Military Engineer Services Tender

View complete overview of Uttarakhand MES Tender

Military Engineer Services - MES Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date4 Sep 2024
Closing DateCancelled
Tender Amount₹ 8,63,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(e) Electric starter equipment :- The equipment with comprise the following:-(i) Maint free Battery duly initial charged as recommended by manufacture & Battery lead of adequate capacity. (ii) Starter motor (iii) Starter gearing (iv) Start/stop push button (vi) PCC foundation for DG set all as per manufacture recommendation or required at site or directed by Engineer-in-Charge. DG Set acoustic canopy shall be from OEM or of v) Alternator/Dynamo of suitable capacity to charge the batteries while DG set is running complete with auto cut all as per manufacture recommendations. (f)Accoustic Enclosure: Accoustic enclosure shall be designed to meet stringent MoEF/CPCB norms.It shall be made of CRCA sheets as per manufacturers colour shade and a structural /sheet metal base frame as per manufacturers colour shade.It shall be equipped with high quality noise absorbent and fire retardent grade acoustic insulation material foam complying to IS 8183, two point top lifting for easy handling at customer site, Air inlet louvers specially designed to operate at rated load,11 tank pretreatment process and UV resistant powder coating of all parts to withstand extreme environment ,fluids drain for lube oil and fuel,external fuel filling arrangement outside the enclosure. (g) The testing of DG set for continuouss 12 Hrs running shall be carried by officer detailed by accepting officer before issuing completion certificate to contractor. On load testing eqpt including diesel for continuous testing for 12 hours or above till full testing (satisfaction or directed by Engineer-in-Charge) will be arranged by the contractor.Generator load test shall be based on resistive load.

-

-

-

... More
Material and Labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR PT-I including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, GI lugs, complete in all respect, GI earth wire protected by 15 mm bore (Light grade) galvanized iron pipe and other end connected with main switch board or earthing test point as directed including proper lugs, including disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete all as specified and as directed by the Engineer in charge .Note:1. Earthing Installation shall be done in the presence of Engineer in charge.2. Earth resistance shall not exceed 1ohm.

4

-

-

... More
Excavation in trenches not exceeding 1.5 metres wide and not exceeding1.5 metres in depth and getting out in any type of soil complete all as specified and directed.

1.8

-

-

... More
Returning, filling in, including spreading , leveling , watering and well ramming in layer not exceeding 25cm each layer complete all as specified and directed.

0.97

-

-

... More
Removing excavated material not exceeding 50M and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.

0.83

-

-

... More
Sand filling in trenches for cable protection provided with layer 8cm deep before laying of cable and 15 cm after laying including spreading and leveling watering and well ramming in layer not exceeding 25mm thick complete all as specified and directed.

0.72

-

-

... More
Supply and laying in trenches Sub class ‘B’bricks well burnt locally available for covering to cable laid dry flat ,with width of brick perpendicular to the length of cable complete all as specified and as directed.

99

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core complete all as specified and directed.

40

-

-

... More
Supply and fix on load change over switch in sheet metal enclosure 100Amp four pole,modular type,positive isolation,door interlock and padlock facility confirming to IS/IEC 60947-3 complete all as specified and directed.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.