Military Engineer Services Tender
View complete overview of Uttarakhand MES Tender
Military Engineer Services - MES Tender
Civil And Construction
Pipe Line Project
Eprocure
Opening Date8 Nov 2024
Closing Soon29 Nov 2024
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_683107_1Tender No
GE /CLT / of 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR/MAINT OF INTERNAL WIRING AND REPLACEMENT OF OLD U/S FITTING IN ZONE - I AREA AT CLEMENT TOWN
REPAIR/MAINT OF INTERNAL WIRING AND REPLACEMENT OF OLD U/S FITTING IN ZONE - I AREA AT CLEMENT TOWN
REPAIR/MAINT OF INTERNAL WIRING AND REPLACEMENT OF OLD U/S FITTING IN ZONE - I AREA AT CLEMENT TOWN
BOQ Items
Dismantling and taking down old damaged existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified
73
-
-
Taking down old serviceable meter of any size & any type from wall by disconnecting all electrical connections and refixing the same complete all as specified & directed by Engineer-in-Charge.
10
-
-
Fixing only serviciable light fitting received against item No 01 above, complete all as specified & as directed.
80
-
-
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit MMS ,duly concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates
220
-
-
All as per item No-07 but One 3pin/5pin 5/6 Amps socket out let on same board with other switches , with cables 1.5 sq mm size , complete all as specified and directed.
50
-
-
All as per item No-07 but One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed .
50
-
-
All as per item No 7 above but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point.
60
-
-
All as per item No 7 above but in existing concealed conduit complete all as specified.
200
-
-
All as per item No 8 above but in existing concealed conduit complete all as specified.
50
-
-
All as per item No 9 above but in existing concealed conduit complete all as specified.
50
-
-
All as per item No 10 above but in existing concealed conduit complete all as specified.
50
-
-
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including PVC conduit MMS ,duly surface to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates
850
-
-
All as per item No 15 above but One 3pin/5pin 5/6 Amps socket out let on same board with other switches , with cables 1.5 sq mm size , complete all as specified and directed.
170
-
-
All as per item No 15 above but One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed .
250
-
-
All as per item No 15 above but above but controlled by two, two way piano switch 5/6 Amps.
2
-
-
All as per item No 16 above but with 2.5 Sqmm PVC insulated FRLS cable for 15 Amps power point.
165
-
-
Supply and fixing switch modular single pole,, one-way 6Amps, 1 module 240 Volts AC all as specified and directed by Engr-in-charge .
1590
-
-
Supply and fixing switch modular single pole,, one-way 16 Amps, 1 module 240 Volts AC all as specified and directed by Engr-in-charge .
275
-
-
Supply and fixing modular socket, 6A -2/3/5 pin combined 2 module ISI marked 230 volts, 50Hs complete all as specified by Engr-in-charge .
620
-
-
Supply and fixing modular socket, 6A/16A-5/6 pin combined 2 module ISI marked 230 volts, 50Hs complete all as specified and directed by Engr-in-charge .
275
-
-
Supply and fixing Modular bell push single pole one way 6 Amps, 1 module all as specified & directed by Engr-in-charge .
25
-
-
Supply and fixing step socket type modular fan regulator 240 V , 100Watt 2 module complete all as specified.
140
-
-
Supply and fixing switch piano flush type single pole, one-way 5/6 Amps, 240 Volts AC
50
-
-
Supply and fixing switch piano flush single pole, one-way 16 Amp, 240 Volts AC
50
-
-
Supply and fixing socket out let 5 pin 6 Amps flush type all as specified.
50
-
-
Supply and fixing socket out let 5/6pin 5 Amp and 15 Amp flush type (multi) suitable for 240 Volt AC all as specified.
50
-
-
Supply and fixing bell push piano flush type single pole one way 6 Amps all as specified.
20
-
-
Supply and fixing switch piano flush type single pole, two way 6 Amp, all as specified
10
-
-
Supply and fixing stepped type electronic fan regulator flush type on the existing phenolic laminated sheet, socket type, comlpete all as specified & as directed.
40
-
-
Supply and fixing ceiling rose surface bakelite 65x25mm dia having three terminals all as specified
260
-
-
Supply and fixing batton/angle holder insulated body with back plate, suitable for batten fittings all as specified & directed.
20
-
-
Supply and fixing in repair switch piano flush type single pole, one-way 5/6 Amps, 240 Volts AC complete all as specified.
50
-
-
Supply and fixing in repair switch piano flush single pole, one-way 15/16 Amp, 240 Volts AC complete all as specified.
40
-
-
Supply and fixing in repair socket out let 3/5 pin 5/6 Amps flush type complete all as specified.
40
-
-
Supply and fixing in repair socket out let 5/6pin 5 Amp and 15 Amp flush type (multi) suitable for 240 Volt AC complete all as specified.
40
-
-
Supply and fixing in repair batton/angle holder insulated body with back plate, suitable for batten fittings all as specified & directed.
20
-
-
Supply and fixing in repair bell ding dong AC 230/240 Volts single pole
30
-
-
Supply and fixing in repair step switch type fan regulator 120/280 V all as specified.
30
-
-
Supply and fixing in repair switch modular single pole,, one-way 6Amps, 1 module 240 Volts AC all as specified and directed by Engr-in-charge .
40
-
-
Supply and fixing in repair switch modular single pole,, one-way 16 Amps, 1 module 240 Volts AC all as specified and directed by Engr-in-charge .
20
-
-
Supply and fixing in repair modular socket, 6A -2/3 pin combined 2 module ISI marked 230 volts, 50Hs complete all as specified by Engr-in-charge .
20
-
-
Supply and fixing in repair modular socket, 6A/16A-5/6 pin combined 2 module ISI marked 230 volts, 50Hs complete all as specified and directed by Engr-in-charge .
20
-
-
Supply and fixing in repair step socket type modular fan regulator 120/280 V , 100Watt 2 module complete all as specified.
10
-
-
Supply and fixing in repair Modular bell push single pole one way 6 Amps, 1 module all as specified & directed by Engr-in-charge .
5
-
-
S&F of decorative box type 20 -22watt LED fittings with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed.
800
-
-
S&F of 10 watt LED light fitting mirror type with high out put diffuser 2 feet, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size other fixing accessories complete all as specified and directed.
30
-
-
S& F in repair oval shape Bulk head Edge-lit LED fitting comprising with high brightness LED 10 watt, IP-67 protection complete all as specified and directed.
20
-
-
Supply and fixing in repair round shape 6 watt 220 volts AC surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
20
-
-
Supply and fixing in repair round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
20
-
-
Supply and fixing in repair round shape 12 watt 220 volts AC surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
50
-
-
S& F Glaze in repair Wall Light including 9/10 watt LED lamp ( B22), 6500 K , complete all as specified and directed.
50
-
-
S & F in repair LED building security light 25 watts LED including fixing arrangements with suitable size bracket, size not less than 0.9 mtrs long & 32 mm dia complete all as specified and directed.
12
-
-
S & F in repair LED building security light 45 watts with inbuilt daylight sensor which swiches ON/OFF automaically in the absence/presence of sunlight. IP-66, IK08 pressure die cast fabricated aluminium housing with epoxy powder coated finish complete with suitable size bracket complete all as specified and directed.
10
-
-
Supply and fixing in repair LED luminaire 600mm X 600mm, 35/36 watt, 220V AC Recessed type with high efficiency PMMA diffuser soft glair free light complete with accessries suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
70
-
-
Supply and fixing in repair LED luminaire 600mm X 600mm, 35/36 watt, 220V AC surface type, 6500K with high efficiency PMMA diffuser soft glair free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
20
-
-
Supply and fixing in repair LED Recessed Spot light 30 watt , model No CDR-214-30-30-SL-NWH forcommercial use long lift with 30000 burning hours with CRI80, 30 watt, 3000K,CCT, Beam angle 36 degree vertical tilt 300 of dia 140 mm.
15
-
-
Supply and fixing in repair LED Recessed Spot light 45/50 watt , at a height of 20 meter from ground level on false ceiling by making all safety arrangement and T & P, model No CDR-215-50-40-SL-NWH for commercial use long lift with 30000 burning hours with CRI- Ra70, 12 watt, 4000K,, Beam.
15
-
-
Supply and fixing in repair Gate / picture light LED Spot light 12 watt , model No/ Item No-675 BWL, voltage AC85-240V,50Hz for commercial use with 30000 burning hours with CRI80, 40/50 watt, 3000K,CCT, Beam angle 36 degree vertical tilt 300 of dia 160 mm.
10
-
-
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 8 way with 200 Amps rated bus bar all as specified and directed .
48
-
-
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 4 way with 200 Amps rated bus bar. all as specified and directed .
5
-
-
Supply and fixing sheet metal enclosure double door type for MCBs DB TPN 415V AC 4 way with 200 Amps rated bus bar. all as specified and directed .
4
-
-
S & F vertical load line in sheet metal enclosures MCCB TPN DB's with double door for incorporating MCCB as incomer and MCBs SP/SPN as outgooing , IP-43 , TPN 4 way with 200 amps rated busbar, 440 volts, as per IS-8623 including taking out old UNSV DB and making good the disturbed surface of wall and match with the existing surface compelte all as specified and as directed. (Note- MCCB 3 pole 63 amps as main incomer will be included in quoted rate)
14
-
-
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 12 way with 200 Amps rated bus bar all as specified and directed .
2
-
-
Supply and fixing MCB SPN 40 Amp 240 V AC 10 KA repturing capacity all as specified.
60
-
-
Supply and fixing MCB 5 to 30 Amp 'B' series 10 KA repturing capacity complete all as specified.
350
-
-
Supply and fixing MCB isolator 4 pole 63 Amps 240 V 10 KA repturing capacity all as specified.
4
-
-
Supply and fixing single pole and neutral enclosure with a two pole and earth plug socket complete with one, single pole MCB 20 Amps 10 KA repturing capacity 240 Volts AC all as specified.
12
-
-
Supply and fixing single pole and neutral enclosure modular type with a two pole and earth plug socket complete with one, single pole MCB 20 Amps 10 KA repturing capacity 240 Volts AC all as specified.
4
-
-
Taking down old u/s cable & Supply and laying or fixing or passing through pipe, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade , cross - sectional area of 16 sqmm 4 core complete all as specified & as directed.
600
-
-
Taking down old u/s cable & Supply and laying or fixing or passing through pipe, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade , cross - sectional area of 25 sqmm 4 core complete all as specified & as directed.
400
-
-
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out cables, pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge.
130
-
-
M & L for fine dry sand cushioning for underground cable by providing layers of sand 8 cm before laying and 15 cm deep after laying the cable including streching the cable ( measurement to be taken after punning down consolidated thick ness ). complete all as specified and as directed .
45
-
-
Supply and laying , un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250mmX 150mmX40mm with breaking load capacity 200 KG complete all as specified & as directed.
4000
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge.
60
-
-
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engr - in - Charge.
55
-
-
Supply and fixing sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable (FRLSH) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/concealed in wall as per existing along with 6.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion all as specified and directed
400
-
-
Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable (FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/ concealed in wall as per existing along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion all as specified and as directed Note:Two runs of phase , neutral wire and one run of earth wire will be measured as one RM or one length.
1100
-
-
Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable (FRLSH)1100Volts grade in existing conduit along with 4.0 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH)as earth wire and wire connected with main earth dolly including making good surfaces all as specified and directed Note:Two runs of phase , neutral wire and one run of earth wire will be measured as one RM or one length.
190
-
-
Supply, fixing, installation and testing of LT-CT operated multifuction DLMS compliance energy meter of accuracy class 0.5, 3 X 240V, 50 Hz, with optical & RS232 port, backlit LCD display, measures & display trivector energy, load survey, TOD, Tamper detection * logging, power On/Off events, instataneous parameters of rating 200/5 or 100/5 (As per site requirement) with display in absence of power complete in poly carbonate body in class 1/0.5 accuracy as per IS-13779 complete including taking down old type KWH meter with disconnection of incoming and outgoing electric supply all as specified and directed. (Note- (i) Rates quoted is deemed to be included for necessary incoming and out going electrcial connection and fixing at any directed location as per the EIC).
(ii) Old KWH meter will be deposited to MES store.
8
-
-
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level connected by 4 mm GI wire as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM and charcoal, dust and common salt all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.
(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
5
-
-
NOTES :-
1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%