Military Engineer Services Tender
View complete overview of Uttarakhand MES Tender
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date10 Oct 2024
Closing Date7 Nov 2024
Tender Amount₹ 43,43,000
Costs
EMD
₹ 86,860Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679006_1Bid Award Id
ViewTender No
9968/DDN/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M & L rendering 15mm thick on cement mortar 1:6 finished on fair faces of brick work even and smooth without using extra cement.
200
-
-
M&L rendering 15 mm thick in cement morter 1:4 on fair faces of brickwork even and smooth without using extra cement.
150
-
-
M&L rendering 10 mm thick in cement mortar 1:3 in ceilings on fair faces of brickwork even and smooth without using extra cement.
50
-
-
M&L for preparation of newly plastered surface on ceilings and applying three coats of white wash on ceiling, off sets, pillar etc. all as directed and specified.
50
-
-
M&L for preparation of existing treatment on ceiling and applying three coats of white wash on ceiling, off sets, pillar etc all as directed by the Engineer-in-Charge.
500
-
-
M&L for preparation of newly plastered surface of walls including corners and applying two coats of distemper oil emulsion over applying of 1-1.5 mm thick wall care putty finish wall surface even & smooth all as specified and directed.
200
-
-
M&L for preparation of existing treatment of walls including corners and applying two coats of distemper oil emulsion over applying of 1-1.5 mm thick wall care putty finish wall surface even & smooth all as specified and directed.
800
-
-
M&L for preparation of newly plastered surface of walls including corners and applying two coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10
sqm over new surfaces over applying of 1-1.5 mm thick wall care putty finish wall surface even and smooth complete all as specified and directed.
150
-
-
M&L for preparation of existing treatment of walls including corners and applying two coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10
sqm over new surfaces over applying of 1-1.5 mm thick wall care putty finish wall surface even and smooth complete all as specified and directed.
800
-
-
Demolition of reinforced cement concrete, shelves, chajjas, slabs and similar work carefully and matching to adjoining disturbed surfaces all as directed.
1
-
-
M&L for reinforcement cement concrete Type B1 1:2:4 (20 mm graded stone aggregate) like in slabs, shelves, etc.
1
-
-
S&F Form work to shelves and the like including edges, surfaces finished rough complete all as specified and directed.
7
-
-
S&F Mild Steel TMT bar 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia as specified .
50
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises.
300
-
-
M &L glazed coloured ceramic tiles, of size 450mm x 300mm x 6 to 7mm thick as in vertical surfaces such as skirting/ dados etc, set over screed bed of 10 mm in CM 1:4 and jointed in neat cement slurry and pointed with white/ coloured cement to match the colour of tiles all as specified and directed.
180
-
-
M&L non skid/mat finish coloured joint free ceramic tiles 7 to 8 mm thick, area of each tile exc. 0.11 sqm but not excd. 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
120
-
-
Demolition of concrete in ground floors and pavings n.exc 15 cm (below or above ground level) incl removing to outside of md land complete all as specified & directed.
10
-
-
M&L for 25 mm thick cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) complete all as specified and directed.
900
-
-
M&L 20 to 22 mm thick for Machine cut kota stone slab flooring in one colour over 20 mm thick over CM 1:4 screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing and roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed.
900
-
-
M&L 10 to 15 mm thick for machine cut kota stone slab as in risers of steps, skirting, dado and pillar in one colour over 15 mm thick over CM 1:4 screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing and roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as spd and directed
100
-
-
Taking up or down steel tubing and connections including cleaning for refixing with all fittings for 15 mm bore GI tubing all as directed by the Engr-in-Charge.
80
-
-
Taking up or down steel tubing and connections including cleaning for refixing with all fittings for 20 mm bore GI tubing all as directed by the Engr-in-Charge.
50
-
-
S&F galvanised steel water tubing 15 mm bore medium grade galvanized with all fittings such as bends, tees, nipples, elbows, reducers, etc, fixed complete to walls and ceilings or laid in floors all as directed by the Engr-in-Charge.
80
-
-
S&F galvanised steel water tubing 20 mm bore medium grade galvanized with all fittings such as bends, tees, nipples, elbows, reducers, etc, fixed complete to walls and ceilings or laid in floors all as directed by the Engr-in-Charge.
50
-
-
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed by Engr-in-Charge.
25
-
-
M&L PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm dia outlet complete all as specified and directed.
20
-
-
S&F Wash basins of size 550x400mm, Vitreous China (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erectin including waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanksand fly-nuts, flange end bedded in red lead cement and other end fixed Each all as directed by the Engr-in-Charge.
8
-
-
S&F of waste pipe of 32mm dia PVC pipe for WHB & kitchen sink as specified and directed.
8
-
-
S&F for 15 mm PTMT bib tap of any colour high pressure screwed for iron pipe and fixed complete all as specified and directed.
20
-
-
S&F in repairs vitreous china water closet (squatting pan) orrisa pattern 580x440 mm size white with integral 'foot rests including provn of lime concrete bedding including connections to 'flushing cistern/pipe complete all as specified and directed including 100mm CI spun 'P' trap in one piece 60cm long.
12
-
-
S&F in repairs PVC low level flushing cistern 10 ltr capacity dual type including flush down pipe complete all as specified and directed.
12
-
-
S&F PVC connection 15mm size with PTMT nuts, of 450 mm length complete all as specified and directed.
10
-
-
S&F in repairs 600x450 mm size of spcified thickness looking mirror of 5.5mm thickness, with 40mm thick PVC frame of selected quality at alround,mounted on 6 mm thick BWPl ply, fitted to wooden plug with CP screws complete all as specified and directed.
10
-
-
S&F CP shower rose 15mm dia complete all as specified and directed.
8
-
-
S&F of pillar fancy type 15mm dia cast copper allow with capstan head chromium plated screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe and fixed.
8
-
-
S&F stop valves 15 mm bore fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed.
20
-
-
S&F in repair soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed by Engr-in-charge.
10
-
-
S&F in repair Bib tap, fancy type, brass chromium plated, with wall cap, with round headed knob, screwed for 15mm bore iron pipe complete all as specified.
30
-
-
Taking down chowkats or frames not exc. 1.5 Sq mtr each with shutters (without taking off shutters) from the frames complete all as specified and as directed.
20
-
-
Taking down chowkats or frames exc. 1.5 Sq mtr but n exc. 4 sqm each with shutters (without taking off shutters) from the frames complete all as specified and as directed.
4
-
-
Taking down shutter of any description exc 1.0 sq.m but n.exc 2.00 sqm each complete all as specified and directed.
15
-
-
Taking down shutter of any description exc. 2.00 sqm each complete all as specified and directed.
2
-
-
S&F prelaminated Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet and edges will be painted to match with prelam sheet, PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
60
-
-
S&F Factory made prelaminated solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded both side prelam PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both side prelam PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of both side prelam PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement as per specification & drawing complete all as specified and directed.
30
-
-
S&F for Pressed steel door frame of size 105 x 60 mm, double rebated for doors made out of 1.25mm thick mild steel sheet including necessary fixing lugs, hinges lock strike plate etc, complete all as specified and directed.
15
-
-
S&F for Pressed steel door frame of size 125 x 60 mm, double rebated for doors made out of 1.25mm thick mild steel sheet including necessary fixing lugs, hinges lock strike plate etc, complete all as specified and directed.
10
-
-
S&F 30m thick factory made glazed and skeleton shutter open rebated and prepared to receive glass gauge etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitered beads or clearing glass etc, size of members of shutters as specified in SSR part I section 8 clause 8.20 (a) of IInd class hard wood.
15
-
-
M&L 30mm thick 2nd class hard wood factory made plain framed panelled shutters (three panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces.The size of rail and stile as per IS:1003 (Part1),kiln seasoned and chemically pressure treated, all as specified and directed.
20
-
-
S & F of steel window with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed.
5
-
-
S & F of steel window with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
5
-
-
S&F for steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed.
6
-
-
S&F 200 mm mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as directed and specified.
30
-
-
S&F 150 mm mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as directed and specified.
15
-
-
S&F 150mm mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed.
20
-
-
S&F 125mm mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed.
4
-
-
S&F 100 mm size SS butt hinges medium weight cold rolled fixed/ welded to frame complete all as directed.
100
-
-
S&F 300 mm, mild steel ordinary rat rail rod pattern door springs including roller plate complete all as specified and directed.
20
-
-
S&F 250mm long Aluminium sliding door bolt with hasp & stapple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolt of extruded section.
20
-
-
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
2
-
-
S&F mild steel framed work as in grill, grating etc with end of bars shouldered and /or riveted or tonged into spikes, frame guard bars barrel iron doors, ladders, frame balusters, walk ways, railing. Grame work of water tanks and similar works confirming to Fe 290 Gde E-165 complete as specified and directed.
100
-
-
Ditto all as per above item here in before but for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc.
100
-
-
S&F in repair SS grade 204 drapery rod 20mm dia including decorative brackets, decorative finals at both ends & curtain rings 8 Nos (Minimum) complete all as specified and directed.
200
-
-
Dismantling of existing broken PVC 500 ltrs water tank complete all as specified and directed.
2
-
-
Dismantling of existing broken PVC 1000 ltrs water tank complete all as specified and directed.
3
-
-
S & F 1000 Ltrs capacity Rotational moulded, polythene water storage tanks ( cylindrical shape with vertical top closed) hoisted and fixed in position all as specified in SSR part I including Ball valves 20mm dia high pressure of PTMT with epoxy coated Aluminium rod & high density plastic bal screwed for iron pipe and fixed. (minimum weight 15mm-142gms/20mm-210gms/25mm-455gms/40mm-690gms) all as directed.
3
-
-
S & F 500 Ltrs capacity Rotational moulded, polythene water storage tanks ( cylindrical shape with vertical top closed) hoisted and fixed in position all as specified in SSR part I including Ball valves 20mm dia high pressure of PTMT with epoxy coated Aluminium rod & high density plastic bal screwed for iron pipe and fixed. (minimum weight 15mm-142gms/20mm-210gms/25mm-455gms/40mm-690gms) all as directed.
2
-
-
Taking down AC/Salt glazed ware pipes and fittings upto 110 mm complete all as specified and directed.
80
-
-
S&F in repair 75 mm bore UPVC (SWR) pipe pressure 4kgf/cm2 single socketed in any length with rubber ring, fixed on wall / laid in trenches or in floors complete all as specified and directed.
20
-
-
S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or fixed on walls complete all as specified and directed
60
-
-
S&F in repair 75 mm bore UPVC (SWR) bends any radius, complete all as specified and directed.
5
-
-
S&F in repair 110 mm bore UPVC (SWR) bends any radius, complete all as specified and directed.
5
-
-
S&F in repair 75 mm bore UPVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
5
-
-
S&F in repair 110 mm bore UPVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
5
-
-
M&L for 75 mm thick PCC 1:3:6 in bays type C2 as in plinth protection finished even smooth using extra cement & similar work complete all as specified and directed.
150
-
-
Removal of existing roof treatment of any description from roof surface including cleaning and washing the surface complete all as specified and directed.
940
-
-
M&L for providing roof treatment as per the following steps: -
i) Filling cracks of roof slab with approved chemical sealing compound and applying 15 mm thick rendering in CM 1:4 over neat cement slurry @ 3.00 Kg/Sqm over cleaned roof surface with use of approved water proofing compound. ii) Applying a coat of cold applied bituminous primer @ 0.30 Kg/Sqm followed APP modified five layer polymeric membrane 3mm thick, minimum weight 3.60 Kg/Sqm reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) and than by one coat of bituminous 85/25 @ 3.00 Kg/Sqm, laid as per the manufacturers instruction with side over lap of 75mm and end over lap of 100mm and finally finished with super silver sheild @ 0.10 Ltr/Square Meter all as per specified and directed. Note : The work of water proofing treatment shall be got executed thorugh manufacturer or authorised applicator only.
940
-
-
Taking out old damaged SGSW pipes from existing lines including necessary excavation in trenches and getting out in any type of soil, supply, laying and jointing of PVC pipe of 150mm dia including packing under and haunching against the sides of pipes in PCC (1:4:8) type D-2 and returning, filling in disposal of surplus soil to a distance n exc 50m complete all as specified and directed by the Engr-in-Charge..
50
-
-
M&L for heavy duty endura ceramic coloured tiles 9-10 mm thick dark shade (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floor etc. set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
100
-
-
S&F waste fitting brass chromium plated for 32mm bore with long screwed shanks and fly nuts including 32mm PVC waste pipe for WHB ,complete all as specified.
36
-
-
Taking down carefully copper/Aluminum point wiring (light, fan socket and power) complete including switches, ceiling rose lamp holder and regulator etc and removing from site and making good disturbed surfaces of walls/floors etc complete all as specified and directed by Eng-in-charge.
292
-
-
M&L for point wiring with 1.5 Sqmm. (nominal area) FRLS, single core PVC insulated 1100 Volts, grade multistranded copper conductor unsheathed in and including concealed PVC conduit medium duty 20 mm dia or higher and heavy grade conduit fittings and heavy duty accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.6mm thick for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, one green colour FRLS cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of following. Note: The wiring to be done as per IE rule and maintain colour code accordingly.
-
-
-
One light point point /bell buzzer point controlled by one-one way switch.
138
-
-
One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
48
-
-
One three pin 5 Amp socket on same board with other switches.
46
-
-
One three pin 5 Amp socket on independent board
46
-
-
One light point controlled by two way switch
2
-
-
All as per item No 84 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 2.5 Sq mm.
12
-
-
S&F switch piano flush, button type 5 Amp SP 250 V AC complete all as specified & directed.
278
-
-
S&F switch piano flush button type 15 Amps SP 250 V AC complete all as specified & directed.
12
-
-
S&F socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed.
92
-
-
S&F socket outlet two in one three pin 5 Amp and 15 Amp 2 module 120 W flush type complete al as specified.
12
-
-
S&F switch paino flush button type 5 Amp SP 2 way complete 250 V AC all as specified and directed.
4
-
-
S&F step type regulator socket type double module 5 step for ceiling fan 1200/1400 mm size 230 volts 6 Ampds 400 watts.
50
-
-
S&F ceiling rose, 3 terminal/PVC/polycarbonate, isolated body 250 V AC.
90
-
-
M&L lamp holder insulated body with back plate suitable for angle and batten fitting complete all as specified.
48
-
-
M&L sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 10 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC concealed conduit heavy duty accessories and fittings. PVC insulated unsheathed FRLS cable copper conductor multistranded of size 10 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed Make of PVC Wire: Havells/KEI/Finolex/L&T.
90
-
-
S&F sheet metal enclosures 240 volt with 200 Amp rated bus bar for double door 8 way DB,s IP-43 IK 09 metal door suitable for one MCB SPN as incoming and 06 MCB SP as out going complete all as specified and directed Make Legrand/Schneider/ABB..
8
-
-
S&F sheet metal enclosures Triple pole and neutral double door 415 Volt 4 way DBs IP-43 IK- 09 Vertical type suitable for 200 Ams rated bus bar & one MCCB 100 Amp as incoming and 12 MCB SP as outgoing complete all as specified and directed Make Legrand/Schneider/ABB.
1
-
-
S&F MCB double pole 240 Volt 10 KA 40 Amp 'B' series conforming to ISI marked complete all as specified & directed Make Legrand/Schneider/ABB...
8
-
-
S&F MCB single pole and 240 volt 10 KA 5-32 Amp 'B' series conforming to ISI marked all as specified and directed Make Legrand/Schneider/ABB...
58
-
-
S&F MCCB 415 Volt 16 KA 4 pole 125 Amp magnetic trip release & setting as incoming with fixing arrangement complete all as specified and directed. Make Legrand/Schneider/ABB..
1
-
-
S&F in replacement wall mounted tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed. Make: Philips cat part No TMC 501P1xT LED 22WP-3241(Tube Batten)/ Wipro Cat part No WI0922208 (Tube Batten)/ Havells Cat Part No LUMILINEPLUSBS20WLED865SPCSS (Tube Batten))
90
-
-
S&F mirror light with high out put diffuser 2 feet, 10 watt 220 V AC decorative type compact luminarious with decorative ends caps 9/10 Watt LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size .
Make Havells Cat No Edgelite or equilent in Philips/Wipro
2
-
-
S&F in replacement of ceiling fan 1200 mm sweep single phase 230 volts double ball bearing with down rod , canopy, blades etc BEE 5 star rated including connecting with twisted three cord flaxible copper conductor cable (23/.0076 ) from ceiling rose to connector of fan comlete all as specified and directed Make Havells/ Crompton/ Orient/ GEC.( Note: Old unserviceable ceiling fan will be deposited in E/M store yard. )
8
-
-
S & F high efficiency LED bulbs 1 X 12 watt that can be used as a ready replacement for existing GLS ad CFL direct fit in holder complete all as specified and directed.
48
-
-
Supply and Fixing Integral LED Bldg security Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 40/45 watt with efficiency 100 lumen/watt at system level, CCT5700K, with average life class 50,000 burning hours, complete all as specified and directed. Make:- Crompton model No. LSTP-45-CDL/Havells model No. ENDURAPEARLNEOSL 40WLED757PASYTOPC /Philips Cat Part No BRP409LED CW036MRFGIPSUGRand syska SSK-ST-40W.
4
-
-
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm, 900 RPM, single phase, 230V AC with louver all as specified and directed 30 mm sheet. including connection with twisted white three core flexible copper multistranded conductor cabl from ceiling rose to connector all a directed by Engineer-in-charge. Make:- Havells cat part No. Ventil Air DXWHT, CG cat No. BRISKAIR
4
-
-
S&F Geyser vertical mount type 25 Ltrs capacity five star rated , shockproof and rust proof metal body compact size including two nos PVC connection heavy duty and connecting with all fixing arrangement of nuts & bolts and fixing on wall complete all as specified & directed . MAKE: BAJAJ, RECOLD,/ HAVELLS . ( Note: old unserviceable Geyser will be deposited in E/ M store yard )
2
-
-
S & F Sheet metal enclosure SPN with a two pin and earth plug and socket complete with one 240 Volts 20 amp single pole MCB complete all as specrified & directed
2
-
-
M&L for Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for laying of underground cable, foundation of pole and getting out in soft/loose soil complete all as specified and directed.
16
-
-
M&L for Returning, filling in excavated soil in trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
12
-
-
M&L for Removing of excavated soil to a distance n. exc. 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
6
-
-
M&L for laying local dry clean sand filling for cushioning in trenches around under ground cable complete all as specified and directed.
5
-
-
M&L for laying well burnt brick, old size in trenches, as protection of under ground cable complete all as specified and directed.
640
-
-
Supply, laying, jointing and testing of underground XLPE insulated, armouredheavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm 4 Core laid in trenches/ducts/along poles/through pipe under road etc with new aluminium lugs of cable size all as specified and directed. Make -Havells/ICL/Gloster/Plaza/KALINGA/Finolex/Polycab
100
-
-
Supply and laying galvanised steel tubing 50mm bore light grade laid in trenches or fixed to poles/walls etc for cable protection complete all as specified and directed.
6
-
-
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground end vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5 M below normal ground level connected to galvanized steel earth wire 4 mm dia by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1, cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm c/c both ways, and with one handle for lifting made out of 10 mm dia MS round bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing (light grade) for protection of earth lead connection, including necessary excavation and earth work in any type of soil and necessary testing complete all as shown on electrical plate No 3 of SSR Part –I (2009) and as directed.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements