Military Engineer Services Tender

View complete overview of Uttarakhand MES Tender

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Feb 2024
Closing Date5 Mar 2024
Tender Amount₹ 23,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Tripping coil assembly 30/24 /110volts DC.

1

-

-

... More
Spring charge motor, single phase suitable for spring charge motorised mechanism

1

-

-

... More
Motor cut off limit switch.

1

-

-

... More
Disconnecting, dismantling / opening non functional VCB indoor type of any description and any make of rating 33 KV,1250/630 Amps capacity for servicing / overhauling, taking out and removing unserviceable/defective parts including cleaning & servicing ,greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling / servicing and its testing complete all as specified and directed. Notes :- (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch ‘A’ as supply only but fixing charges of the parts replaced/repaired is deemed to be included in these item.

1

-

-

... More
Supply only the following items / spare parts suitable for 33 KV VCB, 1250/630 Amps capacity of any make, dismantled/fixed under Sch ‘A’ item No.7 here in above complete all as specified and directed .

-

-

-

... More
Bushing (Female)

1

-

-

... More
Anti pumping device

1

-

-

... More
Closing coil assembly

1

-

-

... More
Tripping coil assembly

1

-

-

... More
Heating element with thermostat switch 150Watt compact type

1

-

-

... More
Motor cut off limit switch.

1

-

-

... More
Spring charge motor, single phase suitable for spring charge motorised mechanism

1

-

-

... More
Auxilary switch (6 NO + 6 NC ).

1

-

-

... More
HRC Fuse 32 Amp

1

-

-

... More
Disconnecting and taking out existing HT 11KV VCBs from housing and cleaning, rubbing and overhauling the mechanical parts incl Greasing oiling replacement of UNSV trip coil, breaker charging motor, gear panion, roller switch, Big gear etc and re-assembling the same after replacement as required and made the VCB serviceable including making all electrical connection and testing & calibration (IR Test, Continuity test, Tripping test of earth fault and Over current of panel ) alongwith control panel and control wiring, protection system and relays by primary & secondary injection system bank/battery chargers/DC system complete complete all as specified and directed by Engr-in-charge. Note :- (i): Any parts required for replacement to make the breaker serviceable will be measured and paid separately under appropriate item of Sch ‘A’ as supply only but fixing charges of the parts replaced/repaired is deemed to be included in these item (ii) All other accessories excluding sch item No: 19 to 28 to be supplied and fixed by the contractor at his own arrangement. (iii) calibration & testing will be carried out by machine which will be arranged by the contractor under his own arrangement.

2

-

-

... More
Supply only the following items / spare parts suitable for 11 KV VCB, 200/800 Amps capacity of any make, dismantled/fixed under Sch ‘A’ item No. 18 here in above complete all as specified and directed .

-

-

-

... More
Bushing (Female)

1

-

-

... More
flexible connectors

1

-

-

... More
Closing coil assembly 30/24 volts DC.

1

-

-

... More
Tripping coil assembly 30/24 volts DC.

1

-

-

... More
Heating element with thermostat switch 150 Watt compact type

1

-

-

... More
Motor cut off limit switch.

1

-

-

... More
Spring charge motor, single phase suitable for spring charge motorised mechanism

1

-

-

... More
Auxilary switch (6 NO + 6 NC ).

1

-

-

... More
11 KV bus insulator of suitable for 11 KV VCB/OCB Panel complete

1

-

-

... More
Disconnecting, dismantling,and taking out of unserviceable current Transformer from HT complete & Supplying installing commissioning and testing of new current transformer,outdoor epoxy type, ratio 180/0.578 conforming to IS 3156/1992/1992, 50 Hz for HT 11 KV having insulation level class1-P10, IL-28KV/75KV(P) , burden of 15VA and breaking capacity 18.4 KA for 1.0 second and necessary thimbles nut bolts etc complete all as specified and directed

1

-

-

... More
Disconnecting & taking down existing unserveceable PT any description any position, and supply, fixing, installation and testing of PT Indoor type suitable for 11 KV VCB 630/800 Amp Capacity complete all as specified and directed

1

-

-

... More
Supply, install, testing and commissioning in replacemen of unserviceable numerical over current & Earth falt relay type aux voltage 20 to 110 volts AC/DC, CT rating 1A or 5A , with inbuilt master trip & TCS feature. Relay should have minimum 4 digital Binary Inputs and 6 Digital output contacts suitable for AC/DC operation universel type including wiring of the relay with 1.5 Sqmm PVC insulated unsheted copper wire with numbering tags, thimble, insulation material, nut bolts etc complete all as specified and directed.Cat part No.MC61A of make L&T or equivalent model in specified makes ie siemens/Alstom/ABB/JVS as approved by GE

1

-

-

... More
Disconnecting & taking down existing unserveceable PT any description any position, and supply, fixing, installation and testing of PT outdoor type oil cooled,33KV/ /3-110V/ /3-110V/ /3,H.S.V 33KV INSUL.LEVEL -70KV/170KVp. RATED VOL FACTOR 1.2 CONT & 1.5 times for 30 sec,burden-100VA, class-1.0,Earthed type complete all as specified and directed.

1

-

-

... More
Dismantling of Old unserviceable batteries 12 Volt, from HT sub station and supply & fixing maintenance free batteries of 12 Volt, 180 AH capacity with electrolyte fully charged battery including interconnection, commissioning and testing complete all as specified & directed .

2

-

-

... More
Disconnecting and taking out old Unserviceable HT joint complete and Supply, jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for indoor termination, heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sq mm complete all as specified and ditected.

1

-

-

... More
Disconnecting and taking out old Unserviceable HT joint complete and Supply , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for outdoor termination, heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sq mm complete all as specified and ditected.

1

-

-

... More
Disconnecting and taking out old Unserviceable HT joint complete and Supply , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for indoor termination, heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sq mm complete all as specified and ditected.

2

-

-

... More
Disconnecting and taking out old Unserviceable HT joint complete and Supply , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for outdoor termination, heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sq mm complete all as specified and ditected.

2

-

-

... More
Supply , Install and testing in replacement of unserviceable HT 11kV vertical swing triple pole gang operated air break switch (GOD) consisting of twelve insulator (3 insulators in each phase and one each for DO fuse). Mounted over the MS channel frame, operating mechanism, operating handle GI medium grade 25 mm bore, 5 mtr long with locking arrangement system connected with operating handle and 7 leaver lock of Godrej, moving and fixed jaws, copper jumpher strip etc suitable for 11000 volt 200 Amp current rating all as specified and directed at site..

1

-

-

... More
Description all as per item No 38 above here-in before, but for GI wire complete, all as specified. Notes:-(i) The quoted rate is inclusive of the cost of Setting /adjusting of cradles in positions. Adjusting & tighting of stay assembly where ever required. (ii) The quoted rate is inclusive of the cost of old serviceable jumper of ACSR conductor shall be reused and fixed. (iv) The quoted rate is inclusive of the cost of Cutting/trimming of tree branches along with the exisitng HT overhead line 2 mtr clearence from all sides of ACSR conductor including removal from the site.

0.25

-

-

... More
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead 32X 6 mm GI strip, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate No . 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh incl necessary excavation and earth work in any type of soil, and PCC (1: 3 : 6) type C-1 (using 20 mm graded black trap/ granite/ Basalt stone aggregate) for earth pit with 40x40x6 mm mild steel angle iron frame for cover and 40 mm thick precast RCC cover in 1 : 2 : 4 type B1(using 20 mm graded black trap/granite/ basalt stone aggregate) with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle, complete all as specified & directed.

1

-

-

... More
Disconnecting and taking down carefully old unserviceable GI strip of any type and size and Material and labour for laying along the wall/roof GI strip of size 32mm x 6mm complete with all accessories such as porcelain insulators, saddles and fixing screw etc for conductor complete all as specified & directed.

10

-

-

... More
S&F in repelcement of UNSV battery bank battery 2 volt, 150 AH, suitable for minimum 10 hours rate of discharge battery bank for 11 KV complete all as specified and directed.

3

-

-

... More
Supply and fixing 33 KV Outdoor Motorised PCVCB of capacity 1500 MVA , 25 KA comprising of closing and tripping coil 24VDC with support structure 1250 Amps

1

-

-

... More
Disconnecting and removing the water and electric connections carefully from the existing submersible pump sets of any capacity, any size,any make and taking out the submersible pump set of alongwith column pipe 100 mm dia,electric cable and fittings of bore well or strip opening the pump set (approximately 450 feets depth of pump set from GL) and taking out the pump set alongwith pipes and fittings for flushing the bore well or strip opening the pump set for repairs, replacement of worn out spares, fixing of serviceable spares assembling the pump set completely, testing of pump set, lowering the pump set inside the bore well after repairs, including connecting back the water and electric connections, Commissioning of pump set for satisfactory operation on its full load complete all as specified and directed. NOTES : 1. Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost. 2. Number of column pipe may vary from 30 to 50, The existing pipes & flanged joints shall be checked for its serviceability & unserviceable joints alongwith flanges shall be removed from the column pipe by cutting the pipes & making new thread in pipes for fixing of new flange joint, the cost of same shall be deemed to be included in the quoted rate for above item. However cleaning of pipes if any required shall be measured & paid separately. 3. Expendable stores like cotton waste/cleaning materials lubricants , gland packing metal filling, machinaing and transportation to and fro from site to work shop are deemed to be included in rate quoted. 4.The spares required for repair the pump sets,motor,MS pipe,MS Nut& botls ,rubber gasketjoints and rewinding of motors shall be measured and paid for separately as supply only under appropriate items of Schedule ‘A’. 5. Labour elemetns is included in unit rates.

1

-

-

... More
Opening the pump and motor for inspection, repairs and reassembling the pump and motor as per the original assembly after repairs/ replaceing the wourn out unserviceable parts with new parts as ordered (the parts including cleaning replacing the minor items like, packing bolts, nuts and washers and MS clamps etc) making the pump and motor fully serviceable including machining etc and testing the both after refixing duly testing and commissioning all as specified and directed by the E-in-Charge for 35 to 52 HP capacity, 3 phase, 415 volts, 50 HZ, AC supply, pumps & motors of make KSB / SU / CALAMA. complete all as specified and directed. Note: - (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing rate for new items are deemed to include under these items. (ii) Burnt out windings of motor shall be replaced, measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include transportation to & fro of pumps/ motors to workshop as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at workshop. (iv) The rate quoted for the item shall include re-metaling of Pump shaft, polishing and grinding and making standard size to match with Gun Metal Bush/Neck-ring. (v) Lifting of pump and motor from bore well and lowering of pump and motor after repairs shall be measured and paid separately under appropriate item of Schedule `A' (vi) The quoted rate shall be deemed to include replacement of small/ minor parts i.e. washers, keys for coupling, cable packing ring etc.

1

-

-

... More
Supply only following items / spare parts suitable for AC submersible pump set of 35 to 50 HP capacity dismantled / fixed under Sch ‘A’ item No. 44 here in above complete all as specified and directed.

-

-

-

... More
Cast iron stage bowl

1

-

-

... More
Gun metal neck ring

1

-

-

... More
Anti magnetic stainless steel pump shaft with key

1

-

-

... More
Gun metal impeller

1

-

-

... More
Stainless steel sleeve (Inlet)

1

-

-

... More
Stainless steel sleeve (Outlet)

1

-

-

... More
Running bush out let of Gun metal

1

-

-

... More
Stage bowl cover

1

-

-

... More
Bolt stud with nut and washers

2

-

-

... More
Running bush inlet of Gun metal

1

-

-

... More
Strainer stainless steel

1

-

-

... More
Shaft nut with washer

1

-

-

... More
Supply only the following items / spare parts suitable for Motor of AC submersible pump of 35 to 52 HP capacity dismantled/fixed under Sch ‘A’ item No. 45 here in above complete all as specified and directed.

-

-

-

... More
Stainless steel sleeve DE and NDE.

1

-

-

... More
Connector for motor

1

-

-

... More
Steel bolt

4

-

-

... More
Key for thrust plate

1

-

-

... More
Bush bearing (Set of two)

1

-

-

... More
Thrust bearing (Set of two)

1

-

-

... More
Cable pressure washer

1

-

-

... More
T-bolts with nuts

4

-

-

... More
Bearing bush rubber

1

-

-

... More
Thrust Plate

1

-

-

... More
M&L for rewinding the motor with PVC insulated copper conductor of same guage weight and tuns to achieve its full efficiency inclduing tying the windings and connecting the coils and brining the connections as that of exisitng complete all as specified and directed for submersible motor of following capacity:-

-

-

-

... More
45/50/60 HP, Three phase, 415 Volts, 50 Hz, AC supply complete all as specified and directed.

2

-

-

... More
Supply, fixing, testing & commissioning in replacement of unserviceable Power Contactor ML-4 type, 3 pole, coil voltage 415 / 440 Volts, 50 Hz with 2 NO + 2 NC auxiliary contacts, having current rating (AC3) of 70 Amps at 415 volts complete, all as specified and directed by directed Cat part No :- SS 90910 of make L&T or equivalent model in specified make as approved by GE.

1

-

-

... More
Material and labour for repair to run lead joints including using new spun yarn for the following sizes of CI pipes/fittings etc complete, all as specified and directed. Notes : (i) Earth work in excavation, returning filling in and removal shall be measured and paid separately.

-

-

-

... More
150 mm bore

5

-

-

... More
100mm bore

5

-

-

... More
Disconnecting,removing the water ,electric connections and taking out carefully the old existing defective electric motor, up to 20 HP of booster pump / centrifugal pump of any description and in any position, dismantling and strip opening of the motor, removing the old existing burnt windings, cleaning the slots & rewinding of the electric motor 12.5 HP, operating on 415 V, 3 Phase, 50 Hz AC supply with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc for powering multistage booster pumps/ centrifugal pumps & testing at workshop and transportation to site & refixing on existing platform complete, all as specified and directed.

1

-

-

... More
Disconnecting, removing the water, electric connections and taking out carefully defective booster/centrifugal pump of capacity Up to 20 HP, DSM model of Make Kirloskar,, three phase, 415 V, AC supply and carrying out necessary repairs and replacement of bearing bush, gland plate, impeller, nuts and bolts etc, any trasportation to workshop if required, Repair to bearing housing with metling and turning and fixing the same in position and testing on full load complete, all as specified and directed by directed

1

-

-

... More
Supply only the following items/spare parts suitable for centrigugal pump of capacity up to 20 HP dismantled/fixed under Sch `A` item No 76 and 77 here in above complete, all as specified and directed.

-

-

-

... More
CI impeller as per existing size

1

-

-

... More
MS stud with nut for split body complete size as per sample

1

-

-

... More
Ball bearing for driving and non driving end.

1

-

-

... More
CI sleeve of DE / NDE

1

-

-

... More
CI/MS gland packing plate

1

-

-

... More
CI bush (stuffing box bush)

1

-

-

... More
Pump shaft EN8 complete including making key groove with check nut

1

-

-

... More
Set of key with nut & washer

1

-

-

... More
Replacement of packing sheet

1

-

-

... More
Supply and fixing in replacement of unserviceable water gauge of range 0-100 psi, 100mm dia in delivery line with in incluing socket welding in pipe line complete, all as specified and directed.

2

-

-

... More
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep in soft/loose soil including forming sides and bottom surface to required levels/slops/gradients etc. complete, all as specified and directed. Note:- The disturbed surface of roads/paths/plinths etc. shall be repaired and quoted rates deemed to include this aspect.

36

-

-

... More
Returning, filling in, including spreading leveling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete, all as specified and directed.

31

-

-

... More
Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directed at a level not exceeding 1.5 mtr above starting point complete, all as specified and directed.

5

-

-

... More
Taking up or down old existing GI tubing and connections, including connected fittings/ accessories and fixtures of any description/ grade and in any position in trenches/under floors/road / floor /duct on walls etc and including cleaning for reuse if serviceable or unserviceable to be removal to store complete, all as specified and directed. (Note:- (i) Earth work in excavation, returning filling in and removal & GI fitting shall be measured and paid separately under appropriate items of Schedule ‘A’ for the following bore of pipes:-

-

-

-

... More
15 mm bore

12

-

-

... More
20 mm bore

12

-

-

... More
25 mm bore

12

-

-

... More
50 mm bore

12

-

-

... More
80 mm bore

18

-

-

... More
100 mm bore

24

-

-

... More
Supply, laying, connecting & testing of galvanised iron water tubing 'medium grade' conforming to IS-1239 with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc as required complete fixed to walls and ceilings, laid in trenches/under floor/under road or floors complete (Note:-(i) Earth work in excavation, returning filling in and removal & GI fitting shall be measured and paid separately under appropriate items of Schedule ‘A’)complete, all as specified and directed for the following bore of pipes :-

-

-

-

... More
15 mm bore

12

-

-

... More
20 mm bore

12

-

-

... More
25 mm bore

12

-

-

... More
50 mm bore

18

-

-

... More
80 mm bore

18

-

-

... More
100 mm bore

24

-

-

... More
Supply, fixing and testing in replacement of unserviceable Gate valve/Globe valve and Supply, fixing, jointing and testing, of gun metal globe or gate valve with iron wheel head, both ends screwed for iron pipe, conforming to IS 778 complete, all as specified and directed for following bore of pipes :- (Make: Sant/Bir/ Leader/Upadhaya)

-

-

-

... More
20mm bore

1

-

-

... More
25mm bore

1

-

-

... More
40mm bore

1

-

-

... More
50mm bore

1

-

-

... More
Taking out or down defective sluice valve from main line and opening carefully old defective sluice valve of any description and in any position for and including servicing, over-hauling / greasing etc, and replacement of old unserviceable / worn out parts and reassembling the sluice valve after repair and refixing the same & testing after installation complete, all as specified and directed for following bores :- Note :- (i) The cost of Earth work, joints & jointing materials washers, gaskets and minor parts shall be deemed to be included in the quoted rates but Replacement of the defective parts i.e. cast iron gate & stainless steel spindle of Sluice valve shall be measured and paid for separately as supply only under appropriate items of Schedule ‘A’

-

-

-

... More
150 mm bore

1

-

-

... More
100 mm bore

1

-

-

... More
80 mm bore

1

-

-

... More
Supply only stainless steel spindle, heavy duty, threaded, with and including one gun metal check unit suitable for sluice valves of any description dismantled/fixed under Sch `A` item No 111 here in above complete, all as specified and directed. for following bores :-

-

-

-

... More
150 mm bore

1

-

-

... More
100 mm bore

1

-

-

... More
80 mm bore

1

-

-

... More
Supply, installation, fixing, jointing and testing in replacement of unserviceable cast iron sluice valve of class PN-1 both ends flanged with iron wheel head and stainless steel spindle, short body type, conforming to IS-14846 of 2000 including rubber gasket and nut blot with washer for flange joints complete, all as specified and directed for following bores :- Notes:- The cost of Earth work, joints & jointing materials of the sluice valve shall be deemed to be included in the quoted rates.

-

-

-

... More
150 mm bore

1

-

-

... More
100 mm bore

1

-

-

... More
80 mm bore

1

-

-

... More
Labour only for checking the serviceability of the pipe line of any description and fixed in any position & replacement of un-serviceable/damaged/ broken parts either in single or in combination, dismantling and re-assembling the pipe fittings, CI Peag lead/ lead wool joint and making the pipe lines serviceable, fixing the pipe fittings in position, connecting to water supply and its testing on installation complete, all as specified and directed, by Engr-in-charge by emplooying one plumber and one helper (Unshild) by receving complaint slip from MES service centre and returning the same after completion the job to MES authority complete, all as specified and directed here in after in notes. NOTES :- (i) Replacement of parts i.e nipple, union, elbow, bend, reducer & etc for 15/20/25/40/50mm GI pipe fittings and CI pipe peag lead/ lead wool of any cap joints if any required at site, shall be measured and paid for separately under appropriate item of Schedule `A' as ‘supply only. (ii) Necessary T&P i.e. ladder, tools etc required for checking and making the pipe fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of pipe fittings of any description on walls / ground etc i.e. in any position at site. (iii) Required parts ie. thread/ adhesive etc and other minor items excluding the required spares parts for repairing and making the water supply line in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item. (iv) Contractor’s quoted rates is deemed to include for inspection/checking the serviceability of the pipe line removing the damaged unserviceable / broken parts, fixing the new parts.

10

-

-

... More
Supply only the following parts for Water supply GI fittings complete, all as specified and directed.

-

-

-

... More
Union 15mm bore

2

-

-

... More
Union 20mm bore

2

-

-

... More
Union 25mm bore

2

-

-

... More
Union 40mm bore

2

-

-

... More
Union 50mm bore

2

-

-

... More
Union 80mm bore

1

-

-

... More
Elbow 15mm bore

2

-

-

... More
Elbow 20mm bore

2

-

-

... More
Elbow 25mm bore

2

-

-

... More
Elbow 40mm bore

2

-

-

... More
Elbow 50mm bore

2

-

-

... More
Nipple 15mm bore and of any length upto 150mm

2

-

-

... More
Nipple 20mm bore and of any length upto 150mm

2

-

-

... More
Nipple 25mm bore and of any length upto 150mm

2

-

-

... More
Nipple 40mm bore and of any length upto 150mm

2

-

-

... More
Nipple 50mm bore and of any length upto 150mm

2

-

-

... More
GI socket 15mm bore

2

-

-

... More
GI socket 20 mm bore

2

-

-

... More
GI socket 25 mm bore

2

-

-

... More
Reducer 15X 20 mm

2

-

-

... More
Reducer 15X 25 mm

2

-

-

... More
Reducer 20X 25 mm

2

-

-

... More
Reducer 25X 40 mm

2

-

-

... More
Reducer 40X 50 mm

2

-

-

... More
Tee 15mm bore

2

-

-

... More
Tee 20mm bore

2

-

-

... More
Tee 25mm bore

2

-

-

... More
Tee 40mm bore

2

-

-

... More
Tee 50mm bore

2

-

-

... More
Tee 15 x20mm bore

2

-

-

... More
Tee 20 x25mm bore

2

-

-

... More
Tee 15 x25mm bore

2

-

-

... More
Tee 25 x40mm bore

2

-

-

... More
Tee 40 x50mm bore

2

-

-

... More
M & L for Cutting of the existing 80/100 150 mm bore of GI/ CI pipe line for rectifying leakage and reducing to required length, in position, for insertion of collars or Tee & other fittings including dewatering etc complete all as specified and directed. Note :- CI fittings, jointing materials and earth work shall be measured and paid separately. How ever cost of dewatering is included in the quoted rates.

2

-

-

... More
M&L for tyton rubber gasket joints for 150 mm bore pipe, complete all as specified and directed

5

-

-

... More
Supply and fix Fully Automatic Star Delta starters in sheet steel enclosure type MN/ML (motor rating AC 3, 415 V 50 Hz, 3 Ph for Submersible Pump set up to 75 HP /55 KW , relay Mx Range 45 to 75 HP , MN 65 FASD complete all as specified and directed. Make L&T cat No SS94022

1

-

-

... More
Material and labour for Descaling of condenser unit by rubbing with nylon brush/ cleaning rod using hydrochloric acid pumped through electric driver descaling pump including dismantling and connecting all dismantled components in proper position after servicing/ overhauling/ greasing etc replacement of packing gasket 3mm thick, nuts, bolts with washer, testing of water line for leakage & repairing of pipe line to make it leak proof complete all as specified and directed for the following AC plants :- Notes : (i) The de-scaling & cleaning of condenser (Heat Exchanger) of cooling tower shall be done by circulating concentrated de-scaling solution mixed with water of make as approved to the entire satisfaction of GE/Engineer-in-Charge complete all as specified in Sch ‘A’. (ii)The hydrochloric acid shall be used as a de-scaling solution mixed with water in a suitable proportion as approved by the GE/Engineer-in-Charge so as avoid damage to existing pipe lines.

-

-

-

... More
11 TR capacity AC Plant Package Type

1

-

-

... More
15 TR capacity AC Plant Package type

1

-

-

... More
2X15 TR capacity Central AC plant

1

-

-

... More
2X27 TR capacity central AC Plant

1

-

-

... More
VRV 16 HP heat pump type AC unit

2

-

-

... More
Servicing/ overhauling/ greasing of condensor coil, cooling coil and evaporator coil etc replacement of packing gasket, nuts, bolts with washer, testing of water line for leakage & repairing of pipe line to make it leak proof of capacity 3X11TR package type AC Plant (installed at Technical Area. DEAL) complete all as specified and directed by Engr-in-Chagre.

3

-

-

... More
Dismantling the head from compressor fitted in system, and strip opening of compressor head completely for servicing /overhauling mechanically and electrically, and checking of various components with precision instruments to assess the requirements of repair/replacement, and making inventories for repairs required and re-fixing the serviceable parts in position after proper cleaning, oiling/greasing,etc ,and removing & replacement of defective / unserviceable parts with new parts, as required at site, and reassembling the compressors head ensuring perfectly leak proof after cleaning the oil sump, oil pump connecting rod, piston, liner etc and filling of compressor oil, before charging of refrigerant gas to required pressure and testing at site on full load to the entire satisfaction complete all as specified and directed for following :- ( included notes mentioned in here in after) Notes: - (i) The replacement of defective / nonfunctional parts, and Refrigerant gas and compressor oil for top up shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing/filling rate for new items are deemed to include under these items. (ii) The refregrent gas to be pumped down before dismantlling the compressure head for avoid the wastage of gas. (iii) The quoted rate shall be deemed to include replacement of small/ minor parts for prroper functioning of compressure .

4

-

-

... More
M&L for cutting and grinding the crank-shaft as required to make it equivalent to manufacturer’s standard size and smoothening/ fine finishing,polishing of shaft to match with half section big end bearings, cleaning oil ports for proper lubrication complete all as specified and directed. Note : (i) The cost of taking out and re-fixing of the shaft / rod in position after necessary repairs is deemed to be included under the rates quoted by the contractor for respective Schedule `A' item. (ii) The rates for above items are deemed to include transportation to & fro of crank-shaft to workshop for necessary repairs.

1

-

-

... More
Supply only following items / spare parts suitable for ACCEL make compressors of Tech area dismantled / fixed complete all as specified and directed .

-

-

-

... More
set of aluminuam washer set

2

-

-

... More
Oil pump assembly.

1

-

-

... More
Shaft seal assembly.

2

-

-

... More
Discharge valve assembly inside compressor (R-22)

1

-

-

... More
Gasket set complete for SMC 4-65.

1

-

-

... More
Set of neoperne ''O" ring set for SMC 4-65.

2

-

-

... More
Oil pressure regulator valve.

1

-

-

... More
Suction stop valve 'o' ring set"

2

-

-

... More
Discharge stop valve 'o' ring set

1

-

-

... More
Discharge valve assembly

1

-

-

... More
Suction valve assembly

1

-

-

... More
Safety valve assembly

1

-

-

... More
Piston ring set

6

-

-

... More
Taflon sheet discharge and suction valve

4

-

-

... More
MainBushing with detachable coller for repair .50/.75mm u.s.

2

-

-

... More
Connecting rod

2

-

-

... More
Bolt for Connecting rod

6

-

-

... More
Castle nut

6

-

-

... More
Split pin

6

-

-

... More
Guide pin

6

-

-

... More
Big end bearing (half section bearing) 0.050/.0.75 MM U.S.

4

-

-

... More
Crank shaft

1

-

-

... More
Piston with pin and rings

3

-

-

... More
Cylinder liner for R-22. with suction valve

3

-

-

... More
Single frame unloader- 65 (bracket).

2

-

-

... More
Busing for piston pin.

6

-

-

... More
Set of neoperne ''O" ring set for SMC 6-65.

2

-

-

... More
Oil pressure regulator valve.

2

-

-

... More
V BELT B-68

1

-

-

... More
V BELT B-105

1

-

-

... More
Carrying out leak detection in the system of AC plants including nitrogen pressure testing for 24 hours and repairing the leakage by gas welding / electric welding of refrigerant pipes, replacement of valve gland, gaskets etc. and then creating vacuum for 4 hours before charging refrigerant gas R-22/R-407 in the system and testing the complete plant for working pressure for 24 hours complete, all as specified and directed. Note : R-22/R-407 gas shall be measured and paid separately under Schedule ‘A’ Item.

-

-

-

... More
2x15 TR TR capacity AC Plant (installed at SATCOM building )

1

-

-

... More
2x27 TR capacity AC Plant (installed at PRC Building)

1

-

-

... More
3x11 TR capacity AC Plant (installed at EMI/MC BldgTechnical area deal

2

-

-

... More
11 TR capacity AC Plant Package Type (CERS Tech Bldg)

2

-

-

... More
15 TR capacity AC Plant Package type (CERS Tech Bldg)

2

-

-

... More
VRV 16 HP heat pump type AC unit (CERS Tech Bldg)

2

-

-

... More
Supply of refrigerant gas monochloro difluoro methane (CHCLF2) R- 22 conforming to IS-5160 of 1983 , duly filled in factory sealed cylinder standard capacity for filling under Sch ‘A’ item No 203 to 208 and here in above complete, all as specified and directed.

30

-

-

... More
Supply of lubricating oil anti freezing for refrigeration in factory sealed container of standard capacity for filling under Sch ‘A’ items No 203 to 208 complete,all as specified and directed. Make: Servo froze -68-10c of IOC.

20

-

-

... More
Supply only R-407 refrigrant gas with testingn under Sch ‘A’ item 203 to 208 here in above complete, all as specified and directed.

10

-

-

... More
Supply fixing and testing in replacement of UNSV condencer safety valve of size ½”, for pressure 300 PSI with and Including ½”, mild steel socket duly welded on condenser ensuring perfectly leak proof joint with pressure testing complete all as specified and directed.

1

-

-

... More
Supply fixing and testing in replacement of UNSV water pressure gauge 100 mm dia of range 0 to 100 PSI for central AC plant complete all as specified & directed.

5

-

-

... More
Supply fixing and testing in replacement of UNSV Gas pressure gauge 100 mm dia of range 0 to 300 PSI for central AC plant complete all as specified & directed.

3

-

-

... More
Supply fixing and testing in replacement of UNSV liqud line filtter driers of suitable size for Package type AC plant 11TR complete all as specified & directed.

2

-

-

... More
Supply fixing and testing in replacement of UNSV thermostatic expansion valve (R-22) suitable for 27 TR capacity of central AC plant complete, all as specified and directed.

1

-

-

... More
Supply fixing and testing in replacement of UNSV thermostatic expansion valve (R-22) suitable for 15 TR capacity of central AC plant complete, all as specified and directed.

1

-

-

... More
Supply fixing and testing in replacement of UNSV thermostatic expansion valve (R-22/R 407) suitable for 5.5/7.5 TR capacity of central AC plant complete, all as specified and directed.

1

-

-

... More
Supply fixing and testing in replacement of UNSV capacity control solenoid valve 3 way, voltage rating 230V complete, all as specified and directed

2

-

-

... More
Disconnecting and removing old existing non functional electric motor, of any description and in any position from existing platform for compressor/blowers/pumps/ cooling towers and dismantling and strip opening of the motor, for cleaning oiling/greasing and fixing of serviceable parts in position and removing the old existing burnt windings, cleaning the slots & rewinding of the electric motor with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc for powering compressor /blowers /pumps / cooling towers and transportation to site & refixing on existing platform ,connecting with exising connections & testing on full load complete all as specified and directed for following capacity :- .

-

-

-

... More
3.0 HP to 7.5 HP capacity, Three phase 50 Hz AC supply

1

-

-

... More
Disconnecting and removing old existing non functional electric pump, of any description and in any position from existing platform for pumps and dismantling and opening of the pump, for cleaning oiling/greasing and fixing of bearing, imppler serviceable parts in position pumps and transportation to site & refixing on existing platform ,connecting with exising connections & testing on full load complete all as specified and directed for following capacity :- .

-

-

-

... More
3 to 7.5 HP capacity, Three phase 50 Hz AC supply

1

-

-

... More
Disconnecting and removing old existing non functional electric motor, of any description and in any position from existing platform for compressor/blowers/pumps/ cooling towers and dismantling the motor, for cleaning oiling/greasing and fixing of serviceable parts including bush, bearing, impeller, seal and gasket etc with nut bolt in position of compressor /blowers /pumps / cooling towers and transportation to site & refixing on existing platform ,connecting with exising connections & testing on full load complete all as specified and directed for following capacity :- .

-

-

-

... More
5 / 7.5 HP capacity, Three phase 50 Hz AC supply

1

-

-

... More
Supply fixing and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 32 to 70 Amps. Complete all as specified and directed. Make L&T or equievelent model.

1

-

-

... More
Supply fixing and testing in replacement of UNSV bimetal overload relays directly operated & directly mounted on ML type Power contactor for relay range of 18 to 45 Amps complete all as specified and directed. Make L&T or equievelent model.

2

-

-

... More
Supply fixing and testing in replacement of UNSV insulated connectors 4 pole 100 amps rating including testing complete, all as specified and directed

2

-

-

... More
Supply fixing and testing in replacement of UNSV insulated connectors 4 pole 63 amps rating including testing complete, all as specified and directed

2

-

-

... More
Supply fixing and testing in replacement of UNSV Electronic timers 415 Volts, 50 Hz, AC supply, with delay period of 9-30-Seconds complete all as specified and directed f make L&T or equievelent model of specified make as approved by the GE

2

-

-

... More
Supply, fixing, connecting and testing in replacement of UNSV thermostate heating/cooling of any description complete,all as specified and directed.

3

-

-

... More
Supply, fixing, connecting and testing in replacement of UNSV strip heater fins type, 3.0 KW, 230 volts, single phase, AC supply in any position complete, all as specified and directed.

3

-

-

... More
Supply, fixing, connecting and testing in replacement of UNSV Globe valve bruss for control of liquid line complete, all as specified and directed.

1

-

-

... More
Supply, fixing, connecting and testing in replacement of UNSV condenser fan motor for package type AC plant complete, all as specified and directed.

1

-

-

... More
Supply, fixing, connecting and testing in replacment of UNSV PCB for 11 TR ac plant complete, all as specified and directed.

3

-

-

... More
Note:- The following items shall be excuted in ITM Mussoorie

-

-

-

... More
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection covers/ bricks & stacking serviceable bricks for reuse and disposal of unserviceable covers within 50 m all as directed. Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and brick protection. (ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations

165

-

-

... More
All as per Item No- 237 here in before but depth beyond first 1.5 m and not exceeding 3 m

1

-

-

... More
M&L for Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified & directed.

135

-

-

... More
M&L for Removal of surplus excavated soils not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.

30

-

-

... More
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified & directed.

30

-

-

... More
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with flat, size 250 mm x 150mm x 40mm complete all as specified & directed.

1000

-

-

... More
Supplying and laying un-reinforced precast concrete cable cover, class HVP,type 1 with peak, size 300mm x 180mm x 40mm

1250

-

-

... More
Fixing / laying only old precasat concrete cable cover of any description as obtained from dismantling of the cable complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
Disconnecting and taking out old existing unserviceable/ corroded GI tubing of any description and in any position complete all as specified & directed.

30

-

-

... More
Supplying, laying & jointing GI water tubing, 100 mm bore, medium grade as in sleeving etc laid in trenches / ducts etc. complete all as specified & directed. (MAKE : TATA/JINDAL/TT SWASTIK)

18

-

-

... More
Supplying, laying & jointing GI water tubing, 80 mm bore, medium grade as in sleeving etc laid in trenches / ducts etc. complete all as specified & directed. (MAKE : TATA/JINDAL/TT SWASTIK)

12

-

-

... More
Dismantling & taking out unserviceable steel & iron items from poles and Supply & fixing cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts & bolts , washers , welding bending cold or hot , drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer complete all as specified & directed.

0.5

-

-

... More
Disconnecting and taking out old existing unserviceable/ non- functional LT Cable and Supplying, laying, jointing and testing cable XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminum conductor for working voltage upto and including 1100 Volts, cross sectional area of under mentioned size of cables laid in trenches/fixed on pole/wall / passed through pipe complete all as specified & directed. Make:Havells/CCI/ICL/GLOSTER/Incab/Nicco/Polycab/Plaza) (NOTE: Earth work, sand cushioning, pipe, clamps for holding cables and brick protection shall be measured and paid separately )

-

-

-

... More
70 Sqmm 3½ core

100

-

-

... More
120 Sqmm 3½ core

100

-

-

... More
Dismantling & taking out of old existing unserviceable insulators of any description and in any position from LT poles all as specified & directed.

2

-

-

... More
Supply and fixing in replacement shackle type porcelain vitreous, white, brown or green insulator for working pressure 1100V of 115mm dia and 100mm high including galvanized mild steel strip 31 x 3mm, insulator bolts 14mm dia washer and nut complete all as specified for LT lines fixed on poles.

2

-

-

... More
Dismantling & taking down of existing worn out / unserviceable aluminium conductor, steel reinforced (ACSR) of any description /size & in any position from existing LT Poles/Lines all as specified & directed.

0.5

-

-

... More
Material & labour of aluminium conductor, steel reinforced (ACSR) of any size/description on LT poles/lines including stringing, tightening, binding to insulators with aluminium wire making and connecting jumpers, connections etc including connecting, commissioning and testing complete all as specified & directed.

0.5

-

-

... More
Supplying and fixing in replacement of MCCB, 400 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Ics = 100% of Icu 35/36 kA with adjustable thermal & magnetic setting, of Make : Legrand/Seimens/Schnieder/Havells

1

-

-

... More
Supplying and fixing in replacement of MCCB, 160 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 25 kA with fixed thermal & magnetic setting, of Make : Legrand/Seimens/Schnieder/Havells

1

-

-

... More
Disconnecting & taking down old existing unserviceable changeover switch of any description and in any position complete and Supplying, fixing, testing and commissioning of side operated OFF Load type changeover switch 4 pole, 415 volts, 200 Amps with and including sheet enclosure complete all as specified and directed. Cat part No: IHBFFE0320 of make Havells or equivalent model of specified make as approved by GE.

1

-

-

... More
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed. NOTE : RCC pit cover shall be pre-cast of RCC (1:2;4) type B-1 80 mm thick reinforced with XPM weighting not less than 4 Kgs/Sqm in lieu of CI cover.

1

-

-

... More
Material and labour in replacement of UNSV GI strip of size 32mm x 6mm for laying along the wall/roof on batten or burried in ground or drawn in conduit pipe or fixed to poles or any other situation as directed or as required GI strip of size 32mm x 6mm earth continuity conductor complete with all accessories such as porcelain insulators, saddles and fixing screw etc for conductor all as specified and directed.

12

-

-

... More
All as per item No.260 here in above but using 4 mm dia galvanised iron or steel wire complete all as specified and directed.

12

-

-

... More
Supply & fixing in replacement of Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.

15

-

-

... More
Supplying, Laying, testing and commissioning in replacement of UNSV XLPE insulated, PVC sheathed (heavy duty) armoured shielded cable 120 Sqmm 3 core with aluminium conductor for working voltage upto 11KV (Earthed) ,conforming to IS 7098 Part-II amended upto date complete, having cross sectional area under mentioned size of cables laid in trenches/fixed on pole/wall / passed through pipe including making necessary connection with VCB/OCB/ 4 pole/2 pole structure etc. complete all as specified and directed. Make:Havells/CCI/ICL/GLOSTER/Incab/Nicco/Polycab/Plaza) (NOTE: Earth work, sand cushioning, pipe, clamps for holding cables and PCC protection shall be measured and paid separately )

410

-

-

... More
Disconnecting and taking out old Unserviceable HT joint complete and Supply , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for indoor termination, heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sq mm complete all as specified & directed.

1

-

-

... More
Disconnecting and taking out old Unserviceable HT joint complete and Supply , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for outdoor termination, heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sq mm complete all as specified & directed.

1

-

-

... More
Disconnecting and taking out old Unserviceable HT joint complete and Supply , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for straight through, heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sq mm complete all as specified & directed.

1

-

-

... More
Supply and fixing in rteplacement of UNSV Steel tubular swaged poles complete with cast iron base plate, final, taper plug bolt, nuts & screws of type 410 SP-55 (11 M long) complete all as specified & directed. Note :- Earthwork, cement concrete in foundation, coping, cross arms ACSR conductors will be measured and paid separately under relevant items.

1

-

-

... More
Supply and fixing in rteplacement of UNSV Steel tubular swaged poles complete with cast iron base plate, final, taper plug bolt, nuts & screws of type 410 SP-35 (9 M long) complete all as specified & directed. Note :- Earthwork, cement concrete in foundation, coping, cross arms ACSR conductors will be measured and paid separately under relevant items.

1

-

-

... More
Supply , Install and testing in replacement of unserviceable insulators pin type porcelain, vitreous, white, brown or green insulators,for working pressure 11000 volts of size 150mm height and 150 mm dia including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut, etc for HT lines fixed on poles complete all as specified and directed.

2

-

-

... More
Supply , Install and testing in replacement of unserviceable disc type porcelain, vitreous, white, brown or green insulators,for working pressure 11000 volts of size 145mm height and 255 mm dia including two in series assembly for tension with tension clamps for conductors, etc for HT lines fixed on poles complete all as specified and directed.

2

-

-

... More
Supply , Install and testing in replacement of unserviceable HT 11kV vertical swing triple pole gang operated air break switch (GOD) consisting of twelve insulator (3 insulators in each phase and one each for DO fuse). Mounted over the MS channel frame, operating mechanism, operating handle GI medium grade 25 mm bore, 5 mtr long with locking arrangement system connected with operating handle and 7 leaver lock of Godrej, moving and fixed jaws, copper jumpher strip etc suitable for 11000 volt 200 Amp current rating all as specified and directed at site.

1

-

-

... More
Dismantling and taking down existing unserviceable lightning arrestor of any capacity and any description and Supply, fixing, commissioning & testing of distribution class lighting arrestor of rating 12 KV capacity and 10 KA NDC(Peak) confirming to to IEC-99.4 including brackets, clamps, bolts, nuts and washers complete all as specified and directed.

1

-

-

... More
Supplying,Straightening and Stringing in replacement of UNSV aluminum conductor steel reinforced (ACSR) conductor off size including jointing the conductor with new conductor on existing HT pole and binding to insulator with the new aluminium wire binding wire 2 mm dia making and connecting jumper connections etc including connecting commissioning and testing complete all as specified & directed.

0.1

-

-

... More
Supplying, Straightening and Stringing in replacement of UNSV Guard/ cradles hexagonal/ rectangular, fabricated in replacement of UNSV galvanized steel wire 3.15 or 4mm dia complete all as specified & directed.

0.1

-

-

... More
M&L in replecement of UNSV jumper with weasel conductor suitable for HT, 11000 volts grade required at site with suitable size of luge on both end including proper crimpinf etc.complete, all as specified and directed.

10

-

-

... More
M & L for PCC 1:2:4 type B2 with 40mm grade stone aggregate as in foundation for outstanding around pole near feeder pillar/LT panel foundation of stays, including form work, fair finishing to exposed surface complete all as specified & directed.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.