Military Engineer Services Tender
View complete overview of Uttarakhand MES Tender
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date17 Jan 2025
Closing Soon7 Feb 2025
Tender Amount₹ 35,00,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair And Maint Of Dg Set And Amf Panel Including Other Infrastructure And Repair /replacement/renewal Of Earthing At Mh Area, Rimc , Sig Coy And Various Other Locations Under Age E/m-ii Of Ge Dehradun.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_693719_1Tender No
8926/A/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
200 KVA DG Set
Make Cummins without AMF
1
-
-
... More
82.5 KVA DG Set
Make Kirloskar with AMF
1
-
-
... More
62.5 KVA DG Set
Make Kirloskar without AMF
2
-
-
... More
40 KVA DG Set
Make Kirloskar without AMF
2
-
-
... More
70 HP IC engine pump
Make Kirloskar
1
-
-
... More
Material and labour for Taking down radiator from DG Set of any type /make of following capacity from base mounting , cleaning /descaling by using of air compressor and cleaning with suitable stain removal detergent along with chemical etc and rectifing water leakage by means of welding / brazing, after cleaning , descaling and rectifing of leakage etc. including renewal of all connecting parts i.e radiator hose pipe with clamps , bolts, nuts washers , rubber bush packing materal etc and re-assembling the radiatorand fixing with DG set properly in original position, checking the alignment, making proper hose connecting, testing for smooth operation complete all as specified and directed .
-
-
-
... More
(b) 500 KVA DG Set
1
-
-
... More
(c) 250 KVA DG set
3
-
-
... More
(d) 200 KVA DG Set
1
-
-
... More
(f) 82.5 KVA DG Set
1
-
-
... More
(e) 62.5 KVA DG Set
2
-
-
... More
(f) 40 KVA DG Set
2
-
-
... More
(g) 70 HP IC engine pump
1
-
-
... More
Material and labour for taking down of existing fuel from fuel tank of following capacity DG set by any means, removing of sludge and sediments deposited inside the fuel tank by repeatedly washing by using of chemical & detergent with air compressor including rectifing of leakage if found and refixing the same in position duly painted by spray painting as per direction of engineer in charge by testing complete all as specified and directed .
-
-
-
... More
500 KVA DG Set
1
-
-
... More
250 KVA DG set
3
-
-
... More
200 KVA DG Set
1
-
-
... More
82.5 KVA DG Set
1
-
-
... More
62.5 KVA DG Set
2
-
-
... More
40 KVA DG Set
2
-
-
... More
70 HP IC engine pump
1
-
-
... More
Supply and re-filling of new engine oil ( 20 W- 40 grade), sealed drum of (Packing of 210 litrs) complete all as specified and directed . Make SERVO OF IOC/HINDUSTAN PETROLEUM/ CASTROL) as approved by GE. . Make: Castrol Super /Hindustan petrollium.
420
-
-
... More
Supply only raditor coolant concentrate complete all as specified and directed . Make:- K- COOL SUPER PLUS/ CASTROL
420
-
-
... More
Supply & Filling of distilled water alongwith coolant as per ratio recommended by OEM including draining of radiator and removing sludge etc complete all as specified and directed .
420
-
-
... More
Material and labour for taking out of injector of DG Set of any type/make of following capacity, disconnection and opening of fuel injector assembly , carrying complete overhauling / servicing fuel injector system , including renewal of injector kit , calibration of injector , checking of pressure complete for each injector and re-assembling the same in original positon by making proper fuel connnection and testing for smooth operation complete all as specified and directed .
-
-
-
... More
500 KVA DG Set
1
-
-
... More
250 KVA DG set
3
-
-
... More
200 KVA DG Set
1
-
-
... More
(e) 82.5 KVA DG Set
1
-
-
... More
(f) 62.5 KVA DG Set
2
-
-
... More
(g) 40 KVA DG Set
2
-
-
... More
(h) 70 HP IC engine pump
1
-
-
... More
Supply and fix in replacement of Battery 12volt 150AH/180 AH complete all as specified and directed . Make:- Exide /Amaron
8
-
-
... More
Supply and fix in replacement of Battery 12volt 65/95 AH complete all as specified and directed . .Make:- Exide /Amaron
8
-
-
... More
Material and labour for repair of unserviceable Battery charger of 12V/24Volt complete all as specified and directed .
5
-
-
... More
Supply and fixing in replacement of Oil Pressure Sensor suitable for 500 KVA to 750 KVA DG set connecting with panel circuit, starting and testing on load complete all as specified and directed .
1
-
-
... More
Supply and fixing in replacement of Coolant Tempetarure Sensor suitable for 82.5 KVA to 250 KVA DG set connecting with panel circuit, starting and testing on load complete all as specified and directed .
1
-
-
... More
Supply and fixing in replacement Panel Control for 500 KVA DG set with accessories under over relay(JV Relay) including all charges like calibration and service charges as directed by Engr -in -charge Make Cummins(Jakson)
1
-
-
... More
Dismantiling exiting unserviceable 200 LPD/ 500 LPD solar water heating system ETC and re-fixing in its original position after necessary repair/ replacement of unserviceable spares (Evacuated Tube Collector) all as specified and directed. Note : Replacement of spares shall be measured & paid separately under respective items of Sch 'A'.
7
-
-
... More
Material and labour for cleaning of solar water heating system dismantled against item No 01 to 02 above and Servicing of solar water heater system by Cleaning complete tubes internally, Anti-scaling Cleaning of all effected parts . Removing any type of chocking of Solar Collector or tube, repairing any type leakage from Gasket, Rubber Washer after Cold Water inlet and before hot water outlet of Solar Water Heater with cleaning agent complete all as specified and directed.
7
-
-
... More
Supply and fixing of CPVC pipe line including all type of connected fittings for solar water heating system complete and taking down the same complete all as specified and directed .
110
-
-
... More
Supply and fix in repair hot water ,GI pipe line 20 mm dia (heavy grade) duly insulated with glass wool 50mm and aluminum cladding complete all as specified and directed.
80
-
-
... More
Supply and fix in replacement heating element of capacity of 3 KW, thread type, suitable for solar water heating system complete all as specified and directed.Make:- Theta,Newton,Dashmesh
7
-
-
... More
Supply and fix in replacement thermostat, suitable for solar water heating system complete all as specified and directed.Make:- Dashmesh,Indofoss,Bajaj
7
-
-
... More
Supply and fix in replacement silicon washer of size suitable for solar water heating system complete all as specified and directed.
5
-
-
... More
Supply and fix in replacement solar water heating system evacuated tube any size complete all as specified and directed.
36
-
-
... More
Supply and fixing in replacement aganist repairs of solenoid/ shut off valve of capacity 82.5 to 250 DG Sets of existing make along with screen Filter including wiring connecting to panel circuit, starting and testing on load complete all as specified and directed.
Make: As Per OEM Recommendation
1
-
-
... More
Supply and fix in replacement of selector switch suitable for 415volts complete all as specified and directed .
2
-
-
... More
Supply and fix in replacament of LED type phase indicator to be fitted on panel ( R,Y , B as per site requirement)
2
-
-
... More
Supply & fixing in replacment of digital type Voltmeter 0-500 volts with selector switch, 3 phase, complete all as specified and directed .
1
-
-
... More
Supply & fixing in replacment repairs of digital type Ammeter 0-200 Amps with 3 Nos CT coils and selector switch, 3 pohase complete all as specified and directed .
1
-
-
... More
Supply & fixing in replacment of digital type frequency meter of capacity 0 to 999.90 Hz,panel mounting complete all as specified and directed .
1
-
-
... More
Supply and fixing in replacement of the following accessories for 750KVA DG Set including cleaning and serviceing complete all as specified and directed .
-
-
-
... More
(a) Element Lub Oil Filter
4
-
-
... More
(b) Kit Fuel Filter and Ring
2
-
-
... More
(c) Kit Super Byp Filter Elem
2
-
-
... More
(d) Element air cleaner
2
-
-
... More
(e) Inhibitor corrosion 205 Liters
1
-
-
... More
(f) Battery Pulse Lite 12 V 160 AH
2
-
-
... More
(g) Valvoline Premium Blue 7800 Plus 1/210 Ltr
1
-
-
... More
(h) Hinge Canopy RHS
3
-
-
... More
(j) Radiwash 3 Liters
5
-
-
... More
(k) Foil Sealed Test Strips CC2602B
1
-
-
... More
Taking out Radiator form the 750 KVA DG set, dismantling all the parts cleaning and serviceing complete including replacement of petty spare parts , reclosing and refixing to its original position complete all as specified and directed .
1
-
-
... More
Supply and fixing AMF Panel Display (SGC 120) with all accessories required to suitable function for 62.5 KVA DG Set at MDC complete all as specified and directed .
1
-
-
... More
Taking out alternator dynamo form the 500 KVA DG set, dismantling all the parts cleaning and serviceing complete including replacement of petty spare parts , reclosing and refixing to its original position complete all as specified and directed .
1
-
-
... More
Taking out FIP from engine assembly shifting of FIP to work shop overhauling of FIP complete after repalcment of unserviceable parts callibration of FIP returning from workshop refixing to engine assembly including replacement of nozzles and cleaning of nozzle pipes complete all as specified and directed for upto 750 KVA capacity by DG set.
Note : (i) The cost of cleaning materials like kerosine oil cotton waste etc and lubricating item like mobile oil grease etc and patty spare parts required for this job are deemed inclusive in the rates. (ii) Nozzles and 'O' rings are to be measued and paid separatly.
1
-
-
... More
Material and labour for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, burried dirctly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead by means of bolts, nuts, check nuts and washer of galvanised iron strip 32 x 6mm as earth lead as shown in electrical plate No. 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal od surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm bore GI tubing medium grade for watering pipe, 40mm bore medium grade GI pipe for protection of GI earth strip and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) tyep A1 duly reinforced with 8mm dia TMT bar @ 100 mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick etc complete all as specified and directed including taking down old unserviceable one complete all as specified and directed. Note :- (i) Earth strip and its protection pipe upto and including 7.50 metre only from the top of earth electrode are included under theirs item. (ii) Any joints in earth lead from electrode to test point shall not be allowed. (iii) If the desired earth resistance is not found within permissible limit shall be re-done by contractor at no extra cost.
42
-
-
... More
Material and labour and installation Bus bar , factory fabricated bus bar chamber out door pedestal type made out of 2.0 mm thick CRCA sheet siz 750x500x400mm duly painted with powder coating, simens grey /RAL fitted with four Nos aluminium bus bar of capacity 630 Amps duly mounted epoxy insulator , cable connections of incoming and outgoing cables duly insulated PVC heat shrinkable sleeve 1.1 KV grade including one No MCCB 600 Amps , 04 pole , 50 KA , with adjustable thermal stetting Ics=100% Icu, including glands c/p lugs etc including 50x50x6mm angle iron frame 450mm height above ground level and 450mm below ground level , angle iron frame shall be embeded in PCC (1:2:4) type B 1 block of size 200x200x200mm complete all as specified and directed
5
-
-
... More
Supply and Laying XLPE insulated galvanised steel strip or wire armoured elctric power cable with stranded aluminium conductor 1100 V grade of size 300 sqmm 3.5 core after cutting to required length with necessary glands, nuts, bolts, and lugs completeincluding taking down existing unserveceable cable complete all as specified and directed
400
-
-
... More
Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unseviceable LT Cable for laying of cable and getting out. complete all as specified and directed .
89.1
-
-
... More
Sand cushioning and covering of UG cable using crushed metal sand in trenches for cable protection complete all as specified and directed . Note - Punned thickness shall be measured and paid.
26.7
-
-
... More
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in hard /loose soil complete all as specified and directed .
57.1
-
-
... More
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed .
37.7
-
-
... More
Material and labour for brick well burnt Class ‘B’ as cover to U/G cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over under ground cable for cable protection in trenches complete all as specified and directed .
2640
-
-
... More
Material and labour for GI tubing medium grade (ISI marked) with all fitting/acessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc all as specified and directed of size 40mm dia (make: prakash surya/jindal/TATA)
12
-
-
... More
Taking down old U/S MCCB from existing panel board and Supply and fix for new moulded case circuit breaker 4 pole 400 Amps 36 KA capacity with microprocessor release complete all as specified and directed .
9
-
-
... More
Taking down old U/S MCCB from existing panel board and Supply and fix for new moulded case circuit breaker 4 pole 250 Amps 36 KA capacity with microprocessor release complete all as specified and directed .
6
-
-
... More
Taking down old U/S MCCB from existing panel board and Supply and fix for new moulded case circuit breaker 4 pole 160 Amps 36 KA capacity with microprocessor release complete all as specified and directed .
7
-
-
... More
NOTE:- Amount of credit of Rs. 53128.00 for retrieved materials is mentioned in Schedule of Credit Page No 22 of tender documents in pdf form which will be deducted offline while acceptance of tender.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%