Military Engineer Services Tender
View complete overview of Uttarakhand MES Tender
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date30 Nov 2024
Closing Soon28 Dec 2024
Tender Amount₹ 47,90,000
Costs
EMD
₹ 95,800Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_686466_1Tender No
9996/DDN(P)/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supply & filling the new transformer oil in bealed container having dielctric strength not less then 50 KV for topping up to required level of 11 KVA transformer complete all as specified and directed.
200
-
-
... More
Supply and fix transformer silica gel breathers transparent of standard size suitable for 250/400 KVA transformers 11 /0.433 KV volts cast alluminium transparent type including removing the existing unserviceable one complete all as specified and directed.
2
-
-
... More
M&L Filtration/dehydration cleaning of the existing transformer oil at site of any make of transformer and capacity up to required dielectric strength as per IE rules and refilling in the transformer up to required level complete all as specified and directed. (The dielectric strength shalld not be less than 50 KV at 2.5 mm gap after filtration process) Note : Test result before and after to be recorded.
150
-
-
... More
Taking out of HT cable 95 to185 Sqmm 3 core of any size from ground or poles etc and testing for serviceability and kept aside for reuse including proper rolling, loading unloading, transportation etc complete all as specified and directed. Note:- Earth work for the same shall be measured and paid separately.
100
-
-
... More
M & L for under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts (earthed) grade copper sheet wrapped cross sectional area 11000 Volts 120 Sqmm 3 core including taking down of old unserviceable cable complete all as specified and directed.
300
-
-
... More
M & L for cable end jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 to 185 sqmm including testing after jointing complete all as specified & directed.
1
-
-
... More
M & L for cable end jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 to 185 sqmm including testing after jointing complete all as specified & directed.
1
-
-
... More
M & L for straight through cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 to 185 sqmm including testing after jointing complete all as specified & directed.
1
-
-
... More
M&L for transformer cable boxes or LT panel board cover/ panel doors etc made out of 3.0 mm CRCA sheet duly powder coated complete to make the system safe and secure complete including making hole nut bolts washer cutting and bending in shape, providing hinge of door etc all as per site requirement complete all as specified and directed.
2
-
-
... More
Supply and Install GI Pole of size 80mm dia medium grade of 8.5 mtr The remaining, portion of the exterior shall be painted with one coat of red oxide primer complete with GI base plate and finial taper plug, bolts, nuts & screws as all complete all as specified and directed.
10
-
-
... More
Supply and Install Tubular steel poles shall be swaged type & shall conform to IS 2713 (Parts 1 to 3) 1980. A through hole of 14 mm diameter shall be provided in each pole at a height of 300 mm above the planting depth for earthing arrangements.Finials and base plate shall be of cast iron and conform to the details given in fig. 3 and 4 of the Standard (I.S. 2713 Part 1 to 3-1980).Protection Against Corrosion The poles shall be coated with two coasts of black bituminous paint throughout internally, and externally up to the planting depth. The remaining, portion of the exterior shall be painted with one coat of red oxide primer complete with CI base plate and finial taper plug, bolts, nuts & screws as specified type 410 SP 31,(9.0 Mtr long) all as directed including Dismantling existing PCC poles/ struts, any size for including necessary excavation demolition of concrete pole and removing the old unserviceable rubbish retrieved from dismanteled pole from site appx. 150 mtr from site. Note : Being old poles are of nil value no credit will be deducted against the item.
2
-
-
... More
Supply and Install Tubular steel poles shall be swaged type & shall conform to IS 2713 (Parts 1 to 3) 1980. A through hole of 14 mm diameter shall be provided in each pole at a height of 300 mm above the planting depth for earthing arrangements.Finials and base plate shall be of cast iron and conform to the details given in fig. 3 and 4 of the Standard (I.S. 2713 Part 1 to 3-1980).Protection Against Corrosion The poles shall be coated with two coasts of black bituminous paint throughout internally, and externally up to the planting depth. The remaining, portion of the exterior shall be painted with one coat of red oxide primer complete with CI base plate and finial taper plug, bolts, nuts & screws as specified type 410 SP 55,(11.0 Mtr long) all as directed, including Dismantling existing PCC poles/ struts, any size for including necessary excavation demolition of concrete pole and removing the old unserviceable rubbish retrieved from dismanteled pole from site appx. 150 mtr from site. Note : Being old poles are of nil value no credit will be deducted against the item.
2
-
-
... More
M & L in repair for switch Air break gang operated triple pole out door type 11 KV 50 cycle AC(GOD) suitable for current rating upto 200 Amps mechanically operated mounted on silicon rubber insulators (12 insulators) and frame with operating mechanism from ground level with earth switch and including locking arrangement complete all as directed.
3
-
-
... More
M&L for painting to existing 2 pole structure including pole, cross arm, bracing clamps, GO DO fuse etc with 2 coat of heat resistance aluminium paint above coping complete all as specified and directed.
4
-
-
... More
M &L disconnecting and taking out old unserviceable damaged/burn out cable of any size & make and supplying, laying, jointing and testing LT underground cable, heavy duty cable of size 10 Sqmm 2 Core, 1100 Volts, XLPE insulated and PVC sheathed, armoured, multi-stranded aluminium conductor cable conforming to IS , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly protected in galvanised steel pipe of suitable sizes all bare conductor of cable including cable gland and lugs etc at both ends incl disconnecting and taking out unserviceable damaged cable complete all as specified and directed. Note : Excavation, earth work, cable sand cushioning & cable protection shall be measured separately under relevant items of this schedule.
200
-
-
... More
All as per item here -in- before but 10 Sq mm,4 core
70
-
-
... More
All as per item here -in- before but 16 Sq mm,4 core
100
-
-
... More
All as per item here -in- before but 25 Sq mm, 4 core
300
-
-
... More
All as per item here -in- before but 50 Sq mm, 3.5 core
400
-
-
... More
All as per item here -in- before but 95 Sqmm 3.5Core
300
-
-
... More
All as per item here -in- before but 120 Sqmm 3.5Core
249
-
-
... More
All as per item here -in- before but 185 Sqmm 3.5Core
217
-
-
... More
All as per item here -in- before but 300 Sqmm 3.5Core
201
-
-
... More
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cable, foundation etc and getting out complete all as specified and directed.
371.09
-
-
... More
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in soil complete all as specified and directed by Engr-In-Charge.
325.24
-
-
... More
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified.
45.85
-
-
... More
Supply, laying of Telerex DWC (double Wall corrugated) HDPE polyethiline pipe ISI marked including couplers, bends, cap etc. with smooth internal and profiled external surface for non pressure under ground cable complete all as secified of following size. Make : Gemini/Rex Polyextrusion Ltd or equivalent
-
-
-
... More
Outer dia of 90 mm and inner dia 76 mm
856
-
-
... More
Outer dia of 120 mm and inner dia 103.5 mm
773.6
-
-
... More
Cutting existing road/hardstand of any type by using crow bar chisel uprto a depth of 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
3
-
-
... More
S&F for replacement and repairs complete all as specified & directed for the following items :- MCCBs 63 A, 415V, 16KA, 4 Pole
5
-
-
... More
MCCBs 100 A, 415V, 25KA, 4 Pole
3
-
-
... More
MCCBs 200 A, 415V, 36KA, 4 Pole
2
-
-
... More
MCCBs 250 A, 415V, 36KA, 4 Pole
2
-
-
... More
MCCBs 400 A, 415V, 36KA, 4 Pole
2
-
-
... More
Supply and Install for replacement of Change Over load swicth 63 A complete all as specified & directed by Engr-in-Charge.
8
-
-
... More
All as per item here -in- before but Change Over load swicth 32 A
10
-
-
... More
All as per item here -in- before but Change Over load swicth 100 A
10
-
-
... More
All as per item here -in- before but Change Over load swicth 125 A
2
-
-
... More
Supply and lay in trenches fixed to poles wall laid in floor GI steel tubing medium grade of following bore including fitting bolt, nut & washers etc or wooden rubber bushing at the ends of complete all as specified and directed incl disconnection and taking down existing tubing complete.
-
-
-
... More
80mm bore (dia)
3
-
-
... More
50 mm bore (dia)
3
-
-
... More
Taking down existing connection from LT Panel/Bus Bar Chamber/Feeder Piller/ Electric Poles/ Building carefully (any capacity ,any type) carrying out repair work at site including replacement of unserviceable/ defective screw/nut & bolts/ Washers/Lugs/Spreaders/Hinges of doors/Repair to Locks & handles/ Indication Lamps/meters/Cable glands/Bus Bar (Copper/Aluminium) etc, refixing the fittings in its original position, testing and commissioning, including removal of bushes, creapers and trimming of branches around the LT Panel/Bus Bar Chamber/Feeder Piller/ Electric Poles including takingout fixing site complete all as specified and directed .
Note: (i) If any major repair is required, attending complaints and replacement of any nature in LT Power network at any point and time, the items shall be replaced with respective item of sch 'A' is deemed to be inclusive (ii) Tools, ladder, vehicle required to carry out the work shall be provided by the contractor. (iii) Contractor will ensure the safety of the workers employed at his own risk.(iv) Contractor shall provided Skilled ITI Electrician and Produce the Certificate before the commencment of work. (v) Contractor should ensure to rendering completion of all attended complaints to respective JEs/Engr-in Charge as day to day basis .
5
-
-
... More
Supply and fix, cable jointing kit for straight through heat shrinkable type joint with jointing material and all connected accessories suitable for XLPE armoured aluminium conductor cable 1100 volts grade of size 3.5 core 240 to 300 sqmm including taking down of old existing joint complete all as specified,and as directed
2
-
-
... More
All as per item here in above but cable jointing kit of size 150 to 185 sqmm
2
-
-
... More
All as per item here in above but cable jointing kit of size 70 to 120 sqmm
4
-
-
... More
All as per item here in above but cable jointing kit of size 25 to 50 sqmm
2
-
-
... More
All as per item here in above but cable jointing kit of size 10 to 16 sqmm
2
-
-
... More
M&L for earthing complete with galvanized iron or steel earth plate electrode 60cm x 60cm x 6mm connected to galvanized iron strip 25 X 4 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point /transformer nuetral/body/ Lt panel etc. and testing on completion, complete all as specified & directed by Engr-in-Charge.
12
-
-
... More
Material and labour for fault detection in UG LT/HT cable of any size or type at any depth with fault locator including material T&P required for the same and testing complete all as specified and directed. Note 1- Joint, excavation laying only of cable shall be measured and paid separately. 2. Each fault shall be treated as one job and contractor have to address the said fault immediately.
10
-
-
... More
Supply, install, test and commissioning of transformer,outdoor type,step down 11/0.433 KV (at no load) with HT 3 phase and LT 3 phase 4 wire AC,50 Hz,160KVA, copper wound with off load tap changing arrangement on HT side for a variation of secondary voltage +/- 7.5% in steps of +/- 2.5% including suitable cable entry boxes on LT side and HT bushing on primeyr side complete in all respects with standard aceessories and fitments confirming to IS 2026 as specified and as directed including the following :- (a) Earthing terminal and rating the diagram plate. (c) Air release device. (d) Oil filling inlet pipe with plug. (e) Drain outlet pipe with brass gate valve with dummy plug. (f) Conservator with level gauge. (g) Silica gel with breather. (h) First Oil fill up to the recommended level by the manufacturer with new oil conforming to IS 335. (j) Type of connection Delta/Star. (k) Type cooling : ONAN. (l) Vector Group : DYN 11. (m) Type of connecting arrangement cable termination boxes on LT side. (n) Provision of thermometer with pocket.
1
-
-
... More
M&L for Opening of transformer up to 400 KVA top cover by extraction, removing of serviceable/ unserviceable nuts bolts and washers draining out of transformer oil , lifting HV/ LV coils for inspection etc .
Note : Contractor should carried Pre-inspection of transformer at the Company and obtain necessary photos and certificate of Coil cutting MES from company duly signed by Inspecting officer and Draing out of transformer oil, lifting HV & LV coils for inspection./Engr-in-charge of the Company.
1
-
-
... More
M&L labour transformer winding including taking out and testing for serviceability and rewinding the same with fresh copper wire or strip including insulation paper bobins, Press Board & Insulation, Gasket & washer, Silica Gel Breather, HV & LV Termination, sundry items like Tapes, Sleeves, Bakellite, Nut & Bolts wherever required, Heating, Drying & Meggar Improvement, complete with all existing serviceable parts and new parts as per requirement and keeping the same into the hot air oven till the moisture will remove and insultating resisitance improves to the satisfaction level, refixing the same in original position all as specified and directed by Engr-in-Charge (Old copper scrap will be retained by contractor,under Sch of Credit
102
-
-
... More
Supply and fix LT overhead lines on 9 meter PCC poles/ Steel tubular pole with XLPE insulated AERIAL BUNCHED CABLE (ABC) of size 3-core X 95 sq mm + 1-core X 70 sq mm complete with all mechanical accessories to hang the cable all as specified and directed.
250
-
-
... More
Supply and fix LT overhead lines on 9 meter PCC poles with XLPE insulated AERIAL BUNCHED CABLE (ABC) of size 3-core X 120 sq mm X 1-core X 70 sq mm complete with all mechanical accessories to hang the cable complete all as specified and directed.
250
-
-
... More
Supply and fix in repair aluminium lugs OF SIZE 10-25 Sqmm for LT cables including necessary crimping with crimping tool complete all as specified and directed for th following size and including Taking down
6
-
-
... More
All as per item No 60 here-in before but lugs of size 35 Sqmm
10
-
-
... More
All as per item No 60 here-in before but lugs of size 50 Sqmm
10
-
-
... More
All as per item No 60 here-in before but lugs of size 70-95 Sqmm
16
-
-
... More
All as per item No 60 here-in before but lugs of size 120 -150 Sqmm
10
-
-
... More
All as per item No 60 here-in before but lugs of size 185 Sqmm
6
-
-
... More
All as per item No 60 here-in before but lugs of size 240 Sqmm
3
-
-
... More
All as per item No 60 here-in before but lugs of size 300 Sqmm
3
-
-
... More
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
124
-
-
... More
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
7
-
-
... More
Servicing cleaning & Installation testing of transformer capacity 250 to 400 KVA Dry/Oil type, 11 KV/433 Volts 3 phase from pole/floor/transformer shed with the help of Crane to carry out complete maint of transformer comprising of the following:-
(i) Draining out oil from chamber.
(ii) Opening top cover, disconnecting winding connection from bushings and taking out carefully core assembly complete with winding.
(iii) Checking compactness of core & tightening the same where required.
(iv) Chemical washing of winding to remove dirt,dust & carbon particles
(v) Cleaning of oil tank to remove oil sludge followed by painting of inner surface of tank with zinc chromate base paint
(vi) Refixing of core & winding assembly and making connection with HT/LT bushing .
(vii Replacement of worn out gaskets & nut/bolts.
(Note: Overhauling of transformer should be done on existing installation place on same days)
2
-
-
... More
Servicing cleaning of 11 kv 400 to 630 amp 3 phase 50hz VCBs by cleaning of moving parts and ARC contacts with CR . Checking of tripping mechaism system calibtation of relay.
1
-
-
... More
Servicing cleaning of LT breaker proper checking of fixed and moving contacts archig contacts cheking of mechanical & electrical tripping system.
1
-
-
... More
Supply and fixing of Calibration VCBs
1
-
-
... More
Supply and installation of 11 KV single phase in door resin cast CT of ratio 400/5-5A class 1.0/ 5P10,burden 15VA – 15 VA, and testing on completion, complete all as specified & directed by Engr-in-Charge.
1
-
-
... More
Supply and installation of 11 KV single phase in door resin cast PT of ratio 11 KV/rt3/110 /rt3/110V/rt3,Class 0.5-3, Burden 50 VA – 50 VA and testing on completion, complete all as specified & directed by Engr-in-Charge.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%