Military Engineer Services Tender
View complete overview of Uttarakhand MES Tender
Military Engineer Services - MES Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date5 Jan 2024
Closing DateCancelled
Tender Amount₹ 1,18,00,000
Costs
EMD
₹ 1,93,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_635995_1Tender No
95244/RKE/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
PROVN OF OVER HEAD WATER TANK 50000 GALAN NEAR MES PUMP HOUSE NO 2 AT SAHARANPUR UNDER GE ROORKEE
BOQ Items
... More
Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified
39.38
-
-
... More
M&L for excavation in trenches n. exc 1.5mtr wide and n. exc 1.5mtr deepth for foundation etc or for shaftswells cesspits manholes pier holes etc n exe 10 sqm on plan and n exe 1.5 mte in depth and getting out in soft/loose soil.
6.21
-
-
... More
M&L for ATT of the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area
306.98
-
-
... More
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
111.01
-
-
... More
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.(up to 7.50M)
54.75
-
-
... More
Formwork to sides of pillars, posts, struts, piers, columns and stanchions(up to 7.50M)
84.77
-
-
... More
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.(7.50 to 15.0M)
54.75
-
-
... More
Formwork to sides of pillars, posts, struts, piers, columns and stanchions(7.50 to 15.0M)
84.77
-
-
... More
Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter(15.0 to 18.0 M)
199
-
-
... More
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.(15.0 to 18.0M)
21.9
-
-
... More
Formwork to sides of pillars, posts, struts, piers, columns and stanchions(15.0 to 18.0M)
33.9
-
-
... More
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
201.87
-
-
... More
M&L for PCC 1:4:8 type D2 using 40mm crushed stone agregate as in foundation filling and mass concrete all as specified.
24.95
-
-
... More
M&L for Reinforced cement concrete design mix (M30)in:- Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as directed and specified by Eng-In-Charge
78.86
-
-
... More
M&L for Reinforced cement concrete design mix (M30)in:- Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses all as directed and specified by Eng-In-Charge
39.46
-
-
... More
M&L for Reinforced cement concrete design mix (M30)in:- Columns, pillars, piers, posts and struts all as directed and specified by Eng-In-Charge
22.75
-
-
... More
M&L for Reinforced cement concrete design mix (M30)in:-Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as directed and specified by Eng-In-Charge
50.48
-
-
... More
M&L TMT for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips (up to 7.5M)
18230
-
-
... More
M&L for TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips(up to 7.5M)
16550
-
-
... More
M&L TMT for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips (7.5 to 15.0M)
16550
-
-
... More
M&L TMT for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips(15.0 to 18.0M)
6620
-
-
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm
72.48
-
-
... More
M&L for Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
1500
-
-
... More
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (sq/rect.) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set & jointed in neat cement slurry and pointed in white or coloured cement to match incl over 15 mm thick cement sceed bed in CM 1:3 all as directed by Engr-In-Charge
63.58
-
-
... More
M&L for preparation of surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) using roller over a coat of 2mm wall care putty in two layers and a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge.
Note:- 1. The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction to the satisafaction of Engineer-in-Charge before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. (ii) The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE before commencement of work. (iii) All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture.
(iv) After carrying out preparation of surface, the same shall be got approved from GE before application of emulsion for each building.
(v) The colour / shade will be all as approved by GE
(vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor complete all as specified and directed.
750.99
-
-
... More
S&F for Cast iron pipes with spigot and socket ends, vertically cast, class A, in any length, laid in trenches 200mmdia Delivery pipe
22
-
-
... More
Fixing only sluice valve with flanged ends, any pattern Valve 200mm dia
1
-
-
... More
S&F for Cast iron pipes with spigot and socket ends, vertically cast, class A, in any length, laid in trenches CI pipe 200mm dia inlet pipe
25
-
-
... More
S&F for Cast iron pipes with spigot and socket ends, vertically cast, class A, in any length, laid in trenches CI pipe150mm out pipe
22
-
-
... More
S&F for Cast iron pipes with spigot and socket ends, vertically cast, class A, in any length, laid in trenches
25
-
-
... More
M&L for Framed work such as grills, gratings,etc. with end of bars shouldered and/or riveted or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar works conforming to Fe 290 Gde E1-65
4260
-
-
... More
M&L Water level indicator connected with all accessories all asspecfied and directed by Engineer- In- charge
1
-
-
... More
M&L for brick work with subclass 'B' bricks straight or curved on plan exe 6mm mean radius built in cm 1:6
3.11
-
-
... More
M&L for hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface
22.5
-
-
... More
M&L for 100 mm thick PCC (1:2:4) type B-2 as in plinth protection complete all as specified.
225
-
-
... More
Material & labour for cast Iron pipes, vertically cast, class 'B' type, both ends flanged and drilled, including jointing, 150 mm (6") dia erected alolng the pillar/beam of Over head tank, with clamps saddled-on pillar duly screwed in with nuts, bolts & washers, complete all as specified and directed by Engr-in-Charge at site.
93
-
-
... More
Supply and fixing sluice valve of size 150 mm dia, connecting & testing both ends flanged and drilled cast iron body class PN-1.6 confirming to IS- 14846/2000 complete with gun metal spindle including necessary nut bolt etc for the following sizes (Note :- for these sluice valves which are fixed with pillar of over head tank work involve such as breaking of PCC/Lead flange joints will be deemed to include in the rate quoted & contractor will also repair the damaged floor etc, to match with existing. Make: L&T/Kalpana/Kirloskar
3
-
-
... More
M&L for for CI bends, tapers, Tee pieces (Single & double branch) any type and angle /radius and straight connecting pieces but all ends flanged upto 150 bore in mm complete all as specified and directed.
805
-
-
... More
M&L for connecting pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth upto 150 mm bore complete all as specified and directed
197.2
-
-
... More
M&L for joint rubber or fibre board gasket for flanged pipe and fittings 150 mm bore complete all as specified and directed
34
-
-
... More
Supply & fix single pointed air termination aluminium rod 12mm dia, 300 mm long, at the top of the Over head tank, complete all as specified and directed at site.
Note :- the finial should not be in contact with the RCC structure, insulating medium shall be kept all along the lightening conductor which runs along the RCC beam
2
-
-
... More
S&F Aluminium Strip 25mm x 3.15mm complete with shadles and fixing screw for fitting of strip.
56
-
-
... More
M&L for Gl Strip 32mm x 6mm buried in ground for lightening protection all as specified and directed at site
16
-
-
... More
Test point terminal block made of gun metal or phosphorus bronz size 75x75x25mm drilled screwed including 3 nos .8 mm dia 25 mm long hex screw all as specified and directed at site
2
-
-
... More
Material & labour for earthing complete with galvanised mild steel earth plate electrode 600mm x 600mm x6 mm thick buried directly in ground (earth pit not less than 2.5 meter deep below ground level) surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15 cm allaround the plate using GI earth strip 32x6 mm connected to earth plate at one end by means of nut, bolts and washers and connected to metallic bodies of HT/LT equipment as directed GI strip encased in and including GI pipe light grade 50 mm dia with all fittings from upper edges of earth plate to body of equipment fixed with and including 25 x6 mm flat iron clamps, bolts, nuts and washers including providing 40 mm dia GI pipe light grade from earth plate to 300 mm above ground level for watering with 40 mm dia MS dead plug and funnel and wire mesh from earth chamber to upper edge of earth plate, GI funnel with wire mesh fixed on water pipe and PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel TMT bars @ 150 mm both ways center to center with 10 mm dia MS bar in lifting handle, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electrical plate No.3 of SSR Part-I and all as specified and directed.
Note :- On testing after completion of job, if desired earth resistance (i.e. less than one Ohm) is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
2
-
-
... More
Supply & fix aviation obstruction light comprising aluminium housing with poly carbonate enclosure, including its connection, provision of suitable stand made of flat iron for its fixing, grouting and making good distrubed surfaces all as specified and directed. Make Bajaj / cromton / Phlips / Wipro
1
-
-
... More
Supply and fixing of Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLS) cable of size 2.5 sqmm LT, 1100V grade, down through and incl adequate sizes PVC non metallic conduit of 20mm/approprite dia with accessories and fittings and one run of 2.5 sq mm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm/approprite dia shall be measured as one run length, Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. Earth wire shall run inside the conduit pipe (Note :- Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.) Make of Cable- Grandlay/Havells /polycab, Make of PVC conduit - Kalinga/AKG/Polycab
30
-
-
... More
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. MAKE-LEGRAND / SCHNEIDER /HAVELLS
2
-
-
... More
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole & nutral and current carrying capacity SPN 40 to 63 AMP, in the MCB DB complete with connection testing and commissioning. MAKE-LEGRAND / SCHNEIDER /SEIMENS
1
-
-
... More
S&F distribution boards sheet metal, powder coated, DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts 200 amps rated busbar 4 way complete all as specified and directed by Engr-in-charge. MAKE-LEGRAND / SCHNEIDER /SEIMENS
1
-
-
... More
Supply, installation, connecting and testing of ultrasonic based water level indicator suitable for use at water supply installations on overhead reservoirs/underground sumps all as directed at site and consisting of following items :-
(a) Advance process indicator, panel mounting type of size 48 mm x 96 mm, operated on 230 V single phase AC supply, protection class for face plate IP- 65
(i) 4 digit 7 segment LED
(ii) LED status indicator
(iii) TC/RTD/Analog inputs
(vi) Sensor supply
(v) 4 Alarm output
(vii) Max programs -25
(viii) Communication mode - RS 485 mode bus.
(ix) Output for sensor- 24 V DC
Make : Selec, PIC 1000N-D4
(b) ULTRASONIC Water Level Transmitter Compact two wire loop powered which can be configured for either level or distance in meters, feet or a percentage of span, track level changes as fast as 10 meters per minute, suitable for use in corrosive applications incl suitable protection cage and installation on reservoirs overhead/underground having following specifications:-
(i) Measuring Range - 0.3 - 8 m
(ii) Enclosure- IP66 glass filled nylon
(iii) Power supply- 12-30 v dc
(iv) Transducer material- PVDF
(v) Process Connection- 2” BSPT
(vi) Accuracy- +/-0.5% of meas. Value
(vii) Operating temperature- -20 to +70 deg C
Make : Pune Techtrol/Siemens Millitronics
1
-
-
... More
Supply, laying & testing FR PVC insulated, PVC sheathed cable galvanised steel strip or wire armoured, electric control cables (heavy duty) with stranded copper conductor of size 1.5 Sqmm, 2 core, 1100 volts grade connecting with copper lugs fixed with saddle from ultrasonic based water level indicator complete all as specified and directed. Make:- Polycab/Havells/Grandlay (on OHT).
Note :- The cable shall run inside the conduit. The cost of conduit shall be deemed included in the item.
32
-
-
... More
M&L forClamps for holding the CI pipe along the beam/pillar, brackings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint
0.67
-
-
... More
Supply and laying duclite iron pipe with spigot and socket ends including its fittings centrifugally cast, class K-9 in any length laid in trenches 150 mm dia (6") dia complete all as specified and directed at site by Engr-in-Charge.
740
-
-
... More
Supply and laying galvanised pipe "Medium class", including fittings 80 mm (3") dia complete all as specified and directed at site by Engr-in-Charge
600
-
-
... More
Supply and fixing sluice valve of size 150 mm dia, connecting & testing both ends flanged and drilled cast iron body class PN-1 confirming to IS- 14846/2000 complete with gun metal spindle including necessary nut bolt etc for the following sizes (Note :- for these sluice valves which are fixed with pillar of over head tank work involve such as breaking of PCC/Lead flange joints will be deemed to include in the rate quoted & contractor will also repair the damaged floor etc, to match with existing. Make: L&T/Kalpana/Kirloskar
4
-
-
... More
Supply and fixing butterfly valve of size 80 mm dia, connecting & testing both ends flanged and drilled cast iron body class PN-1 confirming to IS- IS 13095 complete with gun metal spindle including necessary nut bolt etc for the following sizes (Note :- for these butterfly valves gaskets and rubber jointing will be deemed to include in the rate quoted & contractor. Make: L&T/Kalpana/Kirloskar
4
-
-
... More
M&L for CI pipe bends, tapers, Tee pieces (Single & double branch) any type and angle /radius and straight connecting pieces but all ends flanged upto 150 bore in mm (for Header) complete all as specified and directed at site by Engr-in-Charge
482
-
-
... More
S & F 150 mm size new heavy duty non return valve, both ends flanged duly drilled, PN-1.00 confirming to IS – 5312 (Make – Kirloskar, Kalpana, BIR) with and including necessary jointing material as required complete all as specified and directed.
2
-
-
... More
Taking up or down (from wall/trenches/floor) existing GI steel tubing and connections, including cleaning for re-fixing or removal of 80mm bore GI pipe complete all as specified and directed at site by Engr-in-Charge:-
600
-
-
... More
All as per item No 63 here-in-before but 50mm bore GI pipe.
360
-
-
... More
Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth for foundation etc or for manholes, laying of pipe in soft / loose soil and getting out complete all as specified
241.2
-
-
... More
Returning filling in, including spreading, leveling watering & well ramming in layers not exc 25cm thick complete all as specified and directed by EIC
201
-
-
... More
Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified & directed
40.2
-
-
... More
S&L XLPE insulated armoured heavy duty electric cable with stranded aluminum conductor 1100 volt grade cross sectional area 16 Sqmm and 2 core all as specified and directed Make:- Polycab / Havells / Grandlay / Gloster
220
-
-
... More
Supply, transporting, erecting steel tubular swaged pole ISI marked, type 410 -SP-31, 9.00 metre long, complete with mild steel base plate, pole cap, finial taper plug, bolts, nuts, washers etc. including painting two coats of aluminium paint over a coat of red oxide primer including 3 Nos. of bands /strips painted with yellow and black colour (300 mm each) in alternate layer from plinth block, marking of pole number with black synthetic enamelled paint 2.5 cm height including one coat of black bitumenous paint on steel surface embedded in concrete foundation complete all as specified and directed.
4
-
-
... More
M&L for street light bracket 1.20 Mtr length, MS Pipe, light grade 40mm with suitable angle of bend, and duly fixed with MS clamp 40 x 5m 02 Nos includung nuts, bolts & washers at the top of the 9.00 meter pole. there should be provision for copper cable run through the pipe for connection to LED security light, the light bracket be painted with two coats of aluminium paint over a coat of red oxide primer, the light bracket should have provison for accomodation of Surge protection devices of s all as specified and directed at site by Engr-in-Charge
4
-
-
... More
M & L for PVC thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 Sqmm 2/4 core and fixed to the Steel tubular poles by means of suitable size of clamps with nuts, bolts and including provn for fixing 01 no of single pole MCBs 6-32 amps,10KA a ‘B’ series = 01 No inside the box complete all as specified and directed. Make :- Sintex/Hensel/standard or equivalent.
4
-
-
... More
Supply and lay cable XLPE Insulated screened PVC bedded galvanized steel strip and wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded alluminium conductor of size 10 Sqmm 2core. Complete all as specified and directed at site.
198
-
-
... More
M&L Tube light grade 40mm bore galvanised iron light grade fixed on poles for cable protection and road/drain crossing. complete all as specified and directed.
20
-
-
... More
M&L earthing complete with galvanised steel earth plate electrode 60x60cm x 6mm thick, bruried directly in ground (earth pit not less than 2.25metres deep below ground level) surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15CM allaround the plate using GI earth earth lead wire 4.0 mm dia connected to earth plate at one end by means of bolts, nuts, check nuts and washers and connected to metallic bodies of LT poles as directed GI earth lead wire be encased in GI pipe of suitable size with all fittings from upper edges of eath plate to body of equipment fixed with clamps, nuts and bolts and washers, including providing 25mm dia GI pipe light grade from eath plate to 300mm above ground leve for watering with suitable dia MS dead plug and funnel and wire mesh from each chamber to upper edge of earth plate, GI funnel with wire mesh fixed on water pipe and PCC 1:2:4, type B-1, duly reinforced with 6mm dia mild steel TMT bars @ 150 mm both ways center to centre with 10mm dia MS bar in lifting handle, excavation, earth work including laying the GI pipe in floor/on pole all as described in electrical plate no.3 of SSR part-I and all as specified and directed at site by Engr-in-Charge.
Note : On testing after completion of Job, if desired earth resistance (i.e less than one Ohm) is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
1
-
-
... More
S&F street light timer panel, three phase with maximum load of 6 Kw with inbuilt astronomical time switch, 32 Amp/TP contactor, 40 Amp SPN confirming to IS/IEC/604947-4-1, FRLSH internal wiring, with IP 54 protection and inbuilt short circuit protection. complete all as specified and directed at site. Make : Havells, HSN Code 8537, Cat Part No IHXSS0106A /CG/Legrand
Note : (i) For fixing on pole, clamps nuts bolts and washers of suitable size be considered in the cost of the work.
(ii) Testing after completion of wk and defect rectification during period of warranty will be get done by the contractor without any extra cost.
1
-
-
... More
Supply & fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact an corrosion resistant including thermal management in multiple optics complete with IP65/66 protection all as specified and directed at site by Engr-in-Charge Havells Cat part No.ENDURACITYLINEARNEOSL70WLED757PASYBOTG or Crompton, model No, Orion Neo, Cat part No. LST-70-CDL-M or Bajaj Model - Edge Nxt, Cat Part No. ENXT P 70L WW CR PC SD.
4
-
-
... More
Excavation in trenches in soft/loose soil exceeding beyond 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface, complete all as specified and directed.
72.23
-
-
... More
Material and labour for clean dry sand in trenches/ducts for cushioning to cable, complete all as specified and directed. (Note. Punned depth of sand shall be measured for payment purpose.)
28.03
-
-
... More
Returning, filling in including spreading, leveling, watering and well ramming excavated hard/soft soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested, complete all as specified and directed.
34.72
-
-
... More
Removing excavated surplus materials obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
37.5
-
-
... More
Material and labour for Brick protection with sub class ‘B’ bricks old size, laid dry, flat over cable, perpendicular across the cable in trenches complete all as specified and as directed.
2.31
-
-
... More
M&L for PCC work type D-2 (1:4:8) with 40mm graded aggregate for foundation to poles / stays/strutus or basements etc complete all as specified and directed.
0.22
-
-
... More
M&L for PCC work type C-2 (1:3:6) with 40mm graded aggregate for foundation to poles / stays/strutus or basements etc complete all as specified and directed.
2.16
-
-
... More
M&L for PCC work type C2(1:3:6) with 20 mm graded aggregate for coping to poles / stays/strutus or basements etc complete all as specified and directed.
0.43
-
-
Evaluation Notes How It Works ?