Military Engineer Services Tender

View complete overview of Uttarakhand MES Tender

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date13 Feb 2025
Closing Soon11 Mar 2025
Tender Amount₹ 42,01,960 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.

26.78

-

-

... More
M&L for hardcore broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed

26.07

-

-

... More
M&L for cement concrete (1:4:8), type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed

4.8

-

-

... More
M&L for 100 mm thick plain cement concrete (1:4:8), type D-2 (using 40mm graded stone agg as in sub base finishing the surface even and rough to receive floor finishes complete all as specified and directed.

159.96

-

-

... More
M&L for RCC (design mix) M-25 (using 20mm graded stone aggregates) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles, raft etc and mass concrete complete all as specified and directed.

15.5

-

-

... More
M&L for RCC (design mix) M-25 (using 20mm graded stone aggregates) as in floor/ roof beam, cantilevers, lintel over 1.5m span complete all as specified and directed.

10.45

-

-

... More
M&L for RCC (design mix) M-25 (using 20mm graded stone aggregates) as in columns, pillars, piers, posts and struts complete all as specified and directed.

14.53

-

-

... More
M&L for RCC (1:2:4) Nominal mix (using 20mm graded stone aggregates) as in Chajjas/ fins/ facia of roof slab complete all as specified and directed.

1.08

-

-

... More
M&L TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.

4169.16

-

-

... More
All as per item No 10 here-in- before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.

1403.48

-

-

... More
Use and waste of form work for sides of concrete foundation footing, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter roughed finished surface of concrete complete all as specified and directed.

87.9

-

-

... More
Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. finished fair and even complete all as specified and directed.

93.89

-

-

... More
Use and waste for form work to sides of pillars, posts, struts columns, square, rectangular or polygonal etc finished fair and even complete all as specified and directed.

166.4

-

-

... More
M&L for formwork for rough finish to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.

10.78

-

-

... More
S&F Pre-painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa, AZ-150 as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.

212.82

-

-

... More
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, AZ-150 as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.

39.18

-

-

... More
M&L for75 mm thick PCC (1:3:6), type C-2 using 40mm graded stone aggregate as in plinth protection, surface finished even & smooth without using extra cement, with and including joint filling (Size 30mm deep x 10mm wide) with sealing compound grade-A at 3m interwal and corner complete all as specified and directed. Note : Joint to be provided at each interval of 3m and corner and cost of the same deemed included in quoted rate.

61.5

-

-

... More
Providing & fixing of windows made of pre-painted steel (Base steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 52 x 25mm. Outer frame & mullion sections to have rebate for glazed shutters, fly mesh and 20 mm provision for guard bars/ grills fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2nos of heavy-duty stain less steel pivot hinges shall be provided per shutter. The windows should be panelled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self-expanding, screws.Including 10mm square guard bars with 6” (152.4mm) pitch, complete all as spd and directed.

13.23

-

-

... More
Material & labour for Rendering 10 mm thick CM 1:6 using water proofing liquid compound as per manufacturer's instructions on brick or concrete surfaces finished even & smooth without using extra cement including scaffolding complete all as specified and directed.

331.7

-

-

... More
M&L for preparation of newly plastered surface of internal wall by application of 1 mm thick wall care putty to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacture of paint and as directed .

331.7

-

-

... More
S&F rolled mild steel section for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W(Gde-E-250) quality-A complete all as specified and as directed. Note : The rates quoted allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete.

2114.23

-

-

... More
S&F mild steel plate (plain or chequered) channels,square cut or notched (ordinary and counter sunk ) forming holes, with riveted,bolted or weleded attachement confirming to Fe- 410-W (Gde E-250) quality A complete all as specified and directed.

488.33

-

-

... More
S & F mild steel screw bolts 16 to 20mm dia ( Machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nuts exc 15 cm and n exc 22.5 cm long, complete all as specified and directed

65

-

-

... More
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified

150.01

-

-

... More
S&F 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15 mm screed bed 1:6 cement mortar complete all as specified and directed.

7.45

-

-

... More
M&L for damp proof course (DPC), 40 mm thick, cement concrete (1:2:4), type B0, using 12.50 mm graded stone aggregate, mixed with WPC (liquid type) @ 200ml per 50 Kg of cement or as per manufacturer’s instructions, including necessary formwork, complete all as specified and directed. Note:- WPC (liquid type) shall be measured and paid separately as supply only.

18

-

-

... More
Supply only WPC integral water proofing compound (Liquid type) complete all as specified and directed.

3.3

-

-

... More
M&L for PCC (1:2:4) type B-0, using 12.5mm graded stone aggregates, as in roof kerb/ benching/ coping, bed plates, for fixing of hold fast, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed.

5.2

-

-

... More
M&L hand made sliding bolts; clamps; hold fasts; hooks for hanging fans and similar small articles complete all as specified.

10

-

-

... More
M&L for Machine cut kota stone slab flooring 20-25mm thick laid over and including 20 mm thick screed bed in CM (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.

139.16

-

-

... More
M&L for machine cut Kota stone slab 20-25 mm thick as in vertical surfaces such as risers of steps, skirting, dado etc over and including 10mm cement screed bed laid in CM (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing complete all as specified and directed.

7.65

-

-

... More
M&L for 100 mm thick cement concrete type B-2 (1:2:4) using 40 mm graded stone aggregate including spike rolling complete all as specified.

15.6

-

-

... More
M&L for 15mm thick plastering on fair faces of brick wall in two layers, Ist layer 10mm thick CM (1:6), and IInd layer 5mm thick CM (1:4), surface finished even and fair mixed with @ 200ml per bag WPC (liquid type) complete all as specified and directed. Note :- WPC (Liquid type) shall be measured and paid separately as supply only.

545.55

-

-

... More
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces and preparation of new plaster surface complete all as specified and directed.

545.55

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm in soft/ disintegrated rock complete all as specified and directed

31.52

-

-

... More
Removing surplus excavated soft/ disintegrated rock to a distance exc 250 m and not exceeding 500m & depositing where directed at a level n.exc 1.5m above the starting point complete.all as specified and directed.

27.6

-

-

... More
M&L for brick work with old size full brick subclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.

68.76

-

-

... More
M&L for 40 mm thick PCC (1:2:4) type B1 (20 mm graded stone agg) as in flooring, as base to receive floor tile complete all as specified and directed.

139.16

-

-

... More
S&F steel rolling shutters, gear operated type with chain wheel and hand chain, as specified including top cover, anchoring rod, hasp and staple, Safety lever locks mild steel with 4 levers and one shop coat of primer, erected in position as indicated for following thickness of lath complete all as specified and directed:-

-

-

-

... More
1.25mm thick lath

16.8

-

-

... More
Supply only Ball bearing for rolling shutters complete all as specified and as directed.

6

-

-

... More
S&F factory made Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with hold fasts and brackets, complete all as specified and directed.

16.8

-

-

... More
S&F 18 mm thick with min density 600 Kg/Cum LEAD FREE PVC Celuka ply of both side plain white colour fixed with screws, solvent cement/ adhesive to make kitchen/bed rooms cabinet and cupboard shutters and shelves complete as per manufacturer’s specifications complete all as specified and directed

49.72

-

-

... More
S&F 18 mm thick with min density 600 Kg/cu.m LEAD FREE PVC Celuka ply of single side rigid laminate of approved color and other side plain white colour fixed with ss screws ans solvent cement/ adhesive to make kitchen cabinet shutters complete as per manufacturer’s instructions complete all as specified and directed

33.52

-

-

... More
S&F 6 mm thick with min density 600 Kg/cu.m LEAD FREE PVC ply fixed with ss screws and solvent cement/ adhesive to make wall mount kitchen cabinet back sides complete as per manufacturer’s specifications complete all as specified and directed

33.52

-

-

... More
S&F Auto closing hinges 35mm of 0 crank( KH-001) or 8 crank (KH-002) openable at 110 degree for kitchen cabinet shutters complete in all respect and fixed in position all as specified

60

-

-

... More
S&F D-type cabinet handles premium quality, stainless steel 304/gloss chrome/SN finished 150mm long matt finished complete fixed in position all as specified.

30

-

-

... More
S&F in repairs for stainless steel non magnetic curtain rod of 25mm dia with and including fixing brackets and decorative type knobs (as approved by AGE (I)/ GE both side of each rod complete all as specified and directed. Note: - Measurement will be taken between end point of knobs.

10.8

-

-

... More
Material & labour for Rendering 5 mm thick CM 1:3 on ceiling of brick or concrete surfaces finished even & smooth without complete all as specified and directed.

10.78

-

-

... More
M&L for two coats of white wash on new ceiling surfaces including preparation of surfaces complete all as specified and directed. Note :- The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per satifaction of Engr-in-Charge.The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted.

10.78

-

-

... More
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in soft/disintegrated rock complete all as specified and directed.

52

-

-

... More
M&L for 60 mm thick coloured rubber moulded glossy finish machine pressed precast concrete interlocking paver block, M-35 Grade with grey cement & pigment any shape and size confirming to IS 15658-2006 with and including over 25 mm thick sand cushining complete all as specified and directed.

52

-

-

... More
M & L for providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in sides of rounded or chamfered on edges complete all as specified and directed

1

-

-

... More
M&L for PCC (1:2:4) type B-1, using 20mm graded stone aggregate as in surface channel and drain including saucer drain and toe wall etc complete all as specified and directed.

1.06

-

-

... More
M & L for Rendering 15mm thick on fair face of brick or concrete surface incl finish even and smooth(without using extra cement) in CM 1:4 complete all as specified and directed..

6.44

-

-

... More
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc.

14

-

-

... More
M&L for precast RCC (1:2:4) type B1, (using 20mm graded stone aggregates) as in cover slab (for drain) and set in CM (1:4) including necessary fair finish formwork complete all as specified and directed.

2

-

-

... More
E/M Portion M&L for point wiring with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in and including concealed PVC conduit "medium grade" (ISI marked), not less than 20mm dia duly concealed on wall/ ceiling or above false ceiling with fittings medium grade (Color coding of wires shall be phase, neutral and earth wire all as specified) sunk metal flush box suitable for modular fixture with and including decorative polycarbonate frame for housing modular switches, sockets, fan regulators etc including white cover plate complete all as specified and directed for following:- Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface in CM (1:3) and matching with the existing surface deemed included in quoted rates. (ii) If the contractor fail to make good the disturbed surface of wall/ ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery of @ Rs. 50/- per RM will be made from payment due to the contractor. In case of any dispute the decision of Accepting Officer will be final and binding.

40

-

-

... More
One 5/3 pin socket out let 5/6 Amp on independent board.

12

-

-

... More
Descrition same all as per item No 60 above, but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.

6

-

-

... More
S&F switch piano flush type 230 Volts AC single pole, one way 5/6 Amps ISI Mark all as specified and directed.

52

-

-

... More
S&F switch piano flush type single pole, one way 15/16 Amps all as specified and directed.

6

-

-

... More
S&F socket outlet flush type 3/5 pin 5/6 Amps 230V AC all as specified and directed.

12

-

-

... More
S&F socket outlet flush type 5/6 pin 15 Amps 230V AC all as specified and directed.

6

-

-

... More
M&L ceiling rose 3 terminal / PVC/ polycarbonate, isolated body all as speccified and directed.

28

-

-

... More
S&F Angle holder metal ring insulated body with back plate suitable for batten fitting complete all as spd and directed

12

-

-

... More
S&F surface mounted LED luminarie 20 Watt with all accessories having aluminium aluminium extruded chanbel with difuser for glaree free light, high lumen output, driver 0.95 having overvoltage protection , level 7-10 KV thermal short circuit ptotection THD10%, made up of long life LED chips (SMD) in modular with Ra70 and lumen effieiency 120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose all as directed.

6

-

-

... More
S&F LED Bldg Security light 20W housing made out of die cast aluminium alloy with tougned glass , IP 65 protection having clamp for mounting on building wall working on 240V AC 50 Hz , 20 Watts consisting of reflective lens, wired with appropriate driver PF0.95 having over voltage protection up to 400 volts, surge protection level 7 - 10 KV, thermal short circuit protection THD10%, made up of long life LED chips (SMD) in modular with Ra70 and LED lumen efficiency 120 lumen Per watt, including fixed on wall with 02 Nos MS Clamps made of 40x6 mm FI and bracket made of 40 mm dia light grade GI Pipe bend to shape, not less than 1.2 m long including connecting with 02 single core PVC insulated copper conductor cable 1100 v grade size 1.5 sqmm complete all as specified and directed. Note : Connection to luminaire shall be done in suitable PVC connector within the bracket/luminaire end and are inclusive in above.

6

-

-

... More
S&F MCB DB SPN 8 way with 200 amps 240 volts rated copper busbar in sheet steel enclosure double door type complete all as specified & directed.

3

-

-

... More
Supply & fixing MCB , SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed.

15

-

-

... More
Supply & fixing MCB, SPN, AC, 240 volts of 40 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.

3

-

-

... More
S&F exhaust fan steel body with louver shutter, heavy duty, AC, single phase, 230 V, of size 300 mm sweep, 1200 RPM and connecting up including provision of cable from ceiling rose/ connector to exhaust fan, making holes and making good the distrubed surface of wall complete all as specified and directed.

4

-

-

... More
S&F service cable 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended with insulating hanger not more than 1 mtr apart including 4 mm dia suspension wire alongwith 10 Sqmm twin core flat cable all as specified and directed.

150

-

-

... More
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground, earth pit not less than 2.25 mtr depth below ground level at any type of strata with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate, connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC (1:3:6) type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM (1:4) funnel with wire mesh, RCC pit cover of 320 x 320 x 80mm size PCC (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.

3

-

-

... More
S&F complete air termination assambly comparising of single pointed air termination aluminium rod 12mm dia, 300mm long, GI pipe (20mm dia and 1.5m length), GI socket/reducer ( 20mm dia), aluminium gutty with inner and outer threaded to fix the rod including PCC/ brick massonry block & wooded gutaka for fixing stand post of GI pipe in PCC/ masonary block and taking out existing one complete all as specified and directed.

10

-

-

... More
S&F in repair test point terminal box made of gun metal or phosphorous brounze of size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed

6

-

-

... More
S&F in repair aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed

40

-

-

... More
S&F in repair earth continuity conductor or main earthing lead 32x 6 mm GI strip laid in pipe / fixed to poles or any other indicated situation including jointing using by GI nuts, bolts and washer in addition to welding complete all as shwon in drawings, & all as specified and directed .

45

-

-

... More
M&L for earthing complete with galvanised steel earth plate electrode 600mm X 600mm X 6mm thick buried directly in ground vertically earth pit not less than 2.25 meter deep below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI earth strip of size 25x4 mm as earthing lead by means of bolts, nuts and washers all as shown in electrical plate No 3 of MES Scedule part I (2009) with conected to eath test point including adequate quantity of charcoal dust and comman salt, PCC (1:3:6) type C-1 chamber and for earth pit with 40x40x6mm mild steel angle iron frame for cover. precast RCC cover 40mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia round bars both ways with MS handle 8 mm dia. PGI funnel and wire mesh 20 mm dia GI pipe medium grade for watering and 32mm dia medium earth lead protection pipe complete all as specified and directed. Note: GI earth strip and protection pipe upto and including 7.5m is deemed included in unit rate quoted by contractor.

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.