Military Engineer Services Tender

View complete overview of Uttarakhand MES Tender

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date18 Jun 2024
Closing Date22 Jul 2024
Tender Amount₹ 19,00,000 
Notes
Download

Costs

Summary

Repair/replacement Of Unserviceable Internal Wiring, Light Fittings, Comprehensive Maintenance Of External Water Supply System, Lt Over Head Lines, Ug Cable Including Other E/m Allied Works Against Maint Programme Of Rudraprayag, Gaucher Annarendra N

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No 2 above but one socket outlet 5 pin 5/6 Amps on same board with other one, one way switch.

20

-

-

... More
All as per item No 2 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 4 Sqmm for continuty earth wire connected to common earth dolly all as specified and directed.

12

-

-

... More
S&F in replacement switch piano flush type 5/6 Amps single pole one way incl taking out old unsv switch all as specified & directed. Make :Anchor/legrand/HPL

120

-

-

... More
S&F in replacement switch piano flush type 15/16 Amps single pole one way incl taking out old unsv switch all as specified & directed.Make : Anchor/legrand/HPL

12

-

-

... More
M&L in replacement socket out let 5 pin 5/6 Amps incl taking out old unsv socket all as specified and directed. Make : Anchor/legrand/HPL

40

-

-

... More
S&F in replacement socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps incl taking out old unsv socket all as specified and directed. Make : Anchor/legrand/HPL

12

-

-

... More
S&F in replacement bell push, flush type 5 Amps white or ivory, ISI marked incl taking out old unsv bell push all as specified and directed. Make : Anchor/legrand/HPL

2

-

-

... More
S&F in replacement of call bell Ding Dong 230V, AC, single phase ISI marked incl taking out old unsv call bell all as specified and directed. Make : Anchor/legrand/HPL

2

-

-

... More
S&F in replacement plug top 15 Amp white or ivory, ISI marked incl taking out old unsv top all as specified and directed. Make : Anchor/legrand/HPL

10

-

-

... More
S&F in replacement plug top 5 Amp white or ivory, ISI marked. incl taking out old unsv top Make : Anchor/legrand/HPL

12

-

-

... More
S&F in replacement ceiling rose 3 terminals 65x25 mm dia poly carbonate isolated incl taking out old unsv ceiling rose all as specified and directed. Make :SSK/Cona/Anchor

60

-

-

... More
S&F in replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings incl taking out old unsv holder Make : Anchor/legrand/HPL

30

-

-

... More
S&F in replacement stepped type electronic fan regulator flush incl taking out old unsv regulator all as specified and directed Make : Anchor/legrand/HPL

15

-

-

... More
S&F in replacement of 3 watt LED bulb. cool day light, 230/240V AC supply all as specified and directed. Make : Surya/philips/Bajaj

30

-

-

... More
S&F in replacement of 7 watt LED bulb. cool day light, 230/240V AC supply all as specified and directed. Make : Surya/philips/Bajaj

40

-

-

... More
S&F 9 watt LED bulb inverter (backup) type A19 shape with B22 base, 230 V, battery with minimum 4 hrs backup time, froasted diffuser, total system lumens 900 Lm (minimum) on supply and 400 Lm (Min) on battery, colour temp 6500k, cool day light, 230/240V AC supply all as specified and as directed. Make : Wipro/Havells/Surya/philips/Bajaj

10

-

-

... More
S&F in replacement of 9 watt LED bulb cool day light, 230/240V, AC supply all as specified and directed. Make : Surya/philips/Bajaj

100

-

-

... More
S & F in replacement LED light fitting 1x9W/ 1x10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and directed. Make Philips/CG/Bajaj

10

-

-

... More
S&F in repalcement LED tube light fitting 2 feet 10 watt slim elegant design, including provision of two round/square PVC boxes 2 cm in depth and including connected with 2/3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Make : CG/Philips/Bajaj

10

-

-

... More
Supply and fixing in replacement 5 watt 220 volts AC rconcealed with high efficiency PMMA diffuser soft glare free light square type of suitable site as per site requirement complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with two/three core flexible copper conductor cable of suitable size complete all as specified and directed.

6

-

-

... More
Supply and fixing in replacement 18 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light square type of suitable site as per site requirement complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with two/three core flexible copper conductor cable of suitable size complete all as specified and directed. Make : wipro/Philips/Bajaj

6

-

-

... More
S&F LED inverter batten fitting 1 x 18 watt including tube rod, min housing aluminium front cover PC, battery backup 3-4 hrs after fully charge, 230 V, system lumens efficiency 80 Lm/W, CRI 80, THD 30%, Driver efficiency 85%, bipin holders connector block etc complete with all accessories pre wired and provision of two round/square PVC boxes 2 cm in depth and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Make : Havells/Halonix/Crompton/Philips/Bajaj

15

-

-

... More
S&F in replacement LED tube light fitting bright 18 watt slim elegant design and provision of two round/square PVC boxes 2 cm in depth and including connected with 2 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Make : Crompton/Philips/Bajaj

122

-

-

... More
Supply and fixing in replacement round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with two/three core flexible copper conductor cable of suitable size complete all as specified and directed. Make : wipro/Philips/Bajaj/Havells

6

-

-

... More
Supply and fixing in replacement round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with two/three core flexible copper conductor cable of suitable size complete all as specified and directed. Make : wipro/Philips/Baja/Havells

4

-

-

... More
S&F in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. Make: Philips/Bajaj/wipro

2

-

-

... More
S&F in replacement of building security light fitting complete with 25 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed bracket made out by GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed Make:- philips/CG/ Bajaj/HPL

4

-

-

... More
Supply and fix in replacement of DB, SPN 4 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed Make:-Legrand/Schneider/HPL

2

-

-

... More
Supply and fix in replacement of DB, SPN 8 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed Make:-Legrand/Schneider/HPL

2

-

-

... More
Supply and fix in replacement of DB, SPN 12 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed Make:-Legrand/Schneider/HPL

1

-

-

... More
Supply and fix in replcement MCB 6-32 amps, 10 KA, SP 240 volt, 'B' series all as specified and directed Make:-Legrand/Schneider/ HPL

40

-

-

... More
Supply and fix in replcement MCB 32-40 amps, 10 KA, SPN 240 volt, 'B' series all as specified and directed Make:-Legrand/Schneider/ HPL

10

-

-

... More
All as per item No 36 hereinbefore but MCB SPN 63 amps. Make:-Legrand/Schneider/ HPL

2

-

-

... More
All as per item No 36 hereinbefore but MCB TP 63 amps. Make:-Legrand/Schneider/ HPL

1

-

-

... More
Taking down/dismantling of defective/rusted storage type hot water Geyser of 50/35/25 litre capacity from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts by unscrewing bolts and nuts, descaling/cleaning inner shell, servicing etc. checking defects, re-assembling and re-installing the Geyser in position, connection and testing all as specified & directed

20

-

-

... More
S&F in replacement PVC flexible pipes 15mm dia (heavy duty) both end socketed with washer 450 mm long for hot/cold water (ISI marked) all as specified & directed.

8

-

-

... More
S&F in replacement of PVC flexible pipes 15mm dia (heavy duty) both end socketed with washer 600 mm long for hot/cold water (ISI marked) all as specified & directed.

8

-

-

... More
Supply and fix in replacement of stop valve fancy type cast copper alloy screwed down high pressure with crutch or butter fly handle, chromium plated screwed both ends of size 15 mm bore, for geyser connection all as specified and directed. Make : Leader/Kirloskar/L&T/Prayag/ TATA

4

-

-

... More
S&F in replacement of inner tank 6/9 holes suitable for Geyser 25 liters capacity incl Apparatus assembly made of copper Make : Usha/Lexus/Crompton

1

-

-

... More
S&F in replacement of inner tank 6/9 holes suitable for Geyser 35 litres capacity incl Apparatus assembly made of copper Make : Usha/Lexus/Crompton

1

-

-

... More
S&F in replacement of Inner tank 6/9 holes suitable for Geyser 50 litres capacity incl Apparatus assembly made of copper Make : Usha/Lexus/Crompton

1

-

-

... More
S&F in replacement of indication lamp (Green/Red) as per required at site all as specified & directed.

10

-

-

... More
S&F in replacement of thermal Auto cut of range 0-90 degree centigrade (ISI marked) complete all as specified and directed.

12

-

-

... More
S&F in replacement of geyser heating element 1.5 KW (ISI marked) round type/thread/triangle base type with the provision of thermal cut out all as specified and directed.

8

-

-

... More
S&F in replacement of geyser heating element 2 KW (ISI marked) round/thread/triangle base type with the provision of thermal cut out all as specified and directed.

4

-

-

... More
S&F in replacement of circular ring gasket for geyser assembly 6/9 holes as per site requirement (ISI Marked) all as specified & directed

5

-

-

... More
S&F in replacement of bottom plate as per existing size (ISI Marked) all as specified and directed

5

-

-

... More
S&F in replacement of Geyser assembly suitable for 25/35/50 litres geyser capacity (ISI Marked) complete all as specified and directed

2

-

-

... More
Taking down carefully unserviceable exhaust fans of any size from its position, dismanteling blades, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condensor, condensor holder, shackle, reassembling after replacement of defective parts including replacements of 3 core, 0.75sqmm (24/0.2mm) flexible copper cable from ceiling rose to connector, hanging on its position properly all as specified and directed. Note :- Defective parts like ball bearing, bush bearing and motor rewinding, shaft, condensor, rubber shackle will be measured and paid separately

5

-

-

... More
S&F in replacement of ball /bush bearing suitable for exhaust fan of same size as that of existing defective one (ISI Marked) all as specified and directed Make : SKF/TATA/Universal/polar

5

-

-

... More
Supply only condenser capacity 4 MFD/ 3.15 MFD/ 2 MFD all as specified and directed. Make : Usha/Universal/ Keltran

50

-

-

... More
Cleaning and preparing the surfaces of exhaust fan any size, removing the grease, carbon dust over the fans and painting with two coats of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan all as specified and directed.

5

-

-

... More
M&L for burnt out rewinding exhaust fan with super enamelled bare copper conductor with the same size and number of turns as that of the old one, insulating, varnishing and pre heating for the 280 to 450 mm sweep all as specified and directed.

6

-

-

... More
S&F in replecement of blade suitable for exhaust fan 300/450mm, size as that of existing defective one all as specified and directed. (ISI Marked)

2

-

-

... More
Taking down carefully unserviceable ceiling fans of 1200/1400mm sweep from its position, dismanteling blades, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condensor, condensor holder, shackle, reassembling after replacement of defective parts including replacements of 3 core, 0.75sqmm (24/0.2mm) flexible copper cable from ceiling rose to connector, hanging on its position properly all as specified and directed. Note :- motor rewinding and condensor will be measured and paid separately.

50

-

-

... More
M&L for rewinding ceiling fan with super enamelled bare copper conductor with the same size and number of turns as that of the old one, insulating, varnishing and pre heating for the 1200/1400 mm sweep including suitable size of bearings all as specified and directed.

24

-

-

... More
Taking down carefully unserviceable Wall mounted fans of any size from its position, dismanteling blades, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condensor, condensor holder, shackle, reassembling after replacement of defective parts including replacements of 3 core, 0.75sqmm (24/0.2mm) flexible copper cable from ceiling rose to connector, hanging on its position properly all as specified and directed. Note :- Only rewinding of fan will be measured and paid seperately.

6

-

-

... More
M&L for rewinding Wall fan with super enamelled bare copper conductor with the same size and number of turns as that of the old one, insulating, varnishing and pre heating for the 400/450 mm sweep including suitable size of bearings all as specified and directed.

6

-

-

... More
Dismentaling and taking out old existing unserviceable GI pipe of size 80 mm dia from trenches/ under floor, roads, paths or from walls/poles/ducts all as specified and directed

162

-

-

... More
All as per Item No 62 here-in-before but of size 50 mm bore

60

-

-

... More
All as per Item No 62 here-in-before but of size 40 mm bore

60

-

-

... More
All as per Item No 62 here-in-before but of size 25 mm bore

80

-

-

... More
All as per Item No 62 here-in-before but of size 20 mm bore

80

-

-

... More
S&F 80 mm bore GI tubing medium grade with all fittings, laid in trenches, duly welded, nuts & bolts gaskets and all accesories including union, nipple, socket, elbow or reducer etc required for completion of work all as specified and directed. Make : Jindal/Tata/Prakash Surya. (Note:- Rate for carring of Generator,Weding Machine and transportation cost for pipes at source deemed incuded in item rate. Excavation & earth work shall be measured and paid for separately under respective item of this schedule)

162

-

-

... More
S&F 50 mm bore GI tubing medium grade with all fittings, laid in trenches, duly welded, nuts & bolts gaskets and all accesories including union, nipple, socket, elbow or reducer etc required for completion of work all as specified and directed. Make : Jindal/Tata/Prakash Surya.

60

-

-

... More
All as per Item No 68 here-in-before but of size 40 mm bore

60

-

-

... More
All as per Item No 68 here-in-before but of size 25 mm bore

60

-

-

... More
All as per Item No 68 here-in-before but of size 20 mm bore

80

-

-

... More
Dismentaling and taking out old existing unserviceable GI pipe of size 80 mm dia from trenches/ under floor, roads, paths and relaying duly welded, nuts & bolts gaskets and all accesories including union, nipple, socket, elbow or reducer etc required for completion of work all as specified and directed. (Note:- Rate for carring of Generator,Weding Machine and transportation cost for pipes at source deemed incuded in item rate. Excavation & earth work shall be measured and paid for separately under respective item of this schedule)

162

-

-

... More
Dismantling/taking out of old U/s gate valve and supply and fixing Gun metal gate valve/glove valve ISI marked with Iron wheel head screwed both end for GI tubing of following sizes :- Make : Zoloto/Leader/L&T/Kirloskar

-

-

-

... More
All as per Item No 73 here-in-before but of size 25 mm bore

6

-

-

... More
All as per Item No 73 here-in-before but of size 40 mm bore

2

-

-

... More
All as per Item No 73 here-in-before but of size 50 mm bore

2

-

-

... More
M&L for cleaning of (20000 ltr sand filter tank ) filling the following filter media in the filter bed duly cleaned and washed with 5% concentrated solution of NaOH complete including clening of tank as per standard procedure all as directed by Engr-in charge (a) Filter gravels (pebbles) 1.5'' -2'' -1.4 Cum (b) -do- but size 3/41.5'' -0.9 Cum (c ) -do- but size 1/2''-3/4'' - 0.3 Cum (d) -do- but size 1/4'' - 3/8'' -0.3 Cum (e) -do- but size 1/8'' - 1/4'' - 0.5 Cun (f) Fine sand of size 1/32'' -1/16'' -5 Cum

1

-

-

... More
M&L in replacement of 3mm thick MS sheet top cover over the sluice valve pit/filtration tank, made with MS angle iron/channel and MS sheet with locking arrangement incl pad lock andproviding suitable lifting handle for each voer/valve pit including cutting, drilling, bending etc complete all as specified at site

1.2

-

-

... More
M&L in replacement of Gun metal globe or gate valves, with iron wheel head , screwed both ends for iron pipes of size 80 mm dia with washers ,all as specified and directed.Make : Kirloskar/leader/Kartar.

1

-

-

... More
Supply and install of cast iron sluice valve of size 80 mm bore class-I PN-1:6 with gun metal spindle both end flanged complete with all fitting all as specified and directed by Engr in Charge. Make : Kirloskar/leader/Kartar.

2

-

-

... More
M&L for cleaning of complete water tank of 10000 to 25,000 gln capacity with chamber complete as specified and directed by Engr-in-Charge, comprising the following works :- (a) Dewatering of left out water from the tank manually or by pumping out throgh pump set (b) Taking out complete sludge/mud from the tank and removing/storing the same at low level are ermarked by Engr-in-Charge within 50 m radius (c ) Cleaning inner surface of wall and bottom of tank with the help of wire brushes, scrapper and broom for cleaning of sludge from walls/floors (d) Washing of inner walls of tank by bleaching powder solutiion (e) Repairing of unserviceable angle/MS Sheet of sedimentation tank with welding work where necessary complete all as per site requirement (f) The empty sedimentation tank shall be first cleaned with fresh water twice and ther after cleaned with fresh water sterililsed with 2% solution of potassium permagnate and writing location, capacity and date of cleaning with white paint firm and hand written over a black plate with synthetic enamel paint etc complete for entire satisfaction of Engr-in-Charge

2

-

-

... More
S&F in replacement of galvanised iron flange on existing pipe of 80mm bore (02 Nos in each pipe) with nuts, bolts and washers complete all as specified and directed.

3

-

-

... More
Testing of water for chemical test and bacterial test complete report in respect of water sample of Rudraprayag station from IIT Roorkee or any Govt approved laboratory

1

-

-

... More
Taking out worn winding of Submersible pump motor startor of capacity 5 HP carefully and rewinding the same with existing size of super enamelled copper winding wire ,including necessary varnishing and insulating material baking etc, transportation to workshop and back at site complete all as directed by Engineer-in-Charge.

1

-

-

... More
Supply and fixing in replacement of starter for Submersible motor pump with single phase preventer of capacity 5 HP at site complete all as directed by Engineer-in-Charge Make : L&T, Crompton,Kirloskar

1

-

-

... More
M&L for complete service of compresssor incl changing of oil servicing of motor and replacement of 2 Nos belts all as specified and as directed by engr incharge

1

-

-

... More
M&L for High density polyethylene pipes(HDPE) 90mm size of pressurerating 6 kgf/cm2 laidin trenches all as specified and directed

30

-

-

... More
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable, Pipe, Manhole and Sewage line n. exc 10 sqm on plan and nexc 1.5m in depth and getting out in any type of soil complete all as specified and directed.

103.5

-

-

... More
Excavation in trenches n. exc. 1.5 mtr in wide but exc. 1.5 mtr in depth for laying of underground cable and getting out in any type of soil complete all as specified and directed.

0.11

-

-

... More
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed

92.61

-

-

... More
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.

12

-

-

... More
Supply and fix in replacement, laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 95 sqmm 3.5 core all as per IS , specified & directed. Make of under mantion XLPE cable : Havells/Polycab/Finolex/Universal

30

-

-

... More
Supply and fix in replacement, laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 50 sqmm 3.5 core all as per IS , specified & directed. Make of under mantion XLPE cable : Havells/Polycab/Finolex/Universal

130

-

-

... More
Supply, laying, jointing and testing in replacement of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 16 sqmm 4 core all as per IS , specified & directed.

150

-

-

... More
Supply, laying, jointing and testing in replacement of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 10 sqmm 2 core all as per IS , specified & directed.

280

-

-

... More
Material and labour for lying DWC( double wall corrugatd) pipe confirming to IS 16205 (electric cable use) of nominal outer dia 50 mm and inner dia 38 mm for lying electrical cables under trenches/under road/wall complete all as specified and directed Make : Universal/Rax or Equivalent

350

-

-

... More
Material and labour for lying DWC( double wall corrugatd) pipe confirming to IS 16205 (electric cable use) of nominal outer dia 90 mm and inner dia 75 mm for lying electrical cables under trenches/under road/wall complete all as specified and directed Make : Universal/Rax or Equivalent

110

-

-

... More
Material and labour for lying DWC( double wall corrugatd) pipe confirming to IS 16205 (electric cable use) of nominal outer dia 110 mm and inner dia 95 mm for lying electrical cables under trenches/under road/wall complete all as specified and directed Make : Universal/Rax or Equivalent

20

-

-

... More
Supply and fixing LED Street light fittings 45watt 230V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver , lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection type complete all as specified and directed.

16

-

-

... More
Supply and fix in replacement of bracket made out of GI tubing single piece not welded bended at proper angle of size 40mm dia, light grade 1.5 mtr long including painting with aluminium paint over one coat of red oxide to the bracket etc complete. including 1.0 sqmm 3.0 core flexible Copper cable in PVC conduit with clamp from junction box to connecter of street light fitting.

10

-

-

... More
Supply, fixing in replacement, connecting and testing of MCCBs in existing LT panel box / feeder pillar boxes of capacity 160 Amps 4 pole breaking capacity 25 KA with thermal as well as magnetic balance adjustable type complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement MCCB 4P , 25 KA , 100 Amp fixed thermal and magnetic settings , ICS=75% ICU complete all as specified and directed.

2

-

-

... More
Supply and fix in replacement MCCB 4P , 16 KA , 63 Amp, fixed thermal and magnetic settings , ICS=75% ICU complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement MCCB 4P , 16 KA , 40 Amp fixed thermal and magnetic settings , ICS=75% ICU complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacement LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Make: Bajaj/CG/Havells.

2

-

-

... More
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. Make: Bajaj/CG/Havells.

4

-

-

... More
S&F, errecting in replacement of steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type/size complete all as specified and directed. Make : India Co. Ltd Jamshedpur/Fabrico(India) Pvt Ltd Meerut/National Tubing Co. Kanpur Note: Earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.

2

-

-

... More
M&L for PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.

5

-

-

... More
M&L for PCC 1:2:4 Type B-1 using 20 mm graded aggregate for coping of poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site.

0.19

-

-

... More
M&L in replacement for earthing complete with using galvanized mild steel earth plate (electrode) 600 mm x 600 mm x 6.30 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 32X6 mm GI earth strip as earth lead moulded and riveted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead incased in and including 50 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone agg)duly reinforced with mild steel round bars 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handles with and including necessary excavation & earth work including laying the GI pipe concealed in floor /wall all as per plate No. 3 of SSR Part I complete all as specified and directed and testing on completion..NOTE :- GI earth wire and protection pipe beyond 7.5 mtr will be measured and paid separately. (Note : 1. If the desired earth resistance is not found earthing shall be re-done by the Contractor at no extra cost paid by Dept.)

3

-

-

... More
Supply and fix in replacement of pole box size 300 x 200 x 150 mm fabricated out of 2 mm thick MS Sheet having 4 Nos aluminium busbar of suitable size with 1 No. MCB SP 6 Amps front openable hinged cover outdoor type weather proof suitable for mounting on steel pole including fixing MS clamp 02 Nos with nuts, bolts and washers complete all as specified and directed. Make : HPL/ C&S/ Gaurav

10

-

-

... More
M& L in replacement cross arms, bracings, supports, clamps (including stay clamps, clamps for fixing GI tubes for passing through of cables) and back plates fabricated out of standard steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size incl welding work as directed and inclusive of providing two coats of aluminium paint over a coat of primer after preparation of steel surfaces complete all as specified and directed,

0.5

-

-

... More
Supply and fix in replacement of out door type busbar chamber of size 50xz50x30 cm (Feeder piller box) fabricated by MS sheet of size 3.14 mm gauge mounting on angle iron frame suitable for 415 Volts, 3 phase, 4 wire AC as specified and including aluminium bus bar of capcity 200 amp installed on porcelain insulators. The Busbar Chambers shall be dust proof, vermin proof and 40 x 40 x6 mm angle iron frame work, front opening with locking arrangement duly painted with two coats of grey enamel paint over a coat of red oxide primer on the outside and two coats of red oxide primer in the inside all as specified and directed. Make : HPL/Gaurav/Shalabh Pvt Ltd/C&S(CPRI approved)

1

-

-

... More
Supply and replacement in repair of broken earth pit of size 350x350x350 mm made of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, 20 mm and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia TMT bars @ 100 mm centre to centre both ways with handle made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site with testing result. complete all as specified and directed.

6

-

-

... More
S&F new generation energy saving environmental friendly long life aesthetically designed aluminium landscape luminare for diffused lighting with high power LED Bollard with opal acrylic diffuser and IP 65 protection as light source all as specified and directed. MAKE : Bajaj / Havells/ Crompton

10

-

-

... More
Supply and fix in replacement of Decorative LED 15 watt new generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source and including connected with 3 core

2

-

-

... More
M & L for Painting to poles (9/11 mtr long) including cross arms, 'V' brackets, 'D' clamps, nuts, bolts, complete including painting with five strips of 30cm each black and white paint in alternate strips from the base of pole upto 1.5mtr height complete, spray painting with two coat of synthetic enamel paint of first quality silver paint over a coat of red oxide primer after and including complete removal of old paint by scratching, rubbing complete all as specified and directed

28

-

-

... More
Demolition of cement concrete in ground floor and paving n exc 15 cm thickness ( below or above ground level) etc complete all as specified and directed.

3

-

-

... More
Demolition of Concrete unreinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed

0.6

-

-

... More
Demolition for reinforced Concrete of any description and in any position not otherwise specifically provided for cement concrete complete all as specified and directed.

1

-

-

... More
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.

5

-

-

... More
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, including ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.

11

-

-

... More
Taking down cement plaster of any description on stone walls incl raking joints, hacking for key, scrubbing down with water etc complete all as specified and directed.

30

-

-

... More
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed..

0.25

-

-

... More
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out portion embedded in concrete and making good disturbed ground complete all as specified and directed.

10

-

-

... More
Dismantling of 150 mm dia CI pipes pipe jointed in cement mortar and taking out of trenches if required complete all as specified and directed.

7

-

-

... More
Dismantling of 100 mm dia CI pipes pipe jointed in cement mortar and taking out of trenches if required complete all as specified and directed.

11

-

-

... More
Demolition and breaking up 150mm dia drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.

5

-

-

... More
M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete etc complete all as specified and directed.

6

-

-

... More
M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in coping including form work complete all as specified and directed.

0.25

-

-

... More
M&L for Providing precast cement concrete type 1:2:4 type B-1, (20 mm graded aggregate) as in landing, cover slab (for manholes etc) chullah woods, chajjas, water trough mangers, shelves, and similar articles with plain faces complete all as specified and directed.

1

-

-

... More
M&L for Non skid ceramic coloured tiles (300x300)x7 mm thick in floors etc. Set and jointed in neat cemenbt slurry and pointed in white or coloured cement to match and including over screed bed or bedding layer of mortar 15 mm thick laying floor finished in cement mortar 1:6 complete all as specifed and directed.

5

-

-

... More
M&L for Prepolished Chequered cement concrete tiles 25cm x 25cm/ 30cmx30 cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over and including 20 mm thick screed bed or bedding of CM 1:6 complete all as specified and directed

25

-

-

... More
M&L PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in surface channel and drain complete all as specified and directed.

0.6

-

-

... More
Extra for forming fair finished drain and channel 30 cm inner grith in cement concrete using extra cement in forms mould mitred/stopped ends complete all as specified and directed.

20

-

-

... More
Add or deduct for Items no 135 here in before for each 25 mm girth or part thereof over or under 30 cm complete all as specified and directed.

20

-

-

... More
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in concrete bed to 150 mm dia pipes including packing under and haunching against the side of pipes after they are laid and tested complete all as specified and directed.

7

-

-

... More
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in concrete bed to 100 mm dia pipes including packing under and haunching against the side of pipes after they are laid and tested complete all as specified and directed.

9

-

-

... More
M&L for pre cast cement concrete 1:3:6 type C1(using 20mm graded stone aggregate) solid block masonary exceeding 10cm thick and set in cement mortar 1:6 complete all as specified and directed..

5

-

-

... More
Description all as per Srl item No.139 here in before but except PCC bolcks

0.5

-

-

... More
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.

5

-

-

... More
Description all as per Srl item No.142 here in before but except stones

0.5

-

-

... More
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses with maximum depression on face from straight edge held against the dressed surface n exc 20 mm complete all as specified and directed.

10

-

-

... More
M&L for raised pointing to random or polygonal rubble, uncoursed or brought upto courses with CM 1:4 complete all as specified and directed.

2

-

-

... More
M&L for hand packing (any thickness) at back of walls etc with broken stone or boulder and raising (or lowring) to the required level complete all as specified and directed.

2.5

-

-

... More
M&L for rendering 15 mm thick in CM 1:4 on brick or concrete surface finished even and smooth without using extra cement complete all as specified and directed.

70

-

-

... More
M&L for preparing newly plastered wall surfaces and applying three coats of white wash complete all as specified and directed..

40

-

-

... More
M&L for 150 mm dia CI pipe (sand cast) soil waste and vent pipes in any length with or without ears with cement joints laid in trenches or in floors complete all as specified.

5

-

-

... More
.-Ditto- All as per item No 148 above but except pipe complete all as specified.

2

-

-

... More
M&L for 100 mm dia CI pipe (sand cast) soil waste and vent pipes in any length with or without ears with cement joints laid in trenches or in floors complete all as specified and directed.

8

-

-

... More
.-Ditto- All as per item No 150 above but except pipe complete all as specified and directed.

3

-

-

... More
S&F 150mm dia Reinforced concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and directed.

5

-

-

... More
S&F in repair 110mm bore PVC (SWR) pipe single socketed any length with rubber ring joints laid in trenches or in floor including taking down complete all as specified and directed.

5

-

-

... More
S&F in repair 75 mm bore PVC (SWR) pipe single socketed any length with rubber ring joints laid in trenches or in floor including taking down complete all as specified and directed.

5

-

-

... More
S&F for PVC (SWR) bends any radius 110mm bore pipe including taking down complete all as specified and directed.

2

-

-

... More
S&F in repair for 75mm PVC(SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.

2

-

-

... More
S&F for PVC (SWR) 'P’ trap of 110mm bore including taking down complete all as specified and directed.

2

-

-

... More
S&F for PVC (SWR) 'S’ trap of 110mm bore including taking down complete all as specified and directed.

2

-

-

... More
S&Fin repair vitreous china squatting pan 'Orissa' pattern size 580x440mm with white integral footrest (excluding flushing cistern and flush pipe including making good )complete all as specifed and directed.

2

-

-

... More
S&F in repair vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolt, flushing cistern and flush pipe) including making good complete all as specifed and directed.

1

-

-

... More
M&L for deformed/twisted MS bars 6 to 8mm dia, cut to length, bent to shape required including crancking bending spirally for hoping for col hooking ends and binding with and including mile steel wire non less than 0.9 mm dia securing with clips in quality complete all as specified and directed.

90

-

-

... More
Taking out of water from septic tank by pumping/manually in foul position as spd and removing to out side MD land complete all as specified and directed.

40

-

-

... More
Removing of sludge mixed with water n exc 150 m and depositing where directed at a level n exc 1.5 m above the starting point and burried in ground by digging, including RFR working in foul position complete all as specified and directed.

10

-

-

... More
Cleaning of existing sewage lines of any size by rodding with split bamboo or any other means as approved and removal of blockage including taking out existing RCC cover slabs of manholes of any size without damaging the slab covers to facilitate cleaning and replacing back in original position & cleaning debris/sludge in pipe line of any type complete all as directed by the Engineer-in-charge

200

-

-

... More
Cleaning of manhole of any size of removing of sludge mixed with water n exc 50 M away from the point complete all as specified and directed.

100

-

-

... More
Material and labour for cleaning of blockage manually by rodding, pumping, etc and removing the deposited sludge/solid/liquid material, outside MD land, complete all as directed for Water Closet (Indian or European) , trap & CI pipe line upto first manhole complete all as specified and directed.

20

-

-

... More
Ditto as per item No 166 here-in-before but for Floor/Nahni trap of Kitchen/Bathroom upto gully trap (excluding gully trap).

20

-

-

... More
Ditto as per item No 166 here-in-before but for Gully trap upto first manhole.

20

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.