Military Engineer Services Tender

View complete overview of Uttarakhand MES Tender

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date30 Jul 2022
Closing Date31 Aug 2022
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
6 Conductors with / without GI wire

50

-

-

... More
Taking down unsv pin type insulator and providing new pin type, porcelain vitreous white brown or green insulator including one galvanized mild steel spindles, two galvanized iron washers and one galvanized iron nut 100mm height, 65 mm dia for 1100 Volt grade complete all as specified. Make BHEL/Pactil/Rastriya/Jaipuria.

10

-

-

... More
M&L for replacement of shackle type porcelain, vitreous white brown or insulator working under 1100 volts grade , pressure of height 75 mm & 90mm dia insulators, dia of bolt 12mm , section of straps 31 x 3mm, washers, nuts complete all as specified & directed. Make Pactil/BHEL/Rastriya//Jaipuria.

10

-

-

... More
Taking down U/S stay assy and M&L for stay assy comprising of MS stay plate of size 23cmx23cmx6mm thick, stay rod with nuts 215cm ling 20mm dia , MS/GI stay bow 40cm lingh with 2 Nos GI thimbles, galvanized stay wire standard size 7/4mm of suitable length, loop insulation size 65x90mm clearance of hole 16mm & other accessories including excavation earth work & PCC work complete all as per SSR Pt-1 plate No-1 complete all as specified and directed. Note : MS clamps will be measured & paid separately in respected items.

5

-

-

... More
M&L for cleaning away all grass, vegetation, saplings, shrubs, undergrowth, roots and trees up to 50 cm girth from the area surrounding of E/M installations, under HT< over head lines, 4/2 pole structures, transforemer, installations, yards, surrounding valve chamers and removing the rubbish upto a distance 50 mtr outside the periphery of the area under clearance and dressing the area etc complete all as specified and directed.

4500

-

-

... More
Taking down rusted/unsv mild steel work and M&L for mild steel work as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot , drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.

2

-

-

... More
M&L in replacement of cradles, hexagonal/ rectangular fabricated with galvanised steel wire of size 4mm dia complete all as specified and directed by Engr-in- charge.

0.5

-

-

... More
M&L in repalcement of existing any type or any size aluminium conductor, steel reinforced including binding wire and jumper connect with PG clamp made out of aluminium alloy accodring to IS-617 complete all as specified and directed.

2

-

-

... More
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of pipes and for poles/stay and struts not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and directed

720

-

-

... More
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and exceeding 1.5 metre in depth and not exceeding 3.0 metre in depth for laying of pipes and for poles/stay and struts not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and directed

1

-

-

... More
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and directed.

400

-

-

... More
Removing surplus spoil to a distance not exceeding 50 metre and depositing where directed at a level not exc. 1.5 metre above the starting point complete all as specified and directed.

300

-

-

... More
Supply and laying sand river for cushioning with layers of sand 8 cm before lying of cable and 15 cm after lying of cable (total 23 cm) in trenches complete all as specified & directed. Note: Thickness after punning shall be measured for payment (18 cm thickness after punning)

220

-

-

... More
Supply and laying brick protection cable cover using sub class ‘B’ bricks laid flat adjacent to each other across the length of cable laid dry complete all as specified & directed by Engr-in-charge.

26

-

-

... More
Supply & Fixing in replacement of existing PCC/Steel pole with new steel tubular poles complete with cast iron base plate, final taper, plug, bolts, nuts & washers as specified type 410 SP-31 (9.0 mtr long) including re-fixing of removed accessoreis such as ACSR/AAC conductor, cables, street light fittings, clamps, nuts & bolts etc complete all as specified and directed.Note :- Excavation, MS work and PCC work will be measured and paid separately.

10

-

-

... More
M&L for PCC work type D-2 (1:4:8) with 40mm graded aggregate for foundation to poles / stays/strutus or basements etc complete all as specified and directed.

0.6

-

-

... More
M&L for PCC work type C-2 (1:3:6) with 40mm graded aggregate for foundation to poles / stays/strutus or basements etc complete all as specified and directed.

5

-

-

... More
M & L for PCC work type B-1(1:2:4) with 20 mm graded aggregate for coping ( new and old damage coping) to poles / stays/strutus or basements etc complete all as specified and directed.

3

-

-

... More
M & L for Horizontal Boring of holes under road, pavement, hard standing by trenchless technology using GI Pipe of required dia and necessary machine suitable for 0.4 mpa working pressure complete all as specified and directed Note :- GI pipe will be measeured and paid saperately under respected item.

48

-

-

... More
Taking down old rusted galvanized iron pipe and providing new galvanized pipe 100 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed.

6

-

-

... More
Taking down old rusted galvanized iron pipe and providing new galvanized pipe 80 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed.

12

-

-

... More
Taking down old rusted galvanized iron pipe and providing new galvanized pipe 40 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed.

48

-

-

... More
Taking down old rusted galvanized iron pipe and providing new galvanized pipe 32mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed.

60

-

-

... More
Supply, laying & testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100V grade, cross sectional area as given below for the following complete all as specified and directed

-

-

-

... More
(a) 3.5 core 240 sq.mm.

100

-

-

... More
(b) 3.5 core 185 sq.mm.

100

-

-

... More
(c) 3.5 core 150 sq.mm.

150

-

-

... More
(d) 3.5 core 120 sq.mm.

300

-

-

... More
(e) 3.5 core 95 sq.mm.

200

-

-

... More
(f) 3.5 core 70 sq.mm.

300

-

-

... More
(g) 3.5 core 50 sq.mm.

350

-

-

... More
(h) 4 core 35 Sqmm.

500

-

-

... More
(i) 4 core 25 sq.mm

600

-

-

... More
(j) 4 core 16 sq.mm.

300

-

-

... More
(k) 4 core 10 sq.mm.

300

-

-

... More
(l) 2 core 10 sq.mm.

700

-

-

... More
(m) 01 Core 400 Sqmm

160

-

-

... More
Supply and fixing in replacement of following accessories installed in existing panel (Indoor/Outdoor) including making in coming / out going electric connections complete all as specified and directed with suitable size of copper wire:-

-

-

-

... More
(a) MCCB rating 250 Amp FP, Breaking capacity 36 kA, including over load and short circuit protection, 415 Volts.Make : Legrand/Havells/Simens/Indoasian

3

-

-

... More
(b) -do- but rating FP 200 Amp, 36 kA, Make :Legrand/Havells/Simens/Indoasian

3

-

-

... More
(c) –do- but rating FP 160 Amp, 36 kA ,Make : Legrand/Havells/Simens/Indoasian

4

-

-

... More
(d) –do- but rating FP 125 Amp, 25 kA, Make : Legrand/Havells/Simens/Indoasian

2

-

-

... More
(e) –do- but rating FP 100 Amp, 16 kA, Make : Legrand/Havells/Simens/Indoasian

2

-

-

... More
(f) –do- but rating FP 63 Amp, 16 kA, Make : Legrand/Havells/Simens/Indoasian

2

-

-

... More
(g) –do- but rating TP 100 Amp , 16kA. Make : Legrand/Havells/Simens/Indoasian

2

-

-

... More
(h) MCCB Four pole 630 Amp, 50kA Thermal magnitc adjustable type including over load and short circuit protection, 415 Volts Make : Legrand/Havells/Simens/Indoasian

1

-

-

... More
(j) MCCB Four pole 400 Amp, 36/35kA, Thermal magnitc adjustable type including over load and short circuit protection, 415 Volts Make : Legrand/Havells/Simens/Indoasian

1

-

-

... More
(k) Digital Voltmeter of rating 0-500 V , size 96mm square type

5

-

-

... More
(l) Digital Ammeter of rating upto 0-600 Amp, size 96mm square type

5

-

-

... More
(m) Selector switch rotary type as per existing size and Make.

5

-

-

... More
(n) LED Indicator assy with colour red/ yellow/ blue. (Set of 3)

18

-

-

... More
(o) Current transformer (CT) Copper wound ratio 100/5 Amp (Set of 3 Nos).

2

-

-

... More
(p) –do- but ratio 200/5 Amp. (Set of 3 Nos).

2

-

-

... More
Supply and fixing Onload Change over switch of capacity 400 A, 415 Vols, 50 Hz, confirming to IEC:60947-3, with rotating handle, including dismantling old unserviceable change over switch by disconnection all incoming and outgoing electrical connection from existing indoor LT Panel all as per Havells Cad No. IHNFO0400 or equivalent model in Legrand, Simens.

1

-

-

... More
Supply and fixing for in replacement of LT 1100 volt Line rigid PVC spacers type 4 lines complete all as specified and directed by Engr-in-charge. Make : Rashtriya/Jaipuria Bros.

25

-

-

... More
All as per Item No- 27 above but 3 Line.

15

-

-

... More
All as per Item No- 27 above but 2 Line.

10

-

-

... More
M&L earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level and covered surrounded from all sides with mixture of charcoal and common salt in alternate layers upto 15cm above top of plate and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber (chamber size not less than 300x300x300mm interier diamentions), RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 10 cm c/c both way and 10mm dia handle for cover and MS frame etc., complete all as specified. NOTE: The unit rate includes earth strip and new GI protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.

10

-

-

... More
All as per Item No-30 above but Copper electrode 600mmx600mmx3.15 mm thick and copper strip 25mmx3mm thick

2

-

-

... More
M&L in replacement of unserviceable Bus-bar chamber made out of sheet metal enclosure 200 Amps power coated independent for five connections, copper busbar suitable for 200 amps current rating mounted on wall, including disconnecting all incoming and out going electrical connections complete all as specified and directed Make: : HAvells Cat No. IHBC020006 or equivalent in Legrand/Siemens/C&S/ABB

3

-

-

... More
S & f in replacement of unserviceable TPN DB- VTPN for independent mounting fixed on wall duely flush mounted, 4 way, IP 43, IK 09 with 250 Amp Bus bar Make : C & S cat part No . CSDBMCCB125PDD04S or any equivalent model in ABB/ Havells/Legrand/Siemens

1

-

-

... More
S & F in replacement of u/s MCB TP 32 Amp, 415 Volt, 'c' curve including necessary connection complete all as specified and directed. Make : Legrand cat part No.4086058 or equivalent in Siemens/ABB or equivalent

5

-

-

... More
S & F in replacement of u/s MCB SP 6 to 32 Amp, 415 Volt,'c' curve including necessary connection complete all as specified and directed. Make : Legrand / Siemens/Schenider or equivalent

50

-

-

... More
Material and labour for preparation of old painted surcaces using polish and painting two coats of aluminium paint on exposed surfaces to steel tubular pole of 11 mtr including crossarms, Bracket etc including 5 Nos. of strip / bands painted with postoffice red and nevy blue colour (300 mm each) in alternate layer from coaping, marking of pole number with black synthetic enamel paint 2.5 cm height including in 6" dia circle complete all as directed.

40

-

-

... More
-ditto- as per item no -36 but LT Pole upto 9 mtr.

280

-

-

... More
Supply & fix PVC Junction box of size 350x250x150 mm with Aluminium bus bars 04 Nos fixed on pole with the help of MS nuts bolts and MS clamps-2 Nos of size 40mm X 5mm thick with one No MCB SP 6 Amp capacity includes making suitable hole on pole to take out connections to fitting if required at site and PVC insulated sheathed multistranded copper conductor 3 core 1.5 Sqmm for making connection from junction box to security light fitting complete including cable glands for incoming and outgoing cables all as specified. Make : Syntex/Hensel/Napture

15

-

-

... More
Supply & fix PVC Junction box of size 250x200x105 mm with Aluminium bus bars 02 Nos fixed on pole with the help of MS nuts bolts and MS clamps-1 Nos of size 40mm X 5mm thick with one No MCB SP 6 Amp capacity includes making suitable hole on pole to take out connections to fitting if required at site and PVC insulated sheathed multistranded copper conductor 3 core 1.5 Sqmm for making connection from junction box to security light fitting complete including cable glands for incoming and outgoing cables all as specified. Make : Syntex/Hensel/Napture

50

-

-

... More
M & L for repairing/servicing calibrating Testing and recommissioning ACB, 1.1 KV, out door/indoor type, including replacement of Gasket set adjusting reconditioning stationery and moving contact adujsting link mechanism within limit nut bolt a, washer and required size of thimbles all as directed

5

-

-

... More
Dismantaling of old steel tubular pole LT/HT including excavation, demolition of PCC and disconecting of cross arm and insulators,and shifting it to new location as required on site including all ACSR conductor any size/ cross arm/insulators connections including PCC work with ratio 1:3:6 and coping and testing of overhead line complete all as specified and directeded.

20

-

-

... More
M & L and testing for end termination jointing kit suitable for 1100V, 16- 50 sqmm x 3.5 core XLPE cable heat shrinkable joint complete with jointing material & assessories suitable 1.1KV grade cable for end complete all as specified and directed

5

-

-

... More
M & L and testing for end termination jointing kit suitable for 1100V, 70-120 sqmm x 3.5 core XLPE cable heat shrinkable joint complete with jointing material & assessories suitable 1.1KV grade cable for end complete all as specified and directed

5

-

-

... More
M & L for XLPE grade cable for straight through joint kit suitable for 1100V, 70-120 sqmm, 3.5 core XLPE cable heat shrinable joint, complete all as specified and as directed.

3

-

-

... More
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for finding of the cable fault in underground cable and returning filling (including old bricks and sand) the same after rectification of the cable fault in any type of soil complete all as specified and directed.

450

-

-

... More
M&L for overhauling to outdoor type LT panel/feeder pillar box of any size/ make including insulating to bus bars with shrinkable PVC sleeves of colours red, yellow, blue and black replacement of worn out / us cables as per existing gauge, door rubber beedings, nuts, bolts washers, hinges, thimbles, lugs, cable glands & welding work etc making functional to the system and testing on load complete all as specified and as directed at site by Engr-in-charge.Note:- Spares required for replacement will be measured & paid separately under respective items.

4

-

-

... More
-do- all as per Srl item No. 46 above but indoor type LT Panel/ feeder box.

3

-

-

... More
M&L for painting to indoor/outdoor type LT panel/FP box of size not more than 1.8 m height internally as well as external surfaces complete with two coats of synthetic enameled paint of approved quality including preparation of old surfaces, writing of bus bars & outgoing /incoming locations with white paint gridth upto 2” (50mm) complete all as specified & as directed at site by Engr-in-charge.

5

-

-

... More
M&L for feeder pillar bus bar box of size of size 600x450x550mm of outdoor type, double door, both side openable, locking arrangement, kiosk type, powder coated, 3.15mm thick MS sheet water proof hinged, having 4 Nos aluminium bus bar of 400 Amp duly colour coded mounted on porcelain insulator, with provn of 06 Nos outgoings including MCCB 200 Amps, 4 pole, 36 kA,= 01 No, LED indicator (RYB), 08 Nos, holes in bottom for inlet and outlet cable with suitable size of cable gland and mild steel stand for mounting of panel board made of angle iron of size 50 mm X 50 mm X 6 mm, 1.05 metre high (450mm below ground level and 600mm above ground) along with necessary cement concrete for grouting of panel stand and connecting the panel with earthing complete all as specified and directed by Engineer-in-Charge. Note : (a) Feeder pillar box shall be got fabricated from CPRI approved and shall be from approved list of manufaturer only and depth of panel not less than 55CM. (b) Electric connection between MCCB and Busbar shall be with aluminium strip links duly colour coded. (c) MCCB shall be of make-Havells/Legrand/ABB/C&S (d) PCC for foundation shall be paid in respective item of this schedule.

2

-

-

... More
M & L in repair sub main wiring with 2 single core, 6 Sq. mm, PVC insulated unsheathed, Multi stranded copper conductor FRLS cable 1100 Volts grade incl 6 Sqmm PVC insulated unsheathed multi stranded copper conductor FRLS as continuous earth wire drawn through in new suitable size PVC conduit/casing caping or PVC flexible sleeves connecting with copper lugs to common earth terminals complete all as specified and directed. Note :-(i) Two run of copper cable and one run of earth wire including conduit /PVC Casing/capping shall be measured as one length.

100

-

-

... More
Taking down/removing carefully existing old rusted LT Panel with accessories and Supply, installation, design, fabrication, testing and commissioning of reputed factory made, outdoor kyosk type, double door, both side openeble, LT Panel mounted on floor working on 440V, 3-phase, 50 Hz, AC supply, incluing PCC platform (300mm above from ground level and 450mm depth of foundation), with double door shutters (front and rear side openable) made out of 3.15mm CRCA sheet metal weather proof, dust and vermin proof, extendible type on both sides, seperate cubilcle / partition for switchgear (incoming and outgoings) with aluminium busbar (duly insulated PVC sleeves as per colour code) on suitable insulated supports, common earth bus at bottom, earth terminals on both sides of the panel for connecting earth stations, ammeter, voltmeter with selector switches, indicating lamps LED type for RYB and on / off position, copper wound CTs for measuring and internal wiring with suitable size of PVC insulated copper wire, angle iron 50x50x6 mm frame at bottom, cable entry boxes with independent cable gland and plates at bottom for each cable, lifting lugs, complete to accommodate including provisions for following switchgears all as per Single Line Diagram and as specified and painted as per the 7-tank process and painted for outdoor, weather proof IP-55 protection installation, including PCC work, excavation complete, as directed at site by the Engr-in-Charge. Location :- Surgical Ward, MH Roorkee and Single JCO's Accn, STB-D.

3

-

-

... More
Note : (i) Contractor shall take approval of drawing of LT Panel and its accessories and single line diagram before procuring the Panel. (ii) All electric connections between MCCB's (incoming and outgoing) and aluminium Bus-bar shall preferably with extended terminals of suitable size aluminium only. (iii) Panel shall be got fabricated from CPRI approved and shall be from approved list of manufaturer only and depth of panel not less than 50CM. (iv) Disconnecting all incoming and outgoing UG cables from existing panel and again connecting the same in new panel including excavating "Loop cables" are deemed be included in the rate quoted by the contractor.

-

-

-

... More
(a) Incomer : MCCB 4 Pole, 400A, breaking capacity 50 kA, with in-built Earth fault protection, Adjustable overload 40-100% as per C&S model No. CSE3s400ETM4P-400A, or euqivalent in Legrand/Siemens/ABB

-

-

-

... More
(b) Outgoing feeders : (i) 4 Pole MCCB 160A, 25kA - 2 Nos, Thermal magnetic release and overload 80-100% as per C&S cat no. CSE2M250ATM3P-160A OR equivalent make in Ligrand / Siemens/ABB. (ii) 4 Pole MCCB 100A, 25kA - 3 Nos, Thermal magnetic release and overload 80-100% as per C&S cat no. CSE2M250ATM3P-160A OR equivalent make in Ligrand / Siemens/ABB.

-

-

-

... More
(C) Panel Fabrication and TPN alluminium bus bar of capacity 800 Amp, Amp merter 0-400Amps, volts meter 0-500 Votls for incomming MCCB , indicator (RYB) and selector switchs complete all as specified and directed.

-

-

-

... More
Repairing/ Maint of LT over head lines and routine maintenance of electric supply/ current leakage / Under ground LT cables , servey for vegitation grought over and around of LT OH lines, Repair / Maintenance of LT feeder piller boxes , incl MCCBs / Timer switch , protection devices . electrical accessories in day to day maintenance and making it serviceable in all respect with all replacement of any major part but including small length of wires (not more than 50cm) adhesive cable and other connected major accessories. Work shall also include to check & removal of Vegitetion etc . Note:- (a) Contractors representative incl 01 x Electrician and 01x Mazdoor will report to Engr-in-charge/ JE E/M (Ext Elect) daily at forenoon and afternoon to collect routine/urgent works related to Ext Elecctric supply till completion of contract. The work shall be attended by the contractor immediately.

180

-

-

... More
(b) The contractor will ensure availability of manpower equipped with all sort of petty items such as insulation tape, Jumpers , insulators , nuts, bolts, washers etc required to accomplish the job. The contractor will also ensure as availability of every type of requiste T&P and Mobile phone to his trades man. (c) All routine/urgent jobs recived on job slip will be repaired & got signature of user's and will be deposited to JE E/M with in 24hrs. In case of any delay in attending the complaint more than 24hrs after handing over of routine/urgent works, the contractor shall be liable to pay the penalty of Rs. 1000/- per day.

-

-

-

... More
Supply and spreading graded stone aggregate of size 40 mm at electrical outdoor installation yard 11KV Substations/ Near DP structures etc including leveling of uneven surface, removing vegetation, grass etc complete all as specified and directed by Engr-in-charge.

15

-

-

... More
Taking down carefully old unserviceable security light fittings from pole/wall and S & F in replacement of security light fittings suitable for LED 60 watt with lens including making electrical connection complete with all accessories as per Mare:- Orient cat No. LSFT-060-CT, OR ENDURA PEARLNEOSL60WLED 757PASYTOPC or Crompton Cat No. TRP-409-60-57-SL-GL-NSG.

5

-

-

... More
All as per Item No. 54 above but of capacity 90 watts with lens including making electrical connection complete with all accessories as per Make :- Orient cat No. LSFT-060-CT, OR Havells Cat No-ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO or Crompton Cat No. TRP-411-90-57-SL-GL-NSG.

5

-

-

... More
All as Item no- 54 above but of capacity 200 watts with secondary lens including making electrical connection complete with all accessories as per Orient Cat part No. LFSMU-200-C and Bajaj Cat No. BJFL 200W LED I or Crompton Cat No- LFLN-200-WW/60-M

4

-

-

... More
Supply only PVC electric cable with insulated aluminium conductor (stranded) with inner sheathing of PVC tape and overall PVC sheathed 1100 volts grade, heavy duty, 10 sqmm twin core, weather proof flat with accessories, complete all as specified and directed.

500

-

-

... More
All as per Item No. 57 But of size 2 core 16 Sqmm.

200

-

-

... More
All as per Item No. 57 But of size 2 core 06 Sqmm.

200

-

-

... More
SAHARANPUR AREA

-

-

-

... More
Excavation in trecnhces, n.exc 1.5 m wide and n.exc 1.5 m in depth, for foundation, etc or for shafts, well, cesspits, manholes, pier holes, etc n.exc 10 sq m on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.

120

-

-

... More
Returing, filling, spreading, leveling, watering & well ramming in layers n.exc 25 cm thick as in soil complete all as specified and directed.

54

-

-

... More
Removing excavated soil n.exc 50 mtr and depositing as directed n.exc 1.5 mtr above the starting point complete all as specified and directed.

64

-

-

... More
Supply and laying sand river for cushioning with layers of sand 8 cm before lying of cable and 15 cm after lying of cable (total 23 cm) in trenches complete all as specified & directed. Note: Thickness after punning shall be measured for payment (18 cm thickness after punning)

45.5

-

-

... More
Supply and laying brick protection cable cover using sub class ‘B’ bricks laid flat adjacent to each other across the length of cable laid dry complete all as specified & directed by Engr-in-charge.

6

-

-

... More
M&L for PCC (1:3:6) type C-2 using 20 mm graded stone aggregate as in Coping of pole/Stay etc. including necessary form work for coping and finished the surface even in fair complete all as specified and directed at site.

2.16

-

-

... More
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate in foundation of PCC poles/struts as specified including necessary form work all as specified and directed.

0.22

-

-

... More
M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed.

0.38

-

-

... More
Labour only for stringing, tightening, fixing and connecting ACSR conductor and GI Wire of existing HT/LT overhead line any size any type, between pole to pole, approximate span length 40 to 50m, complete the following all as specified and directed : -

-

-

-

... More
(i) 2 Wire with GI Wire.

20

-

-

... More
(ii) 5 Wire With GI Wire.

40

-

-

... More
(iii) 6 Wire With GI Wire.

20

-

-

... More
M & L for prunning of tree branches of any sizes and dia, not less than 2 Mtr around the LT /HT OH line which obstructing the power supply/ maintenance of electric supply as well as illumination in area including repair of damage broken ACSR conductor, GI wire and jumpers and disposed exc 50 mtr away clearing area and testing of line, complete all as specified and directed. Note : (i) Span length is aproximate 40 to 50m. (ii) Rate quoted are inclusive of repair to damage work in item.

120

-

-

... More
M&L for Painting single pole or struct of LT PCC poles/structure including. cleaning and scrapping the old surface and then two coat of synthetic paint yellow & Black strips 300mm wide alternative from bottom to upward of LT pole upto height of 1.5mtr above embedded portion at GL, and writing pole number, complete the following as specified and directed by EIC.

15

-

-

... More
M&L for Painting of single LT steel tubular, structure including. cleaning and scrapping the old surface and then applying two coat of aluminium synthetic enamel paint over a coat of red oxide primer on all steel structure mounted on pole viz. Cross Arms , Clamps, bolts, nuts, brackets etc. and including painting of pole/ structure ith two coat of synthetic black & yellow enamel paint strip 300 mm wide alternative from bottom to upward of LT pole up to height of 1.5 mtr above the embedded portion of GL and writing pole number balance portion of pole shall be painted with two coats of Aluminium enamel paint over a coat of red oxide primer, complete the following as specified and directed :-

100

-

-

... More
Notes for Item No 11 to 12: - (i) Pole will be cleaned with steel brush to remove old unserviceable paint or scrapped complete surface. (ii) All poles will be numbered all as directed at site. (iii) If painting of poles is not done properly to the entire satisfaction of Engr-in-Charge, the contractor shall be liable to repaint the same with out any extra cost.

-

-

-

... More
Supplying, Laying, Jointing, testing and commissioning cable XLPE insulated armoured LT 1100 grade heavy duty with Stranded aluminum conductor through pipes in ducts, poles/ trenches including fixing of copper lugs, making good to disturbed surface etc for the following cross sectional area, complete the following as specified and directed :- Make:- Grandlay/Havells/Polycab (Note : Excavation and earth work to be measured and paid separately)

-

-

-

... More
(i) 10 Sqmm 2 core

310

-

-

... More
(iii) 35 Sqmm 3.5 core

100

-

-

... More
(iv) 50 Sqmm 3.5 core

100

-

-

... More
(v) 70 Sqmm 3.5 core

400

-

-

... More
(vi) 95 Sqmm 3.5 core

100

-

-

... More
S&F GI tubing 50mm bore light grade includinng taking down from the existing site for cable protection fixed on pole/laid under floor / road/wall etc with fittings including necessary flat iron clamps of size 40 x5 mm etc complete all as specified and directed.

20

-

-

... More
S&F GI tubing 40mm bore light grade including taking down from the existing site for cable protection fixed on pole/laid under floor/wall etc with fittings including flat iron clamp 40 x 5 mm complete all as specified and directed.

30

-

-

... More
M&L for replacement of unserviceable/ damaged PVC jumper for HT/LT of any size and length to transformer or pole for making connection, complete all as specified and directed.

30

-

-

... More
M&L cutting PCC/floor/road and taking out cable and making good with PCC including material as per existing after laying of pipe for cable protection complete all as specified and directed at site of trench not more than 0.30 x 0.30m, complete all as specified and directed.

10

-

-

... More
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, 10 x 2 core cable flat or circular complete all as specified and directed.

180

-

-

... More
Taking down MCCB of any capacity and size, complete all as specified and directed.

9

-

-

... More
Supply and fixing MCCB 400 Amp 4 pole 36 KA, adjustable type, complete all as specified and directed. Make;- Legrand catpart No 4202 07/ Siemens/ Schneider or equivalent

1

-

-

... More
Supply and fixing MCCB 250 Amp 4 pole 36 KA, adjustable typecomplete all as specified and directed. Make;- Legrand catpart No 4202 19/ Siemens/ Schneider or equivalent

2

-

-

... More
Supply and fixing MCCB 200 Amp 4pole 36 KA, adjustable type complete all as specified and directed. Make;- Legrand catpart No 4202 08/ Siemens/ Schneider or equivalent

1

-

-

... More
Supply and fixing MCCB 160 Amp 4 pole 36 KA, adjustable type complete all as specified and directed. Make;- Legrand catpart No 4200 17/ Siemens/ Schneider or equivalent

1

-

-

... More
Supply and fixing MCCB 100 Amp 4 pole 16 KA with thermal magnetic release setting with 100% Icu complete all as specified and directed. Make;- Legrand catpart No 4200 15/ Siemens/ Schneider or equivalent

2

-

-

... More
Supply and fixing MCCB 63 Amp 4 pole 16 KA with thermal magnetic release setting with 100% Icu complete all as specified and directed. Make;- Legrand catpart No 4200 13/ Siemens/ Schneider or equivalent

2

-

-

... More
Supply and fixing set of incoming or outgoing spreaders 4P complete all as specified and directed. Make;- Legrand catpart No 4200 13/ Siemens/ Schneider or equivalent

2

-

-

... More
M&L for repairing LT feeder box/ panel and their doors, inner compartments etc by denting/ welding where required and cleaning, removing old paint by paint remover/scrappers for any number of coats, any width or girth and applying two coats of synthetic enamel paint by spray painting, inside and outside of panels(second coat shall be applied at the interval of one day) of the approved colour, complete all as specified and directed.

6

-

-

... More
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. Clamp 25X3mm, suitable for PCC/Steel tubular pole, bolts and nuts of approved size for LT 20x15 cm size complete.

30

-

-

... More
Supply and labour for spreading stone aggregate of size 40mm at 11 KV sub station/Transformer/panel board/two pole/four pole structure area, complete all as specified and directed.

3

-

-

... More
S&F in replacement LED type Indicating lamps for LT panel, RYB colour, complete all as specified and directed.

6

-

-

... More
S&F Street light timer panel, single phase with maximum load of 12 Kw with inbuilt astronomical time switch, 65 Amp contactor, 63 Amp SPN confirming to IS/IEC/604947-4-1, FRLS internal wiring, with IP 54 protection and inbuilt short circuit protection. All as specified and directed at site. Make : Havells,/Legrand/L&T

1

-

-

... More
Supply and fixing new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65 flood light with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver type street light fitting 70 watt capacity LED, 120 lumens per watt type and including all accessories duly pre-wired, fixing on existing bracket with nut, bolts & washers as required at site for fixing of street light on LT pole/ wall complete including taking old street light fitting any type and description complete all as specified and directed. Make:- Havells/Crompton/Phillip

2

-

-

... More
Supply and fixing new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver type street light fitting 35 watt capacity LED, 120 lumens per watt type and including all accessories duly pre-wired, fixing on existing bracket with nut, bolts & washers as required at site for fixing of street light on LT pole/ wall complete including taking old street light fitting any type and description complete all as specified and directed. Make:Havells/Crompton/Phillips

2

-

-

... More
M&L in replacment of pin insulator porcelain type vitreous white brown including one galvanized mild steel spindle two galvanize iron washers and one galvanized iron nut 100 mm height, 65mm dia for 1100 V grade, complete all as specified and directed.

30

-

-

... More
M&L in replacment of shackle type porcelain vitreous white, brown including one galvanized mild steel straps, washers, bolts and nuts 100 mm height, 115 mm dia, section of strap 31 x 5 mm for 1100 V grade, complete all as specified and directed.

20

-

-

... More
M&L in repair for LT line PVC Spacers spiral type for the following :-

-

-

-

... More
(i) Spacer for two wire

40

-

-

... More
(ii) Spacer for three wire

50

-

-

... More
(iii) Spacer for four wire

50

-

-

... More
Dismantling/taking out old unserviceable LT of PCC/Steel poles after breaking the PCC foundation and clearing the site/premises and Supply and erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts , nuts and screw as specified of type 410 SP-31, 9 Meter long, including marking alternate yellow and black strips 30 cm height- total-5Nos with two coats of aluminium paint over a coat of zinc chrome primer above embedded portion at GL, complete all as specified and directed. (Note. Earth work and PCC for foundation channels, clamps, nuts and bolts to be measured and paid for separately)

4

-

-

... More
Dismantling of ACSR conductor, service feeder or distribution spans complete all as directed.

1.5

-

-

... More
Supplying, Stringing, Tightening, Fixing & connecting ACSR conductor of any size for over Head LT Line including aluminium binding wire or aluminium tape of suitable type clamps/connector or other jointing material complete all as specified and directed by EIC.

1.5

-

-

... More
M & L for galvanised steel wire 4 mm dia to be stringed as continuous earthing wire on over head LT lines complete all as directed incl taking down the old rusted earth wire.

1.5

-

-

... More
Dismantling cross-arms of M.S. channel or angle sections etc. complete all as specified.

1.5

-

-

... More
M&L for cross arms, bracing supports clamps and back plate fabricated from structural steel section including bolts, nuts, washers and welding, bending, cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint all as specified and directed by EIC.

1.5

-

-

... More
Supply and fixing in repairs stay assembly for LT Pole comprising of 7/3.15mm galvanized steel stranded stay wire of required length fixed to pole with and including clamps fabricated out of MS Clamps 50 x 6 mm flat iron including nuts, bolts and washers, MS galvanized stay bow 14mm dia 400mm long galvanized steel stay rod 16mm dia, 1800mm long with ratchet type nuts & bolts and stay plate, galvanized thimble 02 Nos, loop insulators 65mm x90mm clearance dia of hole 16mm all as specified and shown in electrical plate No. 1 of MES SSR including all necessary excavation and earth work, PCC (1:3:6) type C-2 using 40mm graded stone aggregate ,embedded block and disposal of surplus soil to a distance not exceeding 50mtr complete all as specified and directed by EIC.

3

-

-

... More
Earthing complete with galvanized steel earth plate electrodes 60x60x6 mm thick buried directly in ground eath (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to GI wire 4mm by means of bolt nuts check nuts and washers of galvnised iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I connected to earth test point as specified as specified and testing on completion including provision of 20 mm dia light grade pipe & watering pipe shall be 15 mm bore meadium grade including all excavation & earth work in any type of soil incl PCC for pit (1:3:6) type C-1 with RCC cover in PCC(1:2:4) including chrcoal, salt & funnel GI pipe 20 mm dia light grade up to to 7.5 mtr length ,all as directed at site.

8

-

-

... More
Repairs to existing stay assembly including tightening of stay wire, , shifting of clamps fixed to pole or by repairing to PCC coping by breaking and making new with PCC 1:2:4 type B-1 using 20 mm graded stone aggregate complete all as specified and directed at site .

4

-

-

... More
S & as in replacement of selector switch suitable for capacitor bank including all connecting/joining materials as required complete all as specified and directed.

8

-

-

... More
Material and labour in replacement of unserviceable can type resin filled (Alpx3) capacitors with built-in terminal connectors on top and mounting stud on the bottom heavy duty 440 V Un all as per existing type suitable for APFC panels, 3 phase, 415 V, 50 Hz sysytem of any capapcity. make : Legrand/Epcos/Universal

-

-

-

... More
(i)      25 KVAr

1

-

-

... More
(ii)     15 KVAr

1

-

-

... More
(iii) 10 KVAr

1

-

-

... More
(iv) 5 KVAr

2

-

-

... More
Material and labour in replacement of unserviceable digital power factor controller 4/6 step type with provision of manual and automatic mode operation conforms to IEC 61010-1, high accuracy, IP 41 terminals with manual and automatic mode ooperation all as per existing type suitable for APFC panels, 3 phase, 415 V, 50 Hz sysytem of any capapcity. make.: Legrand/Havells/L&T

2

-

-

... More
Material and labour in replacement of unserviceable capacitor switching unit capcitor duty contactor consisting of mounting block and contactors, for switching capacitors, suitable to be installed directly on 3 pole, 9 to 40 A contactors all as per existing type suitable for APFC panels, 3 phase, 415 V, 50 Hz sysytem of any capapcity. make : Legrand CTX3-series equivalent in Havells/L&T

4

-

-

... More
Material and labour in replacement of unserviceable capacitor switching unit capcitor duty contactor consisting of mounting block and contactors, for switching capacitors, suitable to be installed directly on 3 pole, 50 to 65 A contactors all as per existing type suitable for APFC panels, 3 phase, 415 V, 50 Hz sysytem of any capapcity. make : Legrand CTX3-series equivalent in Havells/L&T

4

-

-

... More
Material and labour in replacement of unserviceable three pole MCB 32 Amp all as per existing make suitable for APFC panels, 3 phase, 415 V, 50 Hz sysytem of any capapcity. make : Legrand DX3 cat part No. 4087 65 or equivalent in Havells /L&T

5

-

-

... More
Material and labour in replacement of unserviceable three pole MCCB 160 Amp all as per existing make suitable for APFC panels, 3 phase, 415 V, 36 KA, 50 Hz sysytem of any capapcity. make : Legrand DPX3 250 cat part No. 42037or equivalent in Havells/L&T

1

-

-

... More
Supply & fixing in replacement panel mounting cubicle type switch disconnector fuse three pole & neutral,32 A, 50 hz, 415 V (with bolted type fuse) complete all as specified and directed at site.

2

-

-

... More
Supply & fixing in replacement panel mounting cubicle type switch disconnector fuse three pole & neutral, 63 A, 50 hz, 415 V (with bolted type fuse) complete all as specified and directed at site.

2

-

-

... More
Supply & fixing in replacement panel mounting cubicle type switch disconnector fuse three pole & neutral,100 A, 50 hz, 415 V (with bolted type fuse) complete all as specified and directed at site.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.