Military Engineer Services Tender

View complete overview of Uttarakhand MES Tender

Military Engineer Services - MES Tender

Works
Civil And Construction
Eprocure
Opening Date10 Jun 2024
Closing Date24 Sep 2024
Tender Amount₹ 14,01,82,312 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No 3 here in before but for RCC Lift Well and Chamber 3.00 meter inner dia and 7.92 Meter over all dept complete all as specified and shown on drawings.

2

-

-

... More
All as per item No 3 here in before but for RCC Lift Well and Chamber 3.00 meter inner dia and 7.77 Meter over all dept complete all as specified and shown on drawings.

1

-

-

... More
All as per item No 3 here in before but for RCC Lift Well and Chamber 3.00 meter inner dia and 6.94 Meter over all dept complete all as specified and shown on drawings.

1

-

-

... More
All as per item No 3 here in before but for RCC Lift Well and Chamber 3.00 meter inner dia and 5.80 Meter over all dept complete all as specified and shown on drawings.

1

-

-

... More
All as per item No 3 here in before but for RCC Lift Well and Chamber 3.00 meter inner dia and 5.90 Meter over all dept complete all as specified and shown on drawings.

1

-

-

... More
All as per item No 3 here in before but for RCC Lift Well and Chamber 3.00 meter inner dia and 6.50 Meter over all dept complete all as specified and shown on drawings.

1

-

-

... More
All as per item No 3 here in before but for RCC Lift Well and Chamber 3.00 meter inner dia and 7.22 Meter over all dept complete all as specified and shown on drawings.

1

-

-

... More
All as per item No 3 here in before but for RCC Lift Well and Chamber 3.00 meter inner dia and 7.76 Meter over all dept complete all as specified and shown on drawings.

1

-

-

... More
All as per item No 3 here in before but for RCC Lift Well and Chamber 3.00 meter inner dia and 6.2 Meter over all dept complete all as specified and shown on drawings.

1

-

-

... More
All as per item No 3 here in before but for RCC Lift Well and Chamber 3.00 meter inner dia and 7.0 Meter over all dept complete all as specified and shown on drawings.

1

-

-

... More
Design (Hydraulically Tructurally & Aesthetically), supply, install, erect, connect, test and commissioning and giving satisfactory trials of sewage treatment plant based on the principles of Aerobic attatched growth non clogging randomly Moving Bed Bio Reactor (MBBR) having capacity of 1.2 MLD for treating domestic effluent from toilets, bathrooms and kitchen waste etc received at an invert level all as specified as per drawing of STP, having raw sewage and treated water characterstics as mentioned in PS, consisting 3 times average flow as peak flow with preliminary, secondary and tertiary treatment with all electro mechnical equipments, accessories, all associated civil works, safety equipments, tools, plants and manning for two years of day to day operation and maintenance, Administrative block/laboratory with testing apparatus to test the parameters of various stages of process as per manual of sewage and sewage treatment of CPHEEO, etc complete of function as single, compact and self sustaining type, unit with minimum moving/mechanical equipment from the intake of Effluent to outlet upto treated water comprising of SS fine screen, Receiving chamber, Screen Chamber, collecting tank (Wet Sump), dry Sump, sewage equalisation tank, receiving chamber, grit channel, Anoxic chamber, Raw Sewage pump, MBBR Tanks, Media, Air blowers and Air grid system with air blower room, secondary tube settler, sludge sump, filter press, Sludge drying beds, Hypo dosing system, chlorine dozing appratus, chlorine contact tank, filter feed tank, pressure sand filter, activated carbon filter, treated effluent sump, open drain,

1

-

-

... More
piping, interconnections, valves, Electrical Panel, cables, earthing, inspection platform,ladder,railing, footpath, plinth protection,over flow pipe, cover/grading, etc. within the installation with all measuring instruments, complete all as specified and as given below and all as per technical data sheet attatched as Annexure 'A' to particular specification :- (A) Electro Mechnical Items (i) RAW SEWAGE TRANSFER PUMPS Three Nos (Two working and one standby) fully submersible, centrifugal non-clog sewage handling type pump suitable for solid handling of atleast 20 mm dia for raw sewage transfer from collecting tk to equalization tank of capacity : Minimum 50.00 m3/hr and head not less than 15 Meter and Three Nos(two working and one standby) fully submersible, centrifugal non-clog sewage handling type pump suitable for solid handling of atleast 20 mm dia for raw sewage transfer from equalization tk to receivig chamber of capacity : Minimum 425LPM and head not less than 15 Meter The pump shall have complete CI construction, TEFC induction motor of suitable capacity to run on 400/440V, 3 phase, 50 Hz cycles A/C power supply with single phase preventor, dry run protection etc. including pressure gauge, lifting arrangement for the pump with provision of guide ropes/ rail to guide submersible pump from

-

-

-

... More
upper level to operational level in sump basin with suitable channels/angle section and pipeline made of SS-304, valves, level controller electronic type with stainless steel probes/sensors and float switches for automatic operation with pump logic for operation according to flow of sewage, cable, starters,single phase preventer panel, indicators, selector switches, pressure gauges, earthing etc. complete with other accessories as required. (ii) AIR GRID AERATION SYSTEM One set of Header and lateral type coarse air grid system of externally controlled with individual down comer line type complete with valves and air distribution grid complete max pressure 6.25 kg/cm2, with pipe line made of SS 304 where ever submerged or else MS class B epoxy painted with all fittings such as tees, crosses, plugs, sockets, elbows, reducers, supporters and clamps, puddle flange, nylon rope braided hose with all accessories to make it retrievable etc with non clog type air dispersion system capable of handling of air with oxygen transfer with efficiency of 3-4% per meter water depth, all as required for equalization tank, MBBR . (iii) AIR BLOWER Two Nos (One working and one stand by) Air Blower twin-type blower (twin lobe root type) with motors/pulleys of capacity 500 m3/ltr, head 6250 mm minimum WC driven through 'V' belt or directly coupled through flexible coupling to a TEFC motor of suitable capacity suitable for 400/440 volts, 3 phase, 50 cycles

-

-

-

... More
AC supply with single phase preventer, starters including rigid one piece CI casing and side plates, anti friction bearings, suction silencer, discharge silencer, anti vibration pads necessary foundation, common base plate, lubricant oil, etc. complete with valves, NRV, rubber flexible complete all as recommended by OEM. (iv) CHLORINE DOSING SYSTEM One set of Hypo-chlorine solution dozer comprising of 100 Ltrs Cap. HDPE (Chemical grade) tank with inlet/outlet connection of inlet size 10 mm dia along with 01 No. electronic metering pump of adjustable capacity for dosing of chlorine solution (0-4 LPH) with testing and commissioning complete. (v) BAR SCREEN 2 Nos stainless steel bar screen suitable for minimum chamber size as per annexure 'A' to PS comprising of fine screen with suitable lifting arrangement. The fine screen bars shall be of 25 x 5 mm size with 6 mm clear opening and inclined at 45̊ , GI hand rack, bar rack to be provided of SS 304 bars to cover the width of screen chamber with a racking arm for manual operation. (vi) FLOW METER TOTALIZER : One online electromagnetic water flow meter of suitable dia with totalizer meter, aluminium housing, with Elastomer liner, in treated water line with all accessories complete conforming to environmental protection IP 68/NEMA6/4. End connection should be made of ANSI 150, Electrode material of 316 SS, Metering tube made of SS, output - Analog 4-20 mA, fully isolated, 2 line LCD display, Glass loaded polycarbonate enclosure and polycarbonate window, accuracy - 0.2% suitable for operation on 85 - 265 V AC, working temperature 10- 600°C of flow 0-50 m3/hr complete incl, testing and commissioning all as specified and directed.

-

-

-

... More
(vii) PRESSURE GAUGE One lot of stainless steel round dial Pressure gauge of 0-7 kg/cm2 for pumps & 0-1.0 kg/ cm2 pressure having 100 mm dia dial size with suitable valve for on/off of min 15 mm dia for measuring pressure at every required points such as pumps, filters, air lines etc. complete. (viii) MBBR : 02 nos MBBR tank of suitable size as per annexure 'A' made of RCC M 30 with plinth protection, railing, ladder, working platform, rungs etc complete, all as per standard engineering practice of shape and dimension as per OEM with min 0.5 mtr free board with media floating type PP (polypropylene) material and shape as per OEM having specific density 0.97 g/cc with necessary SS raiser pipe mesh, MS epoxy coated mesh box for retaining the media within the tank. (ix) TUBE SETTLER 01 no tube setller tank made of RCC M30 with plinth protection, working platform, railing, ladder, rungs, etc complete, all as per standard engineering practice and annexure 'A' with all internal tube settler media hexagonal PVC sheets minimum 2.2 cum with tongue and groove arrangement type, plain settling area at 55 deg angle with : min 7 Sqm/cum surface area. (x) SLUDGE DRYING BED : 02 nos sludge drying beds in brick masonry construction of given size and shape capable to air dry/sun dry the digested sludge coming out from tube settler tank with in a given time period cycle as per design. The sludge drying bed shall be provided with PCC channel, filter media comprising of coarse sand under laid by layers of graded gravel, central bed drain/ under drain for collection of filtrate and necessary pipe work for carrying the filtrate to equalization tank.

-

-

-

... More
(xi) MISC ITEMS : (a) VALVES One lot of valves such as gate valves/butterfly valves/Sluice valve/NRV/Air Release valves of suitable size as required. (b) PIPES : All inter-connection piping between Pumps, tanks, filters etc. all as required with stainless steel SS 304 wherever submerged and with MSEP for non submerged pipes as per colour code marked direction of flow and type of sewer within battery limit including tees, bends, flanges, nut bolt, gasket, etc. including necessary primary and secondary supports with masonry work/structural steel work all as required and as specified. (B) MISCELLANEOUS ITEMS (i) One display board of schematic diagram showing flow chart and P&L diagram of the sewage treatment plant drawn on Acrylic white sheet with cloured paints duly marking the details and duly fabricated with suitable aluminium frame of suitable size not less than 1 x 1.5 m. (ii) Supply and fixing glow sign board of size 3000 x 800 x 150 mm, weather proof made of MS angle 50 x 50 x 6 mm with white acrylic sheet 2 mm thick and writing as directed by engineer-in-charge with arial black font of suitable size not exceeding 150 mm but not less than 100 mm and provision of 4 nos tube light 1 x 18W LED type with other accessories and grouting on floor/wall/roof of plant room with suitable primary and secondary supports. (iii) Supply and fix fire point comprising of water (stored presure) fire extinguisher (IS:6234) 9 ltrs capacity - 02 nos, Dry chemical powder ABC type of 4.5 Kg capacity- 02 nos, Light weight squeeze grip type CO2 extinguisher (IS:2878) 3 Kg capacity - 02 nos.

-

-

-

... More
(D) CIVIL COMPONENTS (i) Construction of sewage treatment plant comprising of SS fine screen,Receiving chamber, Screen Chamber, collectig tank(wet sump), dry sump, Sewage equalisation tank,receiving chamber,grit channel,Anoxic chamber, Raw sewage pump, MBBR Tanks, Media, Air blowers and air grid system with air blower room, secondary tube settler, sludge sump,filter press,Sludge drying beds, Hypo dosing system, chlorine dozing apparatus, chlorine contact tank, filter feed tank, pressure sand filter,activated carbon filter,treated effluent sump, and Open Drain etc complete all as per annx 'A' and all as shown in the flow diagram and as directed by Engr-in-Charge. (ii) All associated civil works for STP such as foundation of pumps, base frame, drains, foot path, ladder, inspection platform, plinth protection, railing around open tanks etc. as required for Electro Mechanical and civil items shall be provided. All raised (above GL) open tanks/structure shall be cordoned off with suitable railing made of MS pipe of 25 mm dia of class 'B' pipe to height of not less than 90 cm painted with two coats of enamel paint over one coat epoxy. All open tanks/ structures at GL are to be provided with epoxy coated MS wire mesh of suitable size and grid not more than 60 x 60 mm duly painted with two coats of enamel paint. MS epoxy coated rungs of suitable size and shape, to access the bar screen pit, oil and grease trap for collection of screening shall be provided. PCC foot path along the sump to a minimum of 1m width will be provided. (iii) Any other minor civil work required for erection and smooth functioning of sewage treatment plant such as :- (a) Foundation for pumping sets, air blower, sewage pipe line, air lines as per manufacturer design complete. (b) Excavation for pipe line work, cable work foundation supports etc.

-

-

-

... More
( c) All mild steel work in rolled steel section MS plates, flat round bolts and nuts etc in necessary structural steel work for supporting /jointing/ fastening sewage water pipes, air lines, drain water pipes etc. (d) painting of two coats of synthetic enameled paint over one coat of red oxide primer of all mild steel pipe/structure as per the standard colour coding of the sewage treatment plant. (e) Painting over on pipe line showing arrow/indicator for flow of sewage water/sludge with distinguished colour and stenciling of major components/for identification and full proof operation of switch gears/indicators. (f) Suitable open drain of PCC considering velocity of not more than 0.8 m/sec for connecting the back wash/overflow/drain from various tanks to the drain sump. The drain shall be covered with suitable MS gratings made of suitable angles/flats and frame made of MS angle iron of suitable size. The drain cover shall be in flush with the top surface of the drain. NOTES 1 1) The tenderer shall be responsible for the sewage treatment plant to provide the treated water characteristics as mentioned in PS irrespective of the qty of effluent flow to STP in the schedule and parameters of inlet Raw sewage given in PS. 2) The tenderer should get the plant installed by any one of the original manufacturer with make mentioned in Appx 'A'. For items in respects where no makes are specified, the recommendation of OEM shall be followed. 3) The technical specifications and capacity of various items in the schedule are given on not less than basis. In case of any change considered necessary in the technical specifications/capacity of any items given in the schedule to achieve the parameters given in PS, the tenderer should furnish the same 15 days prior to receipt of the tender duly justified with their detailed designe calculations.

-

-

-

... More
4) In the event of non submission of revised specifications/capacity as brought out under note (3) above, and in case of any change considered required in the technical specification/plant capacity of any item during execution stage, the contractor shall provide the same without any cost. The rates quoted by the contractor shall be deemed to have been included for all such changes, which are essential to provide satisfactory performance/functioning of the plant. 5) The contractor shall intimate the name of OEM and submit a certificate from the OEM confirming that the entire plant shall be got executed by them with make as listed in Appx 'A' to tender through them/their accredited agencies before commencement of work. 6) Structural drawings of all RCC structres (civil work) required to be constructed in the subject work shall be prepared by the contractor based on soil bearing capacity at the site of work and shall be submitted alongwith soil investigation report duly vetted by IIT/NIIT/Govt. Engg. College within one month of acceptance of tender. All civil structures shall be constructed as per specifications given in the tender documents, the same shall be as per OEM specifications and as per standard codes. Tenderer shall visit the site of work and ascertain the soil bearing capacity by making soil investigation. Lump sum quoted in respect of Schedule 'A' Part IB shall be deemed to have included the cost of above. 7) Civil works like foundation for pumps, ladders for sumps, railing, flooring, plastering etc shall be as per standard engineering practice. 8) All RCC work shall be done with M-30 design mix concrete all as per IS-456 of 200. 9) Any item not covered in scope but required for completion as per standard engineering practice and smooth functioning of STP shall be provided as per OEM and the same shall be deemed to have been included in quoted rates.

-

-

-

... More
10) Tenderer shall visit the site and prepare a layout of STP showing all the civil components, plant room, foot path, railing, ladder (external), platform, plinth protection, open drains, over flow pipe, fencing gate etc and get it approved by the accepting officer before commencement of the work duly recommended by GE. 2. Operation and maintenance of sewage treatment plant 1.2 MLD MBBR Type for continuous service by providing 1 skilled and 1 unskilled operators in 2 shifts (starting from 0400Hrs to 1000Hrs & 1200Hrs to 2000Hrs) of 8 hours each from the date of commissioning of STP for 2 years including routine, preventive and breakdown maintenance of plant. All spares/ replacement of equipments/any worn out items, if any will be provided by the tenderer at his own cost including all consumables like liquid chlorine, lubricants, oil, grease, bearings, cotton waste etc during the period including disposal off of sludges periodically obtained from sewage treatment to out side of defence land through covered vehicle complete all as specified and directed by Engineer-in-Charge. Note: (i) The sludges/cake (manure) obtained from the sewage treatment plant shall be the property of the tenderer and the same shll be disposed off periodically during the manning and operation of plant. The rates quoted by the tenderer are deemed to have taken into consideration of the above aspect. (ii) Testing of treatment sewage for the treated water characteristics given in the tender shall be got done by the contractor from any Govt. Approved lab or lab approved by GE on quartarly basis during the manning and operation period and the test report shall be submitted to GE. Contractor's quoted rate shall be deemed to have included the same. (iii) The period of comprehensive maintenance of STP will commence from one year after the date of completion.

-

-

-

... More
Design (Hydraulically Structurally & Aesthetically), supply, install, erect, connect, test and commissioning and giving satisfactory trials of sewage treatment plant based on the principles of Aerobic attatched growth non clogging randomly Moving Bed Bio Reactor (MBBR) having capacity of 0.5 MLD for treating domestic effluent from toilets, bathrooms and kitchen waste etc received at an invert level all as specified as per drawing of STP, having raw sewage and treated water characterstics as mentioned in PS, consisting 3 times average flow as peak flow with preliminary, secondary and tertiary treatment with all electro mechnical equipments, accessories, all associated civil works, safety equipments, tools, plants and manning for two years of day to day operation and maintenance, Administrative block/laboratory with testing apparatus to test the parameters of various stages of process as per manual of sewage and sewage treatment of CPHEEO, etc complete of function as single, compact and self sustaining type, unit with minimum moving/mechanical equipment from the intake of effluent ofoutlet upto treated water comprising of SS fine screen, Receiving chamber, Screen Chamber, collecting tank (Wet Sump), dry Sump, sewage equalisation tank, receiving chamber, grit channel, anoxic chamber, Raw Sewage pump, MBBR Tanks, Media, Air blowers and Air grid system with air blower room, secondary tube settler, sludge sump, filter press, Sludge drying beds, Hypo dosing system, chlorine dozing appratus, chlorine contact tank, filter feed tank, pressure sand filter, activated carbon filter, treated effluent sump, Sludge drying beds, Hypo dosing system, chlorine dozing appratus, chlorine contact tank,filter feed tank, pressure sand filter, activated carbon filter, treated effluent sump, open drain, piping, interconnections, valves, Electrical Panel, cables, earthing, inspection platform, ladder, railing, footpath, plinth protection, over flow pipe, cover/grading, etc. within the

1

-

-

... More
installation with all measuring instruments, complete all as spd and as given below and all as per technical data sheet attatched as Annexure 'A' to particular specification :- (A) ELECTRO MECHNICAL ITEMS (i) RAW SEWAGE TRANSFER PUMPS Three Nos (Two working and one standby) fully submersible, centrifugal non-clog sewage handling type pump suitable for solid handling of atleast 20 mm dia for raw sewage transfer from collecting tk to equalization tank of capacity : Minimum 20.8 m3/hr and head not less than 15 Meter and Three Nos(two working and one standby) fully submersible, centrifugal non-clog sewage handling type pump suitable for solid handing of atleast 20 mm dia for raw sewage transfer from equalization tk to receivig chamber of capacity : Minimum 200 LPM and head not less than 15 Meter The pump shall have complete CI construction, TEFC induction motor of suitable capacity to run on 400/440V, 3 phase, 50 Hz cycles A/C power supply with single phase preventor, dry run protection etc. including pressure gauge, lifting arrangement for the pump with provision of guide ropes/ rail to guide submersible pump from upper level to operational level in sump basin with suitable channels/angle section and pipeline made of SS-304, valves, level controller electronic type with stainless steel probes/sensors and float switches for automatic operation with pump logic for operation according to flow of sewage, cable, starters,single phase preventer panel, indicators, selector switches, pressure gauges, earthing etc. complete with other accessories as required. (ii) AIR GRID AERATION SYSTEM One set of Header and lateral type coarse air grid system of externally control led with individual down comer line type complete with valves and air distribution grid complete max pressure 6.25

-

-

-

... More
kg/cm2, with pipe line made of SS 304 where ever submerged or else MS class B epoxy painted with all fittings such as tees, crosses, plugs, sockets, elbows, reducers, supporters and clamps, puddle flange, nylon rope braided hose with all accessories to make it retrievable etc with non clog type air dispersion system capable of handling of air with oxygen transfer with efficiency of 3-4% per meter water depth, all as required for equalization tank, MBBR . (iii) AIR BLOWER Two Nos (One working and one stand by) Air Blower twin-type blower (twin lobe root type) with motors/pulleys of capacity 300 m3/hr, head 6250 mm minimum WC driven through 'V' belt or directly coupled through flexible coupling to a TEFC motor of suitable capacity suitable for 400/440 volts, 3 phase, 50 cycles AC supply with single phase preventer, starters including rigid one piece CI casing and side plates, anti friction bearings, suction silencer, discharge silencer, anti vibration pads necessary foundation, common base plate, lubricant oil, etc. complete with valves, NRV, rubber flexible complete all as recommended by OEM. (iv) CHLORINE DOSING SYSTEM One set of Hypo-chlorine solution dozer comprising of 100 Ltrs Cap. HDPE (Chemical grade) tank with inlet/outlet connection of inlet size 10 mm dia along with 01 No. electronic metering pump of adjustable capacity for dosing of chlorine solution (0-4 LPH) with testing and commissioning complete. (v) BAR SCREEN 2 Nos stainless steel bar screen suitable for minimum chamber size as per annexure 'A' to PS comprising of fine screen with suitable lifting arrangement. The fine screen bars shall be of 25 x 5 mm size with 6 mm clear opening and inclined at 45̊ , GI hand rack, bar rack to be provided of SS 304 bars to cover the width of screen

-

-

-

... More
chamber with a racking arm for manual operation. (vi) FLOW METER TOTALIZER : One online electromagnetic water flow meter of suitable dia with totalizer meter, aluminium housing, with Elastomer liner, in treated water line with all accessories complete conforming to environmental protection IP 68/NEMA6/4. End connection should be made of ANSI 150, Electrode material of 316 SS, Metering tube made of SS, output - Analog 4-20 mA, fully isolated, 2 line (vii) PRESSURE GAUGE One lot of stainless steel round dial Pressure gauge of 0-7 kg/cm2 for pumps & 0-1.0 kg/ cm2 pressure having 100 mm dia dial size with suitable valve for on/off of min 15 mm dia for measuring pressure at every required points such as pumps, filters, air lines etc. complete. (viii) MBBR : 02 nos MBBR tank of suitable size as per annexure 'A' made of RCC M 30 with plinth protection, railing, ladder, working platform, rungs etc complete, all as per standard engineering practice of shape and dimension as per OEM with min 0.5 mtr free board with media floating type PP (polypropline) material and shape as per OEM having specific density 0.97 g/cc with necessary SS raiser pipe mesh, MS epoxy coated mesh box for retaining the media within the tank. (ix) TUBE SETTLER 01 no tube setller tank made of RCC M30 with plinth protection, working platform, railing, ladder, rungs, etc complete, all as per standard engineering practice and annexure 'A' with all internal tube settler media hexagonal PVC sheets minimum 2.2 cum with tongue and groove arrangement type, plain settling area at 55 deg angle with : min 7 Sqm/cum surface area. less than 100 mm and provision of 4 nos tube light 1 x 18W LED type with other

-

-

-

... More
accessories and grouting on floor/wall/roof of plant room with suitable primary and secondary supports. (iii) Supply and fix fire point comprising of water (stored presure) fire extinguisher (IS:6234) 9 ltrs capacity - 02 nos, Dry chemical powder (x) SLUDGE DRYING BED : 02 nos sludge drying beds in brick masonry construction of given size and shape capable to air dry/sun dry the digested sludge coming out from tube settler tank with in a given time period cycle as per design. The sludge drying bed shall be provided with PCC channel, filter media comprising of coarse sand under laid by layers of graded gravel, central bed drain/ under drain for collection of filtrate and necessary pipe work for carrying the filtrate to equalization tank. (xi) MISC ITEMS : (a) VALVES : One lot of valves such as gate valves/butterfly valves/Sluice valve/NRV/Air Release valves of suitable size as required. (b) PIPES : All inter-connection piping between Pumps, tanks, filters etc. all as required with stainless steel SS 304 wherever submerged and with MSEP for non submerged pipes as per colour code marked direction of flow and type of sewer within battery limit including tees, bends, flanges, nut bolt, gasket, etc. including necessary primary and secondary supports with masonry work/structural steel work all as required and as specified. (B) MISCELLANEOUS ITEMS (i) One display board of schematic diagram showing flow chart and P&L diagram of the sewage treatment plant drawn on Acrylic white sheet with cloured paints duly marking the details and duly fabricated with suitable aluminium frame of suitable size not less than 1 x 1.5 m. (ii) Supply and fixing glow sign board of size 3000

-

-

-

... More
x 800 x 150 mm, weather proof made of MS angle 50 x 50 x 6 mm with white acrylic sheet 2 mm thick and writing as directed by engineer-in-charge with arial black font of suitable size not exceeding 150 mm but not ABC type of 4.5 Kg capacity- 02 nos, Light weight squeeze grip type CO2 extinguisher (IS:2878) 3 Kg capacity - 02 nos. (D) CIVIL COMPONENTS (i) Construction of sewage treatment plant comprising of SS fine screen,Receiving chamber, Screen Chamber, collectig tank(wet sump), dry sump, Sewage equalisation tank,receiving chamber,grit channel,aoxic chamber, Raw sewage pump, MBBR Tanks, Media, Air blowers and air grid system with air blower room, secondary tube settler, sludge sump,filter press,Sludge drying beds, Hypo dosing system, chlorine dozing apparatus, chlorine contact tank, filter feed tank,pressure sand filter,activated carbon filter,treated effluent sump, and Open Drain etc complete all as per annexure 'A' and all as shown in the flow diagram and as directed by Engr-in-Charge. (ii) All associated civil works for STP such as foundation of pumps, base frame, drains, foot path, ladder, inspection platform, plinth protection, railing around open tanks etc. as required for Electro Mechanical and civil items shall be provided. All raised (above GL) open tanks/structure shall be cordoned off with suitable railing made of MS pipe of 25 mm dia of class 'B' pipe to height of not less than 90 cm painted with two coats of enamel paint over one coat epoxy. All open tanks/ structures at GL are to be provided with epoxy coated MS wire mesh of suitable size and grid not more than 60 x 60 mm duly painted with two coats of enamel paint. MS epoxy coated rungs of suitable size and shape, to access the bar screen pit, oil and grease trap for collection of screening shall be provided. PCC foot path along the sump to a minimum of 1m width will be provided.

-

-

-

... More
(iii) Any other minor civil work required for erection and smooth functioning of sewage treatment plant such as :- (a) Foundation for pumping sets, air blower, sewage pipe line, air lines as per manufacturer design complete. (b) Excavation for pipe line work, cable work foundation supports etc. (c) All mild steel work in rolled steel section MS plates, flat round bolts and nuts etc in necessary structural steel work for supporting /jointing/ fastening sewage water pipes, air lines, drain water pipes etc. (d) painting of two coats of synthetic enameled paint over one coat of red oxide primer of all mild steel pipe/structure as per the standard colour coding of the sewage treatment plant. (e) Painting over on pipe line showing arrow/indicator for flow of sewage water/sludge with distinguished colour and stenciling of major components/for identification and full proof operation of switch gears/indicators. (f) Suitable open drain of PCC considering velocity of not more than 0.8 m/sec for connecting the back wash/overflow/drain from various tanks to the drain sump. The drain shall be covered with suitable MS gratings made of suitable angles/flats and frame made of MS angle iron of suitable size. The drain cover shall be in flush with the top surface of the drain.NOTE 1 1) The tenderer shall be responsible for the sewage treatment plant to provide the treated water characteristics as mentioned in PS irrespective of the qty of effluent flow to STP in the schedule and parameters of inlet Raw sewage given in PS. 2) The tenderer should get the plant installed by any one of the original manufacturer with make mentioned in Appx 'A'. For items in respects where no makes are specified, the recommendation of OEM shall be followed. 3) The technical specifications and capacity of various items in the

-

-

-

... More
schedule are given on not less than basis. In case of any change considered necessary in the technical specifications/capacity of any items given in the schedule to achieve the parameters given in PS, the tenderer should furnish the same 15 days prior to receipt of the tender duly justified with their detailed designe calculations. 4) In the event of non submission of revised specifications/capacity as brought out under note (3) above, and in case of any change considered required in the technical specification/plant capacity of any item during execution stage, the contractor shall provide the same without any cost. The rates quoted by the contractor shall be deemed to have been included for all such changes, which are essential to provide satisfactory performance/functioning of the plant. 5) The contractor shall intimate the name of OEM and submit a certificate from the OEM confirming that the entire plant shall be got executed by them with make as listed in Appx 'A' to tender through them/their accredited agencies before commencement of work .6) Structural drawings of all RCC structres (civil work) required to be constructed in the subject work shall be prepared by the contractor based on soil bearing capacity at the site of work and shall be submitted alongwith soil investigation report duly vetted by IIT/NIIT/Govt. Engg. College within one month of acceptance of tender. All civil structures shall be constructed as per specifications given in the tender documents, the same shall be as per OEM specifications and as per standard codes. Tenderer shall visit the site of work and ascertain the soil bearing capacity by making soil investigation. Lump sum quoted in respect of Schedule 'A' Part IB shall be deemed to have included the cost of above. 7) Civil works like foundation for pumps, ladders for sumps, railing, flooring, plastering etc shall be as per standard engineering practice. 8) All RCC work shall be done with M-30 design mix concrete all as per IS-456 of 200.

-

-

-

... More
9) Any item not covered in scope but required for completion as per standard engineering practice and smooth functioning of STP shall be provided as per OEM and the same shall be deemed to have been included in quoted rates.10) Tenderer shall visit the site and prepare a layout of STP showing all the civil components, plant room, foot path, railing, ladder (external), platform, plingth protection, open drains, over flow pipe, fencing gate etc and get it approved by the accepting officer before commencement of the work duly recommended by GE. 2. Operation and maintenance of sewage treatment plant 0.5 MLD MBBR Type for continuous service by providing 1 skilled and 1 unskilled operators in 2 shifts (starting from 0400Hrs to 1000Hrs & 1200Hrs to 2000Hrs) of 8 hours each from the date of commissioning of STP for 2 years including routine, preventive and breakdown maintenance of plant.All spares/replacement of equipments/any worn out items, if any will be provided by the tenderer at his own cost including all consumables like liquid chlorine, lubricants, oil, grease, bearings, cotton waste etc during the period including disposal off of sludges periodically obtained from sewage treatment to out side of defence land through covered vehicle complete all as specified and directed by Engr-in-Charge. Note: (i) The sludges/cake (manure) obtained from the sewage treatment plant shall be the property of the tenderer and the same shll be disposed off periodically during the manning and operation of plant. The rates quoted by the tenderer are deemed to have taken into consideration of the above aspect. (ii) Testing of treatment sewage for the treated water characteristics given in the tender shall be got done by the contractor from any Govt.

-

-

-

... More
Approved lab or lab approved by GE on quartarly basis during the manning and operation period and the test report shall be submitted to GE. Contractor's quoted rate shall be deemed to have included the same. (iii) The period of comprehensive maintenance of STP will commence from one year after the date of completion.

-

-

-

... More
Design (hydraulically Structurally & Aesthetically), supply, install, erect, connect, test and commissioning and giving satisfactory trials of sewage treatment plant based on the principles of Aerobic attatched growth non clogging randomly Moving Bed Bio Reactor (MBBR) having capacity of 3.0 MLD for treating domestic effluent from toilets, bathrooms and kitchen waste etc received at an invert level all as specified as per drawing of STP, having raw sewage and treated water characterstics as mentioned in PS, consisting 3 times average flow as peak flow with preliminary, secondary and tertiary treatment with all electro mechanical equipments, accessories, all associated civil works, safety equipments, tools, plants and manning for two years of day to day operation and maintenance, Administrative block/laboratory with testing apparatus to test the parameters of various stages of process as per manual of sewage and sewage treatment of CPHEEO, etc complete of function as single, compact and self sustaining type, unit with minimum moving/mechanical equipment from the intake of effluent of outlet upto treated water comprising of SS fine screen, Receiving chamber, Screen Chamber, collecting tank (Wet Sump), dry Sump, sewage equalisation tank, receiving chamber, grit channel, anoxic chamber, Raw Sewage pump, MBBR Tanks, Media, Air blowers and Air grid system with air blower room, secondary tube settler, sludge sump, centrifuge, Sludge drying beds, Hypo dosing system, chlorine dozing appratus, chlorine contact tank, filter feed tank, pressure sand filter, activated carbon filter, treated effluent sump, open drain, piping, interconnections, valves, Electrical Panel, cables, earthing, inspection platform,ladder,railing, footpath, plinth protection, over flow pipe, cover/grading, etc. within the installation with all measuring instruments, complete all as specified and as given below and all as per technical data sheet attatched as Annexure 'A' to particular specification :-

1

-

-

... More
(A) Electro Mechnical Items (i) RAW SEWAGE TRANSFER PUMPS Three Nos (Two working and one standby) fully submersible, centrifugal non-clog sewage handling type pump suitable for solid handling of atleast 20 mm dia for raw sewage transfer from collecting tk to equalization tank of capacity : Minimum 20.8 m3/hr and head not less than 15 Meter and Three Nos(two working and one standby) fully submersible, centrifugal non-clog sewage handling type pump suitable for solid handling of atleast 20 mm dia for raw sewage transfer from equalization tk to receivig chamber of capacity : Minimum 100 LPM and head not less than 15 Meter The pump shall have complete CI construction, TEFC induction motor of suitable capacity to run on 400/440V, 3 phase, 50 Hz cycles A/C power supply with single phase preventor, dry run protection etc. including pressure gauge, lifting arrangement for the pump with provision of guide ropes/ rail to guide submersible pump from upper level to operational level in sump basin with suitable channels/angle section and pipeline made of SS-304, valves, level controller electronic type with stainless steel probes/sensors and float switches for automatic operation with pump logic for operation according to flow of sewage, cable, starters,single phase preventer panel, indicators, selector switches, pressure gauges, earthing etc. complete with other accessories as required. (ii) AIR GRID AERATION SYSTEM One set of Header and lateral type coarse air grid system of externally control led with individual down comer line type complete with valves and air distribution grid complete max pressure 6.25 kg/cm2, with pipe line made of SS 304 where ever submerged or else MS class B epoxy painted with all fittings such as tees, crosses, plugs, sockets, elbows, reducers, supporters and clamps, puddle flange, nylon rope braided hose with all accessories to make it

-

-

-

... More
retrievable etc with non clog type air dispersion system capable of handling of air with oxygen transfer with efficiency of 3-4% per meter water depth, all as required for equalization tank, MBBR . (iii) AIR BLOWER : Two Nos (One working and one stand by) Air Blower twin-type blower (twin lobe root type) with motors/pulleys of capacity 1300 m3/hr, head 6250 mm minimum WC driven through 'V' belt or directly coupled through flexible coupling to a TEFC motor of suitable capacity suitable for 400/440 volts, 3 phase, 50 cycles AC supply with single phase preventer, starters including rigid one piece CI casing and side plates, anti friction bearings, suction silencer, discharge silencer, anti vibration pads necessary foundation, common base plate, lubricant oil, etc. complete with valves, NRV, rubber flexible complete all as recommended by OEM. (iv) CHLORINE DOSING SYSTEM One set of Hypo-chlorine solution dozer comprising of 100 Ltrs Cap. HDPE (Chemical grade) tank with inlet/outlet connection of inlet size 10 mm dia along with 01 No. electronic metering pump of adjustable capacity for dosing of chlorine solution (0-4 LPH) with testing and commissioning complete. (v) BAR SCREEN 2 Nos stainless steel bar screen suitable for minimum chamber size as per annexure 'A' to PS comprising of fine screen with suitable lifting arrangement. The fine screen bars shall be of 25 x 5 mm size with 6 mm clear opening and inclined at 450, GI hand rack, bar rack to be provided of SS 304 bars to cover the width of screen chamber with a racking arm for manual operation. (vi) FLOW METER TOTALIZER : One online electromagnetic water flow meter of suitable dia with totalizer meter, aluminium housing, with Elastomer liner, in treated water line with all accessories complete conforming to environmental protection IP 68/NEMA6/4. End connection should

-

-

-

... More
be made of ANSI 150, Electrode material of 316 SS, Metering tube made of SS, output - Analog 4-20 mA, fully isolated, 2 line LCD display, Glass loaded polycarbonate enclosure and polycarbonate window, accuracy - 0.2% suitable for operation on 85 - 265 V AC, working temperature 10- 600°C of flow 0-50 m3/hr complete incl, testing and commissioning all as specified and directed. LCD display, Glass loaded polycarbonate enclosure and polycarbonate window, accuracy - 0.2% suitable for operation on 85 - 265 V AC, working temperature 10- 600°C of flow 0-50 m3/hr complete incl, testing and commissioning all as specified and directed. (vii) PRESSURE GAUGE One lot of stainless steel round dial Pressure gauge of 0-7 kg/cm2 for pumps & 0-1.0 kg/ cm2 pressure having 100 mm dia dial size with suitable valve for on/off of min 15 mm dia for measuring pressure at every required points such as pumps, filters, air lines etc. complete. (viii) MBBR : 02 nos MBBR tank of suitable size as per annexure 'A' made of RCC M 30 with plinth protection, railing, ladder, working platform, rungs etc complete, all as per standard engineering practice of shape and dimension as per OEM with min 0.5 mtr free board with media floating type PP (polypropline) material and shape as per OEM having specific density 0.97 g/cc with necessary SS raiser pipe mesh, MS epoxy coated mesh box for retaining the media within the tank. (ix) TUBE SETTLER 01 no tube setller tank made of RCC M30 with plinth protection, working platform, railing, ladder, rungs, etc complete, all as per standard engineering practice and annexure 'A' with all internal tube settler media hexagonal PVC sheets minimum 2.2 cum with

-

-

-

... More
tongue and groove arrangement type, plain settling area at 55 deg angle with : min 7 Sqm/cum surface area. (x) SLUDGE DRYING BED : 02 nos sludge drying beds in brick masonry construction of given size and shape capable to air dry/sun dry the digested sludge coming out from tube settler tank with in a given time period cycle as per design. The sludge drying bed shall be provided with PCC channel, filter media comprising of coarse sand under laid by layers of graded gravel, central bed drain/ under drain for collection of filtrate and necessary pipe work for carrying the filtrate to equalization tank. (xi) MISC ITEMS : (a) VALVES One lot of valves such as gate valves/butterfly valves/Sluice valve/NRV/Air Release valves of suitable size as required. (b) PIPES : All inter-connection piping between Pumps, tanks, filters etc. all as required with stainless steel SS 304 wherever submerged and with MSEP for non submerged pipes as per colour code marked direction of flow and type of sewer within battery limit including tees, bends, flanges, nut bolt, gasket, etc. including necessary primary and secondary supports with masonry work/structural steel work all as required and as specified. (B) MISCELLANEOUS ITEMS (i) One display board of schematic diagram showing flow chart and P&L diagram of the sewage treatment plant drawn on Acrylic white sheet with cloured paints duly marking the details and duly fabricated with suitable aluminium frame of suitable size not less than 1 x 1.5 m.

-

-

-

... More
(ii) Supply and fixing glow sign board of size 3000 x 800 x 150 mm, weather proof made of MS angle 50 x 50 x 6 mm with white acrylic sheet 2 mm thick and writing as directed by engineer-in-charge with arial black font of suitable size not exceeding 150 mm but not less than 100 mm and provision of 4 nos tube light 1 x 18W LED type with other accessories and grouting on floor/wall/roof of plant room with suitable primary and secondary supports. (iii) Supply and fix fire point comprising of water (stored presure) fire extinguisher (IS:6234) 9 ltrs capacity - 02 nos, Dry chemical powder ABC type of 4.5 Kg capacity- 02 nos, Light weight squeeze grip type CO2 extinguisher (IS:2878) 3 Kg capacity - 02 nos. (D) CIVIL COMPONENTS (i) Construction of sewage treatment plant comprising of SS fine screen,Receiving chamber, Screen Chamber, collectig tank(wet sump), dry sump, Sewage equalisation tank,receiving chamber,grit channel,aoxic chamber, Raw sewage pump, MBBR Tanks, Media, Air blowers and air grid system with air blower room, secondary tube settler, sludge sump,filter press,Sludge drying beds, Hypo dosing system, chlorine dozing apparatus, chlorine contact tank, filter feed tank,pressure sand filter,activated carbon filter,treated effluent sump, and Open Drain etc complete all as per annexure 'A' and all as shown in the flow diagram and as directed by Engineer-in-Charge. (ii) All associated civil works for STP such as foundation of pumps, base frame, drains, foot path, ladder, inspection platform, plinth protection, railing around open tanks etc. as required for Electro Mechanical and civil items shall be provided. All raised (above GL) open tanks/structure shall be cordoned off with suitable railing made of MS pipe of 25 mm dia of class 'B' pipe to height of not less than 90 cm painted with two coats of enamel paint over one coat epoxy. All open tanks/ structures at GL are to be provided

-

-

-

... More
with epoxy coated MS wire mesh of suitable size and grid not more than 60 x 60 mm duly painted with two coats of enamel paint. MS epoxy coated rungs of suitable size and shape, to access the bar screen pit, oil and grease trap for collection of screening shall be provided. PCC foot path along the sump to a minimum of 1m width will be provided. (iii) Any other minor civil work required for erection and smooth functioning of sewage treatment plant such as :- (a) Foundation for pumping sets, air blower, sewage pipe line, air lines as per manufacturer design complete. (b) Excavation for pipe line work, cable work foundation supports etc. (c) All mild steel work in rolled steel section MS plates, flat round bolts and nuts etc in necessary structural steel work for supporting /jointing/ fastening sewage water pipes, air lines, drain water pipes etc. (d) painting of two coats of synthetic enameled paint over one coat of red oxide primer of all mild steel pipe/structure as per the standard colour coding of the sewage treatment plant. (e) Painting over on pipe line showing arrow/indicator for flow of sewage water/sludge with distinguished colour and stenciling of major components/for identification and full proof operation of switch gears/indicators. (f) Suitable open drain of PCC considering velocity of not more than 0.8 m/sec for connecting the back wash/overflow/drain from various tanks to the drain sump. The drain shall be covered with suitable MS gratings made of suitable angles/flats and frame made of MS angle iron of suitable size. The drain cover shall be in flush with the top surface of the drain. NOTE 1 1) The tenderer shall be responsible for the sewage treatment plant

-

-

-

... More
to provide the treated water characteristics as mentioned in PS irrespective of the qty of effluent flow to STP in the schedule and parameters of inlet Raw sewage given in PS.2) The tenderer should get the plant installed by any one of the original manufacturer with make mentioned in Appx 'A'. For items in respects where no makes are specified, the recommendation of OEM shall be followed. 3) The technical specifications and capacity of various items in the schedule are given on not less than basis. In case of any change considered necessary in the technical specifications/capacity of any items given in the schedule to achieve the parameters given in PS, the tenderer should furnish the same 15 days prior to receipt of the tender duly justified with their detailed designe calculations. 4) In the event of non submission of revised specifications/capacity as brought out under note (3) above, and in case of any change considered required in the technical specification/plant capacity of any item during execution stage, the contractor shall provide the same without any cost. The rates quoted by the contractor shall be deemed to have been included for all such changes, which are essential to provide satisfactory performance/functioning of the plant. 5) The contractor shall intimate the name of OEM and submit a certificate from the OEM confirming that the entire plant shall be got executed by them with make as listed in Appx 'A' to tender through them/their accredited agencies before commencement of work. 6) Structural drawings of all RCC structres (civil work) required to be constructed in the subject work shall be prepared by the contractor based on soil bearing capacity at the site of work and shall be submitted alongwith soil investigation report duly vetted by IIT/NIIT/Govt. Engg. College within one month of acceptance of tender. All civil structures shall be constructed as per specifications

-

-

-

... More
given in the tender documents, the same shall be as per OEM specifications and as per standard codes. Tenderer shall visit the site of work and ascertain the soil bearing capacity by making soil investigation. Lump sum quoted in respect of Schedule 'A' Part IB shall be deemed to have included the cost of above. 7) Civil works like foundation for pumps, ladders for sumps, railing, flooring, plastering etc shall be as per standard engineering practice. 8) All RCC work shall be done with M-30 design mix concrete all as per IS-456 of 200. 9) Any item not covered in scope but required for completion as per standard engineering practice and smooth functioning of STP shall be provided as per OEM and the same shall be deemed to have been included in quoted rates. 10) Tenderer shall visit the site and prepare a layout of STP showing all the civil components, plant room, foot path, railing, ladder (external), platform, plingth protection, open drains, over flow pipe, fencing gate etc and get it approved by the accepting officer before commencement of the work duly recommended by GE. 2. Operation and maintenance of sewage treatment plant 3.0 MLD MBBR Type for continuous service by providing 1 skilled and 1 unskilled operators in 2 shifts (starting from 0400Hrs to 1000Hrs & 1200Hrs to 2000Hrs) of 8 hours each from the date of commissioning of STP for 2 years including routine, preventive and breakdown maintenance of plant. All spares/replacement of equipments/any worn out items, if any will be provided by the tenderer at his own cost including all consumables like liquid chlorine, lubricants, oil, grease, bearings, cotton waste etc during the period including disposal off of sludges periodically obtained from sewage treatment to out side of defence land through covered vehicle complete all as specified and directed by Engr-in-Charge.

-

-

-

... More
Note: (i) The sludges/cake (manure) obtained from the sewage treatment plant shall be the property of the tenderer and the same shll be disposed off periodically during the manning and operation of plant. The rates quoted by the tenderer are deemed to have taken into consideration of the above aspect. (ii) Testing of treatment sewage for the treated water characteristics given in the tender shall be got done by the contractor from any Govt. Approved lab or lab approved by GE on quartarly basis during the manning and operation period and the test report shall be submitted to GE. Contractor's quoted rate shall be deemed to have included the same. (iii) The period of comprehensive maintenance of STP will commence from one year after the date of completion.

-

-

-

... More
Total amount of SCHEDULE 'A' PART-II (INTERNAL WATER SUPPLY) (For details see Items of Schedule 'A' Part-II in PDF folder)

1

-

34831.2

... More
Total amount of SCHEDULE 'A' PART-III A (INTERNAL ELECTRIFICATION) (For details see Items of Schedule 'A' Part-III A in PDF folder)

1

-

103996.2

... More
SCHEDULE 'A' PART-III-B (INTERNAL ELECTRIFICATION)

-

-

-

... More
S&F LUMILINE 20 Watt LED, High lumen batten with efficacy of 100 lumens per Watt , 230V, Surface /Wall mounting, with integrated electronic driver high transcluent frosted diffuser, bipin holders, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.Make:- Havells, Model- LUMILINE, LUMILINE BS20WLED840SPCWH or eqvlt in Philips/ Havells.all as specified and directed by engr-in-charge.

33

-

-

... More
Supply & Fixing Lamp holder/Batten holder with PVC/Polycarbonate body angular/straight fixed on plastic laminated sheet cover round shape 3 mm thick including 01 No LED 10 W suitable for 230 V complete all as specified and directed.

18

-

-

... More
S&F Exhaust Fan 300 mm sweep metal body with louver shutter complete fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 23/0.0076 copper cable, rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthetic enamel paint 2.0 cm high complete for offrs toilets all as specified and directed. Make - Bajaj, Model- Bajaj maxima 250 mm.

9

-

-

... More
Supply & Fixing energy saving ceiling fan complete without regulator 230 volts single phase 1200 mm sweep including canopy set,down rod and shackle assembly, Fan hook including providing three core copper conductor cable of size 1.5 Sq mm 3 core from fittings to ceiling rose or connector and writing MES No. with black synthetic enamel paint 2.0 cm high complete all as specified and directed by EIC including cost of 15 mm GI Pipe medium grade upto 1.5 mtr duly painted with matching colour for hanging of ceiling fan where required. Make - Havells.

9

-

-

... More
S&F LED linear mirror light Aesthetically designed, Provided with a high output PMMA diffuser for glare free light 7 watt. Dimension: 300 mm. incl lamp etc. complete with all accessories in and including connecting up with twin core twisted flexible copper conductor cable with suitable size copper wire complete all as specified and directed.

3

-

-

... More
Supply & fix Energy saving and environmental friendly long life LED street light 25 watt made up of pressure die cast aluminium housing with high power LED as lighting source and lens embendded PC cover having TOP OPENING separate driver compartment with IP 65 protection and impact resistance of IK07 including taking down of existing street light any type including cost of GI pipe, bracket, clamps, nut & bolts etc required for fixing of fittings all as specified and directed by engr-in-charge. Make:- Havells, Model-Endura Pearl, Code -LHETBXU7PA6S025 (Suitable for pole dia 43 mm max.)

36

-

-

... More
S&F blanking plate complete all as specifed and directed.

6

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick, buired directly in ground ( earth pit not less then 2.25 meters deep below ground level) with using 4 Sqmm galvanised iron wire as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3, with top edge of the plate not less then 1.5 meters below normal ground level, surrounded from all sides by charcoal dust and common salt in alternative layers of 15cm depth and earth connected with equipment by means of bolts, nuts, check nuts and washers of galvanised iron and connection to earth mesh including welding and complete with fire charcoal after installing earth strip , earth work and filling pit with PCC 1:2:4 type B1 using 20mm graded stone aggregate as in pit chamber and RCC pit cover 50mm thick precast (1:1.5:3) reinforced with MS round bars 6mm dia @ 150c/c both ways and with 10mm dia MS bar in lifting handle complete all as specified and as directed.

9

-

-

... More
Total amount of SCHEDULE 'A' PART-IV ( EARTH WORK) (For details see Item of Schedule 'A' Part-IV in PDF folder)

1

-

7165532.06

... More
Total amount of SCHEDULE 'A' PART-V (DEMOLITION/ DISMANTLING) (For details see Items of Schedule 'A' Part-V in PDF folder)

1

-

265581.2

... More
Total amount of SCHEDULE 'A' PART-VI ( ROAD, PATH, CULVERT AND HARD STANDING) (For details see Items of Schedule 'A' Part- VI in PDF folder)

1

-

6422782.29

... More
SCHEDULE 'A' PART-VII A (EXTERNAL WATER SUPPLY) (For details see Items of Schedule 'A' Part- VII A in PDF folder)

1

-

4392350.2

... More
SCHEDULE 'A' PART-VII B (EXTERNAL WATER SUPPLY) DISPOSAL OF SEWAGE WATER

-

-

-

... More
Supply and install Pumping set centrifugal, elrctric driven,10 HP, 400 LPM, at 50mtr head inclusive of starter and PCC foundation complete.

4

-

-

... More
Supply and install Pumping set centrifugal, elrctric driven 20HP, 800 LPM, at 50 mtr Head inclusive of starter and PCC foundation complete

2

-

-

... More
Supply and fix steel pipe ERW steel including specials, nominal dia 150 mm as per IS 1239 thickness 4.8 mm complete all as specified and directed.

20

-

-

... More
Supply & Fixing valve,reflux, with bypass arrangements, flanged ends complete including rubber/fiber board gasket, nuts washer etc of 100 mm dia

6

-

-

... More
Supply and fixing C.I double acting air valve of approved quality with bolts, nutsrubber insertion etc, complete of 100 mm dia

3

-

-

... More
Supply and fixing PVC insulated submersible copper cable 3 core/ multi core flat/ round of size 6 Sqmm complete all as specified and directed by Engr-in-charge.

200

-

-

... More
SCHEDULE 'A' PART-VIII (EXTERNAL ELECTRIC SUPPLY)

-

-

-

... More
Supply & Fixing prestressed concrete 11 meter long pole , 152mmx152mm at top and 152 mm x 260 mm at bottam class 9 complete all as specified and directeed by Engr-in-charge.( For Two pole structure) Note :- Excavation, MS work and PCC work will be measured and paid separately.

6

-

-

... More
Supply & Fixing for mild steel work as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot , drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.

12

-

-

... More
Supply & Fixing of cradles, hexagonal/ rectangular fabricated with galvanised steel wire of size 4mm dia complete all as specified and directed by Engr-in- charge.

1

-

-

... More
Supply & Fixing switch air break gang operated triple pole mechanically operated mounted on HT 11KV outdoor for horizontal or vertical mounting insulators and mild steel galvanized frame with operating rod of 20mm bore medium grade galvanized iron pipe worked from ground level for current rating 200 Amps including nuts, bolts and washers etc of required size,having 9 insulators of capacity to suit the load at site including locking arrangement with locks and synthetic enamel paint over a coat of red oxide primer over mild steel work and electric connection complete all as specified and directed. Make : Pactil/ Jaipuria Bros/ Rashtriya.

3

-

-

... More
Supply, testing jointing and commissioning heat shrinkable straight throught joint kit out door type complete with jointing material and accessories suitable for 16 to 50 Sqmm 3.5 core XLPE 1100 Volt armoured aluminium conductor complete all as specified and directed by Enger-in-charge.

10

-

-

... More
Supply, installation, testing and commissioning out door type cubical panel board of size 3.5mtrX 2.5 mtr X 0.6 mtr outer shell made out of 3.15mm thick MS sheet and inner shell made out of 2mm thick MS sheet and MS angle section 50 x 50x 6mm (Angle iron frame 40 cm above top edge of plateform) on PCC 1:2:4 type B-1 platform 60cm above the ground level and 45cm below the ground level, factory fabricated with front and back openable double door system (each door hinged with body at 4 places) lockable, openable by keys, having chromium plated 19 mm dia fancy lock, louvers and air vent, gasket 'u' type for natural flow of air, complete dust & vermin proof suitable for 3 phase 4 wire 415 volt 50 Hz factory fabricated (factory approved from CPRI)having modern fabrication followed by powder coated painting having thickness not less than 100 microns including making connections with aluminium strip conductor and general construction conforming to IS-8623 of 1993 comprising of the following :- (a) TPN aluminium bus bar 800 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators - 01 Set (b) Incoming ACB 800 Amp, 4 pole 415 volts 50 Hz 35 KA AC with micro prosaser release setting -01 (c) Outgoing MPCB 200 Amp, 3 pole 415 volts 50 Hz 36 KA AC with adjustable thermal release setting - 01

3

-

-

... More
(d) Outgoing MPCB 100 Amp, 3 pole 415 volts 50 Hz 25 KA AC with adjustable thermal release setting - 08 (e) Digital voltmeter 0-500 volts of size 96 x 96 Sqmm with three way selector switch –01 No Make : AE/MECO (f) Digital Ammeter 0-800 Amps of size 96 x 96 Sqmm with three way rotary selector switch- 01 No Make : AE/MECO (g) Indicating lamp RYB with holder – 01 Set of three Make : Siemens/L&T ( h) Fully automatic star delta starter suitable for 10 to 40 HP non clog sewage submersable pump - 08 Nos (j) Automatic phase sequence corrector for auto reset of RYB phase. (k) ON Load Change Over Switch 4 pole 650 Amps as per IS 13947 - 01 Nos

-

-

-

... More
Supply and Fixing steel tubular pole in true vertical (or be planted as strut) complete with cast iron base plate 6mm thick 300x300mm, final taper, plug, bolts, nuts & washers as specified type 410 SP-55 (11.0 mtr long) conforming to IS-2713 Part II type including, cable, street light fittings, clamps, nuts & bolts etc including painting with one cost or red oxide primer and two coats of silver aluminium paint for exposed surface and two coat of black bituminous paint for portion embedded in concrete excavation, MS work and PCC work are inclusiveincluding S&F flooding LED 120 watt with accessories-04 Nos Make : C&S cat part No LTEF120 WHPLED or equivalent in Havells cat part No LHELANU7PG6J1120/ Bajaj/Surya inclusive of mild steel work as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, dirilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint , including FRP junction box Make (Sintex or size 317 mmx265mmx160 mm cat part No GS-JB-3126) with 32 Aprs MCB TPN ( Make Legrand cat part No 408680)

6

-

-

... More
with the help of MS Nuts bolts and MS Clamps-1 Nos of size 40mmx5mm thick capacity and PVC cable 2.5 sqmm Aluminium wire upto 7.5 mtr length for connection of security light from junction box on existing pole to take out connections to fitting if required at site complete all as specified and directed

-

-

-

... More
Suplly and install First aid box complete for each installation and direction by Engr-in-charge.

15

-

-

... More
supply and fixing intallation glow sign board of size 2000 x 800 x 150mm (horizontal orientation) for each installation , size and shape of letter decided by Engr-in-charge including lighting system complete all as specified and directed by Engr-in-charge.

12

-

-

... More
supply and fixing glow sign chart of size 1700 x 1000 x 150mm (vertical orientation) for inside the installation to write the detail of motor , pump and istallation including electric safety chart etc complete, size and shape of letter decided by Engr-in-charge including lighting system complete all as specified and directed by Engr-in-charge.

12

-

-

... More
Supply & fixing Rubber Mats confirming to IS 15652 Black chequered type of size 1 mtr x 2 mtr x 3 mm ISI mark complete all as specified and as directed by Engineer-in Charge Make: Jyoti/ National

15

-

-

... More
Supply and fix cable route indicator for HT cable, size and shape of indicator as per IS or as directed by Engr-in-Charge

480

-

-

... More
Supply and fix Ceasefire ABC powder Map 90-4 Kg, fire extinguisher, stored pressure type,pressure gauge, controllable disharge mechanism, range, minimum 4 mtr, applicable on glass ABC and electrically started fire, internal coating of can Epoxy powder coating, sheet metal thickness 1.60 mm helium leak detection tested ISI and CE approved Make Ceasefire

12

-

-

... More
Supply and lay to installation Gas mask, Gum boot and glubs etc complete for safty of FGM as directed by Engr-in-Charge.

15

-

-

... More
Supply and Fixing danger notice plate 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in single red colour and fixed with MS clamps, bolts and nuts of approved size, HT 25x20 cmm size complete all as specified and directed by Engr-in-Charge

6

-

-

... More
Supply and fixing for cement concrete 1:3:6 type C-2 using 40mm graded aggregate including necessary form work all as specified.

4

-

-

... More
Supply and fixing aluminium conductor, steel reinforced including binding wire and jumper connect with PG clamp made out of aluminium alloy according to IS-617 complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Supply and fixing lighting arresters zinc oxide type complete with all fittings, transmission class, discharge capacity 65 kilo amps complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply , laying & testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavt duty) with standard aluminium conductor, 11000 volts grade, of size 3 core 95 Sq mm.

2400

-

-

... More
Supply, fixing & testing cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 95 sqmm 3 core XLPE armoured aluminium conductor complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
Supply, fixing & testing cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 95 sqmm 3 core XLPE armoured aluminium conductor complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
Supply and installation of transformer step up/down, out door type complete copper wound AC Phase, 4 wire, 50 htz step down outdoor, 11000/433 Volts (at no load), double wound, oil cooled with external cooling tubes, core type, de (a) 03 nos , porcelain HV brushing wiith arching horns on HV side suitable for 11 KV complete with brushing rod, nuts & washers. (b) One cable end box on LV side consisting of 04 Nos procelain bushing suitable for LT armoured cable with brushing rod, glands, joints etc. (c) Oil conservator with filter type drain valve and oil gauge.(d) Dehydrating silica gel beather with first full of dehudrating agent/silica gel. (e) Explosive vent. (f) Thermometer pocket of tank cover. (g) One 3 No 100 mm dia thermometer vapor pressure type having range 0-120 Degree Centigrade with minimum reading pointer, maximum temperature indicator and resetting device. (h) Rating plate with terminal marking. (i) Two earthing terminal on tank. (j) Oil levewl gauge. (k) Oil drain valve. (l) Lifting lugs (m) Oil filter hole with cap/plug incl connection. (n) Air release valve plug.

-

-

-

... More
(o) For playing solid cast steel detachable rollers. (p) Extra bushing for netural outside cable box providing independenty earthing for neutral.

-

-

-

... More
(a) -do- but 100 KVA

1

-

-

... More
(b) -do- but 125 KVA

2

-

-

... More
Supply, laying and testing cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor of size 50 Sqmm 3.5 Core. (for transformer to Panel & DG Set to Panel)

800

-

-

... More
Supply, laying and testing cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor of size 16 Sqmm 4 Core. (for staff Qtr))

600

-

-

... More
Supply, testing jointing and commissioning heat shrinkable and termination joint kit outdoor type complete with jointing material and accessories suitable for 16 to 50 Sqmm 3.5 Core XLPE 1100 Volt armoured aluminium conductor complete all as specified and directed by Engr-in-Charge.

55

-

-

... More
Total amount of SCHEDULE 'A' PART-IXA (SEWAGE DISPOSAL PUMPING) (For details see Items of Schedule 'A' Part-IX A in PDF folder)

1

-

1924907

... More
SCHEDULE 'A' PART-IX B (SEWAGE DISPOSAL (PUMPING))

-

-

-

... More
Supplying and lay pipe Ductile Iron , S/S including specials, class K -7 of following sizes:-

-

-

-

... More
(i) 100 mm dia

5445

-

-

... More
(ii) 150 mm dia

658

-

-

... More
Supply and fixing C.I double acting air valve of approved quality with bolts, nutsrubber insertion etc, complete of 100 mm dia

12

-

-

... More
Supply and installation non clog sewage submersible pump with chrome steel impaller and cutter, non clog to pass 40 mm size particales, with guide rail pipe,duck foot bend and lifting chain including PCC foundation ,testing etc complete of following sizes :-

-

-

-

... More
(i) 7.5 HP (600 LPM x 40 M )

22

-

-

... More
(ii) 10 HP (900 LPM x 40 M )

2

-

-

... More
S&F PVC insulated submersible copper cable 3 core/multi core flat/round of size 10 sqmm

450

-

-

... More
Supply and laying XLPE insulated armoured heavy duty electric cable as per IS 7098 with aluminium conductor 1100 volts grade with cross sectional area 35 Sqmm 3.5 core .(for Pole to starter Panel & DG set to starter Panel )

2000

-

-

... More
Supply, installation, testing and commissioning out door type cubical panel board of size 2.5mtrX 1.5 mtr X 0.6 mtr outer shell made out of 3.15mm thick MS sheet and inner shell made out of 2mm thick MS sheet and MS angle section 50 x 50x 6mm (Angle iron frame 40 cm above top edge of plateform) on PCC 1:2:4 type B-1 platform 60cm above the ground level and 45cm below the ground level, factory fabricated with front and back openable double door system (each door hinged with body at 4 places) lockable, openable by keys, having chromium plated 19 mm dia fancy lock, louvers and air vent, gasket 'u' type for natural flow of air, complete dust & vermin proof suitable for 3 phase 4 wire 415 volt 50 Hz factory fabricated (factory approved from CPRI)having modern fabrication followed by powder coated painting having thickness not less than 100 microns including making connections with aluminium strip conductor and general construction conforming to IS-8623 of 1993 comprising of the following :- (a) TPN aluminium bus bar 200 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable

12

-

-

... More
size “F” class insulators - 01 Set (b) Incoming MCCB 160 Amp, 4 pole 415 volts 50 Hz 35 KA AC with micro prosaser release setting -01 (c) Outgoing MCCB 100 Amp, 3 pole 415 volts 50 Hz 25 KA AC with adjustable thermal release setting - 02 (d) Digital voltmeter 0-500 volts of size 96 x 96 Sqmm with three way selector switch –01 No (e) Digital Ammeter 0-160 Amps of size 96 x 96 Sqmm with three way rotary selector switch- 01 No (f) Indicating lamp RYB with holder – 01 Set of three (g) Change over switch 160 Amps-01 Nos ( h) Fully automatic star delta starter suitable for 10 to 20 HP non clog sewage submersable pump - 02 Nos (j) Automatic phase sequence corrector for auto reset of RYB phase.

-

-

-

... More
Material & Labour for brick masonry valve pit of internal size 150cm x150cm x 150cm with one brick thick wall using sub class ‘B’ brick in cement mortar 1:6 over 20cm thick PCC plate form with 15cm off sets on every side of 1:3:6 type C-1 including plastering of internal surfaces and exposed surfaces with 15mm thick plastering in cement mortar 1:4 and 50mm thick RCC cover (in two equal parts 1:2:4 type B-1 with 10mm dia deformed bars at 10cm interval on both side including necessary form work with 150mm dia hole in the center complete all as specified and as directed by Engineer-in-Charge

36

-

-

... More
Supply and fix chain pulley block capacity 2 ton, manualy operated by hand chain wheel & hand chain including manufactureing of high quality lifting equipment including suitable size of tripod complete all as specified and directed by Enger-in-charge.

12

-

-

... More
Supply and laying fire brick laid in trenches all as specified and directed by Enger-in-charge.

250

-

-

... More
Total amount of SCHEDULE 'A' PART-X (Sewage Disposal Branch/ Gravity Line)(For details see Items of Schedule 'A' Part-X in PDF folder)

1

-

19738965.11

... More
Total amount of SCHEDULE 'A' PART-XI (FENCING, GATE, AND COMPOUND WALL/SECURITY WALL) (For details see Items of Schedule 'A' Part-XI in PDF folder)

1

-

4939038.25

... More
SCHEDULE 'A' PART-XII (SCADA SYSTEM)

-

-

-

... More
Supply, Installation, Testing and Commissioning of PLC (Programmable Logic Controller) based Indoor Monitoring / Annunciating Control Panel with inbuilt wireless DUAL SIM Card based GPRS communication modem and suitable antenna (at Sewage P/H No.1 to 12) for Automatic Non Clog Submersible Pump Control / Protection suitable for 02 nos. Pumps, 02 nos. Pressure Switches, 01 no. Ultrasonic Level Sensor and 01 no.Sump. The panel should be of suitable size fabricated from 1.6 mm thick CRCA sheet and properly powder coated. It shall be floor mounted on properly powder coated sheet metal stand of suitable size.. The Panel should be capable of carrying out the below mentioned activities :- (a) Water Level Sensing & Display (b) Manual Mode Operation. (c) The 01 No. PLC based Panel shall consist of with following specifications:- (i) PLC should be suitable no. of Digital / Analog inputs / outputs. (ii) 2 serial ports supporting open communication protocol. (iii) Programming software based on IEC to facilitate building of custom built function blocks. Note : Make for PLC :- Siemens/ GE FANUC / Schneider/ mitsubishi/ Rockwell Automation (ii) 01 No. HMI - 4.3" (min) Graphical Touch screen multicolor having following minimum features a. 02 nos. serial ports and 01 no. USB port ,

12

-

-

... More
Item No 1 Contd/… b. Floating Point support c. Built in RTC d. Bar Graph and image (bmp, jpeg files) e. Real time and historical Trending, f. Real time and historical alarms (iii) 01 No. SMPS of 5 A rating (Make: SCHNEIDER / NHP) (iv) Suitable No. of interposing relays 24 V D.C. and 230 V A.C. coil rating and 6 A contact rating (Make: OEN / OMRON / IDEC / ALLEN BRADLEY) , (vi)1.0 KVA UPS / INVERTER with Sealed Maintenance free Batteries for powering the panel for a minimum of 30 minutes in case of supply failure. (Make: APC / TATA LIEBERT / NUMERIC / LUMINOUS) (vii) Transformer of suitable rating (viii) MCB of suitable rating (Make: Havells/ Schneider) (ix) Illuminated Push Buttons, Push Buttons and Indicator Lamps as per requirement (Make: SCHNEIDER / ESBEE or equivalent) (x) Selector Switches as per requirement (Make: SCHNEIDER / ESBEE or equivalent) (xi) Audio Visual Alarm Indicator (Make: MIMIC / ESBEE / SCHNEIDER). Make: - Recktronic Devices and system / Marsh Automation Pvt. Ltd. / Concepts & Solutions

-

-

-

... More
Supply, Installation, Testing and Commissioning of PLC (Programmable Logic Controller) based Indoor Monitoring / Annunciating Control Panel with inbuilt wireless DUAL SIM Card based GPRS communication modem and suitable antenna (at STP No.1 to 3) for Automatic Control / Protection suitable for 09 nos. Pumps, 03 nos. Air Compressor, 12 nos. Pressure Switches, 04 nos. Ultrasonic Level Sensors. The panel should be of suitable size fabricated from 1.6 mm thick CRCA sheet and properly powder coated. It shall be floor mounted on properly powder coated sheet metal stand of suitable size.. The Panel should be capable of carrying out the below mentioned activities (a) Water Level Sensing & Display (b) Manual Mode Operation. (c) The 01 No PLC based Panel shall consist of with following specifications:- (i) PLC should be suitable no. of Digital / Analog inputs / outputs. (ii) 2 serial ports supporting open communication protocol. (iii) Programming software based on IEC to facilitate building of custom built function blocks.

3

-

-

... More
Item No 2 Contd/... Note : Make for PLC :- Siemens/ GE FANUC / Schneider/ mitsubishi/ Rockwell Automation/ Sombansi Enviro Engg Pvt Ltd (SEEPL) (ii) 01 No. HMI - 7" (min) Graphical Touch screen multicolor having following minimum features a. 02 nos. serial ports and 01 no. USB port , b. Floating Point support c. Built in RTC d. Bar Graph and image (bmp, jpeg files) e. Real time and historical Trending, f. Real time and historical alarms (iii) 01 No. SMPS of 5 A rating (Make: SCHNEIDER / NHP) (iv) Suitable No. of interposing relays 24 V D.C. and 230 V A.C. coil rating and 6 A contact rating (Make: OEN / OMRON / IDEC / ALLEN BRADLEY) , (vi)1.0 KVA UPS / INVERTER with Sealed Maintenance free Batteries for powering the panel for a minimum of 30 minutes in case of supply failure. (Make: APC / TATA LIEBERT / NUMERIC / LUMINOUS) (vii) Transformer of suitable rating (viii) MCB of suitable rating (Make: Havells/ Schneider) (ix) Illuminated Push Buttons, Push Buttons and Indicator Lamps as per requirement (Make: SCHNEIDER / ESBEE or equivalent) (x) Selector Switches as per requirement (Make: SCHNEIDER / ESBEE or equivalent) (xi) Audio Visual Alarm Indicator (Make: MIMIC / ESBEE / SCHNEIDER). Make: - Recktronic Devices and system / Marsh Automation Pvt. Ltd. / Concepts & Solutions / Sombansi Enviro Engg Pvt Ltd (SEEPL).

-

-

-

... More
Supply, Installation, Testing, Commissioning and Programming of Engineering Control station comprising of :- (a) Supply of integrated smart station platform (multiple access) having module for monitoring and/or control of STP. The smart station platform shall be user configurable with respect to all critical features viz. landing page, drop down tabs and menus, report formats, alerts and notifications. Note : The scope of work includes provisions of new wired broad band connection alongwith static IP in the name of GE along with call costs for a period of 12 months including suitable the interest charges for 12 months. This IP address shall be used for GPRS communications between the SCADA based Engineering control centre & the PLC based panels. Make : Recktronic Devices and Systems

1

-

-

... More
Supply, Installation, Testing, Commissioning and Programming of Dotnet Based Reporting Software with unlimited no of user configurable reports along with selection of time period, parameters, events, alarms complete with user defined Logo user name, date and time, page no., header and footer. Make: Net Solutions / Recktronic Devices and Systems / Revolution Info Systems

1

-

-

... More
Supply, Installing,Testing and Commissioning of Ultrasonic Level Transmitter at Pure Water Sump ( for measurement of level in Pure Water ) - including all accessories complete all as specified and directed. Range : 0-5 meters , Accuracy : 0.5 % minimum ,Supply Voltage : 24V dc,Output : 4-20 mA Make: BANNER/ NIVELCO / SIEMENS

24

-

-

... More
Supply, Installation, Testing and Commissioning of Pressure Switch along with all necessary installation accessories like GI barrel piece, double nipple etc. having range 0-6 sq cm. With Weather proof enclosure complete all as specified and directed. Make: DANFOSS / SWITZER / SIEMENS

60

-

-

... More
Supplying , laying / fixing on wall/ panel/ in trench 1100 Volt grade 2 x 1.5 sq.mm. PVC insulated and PVC sheathedarmoured copper conductor cable etc as reqd for following size complete all as specified and directed. Note- Excavation and earth work shall be measured and paid seperatelly. Make: Finolex/Polycab/Havells

900

-

-

... More
Supplying , laying / fixing on wall/ panel/ in trench 1100 Volt grade 4 x 1.5 sq.mm. PVC insulated and PVC sheathedarmoured copper conductor cable etc as reqd for following size complete all as specified and directed. Note- Excavation and earth work shall be measured and paid seperatelly. Make: Finolex/Polycab/Havells

3000

-

-

... More
Supply and laying old size brick covering with width equal to length of brick as the mechanical protection to cable with well burnt sub class 'B' laid in trenches flat complete all as specified and directed by Engineer-in-Charge

4100

-

-

... More
SCHEDULE 'A' PART-XIII (DG SET)

-

-

-

... More
Supply, installation, testing and commissioning of econ friendly silent disel engine driven generating set super silent DG set AC to give an output of 125 KVA at 415 Volts, 3 phase 50 cycle per second 4 wire 0.8 power factor or nearest higher size complete with disel engine water cooled mounted on a common base plate with floor mounted and fuel tank including earth work in PCC foundation with vibration pads and other accessories including AMF panel, Make - Kirloskar Green / Mahindra & Mahindra / Greaves Cotton, coprising of the following :-

2

-

-

... More
A. ENGINE : Diesel driven water cooled 1500 RPM suitable alternator 125 KVA under NTP condation with 10% over loading for 1 hour in 12 hour running. i) Fly wheel to suit coupling ii) Flexible coupling with guard bolt and nuts iii) Oil type air cleaner iv) Radiator with guard and fins and radiator fan v) Fuel pump complete with fuel injectors (FIP) vi) Governor vii) Fuel filter viii) Lubrication Oil filter ix) self starter x) Exhaust silencer with pipe xi) Intrumental panel complete with the following:- a) Self starting key and switch b) Lubricating oil pressure guage c) Battery charging alternator d) Hours meter and Ampere meter e) Temperature guage

-

-

-

... More
B. ALTERNATOR :- It shall be self excited, self regulted, balanced type for 415 Volts , 3 phase, 50 Hz,125 KVA or nearest in higher size 1500 RPM star connected 4 wire drip proof screw protected self ventilated enclosure as 4722 with drip proof enclosure with damper winding on pole faces, static automatic and hand voltage regulator to provide regulation + - 2.5% from no load to full load power factor and insulation as per standard practic. Make - Kirloskar Green / Mahindra & Mahindra / Greaves Cotton.

-

-

-

... More
C. LT CONTROL PANEL :- Fabricated out of 3.15 mm CRCA sheet cubical type mounting in Acoustic enclosure with the following :- i) AC voltmeter (0-500 volts) with selector switch -1set ii) AC Amps meter (0-150 Amps) of suitable range CT opratethd with selector switch - 01 set iii) power factor meter - 01 Nos iv) Frequency meter -01 Nos v) Battery charger indicator meter -01 Nos vi) Indicating lamp -03 Nos vii) Aluminium bus bar 4 strips of 200 Amps capacity -01 set viii) MCCB 200 Amps 36 KA, 4 pole, 415 volts-01 Nos D. BATTERY :- Starting battery 12 Volts, 180 AH maintenance free with copper lead of suitable length withlugs -01 set and brass terminal placed on angle iron standred frame in wooden plat form of suitable size. Make- Exide / Amron E. BASE PLATE :- Base plate of MS chanel fabricated and welded duly ribbed suitable for mounting alternator along with coupling and tray.

-

-

-

... More
F. PCC :- PCC foundation shall be as per manufacturer drawing/design G. Battery charger set 12 volts suitable for charging of 01 Nos battery H. Supply and fixing including assembly the above DG set in high quality acoustic enclosure of suitable dimension as per manufacturers recomandation. The enclosure shall be designed on modern construction having surface treatment like degreasing, pickling,phosphate, passivation and power coating finished. The acoustic insulation shall be of high quality, high density capable of with standing a temperature of 450 degree centigrate. The temprature of insulation cabin shall be less then 5 degree centigrate. The enclosure shall be provided with the following :- i) High temp safety for enclosure ii) Access to fill fuel out side iii) Special lockable doors iv) Sheet steel component per treated with zinc phosphate prior to polyester power coating. v) Zink plated or stainless steel fasteners vi) EDPM quality gasket

-

-

-

... More
vii) Engine and alternator shall be mounted through AVM pads on a comman chanal iron fabricated base frame to rest gross waight of DG set unit. viii) Noise level of 76 Db (A) at 1 mtr distance controlled by providing specially designed to control the sound at air entry exist of the enclosure . ix) Manually operated semi rotary pump for filling diesel. Note :- (i) Operator for round the clock to run the DG set will be provided by the contractor under gurantee period of one year after copletion of work. Rate shall be quoted by the contractor accordingly. POL will be issued by the department to run the DG set after copletion of work. (ii) The components i.e engine, alternator, panel etc of all the DG sets shall be procured from the same OEM. ( One of the makes and OEM as specified here in before) (iii) The component of DG sets shall not be more then six months old at the time of procurement.

-

-

-

... More
(iv) Before delivery of DG set, the inspaction of the DG set shall be carried out at the workshop of the OEM by the rep of the Accepting officer, necessary arrangement for inspaction shall be done by the contractor. (v) Engine and alternator of same make shall be preferred in case both are being manufactured by the same manufacturer or alternator as recomanded to use by the manufacturer shall be allowed. No price adjustment on this account shall be made and No misunderstanding on this account shall be entertained at later. Contractor quoted rate shall be deemed to be included for this aspect.

-

-

-

... More
All as above herein before but 100 KVA

1

-

-

... More
All as above herein before but 10 KVA

6

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick, buired directly in ground ( earth pit not less then 2.25 meters deep below ground level) with using galvanised iron strip 32x6mm thick as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3, with top edge of the plate not less then 1.5 meters below normal ground level, surrounded from all sides by charcoal dust and common salt in alternative layers of 15cm depth and earth connected with equipment by means of bolts, nuts, check nuts and washers of galvanised iron and connection to earth mesh including welding and complete with fire charcoal after installing earth strip , earth work and filling pit with PCC 1:2:4 type B1 using 20mm graded stone aggregate as in pit chamber and RCC pit cover 50mm thick precast (1:1.5:3) reinforced with MS round bars 6mm dia @ 150c/c both ways and with 10mm dia MS bar in lifting handle complete all as specified and as directed.

57

-

-

... More
Material & Labour for brick masonry valve pit of internal size 150cm x150cm x 150cm with one brick thick wall using sub class ‘B’ brick in cement mortar 1:6 over 20cm thick PCC plate form with 15cm off sets on every side of 1:3:6 type C-1 including plastering of internal surfaces and exposed surfaces with 15mm thick plastering in cement mortar 1:4 and 50mm thick RCC cover (in two equal parts 1:2:4 type B-1 with 10mm dia deformed bars at 10cm interval on both side including necessary form work with 150mm dia hole in the center complete all as specified and as directed by Engineer-in-Charge

36

-

-

... More
SCHEDULE 'A' PART-XIV (MANNING & OPERATION AND COMPREHENSIVE MAIANTENANCE)

-

-

-

... More
Manning and operation of Sewage Treatment Plant System for12 months (After completion of Phase II) with one skilled FGM, one halper/unskilled in three shift of 08 hours each for each continious operation and for each STPs ( i.e Three STPs) shift of 08 hours each in a day (including sunday/holiday) to maintain with SCADA system including cleaning to complete permises, ensuring attending all repairs, breakdowns etc promptly with out delay, servicing and maintenance of plant as per PS, ensuring servicieability of SCADA once daily, involving own conveyance and communication system like mobile etc arrangement complete for STP plant with all minor consumable and expandable items and labour and tools for smooth and efficient operation all as specified and directed by Engr-in-Charge.

12

-

-

... More
Manning and operation of Sewage Treatment Plant System for 12 months (After completion of M&O as given in Item No 102 here in before) with one skilled FGM, one halper/unskilled in three shift of 08 hours each for each continious operation and for each STPs ( i.e Three STPs) shift of 08 hours each in a day (including sunday/holiday) to maintain with SCADA system including cleaning to complete permises, ensuring attending all repairs, breakdowns etc promptly with out delay, servicing and maintenance of plant as per PS, ensuring servicieability of SCADA once daily, involving own conveyance and communication system like mobile etc arrangement complete for STP plant with all minor consumable and expandable items and labour and tools for smooth and efficient operation all as specified and directed by Engr-in-Charge. Note for Item 102 & 103 (a) The shift timming will be as mentioned below :- (i) First Shift 000 hrs to 0800hrs. (ii) Second Shift 0800 hrs to 1600 hrs. (iii) Third Shift 1600 hrs to 2400 hrs. (b) Records of activity such as voltage/current/PF/energy consumed/ temperature of transformer, breakdown, day to day maintenance of solar PV plant etc. Log book and other consumable to be provided by contractor. (c) AThe contractor shall ensure thall all safety precautions are strictly exercised by the staff employed him. Adherance to IE rule and satutory rules in vogues must be ensured. The contractor shall be fully responsible for any mishap that occurs due to any fault of the employee or no adherance of safety norms. Her shell provide all shafty gear/pamplete/poster at all installation. (d) Three STP of capacity 0.5 MLD, 1.2 MLD & 3 MLD.

12

-

-

... More
Comprehensive maintenance of Sewage Treatment Plant System for12 months (After expiry of defect liability period) with all arrangements complete for STP plant with all minor consumable and expandable items and labour and tools for smooth and efficient operation all as specified and directed by Engr-in-Charge. NOTE :- Comprehensive maintenance of Sewage Treatment Plant of 12 months after completion of Phase II shall be deemed included in the unit rate quoted by the contractor as per condition 46 of IAFW-2249 i.e defect liability period. Further, Comprehensive maintenance of Sewage Treatment Plant of 12 months after completion of defect liability period shall be paid under Phase III. NOTE:-Tenderers may plaese note that amount of schedule of credit as given on Page No ____ shall be deducted at the time of acceptance of tender to arrive the contract sum.

12

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.