Military Engineer Services Tender
View complete overview of Uttarakhand MES Tender
Military Engineer Services - MES Tender
Civil And Construction
Eprocure
Opening Date15 Jun 2024
Closing Date12 Jul 2024
Tender Amount₹ 13,00,000
Costs
EMD
₹ 26,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_660043_1Bid Award Id
ViewTender No
8817/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specified complete all as directed.
20.75
-
-
... More
M& L for rendering in cement mortar (1:4), 15 mm thick finished even and smooth without using extra cement complete all as specified
150
-
-
... More
M&L for plastering 15mm thick in CM 1:6 on internal face of wall ,finished even and smooth without using extra cement complete all as specified and directed complete.
70
-
-
... More
M&L for brick work with modular size kiln well burnt bricks sub-class 'B', straight or curved on plan not exc 6m mean radius, built in CM 1:6, complete all as specified and directed.
16
-
-
... More
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
70
-
-
... More
M&L for preparation of new plastered wall surfaces and applying two coat of cement base paint complete all as specified and directed.
150
-
-
... More
M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection, surface finished even and smooth without using extra cement, laid in panels n exc 3 mtr long and joints shall be filled with the mixture of bitumen and sand in (1:3) by weight complete all as specified and directed.
70.5
-
-
... More
M&L for old Plastered Surfaces and applying two Coats of cement base paint on Walls complete all as specified and as directed.
500
-
-
... More
M&L for Preparation of Old decorated surface and applying one coat of white wash on Ceiling complete all as specified and as directed.
100
-
-
... More
M&L for two coat of synthetic enamel paint over a coat of red oxide primer over newely untreated steel surfaces of any description, over 10cm in width or girth, not otherwise described etc complete.
68.17
-
-
... More
M&L for Preparation of old surface of wall and applying two coats of distemper oil bound over chalk whiting priming coat complete all as specified and as directed.
100
-
-
... More
M & L for 100 mm thick cement concrete 1:4:8, type D2, with using 40 mm graded stone aggregate as in sub base to floors etc as specified and directed.
140
-
-
... More
M & L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate, 40mm thick as in floor, coping, finish the surfaces even and smooth with using extra cement complete as specified and directed.
34
-
-
... More
M & L for Chequered cement concrete tiles 20Cm x 20 Cm x 20mm thick over and including 15mm thick screed bed in CM 1:6, set, jointed with grey cement and pigments and pointed in neat cement slurry in floors complete as directed and specified.
140
-
-
... More
M & L for Running welding in repairs thickness of metal to be welded n.exc 6mm complete
2.5
-
-
... More
Taking down of steel gates/doors execeeding 2 Sqm each and re-fixing in the same opening after necessary repair complete all as specified and directed.
4
-
-
... More
S & F in repair Mild steel work as in Hooks and Pintle hinges for steel gates inclding necessary weling, cutting holes in wall,making good with PCC 1:2:4 type B1 and two coats of painting & wall finish to match with the existing complete all as specified and directed.
50
-
-
... More
Supply, fabriction and fixing in repair (partial repair work) mild steel framed work as in gates,grills,grating of drain, etc including MS plain black sheet, hand-made sliding bolts, etc complete with a coat of red oide primer all as specified and directed. (The MS section & thickness of plain sheet shall be matched with existing).
25
-
-
... More
S&F Mild Steel work with hollow MS tubular section square or rectangular section as rafter/purlin including necessary welding bolting complete with using ERW or induction butt welded tubes confirming to relevant I.S. Fe 410 -W (GdeE- 250) qualityA complete all as specified and directed
110
-
-
... More
M & L for Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tesile strength of 550 Mpa as in roof covering to wall, fixed with self tapping screws as specified
20
-
-
... More
Providing precast cement concrete louvres and jallies, 35mm thick type B0 1:2:4 ( 12.5mm graded aggregate) set in cement mortar (1:4)(mea-sured solid), including all mouldings but excluding frame
6.3
-
-
... More
S&F Reinforced concrete pipes 300 mm bore class NP2, laid and jointed complete with collars
3
-
-
... More
Dismantling fencing wire mesh, any type etc complete.
202.5
-
-
... More
Dismantling posts or struts (wood, steel or R.C.C.) any section,Posts embedded in including taking out embedded portion and making good disturbed ground Concrete, brick work, masonry, etc. etc complete.
64.4
-
-
... More
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface etc complete.
64.4
-
-
... More
M&L for Cement concrete(1:3:6) as in in foundations, filling and mass concrete using 40 mm graded stone aggregates etc complete.
7.82
-
-
... More
S&F for mild steel works as Angle iron post and struts in fencing post and iron flats for securing chain link fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 etc complete.
1020.68
-
-
... More
S&F for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete.
416.48
-
-
... More
All as per item No 31 above but 5mm dia and over upto and including 10mm dia bars as in stirrupsc
50
-
-
... More
S&F for Mild steel Screw bolt machine made with Hexagonal or square heads at one end and screwed the other or screw both ends; each screwed end to be fitted with washers and one hexagonal or square nut n. exc 5 cm long and dia of neck 10 mm all as specifed and directed
131.27
-
-
... More
Material supply only for Chain link fencing MS galvanised chin link etc complete.
289.58
-
-
... More
Fixing only chain link fencing including line wire any mesh size and any type of standard rail s staining bolt etc including provision of binding wire etc complete.
202.5
-
-
... More
M&L for Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strainging bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or stel pins, etc. as directed (each line wire to be measured)
5.4
-
-
... More
Dismantling RCC jallies, louver etc of any description fixed in any position
2
-
-
... More
M&L for brick work with modular size kiln well burnt bricks sub-class 'B', straight or curved on plan not exc 6m mean radius, built in CM 1:6, complete all as specified and directed.
1
-
-
... More
M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection, surface finished even and smooth without using extra cement, laid in panels n exc 3 mtr long and joints shall be filled with the mixture of bitumen and sand in (1:3) by weight complete all as specified and directed.
20.5
-
-
... More
M&L for preparation of new plastered wall surfaces and applying two coat of cement base paint complete all as specified and directed.
50
-
-
... More
M & L for Chequered cement concrete tiles 20 Cm x 20 Cm x 20 mm thick over and including 15mm thick screed bed in CM 1:6, set, jointed with grey cement and pigments and pointed in neat cement slurry in floors complete as directed and specified.
40
-
-
... More
M & L for Running welding in repairs thickness of metal to be welded n.exc 6mm complete
0.5
-
-
... More
Demolition of cement concrete in ground floors and pavings not exc. 15 Cm thickness (below/above ground level) including floor finishes all as specified and directed
6
-
-
... More
Dismantling floor hearth or wall tiling incl cement mortar bedding but not backing & rubbish off the premises complete all as specified and as directed by the Engineer -in - charge
10
-
-
... More
Demolition of stone/ boulder masonry,built in cement mortar incl all quions, arches, pillars etc. but excluding ashlar facings dressed stone work and precast concrete articles complete all as specified and directed.
0.2
-
-
... More
Demolition and breaking up 75/110/150/200/250 mm bore drain pipes, soil , waste and pipes etc (RCC/ SWG etc) of any description in trenches or floors, including connections and fittings complete all as specified and directed.
107
-
-
... More
Demolition and breaking up of 75/110 mm bore PVC pipes & fitted on walls and laid in trenches etc complete all as specified and directed.
60
-
-
... More
Raking out joints/ pointing to squared rubble stone masonry, coursed or uncoursed in walls built in cement mortar complete all as specified and directed.
2
-
-
... More
Dismantling structural steel work including doors, gates complete all as specified and directed.
0.2
-
-
... More
Site Clearance by cutting all bushes, shrubs, any type of vegetation etc complete all as specified and directed.and removing to distance exc 500 m but n exc 1.50 Km out side MD land complete all as specified and directed
10
-
-
... More
Excavation in trenches in sof/loose soil n exc 1.5 M wide & n exc 1.5 M in depth as in and getting out in soft/loose soil for shafts, wells, man holes and for sewage lines and foundation etc n exc 10 Sqm on plan all as specified.complete all as specified and as directed by the Engineer-in-charge
10
-
-
... More
Excavation in trenches n exc 1.5 M wide and exc 1.5 M deep but, n exc 3 M deep and getting out in soft/loose soil for shafts, wells, man holes and for sewage lines and foundation etc n exc 10 Sqm on plan complete all as specified and directed.
8
-
-
... More
Returning filling in of excavated any type soil including spreading leveling watering and well ramming in layers n exc 25 cm thick all as specified and directed by Engineer-in-Charge.
5
-
-
... More
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m
above the starting point complete all as specified and directed by the Engineer -in-charge.
12
-
-
... More
M&L for PCC (1:4:8) type D-2 using 40 mm graded aggregate as in foundation filling & mass concrete complete all as specified and directed.
4
-
-
... More
M&L for squared rubble walling, Jodhpur type brought upto courses well bonded bedded & solidly hearted built in CM (1:6) complete all as specified and directed.
0.2
-
-
... More
M&L for rendering 10mm thick on stone masonry surfaces or surface other than fair face of brick work in cement mortar of (1:4) and surfaces finishes even and fair complete all as specified and directed.
35
-
-
... More
M&L for Flush pointing to squared rubble masonry, coursed or uncoursed in CM 1:4 complete all as specified and directed
5
-
-
... More
M&L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping for manhole including slightly rounded or chamfered angles and including necessary form work finishing exposed surface complete all as specified and directed.
1
-
-
... More
M&L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate in drains and surface channels and finishing complete all as specified and directed by Engineer-in-Charge.
2.5
-
-
... More
Extra for forming fair finished drain or channel 30cm inner girth in cement concret, using extra cement, including forms, moulds, initred/stopped ends complete all as specified and directed.
30
-
-
... More
Add or deduct for item -61 above for each 25 mm girth or part there of over or under 30 cm complete all as specified and directed.
10
-
-
... More
M&L for rendering 15mm thick in CM 1:4 on stone masonry surfaces of wall ,including finish even and smooth surfaces using without extra cement. complete all as specified and directed
25
-
-
... More
M&L for rendering 15 mm thick on fair faces of brickwork or concrete surfaces in CM (1:4) , surface finished fair and even ,complete all specified and directed
15
-
-
... More
M&L 25mm thick PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in levelling course finished even and fair for laying floor finishes etc all specified and directed
20
-
-
... More
S&F Salt glazed stoneware pipe grade 'A' laid in trenches and jointed in CM 1:1 including testing all as specified & directed for the following bores :-
-
-
-
... More
(a) 100 mm
20
-
-
... More
(b) 150 mm
50
-
-
... More
(c) 200mm
30
-
-
... More
S& F Reinforced concrete pipes class NP-2 laid and jointed complete with collars as directed by engineer in charge for the following bores :-
-
-
-
... More
(a) 150mm
2
-
-
... More
(b) 200mm
5
-
-
... More
M&L concrete bed of PCC 1:4:8 type D2 using 40 mm graded stone aggregate for drain pipes bedding & hunching against the sides complete after pipes are laid, jointed and tested complete as specified
-
-
-
... More
(a) 100 mm
20
-
-
... More
(b) 150mm
100
-
-
... More
(c) 200mm
50
-
-
... More
Cutting/filling into existing manholes for connecting new sewage line 150 mm bore (internal dia of pipe ) incl making good to disturbed benching and haunching, plaster etc and forming new branch channel ( ½ round of ¾ section) if required in cement concrete 1:2:4 type B1 and smooth finished , reforming benching as required and as directed for internal dia for the following pipe. (Each Man hole shall be measured under this item )
10
-
-
... More
M&L TMT bars 6mm to 8 mm dia cut to length bent to shape required including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
50
-
-
... More
M&L for precast RCC 1:2:4 type B1 as in cover slab for manhole etc with plane faces complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
M&L for 50mm thick sand stone slab in as in manholes cover stone etc size not less than 0.60x 1.20 m ,set and pointed in CM 1:4 complete all as specified and directed.
10
-
-
... More
S&F PVC (SWR) pipes single socketed in any length with rubber rings joints laid in trenches or in floors of the following bore inculding cutting out wall /concrete and finishing of surface to match existing surface .
-
-
-
... More
(a) 75mm
10
-
-
... More
(b) 110mm
20
-
-
... More
S&F PVC (SWR) pipes single socketed in any length with rubber rings joints laid in fixed to walls including clamps of the following bore
-
-
-
... More
(a) 75mm
10
-
-
... More
(b) 110mm
20
-
-
... More
S&F PVC (SWR) pipe bend with accessable door of the following bore inculding cutting out wall /concrete and finishing of surface to match existing surface .
-
-
-
... More
(a) 75mm
5
-
-
... More
(b) 110mm
5
-
-
... More
S&F PVC (SWR) branch piece single (Y) equal or unequal bend with accessable doorof the following bore inculding cutting out wall /concrete and finishing of surface to match existing surface .
-
-
-
... More
(a) 75mm
5
-
-
... More
(b) 110mm
5
-
-
... More
S&F PVC (SWR) junction single (single `T') equal or unequal with accessable door of the following bore inculding cutting out wall /concrete and finishing of surface to match existing surface .
-
-
-
... More
(a) 75mm
5
-
-
... More
(b) 110mm
5
-
-
... More
S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed.
5
-
-
... More
S&F PVC(SWR) P/S trap 110 mm bore complete all as specified and directed.
10
-
-
... More
S&F in repairs PVC(SWR) floor trap 75mm outlet dia plain with grating including jointing with solvent cement inculding cutting out wall /concrete and finishing of surface to match existing surface complete all as specified and directed.
5
-
-
... More
S & F in repair of vitreous china squatting Pan “Orissa” Pattern, of size 580mm x 440mm white with integral foot rests (excluding flushing cistern and flush pipe) including provn of cement concrete bedding complete all as specified and directed.
5
-
-
... More
M & L for ceramic tiles of size 7 to 8mm thick (coloured) (Square/rectangular) area of each tile exc 0.11 but n exc 0.18 sqm, in floors, set & jointed in neat cement slurry and pointed in coloured cement over and including 15mm screed in CM 1:6 or with chemical cement to match complete all as specified and directed.
10
-
-
... More
Cleaning of chocked /blocked sewage lines of any description and in any position by taking out loose sediment sand ,grit, ash, sludge ,rags, fibres or vegetation from the following depth of sewage line or by rodding / by mechanical means and well flushing with adequate water including removal of sludge /debris to a distance exc 250 m but nex 500m and buried under ground complete all as as specified and as directed by Engineer-in-Charge
-
-
-
... More
(a) 100 mm
10
-
-
... More
(b) 150 mm
150
-
-
... More
(c) 200 mm
15
-
-
... More
Opening & cleaning of blockage from kitchen /bath traps or WC any pattern by rodding or manually upto Ist manhole complete all as directed and by Engineer-in-charge
10
-
-
... More
Cleaning of manholes of depth not exc 0.60 M deep mechanically or manually by taking off sludge/any deleterious material from the existing manhole of any size and removing the sludge to a distance beyond 2.00 KM from the habitation in sealed container and depositing the same all as specified and directed by Engineer-in-Charge
15
-
-
... More
All as per item No - 106 above but exc. 0.60 mtr and n. exc. 1.50 mtr deep.
50
-
-
... More
All as per itemm No- 106- above but first manhole depth exc 1.50 m but n exc 3.00 mtr
30
-
-
... More
Material & labour removing of tree grown in brick masonry, behind CI pipe, parapets, shafts etc including removing root from wall by chiseling carefully without damaging the structure and making good by brick work in CM 1: 6 including toothing, bonding and plastering in CM 1:4,by applying chemical treatment with GLYPHOSATE 41% complete as specified and directed by Engineer-in- charge.
10
-
-
... More
Taking out semi solid, liquid suspension sludge and foreign material from septic tanks/ soakage well of any description and any depth including pumping of water and removing and refixing of acessories and appliances required for safe disposal of sludge and foreign materials either by carrying the same in covered van or trolley at out side MOD land and burrying the same (semi solid/ liquid shall not be burried) in ground complete all as directed. (Note: The location at out side MOD land for disposal of foreign material obtained above shall be located by the contractor himself).
20
-
-
... More
Cleaning/clearing of under ground sewage lines any depth by removing any type of blockage from sewage line upto and including 200mm bore/ dia by hydraulic jet pressure water pipe, of sewage cleaning system with compressure and sewage sludge pumps complete mounted on truck/vechicle , from manholes to manholes including plugging of manholes temporarily as and when required and flushing with water after cleaning including intermediate manholes. Sludge/sludge water in form of semi solid/loose state will be disposed off either by carrying the same in covered van or trolley at out side MOD land and burrying the same (semi solid/ liquid shall not be burried) including taking off manhole covers and refixing the same after cleaning. ( Note :-The operation shall be executed/carried out with any kind of sewage cleaning system mounted on truck/vehical such as sewage cleaning Mechanical Pump / compressure/ water tank etc complete by using by Municipality and cost of same shall be deemed to be included in the rate quoted by the contractor.)
1
-
-
... More
Cleaning of WT by taking out sludge and sludge loading to the cart/ lorry & depositing out side MD land including bailing out water by manually or by any mechanical means all as specified and directed by Engr-in-Charge.
Note:- (i) Rate quoted includes bailing out water from WT and removing sludge depositing out side MD land.
2
-
-
... More
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.complete all as specified and directed.
1.8
-
-
... More
All as per item No 113 here-in-before but except bricks and -ditto- (Re-use the old serviceable bricks obtained from item No.2 above).
2
-
-
... More
M & L for chequered cement concrete tiles (glossy finish) 40 cm x 40 cm x 30 mm thick set ,jointed and pointed in neat cement slurry in floors with grey cement and pigment laid over 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specified and as directed.
8
-
-
Evaluation Notes How It Works ?