Military Engineer Services Tender

View complete overview of Uttarakhand MES Tender

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date6 Jan 2025
Closing Date14 Mar 2025
Tender Amount₹ 10,68,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Construction of block of Accn for 16 Nos JCO ( G+3) (RCC Framed Structure) , with permanent specification including plinth protection all as shown on drawings and as specified.

1

-

-

... More
Construction of open shed of One Block of (04 Car ) (RCC Framed Structure) with permanent specification all as shown on drawings and as specified.

1

-

-

... More
Construction of open shed of One Block of (04 Scooters) (RCC Framed Structure) with permanent specification all as shown on drawings and as specified.

1

-

-

... More
SCHEDULE A PART II-A (Internal Water Supply) for details refer Sch A in pdf folder

1

530623

-

... More
SCHEDULE A PART II-B (Internal Water Supply)

-

-

-

... More
S&F health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible tube and ABS wall hook including making connections and fixed in position complete all specified and directed.

60

-

-

... More
S&F CP scatter with CP connecting pipe alongwith all acessaries complete all specified and directed.

16

-

-

... More
S&F Brass Chromium Plated Angle Valve, fancy type screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed.

48

-

-

... More
SCHEDULE A PART III-A (Internal Electrification) for details refer Sch A in pdf folder

1

2859273

-

... More
SCHEDULE A PART III-B (Internal Electrification)

-

-

-

... More
M & L for point wiring using 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade, IS-694 single core multi-stranded (FRLS-H) copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.6 mm thick pressed modular steel terminal box for mounting fittings i.e, modular switch / sockets incl cover plate with frame including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded FRLS-H copper conductor cable as in earth wire and connecting all metal parts to common earth dolly incl cutting and chases pinning in for concealed conduit wiring and making good of disturbed surface complete all as specified and directed for the following: -

-

-

-

... More
Note: (i) Also includes inverter wiring with one run of inverter wire 1.5 sqmm all alongwith circuit also included. (ii) All items used should be ISI marked. (iii) Cutting chases for concealed type point wiring including making good the same with plaster/putty is deemed to be included in quoted rate by the contractor. (iv) Accessories modular metal boxes, cover plate inner & outer is also deemed to be included in quoted rate.

-

-

-

... More
(a) One light point point /bell buzzer/ ceiling fan/Exhaust fan point controlled by one-one way switch.

708

-

-

... More
(b) One three pin 5 Amp socket on same board with other switches.

186

-

-

... More
(c) One three pin 5 Amp socket on independent board

358

-

-

... More
(d) All as per item No 5.01 above but for two way wiring

11

-

-

... More
(e) All as per item No 5.01 above but point wiring with cable 2.50 Sq mm size, with earth continuity conductor of size 2.50 Sq mm.

154

-

-

... More
(e) All as per item No 5.01 above but point wiring with cable 4 Sq mm size, with earth continuity conductor of size 4 Sq mm.

48

-

-

... More
Supply and fixing Vertical Loadline sheet metal enclosure double door, Triple pole and neutral (TP&N vertical loadline) AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 54 & IK 09 protection, with the inbuilt provison for fixing of 1 No MCCB of capacity 100Amps and 12 Nos MCB's inside of DB, with metal door and flush to wall including grouting and cutting in existing wall and making good disturbed surface with two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed.

1

-

-

... More
Supply and fixing Vertical Loadline sheet metal enclosure double door, Triple pole and neutral (TP&N vertical loadline) AC, 415 volts, 08 way, with 200 Amps rated copper bus bar and IP - 54 & IK 09 protection, with the inbuilt provison for fixing of 1 No MCCB 160Amps Capacity and 24 Nos MCB's inside of DB, with metal door and flush to wall including grouting and cutting in existing wall and making good disturbed surface with two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed.

2

-

-

... More
Supply and fixing BLDC Ceiling fan complete with blades, down rods, electronic fan regulator and accessories 230 Volts, 1200 mm sweep, min air delivery 210 CFM five star rated with BLDC motor, super energy efficient, including provision of flexible cable 3 core of suitable size from ceiling rose to fan complete all as specified and directed.

129

-

-

... More
S&F GI pipe medium light grade 15 mm dia laid in trenches/ fixed in walls complete all as specified and directed

45

-

-

... More
SCHEDULE A PART IV (Site Clearance and Earthwork) for details refer pdf folder

1

2550714

-

... More
SCHEDULE A PART V A (Road, Path and Hardatanding) for details refer pdf folder

1

1457063

-

... More
SCHEDULE A PART V B (Road, Path and Hardatanding)

-

-

-

... More
M & L for laying polythene film, transparent of thickness 400 micron over base/floors complete all as specified and directed.

600

-

-

... More
SCHEDULE A PART VI A (Sewage Disposal) for details refer pdf folder

1

250143

-

... More
SCHEDULE A PART VI B (Sewage Disposal)

-

-

-

... More
RCC Septic tank conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 Users

1

-

-

... More
RCC Septic tank conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 Users

1

-

-

... More
M & L for Soakage wells comprising of excavation, in any type of soil, foundation in PCC 1:3:6 type C2 , walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.40 M dia X 3.0 M effective depth all as specified and shown in drawing TD-309, sheet No 1/4 to 4/4

2

-

-

... More
M & L for Soakage wells comprising of excavation, in any type of soil, foundation in PCC 1:3:6 type C2 , walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.0 M dia X 3.0 M effective depth all as specified and shown in drawing TD-309, sheet No 1/4 to 4/4

2

-

-

... More
SCHEDULE A PART VII (Area Drainage) for details refer pdf folder

1

747619

-

... More
SCHEDULE A PART VIII (Protective Work / Retaining Wall) for details refer pdf folder

1

3592545

-

... More
SCHEDULE A PART IX A (Hot Water Supply) for details refer pdf folder

1

481417

-

... More
SCHEDULE A PART X A (External Water Supply) for details refer pdf folder

1

217178

-

... More
SCHEDULE A PART X B (External Water Supply)

-

-

-

... More
Supply and fixing openwell monoblock pumpset 3 HP capacity model no KOS-335+* (1xrunning and 1 x standby) at rated voltage 50hz, three phase AC power supply, insulation -B class, protection IP68, voltage range 200 to 440 volts.

2

-

-

... More
Supply and fixing MK1 DOL Starters 4HP capacity (HSN Code 8536) suitable for pump/motor 3 phase, 415V 50HZ with relay range 4-6.5, coil voltage-SS96210SOTO. complete all as specified and directed

2

-

-

... More
M&L in replacement of service cable of size 6 sqmm 3 core for Submirsable Motor pump of capacity 5 to 10 HP complete all as specified and directed

24

-

-

... More
SCHEDULE A PART XI A (EXTERNAL ELECTRIC SUPPLY) for details refer pdf folder

1

445197

-

... More
SCHEDULE A PART XI B (EXTERNAL ELECTRIC SUPPLY)

-

-

-

... More
Supply, installation commissioning and testing of 160 KVA transformer,step-down 11/0.433 KVA, outdoor type, vector group DY-11, powder coated, copper Wound,3 phase,4 star rating wire 50 cycles per second,oil immersed naturally cooled with external cooling tubes,core type delta connected on primary (HT Side) and star connected on secondary (LT Side) having tapping -7.5%, -5%, -2.5%, 0%, +2.5%, +5%, +7.5% to be changed by means of hand including first filling of oil of dielectric strength not less than 40 KV,

1

-

-

... More
the max temperature rise should not exceed 45 degree centigrade in oil and 50 degree cntigrade in HV/LV winding when measured by the resistance method after continous full load run in ambient temperature the transformer shall confirming to IS-1180/2014 (level-I) all standard operating complete with standard fittings and accessories such as breather unit , drain out valve,roller,conservator oil tank of suitable capacity with level indicator , exhaust vent ,temperature gauge,pressure gauge etc and mounting complete all as specified.

-

-

-

... More
Construction of platform of size 2.1m x 2.1m x 1.2m (clear height with additional 150mm thick PCC 1:3:6 type C-2 foundation below ground level), made out of 23cm brick masonry in cement mortar 1:6, (below ground level, hollow space to be filled hardcore of size n.exc 63 mm, deposited, spread and levelled in layers not exceeding 15cm thickness, watered and well rammed) with a 100 mm thick re-inforcement cement concrete 1:2:4 type B-2, 8 mm dia MS bar as in floor of platform, plastering in CM 1:4, including stair for platform as per site requirement and protection with XPM,

1

-

-

... More
angle iron gate of size 40x40x5 mm and chain link fencing rail around the platform with angle iron frame upto 1.20m clear height, supports grouted in PCC 1:2:4 type B-1 foundation complete all as specified and directed.

-

-

-

... More
Cable joining kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3 core AB cable of size 50 sqmm to 95 sqmm all as specified and directed.

2

-

-

... More
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and includingGI Strip of size 32x6mm and light grade protection pipe of 40 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM,

16

-

-

... More
excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value complete all as specified and directed. (GI strip upto 7.5m including testing consider in this item). ( 06 for this schedule & 10 for Lightening Protection Schedule )

-

-

-

... More
Design, Supply, Installation,Testing and commissioning of LT weather proof panel (1200mmx1200mmx500mm)board outdoor type powder coated outdoor type double door shutter, made out of CRCA 3.15 mm thick outer and 2 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outoor, floor mounting type with closed bus bar , chamber and with Aluminium bus bar 300 amps with necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supply as per CPRI approved required, indicator lamps R-Y-B,selector switches and internal wiring including making PCC foundation type 0.6 Mtr above ground level and 0.3 mtr below ground level

2

-

-

... More
grouting etc all as specified and directed with the following Work also includes provision of suitable size of cable glands,cable lugs,nut, bolts,washers etcThe bottom portion of enclosure shall be minimum 0.6 mtr above ground level and 0.3 mtr below ground level of legs of angle iron ). Totally Type tested Panel as per the latest standard IEC 61439. The panel should have Busbar clearance of 25 mm for Ph to Ph and 19 mm for Ph to neutral, Zero Stray voltage doors and panels, polyster glass support for insulation. The cable alleys should be 300 mm wide and it should be fitted with hinged door that open up to and angle of 95 Deg. The provision of cable entry should be from Bottom.

-

-

-

... More
The IP protection of panel should be IP-42 for external and IP2X for internal with 3B as Form of sepration. Panel should be suitable for sesmic zone V. The panel should be equiped with suitable size of CT and display meter for VAF measurement.

-

-

-

... More
(a) Aluminium bus bar capacity 300 Amps for Phase-R-Y-B-3 Nos & 250 Amps for neutral -1 No (b) MCCB FP 36 KA 160 Amps- 1 Nos(I/C) (c) MCCB FP 16 KA 100 Amp - 02 Nos (Outgoing) (d) MCB DP 16 KA 63 Amps - 01 Nos (outgoing) (e) Digital Ammeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No and suitable CT ratio 0-300 Amps

-

-

-

... More
(f) Digital Voltmeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No 0-500 V (g) complete control panel wiring with stranded copper conductor of suitable size along with one set indicator lamp for R,Y & B for each incoming and outgoing feeder

-

-

-

... More
Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-31 (9.00 meters long) with cast iron base frame, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection , including writing of pole number complete all as specified and directed by the Engr-in-Charge. Note: (1) All excavation & earth work as involved shall be measured & paid seprately. (2) PCC foundation and Coping as involved shall be measured and paid seprately under respective items.

9

-

-

... More
Supply and fix in replacement of bracket made out of GI tubing single piece not wleded bended at proper angle of size 40mm dia,light grade 1.5 mtr long including painting with aluminium paint over one coat of red oxide to the bracket etc complete.including 1.0 sqmm 3.0 core flexible Copper cable in PVC conduit with clamp from juction box to connecter of street light fitting.

9

-

-

... More
Supply and fixing in replacement LED flood light 60 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.

9

-

-

... More
Supply and fix pole box size 450 x 300 x 200 mm fabricated out of 2 mm thick MS Sheet having 4 Nos aluminium busbar of suitable size with 1 No. MCB SP 6 Amps front openable hinged cover outdoor type weather proof suitable for mounting on steel pole including fixing MS clamp 02 Nos with nuts, bolts and washers complete all as specified and directed.

9

-

-

... More
SCHEDULE A PART XII A (LIGHTENING PROTECTION) for details refer pdf folder

1

20221

-

... More
SCHEDULE A PART XII B (LIGHTENING PROTECTION)

-

-

-

... More
Supply and fix wooden block heavy weight of size (25 x 3.15) mm with hole of 20 cm for fixing of air termination rod of any size complete all as specified and directed.

20

-

-

... More
SCHEDULE A PART XIII (DEMOLITION) for details refer pdf folder

1

289866

-

... More
Note : Tenderers may note that amount of credit Rs 3,21,517.64 will be deducted from the total amount arrived, at the time of Acceptance of contract.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.