Haldia Development Authority Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Haldia Development Authority - HDA Tender

Works
Eprocure
Opening Date25 Jul 2018
Closing Date7 Aug 2018
Tender Amount₹ 43,70,855 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Installation, Testing, Commissioning of LED Street Light Set 90 W (+/-5% for each set) in Moyna Panchayet Samiti under Tamluk Sub-division, Purba Medinipur.

69

-

-

... More
Supplying of looping cable box - 250mm (H) x 200mm (W) x 100mm (D) made of 1.6MM duly hot deep galvanized sheet and 2 nos. x 25 mm x 6 mm G.I. Clamp complete with bolts & nuts etc. as required for fastering looping cable box - with the pole including providing drilled holes for cable entry and street light wiring & comprising of 1 x 1A SPMCB to be placed on a Din channel and 1 x 4 Way/150 A Cable Terminal as required.

69

-

-

... More
Supply and fixing of Pole numbering Sticker (5" X 3") at the street light pole.

69

-

-

... More
Lifting of the running U G Cable to the looping cable Box of Street light pole, up to the top of the muffing above the top of the ground level by drawing through 40 mm diameter rigid PVC pipe and tiding the same by no 10 SWG G I wire with the pole including supply of superior Quality PVC pipe & wire & filling the top of the pipe/pipe hole with bitumen and neat cementing properly (average run- 1.5 M/run X 2 runs per pole. Including the supply of PVC Pipe)

69

-

-

... More
Connection of luminaire with 3C X 1.5 Sqmm pvc insulated FR copper conductor (ISI marked) through poles from looping box to light fittings as required.

69

-

-

... More
Supply and Installation of HDA printed logo suitable 15"×9" on GI Octagonal/Tubular Pole (2 Nos logo per pole), on brick foundation of meter box, feder pillar box

162

-

-

... More
Laying of Cable by Jack push method through micro tunneling 2.0-3.0 M deep under local ground level / surface of the road with excavation of double earth pit 1400×600×2000-3000 mm, laying of pipe, refilling and ramming of soil in earth pit, restoration of road surface etc (Excluding the supply of GI Pipe). Individual jack push length may vary up to 6.0 M.

6

-

-

... More
Laying of Cable by Jack push method through micro tunneling 2.0-3.0 M deep under local ground level / surface of the road with excavation of double earth pit 1400×600×2000-3000 mm, laying of pipe, refilling and ramming of soil in earth pit, restoration of road surface etc (Excluding the supply of GI Pipe). Individual jack push length may vary 6.0 to 12M.

2

-

-

... More
Laying of Cable by Jack push method through micro tunneling 2.0-3.0 M deep under local ground level / surface of the road with excavation of double earth pit 1400×600×2000-3000 mm, laying of pipe, refilling and ramming of soil in earth pit, restoration of road surface etc (Excluding the supply of GI Pipe). Individual jack push length may vary 12-18 M.

1

-

-

... More
Supply and fixing of 900 X 600 X 300 mm Meter Box of minimum 1.6 mm G.I sheet with weather and dust proof, outdoor type having top canopy, sides having Louvers for ventilation, double door, locking arrangement, four legs of the meter box (G.I. flat 50x6x150mm) with 63 Amp, 220 volt, SP MCB-3nos. for isolation purpose & necessary assembling. Installation of the meter box to be done by the earth cutting, brick soiling and cc foundation as required & sand filling, ramming and muffing around the feeder pillar box by brick and cement mortar work as per the direction..

2

-

-

... More
Supply of Feeder pillar panel of size 900 X 600 X 300 mm made of minimum 1.6 mm G.I sheet with weather and dust proof, outdoor type having top canopy, sides having Louvers for ventilation, double door, locking arrangement, four legs of the feeder pillar panel (G.I. flat 50x6x150mm), with 40Amp Cu bus bar arrangement(R, Y, B and N), necessary cu power and control cable wiring inside the panel and necessary following assembling. (Consisting of following installations in the panel) i) 40 Amp, 230 Volt, SPN MCB (ISI mark)- 1 No, ii) 32 Amp, TP, 240 Volt AC coil contactor (ISI mark)-1 nos, iii) 220-240Volt AC Digital 24hr timer (ISI mark)-1 nos, iv) 10 Amp SPMCB of 10 ka breaking capacity (ISI mark)-4 No, v) 220 volt AC LED Indicator lamp -1 No, vi) Feeder pillar illumination lamp & switch (ISI mark)-1 Set, vii) 0-300 V AC Analog Voltmeter with selector switch (ISI mark)- 1 Set, viii) Auto /Manual Switch-1 No, ix) Power connecter-1 Set, x) Detachable gland plate-1 No, Installation of the feeder to be done by the earth cutting, brick soiling and cc foundation as required & sand filling, ramming and muffing around the feeder pillar box by brick and cement mortar work as per the direction.

2

-

-

... More
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly (a) Upto 9.0 mtr. Size 0.6x0.6x1.70 mts

69

-

-

... More
Supply & fixing of GI earth Spike (1830 X 20 mm)

77

-

-

... More
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc( 0.35 sqm per pole x 70).

24.15

-

-

... More
Painting the vertical end faces of posts, wheel guards or railing or parapet with alternate bands of different colours as directed by the Engineer-in-charge with approved synthetic enamel paint( 0.35 sqm per pole x 70) (b)Two coats.

24.15

-

-

... More
Supply and delivery of 1.1 KV grade 4 C X 16 Sq mm XLPE insulated and pvc sheathed aluminum armored Cable. As per IS 7098. (MESCAB/KEI Industries/Havels India Limited/Gloster cable)

2950

-

-

... More
Laying of one No. cable upto 35 Sq mm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per meter, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.

885

-

-

... More
SUPPLYING, LAYING OF HDPE PIPES, RATES OF HDPE PIPES GRADE - PE80 (PN-10.0), OD-50mm and ID- 40.8mm

1798

-

-

... More
Laying only Cable up to 50 sq.mm through existing RCC/Hume/ GI /HDPE Pipe/open masonry trench for single, 2, 3, 3½ & 4 core

1858

-

-

... More
Supply & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing materials as required.50 mm dia

60

-

-

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armored cables as below: i) 4 core X 16 sq mm

150

-

-

... More
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. i) 4 core X 16 sqmm

150

-

-

... More
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work

50

-

-

... More
Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts, For Soft Soil.

2

-

-

... More
Excavation of soil for installation of Earth Electrode and filling & ramming. (a) For Soft Soil

2

-

-

... More
Providing and fixing typical citizen information board constructed with BFS, PCC, 250 mm & 125 mm brick wall (1:4) with necessary 15 mm thick plastering (1:4) & rule painting, including supply & fixing of white marble stone (1100mm X 800mm X 18mm) with black colour engraved lettering as per the enclosed drawing.

7

-

-

... More
Supplying and fixing Sheet steel Main Switches on flat iron frame on wall, 32Amp, 240V DP with fuse on L&T

4

-

-

... More
Connecting the equipments to earth bus bar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. As required and mending good damages, 8 SWG

178

-

-

... More
Connecting the equipments body to earth bus bar including S & F 25 mm x 6 mm galvanized (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.

12

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.