Military Engineer Services Tender

View complete overview of Uttarakhand MES Tender

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date18 Jan 2025
Closing Date8 Feb 2025
Tender Amount₹ 31,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
30 TR capacity AC plant (installed at Chetak Buildling ).

1

-

-

... More
45 TR capacity AC Plant (installed at Large Optics Building IRDE)

2

-

-

... More
65 TR capacity AC Plant (installed at MMG / Optics Building IRDE)

3

-

-

... More
80 TR capacity AC plant (installed at Photonic Buildling & EOL/ TIS Building IRDE).

3

-

-

... More
Dismantling the head from compressor fitted in system, and strip opening of compressor head of twin cylinder for compressor completely for servicing /overhauling mechanically and electrically, and checking of various components with precision instruments to assess the requirements of repair/replacement, and making inventories for repairs required and re-fixing the serviceable parts in position after proper cleaning, oiling/greasing,etc ,and removing & replacement of defective / unserviceable parts with new parts, as required at site, and reassembling the compressors head ensuring perfectly leak proof after cleaning the oil sump, oil pump connecting rod, piston, liner etc and filling of compressor oil, before charging of refrigerant gas to required pressure and testing at site on full load to the entire satisfaction complete all as specified and directed for following :- ( included notes mentioned in her Notes: - (i) The replacement of defective / nonfunctional parts, and Refrigerant gas and compressor oil for top up shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing/filling rate for new items are deemed to include under these items. (ii) The refregrent gas to be pumped down before dismantlling the compressure head for avoid the wastage of gas. (iii) The quoted rate shall be deemed to include replacement of small/ minor parts for prroper functioning of compressure .

-

-

-

... More
11 TR capacity AC Plant Package Type (installed at Mechanical Lab Technical Area. IRDE)

1

-

-

... More
27.5 /27 TR capacity AC Plant (installed at Micro /C V RAMAN Building IRDE)

2

-

-

... More
30 TR capacity AC plant (installed at Chetak Buildling ).

1

-

-

... More
45 TR capacity AC Plant (installed at Large Optics Building IRDE)

2

-

-

... More
65 TR capacity AC Plant (installed at MMG / Optics Building IRDE)

3

-

-

... More
80 TR capacity AC plant (installed at Photonic Buildling & EOL/ TIS Building IRDE).

3

-

-

... More
M&L for cutting and grinding the crank-shaft (for 27.5 TR of Kirloskar make/SMC 8-65 model of ACCEL compressor) of 0.50/0.75 mm around as required to make it equivalent to manufacturer’s standard size and smoothening/ fine finishing,polishing of shaft to match with half section big end bearings, cleaning oil ports for proper lubrication complete all as specified and directed by Engr-in-Charge. Note : (i) The cost of taking out and re-fixing of the shaft / rod in position after necessary repairs is deemed to be included under the rates quoted by the contractor for respective Schedule `A' item. (ii) The rates for above items are deemed to include transportation to & fro of crank-shaft to workshop for necessary repairs.

2

-

-

... More
Supply only following items / spare parts suitable for Kirloskar make compressors of semi sealed 27.5 TR / 8-65 Accel Make dismantled / fixed under Sch ‘A’ item No.15 here in above complete all as specified and directed

-

-

-

... More
Cylinder liner

2

-

-

... More
Piston Bare

2

-

-

... More
Compression ring set

2

-

-

... More
Piston pin/ gudgen pin

2

-

-

... More
Circlip internal

3

-

-

... More
Connecting rod -05mm

1

-

-

... More
Suction valve 'o' ring

2

-

-

... More
Suction & Discharge valve spring

3

-

-

... More
Discharge valve assembly (R-22)

2

-

-

... More
Crank shaft AC COMPRESSOR 27.5 TR of Make KIRLOSKER/8-65 Accel

1

-

-

... More
Safety plate

1

-

-

... More
Shaft seal assembly

1

-

-

... More
Rewinding of semi sealed compressure 27.5 TR

1

-

-

... More
Filter wire gauge

1

-

-

... More
Suction filter with nut

1

-

-

... More
Oil pump with ring set for compressure 27.5 TR

1

-

-

... More
Set of gasket for compressure 27.5 TR

1

-

-

... More
Main bearing .05 mm.

1

-

-

... More
Oil filter

1

-

-

... More
loading coil

1

-

-

... More
pressure gauge - 30 to 300 PSI

2

-

-

... More
Carrying out leak detection in the system of AC plants including nitrogen pressure testing for 24 hours and repairing the leakage by gas welding / electric welding of refrigerant pipes, replacement of valve gland, gaskets etc. and then creating vacuum for 4 hours before charging refrigerant gas R-22 in the system and testing the complete plant for working pressure for 24 hours complete, all as specified and directed. Note : R-22 gas shall be measured and paid separately under Schedule ‘A’ Item.

-

-

-

... More
11 TR capacity AC Plant Package Type(installed at Mechanical Lab Technical Area. IRDE)

1

-

-

... More
27.5 /27 TR capacity AC Plant

2

-

-

... More
30 TR capacity AC plant

1

-

-

... More
45 TR capacity AC Plant

1

-

-

... More
65 TR capacity AC Plant

3

-

-

... More
80 TR capacity AC plant

3

-

-

... More
Supply, fixing, connecting and testing in replacement of UNSV strip heater fins type, 3.0 KW, 230 volts, single phase, AC supply in any position complete, all as specified and directed.

25

-

-

... More
Heater Element size and capacity as per existing Watre heater Generator 100/54 KW complete, all as specified and directed.

1

-

-

... More
Supply of lubricating oil anti freezing for refrigeration in factory sealed container of standard capacity for filling under Sch ‘A’ items No 3 complete,all as specified and directed. Make: Servo froze -68-10c of IOC.

15

-

-

... More
Supply fixing and testing in replacement of UNSV pre filter with GI sheet frame of size 610mm x 610mm x 50mm deep suitable for Air handling units of air conditioning plants including efficiency 90% , down to 10-20microns, Initial Pressure drop- 2.5 mm WG, filter media shall be Synthetic Non Woven with Both Side HDPE Mesh, and testing complete complete, all as specified and directed.

15

-

-

... More
Supply fixing and testing in replacement of UNSV condencer safety valve of size 3/4"& ½”, for pressure 300 PSI with and Including 3/4"& ½”, mild steel socket duly welded on condenser ensuring perfectly leak proof joint with pressure testing complete all as specified and directed.

2

-

-

... More
Supply fixing and testing in replacement of UNSV water pressure gauge 100 mm dia of range 0 to 100 PSI suitable for central AC plant complete all as specified & directed.

5

-

-

... More
Supply fixing and testing in replacement of UNSV Gas pressure gauge 100 mm dia of range 0 to 300 PSI suitable for central AC plant complete all as specified & directed.

5

-

-

... More
Supply fixing and testing in replacement of UNSV Water flow switch for condenser and chiller suitable as per existing AC Plant Make :Carrier (Screw Chiller Unit) complete, all as specified and directed

1

-

-

... More
Supply fixing and testing in replacement of UNSV Loading/ unloading coil suitable for as per existing AC Plant. Make :Carrier (Screw Chiller Unit) complete, all as specified and directed

1

-

-

... More
Supply fixing and testing in replacement of UNSV PVC Fills of FPR cooling tower size 600mmx300mmx 150 mm complete, all as specified and directed

150

-

-

... More
Disconnecting and removing old existing non functional electric motor, of any description and in any position from existing platform for compressor/blowers/pumps/ cooling towers and dismantling and strip opening of the motor, for cleaning oiling/greasing and fixing of serviceable parts in position and removing the old existing burnt windings, cleaning the slots & rewinding of the electric motor with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc for powering compressor /blowers /pumps / cooling towers and transportation to site & refixing on existing platform ,connecting with exising connections & testing on full load complete all as specified and directed for following capacity :- .

-

-

-

... More
5.0 HP capacity, Three phase 50 Hz AC supply

1

-

-

... More
7.5 HP capacity, Three phase 50 Hz AC supply

1

-

-

... More
10 HP capacity, Three phase 50 Hz AC supply

1

-

-

... More
15 HP capacity, Three phase 50 Hz AC supply

1

-

-

... More
Disconnecting and removing old existing non functional electric motor, of any description and in any position from existing platform for pumps and dismantling and strip opening of the motor, for cleaning oiling/greasing, Replaceing UNSV suitable size of bearing and fixing of bearing, imppler serviceable parts in position pumps and transportation to site & refixing on existing platform ,connecting with exising connections & testing on full load complete all as specified and directed for following capacity :-

-

-

-

... More
5.0 HP capacity, Three phase 50 Hz AC supply

1

-

-

... More
7.5 HP capacity, Three phase 50 Hz AC supply

1

-

-

... More
10 HP capacity, Three phase 50 Hz AC supply

1

-

-

... More
15 HP capacity, Three phase 50 Hz AC supply

1

-

-

... More
Supply fixing,connecting and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 16 Amps complete all as specified and directed. Make L&T or equievelent model of specified and directed.

1

-

-

... More
Supply fixing and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 25 Amps complete all as specified and directed .Make L&T or equievelent model

1

-

-

... More
Supply fixing and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 32 Amps. Complete all as specified and directed . Cat part No SS90935- Type ML-10 of make L&T or equievelent model of specified and directed. ,

1

-

-

... More
Supply fixing and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 50 Amps. Complete all as specified and directed .Make L&T or equievelent model

1

-

-

... More
Supply fixing and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 70 Amps. Complete all as specified and directed. Make L&T or equievelent model of specified & directed

1

-

-

... More
Supply fixing and testing in replacement of UNSV bimetal overload relays directly operated & directly mounted on ML type Power contactor for relay range of 06 to 18 Amps complete all as specified and directed. Make L&T or equievelent model.

2

-

-

... More
Supply fixing and testing in replacement of UNSV bimetal overload relays directly operated & directly mounted on ML type Power contactor for relay range of 19 to 30 Amps complete all as specified and directed. Make L&T or equievelent model

2

-

-

... More
Supply fixing and testing in replacement of UNSV bimetal overload relays directly operated & directly mounted on ML type Power contactor for relay range of 32 to 45 Amps complete all as specified and directed. Make L&T or equievelent model.

1

-

-

... More
Supply fixing and testing in replacement of UNSV digital type of size 96mm x 96mm, AC Volt meter 0- 500 Volts including wiring with 1.5 Sqmm PVC insulated stranded copper conductor cable complete all as specified and directed.

2

-

-

... More
Supply fixing and testing in replacement of UNSV digital type of size 96mm x 96mm, AC Amp meter 0- 200 Amps with including 3 Nos C.T of Ratio 200/5 of class-1.0 including wiring with 1.5 Sqmm PVC insulated stranded copper conductor cable complete all as specified and directed.

2

-

-

... More
Supply fixing and testing in replacement of UNSV insulated connectors 4 pole 100 amps rating including testing complete, all as specified and directed

1

-

-

... More
Supply fixing and testing in replacement of UNSV insulated connectors 4 pole 63 amps rating including testing complete, all as specified and directed

2

-

-

... More
Supply fixing and testing in replacement of UNSV Electronic timers 415 Volts, 50 Hz, AC supply, with delay period of 9-30-Seconds complete all as specified and directed make L&T or equievelent model of specified make as approved by the GE

1

-

-

... More
Supply fixing and testing in replacement of UNSV push button ON/OFF complete in the existing panel Complete connecting electrically all as specified and directed

5

-

-

... More
Supply fixing and testing in replacement of UNSV indicator light red/yellow /green complete in the existing panel Complete connecting electrically all as specified and directed

6

-

-

... More
Supply, fixing, connecting and testing in replacement of UNSV thermostat heating/cooling of any description complete,all as specified and directed.

2

-

-

... More
Supply, fixing, connecting and testing in replacement of UNSV MCCB Triple pole, 250 Amps 415 volts, 50 Hz having breaking capacity 35/36 KA , with adjustable thermal and fixed magnetic setting fixed in existing panel Complete all as specified and directed. Make : L&T /INDO ASIAN/Havells

1

-

-

... More
Supply, fixing, connecting and testing in replacement of UNSV MCCB Triple pole, 200 Amps 415 volts, 50 Hz having breaking capacity 36 KA , with adjustable thermal and fixed magnetic setting fixed in existing panel Complete, all as specified and directed. Make : L&T /INDO ASIAN/Havells

1

-

-

... More
Supply, fixing, connecting and testing in replacement of UNSV MCCB Triple pole, 100 Amps 415 volts, 50 Hz having breaking capacity 25 KA , with adjustable thermal and fixed magnetic setting fixed in existing panel Complete, all as specified and directed. Make : L&T /INDO ASIAN/Havells

1

-

-

... More
Supply, fixing, connecting and testing in replacement of UNSV Honeywell CN7510A2001 valve actuator suitable for existing air cooled air conditioner plant 45 TR complete, all as specified and directed. (Installed at Large Optics Building)

1

-

-

... More
Supplying, installing, testing & commissioning in replacement of 10 HP horizontal centrifugal pump, 3 phase, 50 hz as per existing head complete all as specified and directed.

2

-

-

... More
Supplying, installing, testing & commissioning in replacement of existing BMS (Building Management System) which monitor sensors that measure temperature, humidity, system pressure etc.including existing software testing, controller/server & sensors testing work at site complete all as specified and directed. (Installed at Large Optics Building)

1

-

-

... More
Disconnecting, dismantling and taking out the existing Air conditioner Split type of any description, any make and in any position 1.5 TR/2 TR capacity, both indoor and outdoor unit single phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete, all as specified and directed. Note: (Applicable for Sch ‘A’ Item No.1& 2). (i) Window/Split type AC's shall be taken from department on "as and where installed" basis. (ii) Window/Split type AC's are to be maintained for heating as well cooling , where this provision is in the machine. (iii) The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, cooling coil & blower motor) under relevant items shall be included in item No.1&2). (iv) The contractor shall ensure and asses at the site any initial maintenance required, to make the all Window/Split type AC's in proper working condition, at the time of taking over and he shall be laible to make all listed handed over units functional. (ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item.

350

-

-

... More
Supply only repaired compressor sealed unit of suitable capacity/ model in the unit properly for 1.5/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )

11

-

-

... More
Supply only new Rotory type compressor sealed unit of suitable capacity/ model in the unit properly for 1.5 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )

7

-

-

... More
Supply only new Rotory type compressor sealed unit of suitable capacity/ model in the unit properly for 2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )

7

-

-

... More
Supply only new condensing coil unit for Split type AC of any type/ any capacity complete, all as specified and directed. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )

7

-

-

... More
Supply only blower motor including fan blade, capacitor complete suitable for windo type AC2 ton/ capacity 1/8 HP, 220 Volts, single phase complete, all as specified and directed.

3

-

-

... More
Supply only blower motor including fan blade, capacitor complete suitable for split type AC 1.5ton capacity 1/8 HP, 220 Volts, single phase complete, all as specified and directed.

6

-

-

... More
M&L for charging refrigerant gas in the system of window/Split type AC of 1.5/2.0 ton capacity complete, all as specified and directed. (Note : The refrigerant gas measured and paid separately under relevant items as applicable as ‘supply only’).

40

-

-

... More
M&L for replacement of unserviceable starting capacitor 80/100 MFD 230 V AC for window/Split type AC 1.5 Ton/2.0 Ton capacity/water cooler complete, all as specified and directed. (Make : Universal/Sarda )

11

-

-

... More
M&L for replacement of unserviceable running capacitor 36/45/50 MFD 230 V for window/Split type AC 1.5 Ton/2.0 Ton capacity complete, all as specified and directed. (Make : Universal/Sarda )

21

-

-

... More
M&L for replacement of unserviceable overload protection coil (1622) 230 Volts for window/Split type AC 1.5 Ton/2.0 Ton capacity complete, all as specified and directed.

5

-

-

... More
M&L for replacement of unserviceable Relay (1622) suitable for window/Split type AC 1.5 Ton/2 Ton capacity complete, all as specified and directed.

12

-

-

... More
M&L for replacement of unserviceable capillary tube and stainer for window/Split type AC of 1.5 ton/2 ton capacity complete, all as specified and directed.

23

-

-

... More
M&L for replacement of unserviceable PVC air filter for Split type AC of 1.5 ton/2.0 ton capacity complete, all as specified and directed.

23

-

-

... More
M&L for replacement of unserviceable capacitor for blower motor suitable for window /Split type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed.

5

-

-

... More
M&L for replacement of unserviceable fan blade for blower motor suitable for window /Split type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed.

9

-

-

... More
M&L for replacement of unserviceable swinging motor with louvers as per existing make for Split type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed.

9

-

-

... More
M&L for replacement of unserviceable remote control assembly with PCB plate complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed .

9

-

-

... More
M&L for replacement of unserviceable Inverter PCB for Indoor complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed .

8

-

-

... More
M&L for replacement of unserviceable Inverter PCB for outdoor complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed .

7

-

-

... More
M&L for replacement of unserviceable LCD / LED display unit for Window/split type AC 1.5 / 2.0 ton capacity complete, all as specified and directed.

10

-

-

... More
M&L for replacement of unserviceable 15/20 mm bore PVC flexible conduit complete, all as specified and directed.

90

-

-

... More
Supply and fixing in replacing refrigerant copper tubing 5/8" / 1/2" dia (as per existing one) with 22 gauge , fixed on wall / ceiling with saddle as per site requirement including making joints by brazing / flairing and checking for any leakage complete, all as specified and directed.

70

-

-

... More
Supply and fixing in replacing refrigerant copper tubing 3/8" / 1/4" dia (as per existing one) with 22 gauge , fixed on wall / ceiling with saddle as per site requirement including making joints by brazing / flairing and checking for any leakage complete, all as specified and directed.

80

-

-

... More
Supply and fixing in replacment foam type insulation sleeve for copper tubing 5/8" / 1/2"/ 3/8" / 1/4" dia (as per existing one) binding and securing the insulation firmly with copper tubing as per site requirement complete, all as specified and directed.

130

-

-

... More
M&L for replacement of unserviceable reverse cycle valve in window/Split type AC of 1.5 / 2 TR cap. and welding, brazing with copper tubing and testing complete all as specified and directed. Make : Renutrol/Pacific

6

-

-

... More
M&L for replacement of unserviceable internal wiring of AC, water cooler, refrigerator of any capacity and rewiring the same with 2.5 Sqmm size multi stranded copper cable incl testing checking etc complete all as specified and directed.

4

-

-

... More
Supply only refrigerant gas R-22.

160

-

-

... More
Supply only refrigerant gas 134A.

7

-

-

... More
Supply only refrigerant gas R-407/R-410 (HYDRO CARBON)

220

-

-

... More
M&L for replacement of angular valve of size 1/2" suitable for split type AC complete. all as specified & directed by Engineer-in-Charge

4

-

-

... More
M&L for replacement of angular valve of size ¼" suitable for split type AC complete all as specified & directed.

4

-

-

... More
M&L for replacement of angular valve of size 5/8" suitable for split type AC complete all as specified & directed.

4

-

-

... More
M&L for replacement of angular valve of size 3/8" suitable for split type AC complete all as specified & directed.

4

-

-

... More
Supply only Remote control for split/ Window type AC of LG/Samsung/existing make of 1.5 TR/2 TR with battery complete all as specified & directed..

4

-

-

... More
M & L for dismantling of unserviceable voltage stablizer of capacity 3 KVA/4 KVA/5 KVA in various location for repair/replacement of unserviceable parts, cleaning, servicing, checking, reassembling, testing and handed over to MES in serviceable condition complete all as specified & directed. (Note :- The spare parts measured and paid separately as supply only rates. Rates for fixing of spare parts under relevant items shall be included in item)

30

-

-

... More
Installation only split type AC including indoor/outdoor unit of capacity 1.5 Ton/2 Ton after carried out the repair under item No.105 & 106 at new location as directed including providing necessary chiseling/ cutting for fix the indoor/outdoor unit by means of suitable size of nut, bolt, angle iron structure, masonry work and making good the disturbed surface with PCC, plastering,white wash works,testing & checking complete all as specified & directed.(Note :- The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, blower motor and nut bolt angle iron structure) under relevant items shall be included in this item) complete all as specified & directed.

11

-

-

... More
Supply &Fixing in replacement of unserviceable Oudoor unit body complete with out compressor unit suitable for existing Split type AC of 1.5 TR capacity,complete all as specified & directed.

7

-

-

... More
Supply &Fixing in replacement of unserviceable indoor unit body complete suitable for existing Split type AC of 1.5 TR capacity, complete all as specified & directed.

7

-

-

... More
Supply &Fixing in replacement of unserviceable mild steel work as split type AC outdoor/water cooler wheel stand /supporting /protection cage etc. of suitable size of flat iron/Angle iron etc.,cut to shape, including bending and welding as necessary, etc.conforming to Fe.290.Gde-E-165, with and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete, all as specified and directed.

20

-

-

... More
Supply &Fixing in replacement of unserviceable plug top 3 pin, 15/16 Amp capacity complete all as specified and directed. Make : Anchor (Penta deluxe) or equivalent as approved by GE.

100

-

-

... More
Disconnecting and removing the water and electric connections carefully from the existing Geyser of capacity 25/50 ltrs, any make and taking out the same in any position from the existing location. cleaning and de-scaling the inner tank using de-scaling solution mixed with water in suitable proportion till the complete deposits /scale is removed as approved by Engineer-in-Charge, brazing for stopping leakage of copper inner tank/gas welding for inner steel tank, re- assembling the complete Geyser after cleaning, Fixing and installation of Geyser in position and testing to the entire satisfaction of Engineer-in-Charge. Opening the Geyser for inspection, repairs and reassembling the same as per the original assembly after repairs/ replaceing the wourn out unserviceable parts with new parts as ordered including re-fixing same position of the Geyser and making electric connection, water inlet and outlet connection, testing and checking of all the functioning of water inlet outlet valves connected with geysers.complete all as specified & directed. Note :- Spare parts if any requires replacement shall be measured and paid for separately.

200

-

-

... More
Supply only Rubber PVC gasket to ensure water tightness for 25/50 liters capacity complete all as specified & directed.

20

-

-

... More
Supply only MS base plate cup any type with screws of suitable size as per requirement complete all as specified & directed.

20

-

-

... More
Supply only Heating element of the 1.5/ rating as required at site including rubber washers of any make and type complete all as specified & directed.

35

-

-

... More
Supply only Heating element of the /2 KW rating as required at site including rubber washers of any make and type complete all as specified & directed.

15

-

-

... More
Supply only Steel inner tank of 25 litre capacity geyser tank by made out of steel sheets appropriate thickness complete all as specified & directed.

7

-

-

... More
Supply only Steel inner tank of 50 litre capacity geyser tank by made out of steel sheets appropriate thickness complete all as specified & directed.

3

-

-

... More
Supply only Insulating material (glass wool for Geyser) complete all as specified & directed.

10

-

-

... More
Supply only Non return valve 15 mm dia cast copper alloy ISI mark complete all as specified & directed.

20

-

-

... More
Supply only Safety valve/Fusible plug 15mm complete all as specified & directed.

20

-

-

... More
Supply only Chromium plate copper connecting tube 450 mm long with two brass adopters suitable for 15 dia pipe and connecting up complete with washers complete all as specified & directed.

20

-

-

... More
M&L in replacement of unserviceable bottom plate of geysers 25/50 liters capacity, same sizes and shape complete all as specified & directed.

20

-

-

... More
M&L in replacement of unserviceable air release valve 15 mm bore for geyser as per existing type complete all as specified and directed.

20

-

-

... More
Supply only assembly type round heating element of the 1.5KW rating as required at site including rubber washers of any make and type complete all as specified & directed.

30

-

-

... More
Supply only assembly type round heating element of the 2 KW rating as required at site including rubber washers of any make and type complete all as specified & directed.

10

-

-

... More
Supply only PVC hot and cold connecting tube 600 mm long with two brass adopters suitable for 15 mm dia pipe and fixing in position ,superior quality complete all as specified & directed.

20

-

-

... More
Supply and fixing sheet metal box with MCB 20A and with 3 pin socket and top etc complete all as specified & directed superior quality as approved by Engineer-in-charge.

40

-

-

... More
Supply only Thermostat cut out bellow type with setting range 00°C to 100°C suitable for 230 volts AC, electric supply complete all as specified and directed, Make – Recold / Bajaj,/ Daspass

20

-

-

... More
Supply and fixing fastener of size 3" /4" fixing of geyser complete all as specified and directed.

40

-

-

... More
Supply and fixing 'U' assembly 6 hole for 25 ltr geyser complete all as specified and directed.

5

-

-

... More
Supply and fixing 'U' assembly 6 hole for 50 ltr geyser complete all as specified and directed.

5

-

-

... More
Supply and fixing 'U' assembly 9 hole for 25 ltr geyser complete all as specified and directed.

5

-

-

... More
Supply and fixing 'U' assembly 9 hole for 50 ltr geyser complete all as specified and directed.

5

-

-

... More
Disconnecting , taking down & removing carefully the existing ceiling fan , etc. of any description, any sweep and from any position / locations (i.e. Md Accn/ OTM Accn / Md Hostel/ Workshop/ Installations etc) for repairs / servicing / overhauling / painting / numbering etc., dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging / fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction of Engineer-in-Charge complete, all as specified and directed.

350

-

-

... More
Disconnecting , taking down & removing carefully the existing exhaust fans etc. of any description, any sweep and from any position / locations (i.e. Md Accn/ OTM Accn / Md Hostel/ Workshop/ Installations) for repairs / servicing / overhauling / painting / numbering etc., dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging / fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction of Engineer-in-Charge complete, all as specified and directed.

120

-

-

... More
Disconnecting,taking down and removing carefully the existing table fan, Air circulator wall mounting fan,pedestal fan, of any description, any sweep and from any position / locations for repairs / servicing / overhauling / painting / numbering etc., dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, connecting the fans to existing electric sources and testing at site to the entire satisfaction of Engineer-in-Charge complete, all as specified and directed. Note for item 1 to item 3 here in before : (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation to & fro of fans to workshop if required and approved by the Engineer-in-charge for necessary repairs. (iv)Cost of minor repair i.e. loose connection tightening, oiling greasing, tightening nut- bolts, insulating wire etc deemed to be inclusive in the item rate above. (v) Writing of fan No. and painting of fans shall be measured and paid for separately under appropriate item of Sch ‘A’

30

-

-

... More
Supply only the following new parts suitable for the ceiling/ exhaust fans, wall bracket fans & pedestal fans, air circulating fans etc. of any description, any sweep :- Note :- Fixing & testing charges of these items are deemed to be included in the rates quoted by the tenderer for Sch ‘A’ item No. 153 and 154 above

-

-

-

... More
Supplying only ball bearing No 6200(Make SKF/NRB/NBC)

10

-

-

... More
Supplying only ball bearing No 6201 (Make SKF/NRB/NBC)

10

-

-

... More
Supplying only ball bearing No 6202 (Make SKF/NRB/NBC)

10

-

-

... More
Supplying only ball bearing No 6203 (Make SKF/NRB/NBC)

10

-

-

... More
Supply only gun metal bushes of any description and size to suit existing motor shaft.

40

-

-

... More
Supplying only capacitor of capacity 2.5 mfd (PVC body) (Make:- EPCOS/JYOTI/ USHA)

50

-

-

... More
Supplying only capacitor of capacity 4 mfd (PVC body) (Make:- EPCOS/JYOTI/USHA)

50

-

-

... More
Supply only complete hanging assembly set comprising with rubber reel, MS clamps, nuts, bolts with lock pins suitable for any type of fans & down rods of length 300mm.

40

-

-

... More
Supplying only aluminium cast metal fan blade assembly with necessary MS nuts, bolts & washers suitable for ceiling/ exhaust fans, wall bracket fans & pedestal fans, air circulating fans of any descriptions & of any mm sweep. Note: (i) Set of three blades shall be measured as one unit. (ii) Make of the blade assembly shall be as approved by GE

40

-

-

... More
Supply only PVC insulated and sheathed, round flexible cable, three core of size 0.50 Sqmm with copper conductor in pieces for connecting fans. ( Make :Havell’s / Finolex / Gloster / National/ Plaza )

100

-

-

... More
Supply only MS tube medium grade 15mm dia duly finished with white colour two coats over a coat of red oxide cutting in desired length from 300mm to 1500mm, cutting slot and drilling hole for down rod of fan complete all as specifieda and directed.

20

-

-

... More
Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire (Make : Atlas/Finolex/Devi Dayal)as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of Engineer-in-charge for the following Fans:-

-

-

-

... More
Rewinding of motor of ceiling fans 1200 mm sweep.

18

-

-

... More
Rewinding of motor of ceiling fans 1400 mm sweep.

8

-

-

... More
Rewinding of motor of exhaust fan of 230/300 mm sweep.

4

-

-

... More
Rewinding of motor of exhaust fan of 450 mm sweep.

4

-

-

... More
Rewinding of motor of wall mounted fan of 400 mm sweep.

2

-

-

... More
Rewinding of motor of air circulating fan of 610 mm sweep.

2

-

-

... More
Rewinding of motor of table fan/ pedestal fan of 400 mm sweep.

2

-

-

... More
Taking down existing worn out louvers of any description , in any position and supplying & fixing new louvers for exhaust fan of 230/300mm/ sweep complete all as specified & directed. ( Note: The louvers shall be of shape, size and pattern as approved by the Engineer-in-Charge duly painted with two coat of synthetic enamel paint over a coat of red oxide primer)

15

-

-

... More
Taking down existing worn out louvers of any description , in any position and supplying & fixing new louvers for exhaust fan of 450mm sweep complete all as specified & directed. ( Note: The louvers shall be of shape, size and pattern as approved by the Engineer-in-Charge duly painted with two coat of synthetic enamel paint over a coat of red oxide primer)

5

-

-

... More
Disconnecting and taking out old existing unserviceable ceiling fan modular regulator of any description and in any position/ location and supply and fixing ceiling fan modular regulator electronic, step type, 1M size modular type , suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply complete all as specified and directed. (Make :- Anchor/Cona/Havells/Legrand/HPL)

60

-

-

... More
M & L for painting of existing fans of any description of ceiling fan of 1200/1400mm sweep with applying one coat of synthetic enamel paint (White) by spray machine including preparation of existing decorated surfaces of fans complete, all as specified and directed.

40

-

-

... More
M & L for painting of existing fans of any description of exhaust fan of 230/300/450mm sweep with applying one coat of synthetic enamel paint grey by spray machine including preparation of existing decorated surfaces of fans complete, all as specified and directed.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.