Military Engineer Services Tender

View complete overview of Uttarakhand MES Tender

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date1 Jan 2025
Closing Date22 Jan 2025
Tender Amount₹ 10,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR / REPLCEMENT OF STREET LIGHT AND CONNECTED WORKS AT GBS CAMP, MT CAMP, OTM ACCN AND CSD COMPLEX AT KOTDWARA UNDER AGE (I) LANSDOWNE.
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fix in repairs new LED street/security light fitting 45W housing made out of pressure die-cast aluminium alloy with toughned glass, IP-66 protection, working on 240 Volts , 50 HZ, consisting of reflective lens wired with appropriate driver PF0.98 having over voltage protection upto 440 volts, Surge protection level ≥ 10 KV, thermal short circuit protection THD 10% made up of long life LED chips (SMD) in modular with Ra70, and LED lumen efficiency 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiancy 110 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500° K including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volts grade from pole box to light or from overhead conductor to light complete all as specified and as directed by Engr-in-Charge. Note: (i) the firm has to give warranty for street light fittings including driver minimum for 03 years for any defects developed during the period. (ii) The contractor shall submit the third party LM 79 report from any NABL approved laboratory. (iii) The fitting should have BIS & CRS no

48

-

-

... More
Supply and fix in repairs new LED street/security light fitting 60W housing made out of pressure die-cast aluminium alloy with toughned glass, IP-66 protection, working on 240 Volts , 50 HZ, consisting of reflective lens wired with appropriate driver PF0.98 having over voltage protection upto 440 volts, Surge protection level ≥ 10 KV, thermal short circuit protection THD 10% made up of long life LED chips (SMD) in modular with Ra70, and LED lumen efficiency 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiancy 110 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500° K ncluding connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volts grade from pole box to light or from overhead conductor to light complete all as specified and as directed by Engr-in-Charge. Note: (i) the firm has to give warranty for street light fittings including driver minimum for 03 years for any defects developed during the period. (ii) The contractor shall submit the third party LM 79 report from any NABL approved laboratory. (iii) The fitting should have BIS & CRS no

11

-

-

... More
S & F Loop in and Loop out FRP rectangular SMC junction box (Pole Box) front openable hinged from side of size 240x130x110 mm suitable for outdoor installation weather proof having 4 pole cable connector (for cable in and out junction) fixed inside box with insulator support and 01 nos MCB SP 06 Amp fixed inside box complete for street light fitting with mS clamps 40x5 mm GI nuts, bolts and washers complete all as specified and directed.

10

-

-

... More
Supply and fix in repairs LED flood light fitting 120W/150W housing made out of pressure die-cast aluminium alloy with toughned glass, IP-66 protection, working on 240 Volts , 50 HZ, consisting of reflective lens wired with appropriate driver PF0.98 having over voltage protection upto 440 volts, Surge protection level ≥ 10 KV, thermal short circuit protection THD 10% made up of long life LED chips (SMD) in modular with Ra70, and LED lumen efficiency 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiancy 110 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500° K including fixed on pole of any type on existing angle iron with the help of nuts bolts washer including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volts grade from pole box to light or from overhead conductor to light complete all as specified and as directed by Engr-in-Charge. Note: (i) the firm has to give warranty for street light fittings including driver minimum for 03 years for any defects developed during the period. (ii) The contractor shall submit the third party LM 79 report from any NABL approved laboratory. (iii) The fitting should have BIS & CRS no

4

-

-

... More
Supply and fix in repairs LED flood light fitting 100W housing made out of pressure die-cast aluminium alloy with toughned glass, IP-66 protection, working on 90 Volts , 50 HZ, consisting of reflective lens wired with appropriate driver PF0.98 having over voltage protection upto 440 volts, Surge protection level ≥ 10 KV, thermal short circuit protection THD 10% made up of long life LED chips (SMD) in modular with Ra70, and LED lumen efficiency 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiancy 110 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500° K including fixed on pole of any type on existing angle iron with the help of nujts bolts washer including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volts grade from pole box to light or from overhead conductor to light complete all as specified and as directed by Engr-in-Charge. Note: (i) the firm has to give warranty for street light fittings including driver minimum for 03 years for any defects developed during the period. (ii) The contractor shall submit the third party LM 79 report from any NABL approved laboratory. (iii) The fitting should have BIS & CRS no

4

-

-

... More
Supply and Fixing in repair LED driver with PF0.95, input voltage 240 V AC, 50 Hz, input current 0.25 Amp AC, output voltage 42V-72V DC, output current 0.7A DC THD10%, line volatge 140 to 277 V, IP 20 protection as per IS:15885(part-II section 13) suitable for LED street light of 25 Watt to 45 Watt outdoor dry and damp application after taking down the street light from pole/wall and refixing the street light on pole/wall (Size of driver should be as per sample given by EIC) complete all as specified and directed.

21

-

-

... More
Supply and Fixing in repair LED driver with PF0.95, input voltage 240 V AC, 50 Hz, input current 1.6 Amp AC, output voltage 42V-72V DC, output current 0.7A DC THD10%, line voltage 140 to 277 V, IP 20 protection as per IS:15885(part-II section 13) suitable for LED street/Flood light of 50 W to 90Watt outdoor dry and damp application after taking down the street light from pole/wall and refixing the street light on pole/wall (Size of driver should be as per sample given by EIC) complete all as specified and directed.

21

-

-

... More
Excavation in trenches in any type of soil n.exc 1.5 m wide and n.exc 1.5 m in depth for poles,laying under ground electric cable and GI tubing (where provided for protection of cables), stay and getting out, trimming the sides, forming bottom surface to required level in any type of soil complete all specified and directed.

111.38

-

-

... More
Returning filling in any type of soil including spreading, levelling, watering and well ramming in layers n.exc 25cm each layer complete all as specified and directed.

63.82

-

-

... More
Removal of excavated surplus any type of soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.

47.55

-

-

... More
M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. Note:- Punned (consolidated ) thicness of sand will be measured and paid.

35.64

-

-

... More
M&L for burnt bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed.

3.82

-

-

... More
M & L, PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in mass concrete/foundation complete all as specified and directed.

2.91

-

-

... More
M & L PCC 1:4:8, type D2, ( using 40mm graded stone aggegate) as in foundation and posts including caps and bases complete all as specified as directed.

0.3

-

-

... More
S&F garden lithts integral decorative LED bollard with opal acrylic with IP-65 protection including connector to connect the cable and all necessary accessories all as specified and directed. Note:- Necessary excavation and PCC work for Bollard lights fittings deemed to be inculded in quouted rates.

25

-

-

... More
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.

25

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.00 sq mm 2 core complete as specified and directed.

250

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.