Eprocure
Opening Date7 Sep 2024
Closing Date4 Oct 2024
Tender Amount₹ 8,00,000 
Notes
Download

Costs

Summary

Repair And Replacement Of External Water Supply Pipe Line, Valves, Pumps, Motors, Starters, Fire Fighting Equipments, Day To Day Complaints And Other Misc E/m Works At Diber Haldwani

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking out & removing old burnt out windings wire of the submersible electric motors of 5 to 7.5 HP, Three phase, 415 Volts, 50 Hz, AC supply capacity and rewinding of submersible electric motors with existing size PVC insulated, copper conductor wire including cleaning the slots with carbon- tetra-chloride solution before rewinding ,transportation to site complete all as specified and directed Notes : (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates. (ii) The windings of motor including windings wire and connected material is deemed to be included in the quoted rates

1

-

-

... More
Supply only Gun metal bush

1

-

-

... More
Supply only Thurst plate

1

-

-

... More
Supply only Shaft Grinding and polishing

1

-

-

... More
Dismantalling of submersible pumpset of capacity 5 to 7.5 HP cleaning and inspection of parts removal all defective parts & replacement of defective impellers, bushes, shaft, locking pin and non return valve,rematling and repairing of repairable item reassembling testing and commissioning all as directed by eng in charge. Notes : Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the quoted rates.

2

-

-

... More
Supply only Impeller

10

-

-

... More
Supply only Difuser

2

-

-

... More
Supply only Gunmetal bushes

2

-

-

... More
Supply only Coupler for motor and pump

1

-

-

... More
Supply only Non return valve

1

-

-

... More
Lowering down of the submersible pump set of any description and any capacity & in any position, in bore well alongwith column pipe 50 mm dia and submersible cable of any size (approximately 150 Mtr depth of pump set from GL) including making necessary electric connections and providing water tight cable joint & testing the pump set after lowering complete all as specified and directed (including notes mentioned here in below) NOTES :- 1. Contractor shall take proper precautions while lowering pump set in bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lowering of pump set etc shall be arranged by the contractor at his own cost. 2. Rates quoted by the contractor for the above item includes the cost of assembling & connecting pump set to column pipes & assembling, jointing and fixing column pipes with MS internally threaded flange welded with column pipe by using 04 Nos 20x3mm MS strips and thereafter jointed with rubber gasket joints and nuts, bolts / pump set at the end / submersible cable and making necessary connections and testing including reconnecting water supply system. The required materials like column pipe /flanges with rubber gasket joints/ submersible cable/ repaired pump sets etc shall be met out with old retrieved materials and additional quantity of column pipe, flanges with rubber gasket joints , submersible cable & straight through joint of cable shall be measured and paid for separately under respective item of this Schedule as “Supply only”, but the rate for its fixing shall be deemed to be included under this item.

1

-

-

... More
Supply and connecting of 4 Sqmm, 3 Core, flat submersible Cable, PVC insulated, PVC sheathed with multi-stranded copper conductors, conforming to IS : 694- 1990 of 1100 Volt grade, dismantled/fixed under Sch ‘A’ item No. 1 here in above complete all as specified and directed .

60

-

-

... More
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for taking out/for laying under ground cables/pipes etc and getting out any type soil all as dircted

35

-

-

... More
Returning filling in including spreading, levelling, watering and well ramming in layers n-exc 25 cm

21

-

-

... More
Removing excavated soil to a distance n-exc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point

10

-

-

... More
Supply and laying common burnt clay building bricks sub class "B" designation 75 old size bricks for cable protection

1200

-

-

... More
Supply and spreading fine river sand in trenches for cushioning of under ground cable/filling cable ducts all as directed by Engr-in-Charge at site Note : - Only punned thickness shall be measured for payment purpose

4

-

-

... More
Disconnecting and taking up or down old existing GI tubing and connections 20 mm bore, including connected fittings/accessories and fixtures of any description/ grade and in any position in trenches/under floors/road / on walls etc and making good the disturbed surface complete all as specified and directed

40

-

-

... More
All as per item No 21 but of size 25 mm bore

70

-

-

... More
All as per item No 21 but of size 40 mm bore

70

-

-

... More
All as per item No 21 but of size 50 mm bore

60

-

-

... More
Supply, fixing, laying, jointing & testing 20 mm bore of galvanised iron water tubing 'medium grade' conforming to IS-1239 with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc as required complete fixed checknuts, caps, plugs etc as required complete fixed to walls and ceilings, laid in trenches/under floor/under road or floors complete all as specified and directed

40

-

-

... More
All as per item No 25 but of size 25 mm bore

70

-

-

... More
All as per item No 25 but of size 40 mm bore

70

-

-

... More
All as per item No 25 but of size 50 mm bore

60

-

-

... More
Refixing old steel tubbing 20 mm bore and connection in new or old position in (trenches,wall, ceilling, floor,road etc) complete all as specified and directed

12

-

-

... More
All as per item No 29 but of size 25 mm bore

20

-

-

... More
All as per item No 29 but of size 40 mm bore

12

-

-

... More
All as per item No 29 but of size 50 mm bore

20

-

-

... More
M&L for cement concrete type D2 1:4:8 using 40 mm graded aggregate for making good surfaces in road cutting, pole foundation, stay concrete etc all as directed

2

-

-

... More
M&L for cutting out concrete blocks, slabs, brick work or stone masonary(in alternative course) Road pavement, forming, toothings for and bonding new work in mortar into old work, including new materials entering old wall set in cement mortor 1:6 with pre cast cement concrete type B1, 1:2:4 (20 mm graded aggregate) all as directed and specified.

2

-

-

... More
Disconneting the water supply to existing over head tank of capacity exc 1000 & n exc 2000 litres , washing , cleaning and removing scales, silt or dirt from the tank and refixing the same in position including washing internal surface of tank with the help of bleaching powder etc complete all as specified and directed

2

-

-

... More
Disconneting the water supply to existing over head tank of capacity exc 500 & n exc 1000 litres , washing , cleaning and removing scales, silt or dirt from the tank and refixing the same in position including washing internal surface of tank with the help of bleaching powder etc complete all as specified and directed

10

-

-

... More
Disconneting the water supply to existing over head tank of capacity exc 250 & n exc 500 litres , washing , cleaning and removing scales, silt or dirt from the tank and refixing the same in position including washing internal surface of tank with the help of bleaching powder etc complete all as specified and directed

30

-

-

... More
M&L for servicing/overhauling/repairing of existing defective centrifugal pump of following capacity 60 HP, 3 Phase,415 volts, AC supply and cleaning, oiling/greasing, fixing of serviceable parts in position, oiling/greasing,refixing of serviceable parts in position,balancing, realignment etcreplcement of nut bolt washer where required, welding braging and trasportation to workshop if required, Repair to bearing housing with metling and turning and fixing the same in position and testing on full load complete all as specified and directed. Booster/centrifugal pump of capacity 60 HP (i) Replacement of unserviceable parts if required shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates.

2

-

-

... More
All as per item No 38 but booster/centrifugal pump of capacity 25 HP,

2

-

-

... More
All as per item No 38 but booster/centrifugal pump of capacity 7.5HP,

2

-

-

... More
All as per item No 38 but booster/monoblock/centrifugal pump of capacity 4 to 5 HP,

4

-

-

... More
All as per item No 38 but booster/centrifugal/monoblock pump of capacity 2 to 3 HP,

5

-

-

... More
All as per item No 38 but booster/centrifugal/monoblock pump of capacity 1 HP,

4

-

-

... More
Taking out & removing old burnt out windings wire of the booster pump / centrifugal pump/ vertical pump electric motors of 5 to 7.5 HP, Three phase, 415 Volts, 50 Hz, AC supply including cleaning the slots with carbon- tetra-chloride solution before rewinding and rewinding of electric motors with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc and any trasportation to workshop if required,and fixing the same in position and testing on full load complete all as specified and directed. Notes : (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates. (ii) The windings of motor including windings wire and connected material is deemed to be included in the quoted rates

1

-

-

... More
Taking out & removing old burnt out windings wire of the booster pump / centrifugal pump/ vertical pump electric motors of 3 to 4 HP, Three phase, 415 Volts, 50 Hz, AC supply including cleaning the slots with carbon- tetra-chloride solution before rewinding and rewinding of electric motors with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc and any trasportation to workshop if required,and fixing the same in position and testing on full load complete all as specified and directed. Notes : (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates. (ii) The windings of motor including windings wire and connected material is deemed to be included in the quoted rates

1

-

-

... More
Taking out & removing old burnt out windings wire of the booster pump / centrifugal pump/ vertical pump electric motors of 1 to 2 HP, Three phase, 415 Volts, 50 Hz, AC supply including cleaning the slots with carbon- tetra-chloride solution before rewinding and rewinding of electric motors with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc and any trasportation to workshop if required,and fixing the same in position and testing on full load complete all as specified and directed. Notes : (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the quoted rates. (ii) The windings of motor including windings wire and connected material is deemed to be included in the quoted rates

1

-

-

... More
Supply only ball bearing No 6308 suitable for pump set of capacity 1 HP

2

-

-

... More
Supply only ball bearing No 6308 suitable for pump set of capacity 2 to 3 HP

4

-

-

... More
Supply only ball bearing No 6308 suitable for pump set of capacity 4 to 5 HP

6

-

-

... More
Supply only ball bearing No 6308 suitable for pump set of capacity 7.5 HP

4

-

-

... More
Supply only ball bearing No 6308 suitable for pump set of capacity 25 HP

2

-

-

... More
Supply only ball bearing No 6308 suitable for pump set of capacity 60 HP

2

-

-

... More
Supply only ball bearing No 6208 suitable for pump set of capacity 1 HP

2

-

-

... More
Supply only ball bearing No 6208 suitable for pump set of capacity 2 to 3 HP

6

-

-

... More
Supply only ball bearing No 6208 suitable for pump set of capacity 4 to 5 HP

6

-

-

... More
Supply only ball bearing No 6208 suitable for pump set of capacity 7.5 HP

4

-

-

... More
Supply only ball bearing No 6208 suitable for pump set of capacity 25 HP

2

-

-

... More
Supply only ball bearing No 6208 suitable for pump set of capacity 60 HP

2

-

-

... More
Supply only gun metal bush suitable for pump set of capacity upto 3 HP

4

-

-

... More
Supply only gun metal bush suitable for pump set of capacity 4 to 7.5 HP

8

-

-

... More
Supply only gun metal bush suitable for pump set of capacity 25 HP

2

-

-

... More
Supply only gun metal bush suitable for pump set of capacity 60 HP

2

-

-

... More
Supply only CI Impeller suitable for pump set of capacity upto 3 HP

1

-

-

... More
Supply only CI Impeller suitable for pump set of capacity upto 4 to 7.5 HP

2

-

-

... More
Supply only CI Impeller suitable for pump set of capacity upto 25 HP

1

-

-

... More
Supply only CI Impeller suitable for pump set of capacity upto 60 HP

1

-

-

... More
Supply only cooling fan blade suitable for pump set of capacity upto 3 HP

2

-

-

... More
Supply only cooling fan blade suitable for pump set of capacity upto 4 to 7.5 HP

3

-

-

... More
Supply only cooling fan blade suitable for pump set of capacity upto 25 HP

1

-

-

... More
Supply only cooling fan blade suitable for pump set of capacity upto 60 HP

1

-

-

... More
Supply only bleaching powder in 25 Kgs bag having 35 % chlorine content of E-in-C branch approved make.

75

-

-

... More
M&L for Cleaning of UG sump of residential area and by draining out complete water removing deposits from bottem,scratching out silt ,dirt from surfaces of the tank of inner surfaces . carrying out two coat of lime wash on inner surfaces, after drying up of capacity 30000 ltr located at domestic area. All as directed and approved by Engineer-in-Charge

1

-

-

... More
M&L for Cleaning of UG sump of Adm block area and by draining out complete water removing deposits from bottem,scratching out silt ,dirt from surfaces of the tank of inner surfaces . carrying out two coat of lime wash on inner surfaces, after drying up of capacity 20000 ltr located at domestic area. All as directed and approved by Engineer-in-Charge

1

-

-

... More
M&L for Cleaning of RCC tank of techanicall Bldg and by draining out complete water removing deposits from bottem,scratching out silt ,dirt from surfaces of the tank of inner surfaces . carrying out two coat of lime wash on inner surfaces, after drying up of capacity 20000 ltr located at Technical area. All as directed and approved by Engineer-in-Charge

2

-

-

... More
M&L for Cleaning of UG sump of techanicall area and by draining out complete water removing deposits from bottem,scratching out silt ,dirt from surfaces of the tank of inner surfaces . carrying out two coat of lime wash on inner surfaces, after drying up of capacity 75000 ltr in two component, located at Technical area. All as directed and approved by Engineer-in-Charge

1

-

-

... More
M&L for Cleaning of UG sump of Bio complex area and by draining out complete water removing deposits from bottem,scratching out silt ,dirt from surfaces of the tank of inner surfaces . carrying out two coat of lime wash on inner surfaces, after drying up of capacity 75000 ltr in two component and 25000 ltr in one component located at Technical area. All as directed and approved by Engineer-in-Charge

1

-

-

... More
M&L for repair and removal of leakage in the main pipe line by any means like rethreading replacement of socket, union, inserting nipple etc including earth work as required to complete the job for pipe size of 20 to 25 mm bore

15

-

-

... More
M&L for repair and removal of leakage in the main pipe line by any means like rethreading replacement of socket, union, inserting nipple etc including earth work as required to complete the job for pipe size of 32 to 50 mm bore

12

-

-

... More
S&F in repair CI non return valve vertical type suitable for 80 mm bore pipe line including nut bolt washer and rubber gasket all as directed including taking out existing one and shifting to store.

1

-

-

... More
S&F in repair CI non return valve vertical type suitable for 150 mm bore pipe line including nut bolt washer and rubber gasket all as directed including taking out existing one and shifting to store.

1

-

-

... More
S&F flexible rubber coupling of delivery vertcal pipe line of out let of pump set of size 80 mm bore with nut bolt washer etc after diisconnecting and taking out old existing coupling with old nut bolt and washer etc, complete all as directed.

1

-

-

... More
S&F flexible rubber coupling of delivery vertcal pipe line of out let of pump set of size 150 mm bore with nut bolt washer etc after diisconnecting and taking out old existing coupling with old nut bolt and washer etc, complete all as directed.

1

-

-

... More
S&F Brass/GM foot valve vertical type suitable for 40 mm bore pipe line including threading to pipe and connecting all as directed including taking out existing one and shifting to store Make leader or equivallent.

2

-

-

... More
Inspection, tuning, callibration,connecting of cable, rewiring where required from control panel to control switches and other equipment of auto functional system ,detection of fault and rectification, commisioning of main controle panel to make auto functional and testing of complete fire fighting system. Assement of serviceability of all connected equipement of fire fighting system compraising of pump set,motor,pressure tank ,pressure guage ,pressure valve electric controle panel,cable, fire hydrant,hose reel box, vertical duct, controle valves , hoses, rubber reels, syren and measurig equepements to the satisfaction of Eng- in- Charge at DIBER technical area . Minor item like cable upto 1.5 mtr, insulation tape ,marker , lugs ,separater if required will be supply and fixed by contractor, cost of the same is deemed to be included in the item of work.Notes : (i) Replacement of unserviceable parts if required shall be measured and paid for separately under appropriate item of Sch `A` here in after.(ii) Detail inspection/serviciability report will be submitted by the contractor cost of the same is deemed to be included in the item of work all as directed to the satisfaction of E in Charge .

1

-

-

... More
M&L for repair of old existing out door double door hose box doors, locking system and replacement of both existing broken door glasses with existing size complete with rubber beading and denting/welding including painting with two coat of fire red colour enmel paint all as required at site and directed.

2

-

-

... More
M&L for repair of old existing double door duct doors, locking system, hinges and replacement of both door glasses of existing size complete with rubber beading and denting/welding including painting with two coat of fire red colour enmel paint all as directed to the satisfaction of Engr- in -Charge

4

-

-

... More
M&L fire hose box made out of MS sheet having thickness 18 gauge, double door, out door with glass pane, with locking arrengement of size L X W x D (800mm x 600mm x 250mm) fixed on two GI angle iron legs of existing size, duly painted with two coats sythatic enamelled red paint over a coat of red oxide primer and in side with white colour, including PCC foundation suitable for placing two nos of hose reel of size 15 mtr long and nozzel complete,including dismaintling of old existing one complete all as directed.

4

-

-

... More
Disconnecting and taking out old existing unserviceable pressure switches supply & fix new Industrial Pressure switch universal type of exesting size complete all as directed.

2

-

-

... More
Disconnecting and taking out old existing unserviceable pressure switches supply & fix Pressure gauge 4" dia, 0- 14 Kgs rating gauage of exesting size complete all as directed.

3

-

-

... More
Disconnecting and taking out old existing unserviceable safety relief vave of size 25 mm straight type screwed male end of brass/bronze made and supply & fix new safety release valve of size 25mm of brass/bronze complete with testing and as directed.

2

-

-

... More
Disconnecting and taking out old existing unserviceable ampmeter and supply & fix new digital Amp meter three phase bright LED display 4 digits square type complete with nut bolt and testing and commisioning all as directed. Make Schneider Cat 300461and equivalent

2

-

-

... More
Disconnecting and taking out old existing unserviceable voltmeter supply & fix new anolog volt meter three phase bright 0 to 500 V, square type complete with nut bolt and testing and commisioning all as directed. Make AE and equvalent

2

-

-

... More
M&L selector switch 3 Phase suitable for volt meter as per existing one

3

-

-

... More
M&L selector switch 3 Phase suitable for Amp meter as per existing one

3

-

-

... More
Taking out existing defective CI butterfly valve of size 80 mm bore and supply & fix new CI butterfly valves of 80 mm bore incl replacement of rubber gasket, nut and bolt etc. all as directed.

1

-

-

... More
Taking out existing defective CI butterfly valve of size 100 mm bore and supply & fix new CI butterfly valves of 100 mm bore incl replacement of rubber gasket, nut and bolt etc. all as directed.

1

-

-

... More
Taking out existing defective GM gate valve of size 20 mm bore and supply & fix new GM gate valve of size 20 mm bore incl repair/rereplacement of required GI fitting and connected work all as direc ted.

6

-

-

... More
Taking out existing defective GM gate valve of size 25 mm bore and supply & fix new GM brass gate valve of size 25 mm bore incl repair/rereplacement of required GI fitting and connected work all as direc ted.

8

-

-

... More
Taking out existing defective GM gate valve of size 40 mm bore and supply & fix new GM gate valve of size 40 mm bore incl repair/rereplacement of required GI fitting and connected work all as direc ted.

6

-

-

... More
Taking out existing defective GM gate valve of size 50 mm bore and supply & fix new GM gate valve of size 50 mm bore incl repair/rereplacement of required GI fitting and connected work all as direc ted.

8

-

-

... More
Taking out existing defective stand post hydrants landing valves single control of size 63/65 mm bore and supply & fix new fire hydrant landing valves single control of size 63/ 65 mm bore incl replacement of rubber gasket,etc. all as directed.

2

-

-

... More
Taking out existing defective hose reel drum of 30 mtr length ISI marked complete with nozzle and coupling and supply & fix new hose reel drum of 30 mtr length ISI marked complete incl nozzle and coupling all as specified and as directed.

4

-

-

... More
Taking out existing defective RRL hose type-A 15mtr in length, complete with nozzle and coupling supply & fix new RRL hose type-A 15mtr length ISI marked complete incl brass/ GM nozzle,male and femail coupling and all as specified and as directed.

5

-

-

... More
Taking out existing defective Contactor for starter and supply & fix new Contactor of size 3 Phase 415 V 25 to 45 Amp incl replacement of nuts and bolts etc. as required and all as directed.

2

-

-

... More
Taking out existing defective overload relay supply & fix new overload control relay of AC -15 , 4A at 415 V MX0 AC of existing type incl replacement of nuts and bolts etc. as required and all as directed.

4

-

-

... More
Taking out existing defective Contactor for starter and supply & fix new Contactor of size 3 Phase 415 V 9 to 25 Amp incl replacement of nuts and bolts etc. as required and all as directed.

2

-

-

... More
Taking out existing defective single phase preventor supply & fix new single phase preventor three phase incl replacement of nut and bolt etc. all as directed.

3

-

-

... More
Taking out existing defective starter and supply & fix new fully automatic star delta starter AC 415 V, 50 HZ, 3 phase suitable for pump set of capacity Upto 10 HP.

1

-

-

... More
Taking out existing defective starter and supply & fix new fully automatic star delta starter AC 415 V, 50 HZ, 3 phase suitable for pump set of capacity 25 HP.

2

-

-

... More
Taking out existing defective starter and supply & fix new fully automatic star delta starter AC 415 V, 50 HZ, 3 phase suitable for pump set of capacity 60 HP.

1

-

-

... More
Taking out existing defective starter and supply & fix new DOL starter AC 415 V, 50 HZ, 3 phase suitable for pump set of capacity upto 7.5 HP.

2

-

-

... More
Taking out old unserviceable power contractor and supply and fix 4 pole power contractor 18A/20A AC, 3 phase rating Suitable for 7.5HP / 5.6 KW AC Motors Suitable for MK 1 Starters 110V AC 50Hz Control Voltage Coil as directed by Engr in Charge.

3

-

-

... More
Supply and fix MCCB 415 volts, 3 phase, 50 Hz, 3 pole of capacity 125 Amps 16 KA including taking down old unseviceable MCCB all as directed by Engr-in-Charge. Make : L&T/Indo asian/ABB/Havells

2

-

-

... More
Supply and fix MCCB 415 volts, 3 phase, 50 Hz, 3 pole of capacity 63 Amps 16 KA including taking down old unseviceable MCCB all as directed by Engr-in-Charge. Make : L&T/Indo asian/ABB/Havells

2

-

-

... More
Supplying and fixing 5 to 32 A rating, Three pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required

2

-

-

... More
Supplying and fixing 40 to 63 A rating, Three pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required

4

-

-

... More
Supply and fix in replacement power contactor 3 pole,415 volt, 50 HZ, 70 to 100 Amp capacity of Make- L&T as per sample and directed or equivallent make.

1

-

-

... More
Supply and fix in replacement electronic timer 3 to 30 sec 240/415 Volt as required at site type ST 100 of MakeL&T as persample or other equivallant and as directed directed.

2

-

-

... More
Supply and fix water level controller with water level controller probe for draining and filling application 240/415 Volt. Make L&T as per sample or other equivallant make and all as directed.

2

-

-

... More
M& L for supply instalation, testing, commisioning of fire alarm remote response indicator in replacement of existing unserviceable response indicator incl disconnecting, dismantling and taking out existing unserviceable fire remote indicator all as specified and directed.

8

-

-

... More
Fire Alarm sounders / Sirens electronic type horizontal single/two stage continous normal operation for atleast 50 minutes with sound level 65 db to 120 db Measured at 1.5m with sound output Variation of + 5 db 500m range in replacement of existing unserviceable fire alarm hooter/sounder incl disconnecting, dismantling and taking out existing unserviceable fire alarm hooter/sounder all as specified and directed

3

-

-

... More
M& L for supply, instalation, testing and commisioning of fire alarm addressable manual call point resettable type incl disconnecting, dismantling and taking out existing unserviceable fire alarm manual call point all as specified and directed.

5

-

-

... More
M& L for supply, instalation, testing and commisioning of addressable type multisensor heat and smoke cmbination detector incl disconnecting, dismantling and taking out existing unserviceable smoke detector all as specified and directed.

12

-

-

... More
M&L for collect water sample from bore well and testing to the Govt approved laboratory for chemical analysis/micro biological testing like colour , turbidity, pH,TDS, Hardness, Alkalinity etc and collect the report from lab and submitted to the AGE(I) R&D office all as specified and as directed.

2

-

-

... More
Disconnecting and taking out old existing unserviceable LT UG cable of size 10 Sqmm 4 core of any description and in any position complete and Supplying, laying, jointing & testing XLPE insulated PVC sheathed (heavy duty) armoured cable with aluminium conductor for working voltage upto 1100 volts size 10 sqmm, 4 core . complete all as specified and directed. Make- Havells/Plaza/Universal/KEI/Polycab/MESCAB

120

-

-

... More
Disconnecting and taking out old existing unserviceable LT UG cable of size 16 Sqmm 4 core of any description and in any position complete and Supplying, laying, jointing & testing XLPE insulated PVC sheathed (heavy duty) armoured cable with aluminium conductor for working voltage upto 1100 volts size 16 sqmm, 4 core . complete all as specified and directed. Make- Havells/Plaza/Universal/KEI/Polycab/MESCAB

40

-

-

... More
Disconnecting and taking out old existing unserviceable LT UG cable of size 25 Sqmm 3.5 core of any description and in any position complete and Supplying, laying, jointing & testing XLPE insulated PVC sheathed (heavy duty) armoured cable with aluminium conductor for working voltage upto 1100 volts size 25 sqmm, 3.5 core . complete all as specified and directed. Make- Havells/Plaza/Universal/KEI/Polycab/MESCAB

60

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth strip 25 X 4 mm as earth lead in 40 mm dia GI light grade protection pipe including charcoal, salt, bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion

2

-

-

... More
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire

20

-

-

... More
S & F Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed including taking out old unserviceable float vales.

12

-

-

... More
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 18.33.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 including

1

-

-

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 18.32.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.