Military Engineer Services Tender
View complete overview of Uttarakhand MES Tender
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Sep 2024
Closing Date3 Oct 2024
Tender Amount₹ 40,35,000
Costs
EMD
₹ 80,700Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_670733_1Bid Award Id
ViewTender No
89042/24-25/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply, fixing and testing in replacement Lightening arrester non linear resistor type conforming to IS 3070 Part I complete line with all fittings transmision class, discharge class-2 nominal discharge current 10KA & high discharge 100 KVA assembly suitable for 11 KV incl clamps, nuts, bolts & washers & connecting to earth with 4mm dia GI wire all as specefied and directed.
12
-
-
... More
M&L for MS cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including dismantling of old cross arms complete all as specified and directed.
3
-
-
... More
Supply, installation, commissioning and testing of switch Air break, Gang operated with 12 insulator switch Tripple pole mechanically operated, mounted on insulator and steel frame, with mechanism worked from ground level, for current rating 200 Amp operating Voltage 11 KV out door type vertical mounted type complete with locking arrangement, assembly with fuse mount carrier and fuse element of required capacity and isolate suitable for 11 KV including necessary electric connection and 11 KV fuse (drop out type) of capacity 10 Amp complete with DO fuses assembly with one No. operating Rod of 25 mm dia bore grade GI pipe of suitable length worked out from ground level and handle complete with lock and two Nos keys incl flat iron clamp 50mm x 6mm MS channel of suitable size & length for fixing GOD incl nut, bolt, washers including taking down existing set complete all as specified and directed.
8
-
-
... More
Supply, laying, jointing and testing in replacement HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 Sqmm 3 core complete all as specified and directed.
300
-
-
... More
Supply, laying, jointing and testing in replacement HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 120 Sqmm 3 core complete all as specified and directed.
280
-
-
... More
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
8
-
-
... More
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
4
-
-
... More
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
2
-
-
... More
M&L stringing and stretching Aluminium conductor, steel reinforced (ACSR) on HT/LT over head line including binding on insulator with aluminium binding wire or aluminium trap including dismantling of old ACSR complete all as specified and directed of the following sizes :-
(a) (Weasel) 6/1x2.59mm aluminium and 1x2.59 steel (b) Ferret (6/1 x2.11 mm aluminium and 1 x2.11 mm steel)
2.5
-
-
... More
M&L in replacement stay assembly complete comprising of 7/3.15 galvanised stranded stay wire of required length fixed to pole with and including FI clamps 50 x 6 mm size bolt, nuts washers, GI steel stay rod 20 mm dia and 1800 mm long stay bow 400 x 14mm, GI steel plate 300 x 300 x 6mm, two nos thimble loop insulator of size 90x140mm clearance hole 16mm including two coats of aluminium paint over a one coat of red oxide primer on exposed mild steel work as shown in electrical plate No. 1 of SSR part - I 2009 including the following :- (i) Excavation in post holes 0.42 mtr x 0.42 Mtr on plan & 1.67 Mtr deep for pole foundation in any type of soil, returning filling & well ramming including disposal soil to distance not exc. 50 mtrs from starting point complete all as specified and directed. (ii) PCC 1:3:6, type C-2 using 40mm graded stone aggregated as in foundation complete all as specified and directed.
10
-
-
... More
Supply and laying in replacement 80 mm bore dia GI steel tubing light grade with all fittings laid in trenches/ under roads/ along pole/ wall for protection of Cable/ GI wire/ GI strip etc complete all as specified and directed.
40
-
-
... More
Supply and laying in replacement 100 mm bore dia GI steel tubing light grade with all fittings laid in trenches/ under roads/ along pole/ wall for protection of Cable/ GI wire/ GI strip etc complete all as specified and directed.
36
-
-
... More
M&L for earthing complete with galvanised steel, earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in in electrical plate No 5 on page 19-49 of MES schedule 1991 Part I connected to main switch board /main DBs/ earthing test point Including all necessary excavation and earth work in hard/ dense soil common salt and charcoal dust mixed and packed 150 mm thick all-round the GI earth plate, watering pipe 20 mm dia G I medium grade . GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150C/C both ways and pit/ chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 25mm dia light grade up to 7.5m from complete all as specified, indicated on electrical plate No 5 and as directed including testing on completion.
NOTE: ( i ) Earth lead beyond 7.5 m from electrode to earth terminal GI pipe light grade 25mm/40mmdia for protection against mechanical damage to lead shall be measured separately (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost.
8
-
-
... More
All as per Sr item No. 16 but GI earth strip 32x6mm by means of nut, bolts, check nuts, washers of GI steel 40mm dia light grade 1.5 mtr long watering pipe with one socket and plug on top and 40mm dia GI pipe light grade for protection of earth strip upto a length of 7.5 mtr including PCC chamber RCC cover with lifting handle, layer of charcoal & salt including necessary excavation & earth work all as shown in EP No 5 connected to earthing test point all as specified and directed.
12
-
-
... More
All as per Sr item No. 16 but using copper plate 600mm x 600mm x 3.15mm thick electrode and copper strip 20x3mm by means of nut, bolts, check nuts, washers of GI steel 40mm dia light grade 1.5 mtr long watering pipe with one socket and plug on top and 40mm dia GI pipe light grade for protection of earth strip upto a length of 7.5 mtr incl PCC chamber RCC cover with lifting handle, layer of charcoal & salt including necessary excavation & earth work all as shown in EP No 5 connected to earthing test point all as specified and directed.
6
-
-
... More
M&L for one coat of aluminium paint of approved quality including preparation of existing old painted surface of steel tubular pole HT complete including flat iron clamps, bracing, cross arms etc and numbering of poles with white synthetic enamel paint over a circular painted base complete all as specified and directed.
180
-
-
... More
Tightening/ restringing existing loose/broken conductor ACSR/copper any type or size including binding with suitable binding wire and jointing jumpers as required at site complete all as specified and directed.
5
-
-
... More
Tightening and restringing existing loose/broken continuous GI wire 4 mm dia on existing HT over head lines including stringing all as required at site complete all as specified and directed.
1.5
-
-
... More
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified
200.68
-
-
... More
Excavation in trenches, n exc 1.5 m wide and exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and exc 1.5 m in depth and getting out in hard/dense soil complete all as specified
1.32
-
-
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
112
-
-
... More
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
89.11
-
-
... More
M&L for dry clean sand filling in trenches below and around under ground cable cushioning complete all as specified and directed. Note :- Thickness of sand cushioning shall be measured after punning.
38
-
-
... More
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mm x 180mm x 40mm complete all as specified and directed.
2666.7
-
-
... More
M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of steel tubular pole incl form work complete all as specified and directed.
5.33
-
-
... More
M & L for PCC (1: 4:8 ) type D-2 using 40mm graded stone aggregate as in bottom of pit for bed concrete of steel tubular pole incl form work complete all as specified and directed.
0.32
-
-
... More
M & L for PCC ( 1:2:4) type B-1 using 20mm graded stone aggregate as in coping including all form work complete all as specified and directed.
0.6
-
-
... More
Trimming of trees/branches from HT/LT pole clearing 2 meter horizontal 7.2 meter vertical distance from both side of conductor including shifting of cut trees from site complete all as specified and directed.
Note: (i) Each span have a distance 40 Mtr approximately.
(ii) All cutting branches of trees shall be thrown away/burnt at approximate 200 to 500 mtr away as directed.
200
-
-
... More
M&L in replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed.
100
-
-
... More
S&F in replacement of HT jumper of existing two/four pole structure of transformer etc including using winding of ACSR conductor (Weasel) 11 KV, including PG clamp nut, bolts, thimbles and washers etc as required at site complete all as specified and directed.
25
-
-
... More
M&L for disconnecting of defective transformer (indoor/outdoor) type capacity 25 KVA to 500 KVA, 11/433 KV copper wound from power mains and dismantling the same from 2/4 pole structure/plateform mounted substation at site and opening for removing of the unserviceable parts i.e. bushing, bushing rod, stud, lugs, nut & bolts as required and re-assembling after carrying out required repair and installation on existing 2/4 pole structure/plateform with neccessary arrangements including connecting up electricallly, commissioning and testing complete all as specified and directed.
Note : U/S, worn out items required replacement shall be measured and paid separately under respective items of Sch.
5
-
-
... More
M&L for HT porcelain bushing complete with brass finned copper rod with nuts & bolts, gasket complete capacity transformer 25 KVA to 160 KVA complete all as specified and directed.
6
-
-
... More
M&L for HT porcelain bushing complete with brass finned copper rod with nuts & bolts, gasket complete capacity transformer 250 KVA to 500 KVA complete all as specified and directed.
8
-
-
... More
M&L for LT porcelain bushing complete with brass/tinned copper rod with nuts & bolts and gasket set of capacity of transformer 25 KVA to 160 KVA complete all as specified and directed.
6
-
-
... More
M&L for LT porcelain bushing complete with brass/tinned copper rod with nuts & bolts and gasket set of capacity of transformer 250 KVA to 500 KVA complete all as specified and directed.
8
-
-
... More
M&L for painting of transformer of capacity 25 KVA to 100 KVA apply two coats of synthetic enameled paint of grey colour by spray painting complete including preparation of old surfaces by removing dust, oil, grease etc complete all as specified and directed.
8
-
-
... More
M&L for painting of transformer of capacity above 100 KVA apply two coats of synthetic enameled paint of grey colour by spray painting complete including preparation of old surfaces by removing dust, oil, grease etc complete all as specified and directed.
18
-
-
... More
Checking the condition of Silica gel and packing the same to bring it to required blueish colour and re-filling the new Silica gel in to the breather complete all as specified and directed.
5
-
-
... More
Supply, fixing, connecting and testing in replacement of Volt meter 11 KV, suitable for 110/240 volt AC supply, flush type 96x96 mm digital type with LCD display and LED indicator complete all as specified and directed.
2
-
-
... More
Supply, fixing, connecting and testing in replacement of Amp meter 11 KV, 0-200 Amp with CT set suitable for 110/240 volt AC supply, flush type 96x96 mm digital type with LCD display and LED indicator complete all as specified and directed.
2
-
-
... More
S&F in replacement of indicator lamp 24 volt suitable for 110/240 volt AC supply, flush type 96x96 mm digital type with LCD display and LED indicatorcomplete all as specified and directed.
6
-
-
... More
Dehydration / filtration of transformer oil of existing transformer/ OCB installed at site with portable plant to improve the dielectric strength 45 to 60 KV during filling after initial filtration including testing of dielectric strength after dehydration at site complete all as specified and directed.
6000
-
-
... More
Supply & filling of transformer oil in transformer/ OCB for toping up the level of oil having dielectric strength 40-60 KV during filling after initial filtration conforming to IS-335 complete all as specified and directed.
500
-
-
... More
S&F breather suitable for transformer complete all as specified and directed.
14
-
-
... More
M&L for Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed.
1
-
-
... More
S&F HT cable/ route indicator cast iron of suitable size along HT cable trench including stringing and stretching, planting in ground with PCC complete all as specified and directed.
65
-
-
... More
M&L in replacement of galvanised steel wire 4 mm dia for guard wire of HT/ LT over head line including binding on insulator with aluminium binding wire or aluminium trap complete all as specified and directed.
0.5
-
-
... More
M&L for calibration (all connections and Mechanism) cleaning servicing overhauling testing complete of 11KV OCB/VCB(SF6) as mentioned below
a). Taking out incoming and outgoing HT 11 KV 3 core cables from the electric system and calibrating the CTs of each VCB/OCB with the help of primary injection kit and testing it for proper tripping system in presence of Engr-in-charge and reconnecting the incoming and outgoing HT cables complete in panels.
b). Taking out overcurrent relay 02 Nos and Earth fault relay 01 No and calibration of relays with the help of secondary injection kit, and proper setting of relays and refixing back in existing positions testing of proper tripping system in presence of Engr-in-charge
c). Inspecting, servicing and checking all connections of control winding, proper availability of supply AC/DC, incoming and outgoing connections and tightening them, cleaning the contacts and terminal with CTC solution and using the blower for dusting complete testing it making OCB/VCB set trouble free service in full satisfaction of Engr-in-charge and inclusive of one primer coat with red oxide one under coat , one finishing coat with aluminium paint complete all as specified and directed.
4
-
-
... More
S&F in repair electronic PF meter digital type for 11 KV HT panels/ OCBs/ VCBs with connecting accessories complete all as specified and directed.
3
-
-
... More
S&F in repair PT Fuse for 11KV HT panels/OCB/VCB(SF6) for incoming/outgoing with connecting accessories complete all as specified and directed.
3
-
-
... More
S&F rotary selection switch double circuit for 11KV HT panels/switchgears complete all as specified and directed.
4
-
-
... More
Removing of old U/S relays of HT VCB/SF6 including supply & fixing of relay system in existing HT VCB panel complete with self powered microprocessor based programmable over current and earth fault relay, with self check facility, with programmable characteristics and data storage feature. as per exixting sample including calibrating and inspection and testing complete assembly complete all as specified and directed.
1
-
-
... More
Opening up the top cover of transformer and taking out the transformer Oil in a separate container after disconnecting the HT/LT side electric connections from both the primary & secondary side of the transformer of any type/description (indoor/ outdoor type) installed on pole/floor, for carrying out necessary repair/rewinding to HT/LT side after shifting the transformer to contractors work shop including taking out complete core assembly, Mugger the defective winding portion/taking out ,cleaning the laminated core and rewinding with appropriate gauge/ winding wire/strip winding of existing, description for transformer of capacity 100 to 400 KVA/including assembling & testing on completion & installation the same at the site all as specified and directed by the Engineer-In-Charge,.
Note:- 1. Winding of coil shall be measured and paid separately under respective item.
2. Transportation charges are inclusive in the quoted rates.
3. The cost for the dehydration of transformer oil if required shall be measured and paid separately.
4. The cost of insulation material such as paper, cotton tape, latheriod sheet, cork sheet etc are inclusive in the coated rates.
1
-
-
... More
Opening up the top cover of transformer and taking out the transformer Oil in a separate container after disconnecting the HT/LT side electric connections from both the primary & secondary side of the transformer of any type/description (indoor/ outdoor type) installed on pole/floor, for carrying out necessary repair/rewinding to HT/LT side after shifting the transformer to contractors work shop including taking out complete core assembly, Mugger the defective winding portion/taking out ,cleaning the laminated core and rewinding with appropriate gauge/ winding wire/strip winding of existing, description for transformer of capacity 50 to 100 KVA/ including assembling & testing on completion & installation the same at the site all as specified and directed by the Engineer-In-Charge,.
Note:- 1. Winding of coil shall be measured and paid separately under respective item.
2. Transportation charges are inclusive in the quoted rates.
3. The cost for the dehydration of transformer oil if required shall be measured and paid separately.
4. The cost of insulation material such as paper, cotton tape, latheriod sheet, cork sheet etc are inclusive in the coated rates.
1
-
-
... More
Supply only copper winding wire of any size/description suitable for step down transformer of any capacity, including winding of coils (HT) as per the manufactures design & specification to obtain rated KVA complete all as specified and directed.
100
-
-
... More
Supply only copper winding wire of any size/description suitable for step down transformer of any capacity, including winding of coils (LT) as per the manufactures design & specification to obtain rated KVA complete all as specified and directed.
60
-
-
... More
M&L for temparature guage 0 to 125 degree C with transformer installed at site with all accessories complete all as specified and directed.
6
-
-
... More
S&F drain valve for transformers upto 250KVA complete all as specified and directed.
4
-
-
... More
S&F drain valve for transformers with capacity more than 250KVA and upto 500 KVA complete all as specified and directed.
4
-
-
... More
M&L for loose filling with aggregates of gauge 40 mm to 80 mm in soakage well etc to the required level complete all as specified and directed.
25
-
-
... More
Supply and fix in repair battery bank unit with 12 Volt dry rechargeable batteries 80 AH in 02 Nos with in-built charger of 150 AH operating on 230 Volt, 50 Hz AC power supply complete with indicator lamp voltmeter and ameter and PVC insulated unsheathed copper cable single core 10 Sqmm of appx length 10m duly connected with brass terminal lugs both ends and suitable length appx 20 m of cable flexible 2 core 2.5 Sqmm from chargeable power/light plug to unit with 5 Amp plug top complete all as specified and directed.
1
-
-
... More
S & F guard cradles, make to shape, hexagonal / rectangular or any other shape directed by Engineer-in-charge, fabricated out of 4 mm dia GI wire including 14 SWG binding wire, MS channel, clamps as required and complete all as specified and directed.
2
-
-
... More
M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping of pole / floor/plinth finished fair and even complete all as specified and directed.
2
-
-
... More
S&F HT insulation tapes ISI Marked for terminating high voltage cables for insulation sealing of connection of wire and cable for bus bar insulation, transformer terminal insulation etc complete all as specified and directed.
12
-
-
... More
S&F HT DO fuse of capacity 10 Amp complete all as specified and directed.
65
-
-
... More
S&F HT DO fuse of capacity 20 Amp complete all as specified and directed.
60
-
-
... More
S&F HT DO fuse of capacity 30 Amp complete all as specified and directed.
50
-
-
... More
S&F HT DO fuse of capacity 40 Amp complete all as specified and directed.
50
-
-
... More
S&F HT DO fuse of capacity 50 Amp complete all as specified and directed.
45
-
-
... More
S&F fire retardent rubber mat of 1 Mtr x 2 Mtr x 19 mm having insulation capacity of 33 KV complete all as specified and directed.
6
-
-
... More
Fixing only chain link fencing including line wire, any mesh type of standard rails straining bolts etc., including provision of binding wire complete all as specified and directed.
Note: Chain link mesh shall be supplied and measured under relevant item of schedule
120
-
-
... More
Supply only chain link mild steel galvanised fencing (with mesh size 50x50 mm and dia 3.8mm )complete all as specified and directed.
450
-
-
... More
S&F for posts and struts in fencing including cutting tops to shape as directed, notching to shape for securing wire mess etc, drilling holes, flat iron fillets incl all necessary drilling,riveting/bolting etc and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
900
-
-
... More
M&L for PCC (1:4:8) type D-2 (40mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed.
3.6
-
-
... More
M&L for mild steel round bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
185
-
-
... More
M&L for preparation of new steel and iron surfaces of any description and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
34
-
-
... More
S & F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screw both ends; each screwed end to be fitted with washers and one hexagonal or square nut, bolt 100 mm long & Diameter of neck in mm Exc 100mm n exc 150mm complete all as specified and directed.
34
-
-
... More
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around ,in layers not exc 25 cm , in any type complete all as specified and directed.
30
-
-
Evaluation Notes How It Works ?