Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_PMPB_11521_1Bid Award Id
ViewTender No
02A/GP/PIU/BRIDCUL/PB/2017Tender Authority
Uttarakhand Disaster Recovery Initiative ViewPurchaser Address
-Website
http://http://ukdisasterrecovery.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Bed forward with Mattress (100mm) (2200mm L x 900mm W x 600mm H.)
Providing and placing premium quality semi fowler bed -
I. Overall size shall be minimum 2200mm L x 900mm W x 600mm H.
II. It shall be a semi functional bed with fixed lower section and adjustable back rest. Bed frame shall be made of 1.6mm thick MS ERW rectangular tube of 30mm x 60mm and 1.6mm thick MS ERW round tube of dia 30mm.
III. The lying surface frame shall be made of 1.6mm thick MS ERW round tube with minimum dia 25mm. The surface shall be 1mm thick CRCA sheet and shall have mattress retainer to define the position of mattress. Backrest shall have provision of elevation of 65-70 deg.
IV. Head and leg boards shall be made of 1.6mm thick MS ERW round tube with minimum dia 31mm for main frame, 19mm dia for vertical tubes and 25mm for cross connector tube. Minimum 3 nos of vertical tubes shall be there.
V. Thread rolled EN8 lead screw, with ACME threads and 6mm pitch shall be used to give good strength and ease in operations.
VI. Snap fitted PPCO handle lever shall be used with handle body so as to keep it in folding position when not in use.VII. Castors shall provided with 125mm wheel dia and 22mm stem dia made of high endurance metal with dual locking arrangements which shall be placed diagonally.
VIII. The bed shall have mosquito net pole holder and IV pole holder for provision of mounting these accessories, if required.
IX. Finish shall be epoxy polyester powder coated in white.
X. It shall have safe patient load capacity upto 135kgs.
XI. The mattress size shall be 1965mm L x 830mm W x 100mm thick. Backrest section shall be at 770mm, foam density shall be 45 kg/m3 and hardness of 45 at 25% compression as per IS:7888. It shall be upholstered with heavy helium anti-microbial and fire retardant cover. It must be fitted exactly onto the bed.
XII. The color shall be decided at the time of finalisation of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement.
11
-
-
... More
BED SIDE LOCKER EXECUTIVE
Providing and placing premium quality bed side locker -
I. Overall size shall be minimum 400mm W x 400mm D x 825mm H
II. It shall have one cabinet and one shelf. Top shall be made of 0.8mm thick SS 304 and cabinet shall be made of 1mm thick CRCA sheet with provision of ventilation holes, ABS recessed handle and cam lock on door. Cabinet size shall be minimum 340mm W x 390mm D x 300mm H.
III. Structure shall be made of 1.6mm thick MS ERW square tube of 25mm. PVC nitrile shoe should be provided on legs to avoid the metal contact with floor.
IV. Finish shall be epoxy polyester powder coated in white for MS and buffed mirror finish for SS.
V. The color shall be decided at the time of finalisation of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement.
11
-
-
... More
EXAMINATION TABLE ON RATCHET WITH NO STORAGEwith Mattress (30mm)
Providing and placing examination table –
I. Overall size shall be 1830mm L x 600mm W x 850mm H.
II. It shall be made of sturdy structure and the backrest shall have ratchet mechanism for tilting the backrest.
III. The leg frame and intermediate/connector frame shall be made from 1.6mm thick MS ERW square tube of 30mm.
IV. Top shall be made of 1.2mm thick MS sheet, ratchet shall be made of 5mm thick MS plate with 3 position adjustment of 0, 15 & 30 deg. The size of ratchet shall be 450mm L x 600mm W.
V. Finish shall be epoxy polyester powder coating in white.
VI. It shall have safe patient load up to 135kgs.
VII. Leg shoe shall be made of nylon 6 to avoid wear and tear.
VIII. The color shall be decided at the time of finalization of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement.
IX. Mattress size shall be 1830mm L x 300mm W x 30mm thickness, with headrest section of minimum 469mm L and fixed section of minimum 1361mm L. Foam density shall be 40 kg/m3. It shall be upholstered with heavy helium anti-microbial and fire retardant cover in navy blue color.
X. The color shall be decided at the time of finalization of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement.
9
-
-
... More
BED SIDE SCREEN Four Fold Providing and placing premium quality 4 equal fold bed side screen -
I. Overall size shall be minimum 2625mm L x 640mm W x 1700mm H
II. Fixed frame shall be made of 1.2mm thick MS ERW tube of dia 25mm to provide hinging to movable frame. The total width shall be minimum 1075mm.
III. Movable frame shall be made of 1.2mm thick MS ERW tube of dia 19mm, it shall have hinges. The total width shall be minimum 775mm.
IV. The leg frame shall be made of 1.6mm thick MS ERW square tube of 30mm.
V. Castors shall be of dia 50mm.
VI. The screen shall be casement fabric in green color which shall be opaque for providing modesty. Supplied with hooks & springs with curtain cloth. All mild steel components should be thoroughly pre-treated chemically to remove rust and foreign matter like Grease, Oil etc. by dip tank process.
VII. Finish shall be epoxy polyester powder coating in white.
VIII. The color shall be decided at the time of finalisation of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement.
11
-
-
... More
S.S. Revolving Stool / Chair with S.S
Providing and placing SS top round stool -
I. Overall size shall be minimum base dia 530mm x 470mm-650mm height
II. Non-corrosive SS top of 1mm thick plate made of SS 202 sheet with round dia of 300mm shall be mounted on four leg base with screw nut mechanism for height adjustment. MS seat base shall be welded construction made up of MS ring, rectangular tube & mounting plate. Height adjustment of seat base shall be done using screw made of EN8 OD22.
III. Legs shall be made of 1.6mm thick MS ERW tube of dia 25mm press formed to give round and clean look and shall be welded with round hub which shall be made of 2mm thick tube of dia 38mm for bush mounting.
IV. It shall have plastic bush made up of moulded nylon 6 to avoid metal and surface friction.
V. Finish shall be epoxy polyester powder coated for MS and buffed mirror finish for SS.
VI. It shall have safe working load capacity upto 135kgs.
VII. The color shall be decided at the time of finalisation of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement.
14
-
-
... More
Over bed Trolly
Providing and placing premium quality Over bed trolley-
I. Overall size shall be minimum: 1000mm L x 350mm W x 900mm H, with maximum safe working load of 20kgs.
II. Structure shall be made of 1.2mm thick ERW round tube with 19mm dia and 25mm dia so as to provide the sturdy structure.
III. Top shall be made of 18mm thick wooden laminate with precious peach wooden texture.
IV. Castors shall be made of plastic with 50mm dia for the ease in movement.
V. Finish shall be thermosetting epoxy polyester in RAL white powder and precious beach wooden texture for the laminated top.
VI. The color shall be decided at the time of finalization of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement.
8
-
-
... More
SALINE STAND
Providing and placing premium quality saline stand-
I. Overall size shall be minimum: 690mm Dia x Adjustable Height from 1568mm – 2121mm, having maximum load capacity of 3 kg per hook for saline bag.
II. It shall be mounted on portable four pronged base with castors, shall have a telescopic tube for height adjustment and four hooks for saline bag mounting. Telescopic tube shall have plastic guide bush made of nylon 6 at the bottom which provided the smooth linear motion during height adjustment. Bush should also help to stop the telescopic tube at predefined height so that telescopic tube could not hit the hand in case of accidental fall, III. Bottom frame shall be made of 1.6 mm thick MS sheet to give round base and clean look with dia 30 mm MS sheet for bush mounting of castors,
IV. Fixed tube shall be made of 1.6mm thick MS ERW tube with 31 mm dia, V. 1.6mm thick Buffed mirror finish SS 204 tube shall be used with 19mm dia for the telescopic function to provide smooth function without wear and tear, 4 saline hooks for hanging saline bags shall be made from 8mm dia SS 202 sheet,
VI. Nylon 6 screw knob with MS toughened nickel plated threaded stud shall be used for adjusting the height of adjustable tube and locking it in its position,VII. Accessory mounting cover shall be made from 2mm thick nylon 6 of ribbed section and plastic parts shall be provided to cover accessory joints,
VIII. Castors shall be provided with 50mm wheel dia and threaded stem made of high endurance plastic injection moulded.
IX. Finish shall be anti microbial and thermosetting epoxy polyester, formulated to fulfill the requirements of bacterial protection. Powder coated parts shall be in white, SS parts shall be in buffed mirror finish.
ISO Certification.
16
-
-
... More
Foot operated suction Machine
Providing and placing Portable and non string pedal operation
2. Open end glass/fibre jar of about 1000 ml.
3. Piston type pump
4. Out right vacuum 600 mm Hg
5. Shall have self sealing lids The color shall be decided at the time of finalisation of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement.
CE/EC Marked/US FDA/ISO certification
3
-
-
... More
Oxygen Concentrators
Providing and placing Oxygen Concentrator
i. Should have flow from 0-5 litres per minute with variation of 0.5 LPM.
ii. Purity of oxygen should be 93% +/- 3%.
iii Should have built in nebuliser.
iv. Flow meter 0-5 LPM should be illuminating during night.
v. Should level should not be more than 50 db(A).
vi. Should have high temperature indicators with alarms, machine should shut off in case of high temperature.
vii. Should have power failure alarm.
viii. Should have oxygen purity indicator.
ix. Should have built in castors for easy mobility.
x. Should have digital LCD timer showing aggregate run time of the machine and also time counter since machine put on for use.
xi Provision in timer for setting the time of use with ten minute variation, and machine should shut off automatically after set timing.
xii. Should have inbuilt box for keeping accessories like mask/cannuals/power card/cover and manual etc.
xiii. Air suction inlet filters should be on both the sides. 05 (five) spare filters should be provided with equipment.
xiv. Low Power Consumption should not be more than 400 Watts.
xv. Power Supply 220-240 VAC; 50 Hz.
xvii. Should be able to function on invertors/generator in case of power failure. xviii. Should be provided with Cover, Voltage Stabilizer, Cannula/mask, Humidifier and descriptive working manual. xiv. The unit should be ISO/BIS/ISI Certified. The color shall be decided at the time of finalisation of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement. CE/EC Marked/US FDA/ISO certification
5
-
-
... More
Nebulizer piston type
Providing and placing Nebulizer with piston type compressor Aerosol particles in range 1 to 5 micron
Flow rate at least 4 ml/minute
Liquid/medication container at least 20ml
Power requirement 220 V, 50 Hz The color shall be decided at the time of finalisation of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement.
CE/EC Marked/US FDA/ISO certification
6
-
-
... More
Radiant Warmer
Providing and Placing Infant Radiant Warmer with a radiant heating source intended to maintain the thermal balance of an infant by direct radiant of energy in the infrared region of the electromagnetic spectrum.
i. It should be microcontroller based radiant warmer with manual and servo options.
ii. It should have facility to display skin set, skin observed temperature in degree C and heat power separately.
iii. Should have user friendly touch panel control.
iv. It should have ceramic or quartz infrared or calrod heater.
v. It should have audiovisual alarm facility for overheating beyond set temperature range.
vi. It should have alarm facility for patient temperature less than or greater that the required temperature i.e. above or below the set range. Machine should sense the skin probe failure and cut off the heater.
vii. Warmer head should be rotable in different direction, so as to allow taking X-ray.
viii. It should have alarm for probe failure, power failure, system failure and heater failure.
ix. Observation light of 90 to 100 foot candles or 1000 Lux (Color temperature range 3700K to 5100K) should be provided for inspection.
x. Battery back up for Power failure indication during power fail.
xi. The desired temperature range from 25 to 40 degree C and settable temperature can be from 32 to 38 deg C.
-
-
-
... More
xii. The resolution should be 0.1 degree C and accuracy should be 0.2 o C.
xiii. Should have a facility to lock the keyboard to avoid unwanted user modification of the set parameters.
xiv. The height of the warmer should be adjustable for different types of bed.
xv. It should have separate bassinet trolley, bed should be tiltable and have provision for x-ray cassette holder, Mattress foam density should be minimum 25Kg/cm3, transparent collapsible side walls easily detachable for cleaning. Mattress size should be minimum 20”X30”.
xvi. Should have a feather touch operation with large digital display and comprehensive alarms. Control panel should be liquid proof and allow easy and hygienic disinfection.
xvii. Manual mode can adjust Heater Output 10-100%, with 10% increment , and auditory and visual alarm shall be given at least every 15 min.
xviii. In manual mode, heater cut off/ switch off, if the maximum irradiance at any point of the mattress area exceeds a total irradiance level of 10mW/cm2 (between 10 to 30 minutes).
xix. Bed should be about 80-100cms from the floor and 80-90 cms from the heat source.
xx. Should have lockable castor wheels.
xxi. Green indicator light shall be provided to indicate the warmer is ready for normal use.
xxii. Markings on the bassinet and X-Ray cassette holder is mandatory to enable proper positioning of the baby while doing the X-Ray.
-
-
-
... More
xxiii. The side of the drop down sides should be such that it is 5” above the mattress surface and should be at least 6mm thick, clear and transparent.
xxiv. If there is more than 60% heater output for 10 minutes it should cutoff with alarm.
xxv. For the purpose of cable management there should be at least two number of tubing ports (edges covered by silicon rings) on the side walls. The height of the side walls should be minimum 110 mm over the mattress.
xxvi. X-Ray cassette tray should be at least 750x350mm and should adopt up to 20mm thick X-Ray cassette.
xxvii. The bay bed should be crevice free for ease of cleaning, infection control. xxviii. The mattress used should be of biocompatible material.
xxix. Thermistor based skin temperature probe should be small in size not more than 10mm diameter and 3-4mm thick to fix the probe firmly on the infant. Baby contract material should be biocompatible as per ISO 10993 standard requirement. It should be insulated on one side and have well conducting non-rusting, non reacting metallic surface on the other side. Probe wire should be pliable, thin and soft. The attachment site of the probe with the wire should also be pliable and no stiff.
xxx. The color shall be decided at the time of finalisation of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement.
CE/EC Marked/US FDA/ISO certification
2
-
-
... More
STRETCHER on Trolly
Providing and placing premium quality stretcher on trolley -
I. Overall minimum size shall be 2000mm L x 650mm W x 825mm H
II. Stretcher size shall be 1800mm L x 585mm W. It shall be removable mounted on a sturdy trolley having castors for ease of movement, it shall be made of 1.6mm thick MS ERW tube of dia 25mm. The top sheet shall be 1.2mm thick CRCA contour shaped to provide safety to patient while in use. Holder shall be there to hold it in position on to the trolley.
III. It shall have 2 nos. diagonally opposite I.V. pole holder made of MS which can hold I.V. pole of mounting stem dia 12.5mm.
IV. The trolley shall be made of 1.6mm thick MS ERW tube of dia 31mm and 25mm. The horizontal tubes shall be 1.2mm thick of dia 25mm.
V. Castor wheels shall be diagonally lockable with dia 200mm.
VI. Finish shall be epoxy polyester powder coating in white.
VII. Knock down construction.
VIII.It shall have safe working load capacity upto 135kgs.
ix.Upholstered fixed Top covered with washable plastic material , Flame Retardant
X. The color shall be decided at the time of finalisation of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement.
3
-
-
... More
Emergency Scoop Strecher
Providing and placing premium quality Emergency Scoop Strecher -
I. Overall minimum size shall be 2000mm L x 430mm W 1. The stretcher should be designed allowing coupling and uncoupling of any of the
ends and gently scoop up the patient using the two scoops of the stretcher.
2 The stretcher should be telescopic to accommodate the tallest patient and should
be folded for compact storage.
3 The frame should be made of high quality anodized aluminum and blades should be
made up of extruded aluminum.
4 The scooping blades should be fixed with aluminum frame by interposition of alloy
fusions.
5 It should have an integrated handle to select the length of the distal part of the stretcher.
6 The scoop stretcher should be easily foldable in one swift movement.
7 It should have easy locking and unlocking nylon restraint belts to fix the patient to the
stretcher.
8 The fixture should have two points of holding the stretcher but only one point of fastening. The fastening point should have a locking system operated by single hand with lockable twist with locking arrangement to protect any inadvertent use.
9 The device must comply with Medical Device Directives (93/42/EEC) having the CE mark along with the four-digit code from the certifying agency.
3.7.10 the device must be manufactured in an ISO 13485 certified facility
The color shall be decided at the time of finalisation of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement. ISO Certified.
3
-
-
... More
WHEEL CHAIR
Providing and placing of foldable wheel chair -
I. Overall size shall be minimum 790mm L x 600mm W x 870mm H
II. Foldable frame structure shall be made of 1.2mm thick A3 carbon steel tube of dia 22mm with chrome finish. Cross bars shall be made of 1.2mm thick A3 carbon steel tube of dia 25mm.
III. Rear wheel shall be 600mm Solid Mag wheels with alloy in the rim and solid rubber lining for the wheels for strong and sturdy performance. It shall be made of PA polymer and outer with solid rubber.
IV. Front wheel shall be 200mm HUB made of PA polymer and outer with Solid rubber.
V. Armrest shall be made of PU molded arms for better arm support. Holder base shall be made of ABS polymer. Leatherite strap shall be provided for calf rest.
VI. Cushion leatherite seat, VII. Intgrated handrim shall be provided to drive the wheel chair. It shall be made of 1.2mm thick A3 carbon steel tube of dia 16mm with chrome finish. Handles shall be moulded PVC for better grip.
VIII. Adjustable alluminum (ZL104) die cast foot rest with up down and swiwel type adjustment shall be provided.
IX. Hand brakes shall be provided to lock the wheelchair at desired location.
X. Provision for extended base with Moulded Plastic (PE PLASTIC) grip to lift the wheelchair front to overcome obstructions while maneuvering shall be there.XI. The chair shall have anti rust chrome finish.
XII. It shall have load bearing capacity upto 100kgs.
XIII. The color shall be decided at the time of finalisation of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement.
3
-
-
... More
Weighing Scale for Adults
Providing and placing Scale for Adults
Capacity-5-150kg.
Graduation-100gr.
Precision-25 gr.
Washable surface. The color shall be decided at the time of finalisation of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement.
ISO certification
4
-
-
... More
Bio Medical Waste Bins
Providing and Placing Bio Medical Waste Bins
Colour code - Red (recyclable waste), Yellow - incinerable
waste, Black - general waste, Paper - blue dustbins
Size
Height - 18”
Circumference - 12” Square
Volume should be approximately 20 liters
Lid - with foot operated lid with silicone seal
Silicone/ Teflon Collar for affixing appropriate coloured bag
inside the dustbin
Material - fibreglass of appropriate colour thickness 8 mm
(minimum)
It should bear biohazard label
4
-
-
... More
Minor O.T. Table for General Surgery Providing and placing Minor O.T. Table for General Surgery Overall minimum size 72'' L x 20''W x 32'' H
CRCA Tubular frame minimum 18 Guage castor of 100mm dia.
Height adjustment by crank mechnism with lever handle
The table top shall be made by SS 304 grade in 20 guage in five section.
All positions Viz, Straight, Trendelenburg & reverse Trendelenburg positions, Kidney bridge, lithotomy position.
Fine finished
1
-
-
... More
Examination LED OT Light To provide pure white cool light with variable light intensity upto
50,000 Lux for minor OT’s; critical care and emergency areas.
2. The light should be on a floor stand.3. Extremely flat, compact dome with two handles with innovative with
minimum 12 LED's.4. Having a tubular vertical support with counter balanced spring arm
(approx. reach 6.5 ft.) moving up and down and having mobile antistatic lockable 4 wheels stand.5. Light head made of durable polycarbonate /aluminum and having one sterilizable handle.6. Light head having smooth and clean surfaces that are easy and safely to clean.7. Electrical commutators to be present to provide continuous rotation
of the light-head and is rotatable by 300deg.8. Light pattern size to be fixed and should be min. 6" spot.9. No heat emission through IR radiation. 10. Having push button type control for light intensity variation between 20,000 to 50,000 Lux.11. Colour temperature : between 4000k- 5500k 12. Colour rendering index (CRI) of minimum 9013. Life span of main light source not less than 30,000 hours14. Supply voltage: 240 VAC, 50 Hz Single phase easily connectable to hospital emergency power supply in the event of AC power supply failure.15. The unit should be supplied with a minimum warranty of 5 yearsafter successful installation. The warranty must cover each and every part of the equipment16. The LED OT Lights should be having US-FDA / European CE certification17. The equipment should be designed to comply with existing international standards in terms of safety and performance i.e.ISO9001/ISO 13485, IEC60601 and UL Standard. Having EMI/EMC testing EN60601-1-2-2001-electromagnetic compatibility The color shall be decided at the time of finalisation of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement. CE/EC Marked/US FDA/ISO certification
3
-
-
... More
Electric Suction Machine
Description of Function: To extract fluid from the body during surgery or emergency treatment.
• Shall have Crompton Greaves/ American Universal/ GEC Motor of minimum ¼ H.P Capacity.
• The machine should be portable on four wheels and handle for transportation.• The Suction pump should be oil immersed fitted on Motor shaft. • To facilitate maintenance the cover of machine should be easily to open from the top & sides.• The suction machine should be capable of producing minimum vacuum of 500 approx mm Hg, which should be adjustable and monitored by vacuum gauge of suitable range. The suction capacity should be 15 litres per minute and can be regulated.
• It should have two bottle of 2 litters ( As per requirement ) with synthetic rubber lids. The bottle shall be fitted with the arrangement to prevent overflow of fluid.• ON/ OFF switch and power indicator should be available • Body material: Base, top & panel made of rust proof and corrosion resistant moulded ABS. Jar/Bottle material: Autoclavable polycarbonate. • Inbuilt maintenance free battery. Battery backup upto 60 minutes on charge.
• Unit should be weighing approx. Maximum 20 Kg. • Provided with cable for ambulance/ car use. Supplied With:Electrical Instruments SterlizerPower cable of 5 meter length along with one 3 pins 15 amp. Plug-01 The following spares per machine are also requird:-I. Bottles 2 Nos.II. Lids 2 NosIII. Rubber Seals 2 Nos.IV. Blades 2 Nos.V. Suction Tubing set 1 NoPower Supply:• Power input to be 220-240AC, 50Hz fitted with Indian plug.• A fuse or a resettable circuit breaker of an appropriate capacity should be incorporated for protection of motor.• Manufacturer should be ISO/ISI/BIS certified for quality standards The color shall be decided at the time of finalisation of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement. CE/EC Marked/US FDA/ISO certification
3
-
-
... More
Electrical Instruments Sterilizer
Providing and placing Electrical Instruments Sterilizer
Overall minimum size 430mmx200mmx200mm
1. The body shall be made by minimum SS 202 Grade having minimum thickness of 18 Guage.
2. the body shall be seamless and jointless.
3. Should be operated in mains 220 – 240 V ac 50 Hz input power supply. The color shall be decided at the time of finalisation of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement.
7
-
-
... More
New Bourne Electric Weighing Machine
Providing and placing premium quality bourne weighing machine-
I. Overall size shall be minimum: 500mm Lx 200mm W x 80mm H. It shall also have the facility to measure the length of baby. II. Machine shall have minimum measuring capacity of 25 grams and maximum measuring capacity of 20 kilos with accuracy of 5 gm and with zero calibrations.
III. Machine shall be able to hold the measured value irrespective of the baby movements. IV. Machine shall have electronic damping facility for eliminating the reading fluctuations caused due to baby movement. LED display shall be provided for easy reading.
V. Weighing pans shall be suitable for weighing new born babies and the construction shall not the baby to slip from tray. Tray shall be made of SS/ fiber glass/acrylic.
vi. Should operate on input supply 200 to 230 Vac, 50 Hz. The color shall be decided at the time of finalisation of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement.
5
-
-
... More
X-Ray Machine with assocceries
Providing and Placing X -Ray machine 100 mA (LF) with all assocessories I X-RAY GENERATOR
i Type: High frequency 4KW or more
ii KV:100 or more
iii mA: 100 or more
II X-RAY TUBE
i Should be of reputed makeIII RADIOGRAPHY
i KV Range:40-110 or better.
ii mA Range: 20 to 100 or better.IV CONTROL PANELi Digital display of all radiographic parameters
ii mAs: up to 250mAs or moreiii Automatic tube over load protection.V MECHANICAL SPECIFICATIONSi Spring/Counterbalanced, ii Articulated tube armiii Easy to move and handle
iv Light beam diaphragm collimator.
v Extendable hand switch with cable for x-ray exposure.vi Integrated cassette box
VI FEATURESi The quoted model and tube should be AERB Type approved for usage up to 100mA or more. Relevant copies of the
certificate should be attached with the bid.ii Should be mounted on heavy duty casters.VII STANDARD ACCESSORIESi Light weight lead apron 0.5mm lead equivalence with thyroid guard – 1no.ii Lead apron 0.5mm lead equivalence with Thyroid guard- 1 noiii Channel type hanger each size 3 nos.iv Lead markers R, L, 0-9 and A-Z each 2 sets. CE/EC Marked/US FDA/ISO certification
1
-
-
... More
VERTICAL AUTOCLAVE 35 Ltr. Mimumum CAPACITY
Providing and Placing VERTICAL AUTOCLAVE nut locking
1.Should have a double walled construction by SS 304 Grade.
2. Should have water inlet and outlet valves.
3. Should have a water level gauge
4. Should have pressure gauges for measuring chamber pressure.
5. Should have an inner temperature indicator.
6. Should have automatic pressure control switch, safety valve and eject valve.
7. Should have joint-less silicone gasket.
8. Should have automatic low water protection (cut off with audible alarm) and should not use high voltage earthing system.
9. Should have 121ºC working temperature at 15 to 20 psi pressure.
10. Chamber volume should be approximately 300mm diameter and 500mm depth.
11.Minimum Capacity : 35 Ltr
12. Should be operated in mains 220 – 240 V ac 50 Hz input power supply.
13. Should supply minimum 2 nos of bins of suitable size.
14. System should be European CE certified or USFDA approved.
15. Three year on site warranty inclusive of all spares and Labour and bidder should also provide rate for 5 year CMC separately.
The color shall be decided at the time of finalisation of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement.
2
-
-
... More
Phototherapy Unit Phototherapy Unit SingleSurface LED Type Surface LED Type Providing and Placing Phototherapy Unit Phototherapy Unit SingleSurface LED Type Surface LED Type 1. Phototherapy should be based on advanced LED technology
2. In LED technology the irradiance should cover the entire treatment area.
3. In LED technology the irradiance should cover the entire
treatment area.
4. Irradiance level should be higher than normal blue tube lights.
5. Lamp source should be continuous tiltable to ±90 degree angle to cover the entire
treatment area.
6. System should be height adjustable with built-in non resettable timer
7. It should be supplied with a compatible trolley
8. Should work with input 200 to 240Vac 50 Hz supply.
9. Should have safety certificate from a competent authority CE issued by a notified body registered in the European commission / FDA (US)/ STQC CB Certificate/ STQC S Certificate or valid detailed electrical and functional safety test report from ERTL. Copy of the certificate/ test report shall be produced along with the technical bid. The color shall be decided at the time of finalisation of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement. CE/EC Marked/US FDA/ISO certification
1
-
-
... More
Semi Auto Biochemisty Analyzer
Providing and placing Semi Auto Biochemisty Analyzer
1. Should be microprocessor controlled general purpose bi-chromatic photometer system with at least 6 filters ranging from 340 to 630nm.
2. Temperature 37 self monitoring built-in incubation systems for temperature controlled absorbance reading.3. Light source : Tungsten/ halogen or higher grade with one additional bulb.4. Should have end point, kinetic and two point kinetic measurement modes. 5. Should have flow cell measuring device.
6. Should have inbuilt printer or External Printer to be supplied.7. Should have a measurement range from 0.001 to 2.300Abs8. Should have facility for reading results on LCD display.
9. Should have quality control – two control/test QC survey of at least 30 points, Levy
Jenny plot.10. Should have a filter half bandwidth of 10nm or lesser.11. Should have a test programme memory of 50 or more.12. Should be provided with sample carry over prevention facility.13. Aspiration should be based on Bellow/Peristaltic Pump/ Vacuum pump.
14. Should provide 500 ml of reagents for urea, S. creatine, S. bilirubin, sugar, cholesterol, and Quality control 5ml one each for normal & abnormal.
15. Should be supplied with on line pure sine wave UPS of sufficient capacity for aminimum back of 30 minutes.
16. Should be provided with calibration certificate issued by the manufacturer at the timeof installation and periodic calibration must be done during warranty / AMC period .17. Should have safety certificate from a competent authority CE issued by a notifiedbody registered in the European commission / FDA (US)/ STQC CB Certificate/ STQCS Certificate or valid detailed electrical and functional safety test report from ERTL. Copy of the certificate/ test report shall be produced along with the technical bid. 18. Sample Volume must not exceed 50μl and reagent volume must not exceed 500μl19. There should be provision for two additional filters and the rate for additional two filers must be quoted separatelyThe color shall be decided at the time of finalisation of contract and shall be approved by the Employer. The model shall be approved by the employer before procurement. CE/EC Marked/US FDA/ISO certification
1
-
-