Military Engineer Services Tender
View complete overview of Uttarakhand MES Tender
Military Engineer Services - MES Tender
Coronavirus COVID 19
Eprocure
Opening Date6 Sep 2019
Closing Date30 Sep 2019
Tender Amount₹ 22,26,370 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 60,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_MES_280221_1Bid Award Id
ViewTender No
8229/PGH/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
184.12
-
-
... More
M & L for dry sand cushioning to underground cables in layer (8 cm thick before laying of cables and 15 cm thick after laying and stretching of cable) as in trenches for cable protection or under floor or in foundation and gentally hand ramming and consolidation complete all as specified and directed. Note:- Sand thickness shall be measured only 18 cm after punning .
97.2
-
-
... More
M & L for brick protection cover of UG cable by using old size sub class 'B''common burnt clay building bricks, laid dry and flat abutting each other with width equal to length of the brick and gap between adjacent brick n.exc 10 mm complete all as specified and directed.
9.6
-
-
... More
M & L for cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation of pole / stay / strut, filling and mass cocrete etc complete all as specified and directed.
6
-
-
... More
M & L for cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in cills, copings, pole pedestals, plinth courses and the like including necessary form work, weathering, slightly rounded or chamfered angles and throating etc complete all as specified and directed.
2.81
-
-
... More
Supply, install steel tubular swaged poles type 410-SP-31 (9 mtr long) with mild steel base plate of size 30cm x 30cm x 6mm thick, welded at bottom and cap finial taper plugs, bolt, nuts and screw as specified and fixed in true vertical position complete including dismantling of old unserviceable existing pole by breaking PCC coping and making good as existing grund from site complete all as specified and directed.
Note :- (a) Earth work and PCC in foundation / coping / padestal shall be measured and paid for separately under respective items.
(b) Poles shall be painted with two coats of black bituminous paint throughout internally, and externally upto planting depth. The remaining portion of the exterior surface shall be painted with two coats of aluminium paint over a coat of red oxide primer.
14
-
-
... More
M & L for pruning / trimming of tree branches with T&P not more than 100 mm dia surrounding 2.0 mtr wide all around the LT / HT overhead line, cleaning the site and removing the cut branches outside MoD land complete all as specified and directed.
180
-
-
... More
Disconnecting and taking out LT OH line conductor with GI earth wire of any size fixed on existing cross arms by loosing the binding wire from the insulator where ever necessary and refixing / restraining, securing, tightening including cutting the tree branches, obstacle to the OH lines (approx 3.00 metres clearance all around the outer conductor) and bushes on ground in each span n.exc 35 m (average) for three phase and neutral with street light feeder and GI guard wire complete all as specified and directed.
45
-
-
... More
~Dtto~ all as per Srl item No 11 above but for three phase and neutral with GI guard wire.
15
-
-
... More
~Dtto~ all as per Srl item No 12 above but for one phase and neutral with GI guard wire.
20
-
-
... More
S & F galvanized steel stay assembly complete with stay rod 20 mm dia including stay wire 7 / 3.15 mm fixed for stay of poles including necessary MS clamp of flat iron 50 x 6 mm, nuts & bolts etc complete including dismantling of stay assembly from site and making good as per existing complete all as specified and directed.
Note:- Earth work & PCC in foundation / coping shall be measured and paid for separately.
10
-
-
... More
Dismantling of old rusted cross arms etc and S & F new cross arms, bracings, supports, clamps, back plates etc, fabricated from structural steel section including bolts, nuts, washers, welding, bending to shape, drilling holes etc and painted with two coats of aluminium paint over one coat of red oxide primer complete all as specified and directed.
6
-
-
... More
Dismantling of old unserviceable pin type insulator and S & F new pin type porcelain, vitreous white / brown / green insulator of size 100 mm height and 65 mm dia suitable for 1100 Volt grade including one galvanized mild steel spindle and two galvanized iron washers and nut etc complete all as specified and directed.
25
-
-
... More
Dismantling of old unserviceable shackle type and S & F new shackle type porcelain vitreous white / brown / green insulator of size 75 mm height and 90 mm dia, suitable for 1100 Volt grade including galvanized mild steel straps of size 31 mm x 3 mm, washers, bolts and nuts etc complete all as specified and directed.
25
-
-
... More
Dismantling of old unserviceable Air Break Gang operated switch vertically mount and S & F new triple pole mechanically operated, mounted on insulator and steel frame and operating mechanism from ground level for current rating upto 200 amps for 11 KV complete all as specified and directed.
3
-
-
... More
Dismantling of old unserviceable drop out fuse and S & F new 11000 Volt expulsion fuse single pole, swing out type, current carrying capacity above 50 Amps and upto 100 Amps complete all as specified and directed.
9
-
-
... More
M & L for preparation of old painted surfaces of existing steel swaged pole and applying one coat of aluminium paint starting from 1.5 m above the top of PCC pedestal complete all as specified and directed.
200
-
-
... More
M & L for preparation of old painted steel surfaces of existing channel, angle iron, brackets clamps etc fixed on pole and applying one coat of aluminium paint complete all as specified and directed.
10
-
-
... More
M & L for preparation of old painted exposed surfaces of steel / PCC pole from top of PCC pedestal upto 1.5 m and applying one coat of synthetic enamel paint in 150 mm wide strips alternatively in white and black colour complete all as specified and directed.
200
-
-
... More
S & F in repair lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 KA, suitable for 11000 Volt grade complete all as specified and directed.
1
-
-
... More
Dismantling old ACSR conductor service feeder distribution span and S & F new ACSR conductor of any type and size straching properly on insulators and binding with aluminium binding wires, jumpers including fixing on insulators on each pole in span and tightening with permissible sag in between span etc complete all as specified and directed.
Note:- Measurement and payment shall be made for horizontal distance between centres of two adjacent poles and 3 % extra for sag, jointing jumper etc.
2
-
-
... More
Supply and fix in repair 3 line spacer for overhead conductor complete all as specified and directed.
80
-
-
... More
Supply and fix in repair 4 line spacer for overhead conductor complete all as specified and directed.
70
-
-
... More
Dismantling of old unserviceable pin type insulator and S&F new pin type porcelain, vitreous white / brown / green insulator of size 150 mm height and 150 mm dia for 11000 volt grade including one galvanized mild steel spindle and two galvanized iron washers and nut etc complete all as specified and directed.
10
-
-
... More
Dismantling of old unserviceable disc type insulator and S&F new disc type porcelain, vitreous white, brown or green insulator of size 145 mm height and 255 mm dia, ball and socket type two in series assembly for tension with tension clamp, for 11000 volt grade complete all as specified and directed.
10
-
-
... More
Dismantling unserviceable GI wire and S & F new GI wire 4.00 mm dia for earth from pole to pole complete all as specified and directed.
1
-
-
... More
S & F in repair indoor type cable end terminations jointing kit heat shrinkable complete with all accessories and jointing materials suitable for 3 core 50 / 95 Sqmm XLPE HT cable (kit shall not be older than 3 months from the date of manufacture) complete all as specified and directed.
4
-
-
... More
S & F in repair outdoor type cable end termination jointing kit heat shrinkable complete with all accessories and jointing materials suitable mounting on channel/angle iron with and including cable pieces of suitable size length and line type vice for 3 core 50/95 Sqmm XLPE HT cable (kit shall not be older than 3 months from the date of manufacture) complete all as specified and directed
5
-
-
... More
S & F in repair straight through jointing kit heat shrinkable complete with all accessories and jointing materials suitable mounting on channel / angle iron with and including cable pieces of suitable size length and line type vice for 3 core 50 to 95 Sqmm XLPE HT cable (kit shall not be older than 3 months from the date of manufacture) complete all as specified and directed
3
-
-
... More
Dismantling of existing steel tublar swaged pole 11 mtr long and S & F new steel tubular swaged poles type 410 SP-55 (11 mtr long) complete with cast iron base plate, finial taper plug, bolts & screws as specifed all as specified and directed.
Note:- (a) Earth work and PCC in foundation/ coping/ padestal shall be measured and paid for separately under respective items.
(b) Poles shall be painted with two coats of black bituminous paint throughout internally, and externally upto planting depth. The remaining portion of the exterior surface shall be painted with two coats of aluminium paint over a coat of red oxide primer.
3
-
-
... More
M & L for in reapir earthing for sub station equipments complete with galvanized steel earth plate of size 600 x 600 x 6 mm thick burried directly into ground (earth pit) not less than 2.25 m deep below ground level, top edge of earth plate not less than 1.5m below ground level, connected to galvanized mild steel strip 32 x 6 mm (7.5m long) by means of rivets at one end and the other end connected to equipments body and neutral panel board, including GI pipe light grade of 40mm nominal bore for protection of Earth strip and watering pipe medium grade of 20mm nominal bore fitted with 0.63 mm thick GI sheet funnel with wire mesh etc complete including charcoal and salt , necessary mild steel clamps, nuts, bolts etc, earth work and excavation in any type of soil, making good to floor with PCC (1:2:4) type B-1, earth pit and precast RCC cover 65mm thick duly reinforced with 6mm dia MS round bars @ 100 mm C/C both ways with lifting handle of 10 mm dia MS bar, earth test point & making good to floor, complete all as specified and directed.
12
-
-
... More
Taking down outdoor / Indoor type transformer from foundation / plateform carefully by dismantling connections for repair and transporting the same upto the factory, draining out transformer oil from the transformer, dismantling and taking out burnt primary and secondary coil of transformer of capacity 75 KVA /100 KVA, 11KV/415 Volt, copper bound to assertain the defective HV/LV coils, rewinding made of copper winding coil of suitable size according to the capacity of transformer with packing/insulating material complete, cleaning of cooling fins/radiator and re-assembling the same after renewal of defective parts and testing the transformer at factory, transporting back to AGE Banbasa and re-fix the same in position on four pole structure, reconnecting all electric connections and commissioning complete all as specified and directed. Note:- (i) New spare parts replaced shall be measured and paid for separately under respective items of schedule A. (ii) After opening the Transformer, list of defective/unserviceable parts to be prepared jointly by Engineer-in-Charge and the contractor. (iii) The quoted rate of the minor unserviceable/defective parts shall be deemed to upto Rs. 300/-
2
-
-
... More
Supply only HV bushing 11 KV grade with brass spindle 4 Nos hexagonal nut & Bolts suitable for transformer capacity 75 KVA / 100KVA, required for transformer complete all as specified and directed. .
6
-
-
... More
Supply only LV bushing 1100 volt grade with brass spindle and 04 Nos hexagonal suitable for transformer capacity 75 KVA, required for transformer complete all as specified and directed.
6
-
-
... More
Supply only Cork sheet gasket required for transformer complete all as specified and directed.
2
-
-
... More
Supply only Breather assembly, required for transformer, complete all as specified and directed.
5
-
-
... More
Supply only 40 mm dia bore stop valve cast copper alloy screwed down high pressure (drain valve), required for transformer complete all as specified and directed.
5
-
-
... More
Supply only Oil temperature gauge dial type, required for transformer complete all as specified and directed.
5
-
-
... More
Supply and fix in repair MCCB, 4 pole, 415 V, adjustable type, 200 Amp, 36 KA complete all as specified and directed. Make - L&T / C&S / ABB
3
-
-
... More
Supply and fix in repair MCCB, 4 pole, 415 V, adjustable type, 125 Amp, 16 KA complete all as specified and directed. Make - L&T / C&S / ABB
3
-
-
... More
Supply and fix in repair MCCB, 4 pole, 415 V, adjustable type, 100 Amp, 16 KA complete all as specified and directed. Make - L&T / C&S / ABB
3
-
-
... More
Supply and fix in repair MCCB, 4 pole, 415 V, adjustable type, 63 Amp, 16 KA complete all as specified and directed. Make - L&T / C&S / ABB
3
-
-
... More
Supply and fix in repair MCCB, 4 pole, 415 V, adjustable type, 400 Amp, 50 KA complete all as specified and directed. Make - L&T / C&S / ABB
3
-
-
... More
Taking down existing unserviceable Volt Meter and S & F new Volt Meter (0-500V), 3 phase, 415 volt complete all as specified and directed.
5
-
-
... More
Taking down existing unserviceable Amp Meter and S & F new Amp Meter of 0-200 Amps with CTs complete all as specified and directed.
5
-
-
... More
Supply and replacing / topping up of transformer oil with new transformer oil (ISI Marked) duly centrifuged and tested for dielectric strength not below from 45 to 60 KV in transformer complete all as specified and directed.
600
-
-
... More
Rapir and Maintenance and complete over hauling of oil circuit breaker of capacity 400 Amps of make Crompton Greaves, SM No. 186130 and MES Nos. L-2759C, L-2760C, L-2761C and L-2762C at MRS including de-assembling of operating mechanism parts, well cleaning with petrol and CRC-226, replacing unserviceable/defective parts and accessories, oiling/greasing of moving parts including re-assembling, fine setting of mechanism, removing oil tank, well cleaning and decarbonizing of arc control pot, fixed and moving contracts, hinges contracts and replacement unserviceable parts, insulating oil and re-assembling and making OCB in perfect operational in manual and electrical mode including well cleaning the complete panel board main bus bar, carbonizing all joint, bus bars, CTs, PTs, spouts metal parts and replacing unserviceable parts and components etc, complete all as specified and directed. Note:- New spare parts replaced shall be measured and paid for separately under respective items of Schedule ‘A’.
4
-
-
... More
Supply only Terminal bushing assembly (hinges end) suitable as per sample complete all as specified and directed.
6
-
-
... More
Supply only Terminal bushing assembly (ACP end) suitable as per sample complete all as specified and directed.
6
-
-
... More
Supply only PT connector with lugs & rod complete all as specified and directed.
3
-
-
... More
Supply only selector switch for Amp Meter complete all as specified and directed.
10
-
-
... More
Supply only selector switch for Volt Meter complete all as specified and directed.
10
-
-
... More
Supply only KVA Meter digital type complete all as specified and directed.
1
-
-
... More
Supply only complete wiring change for 1 No incoming , 3 Nos outgoing OCB panel complete all as specified and directed.
1
-
-
... More
Supply only indicator 24 volt DC complete all as specified and directed.
10
-
-
... More
Supply only indicator 110 volt DC complete all as specified and directed.
10
-
-
... More
Supply only digital Volt Meter for 110 volt AC complete all as specified and directed.
4
-
-
... More
Supply only CT 100 / 50 / 5 complete all as specified and directed.
3
-
-
... More
Supply only CT 60 / 30 / 5 complete all as specified and directed.
3
-
-
... More
Supply only travelling bushing epoxy complete all as specified and directed.
3
-
-
... More
Supply only bushing rod copper complete all as specified and directed.
3
-
-
... More
Supply only seperator bus bar complete all as specified and directed.
6
-
-
... More
Supply only seperator CI complete all as specified and directed.
10
-
-
... More
Supply only spout epoxy complete all as specified and directed.
6
-
-
... More
Supply only Male moving contact (copper) complete all as specified and directed.
6
-
-
... More
Supply only Female moving contact (copper) complete all as specified and directed.
6
-
-
... More
Dehydration, centrifuging, filtration, cleaning and drying the wetness of transformer oil to bring the electric strength as required in transformer outdoor/indoor type 11/433 KV at different locations at Banbasa Mil Camp area by Dehydration plant having minimum capacity 60 ltr per hr including testing of oil before and after dehydration / filtration for each equipment for satisfaction performance complete all as specified and directed.
2000
-
-
... More
M & L for painting of transformer 11 KV, 415 V (50 to 200 KVA) indoor / outdoor type installed at 4 pole structure or on floor including cleaning, scrapping of exposed surfaces and painting with one coat of synthetic enamel paint of approved shade with spray machine including writing MES No. and Machine No. with black paint with letter size 15 mm wide and 50 mm long complete all as specified and directed.
5
-
-
... More
S & F in repair battery brass terminals heavy duty of approved quality complete all as specified and directed.
8
-
-
... More
Supply and fix in repair PVC hose pipe, 100 mm dia branded ISI Marked heavy duty of best quality complete all as specified and directed.
25
-
-
... More
Supply and fix in repair PVC hose pipe, 40 mm dia branded ISI Marked heavy duty of best quality complete all as specified and directed.
30
-
-
... More
Supply and fix in repair PVC foot valve of size 100 mm dia suitable as per sample complete all as specified and directed.
1
-
-
... More
Supply and fix in repair copper lugs of size 95 to 150 Sqmm complete all as specified and directed.
15
-
-
... More
Supply and fix in repair copper lugs of size 70 sqmm complete all as specified and directed.
30
-
-
... More
Supply and fix in repair copper lugs of size 50 sqmm complete all as specified and directed.
30
-
-
... More
Supply and fix in repair copper lugs of size 35 sqmm complete all as specified and directed.
20
-
-
... More
Supply, laying & testing in replacement XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts, Cable size area 95 sqmm nominal cross x 3 core complete all as specified and directed. NOTE:- Excavation & eartwork shall be measured and paid separately under respective items
110
-
-
... More
Supply, laying & testing in replacement for XLPE Cable size 120 Sqmm nominal cross section x 3.5 core insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including suitable size aluminium lugs complete all as specified and directed . NOTE:- Excavation & eartwork shall be measured and paid separately under respective items
70
-
-
... More
Supply, laying & testing in replacement for XLPE Cable size 150 Sqmm nominal cross section x 3.5 core insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including suitable size aluminium lugs complete all as specified and directed . NOTE:- Excavation & eartwork shall be measured and paid separately under respective items
100
-
-
... More
Supply, laying & testing in replacement for XLPE Cable size 10 Sqmm nominal cross section x 4 core insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including suitable size aluminium lugs complete all as specified and directed . NOTE:- Excavation & eartwork shall be measured and paid separately under respective items
100
-
-
... More
Supply, laying & testing in replacement for XLPE Cable size 16 Sqmm nominal cross section x 4 core insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including suitable size aluminium lugs complete all as specified and directed . NOTE:- Excavation & eartwork shall be measured and paid separately under respective items
400
-
-
... More
Supply and fix in repair LT synthetic insulating rubber matting 2 m x 1m x 10 mm thick complete all as specified and directed. Make: Jyoti
4
-
-
... More
Supply and fix in repair LT synthetic insulating rubber matting 2m x 1m x 19 mm thick complete all as specified and directed.
4
-
-
... More
Supply, laying & testing in replacement for XLPE Cable size 50 Sqmm nominal cross section x 3.5 core insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including suitable size aluminium lugs complete all as specified and directed . NOTE:- Excavation & eartwork shall be measured and paid separately under respective items
100
-
-
... More
Supply, laying & testing in replacement for XLPE Cable size 70 Sqmm nominal cross section x 3.5 core insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including suitable size aluminium lugs complete all as specified and directed . NOTE:- Excavation & eartwork shall be measured and paid separately under respective items
100
-
-
... More
Supply and fix in replacement battery 12 Volt 80 AH complete all as specified and directed. Make: Exide, AMARON
1
-
-
... More
Disconnecting GOD of capacity 11 KV, dismantlig of GOD for complete repair & overhauling, checking the serviceablity of spares & operating mechanism, replacement of defective/worn out spares for making the GOD functional including operating mechanism, oiling, greasing of moving parts, fine settting of mechanism making the GOD perfect operational in mannual mode complete all as specified and directed.
Note:- New spare parts replaced shall be measured and paid for separately under respective items of Schedule ‘A’.
3
-
-
... More
Supply only 11 KV post type insulator complete all as specified and directed.
8
-
-
... More
Supply only SRBP tube with metal fitting on both ends complete all as specified and directed.
3
-
-
... More
Supply only top contact complete all as specified and directed.
3
-
-
... More
Supply only bottom contact complete all as specified and directed.
3
-
-
... More
Supply only fibre glass tube complete all as specified and directed.
3
-
-
... More
Supply only fibre tube with metal fittings on both ends complete all as specified and directed.
3
-
-
... More
Dismantling and taking down existing unserviceable lightening arrestor HT of any capacity & any description, fixing, commissioning & testing of distribution class lightening arrestor of rating 12 KV capacity & 10 KA NDC confirming to IEC-60099-4-2001 including bracket, clamps, nuts, bolts and washers complete all as specified and directed.
4
-
-
... More
~Dtto~ all as per Srl item No. 97 above but of capacity 9 KVA / 5KA.
4
-
-
... More
M & L for preparation of old painted surface of two pole structrure made of steel tublar pole of 11 mtrs long including protection pipes, cross arms, clamps, climbing devices, etc. and applying one coat of aluminium paint on all the metallic surfaces complete all as specified and directed.
4
-
-
... More
M & L for preparion of old painted surface of four pole structrure made of steel tublar pole of 11 mtrs long including protection pipes, cross arms, clamps, climbing devices, etc. and applying one coat of aluminium paint on all the metallic surfaces complete all as specified and directed.
4
-
-
... More
Supply and fix in repair of burnt / perished cable ends on incoming and outgoing feeders of panel equipment and other machinery including cutting of burnt ends, preparing / dressing of cable ends with 50 sqmm cable lugs complete all as specified and directed.
5
-
-
... More
~Dtto~ all as per Srl item No 102 above but of size 70 Sqmm cable lugs complete.
5
-
-
... More
~Dtto~ all as per Srl item No 102 above but of size 95 Sqmm cable lugs complete.
6
-
-
... More
Supply and fix in repair tinned copper fuse wire 16 amp complete all as directed.
1
-
-
... More
Supply and fix in repair tinned copper fuse wire 20 Amp complete all as directed.
1
-
-
... More
Supply and fix in repair tinned copper fuse wire 25 amp complete all as directed.
1
-
-
... More
S & F security light luminaire comprising of epoxy powder coated housing enclosed with glass cover in frame 40 Watt LED with IP protection 65 suitable with suitable GI pipe bracket 40 mm dia 1.20 mtr long light grade including clamps, nut & bolts etc and making electric connection with 2 core 1.5 Sqmm PVC copper conductor cable complete all as specified and directed.
Make:- Philips / Bajaj / HPL
35
-
-
... More
Taking down old userviceable street light fittings HPSL / HPMVL tube light of any capacity complete with and including GI pipe brackets, mild steel clamps, bolts and nuts from the existing poles / walls after disconnecting and removing complete all as specified and directed.
102
-
-
... More
S & F security light luminaire comprising of epoxy powder coated housing enclosed with glass cover in frame 20 x 1.2 W for BSLST 20 LED with IP protection 65 with suitable GI pipe bracket 40 mm dia 1.20 mtr long light grade including clamps, nut & bolts etc and making electric connection with 2 core 1.5 sqmm PVC copper conductor cable complete all as specified and directed.
Make:- Philips / Bajaj / HPL
32
-
-
... More
S & F security light luminaire comprising of epoxy powder coated housing enclosed with glass cover in frame 45 W for BSLST 20 LED with IP protection 65 with suitable GI pipe bracket 40 mm dia 1.20 mtr long light grade including clamps, nut & bots etc and making electric connection with 2 core 1.5 sqmm PVC copper conductor cable complete all as specified and directed.
Make:- Wipro / Philips / Bajaj.
35
-
-
... More
Taking down existing street light fitting (LED 25 to 45 watts) any type from old poles, de-assembling, testing of parts for serviceability, sorting serviceable and unserviceable parts, replacing unserviceable parts, re-asembling using new accessories including S & F new copper wire of suitable size of making internal connections, testing and re-fixing in position complete all as specified and directed.
Note:- New spare parts replaced shall be measured and paid separately under respective items of Schedule ‘A’.
200
-
-
... More
Supply only Electronic driver of LED 45 Watt, suitable for LED secuity light complete all as specified and directed.
100
-
-
... More
Supply only Electronic driver of LED 25 Watt, suitable for led secuity light complete all as specified and directed.
100
-
-
... More
S & F in repair Automatic street light timer switch Single phase 3 KW 230 V Swadeep -02 EC 3 KW 1P model as a pole mountable SMC Enclousure consisting of nature switch -02 as the controlling unit, power contactor(s) & MCBs 25 A (both input-output) of suitable power rating and copper wiring (Min 10 Sq mm) with proper lugs & terminal blocks. The SMC enclosure comes complete with openable door and mounting clamps. The Sintex make enclosure is made of UV stablized. FR grade special moulding compound and it is Rust proof, Electric Shock proof, Termite proof, outdoor openable mountable confirming to IP-54 complete all as specified and directed.
Make - Swadeep / Hager/ L&T
10
-
-
... More
M & L for in repair of existing automatic voltage stablizer (Servo controlled) three phase naturally oil cooled indoor type and designed for input variation between 340V to 460V with output voltage stablized at 415 with accuracy + 2.5 % and speed of correction & volts per second and of capcity 100 KVA by replacing of unserviceable, Ameter, Voltmeter, selector switches, insulating oil and other spare parts complete all as specified and directed.
1
-
-
... More
S & F in replacement automatic Battery charger 12 V Suitable for charging of Battery 12V and 150 AH complete all as specified and directed.
1
-
-
... More
M & L for cleaning the existing under ground duct / trench by removing the PCC Precast Cover and existing cable from duct and repair the side wall of duct by plaster wherever is broken and provide PCC cover over the duct and fill the duct by sand complete all as specified and directed.
Note :- The Qty of sand and PCC Cover will be measure in respective item.
30
-
-
... More
M & L for Precast PCC Cover 1:3:6 type C-1 ( using 20 mm graded aggregate) and fix over the duct as per existing size required at site complete all as specified and directed.
4
-
-
... More
M & L for in repair finding out the fault of LT cable upto 50 Sq mm by digging of existing trench and removing the brick protection cover and all material and restore the supply by using LT straight through joint and making as per existing complete all as specified and directed.
Note:- The rate of straight through joint are deemed to the quoted rate and excavation,sand,brick protection cover returning filling, removing of surplus soil will be measured and paid separetly under respectiv item of sch.
5
-
-
... More
M & L for in repair finding out the fault of LT cable above 50 Sq mm upto 150 Sq mm by digging of existing trench and removing the brick protection cover and all material and restore the supply by using LT straight through joint and making as per existing complete all as specified and directed.
Note:- The rate of straight through joint are deemed to the quoted rate and excavation,sand,brick protection cover returning filling, removing of surplus soil will be measured and paid separetly under respectiv item of sch.
6
-
-
... More
M & L for in repair 40 mm dia bore galvanized iron tubing, light grade, ISI Marked, for protection of cable fixed to pole / wall or laid in floors/road crossing ducts with all necessary fittings like clamps, bolts, nuts and washers etc complete all as specified and directed.
97
-
-
... More
M & L for in repair 80 mm dia bore galvanized iron tubing, light grade, ISI Marked, for protection of cable fixed to pole / wall or laid in floors/road crossing ducts with all necessary fittings like clamps, bolts, nuts and washers etc complete all as specified and directed.
30
-
-
... More
Supply and lay stone aggregate of gauge 80 to 150 mm graded beneath the four / two pole structure and sorrounding area of existing transformer by removing the existing vegetable growth , bushes from roots and level the the ground complete all as specified and directed.
13
-
-
... More
Supply, laying & testing in replacement for XLPE Cable size 25 Sqmm nominal cross section x 4 core insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including suitable size aluminium lugs complete all as specified and directed . NOTE:- Excavation & eartwork shall be measured and paid separately under respective items
400
-
-
... More
Supply and fix in repair energy conservation LED Flood light luminaries of 100 W with IP protection 65 including necessary mounting clamps with nuts & bolts & connection with sutable size of cable complete all as specified and directed.
Make: Philips / HPL / Wipro
14
-
-
Evaluation Notes How It Works ?