Pey Jal Nigam Uttarakhand Tender
View past bidders for Uttarakhand Pey Jal Nigam Uttarakhand Tender
Pey Jal Nigam Uttarakhand Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date24 Mar 2025
Closing Soon8 Apr 2025
Tender Amount₹ 6,27,13,000
AI Insights
Technical
Technical
Additional Eligibility
Bid Capacity
... View More
The formula for Available Bid Capacity is: Assessed Available Bid capacity = (A x N x 2 - B) where A = Maximum value of Engineering works (Civil and/or E&M) executed in any one year during the last seven years (updated to the price level of the current financial year) N = Number of years prescribed for completion of the works for which bids are invited. B = Value (updated to the price level of the current financial year) of existing commitments and on-going works to be completed during the next years.
Technical Capacity
... View More
The required prior work experience for the bidder includes similar works completed during the last seven years. The bidder should have satisfactorily completed at least one similar work of value not less than 80% of the Estimated cost of work, or should have satisfactorily completed at least two similar works of value not less than 60% of the Estimated cost of work each, or should have satisfactorily completed at least three similar works of value not less than 40% of the Estimated cost of work each. For Civil Works, the bidder should have executed in the last seven years, a minimum of 50% of the BOQ quantity for quantity-based works, or 70% of Capacity for capacity-based works. For E&M Works, the bidder should have executed in the last seven years, a minimum of 50% of the BOQ quantity for quantity-based works, or 70% of Capacity for capacity-based works. The bidder should also have an experience of satisfactory completed automation of 2 Nos. Pumping plants in the last seven years. The average annual financial turnover of construction works worth 30% of the contract value during the immediate last three consecutive years is also required. Additionally, the bidder should have an average annual turnover of at least 19.23 Lakh in the last 7 financial years. The 2nd and 3rd Joint Venture Partner should have an average annual financial turnover of 25% of the value given in the relevant clause. The contractors shall have to produce the list of running works of similar nature, in progress, and certificate for their up to date progress and execution of the work satisfactorily. The bidder is required to submit proof of all contract agreements for which payments have been received during the last seven years.
Costs
EMD
₹ 12,54,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MDPEY_81880_1Tender No
Letter No 567/Nivida/76 Dated 20.03.2025Tender Authority
Pey Jal Nigam Uttarakhand ViewPurchaser Address
-Website
http://http://peyjal.uk.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
200 mm
1
-
-
... More
250 mm
1
-
-
... More
300 mm
1
-
-
... More
Supply of all materials, labour T&P etc. for construction of boundary wall as per departmental type design required for proper completion of work. At Almiya, Bhantad pumping stations and at main CWR (Gaira Chaura)
150
-
-
... More
Supply and fixing of 3.60 m wide main gate & 1.20 m wide wicket gate including construction of pillars as per departmental type design including supply of all materials, labour, T&P etc. required for proper completion of works.
At Almiya and Bhantad pumping stations
3
-
-
... More
Staff Quarter at Almiya PS
1
-
-
... More
Single seated Toilet with Urinal and Wash basin at Thal PS
1
-
-
... More
Excavation for pipe line trenches including lift up to 1.5 m and lead up to 30 m filling, watering and ramming of Excavated the earth into the trenches or into the sides between foundation trenches or into the plinth and removal.
-
-
-
... More
In soil mixed with shingle boulders etc. (70
%)
3850.21
-
-
... More
In soft rock (30 %)
1650.09
-
-
... More
Distribution newt work (GI pipes)
-
-
-
... More
50 mm dia
7832
-
-
... More
65 mm dia
1403
-
-
... More
80 mm dia
1413
-
-
... More
100 mm dia
2521
-
-
... More
Providing of all materials, Carting from site store to site of work, Lowering into trenches with true to alignment, Laying of MS ERW Pipes grade Yst 210, Jointing by electric welding process with proper grade of electrodes suitable for jointing of water supply pipe lines (Ador, L&T or equivalent electrodes) by cutting of pipes and making required bends by welding, completion of work with testing of pipe line etc complete.
-
-
-
... More
125 mm dia, 3.2 mm thickness (OD 141.3 mm)
1373
-
-
... More
150 mm dia, 2.8 mm thickness (OD 168.3 mm)
386
-
-
... More
200 mm dia, 3.2 mm thickness (OD 219.1 mm)
149
-
-
... More
250 mm dia, 4 mm thickness (OD 273.1 mm)
358
-
-
... More
Testing of pipe samples from authorised institute
10
-
-
... More
Providing and erecting 2.00 metre high temporary barricading at site: each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/ bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting . The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m.
50
-
-
... More
Supplying and fixing of following sizes of valves including carting the same up to site of work and fixing the same in water supply lines including cost of valves, specials, labour and T&P complete in all respect but excluding the cost of earth work and construction of chamber. Brass G.M. Valve
-
-
-
... More
50 mm dia
18
-
-
... More
65 mm dia
6
-
-
... More
80 mm dia
3
-
-
... More
Providing & Fixing D.I. D/F Sluice Valves Confirming to IS: 14846-2000 in position including all material, labourer, T&P etc complete.
PN 10:
-
-
-
... More
100 mm dia
9
-
-
... More
125 mm dia
5
-
-
... More
150 mm dia
2
-
-
... More
200 mm dia
2
-
-
... More
250 mm dia
3
-
-
... More
Supplying and Fixing of Fire Hydrant Valve IS 5290 (Flanged) Including carting the same up to site of work and fixing the same and water supply line Including the cost of valves, specials, labour and T&P Complete in all respect.
80 mm diameter
5
-
-
... More
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diaM, 160 mm bottom diaMand 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size )
, ic necessary excavation, foundation concrete 1:5:10(1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
27
-
-
... More
Constructing masonry Chamber 90x90x100 cm inside
21
-
-
... More
Constructing masonry chamber for Fire hydrant (60x60x75) cm
5
-
-
... More
Cartage of pipe and special from Rail Head to site of work complete and sand grit etc from query site.
1
-
-
... More
Providing and making house service connections from water supply distribution GI pipe line up to water meter chamber inside the property using GI pipe including supply and fixing of electrofusion saddle
,brass ferrules elbow, ball valve etc complete with earthwork, road cutting with restoration works
-
-
-
... More
New connections
1314
-
-
... More
Shifting from old connection to new
connection
1184
-
-
... More
Providing of all materials, Carting from site store to site of work, Laying & Jointing of G.I screwed pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc) in trenches with its cutting, threading and testing of pipe line etc completing. PIPE CONFORMING TO IS : 1239 (PART-1) Medium class (Class 'B'). (It will be used for those houses which are located beyond 12 meters from taping point)
15 mm dia
3552
-
-
... More
Supply of all labour, material required for restoring of existing house connection which might be damaged during excavation and also shifting all existing connection to new water supply system from existing water supply system complete as per unit estimate and directed by Engineer in-charge. 15 mm size water connections.
59
-
-
... More
15mm AMR Water Meter Class-B Multijet as per IS 779-1994 or ISO-4064-2005 CE mark IP-68 along with -(i) Walk by/Drive by Based Technology
2500
-
-
... More
Walk by/Drive by Hand Held Meter Reading Unit
2
-
-
... More
Polycarbonate Box Blue with transparent lid,must have option to seal the box, min three seal option with two iron angle to fix the box.◻
Size- length-255mm , width-210 mm,height-
190 mm
2500
-
-
... More
Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge:
Bituminous road
2718.3
-
-
... More
Dismantling of following type of road surface for laying of pipe line including sorting out of serviceable materials and disposal of unserviceable materials.:
C.C. Road
77.1
-
-
... More
Dismantling Interlocking block pavement Road
222
-
-
... More
Construction of Un-reinforced ,Cement concrete pavement, thickness as per design, over a prepared sub base with 43 grade cement or any other type PCC Grade M-30, Coarse and fine aggregate conforming to IS:383, maximum size od coarse aggregate not exceeding 25mm, mixed in a concrete mixer of not less then 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (Steel channel, laying and fixing of wedges. steel plates including levelling the formwork and laying and fixing of 125 micron thick polythene film, as per drawing), spreading the concrete with shovels, rakes, compacted using needle, and
77.1
-
-
... More
Reinstatement of katchi Patri and disposal of dismantled materials up to a lead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specification Clause 202
2609.4
-
-
... More
Interlocking concrete block pavement-80mm thick (M-35)
222
-
-
... More
Interlocking concrete block pavement-80mm thick (M-35)
222
-
-
... More
Automation Works at Stage-I (I/W)
-
-
-
... More
GSM BASED REMOTE TERMINAL UNITS WITH Analog and Digital, I/O, Parameter and features as specified to store and transmit data on GSM based to LMS and also compatible to satellite communication for Four Pump's (RTUs shalls be integrated with the starter Panels) & power backup of 1 No. UPS rating as per site requirement.
2
-
-
... More
GSM based wireless communication hardware for RTUs capable to transfer data from remote site to MCS/LMS with all accessories.
2
-
-
... More
Energy meters suitable for automation
4
-
-
... More
CSD/F Valve and/or acutuators of 150/200 mm dia valve of class 300 ASA.
4
-
-
... More
Actuator Panels & Pressure transmitter
4
-
-
... More
Hard wired timer circuit for actuators
4
-
-
... More
Level transmitter
2
-
-
... More
Isolation Transformer (440 V step down 220 V for protection of site automation)
4
-
-
... More
Over voltage & under voltage trip protection (350V-450V).
4
-
-
... More
Control cable between RTU and field instruments/ control panel
-
-
-
... More
Single cabling between RTU and field instruments, 2 Core x 1.5 PVC coated flexible screened cable
150
-
-
... More
4 Core x 2.5 sq mm Cu Power cable for valve actuator
100
-
-
... More
10C x 1.5 sq mm PVC coated flexible unscreened Cu cable
50
-
-
... More
Conduct Pipe 1" PVC
25
-
-
... More
Conduct Pipe 1.5" PVC
15
-
-
... More
Accessories like conduct pipe flexible pipes, PVC bend, AC & DC relays with base, lugs etc.
3
-
-
... More
Erection, Commissioning and Customization of IRTU and Software at site
2
-
-
... More
Erection, Commissioning and Customization of Actuator, Actuator Penel and Energy Meter at site.
2
-
-
... More
Dismantling of existing Headear, Valves & related accessories to accomated CSD/F, CID/F Valve &/OR actuators as per site requirement complete.
1
-
-
... More
Supply & fixing of common header 250 mm OR as per site requirement MS ERW Pipe.
1
-
-
... More
Automation Works at Stage-II
-
-
-
... More
GSM BASED REMOTE TERMINAL UNITS WITH Analog and Digital, I/O, Parameter and features as specified to store and transmit data on GSM based to LMS and also compatible to satellite communication for Four Pump's (RTUs shalls be integrated with the starter Panels) & power backup of 1 No. UPS rating as per site requirement.
2
-
-
... More
GSM based wireless communication hardware for RTUs capable to transfer data from remote site to MCS/LMS with all accessories.
2
-
-
... More
Energy meters suitable for automation
4
-
-
... More
CSD/F Valve and/or acutuators of 150/200 mm dia valve of class 300 ASA.
4
-
-
... More
Actuator Panels & Pressure transmitter
4
-
-
... More
Hard wired timer circuit for actuators
4
-
-
... More
Level transmitter
2
-
-
... More
Isolation Transformer (440 V step down 220 V for protection of site automation)
4
-
-
... More
Over voltage & under voltage trip protection (350V-450V)
4
-
-
... More
Control cable between RTU and field instruments/ control panel
-
-
-
... More
(i)- Single cabling between RTU and field instruments, 2 Core x 1.5 PVC coated flexible screened cable
150
-
-
... More
(ii)- 4 Core x 2.5 sq mm Cu Power cable for valve actuator
100
-
-
... More
(iii)- 10C x 1.5 sq mm PVC coated flexible unscreened Cu cable
50
-
-
... More
(iv)- Conduct Pipe 1" PVC
25
-
-
... More
(v)- Conduct Pipe 1.5" PVC
15
-
-
... More
Hard wired timer circuit for actuators
4
-
-
... More
Accessories like conduct pipe flexible pipes, PVC bend, AC & DC relays with base, lugs etc.
3
-
-
... More
Erection, Commissioning and Customization of IRTU and Software at site
2
-
-
... More
Erection, Commissioning and Customization of Actuator, Actuator Penel and Energy Meter at site.
2
-
-
... More
Dismantling of existing Headear, Valves & related accessories to accomated CSD/F, CID/F Valve &/OR actuators as per site requirement complete.
1
-
-
... More
Supply & fixing of common header 250 mm OR as per site requirement MS ERW Pipe.
1
-
-
... More
Automation Works at Stage-III
-
-
-
... More
GSM BASED REMOTE TERMINAL UNITS WITH Analog and Digital, I/O, Parameter and features as specified to store and transmit data on GSM based to LMS and also compatible to satellite communication for Four Pump's (RTUs shalls be integrated with the starter Panels) & power backup of 1 No. UPS rating as per site requirement.
2
-
-
... More
GSM based wireless communication hardware for RTUs capable to transfer data from remote site to MCS/LMS with all accessories.
2
-
-
... More
Energy meters suitable for automation
4
-
-
... More
CSD/F Valve and/or acutuators of 150/200 mm dia valve of class 300 ASA.
4
-
-
... More
Actuator Panels & Pressure transmitter
4
-
-
... More
Hard wired timer circuit for actuators
4
-
-
... More
Level transmitter
2
-
-
... More
Isolation Transformer (440 V step down 220 V for protection of site automation)
4
-
-
... More
Over voltage & under voltage trip protection (350V-450V)
4
-
-
... More
Control cable between RTU and field instruments/ control panel
-
-
-
... More
Single cabling between RTU and field instruments, 2 Core x 1.5 PVC coated flexible screened cable
150
-
-
... More
4 Core x 2.5 sq mm Cu Power cable for valve actuator
100
-
-
... More
10C x 1.5 sq mm PVC coated flexible unscreened Cu cable
50
-
-
... More
Conduct Pipe 1" PVC
25
-
-
... More
Conduct Pipe 1.5" PVC
15
-
-
... More
Accessories like conduct pipe flexible pipes, PVC bend, AC & DC relays with base, lugs etc.
3
-
-
... More
Erection, Commissioning and Customization of IRTU and Software at site
2
-
-
... More
Erection, Commissioning and Customization of Actuator, Header, CSD/F, CID/F Valve Actuator Penel and Energy Meter at site.
2
-
-
... More
Dismantling of existing Headear, Valves & related accessories to accomated CSD/F, CID/F Valve &/OR actuators as per site requirement complete.
1
-
-
... More
Supply & fixing of common header 250 mm OR as per site requirement MS ERW Pipe.
1
-
-
... More
Trial & Testing Run for 06 Months
1
-
-
... More
Unforseen items
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%