Military Engineer Services Tender

View complete overview of Uttarakhand MES Tender

Military Engineer Services - MES Tender

Works
Energy, Oil and Gas
Eprocure
Opening Date21 Nov 2024
Closing Date21 Dec 2024
Tender Amount₹ 3,72,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling of cross arms, fabricated from Ms structural section of any type and size, duly bolted from existing position and keeping at side for repair/replacement as directed.

10.65

-

-

... More
Dismantling of existing stay assembly any type/size from its stay rod, cutting stay rods (above ground portion) dismantling MS clamps, nuts, bolts, stay bow, loop insulators, stay wire etc complete all as specified and directed.

10

-

-

... More
Dismantling/taking out insulator of any size/type from existing electric O/H lines all as specified and directed.

737

-

-

... More
Dismantling/taking out gang operated switch of any size/type from existing electric HT lines incl insulators and operating mechanism all as specified and directed.

4

-

-

... More
M & L for PVC underground cable XLPE insulated screend, PVC bedded, galvanised steel strip or wire armoured, electric power cables (Heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 95 sqmm 3 Core all as specified & directed.

8800

-

-

... More
M & L for cable jointing kit for 11 KV (Earthed) grade cable for out door termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm.

36

-

-

... More
M&L cable straight through joint box type suitable for 11 KV U/G XLPE screened PVC bedded GI Strip or wire armoured cable size 50 sqmm to 95 Sqmm 3 core and conforming as per IS 13573 OF 1992, cold shrinkable, connected to electrical system with and including cable pieces of suitable size length, and the tap vice type and one indicator plate for indication of joint above ground level compelete all as specified and directed.

5

-

-

... More
Supply, insallation commissioning and testing HT 11 KV out door type gang operated air break switch triple pole suitable for vertical mounting complete with MS channel of size 100x50 mm with suitable clamps MS bolts, nuts washers with operating mechanism worked from ground level, for current rating 200 amps complete with locking arrangement drop out fuse unit type carries and fuse element of required capacity having it insulation and switch having 11 KV 3 phase including connecting with OH & HT UG cable all as specified.

4

-

-

... More
S&F HT feeder pillar box outdoor type 11 KV with one incoming and three outgoing and made out of 3mm thick CRCA sheet weather proof with ventilation and wire mesh CPRI approved complete with copper busbar of 400 Amps rating on and including 11 KV HT insulators and double shutter one side extendable and back side with shuttered, locking arrangement on and including angle angle iron frame made of MS angle 75x75x6 mm MS angle and 3.0 mm thick sheet metal cladding earthing nut bolt and with removable cable gland plat for individual cable etc. complete all as specified and directed.

5

-

-

... More
Supply, Installation, testing, and commissioning of 11KV Non-Extensible Outdoor duty (IP54 enclosure) SF6 gas insulated 3-way motor operated Ring Main Unit comprising of 2nos. 630Amps Load Break Switches and 1no. 630Amps Vacuum Circuit Breaker, cable termination from the front, breaking capacity 21KA/3sec (Internal Arc Classification ALF-R 21kA-1sec both for tank and cable box as per IEC IEC 62271-200), enclosed in robotically welded stainless steel tank having IP67 Degree of Protection, leak rate of SF6 gas less than 0.1% and tested as per IEC 60056/60694/60298. The switchgear shall accommodate all the 4 modules in one tank. Protection CTs should be ring core type. Cable bushings should be replacable at site. Make of RMU should only be: SIEMENS (8DJH-ST)/ SCHNEIDER (FBX)/ Equivalent in ABB). NOTE:- Others details:- System Particulars: (1)Nominal System Voltage : 11kV. (2) Voltage variation on supply side : 10 % (3) Corresponding Highest System Voltage: 12kV. (4) Frequency : 50 Hz with  3 % tolerance (5) Transient condition : -20 % or + 10 % combined variation of Voltage and frequency. (6 )Number of Phase : 3 Phases. (7) Neutral earthling : Solidly earthed. (8) Fault level (minimum) kA /Sec : 21/3). 9) Lightning Impulse Withstand Voltage (kVp) : 75 (10) One minute dry/wet power frequency withstand voltage primary (kV rms) : 28KV (11) Rated Dynamic Withstand Current for 1 second duration (kAp) : 52.5KA (12) All bus bars used in the RMU panel must be of copper type CONTD...

4

-

-

... More
Applicable Standards: a) The design, manufacture and performance of the Ring Main Units shall comply with all currently applicable statutes, regulations and safety codes.Nothing in this specification shall be construed to relieve the bidder off his responsibilities. b) Unless otherwise specified, the Ring Main Units offered shall conform to the latest applicable, IEC 62271-100, IEC 62271-200. All live parts, bus bars, shall preferably be enclosed in one tank to avoid multiple inter connections & sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank Grade SS304 of minimum 2.5 mm thickness.The RMU shall be type tested for internal arc test of 21KA/1 sec AFLR as per IEC62271-200. The outer enclosure shall cover the full length of the switch gear, to ensure IP54 protection for full door covering of complete switchgear. The protection relay shall be for 3 OC + 1EF (IDMT Type) , MODBUS communication along with RS 485 Port . RMU and Vaccum Interruptor shall be of same make. All the mechanical bushings should be replacable at site, to avoid dismantling RMU from site and carrying to OEM factory for rectification for the minor gas leakages from mechanical bushing, this is operational & maintenane point, cannot be deviated. No additional plate/ accessories to be add to achieve Internal Arc of the Cable of 21kA-1sec, in the able box camber. RMUs should be manufactured, inspected and invoiced from the OEM factory only; no licensee partner manufactered RMU is exceptable. SERVICE CONDITIONS The SF6 gas filled 11 kV, 630 Amps, non-extensible type, Outdoor, SCADA compatible Motorized Ring Main Unit with Vacuum Circuit Breaker to be supplied against this specification shall be suitable for satisfactory continuous operation under the following tropical conditions, design ambient temperat+A1ure (Degree C) 40 as per IEC. The unit shall include the following with all necessary standard fitting as required at site: a) Vacuum Circuit Breaker 12kV 630Amps 21kA-3sec and fault making type Earthing Switch with micro-processor based selfpowered 3O/C + 1E/F relay fitted with fixed type voltage indicator device as per IEC 61958. Protection CTs suitable ratio 2.5VA burden (CT ratio shall be confirmed at time of drawing approval).-1No. b) Load Break Switch 12kV 630Amps 21kA-3sec with copper bus Bar and earth switch fitted with fixed type voltage indicator device as per IEC -2 Nos. Note: Standard mano meter -01 for each tank, Operating handle - 01, cable clamping provision (standard)-01/for every cable entry suitable for 1RX3C cable upto 300Sqmm, Operation and maintenance manual - 01, RMU Foundation (Earth Work and PCC works) for placing RMU on plinth is deemed to be included in the cost quoted. Height of plinth should not be less than 0.5 mtrs from ground level.

-

-

-

... More
Supply and erecting in true vertical position steel tubuler poles 11 meter long complete with M S base plate , MS pole cap, bolts nuts & screw as specified type 410 SP-55 (11.0 meter long) with and including painting of poles with black bitumenous paint throughout the length internally and outside upto planting depth and remaining portion 2 coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed

8

-

-

... More
Supply and erecting in true vertical position steel tubuler poles 11 meter long complete with M S base plate , MS pole cap, bolts nuts & screw as specified type 410 SP-55 (11.0 meter long) with and including painting of poles with black bitumenous paint throughout the length internally and outside upto planting depth and remaining portion 2 coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed

8

-

-

... More
M & L for Anti-climbing device,spikes type fabricated out of M.S bars (round, square and flat) including nut, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified

1

-

-

... More
S & F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in red signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for HT 11 KV, 25x20cm size all as specified and directed.

150

-

-

... More
M&L for MS cross arms bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts and washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.

1.76

-

-

... More
Supply and fixed GI strip 32x6mm thick as earthing lead.

45

-

-

... More
M & L galvanised steel water tubing 'light grade' 100mm bore with all fittings laid under the roads, drains, culverts and fixed on poles etc complete all as specified and directed .

120

-

-

... More
M & L for Lightning Arrestors 11000 Volts Expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Ampere complete incl taking down old unsv LAs all as specified and directed.

8

-

-

... More
Supply and laying un-reinforced precast concrete cable cover class HV type I flat of size 300mm x 180mm x 40mm all as specified factory made ISI marked.

33333

-

-

... More
Supply and fixing HT cable/route indicator cast iron of suitable size along HT cable trench including planting in ground with PCC complete all as specified and directed.

1550

-

-

... More
Supply and erecting in true vertical position steel tubuler poles 9 meter long complete with M S base plate , MS pole cap, bolts nuts & screw as specified type 410 SP-31 (9.0 meter long) with and including painting of poles with black bitumenous paint throughout the length internally and outside upto planting depth and remaining portion 2 coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed

16

-

-

... More
Supply, laying, jointing and commissioning LT XLPE 1100 volts grade heavy duty cable PVC insulated, stranded aluminium conductor served with inner sheathing of PVC tape, armoured with GI steel or tape and over all PVC sheathing laid in trenches, floor through pipes,induct, on pole and roads etc of following sizes :- (a) 400 Sqmm 3.5 core

300

-

-

... More
All as per item No 24 above but 300 Sqmm 3.5 core

400

-

-

... More
All as per item No 24 above but 185 Sqmm 3.5 core

600

-

-

... More
All as per item No 24 above but 150 Sqmm 3.5 core

1200

-

-

... More
All as per item No 24 above but120 Sqmm 3.5 core

2000

-

-

... More
All as per item No 24 above but 95 Sqmm 3.5 core

1450

-

-

... More
All as per item No 24 above but 70 Sqmm 3.5 core

850

-

-

... More
All as per item No 24 above but 50 Sqmm 3.5 core

1000

-

-

... More
All as per item No 24 above but 16 Sqmm 2 core

5000

-

-

... More
M&L for GI pipe light grade with all fittings fixed to pole and laid to floor/ground for mechanical protection of cable of the following sizes :- (a) 80mm bore

120

-

-

... More
All as per item No 33 above but 50mm bore

280

-

-

... More
All as per item No 33 above but 40mm bore

370

-

-

... More
S & F MCCB 415 Volts, 4 pole, 16 KA, 100 Ampere complete incl taking down old us MCCB all as specified and directed

6

-

-

... More
S & F MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA complete incl taking down old us MCCB all as specified and directed NOTE: Make and model of MCCB shall be as per sample/site requirement before purchasing material contractor shall take approval from Engr-in-Charge and if any necessary alteration work required in panel for fixing of mccb contractor have to carry out in quoted rate.

5

-

-

... More
All as per item No 37 here in before but cap 250 Amp,36 KA

5

-

-

... More
All as per item No 37 here in before but cap 350 Amp,36 KA

2

-

-

... More
All as per item No 37 here in before but cap 400 Amp,36 KA

2

-

-

... More
All as per item No 37 here in before but cap 630 Amp,50 KA

1

-

-

... More
Dismantling of existing MCCBs of any type and size from existing panels/sheet enclosures all as specified and directed

21

-

-

... More
Supply, fabricating and fixing of sheet metal enclosure for bus bars made of 16 gauge MS sheet outdoor type of suitable size (1000x800x650mm) with three nos 300 Amp rated aluminium busbar and one number 250 Amp aluminium busbar with provn for terminals for connecting outgoing cables on bus bar for distribution on porcelain insulators for neutral link double door type with locking arrangement and holes of required size for cable in and out complete with MS angle iron frame of size 40 x 40 x 5mm with nut/bolts and PCC plateform work including painting with two coat of synthetic enamelled paint over one coat of red oxide/ primer complete all as specified and directed at site.

12

-

-

... More
Supply, fabricating and fixing of sheet metal enclosure for bus bars made of 16 gauge MS sheet outdoor type of suitable size (1000x800x650mm) with three nos 200 Amp rated aluminium busbar and one number 150 Amp aluminium busbar with provn for terminals for connecting outgoing cables on bus bar for distribution, on porcelain insulators for neutral link double door type with locking arrangement & holes of required size for cable in and out complete with MS angle iron frame of size 25 x 25 x 5mm with nut/bolts and PCC plateform work including painting with two coat of synthetic enameelled paint over one coat of red oxide/ primer complete all as specified and directed at site.

12

-

-

... More
Supply, fabricating and fixing of sheet metal enclosure for bus bars made of 16 gauge MS sheet outdoor type of suitable size (1000x800x650mm) with three nos 100 Amp rated aluminium busbar and one number 100 Amp aluminium busbar with provn for terminals for connecting outgoing cables on bus bar for distribution, on porcelain insulators for neutral link double door type with locking arrangement & holes of required size for cable in and out complete with MS angle iron frame of size 25 x 25 x 5mm with nut/bolts and PCC plateform work including painting with two coat of synthetic enameelled paint over one coat of red oxide/ primer complete all as specified and directed at site.

6

-

-

... More
Supply and fix junction box made out of high quality thermoplastic polycarbonate enclosure with IP 65 degree protection, weather proof, corrosion proof, dust proof, insulated and shock proof, fire retardant non toxic material with internally embedded gasket with 10 Amp MCB and 4 nos terminal of size 200x160x98 mm of make hensel or equivalent make of sintex/universal

145

-

-

... More
Supply and Fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT,440 V, 20x15cm size complete all as specified and directed.

250

-

-

... More
Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified), LT feeder pillar box (KIOSK), outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bars suitable Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys, internal wiring 2.5 Sqmm with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size incl the provision of space to accommodate the under mentioned items incl taking out U/s one and making connection with existing LT cables including the following:- (a) Incoming (i) MCCB 4 pole, 415 volts AC grade, 400 Amps rating and 36 KA rupturing capacity complete - 01 No (ii) Voltmeter 0-500 volts, square, 144 mm, flush pattern with 3 way rotary selector switch - 01 No (iii) Ammeter size 144 mm, square dial, flush pattern having dual range 1000 amps with three way rotary selector switch with suitable size of LT's 01 No (iv) Indicating lamps : ­­ 01 set of three (b) Outgoing (i) MCCB 4 pole, 415 volts AC grade,100 Amps rating and 25 KA rupturing capacity complete - 02 No (ii) MCCB 4 pole, 415 volts AC grade,200 Amps rating and 25 KA rupturing capacity complete - 02 No (iii) MCCB 4 pole, 415 volts AC grade,63 Amps rating and 25 KA rupturing capacity complete - 02 No (iv) MCB SPN 230 volts AC grade,C Curve, 40 Amps rating complete - 03 No (v) Timer Switch (daily with IP 53 box) - 01 Nos (c) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone aggregate , 15 cm thick in foundation, brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45cm above the nearest road level. Note :- (i) All out going feeders shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.

4

-

-

... More
Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified), LT feeder pillar box (KIOSK), outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bars suitable Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys, internal wiring 2.5 Sqmm with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size incl the provision of space to accommodate the under mentioned items incl taking out U/s one and making connection with existing LT cables including the following:- (a) Incoming copper bus bar of capacity 1200 Amp for phase and 600 Amps for neutral. 01 Set (i) ACB 4 Pole, 415 V, with microprocessor based alongwith Spreader terminals with adjustable thermal and magnetic setting Draw out type of capacity 630 Amps - 01 No (ii) Voltmeter 0-500 volts, square, 144 mm, flush pattern with 3 way rotary selector switch - 01 No (iii) Ammeter size 144 mm, square dial, flush pattern having dual range 1000 amps with three way rotary selector switch with suitable size of LT's 01 No (iv) Indicating lamps : ­­ 01 set of three (b) Outgoing (i) MCCB 4 pole, 415 volts AC grade,250 Amps rating and 36 KA rupturing capacity complete - 02 No (ii) MCCB 4 pole, 415 volts AC grade,200 Amps rating and 36 KA rupturing capacity complete - 02 No (iii) MCCB 4 pole, 415 volts AC grade,350 Amps rating and 36 KA rupturing capacity complete - 01 No (iv) MCCB 4 pole, 415 volts AC grade,C Curve, 160 Amps rating complete - 02 No (v) Timer Switch (daily with IP 53 box) - 01 Nos (c) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone aggregate , 15 cm thick in foundation, brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45cm above the nearest road level. Note :- (i) All out going feeders shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.

1

-

-

... More
S&F synthetic insulating mat near electric installations of size 2m x 1 mX 2.5 mm for voltage upto 11 KV as specified and directed.

8

-

-

... More
All as per item no 40 above but of size 2m x lm x 2 mm for voltage upto 3.3 KV

7

-

-

... More
Supply, fabricating and fixing of sheet metal encluser made of 16 gauge MS sheet outdoor type of suitable size including fixing of MCCB of cap 200 Amp, 415 Volt,50Hz, 4 pole, 36 KA, AC supply with 300 Amp rated aluminium busbar on porcelain insulators for neutral link double door type with locking arrangement complete with MS angle iron frame of size 25 x 25 x 5mm with nut/bolts and PCC plateform work including painting with two coat of synthetic enameelled paint over one coat of red oxide/ primer complete all as specified and directed at site.

10

-

-

... More
Supply, install, test and commission feeder pillar box out door type complete with weather protected top canopy front and rear operated twin leaf doors and cable allay ,with locking arrangement made out of 3 mm thick sheet steel duly treated with powder coated finish, copper bus bars in enclosed chamber complete with MC100 pedastal for grounting, PCC pedastal, rubber linings for doors with including foundation complete with the following :- (i)Copper bus bars of capacity 300 Amps for three phases and 200 Amps for neutral . (ii) MCCB 4 P 200 A with Thermal Magnetic range. Braking capacity 25 KA (for incoming) - 1 No. (iii) b) MCCB 4Pole 100A C Curve - 02 Nos(Outgoing) (iv) MCCB 4pole 63A C Curve - 01 Nos(Outgoing) (v) MCB SPN 63A C Curve - 02 Nos(Outgoing) (vi) Voltmeter Digital 0-500 Volts -01 No with selector switch (vii) Ammeter Digital 01 No with CTs and selector switch (viii) Timer Switch (daily with IP 53 box) (ix) Phase indication lamp(RYB) - 01 set

6

-

-

... More
Supply, install, test and commission feeder pillar box out door type complete with weather protected top canopy front and rear operated twin leaf doors and cable allay ,with locking arrangement made out of 3 mm thick sheet steel duly treated with powder coated finish, copper bus bars in enclosed chamber complete with MC100 pedastal for grounting, PCC pedastal, rubber linings for doors with including foundation complete with the following :- (i) Copper bus bars of capacity 200 Amps for three phases and 150 Amps for neutral . (ii) MCCB 4 P 125 A with suitable release range. Braking capacity 25 KA (for incoming) - 1 No. (iii) MCCB 4Pole 100 A C Curve - 02 Nos(Outgoing) (iv) MCCB 4Pole 63 A C Curve - 03 Nos(Outgoing) (v) MCB SPN 40A C Curve - 03 Nos(Outgoing) (vi) Voltmeter Digital 0-500 Volts -01 No with selector switch (vii) Ammeter Digital 01 No with CTs and selector switch (viii) Timer Switch (daily with IP 53 box) (viii) Phase indication lamp(RYB) - 01 set

4

-

-

... More
M&L for earthing complete with galvanised steel, earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in in electrical plate No 5 on page 19-49 of MES schedule 1991 Part I connected to main switch board /main DBs/ earthing test point Including all necessary excavation and earth work in hard/ dense soil common salt and charcoal dust mixed and packed 150 mm thick all-round the GI earth plate, watering pipe 20 mm dia G I medium grade . GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150C/C both ways and pit/ chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 25mm dia light grade up to 7.5m from complete all as specified ,indicated on electrical plate No 5 and as directed incl testing on completion. NOTE: ( i ) Earth lead beyond 7.5 m from electrode to earth terminal GI pipe light grade 25mm/40mmdia for protection against mechanical damage to lead shall be measured separately (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost.

14

-

-

... More
M & L for earthing complete with galvanised steel, earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 4.5mtr below ground level) with top edge of the plate not less than 3.75 mtr below normalground level connected to galvanised earth trip as earthing lead (32x6mm) by means of bolts nuts check nuts and washer of galvanised iron/steel connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate wetering pipe 20mm dia GI medium grade GI sheet 0.63mm thick funnel , wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150 c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 40mm dia light grade upto 7.5 mtr from electrode and engraving of earth marking on near by structure/painting of earth results etc, complete all as specified indicated on electrical plate No-1 SSR Part_I 2009 Page No-479 and as directed including testing on completion. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost.

30

-

-

... More
Excavation in trenches in hard/dense soil not exc 1.5mtrs wide and not exc. 1.5m in depth for laying cables and getting out incl jointing bottom surface to the reqd level/slope etc complete all as specified and directed.

4792.82

-

-

... More
Return filling in incl spreading, leveling,watering and well ramming in layers not exc 25 cm in hard/dense soil all as specified and directed.

2724.91

-

-

... More
Removing excavated material to a distance not exc 15 mtr and deposited where directed at a level not exc 1.5 mtrs above the starting point all as specified and directed.

2067.91

-

-

... More
M&L for laying of fine river sand, free from sharp material for cable cushioning in trenches all as specified and directed.

1134

-

-

... More
M&L for brick protection covers laid over cables of sub class'B' bricks old size (230X115X75)mm all as specified and directed.

75

-

-

... More
Excavation in trenches in hard/dense soil not exc 1.5 mtrs wide and exc 1.5 m in depth for post holes, laying cables and getting out incl jointing bottom surface to the reqd level/slope etc complete all as specified and directed.

1.3

-

-

... More
M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of steel tubular pole incl form work complete all as specified and directed.

12.94

-

-

... More
M & L for PCC (1: 4:8 ) type D-2 using 40mm graded stone aggregate as in bottom of pit for bed concrete of steel tubular pole incl form work complete all as specified and directed.

1.3

-

-

... More
M & L for PCC ( 1:2:4) type B-1 using 20mm graded stone aggregate as in coping including all form work complete all as specified and directed.

2.43

-

-

... More
Supply,installing,commissioning and testing of cable fault locating instruments suitable to locate the pin point in LT/HT cable 1100 V to 33 KV cable and route tracing instruments to trace the route of burried cable including the eqpts shall be suitable for testing and pin pointing conductor and insulation fault of low and high resistance, intermittent or flashing nature in PILC, PVC and XLPE Low tension & High tension , under ground power cables up to 11 KV . The cable testing and fault locating kit shall be consist of following equipments: (a) Digital Fault locator - Pre location of faults in cables shall be carried out using various fault location method built in the eqpts with the help of highly sophisticated menu driven microprocessor based digital fault locator. The eqpt should have fully menu- guided , Display should be colour LCD , Operation up to 6 hrs in battery mode and supported with pulse Echo method and Implse current method . (b) Surge Generator : The surge generator shall be capable of providing repetitive surges at voltage variable from zero to the violtage mentioned below with output of 1000J (Optionally 2000J). An interlock to be provided which which ensures that instrument can switched on , only if the special cable supplied has been connected to the output sockets. The unit should be provided with automatic dischage device. Tech data of surge Generator- Output Voltage: 0-32 KV continously variable Surge capacity - 1000 J (optional 2000j) with Internal mounted capacitors Timer - 10 pulses per mmin , 20 pulses per min for automatic surging features for DC pressure testing unit: Continously adjustable output voltage, HV Zero interlock , S/c protection by internal current limitattion , Voltage indication up to 32 KV , Discharge Device , Thermal over current switch off Filter unit : A suitable coupling unit to enable fault location as per pulse echo method and impulse current method should be provided. The unit should incorporate discharge device so that high voltage leads are discharged after appx 3 sec , after switching off the main instrument. The activation of the grounding unit should be acknowledged audibly . The dischage device should be activated automatically in -case of power breakdown or an interruption.

1

-

-

... More
Pin - pointing set : The pin-pointing set is to be used in conjuction wiith above surge generator and should be capable of pin -pointing acoustic disturbances created by the dissipation of energy from surge generator at the the fault. Seismic disturbances picked up should be indicated to the operator both audibly on the head phone and visually on a display meter . The unit should be able to measuresacoustic propagation time wherein time difference between magnetic and acoustic pulse can be measured and evaluated. Insrument offfered should also incorporate a magnetic detector with separate amplifier . This should pick up and display caused by each current impluses . The receiver should be light weight with integrated batteries. The unit should switch off automatically in-case odf disconnection from ground microphone. The unit shpould be provided with suitable ground microphone whhich can filter out noises for accurate fault pin-pointing. sheath fault location with two earth probes according to the step voltage method should also be possible The eqpt should have following features:- (i) Integrated loudspeaker (ii) Water resistant design (iii) Large illuminated LCD display (iv) Adjustable filter to optimise acoustic signakl (v) Accurate route tracing (vi) Light weight (vii) Acoustic pin-pointing ccombined with propagation time measurement (viii) Route tracing (ix) Depth determination

-

-

-

... More
Technical Data Receiving frequency : 50 Hz -10 kHz, 815 Hz , 2 kHZ, 10 kHZ + 2 adjustable frequencies 50 Hz - 10 kHZ Filter- Digital Passive reception - 50/60 Hz mains signal Amplification ; 0- 38 dB Propagation velocity range : 0-96ms Operating Temp - -20 Degree centigate .... + 55 degree centigrate Protection - IP54 Power supply - 4x1.5 V cel (IEC LR6) Battery life ( Normal operation) - over 50h Cables All cables reqd for operation of cable testing system shall be mounted on drums with take out facility. The cable drum should be proided with screw terminal for protective earth cconnection with a monitoring switch so that putting in tgo operatioin of the sdystem is only possible when the protective earth lead is conected on the system side. The particulars of cables required are indicated belows: Earthing Cable : 25 M earthing cable 16 sq mm multistranded flexible copper with rubberised insulation to connect. Power supply cable : 25 m three core cable for connection of equipment to mains ( max 16 A) HV cable: 25 m , co-axial HV cable to serve as connection between cable fault locator and the cable to be tested. The ross section of core andshied should be 6 sq mm . The lead should be suitable for an operating voltage up to 70 KV DC . EPR insulation should be used , so that cable can remain flexible even in extreme cold condition.

-

-

-

... More
Mounting The eqpt should be mounted on zink coated suitable base frame wheels so that eqpt can be easily transported in a vehicle, and once inserted in a vehicle it can be locked safe for transport. Complete eqpt should be provided as a single system. Safety measures The instrument should have a built -in automatic discharge feature as per which a cable (installatiion) has to be safely discharge after a high voltage set. An emergency button on surge generato shall be provided to disconnect all equipments. All equipments shall be discharge on supply failure or disconnection of the unit. Make - CSD Instruments , Megger, Techno, Telemetrics. Note : The contractor will train two persons which has to be nominated by GE/ Engr-in-charge about all functions of fault locator machine and one person should be deployed at their ends to attend any problems which occurs in machine, and the individual will be present in office/site within days after intimation from office till six month after completion of work.

-

-

-

... More
S&F epoxy LT end joints of size 6 sqmm to 16 sqmm

10

-

-

... More
S&F epoxy LT end joints of size 25 sqmm to 50 sqmm

8

-

-

... More
S&F epoxy LT end joints of size 70 sqmm to 95 sqmm

8

-

-

... More
S&F epoxy LT end joints of size 120 sqmm to 150 sqmm

6

-

-

... More
S&F epoxy LT end joints of size 185 sqmm to 240 sqmm

6

-

-

... More
S&F epoxy LT end joints of size 300 sqmm to 400 sqmm

4

-

-

... More
S&F epoxy LT straight through joints of size 6 sqmm to 16 sqmm

4

-

-

... More
S&F epoxy LT straight through joints of size 25 sqmm to 50 sqmm

4

-

-

... More
S&F epoxy LT straight through joints of size 70 sqmm to 95 sqmm

3

-

-

... More
S&F epoxy LT straight through joints of size 120 sqmm to 150 sqmm

3

-

-

... More
S&F epoxy LT straight through joints of size 185 sqmm to 240 sqmm

2

-

-

... More
S&F epoxy LT straight through joints of size 300 sqmm to 400 sqmm

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.