for mosaic wiring accessories of M/s MDS or approved equivalent inlcud ing supply and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the Engineer-in-Charge.

-

-

-

... More
Supply and fixing of below given metal flush boxes to accommodate mosaic wiring accessories of M/s MDS or approved equivalent inlcud ing supply and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the Engineer-in-Charge.

-

-

-

... More
1 / 2 module

-

-

2415.93

... More
3 module

-

-

2553.4

... More
4 module

-

-

2673.64

... More
6 module

-

-

2897.02

... More
12 module (6 x 2)

-

-

1710.76

... More
8 module

-

-

1581.91

... More
Supply and fixing of below given metal surface boxes to accommodate mosaic wiring accessories of M/s MDS or approved equivalent inlc uding supply and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the Engineer-in-Charge.

-

-

-

... More
1 / 2 module

-

-

966.18

... More
3 module

-

-

1096.34

... More
4 module

-

-

1210.21

... More
6 module

-

-

1421.66

... More
12 module (6 x 2)

-

-

954.8

... More
8 module

-

-

832.79

... More
Fixing of following light fittings attachments on MS hanger/supports/concrete wall structure /steel structure completed wi th lead in wires and other accessories all complete with labour and materials as per direction of the Engineer-in-Charge. (cost of l ight fittings/lamp control gears and other fittings shall be excluded).

-

-

-

... More
FLP/INCREASED SAFETY WELLGLASS/ BULKHEAD/ TUBELIGHT/ FLOODLIGHT

-

-

2501.07

... More
FLP/ INCREASED SAFETY CONTROL GEAR BOX/JUNCTION BOX/ SWITCH/SOCKET

-

-

2628.1

... More
RECESSED TUBELIGHT FITTING

-

-

2135.62

... More
GARDEN LIGHT FITTING

-

-

2220.29

... More
STREET LIGHT FITTING (UPTO 9 M HEIGHT)

-

-

4271.3

... More
STREET LIGHT FITTING (MORE THAN 9 M HEIGHT)

-

-

5695.09

... More
POST TOP LANTERN

-

-

1708.5

... More
FLOODLIGHT WITHOUT CONTROL GEAR

-

-

2262.65

... More
FLOODLIGHT WITHOUT CONTROL GEAR (MORE THAN 9 M HEIGHT INCLUDING ON FLDM)

-

-

2847.52

... More
"Fixing of wall monted fan completed with lead in wires and other accessories all complete with labour and materials as per direction of the Engineer-in-Charge. (cost of Fans shall be excl uded)"

-

-

1960.04

... More
Fixing of exhaust fans on existing opening, complete with lead in wires and other accessories all complete with labour and ma terials as per direction of the Engineer-in- Charge. (cost of fans shall be excluded)

-

-

-

... More
WITH LOUVER SHUTTER/MESH

-

-

3203.46

... More
FLP/IS EXHAUST FAN

-

-

6406.99

... More
Supply, installation, testing and commissioning of ceiling fans of Bajaj/Crompton Greaves/Khaitan/Usha make only including supply an d fixing of the electronic regulators with all necessary supports. All complete with labour and materials as per drawings, specifi cations and directions of Engineer-in-Charge.

-

-

-

... More
1400 MM SWEEP (WHITE)

-

-

16580.12

... More
Supply, installation, testing and commissioning of single phase , Fresh Air Fans / Heavy duty Exhaust Fans of Bajaj/Crompton Gr eaves/Khaitan/Usha make only including supply and fixing with all necessary supports All complete with labour and materia ls as per drawings, specifications and directions of Engineer-in-Charge.. NOTE: Necessary civil works required for fixing t he exhaust fans shall be in the scope of Contractor.

-

-

-

... More
FRESH AIR FAN WITH LOUVER SHUTTER 300MM SWEEP

-

-

13752.55

... More
Supply, installation, testing and commissioning of Wall Mounted Fans of Bajaj/Crompton Greaves/Khaitan/Usha make only including sup ply and fixing of the electronic regulators with all necessary supports. All complete with labour and materials as per drawings, sp ecifications and directions of Engineer-in-Charge.NOTE: Necessary civil works required for fixing the exhaust fans shall be in the s cope of Contractor.

-

-

-

... More
OSC. WALL & CABIN FANS OF 300MM SWEEP

-

-

16359.52

... More
OSC. WALL & CABIN FANS OF 450 MM SWEEP

-

-

25661.93

... More
Supply and installation of following street light pole with marshalling box to accommodate 3 Nos. of 4x10sqmm PVC armoured cable wi th Elemex terminal block, earthing of pole/marshalling box but excluding lighting fixtures etc. with 8 SWG GI wire including ma king PCC (1:3:6) foundation, painting and numbering all complete with labour and materials as per standard drawi ngs, specifications and directions of Engineer-in-Charge. NOTE: Cable required from lighting fixture to Marshalling box will be supp lied by Owner .

-

-

-

... More
12 MTR HEIGHT (SINGLE ARM) (IS:2713, DESG:410SP- 59) Botttom section: 5.8 m x 165.1 mm x 4.85mm Middle section:3.10 m x 139.7 mmx 4. 50 mm TOP section :3.10 m x 114.3 mm x 3.65 mm Arm: 1.5 m x 48.4 mm x 3.2 mm (Length x OD x thickness)

-

-

44563.46

... More
12 MTR HEIGHT (DOUBLE ARM) (IS:2713, DESG:410SP-59) Botttom section: 5.8 m x 165.1 mm x 4.85mm Middle section:3.10 m x 139.7 mm x 4.50 mm TOP section :3.10 m x 114.3 mm x 3.65 mm Arm: 1.5 m x 48.4 mm x 3.2 mm (Length x OD x thickness)

-

-

45964.21

... More
Supply, fixing in position, installation, connection, testing and commissioning of the following LED Light Fittings rated for 240V, 50Hz, 1-ph AC fo the make of Philips/Osram/Havells/Wipro/Bajaj/Eveready/SYSKA/Oreva/Crompton or equivalant Indian make). Item includ es Installation & Connection of Lighting Fixture on Existing Poles/HMT/FLT, Metallic Structures, Walls, Buildings, Roofs, Sheds and other facilities upto a height of 30m, removal of the, Complete in All respect with Materials, Transportation, Labor, Tools etc..

-

-

-

... More
9W, LED Tube Light Fitting, 2FT, 230V AC

-

-

2654.88

... More
40W LED Light/Lamp, 230V AC, 50Hz

-

-

13625.22

... More
120W LED Flood Light Fitting, with IP65, 230V AC, 50Hz

-

-

50469.9

... More
LED Light Driver of Flood Lights

-

-

60618.96

... More
18W, LED Tubelight Fighting, 230V AC, 50Hz

-

-

2318.23

... More
09W, LED Bulb/Lamp, 230V AC, 50Hz

-

-

377.25

... More
Supply, fixing and connection of Philips/approved equivalent make LED Down lighter, suitable for Recessed mounting made of pressure diecast alluminium body with powder coating, acrylic diffuser with Driver as per IS: 15885 (Part 2/ Sec 13) : 2012 , o perating voltage-Venture range-Venture of 150 to 265 Volts AC, P.F 0.9, Surge-Venture protection: 2KV, THD10% with high power LED 's having efficacy of 100 lumins / watt, CCT: 3000K - 5700K, minimum CRI 70, Luminaire performance complies to IS 10322 (Part 5 / Sec-3) etc., complete including supply & fixing of lead in wire, nuts, bolts, screws etc. All complete with labour and materials a s per directions of Engineer-in-Charge.

-

-

-

-

-

2439.91

-

-

15452.81

-

-

11182.86

-

-

4798.47

-

-

12809.49

... More
Supply, fixing and connection of Philips/approved equivalent make LED Slim Panel Round /Square suitable for Recessed / Surface mou nting made of diecast alluminium body with powder coating, acrylic diffuser with Driver as per IS: 15885 (Part 2/ Sec 13) : 20 12 , operating voltaGE-Venture ranGE- Venture of 150 to 265 Volts AC, P.F 0.9, SurGE-Venture protection: 2KV,THD10%, with high power LED's having efficacy of 100 lumins/watt,CCT: 3000K - 5700K, minimum CRI70, .etc., complete including supply & fix ing of lead in wire, nuts, bolts, screws etc. All complete with labour and materials as per directions of Engineer-in-Ch arge.

-

-

-

-

-

2358.58

-

-

4066.52

-

-

5400.34

-

-

8539.72

-

-

9353.03

-

-

35378.76

... More
36/40W (600MMX600MM) SQUARE TYPE

-

-

57744.6

... More
LIGHTING CONTROL

-

-

-

... More
Supply, installation,testing and commissioning of occupancy sensor based on PIR technology-non regulated programmable

-

-

27888.36

... More
Supply, installation,testing and commissioning of occupancy sensor based on microwave technology-non regulated programmable

-

-

52921.82

... More
Rewinding of 1-phase/3-phase electrical motors of various voltage grades/makes/types and of following capacities as per th e original specifications & types/gauge of rewinding/winding wire, insulation of various points inside slots/overhang and overall fi nal layers of insulation/tapes as per the original motor specifications, after baking to required temperature and applying insulatin g varnish (Dr-Beck & Co. make & type), providing glass/other types of sleaves on connection wires from inside motor winding to conn ection plate. The winding, varnishing, tapes and other materials required for completion of this complete job is in the scope of co ntractor excluding transportation to & from Owner’s works to Contractor's rewinding shop. which shall be paid seperately on trip b asis.The winding wire will be Devi Dayal make and insulation tapes shall be ISI marked & of reputed manufacturers as per decisi on of Engineer-in- Charge. This also includes repair/replacement of connection plate completely including insulating sheet, nut s, bolts, washers and other hardwares as per original specifications. This further includes replacement of bearings (DE & NDE ) of SKF make & greasing (IOC/HP make Servogem 2 or equivalent). This further includes satisfactory trial of motors at Owner’s prem ises at No load as well as at Full load. The Contractor will guarantee the rewound motors for satisfactory performance for a period of minimum six months at owner’s premises & if any such rewound motor fails within six months, it is to be rewound again by Contrac tor free of cost. All complete with labour and materials as per directions of Engineer-in-Charge.Note: Burnt winding wire shal l be kept by Contractor. Bearing Shall be supplied by IOCL

-

-

-

... More
Motors above 7.5 KW but upto including 11 KW

-

-

10921.42

... More
"Rewinding of ceiling/pedestal/exhaust/air circulator fans of all types/sizes/make including 1-phase and 3-phase type exhaust fans max. upto 2.2 KW capacity and supply of super enameled win ding wire (Devi Dayal make, ISI marked insulation materials required). This also includes replacement of single/double bearing SKF make/bushes (as per original make) and overhauling of fan and all jobs related to complete this work in totality. This also includes removal of fans from site, installation and commissioning after testing of rewound fans and replacement of condenser, if required. This also includes transportation from site after dismantling to Contractor’s workshop and back to site. Note: Contractor has to give guarantee for rewinding of above items for a period of six months and if winding is burnt again within six months of working of fans, it has to be rewound again of Contractor. The burnt winding shall be kept by Contractor."

-

-

-

... More
Ceiling/pedestal fans

-

-

4881.66

... More
Exhaust/air circulators fans.

-

-

6878.75

... More
Overhauling of exhaust/air circulator fans of various types/sizes makes and its bearings including removal from site, cl eaning, greasing after degreasing, assembling and fixing in position, testing and commissioning including transportation from site t o workplace and back all complete with labour and materials as per directions of Engineer-in-Charge.

-

-

-

... More
Excluding the cost of bearings (Bearings if necessary will be supplied by Owner ).

-

-

1863.28

... More
Including supply and fixing of bearings of SKF make (02 Nos. bearings)

-

-

2995.55

... More
Overhauling of ceiling/pedestal fans of various types/ sizes/make and its bearings including removal from site, clean ing, greasing after degreasing, assembling and fixing in position, testing and commissioning including transportation from site to workplace and back. All complete with labour and materials as per directions of Engineer-in-Charge.

-

-

-

... More
Excluding the cost of bearings. (Bearings if necessary will be supplied by Owner .

-

-

993.7

... More
Including supply and fixing of bearings of SKF make and bushes (as per original make) of both sides by Contractor.

-

-

798.81

... More
Supplying and fixing busbar chamber with 4 strips busbars of length 300 mm, made of aluminium alloy or wrought aluminium, sui table for following capacity, complete with all accessories including connections, earthing the body etc. as required.

-

-

-

... More
100 amps.

-

-

12267.22

... More
200 amps.

-

-

16013.96

... More
"Providing and fixing 32 amps. Metal clad, TP&N switch fuse unit, 415/500 volts, without H.R.C. fuses including drilling holes on th e board, connections, earthing the body etc. as required. 1.ISI marked HRC fuses shall be used. 2.TPN of English Electric / L&T / Crompton / Havells / Standard /equivalent make shall be used as per direction of Engineer-in-Charg e."

-

-

28759.08

... More
"Providing and fixing 63 amps. Metal clad, TP&N switch fuse unit, 415/500 volts, without H.R.C. fuses including drilling holes on th e board, connections, earthing the body etc. as required. 1.ISI marked HRC fuses shall be used. 2.TPN of English Electric / L&T / Crompton / Havells / Standard /equivalent make shall be used as per direction of Engineer-in-Charg e."

-

-

20067.2

... More
"Supplying and fixing 5 amps. To 32 amps. Rating, 240/ 415 volts, 50Hz, 10KA 'C' curve, miniature circuit breaker (suitable for motor and other inductive loads and conforming to IS 8828: 1996, IEC 60898: 2002) of following poles in the existi ng MCB DB complete with connections, testing and commissioning etc. as required. Note: ISI marked MCBs of Havells / Loadster / Indo Kopp or equivalent make shall be used as per direction of Engineer- in-Charge."

-

-

-

... More
Single pole

-

-

2577.36

... More
Single pole and neutral

-

-

35571.1

... More
Double pole

-

-

7664.22

... More
Triple pole

-

-

11218.38

... More
Triple pole and netural

-

-

14720.38

... More
Four pole

-

-

16889.46

... More
"Providing and fixing of metal clad, rewireable type switch fuse unit confirming to IS: 13497 (Part-I & II) of following ratings (Am p / Volt) including drilling holes on the board, connections, earthing the body etc. as required. Note: SFU of English Electric / L&T / Crompton / Havells /Standard /equivalent make shall be used as per direction of Engineer-in-Ch arge."

-

-

-

... More
32A / 240V, Double pole

-

-

31665.3

... More
63A / 415V, Double pole

-

-

17361.99

... More
32A / 415V, Tripple pole & neutral

-

-

13820.75

... More
63A / 415V, Tripple pole & neutral

-

-

30218.8

... More
100A / 415V, Tripple pole & neutral

-

-

50932.05

... More
200A / 415V, Tripple pole & neutral

-

-

57398.62

... More
Supplying and fixing following rating, three pole and four pole, 415 volts, isolator in the existing MCB DB complete with connection s, testing and commissioning etc. as required. Note: ISI marked isolato rs shall be used.

-

-

-

... More
40 amps. Tripple Pole

-

-

4430.9

... More
40 amsp. Four Pole

-

-

5876.16

... More
63 amps. Four Pole

-

-

5954.99

... More
125 amps. Four Pole

-

-

8115.69

... More
"Supplying and fixing following rating, double pole, (single phase neutral), 240 volts, residual current circuit breaker (RCCB/ELCB) , ISI marked, having a sensitivity current indicated miliamperes in the existing MCB DB complete with connections, testing an d commissioning etc. as required. Note: ISI marked RCCB/ELCB shall be used."

-

-

-

... More
25 amps, 100 mA

-

-

10904.56

... More
32 amps., 30 mA

-

-

23590.09

... More
32 amps, 100 mA

-

-

11604.24

... More
40 amps, 100 mA

-

-

11604.24

... More
63 amps, 100 mA

-

-

15039.04

... More
Supplying and fixing of following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral link, eachrth bar, din, bar, detachable gland p late, interconnections, including painting earthing etc.as required as per IS 8623; IS 13032; IEC 61439-3 and as per direction of Engineer-in-Charge.

-

-

-

... More
2+ 8 way

-

-

9132.85

... More
2 + 12 way

-

-

10631.39

... More
Supplying and fixing of following way, prewired single pole and neutral sheet steel MCB consumer unit, 240 volts, o n surface / recess complete with tinned copper busbar, neutral link, earth bar, din bar, hinged front cover for the MCB k nobs, detachable gland plate, inter connections including painting, earthing etc. as required (with IP 43 protection and metal door) and as per direction of Engineer-in-Charge.

-

-

-

-

-

10633.69

... More
8 - Way

-

-

22573.99

... More
Supplying and fixing of following way, prewired single pole and neutral sheet steel MCB consumer unit, 240 volts, on surface / reces s complete with tinned copper busbar, neutral link, earth bar, din bar, hinged front accrylic cover for the MCB knobs, detachable gl and plate, inter connections including painting, earthing etc. as required (with IP 54 protection).

-

-

-

... More
2+4 Way

-

-

49545.6

-

-

15917.43

... More
Supplying, installation, testing and commissioning of surface/recess mounting, vertical type, compartmentalised, 415 volts, T PN MCB distribution board of sheet steel, 1.6 mm. thick, dust protected, duly phosphatized and painted, inclusive of 200 amps. tin ned copper busbars, eachrth bar, common neutral link, din bar for mounting MCB's detachable gland/knock out plates and with built in loose wire box, and superior make terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of P VC insulated copper wires between the busbars and the MCB's as well as the incomer and upto the terminal connectors/ neutral link an d reachdy for installation, of following ways (but without MCB's and incomer) as required with IP 42 protection plus accrylic door.

-

-

-

... More
4 - Way

-

-

58440.68

... More
8 - Way

-

-

29828.16

... More
Supplying and fixing Cable End Boxes (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 24 0 volts, on surface/ recess, complete with testing and commissioning etc. as required and as per direction of Engineer-in-Charge.

-

-

-

... More
4 - Way

-

-

3926.15

... More
8 - Way

-

-

1865.23

... More
Supply, fixing and connection of following KNIFE TYPE (DIN) / BOLTED HRC fuse link AS PER IS:13703:1993 & IEC 269:1986 of M/S HAVELL /L&T /G EC Astholm/Standard /MDS make or approved equivalent in distribution board etc.all complete with labour and materials as per direction of Engineer-in-charge.

-

-

-

... More
20-32 AMP Size 000

-

-

699.5

... More
63 AMP Size 000

-

-

798.51

... More
125 AMP Size 00

-

-

1505.07

... More
160-200 AMP Size 1

-

-

1389.19

... More
Supply and installation of L&T / Siemens OR equivalent make DOL / Star-Delta motor starter (WITH ALL ACESSARIES INCLUDING O/L RELAY/ TIMERS ETC.) conforming to IS:13947-4 on walls/steel structure, connection of cables all complete with labour and materials as per direction of the Engineer-in-Charge.

-

-

-

... More
UPTO 5.5KW, DOL

-

-

3779.81

... More
7.5KW , DOL

-

-

8250.06

... More
11KW , Star-Delta

-

-

24475.44

... More
Supply, fixing and connection of following equipments in panels including small mechanical works and supply of all fixing materials. All complete with labour and materials as per the direction of Engineer-in-Charge

-

-

-

... More
Power Contactor (with 1NO + 1NC)- Upto 25 Amp (AC3) for AC standard coil voltage - 110, 220, 240, 415 V, 50Hz Type MNX25 of L&T or e quivalent

-

-

2062.55

... More
Power Contactor (Upto 2NO + 2 NC)- Above 45 Amp but upto 140 Amp (AC3) for AC standard coil voltage - 110, 220, 240, 415 V, 50Hz Typ e MNX140 of L&T or equivalent

-

-

19394.06

... More
"Supply & Installation of feeder pillars of GI sheet of 14SWG of depth 600 to 800 mm, placing on foundation including suppl y of bolts, making arrangments for fixing of switch fuse unit / contactor etc all complete including labour and materials as p er drawing and direction of the Engineer-in-Charge. Note: 1.Only front area will be measured and paid. 2.Foundation shall be paid under separate item. 3.Switch fuse unit/contactor etc. shall be paid under separate item."

-

-

-

... More
WITH 25X6 MM CU BUSBARS

-

-

7836.57

... More
WITH 40X6 MM CU BUSBARS

-

-

10185.91

... More
Supply and fixing of led indication lamp in the panels. leds shall be provided with leakage voltage protection upto 40v. Operating v oltage shall be 110V / 220V / 230V /AC /DC, Panel cutouts shall be 22.5 / 25.5 / 30.5 mm. Terminals shall be shrouded for finger pro ofing and safety are with captivated washers to hold two lugged (fork / pin) wires in one terminal. Job includes supply of labor and various undry materials required and finally testing of led's for + following ed's

-

-

-

... More
Red / yellow / amber / green / milky white led's

-

-

857.68

... More
Blue led

-

-

1429.45

... More
Supply of following rating and breaking capacity 4 pole MCCB with thermomagnetic release along with terminal spreaders as per direct ion of Engineer-in-Charge.

-

-

-

... More
125 Amps, 36kA

-

-

19067.2

... More
200 Amps, 36 kA

-

-

39176.26

... More
250 Amps, 50kA

-

-

96398.74

... More
Supply of accessories for transformers

-

-

-

... More
Supply & replacement of OTI as per direction of Engineer-in- Charge.

-

-

9946.73

... More
Supply & replacement of Buchholz relay as per direction of Engineer-in-Charge.

-

-

12433.41

... More
Supply, fixing, installation of Breather Unit without silicagel suitable for upto 750gm silicagel as per direction of Engineer-in-Ch arge.

-

-

2001.8

... More
Supply, fixing, installation of Breather Unit without silicagel suitable for upto 1000gm silicagel as per direction of Engineer-in-C harge.

-

-

2430.73

... More
Conduit length above 3.5m and upto 4.5m - Group C

-

-

12191.17

... More
Long point (conduit length more than 6m but upto and including 10m) -

-

-

17359.57

... More
"Wiring for light point / fanpoint / exhaust fan point / call point with 1.5 sqmm FRLS PVC insulated, copper conductor cable in surf ace PVC medium duty conduit as required. Job includes cost of wire, conduit with accessories, ceiling rose, MS box with phenolic la minated sheet and switches etc. as required. Note: Only ISI marked conduits, cables, switches and socket outlets shall be used."

-

-

-

... More
Long point (conduit length more than 6m but upto and including 10m) -

-

-

8340.48

... More
"Wiring for twin control light point with 1.5 sqmm PVC insulated, copper conductor cable in recessed, PVC medium duty conduit with 2 way 5/6 amps. piano type switch etc. as required. Job includes cost of wire, conduit with accessories, ceiling rose, MS box with p henolic laminated sheet and switches etc. as required. Note: Only ISI marked conduits, cables, switches and socket outlets shall be used."

-

-

12307.99

... More
"Wiring for 3 pin 5/6 amps. plug point with 1.5 sqmm PVC insulated copper conductor cable including providing and fixing 3 pin 5/6 a mps. socket outlet on switch board, (in surface PVC conduit wiring system) and 5/6 amps. tumbler / piano switch, earthing the 3rd pin, painting etc. as required (to be used only in non-residential buildings). Job includes cost of wire, conduit with accessor ies, ceiling rose, MS box with phenolic laminated sheet and switches etc. as required. Note: Only ISI marked conduits, cables, switches and socket outlets shall be used."

-

-

5095.83

... More
"Wiring for light/ power plug with 2X1.5 sq. mm FRLS PVC insulated copper conductor single core cable in recessed medium duty PVC co nduit alongwith 1 No. 1.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Note: Only ISI marked conduits & cables shall be used."

-

-

3685.61

... More
"Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in recessed medium duty PVC cond uit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Note: Only ISI marked conduits & cables shall be used."

-

-

5052.52

... More
"Wiring for submain wiring with following sizes of FRLS PVC insulated, copper conductor, single core cable in recessed, PVC medium duty conduit as required. Note: Only ISI marked conduits & cables shall be used."

-

-

-

... More
2 x 2.5 sqmm with 2.5 sqmm earth wire

-

-

2105.71

... More
2 x 4 sqmm with 4 sqmm earth wire

-

-

2526.26

... More
2 x 6 sqmm with 6 sqmm earth wire

-

-

15757.72

... More
2 x 10 sqmm with 6 sqmm earth wire

-

-

4127.88

... More
2 x 16 sqmm with 6 sqmm earth wire

-

-

26346.45

... More
"Supply and fixing of following size of PVC conduit alongwith the accessories in recess including cutting the wall and maki ng good the same in case of recessed, conduit as required: Note: Only ISI marked conduits shall be used."

-

-

-

-

-

10695.52

-

-

11523.88

... More
"Providing and fixing following size of PVC casing and caping on surface as required. Note: Only ISI marked caping and casing shall be used."

-

-

-

... More
20 mm x 10 mm

-

-

392.76

... More
25 mm x 10 mm

-

-

4130.59

... More
"Supply and fixing of metal box of following size (nominal) in recess with suitable size of phenolic laminated sheet cover in the front including painting etc. as required."

-

-

-

... More
75 mm x 75 mm x 60 mm deep

-

-

865.29

... More
100 mm x 100 mm x 60 mm deep

-

-

1999.98

... More
150 mm x 75 mm x 60 mm deep

-

-

2058.27

... More
150 mm x 150 mm x 60 mm deep

-

-

2906.1

... More
180 mm x 100 mm x 60 mm deep

-

-

2286.6

... More
200 mm x 125 mm x 60 mm deep

-

-

2991.18

... More
"Supply and fixing of Sunmica/Hylem sheet cover of required cutout for mounting on boards, DBs similar type of electrical ins tallation or wherever required as per directions of Engineer-in-Charge.. The job includes the finishing and mounting of the cutout sheet alongwith the supply of necessary hardwares, screws etc. All complete with labour and materials as per directions of Engineer -in- Charge. Minimum thickness of Hylem sheet shall be 2mm."

-

-

43689.5

... More
RUBBER HAND GLOVES: Rubber hand gloves suitable for 11/6.6 KV operation with ISI mark.

-

-

7458.76

... More
Excavation in unpaved areas of earth in work sites for conventional cable trenches for a depth upto 1.5 metres including shoring, strutting etc. (if necessary), backfilling the trench, job complete in all respects, including all labour and materials comple te as per drawings, specification and directions of Site Engineer / Engineer-in-Charge

-

-

4082.09

... More
WBM Road/concrete breaking for cable trenches including required shoring strutting etc., and repairing of the road/dyke to origina l condition and disposing off excess materials (within the work site) job complete in all respects including the cost of labou r, tools, materials, load, lift hire charges of equipments, if any, complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.

-

-

26747.83

... More
Power cables LT : OD upto 20 mm

-

-

424.92

... More
Power cables LT : OD above 20 mm and upto 40 mm

-

-

609.94

... More
Power cables LT : OD above 60 mm

-

-

876.15

... More
Centrifuging, filtering and dehydrating of the transformer oil of transformer to improve insulation level to the value recommended as per the relevant ISS and the manufacturer's recommendations and as per specifications and directions of the Site Engineer/Enginee r-in-Charge including supply of labour, tools and materials and all services rendered complete.

-

-

67837.04

... More
Supply, erection & installation of MS cable markers, including excavation, installation of the markers, cement concrete grouting, ba ckfilling, materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.

-

-

14611.41

... More
Supplying, installation, testing of GI earthing electrode, including the supply and installation of the CI cover, charcoal /special backfill etc. and construction of chamber; complete as per drawings,specifications and directions of the Site Engineer, Including the cost of all labour, tools, materials etc. complete in all respects.

-

-

96431.13

... More
Supply and installation of shock treatment chart framed in good quality glass in English / Hindi / Local Language.

-

-

5285.81

... More
1 light point controlled by 1 switch

-

-

15354.63

... More
2 light points controlled by 1 switch

-

-

18853.69

... More
LED Ceiling Point: Supply and fixing of surface mounted LED ceiling light fitting type Mainstream spot Aura 15W of PHILLIPS or equiv alent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including i nstallation.

-

-

15087.13

... More
Ceiling fan, BEE 5 star rated, with electronic regulator & other accessories and fittings etc. of or approved make with 56" Sweep s ize

-

-

20565.34

... More
LED light fittings, Recess mounting type, Sereno LED-RC869B LED 30S-6500 PSE W30L120 D8 or equivalent approved make with LEDs: Suppl y and fixing of recess mounted weather proof light Sereno LED-RC869B LED 30S-6500 PSE W30L120 D8 or equiavlent approved make with L EDs, 42 W or more, having 2950 lumens or more output. LED Fitting of PHILLIPS or equivalent approved make complete with all accessor ies such as LED module, driver, optics, thermal sink, connector blocks etc including installation with LED of approved make.

-

-

92964.18

... More
DN170C LED10S-6500 PSU WH: Supply and fixing of surface mounted weather proof light DN170C LED 15 W having 1000 lumens output fitti ng of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including installation.

-

-

100997.73

... More
Items for Manpower services

-

-

-

... More
Contractor services charges on minimum wages

-

-

353917.02

... More
Fixed monthly wages for providing services of 02 (two) nos. of electrician/technician for LT electrical works up to 415 V AC for Mourigram HQ office & colony assistance services are required on round the clock, Scope of work under the scope of this works shall include but not limited to followings :1. Maintenance, servicing and testing of 630A LT PCC Panel.2. Cleaning of 630A LT PCC Panel.3. Maintenance of 500 KVA Transformer.4. Regular cleaning of 500 KVA Transformer.5. Measurement of earthing resistance including transportation of earthing electrodes, cables etc. from stores to site.6. Cleaning of cable trenches of depth up to 3 meter and width 1.5 meter of cable galleries, and other locations etc.7. Cleaning of lights fitting fixtures and fan etc.8. Mourigram HQ has been procured the new 160 KVA DG set. In view of this, Labours to be required for refuelling of owner supplied Diesel and lube etc. in DG set.9. Maintenance of 160 KVA DG set.10. Regular cleaning of 160 KVA DG set.11. Schedule maintenance and regular cleaning of VCB.12. Attending and rectification of complaint in the office and colony.13. Schedule maintenance and regular cleaning of 25 kW Solar systems.14. Supervision of DG set during running.15. Day to day electrical maintenance works for office and colony and various services as per scope of work mentioned in SCC-T echnical and as per direction from the of EIC/SE. Proper license as per local rules should be there with the personnel. The rate of minimum wages and statutory & incidental charges shall be on following heads : 1. Minimum Wages as per notification of Central Government/State Government (whichever is higher) from time to time. 2. PF contribution as per statutory rates in force(employer's share) 3. Leave Encashment @ 2.5 days per month. 4. Gratuity payment per month (i.e. 4.8%). 5. Any increase in the fixed component of monthly wages/charges mentioned below due to revision of Minimum wages declared by the Govt. after 01.10.2024, the arrears for the specified number of contract manpower and its impact on PF & EDLI, ESI, Leave, Gratuity and Bonus shall have to be paid by the Contractor to his worker and the same shall be reimbursed by IOCL to the Contractor on production of necessary proof of payment.

-

-

1572964.45

... More
Fixed monthly wages for Providing services of 1 (one) no of DG operator on as and when required basis for 24 hours emergency manual operation of DG set. As per directions of EIC/SE. Proper license as per local rules should be there with the personnel. The rate of minimum wages and statutory & incidental charges shall be on following heads : 1. Minimum Wages as per notification of Central Government/State Government (whichever is higher) from time to time. 2. PF contribution as per statutory rates in force(employer's share) 3. Leave Encashment @ 2.5 days per month. 4. Gratuity payment per month (i.e. 4.8%). 5. Any increase in the fixed component of monthly wages/charges mentioned below due to revision of Minimum wages declared by the Govt. after 01.10.2024, the arrears for the specified number of contract manpower and its impact on PF & EDLI, ESI, Leave, Gratuity and Bonus shall have to be paid by the Contractor to his worker and the same shall be reimbursed by IOCL to the Contractor on production of necessary proof of payment

-

-

786482.08

... More
Uniform charges

-

-

-

... More
Charges which will be borne by IOCL towards Uniform consisting of 2 trousers, 2 shirts, 2 pairs of socks, 1 pair of black shoes (Bata/Liberty) and 1 woolen full sleeves sweater@ maximum Rs. 5123.40/- per person per year (Inclusive of GST)

-

-

30740.4



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.