Military Engineer Services Tender
View complete overview of Uttarakhand MES Tender
Military Engineer Services - MES Tender
Civil And Construction
Eprocure
Opening Date30 Sep 2024
Closing Date23 Oct 2024
Tender Amount₹ 25,00,000
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_677333_1Bid Award Id
ViewTender No
GE/RKT/42 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Returning, filling, including spareading, levelling, watering and well ramming in layers n. exc. 25 Cm in hard/dense soil complete all as specified & directed.
5
-
-
... More
Removing surplus excavated soil to a distance n. exc 50mtr & depositing where directed at a level n. exc 1.5 mtr above the starting point complete all as specified and directed.
20
-
-
... More
M & L P.C.C. 1:4:8 type D2 as in foundations, filling and mass concrete work complete all as specified and directed.
10
-
-
... More
M & L P.C.C. 1:3:6 type C2 as in foundations, filling and mass concrete work complete all as specified and directed.
10
-
-
... More
Demolition of brickwork or boulders/stone masonery built in cement mortar complete all as specified and directed.
35
-
-
... More
M&L for brick work with sub class 'B' bricks using old size bricks straight or curved on plan exc 6 mtr mean radius, built in CM 1:6 all as specified and directed.
20
-
-
... More
M&L for precast cement concrete solid block masonry exc 10cm width and getting in cement 1:3:6 using (20mm aggregate) set in CM 1:6 complete all as specified and directed
15
-
-
... More
Construction of brick masonry Soakage wells excavation in Hard dense/disintagrated rock, fdn in PCC 1:3:6, walls of honey combed and solid brick work in CM ( 1:4) , RCC cover slab Type A-1 ( 1:1.5: 3 ( using 20 mm graded stone aggregate) duly reinforced with 8 mm TMT bar @ 120 mm C/C , filling with brick bats, complete of size 2.40 m x 3m depth complete all as specified and directed and shown on drawing No TD-309 sheet 1/4 to 4/4.
1750
-
-
... More
M & L P.C.C. 1:2:4 type B1 ( using 20mm graded aggrigate) as in benching and channels of manholes complete all as specified and directed.
-
-
-
... More
Demolition of reinforced cement conc. Of any description and in any position including reinforcement cut as required to facilitate demolition complete all as specified and directed.
-
-
-
... More
M & L providing precast cement concrete 1:2:4 type B1(20mm graded aggregate) as in cover slab for manholes, landing etc. setting in cement mortar 1:6 complete all as specified and directed.
750
-
-
... More
S & F M.S. TMT bars 10mmdia and over, cut to length,bent in shape required, including cranking bending hooks ends and binding with M.S.wire(annealed) not less then 0.9mm dia complete all specified & directed.
1700
-
-
... More
M & L 15mm thick rendering on fair faces of brick work or concrete surface in C:M 1:4 finished even and smoothwithout using extra cement complete all specified and directed.
1000
-
-
... More
Demolition and breaking up existing drain/Sewage pips 150 mm bore(SWG,A.C., or R.C.C.) set in cement mortar including cement concrete bedding haunching etc and removing from site to a distance not exc. 50 mtr complete all as specified and directed.
1000
-
-
... More
S&F 150mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors for sewage line complete all as specified and directed.
1000
-
-
... More
M & L for 150 mm bore salt glazed stone ware drain pipe grade-A laid in trenches and jointed in C:M 1:1 complete all as specified and directed.
4.5
-
-
... More
M & L for cement concrete (1:3:6) type C2 ( using 40 mm graded stone aggregate) as in bed to drain pips for 150mm bore pipes including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and
15
-
-
... More
Taking down AC rain water pipes (any size or pattern) including all fittings heads shoes bends swan necks etc complete.
10
-
-
... More
S&F 100 mm bore cast iron pipe (sand cast) as in soil, waste and vent pipe, in any length with or without ears, with cement joints fixed to walls, all as specified & directed.
600
-
-
... More
S&F 75 mm bore cast iron pipe (sand cast) as in soil waste and vent pipe, in any length with or without, with cement joints, fixed to walls all as specified & directed.
20
-
-
... More
S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches and in floors complete all as specified and directed.
150
-
-
... More
S&F of 75 mm bore PVC (SWR) pipe single socketed in as length with rubber ring as in vent pipe complete all as specified and directed
500
-
-
... More
S&F in repairs 100 mm dia cast iron bend (any radius) diminishing pieces or tapers including taking down existing & making good to match with existing surfaces
200
-
-
... More
S&F CI branch pieces, single (equal or unequal) ordinary or inverted (Spigot or socket tyes) or with parellel branches, 100 mm bore fitted with oval access door including taking down existing & making good to match with existing surfaces.
500
-
-
... More
S&F in repairs of 100 mm dia PVC (SWR) bend complete all as specified and directed
500
-
-
... More
S&F in repairs of 75 mm dia PVC (SWR) bend complete all as specified and directed
180
-
-
... More
Taking down cement plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water etc.&removing rubbish to a disance not exc 250m Complete all as specified and directed.
25
-
-
... More
M&L for 15 mm thick rendering on stone/brick masonry surface fair faces of brick work in CM 1:6 complete all as specified and directed.
15
-
-
... More
M&L for 15 mm thick rendering on stone/brick masonry surface other then fair faces of brick work in CM 1:6 complete all as specified and directed.
50
-
-
... More
M&L for applying two coats of cement base paint over a coat of primer on newly plastered surfaces of walls including preparation of surfaces complete.
30
-
-
... More
S&F 75mm dia PVC(SWR) floor trap plain with grating including jointing, with solvent cement complete all as specified and directed.
10
-
-
... More
S&F 110mm bore PVC (SWR) junction single, (Single 'T') equal or unequal complete all as specified and directed.
6
-
-
... More
S&F 75mm PVC (SWR) bend any radius complete all as specified and directed
10
-
-
... More
S&F 110mm PVC (SWR) bend any radius complete all as specified and directed
10
-
-
... More
S&F 75mm PVC (SWR) vent cowl complete all as specified and directed
50
-
-
... More
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
50
-
-
... More
M & L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in surface channel and drain complete all as specified and directed.
60
-
-
... More
Extra for forming fair finished drain or channel, 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred, stopped ends, complete all as specified and directed.
50
-
-
... More
M&L for sunken floor treatment as described as under (i) to (vii) :- Demolition of cement concrete of any description and in any position not otherwise specifically provided or in any type of filling in sunken portion & cleaned the sunken portion incl vertical wall surface complete as directed. M&L to fill the sunken floor with PCC ( 1:5:10) type E-2 using bk aggregate over the treated surface complete all as specified and directed. M& L 40mm thick (Min) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate with integral water proofing compound as per manufacturer instructions on bottom of sunken portion with proper slope towards spout. Vertical sides shall be plastered in CM (1:3) 15 mm thick mixed with water proofing compound as per manufacturer instructions. Plaster shall be extended over PCC coving when the same is green i.e. PCC & plaster be carried out at the same time complete all as specified and directed. After laying sewage/ plumbing pipes with fixtures in position 2 coats of OMIPLAS EP-101 epoxy compound shall be applied complete all as specified and directed. Spouts of 25mm dia GI pipe light grade projecting 450mm clear of face outer a wall with mosquito proof cap on inner face of pipe shall be provided to drain out seepage water ,including cutting holes and making good if needed as specified and directed. Test again of water tightness by pounding for 72 hours & rectify defects if any till total elimination of defects complete all as specified and directed.The sunken portion shall be tested for leakage / seepage / dampness by pounding with water for 72 hours. In case any defect is noticed the portion shall be grouted with cement slurry mixed with suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage / seepage / dampness is eliminated.
15
-
-
... More
S & F in repairs 10 Liters capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia including brackets and connections to pipe complete all as specified and as directed.
10
-
-
... More
S&F in repairs vitreous china squatting pan, 'Orissa' pattern, size 580mm x 440mm, white, with integral foot rests with 'P; or 'S' trap, including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. in reapairs including Provn of lime concrete bedding and making good to floor.
10
-
-
... More
S& F in repair Vitreous china premium/ 1st quality wash down water closet EWC(including seat cover) white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete in all respect all as specified.
10
-
-
... More
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
8
-
-
... More
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store.
15
-
-
... More
S&F GI water tubing of 15mm dia ,medium grade conforming to IS-1239(Part -1) including all fittings such as bends,tees,short pieces,connectors,elbows,reducers,union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed.
15
-
-
... More
Cleaning of PVC water storage tanks of capacity exc 250 ltr but n.exc 2000 ltrs mechanized dewatering of water including sludge from the tanks, cleaning internal & external tank surfaces with high pressure water spray, vaccum cleaning, anti bacterial spray, UV radiation, spray of bleaching powder including writing date of cleaning (with thick paint in capital bold letter) on each tank etc complete etc complete all as specified and as directed by Engineer-in-Charge.
Note : - Rate includes the following :-
(i) Opening & closing of tank covers properly before & after execution of cleaning work.
(ii) Removal & refixing of float valves of any size & description before & after execution of work.
(iii) Removal of sludge where directed by Engr - in- charge.
(iv) User completion certificate shall be produced by the contractor.
(v) If damage the tank during the cleaning, will re-fiting with new tank with contractor's risk.
(vi) If damage the float valve during the removal for re-fitting will re-fitting the same with contractor's risk.
130
-
-
... More
S&F in repairs 15mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram complete all as specified and directed.
12
-
-
... More
S&F in repairs 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram complete all as specified and directed.
-
-
-
... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.complete all as directed.
27
-
-
... More
M & L for screed bed or bedding layer 15mm thick in cement mortar(1:6) for laying floor finishes Complete all as specified and directed.
15
-
-
... More
M & L for non skid ceramic coloured /printed tiles 7 to 8 mm thick (square / Rectangular)area of each tiles exceeding 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles.
12
-
-
... More
M & L for glazed ceramic coloured / printed tiles 300mm x 450mm, 6 to 7mm thick, on vertical surfaces set and jointed in neat cement slurry and pointed in white/coloured cement to match the tiles, complete all as specified and as directed.
12
-
-
... More
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 for backing of Dado/ Skirting & Vertical surfaces
50
-
-
... More
M&L for Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement;. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
5
-
-