Indian Institute Of Management Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Indian Institute Of Management - IIM Tender

Services
Eprocure
Opening Date11 Jun 2021
Closing Date15 Jul 2021
Tender Amount₹ 11,90,167 
Notes
Download

Costs

Summary

Ed/iimc/nit/1/20-21 /52 3rd Call

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(A) Compressor starting relay :- I. Box type for AC units (Arvind / Ranutrol)

20

-

372.88

... More
(A) Compressor starting relay :- II.Box type for Refrigerator / Deep freeze / Water Cooler (Arvind / Ranutrol)

8

-

326.27

... More
(A) Compressor starting relay :- III. Open type with overload protection for Refrigerator, / Deep freeze /Water Cooler (Arvind / Hitech)

4

-

279.66

... More
(B) Three core round PVC insulated Copper wire(flexible) as per following :- I.1.5 sq. mm (KDK)

8

-

104.41

... More
(B) Three core round PVC insulated Copper wire(flexible) as per following :- II.2.5 sq. mm (KDK)

8

-

127.12

... More
(B) Three core round PVC insulated Copper wire(flexible) as per following :- III.Fixing charge of wire (wire is Dept. supply)

8

-

42.37

... More
(C) Supply of compressor starting capacitor (Aluminium base, Make- Sarada/ Havells) of following capacity :- I.Above 20 MFD upto 40 MFD

10

-

174.32

... More
(C) Supply of compressor starting capacitor (Aluminium base, Make- Sarada/ Havells) of following capacity :- II.Above 40 MFD upto 80 MFD

20

-

372.88

... More
(C) Supply of compressor starting capacitor (Aluminium base, Make- Sarada/ Havells) of following capacity :- III.Above 80 MFD.

30

-

279.66

... More
(C) Supply of compressor starting capacitor (Aluminium base, Make- Sarada/ Havells) of following capacity :- IV.6-20 MFD

5

-

186.44

... More
(D) Supply of Compressor/ blower motor running capacitor (Aluminium base , Make-Sarada/ Havells) of following capacity :- I.Above 30 MFD

40

-

419.49

... More
(D) Supply of Compressor/ blower motor running capacitor (Aluminium base , Make-Sarada/ Havells) of following capacity :- II.Above 20 MFD upto 30 MFD.

20

-

372.88

... More
(D) Supply of Compressor/ blower motor running capacitor (Aluminium base , Make-Sarada/ Havells) of following capacity :- III.Above 6 MFD upto 20 MFD.

10

-

279.66

... More
(D) Supply of Compressor/ blower motor running capacitor (Aluminium base , Make-Sarada/ Havells) of following capacity :- IV.4 – 6 MFD.

50

-

233.05

... More
(E) Supply of Overload protector for following types of Compressor:- I. 0.75 to 2TR capacity. (Sriram)

8

-

326.27

... More
(E) Supply of Overload protector for following types of Compressor:- II. 1/6 TR / 1/3 TR / 1/2 TR / 1/4 TR capacity (Sriram)

8

-

279.66

... More
(F) Supply of selector switch for Window / Split ACC units. (Resmi / Arvind).

12

-

111.86

... More
(G) Supply of air filter for window / split AC unit.

150

-

233.05

... More
(H) Supply of Auto thermostat switch for following different capacity Refrigerator/ water cooler / Deep freeze/ Air conditioning unit :- i. WRAC / SAC unit (switch make-Renutrol / Annapurna).

10

-

512.71

... More
(H) Supply of Auto thermostat switch for following different capacity Refrigerator/ water cooler / Deep freeze/ Air conditioning unit :- ii. Water cooler (switch make-Renutrol / Annapurna).

10

-

489.41

... More
(H) Supply of Auto thermostat switch for following different capacity Refrigerator/ water cooler / Deep freeze/ Air conditioning unit :- iii. Deep Freeze (Switch make-Renutrol / Infoss).

2

-

466.1

... More
(H) Supply of Auto thermostat switch for following different capacity Refrigerator/ water cooler / Deep freeze/ Air conditioning unit :- iv. Refrigerator (Renutrol / Infoss).

2

-

419.49

... More
(I) Supply of front grill cover compatible with the running WRAC / SAC units.

3

-

1864.41

... More
(J) (i) Supply of base tray for AC units (size and iron sheet gauge thickness as per original tray used.

5

-

1864.41

... More
(J) (ii) Supply of cabinet for AC unit (size and iron sheet gauge thickness as per original cabinet used)

3

-

1677.97

... More
(K) Supply of following spare for AC unit blower motor :- i. Condenser fan blade (same as per original sample).

8

-

1025.42

... More
(K) Supply of following spare for AC unit blower motor :- ii. Evaporator runner (same as per original sample).

5

-

1677.97

... More
(L) Supply of Fan blade for Water cooler / Deep Freeze / Freeze. (same as per original sample).

6

-

372.88

... More
(M) Supply of Inlet /outlet water tap (Brass) for Water cooler.

4

-

466.1

... More
(N) Supply of Float valve (Brass with brass nipple) for Water cooler.

4

-

512.71

... More
(O) Supply and fixing of blower motors (Crompton Greaves / Universal / DLF) for the following :- (i) WRAC/SAC unit.

5

-

1398.31

... More
(O) Supply and fixing of blower motors (Crompton Greaves / Universal / DLF) for the following :- (ii) Water cooler/Deep Freeze.

5

-

1351.69

... More
(O) Supply and fixing of blower motors (Crompton Greaves / Universal / DLF) for the following :- (iii) Compressor cooler (Deep Freeze).

5

-

838.98

... More
(P) (i) Supply of Blower motor with blade (approved brand) for frost free Refrigerator.

2

-

512.71

... More
(P) (ii) Supply of PTCR (approved brand as per original sample)

2

-

522.03

... More
(Q) Supply and fixing of new Compressor (Carrier/Hitachi/ Kirloskar) for AC / Water cooler / Refrigerator / Deep Freeze (Job under Q includes complete work with new capillary tube, strainer , charging of refrigerant gas etc. Original challan of compressor to be produced)as mentioned below :- a. Reciprocating type : i. Above 0.5 TR upto 1 TR

2

-

7457.63

... More
a. Reciprocating type : ii. Above 1 TR upto 2 TR

2

-

8389.83

... More
a. Reciprocating type : iii. Upto 0.5TR

2

-

6059.32

... More
b. Rotary type : i. Upto 1 TR

2

-

7457.63

... More
b. Rotary type : ii. Above 1 TR upto 2 TR

4

-

8389.83

... More
(R) Supply, fitting and commissioning of AC / SAC’s condensing unit (Copper tube as per sample design) including Capillary tube , strainer & Refrigerant Gas charging to set right the following AC to work satisfactorily. (i) Above 1 TR upto 2 TR AC

4

-

6779.66

... More
(R) Supply, fitting and commissioning of AC / SAC’s condensing unit (Copper tube as per sample design) including Capillary tube , strainer & Refrigerant Gas charging to set right the following AC to work satisfactorily. (ii) upto 1 TR AC/WC

2

-

5932.2

... More
Repairing of defective / burnt compressor after dismantling including replacement of motor winding, big & small end bush, suction & discharge reeds, compressor oil and re – installation of the same for the following (incl.Gas charging, leg rubber,clip,connector etc) :- I. Above 0.5 TR upto 1 TR Capacity

10

-

3262.71

... More
Repairing of defective / burnt compressor after dismantling including replacement of motor winding, big & small end bush, suction & discharge reeds, compressor oil and re – installation of the same for the following (incl.Gas charging, leg rubber,clip,connector etc) :- II. Above 1 TR upto 2 TR Capacity

10

-

3728.81

... More
Repairing of defective / burnt compressor after dismantling including replacement of motor winding, big & small end bush, suction & discharge reeds, compressor oil and re – installation of the same for the following (incl.Gas charging, leg rubber,clip,connector etc) :- III.Upto 0.5 TR

2

-

2423.73

... More
Repairing of damaged / burnt blower motor including rewinding of Armature coil, heat varnishing, Supply & fixing Gun – metal bush and refitting complete :- i. WRAC / SAC unit blower motor

10

-

661.86

... More
Repairing of damaged / burnt blower motor including rewinding of Armature coil, heat varnishing, Supply & fixing Gun – metal bush and refitting complete :- ii. Water cooler/Deep Freeze/ B. Motor etc.

10

-

466.1

... More
Repairing of damaged / burnt blower motor including rewinding of Armature coil, heat varnishing, Supply & fixing Gun – metal bush and refitting complete :- III.SAC (indoor unit)

1

-

792.37

... More
Supply & charging refrigerant gas of the following Refrigeration / AC unit including supply and fixing of capillary pipe, strainer / drier, leak testing, N2 flashing etc. as required to complete the job:- i. 0.5 TR / 0.75 TR/1.0 TR Compressor (wrac).

10

-

978.81

... More
Supply & charging refrigerant gas of the following Refrigeration / AC unit including supply and fixing of capillary pipe, strainer / drier, leak testing, N2 flashing etc. as required to complete the job:- ii. 1.5 TR /2TR Compressor (WR AC)

10

-

1694.92

... More
Supply & charging refrigerant gas of the following Refrigeration / AC unit including supply and fixing of capillary pipe, strainer / drier, leak testing, N2 flashing etc. as required to complete the job:- iii. g1.5 TR / 2 TR Compressor (SAC)

5

-

1779.66

... More
Supply & charging refrigerant gas of the following Refrigeration / AC unit including supply and fixing of capillary pipe, strainer / drier, leak testing, N2 flashing etc. as required to complete the job:- iv. Water cooler / Deep Freeze.

5

-

978.81

... More
Supply & charging refrigerant gas of the following Refrigeration / AC unit including supply and fixing of capillary pipe, strainer / drier, leak testing, N2 flashing etc. as required to complete the job:- v. Refrigerator.

1

-

820.34

... More
Repairing of sheet metal body & structure of different type, model, capacity of Water cooler/Refrigerator/ Deep Freeze & AC. All sheet metal jobs to be done by 20 SWG GI sheet & MS angle per original size, shape where it will be fitted. Rate incl.2 coats approved make & brand synthetic enamel paint with 1 coat Red Lead primer as follows :-

-

-

-

... More
a. For water cooler (upto 80 lts. capacity) :- (I) Repairing portion with volume more than 75 % of body.

1

-

2097.46

... More
a. For water cooler (upto 80 lts. capacity) :- (II) Repairing portion with volume above 50% upto 75%

1

-

1771.19

... More
a. For water cooler (upto 80 lts. capacity) :- (III) Repairing portion with volume between 30 % to 50% of body.

2

-

1165.25

... More
a. For water cooler (upto 80 lts. capacity) :- (IV) Repairing portion with volume less than 30 % of body.

1

-

932.2

... More
a. For water cooler (upto 80 lts. capacity) :- (V) For Cabinet & body of WRAC unit :- I.Repairing portion with volume more than 70% of body.

10

-

1305.08

... More
a. For water cooler (upto 80 lts. capacity) :- (V) For Cabinet & body of WRAC unit :- II.Repairing portion with volume between 40% to 70 % of body.

10

-

932.2

... More
a. For water cooler (upto 80 lts. capacity) :- (V) For Cabinet & body of WRAC unit :- (iii) Repairing portion with volume less than 40% of body.

10

-

652.54

... More
a. Repairing and minor sheet metal job / patch work for all type of mode Refrigerator / Air conditioner unit.

50

-

169.49

... More
b. Supply and fixing wooden frame (made by 2” X 4” Sal wood) in place of existing broken / damaged frame including installation & electric connection complete.

10

-

1058.47

... More
c. Supply and fixing wooden frame (made by 2” X 4” Sal wood) including wall / grill cutting, plastering and allied work to complete the proper installation of any make & capacity WRAC unit with electric connection complete.

10

-

1864.41

... More
d. Installation of WRAC unit in place of existing other make unit with allied work and electrical connection complete.

1

-

2966.1

... More
e. Dismantling of Hi-wall / Floor mounted SAC machine & re-install the same at new location including necessary materials , refrigerant gas, bracket etc. complete in all respect for satisfactory performance of AC.

4

-

4194.92

... More
A. Replacement of internal electrical wiring of RAC / Water cooler / Refrigerator / Deep Freeze unit including necessary, Brass terminal clip, connector, insulating tape and connection complete.

2

-

466.1

... More
B. (i). Replacement of Door gasket only of Water cooler.

2

-

279.66

... More
B. (ii) Replacement of Magnetic Door gasket only of Refrigerator / Deep Freeze.

2

-

326.27

... More
C. Replacement of body insulation of RAC unit with necessary pasting materials and related work complete in all respect. i. 50% and above of total insulated area.

30

-

372.88

... More
C. Replacement of body insulation of RAC unit with necessary pasting materials and related work complete in all respect. ii.Less than 50% of total insulated area.

20

-

186.44

... More
Lifting and shifting charges of WRAC / Water cooler / Refrigerant / Deep Freeze for delivery after repairing the unit. , overhauling unit)

100

-

186.44

... More
Routine checkup, Deep cleaning with water (including back cover) & servicing of WRAC / SAC / WC / Refrigerant / Deep Freeze an instructed by Engg. In Charge.

900

-

211.87

... More
Breakdown call attending of any type, make and capacity Refrigerator & Air conditioning unit as details below:- i. Attend but failed to start & run.

80

-

37.29

... More
Breakdown call attending of any type, make and capacity Refrigerator & Air conditioning unit as details below:- ii. Attend rectified the fault & successfully completed the job.

300

-

93.22

... More
Breakdown call attending of any type, make and capacity Refrigerator & Air conditioning unit as details below:- iii. Attend, made it ok & servicing the unit.

100

-

102.54

... More
Through scraping, cleaning & painting of WR AC unit, protective grill, case by paint 1 coat of Berger Red Lead primer (Paint should be approved make)

40

-

233.05

... More
Supply and fixing of WR AC unit water tray (made of 20 SWG GI sheet) with adequate size outlet vent.

50

-

745.76

... More
Providing of suitable waste water drain line (made by PVC water pipe & of approved brand) on the wall by saddling 1 Mt. apart including necessary attachment to complete the job. i. 12 mm PVC pipe line

150

-

27.97

... More
Providing of suitable waste water drain line (made by PVC water pipe & of approved brand) on the wall by saddling 1 Mt. apart including necessary attachment to complete the job. ii. 19 mm PVC pipe line

120

-

32.2

... More
Fixing of waste water tray of RAC including drain line pipe.

100

-

46.61

... More
Supply and fixing of the following Electrical accessories :- i. 6-10 A , three pin plug top (Anchor)

4

-

46.61

... More
Supply and fixing of the following Electrical accessories :- ii. 16-20 A , three pin plug base (Anchor)

4

-

69.49

... More
Supply and fixing of the following Electrical accessories :- iii. Single core flexible copper wire 2.5 sq. mm FRLM(Finolex) (180 mtr)

1

-

1864.41

... More
Supply and fixing of the following Electrical accessories :- iv. Single core flexible copper wire1.5 sq. mm FRLM (Finolex)(180 mtr.)

1

-

1398.31

... More
Supply, fitting and commissioning of AC / SAC’s condensing unit (Copper tube as per sample design) including Capillary tube , strainer & Refrigerant Gas charging to set right the following AC to work satisfactorily. (i) 4.5 TR Tower AC( CAM center)

1

-

22881.36

... More
Repairing of defective / burnt compressor after dismantling including replacement of motor winding, big & small end bush, suction & discharge reeds, compressor oil and re – installation of the same for the following (incl. Gas charging, leg rubber, clip, connector etc.) :- I. 4.5 TR Tower AC( CAM center)

2

-

7627.12

... More
Repairing of damaged / burnt blower motor including rewinding of Armature coil, heat varnishing, Supply & fixing Gun – metal bush and refitting complete :- I. 4.5 TR Tower AC( CAM center)

1

-

2118.64

... More
Supply and fixing of blower motors (Crompton Greaves / Universal / DLF) for the following :- (i) 4.5 TR Tower AC( CAM center)

1

-

2966.1

... More
Any work to be done at site on emergency basis in connection with AC / Cooler / Deep Freeze / Refrigerator which is not a part of the Schedule will be executed as and when required. (Rates will be ascertained on the basis on rate analysis as per prevailing market rate/ submission of original bill ) and payment will be made as per actual work at site duly supported by relevant papers (eg. Cash memo/ bills etc. 10 % profit will be given on the cost of original bill )

1

-

25423.73



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.