Military Engineer Services Tender

View complete overview of Uttarakhand MES Tender

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date24 May 2024
Closing Date15 Jun 2024
Tender Amount₹ 35,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
HIGH MAST SYSTEM MAKE : Approved Make Height of mast : 12.5 Meter No. of Section : Two Plate Thickness : Top - 3 MM, Bottom- 3 MM Material Construction : S355 Grade as per BS-EN10 025 Base dia and top diameter (A/F): Top : 100 mm Bottom : 360 mm Cross section of Mast : 20 side polygon Standard for Galvanisation : A per BS EN ISO 1461 Size of Opening door at base : 1200 x 250 mm Diameter of base plate : 520 mm Thickness of base plate : 25 mm Lighting protection finial : GI single spike of length 1200mm Max. wind speed : 44m/s as per IS 875 (Part III) Number of foundation bolts : 12 Nos PCD of foundation bolts : 445mm Type / diameter / length of foundation bolts : TS 600/30mm dia/ 850 mm long Contd........

-

-

-

... More
FOUNDATION DETAILS 1. Excavation dimensions 2800 x 2800 x 1500mm size 2. Lean Concrete 100 mm thick PCC ( 1:4:8) D2 (using 40mm graded Aggregate) 3. Matt bars 12mm dia TMT Bars @ 200C/C both ways in double layers 4. RCC (1: 1.5 : 3) 2600 X 2600 X300MM as in footing 5. RCC (1 : 1.5 : 3) 1000 X 1000 X 1400 MM (1100MM below GL and 300 mm above GL) 6. 8 Nos 16mm dia TMT Bars 4 at corners 4 at centres of pedastal col as main bar with 600mm long craking at bottom over matt bars 7. 16 Nos 12mm dia TMT main bars (4 Nos each at 4 side with 600mm long cranking at bottom over matt bars. 8. 10mm dia TMT bars @ 100mm C/C as Stirrups Contd......

-

-

-

... More
9. 300mm dia 850mm long foundation bolts 08 Nos inserted in to 16 mm thick anchoring plate 590mm dia at bottom with pointed galvanised nut one each at bottom and top of plate. 10. Foundaiton bolt min clearance 150mm above pedestal col to rest high mast base plate 25mm thick over the bolts. Galvanised nuts 01 number at bottom of base plate 2 Nos at top of base plate. Note : The unit rate is inclusive of necessary formwork, RFL removal of surplus earth, foundation concrete,external finishes and all other unforeseen items all as directed by Engr - in- Charge Contd......

-

-

-

... More
LUMINAIRES CARRIAGE Material of construction : 50 NB ERW Class B-M.S Pipe Diameter of carriage ring (mm) : 535 mm (ID) Construction : 06 Arm, Welded, 2 Sections Load carrying capacity : 08 Luminaire TRAILING CABLE Conductor : Copper, 5 core, 2.5 Sqmm Insulation : EPR insulated PCP scheathed No.of circuits per mast : One Contd.....

-

-

-

... More
WINCH / POWER TOOL Type /SWL of winch : Single gear, Double drum, SWL 500 Kg Method of Operation : Integral Motor Motor Capacity : 1.5 HP ( Including suitable starter) No of Speeds : 6 Pole, Single speed Torque Limitor : With Mechanical Tripping Facility STAINLESS STEEL WIRE ROPE Grade / construction : AISI 316, 7/19 Construction Number of Ropes : Two Continuous Diameter (mm) : SS304 grade, 6 mm Breaking load Capacity : 2350 Kg x 2

-

-

-

... More
Supply ,fixing ,commisioning and testing of LT feeder Panel outdoor type of suitable size made cubical type weather and vermin proof fixed and including PCC arrangement PCC 1:2:4 type B-2 using 40 mm graded stone aggregrate as in foundation of required/suitable size and as directed at site with angle iron frame of size40x40x5 mm 3 phase 4 wire 415 volts 50 Hz fabricated with MS sheet including two coats of synthetic enemeled paint over a coat of red oxide primer and keeping adequate working space inside the box and double door handle includng locking arrangement as directed before manufacturing the panel . The drawing of the feeder pillar box will be approved by Engr-in-Charge and the same having following electric controls: Incoming: (i) MCCB 63 Amps TPN 415 volts 50 Hz 16 KAconnected with required bus bar connections - 01 Nos (ii) Digital Voltmeter -01 , Digital Ampmeter-01, Indicating Lamp RYB- 01 set Outgoing: (i) MCB 40 Amps TPN 415 volts 50 Hz 16 KA - 02 Nos (ii) Three Phase Timer switch astronomical type with suitable contactors & Relay protection switches- 01 (iii) Auto manual sitch for timer opeartion mode. (iv) Push button switch assembly for lowering and raising with torque motor for light fittings structure.

5

-

-

... More
Supply and fixing LED flood light 150 Watt 230 Vols AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection with heat resistance & corrosion resistance die cast aluminium compact with surface mounting Diode (SMD) LED complete with driver equipped with toughened glass complete all as specified and as directed.

30

-

-

... More
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) with stranded aluminium conductor , 1100 volts grade of size 4 core 10 Sqmm complete all as specified and directed.

800

-

-

... More
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) with stranded aluminium conductor , 1100 volts grade of size 4 core 16 Sqmm complete all as specified and directed.

1100

-

-

... More
Supply and erection, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP 31 09 mtrs long Class -10 including painting of poles with two coats of synthetic enamel paint in red and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed by Engineer in charge. Note: PCC, Earth work and MS work and cross arms clamps etc will be measured and paid separately.

40

-

-

... More
Supply and fixing powder coated pressure die cast aluminium compact LED street light fitting of capacity 45 Watt heat resistance with lens,driver and surge protector upto 10 KV with IP 66 protection complete all as specified and as directed.

40

-

-

... More
M&L for earthing complete with galvanised or steel earth plate electrode of size 60cm x60cmx6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected galvanised earth lead wire 4.0 mm with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to arthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR(Pt-I)1991 complete all as specified and dirfected by Engineer-in-charge.

2

-

-

... More
M&L for earthing complete with galvanised or steel earth plate electrode of size 60cm x60cmx6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to strip 32x 6 mm size with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to arthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR(Pt-I)1991 complete all as specified and directed by Engineer-in-charge.

20

-

-

... More
Supply, fixing & connection of cable twin core PVC insulated and unsheathed solid copper conductor of size 1.50 Sqmm inside the steel tubular Poles for connection of street lights to Pole loop in loop out junction box with proper lugs/connectors complete all as specified and directed.

360

-

-

... More
Supply and fixing street light bracket made out of 40 mm dia GI pipe light grade of length upto 1.5 mtr bent to shape required with and including 2 Nos, 40 x 6 mm MS flat iron clamps with nuts, bolts, washer etc and applying one coat of aluminium paint to clamps complete all as specified and directed.

40

-

-

... More
Supply and fix loop-in loop-out junction box of size 30cmx25cmx20cm made of 1.6mm thick PVC sheet weather proof, dust and vermin proof with hinged door of locking arrangements and slanting cover on top with provision of aluminium busbar of size 25 x 2mm - 4 No fixed on insulator complete fixed on pole with and including suitable size MS flat iron clamps, nuts, bolts and washers, etc complete all as specified and directed.

40

-

-

... More
Supply, installation, testing & commissioning of Digital Astronomical timer control panel for street light of three phase Max load 12 KW complete with contractor rating 65/70 TP, MCB rating 63 Amp TPN ,digital astronomical type timer, relay switch and control wiring complete with auto ,manual and off selector switch complete all as specified and directed.

1

-

-

... More
Material and labour for PCC 1:3:6 type C-2,using stone aggregate 40mm graded as in foundation of stays and coping of poles including necessary form work where required and fair finish to the exposed surfaces all as specified & directed.

1.02

-

-

... More
Material and labour for PCC 1:4:8 type D-2, using stone aggregate 40mm graded as in foundation for electric poles and making of cable duct including necessary form work where required and fair finish to the exposed surfaces all as specified & directed.

38.4

-

-

... More
Excavation in trenches n. exc. 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of underground cable and for Steel tubular poles and getting out in any type soil complete all as specified and directed.

421.2

-

-

... More
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.

263.39

-

-

... More
Removing of excavated soil to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.

157.81

-

-

... More
M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed.

108.81

-

-

... More
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.

10.95

-

-

... More
S & F GI pipe light grade 40 mm bore for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed.

66

-

-

... More
Cutting of floor/wall/road/footpath for removal of LT U/G cable of any size/description and making good the same as per existing specification laying the new cable and all as specified & directed.

24

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.