Comprehensive Maint And Repair Work Of Certral Ac Plants, Package Type Ac Plant, Split Ac Window Ac And Allied Works Including Connected Misc Items At Irde Under Ge (i) Rnd Dehradun
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_663443_1Bid Award Id
ViewTender No
GE(I)RND/9366/E8/24-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
30 TR capacity AC plant (installed at Chetak Buildling ).
1
-
-
... More
45 TR capacity AC Plant (installed at Large Optics Building IRDE)
2
-
-
... More
65 TR capacity AC Plant (installed at MMG / Optics Building IRDE)
3
-
-
... More
80 TR capacity AC plant (installed at Photonic Buildling & EOL/ TIS Building IRDE).
3
-
-
... More
Dismantling the head from compressor fitted in system, and strip opening of compressor head of twin cylinder for Model AC 27.5 TR of Kirloskar make SMC 8-65 model of ACCEL compressor completely for servicing /overhauling mechanically and electrically, and checking of various components with precision instruments to assess the requirements of repair/replacement, and making inventories for repairs required and re-fixing the serviceable parts in position after proper cleaning, oiling/greasing,etc ,and removing & replacement of defective / unserviceable parts with new parts, as required at site, and reassembling the compressors head ensuring perfectly leak proof after cleaning the oil sump, oil pump connecting rod, piston, liner etc and filling of compressor oil, before charging of refrigerant gas to required pressure and testing at site on full load to the entire satisfaction complete all as specified and directed for following :- ( included notes mentioned in here in after)
Notes: - (i) The replacement of defective / nonfunctional parts, and Refrigerant gas and compressor oil for top up shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing/filling rate for new items are deemed to include under these items. (ii) The refregrent gas to be pumped down before dismantlling the compressure head for avoid the wastage of gas. (iii) The quoted rate shall be deemed to include replacement of small/ minor parts for prroper functioning of compressure .
1
-
-
... More
M&L for cutting and grinding the crank-shaft (for 27.5 TR of Kirloskar make/SMC 8-65 model of ACCEL compressor) of 0.50/0.75 mm around as required to make it equivalent to manufacturer’s standard size and smoothening/ fine finishing,polishing of shaft to match with half section big end bearings, cleaning oil ports for proper lubrication complete all as specified and directed by Engr-in-Charge. Note : (i) The cost of taking out and re-fixing of the shaft / rod in position after necessary repairs is deemed to be included under the rates quoted by the contractor for respective Schedule `A' item.
(ii) The rates for above items are deemed to include transportation to & fro of crank-shaft to workshop for necessary repairs.
2
-
-
... More
Supply only following items / spare parts suitable for Kirloskar make compressors of semi sealed 27.5 TR / 8-65 Accel Make dismantled / fixed under Sch ‘A’ item No.2 here in above complete all as specified and directed
-
-
-
... More
Cylinder liner
2
-
-
... More
Piston Bare
2
-
-
... More
Compression ring set
2
-
-
... More
Piston pin/ gudgen pin
2
-
-
... More
Circlip internal
3
-
-
... More
Connecting rod -05mm
1
-
-
... More
Suction valve 'o' ring
2
-
-
... More
Suction & Discharge valve spring
3
-
-
... More
Discharge valve assembly (R-22)
2
-
-
... More
Crank shaft AC COMPRESSOR 27.5 TR of Make KIRLOSKER/8-65 Accel
1
-
-
... More
Safety plate
1
-
-
... More
Shaft seal assembly
1
-
-
... More
Rewinding of semi sealed compressure 27.5 TR
1
-
-
... More
Filter wire gauge
1
-
-
... More
Suction filter with nut
1
-
-
... More
Oil pump with ring set for compressure 27.5 TR
1
-
-
... More
Set of gasket for compressure 27.5 TR
1
-
-
... More
Main bearing .05 mm.
1
-
-
... More
Oil filter
1
-
-
... More
loading coil
1
-
-
... More
pressure gauge - 30 to 300 PSI
2
-
-
... More
Carrying out leak detection in the system of AC plants including nitrogen pressure testing for 24 hours and repairing the leakage by gas welding / electric welding of refrigerant pipes, replacement of valve gland, gaskets etc. and then creating vacuum for 4 hours before charging refrigerant gas R-22 in the system and testing the complete plant for working pressure for 24 hours complete, all as specified and directed.
Note : R-22 gas shall be measured and paid separately under Schedule ‘A’ Item.
-
-
-
... More
11 TR capacity AC Plant Package Type(installed at Mechanical Lab Technical Area. IRDE)
1
-
-
... More
27.5 /27 TR capacity AC Plant (installed at Micro /C V RAMAN Building IRDE)
2
-
-
... More
30 TR capacity AC plant (installed at Chetak Buildling ).
1
-
-
... More
45 TR capacity AC Plant (installed at Large Optics Building IRDE)
1
-
-
... More
65 TR capacity AC Plant (installed at MMG / Optics Building IRDE)
3
-
-
... More
80 TR capacity AC plant (installed at Photonic Buildling & EOL/ TIS Building IRDE).
3
-
-
... More
Supply, fixing, connecting and testing in replacement of UNSV strip heater fins type, 3.0 KW, 230 volts, single phase, AC supply in any position complete, all as specified and directed.
25
-
-
... More
Supply of refrigerant gas monochloro difluoro methane (CHCLF2) R- 22 conforming to IS-5160 of 1983 , duly filled in factory sealed cylinder standard capacity for filling under Sch ‘A’ item No 5. and here in above complete, all as specified and directed.
110
-
-
... More
Supply only R-134A/410 refrigrant gas with testingn under Sch ‘A’ item 2 here in above complete, all as specified and directed.
175
-
-
... More
Heater Element size and capacity as per existing Watre heater Generator 100/54 KW complete, all as specified and directed.
1
-
-
... More
Supply of lubricating oil anti freezing for refrigeration in factory sealed container of standard capacity for filling under Sch ‘A’ items No 3 complete,all as specified and directed. Make: Servo froze -68-10c of IOC.
15
-
-
... More
Supply fixing and testing in replacement of UNSV pre filter with GI sheet frame of size 610mm x 610mm x 50mm deep suitable for Air handling units of air conditioning plants including efficiency 90% , down to 10-20microns, Initial Pressure drop- 2.5 mm WG, filter media shall be Synthetic Non Woven with Both Side HDPE Mesh, and testing complete complete, all as specified and directed.
15
-
-
... More
Supply fixing and testing in replacement of UNSV condencer safety valve of size 3/4"& ½”, for pressure 300 PSI with and Including 3/4"& ½”, mild steel socket duly welded on condenser ensuring perfectly leak proof joint with pressure testing complete all as specified and directed.
2
-
-
... More
Supply fixing and testing in replacement of UNSV thermostatic expansion valve (R-22) suitable for 80 TR capacity of central AC plant complete, all as specified and directed.
1
-
-
... More
Supply fixing and testing in replacement of UNSV water pressure gauge 100 mm dia of range 0 to 100 PSI suitable for central AC plant complete all as specified & directed.
5
-
-
... More
Supply fixing and testing in replacement of UNSV Gas pressure gauge 100 mm dia of range 0 to 300 PSI suitable for central AC plant complete all as specified & directed.
5
-
-
... More
Supply fixing and testing in replacement of UNSV Water flow switch for condenser and chiller suitable as per existing AC Plant Make :Carrier (Screw Chiller Unit) complete, all as specified and directed
10
-
-
... More
Supply fixing and testing in replacement of UNSV sensor for low pressure/High Pressure/Oil Pressure switch suitable for as per existing suitable for AC Plant Make :Carrier (Screw Chiller Unit) complete, all as specified and directed
1
-
-
... More
Supply fixing and testing in replacement of UNSV Loading/ unloading coil suitable for as per existing AC Plant. Make :Carrier (Screw Chiller Unit) complete, all as specified and directed
1
-
-
... More
Supply fixing and testing in replacement of UNSV PVC Fills of FPR cooling tower size 600mmx300mmx 150 mm complete, all as specified and directed
5
-
-
... More
Disconnecting and removing old existing non functional electric motor, of any description and in any position from existing platform for compressor/blowers/pumps/ cooling towers and dismantling and strip opening of the motor, for cleaning oiling/greasing and fixing of serviceable parts in position and removing the old existing burnt windings, cleaning the slots & rewinding of the electric motor with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc for powering compressor /blowers /pumps / cooling towers and transportation to site & refixing on existing platform ,connecting with exising connections & testing on full load complete all as specified and directed for following capacity :- .
-
-
-
... More
5.0 HP capacity, Three phase 50 Hz AC supply
1
-
-
... More
7.5 HP capacity, Three phase 50 Hz AC supply
1
-
-
... More
10 HP capacity, Three phase 50 Hz AC supply
1
-
-
... More
15 HP capacity, Three phase 50 Hz AC supply
1
-
-
... More
Disconnecting and removing old existing non functional electric motor, of any description and in any position from existing platform for pumps and dismantling and strip opening of the motor, for cleaning oiling/greasing, Replaceing UNSV suitable size of bearing and fixing of bearing, imppler serviceable parts in position pumps and transportation to site & refixing on existing platform ,connecting with exising connections & testing on full load complete all as specified and directed for following capacity :-
-
-
-
... More
5.0 HP capacity, Three phase 50 Hz AC supply
1
-
-
... More
7.5 HP capacity, Three phase 50 Hz AC supply
1
-
-
... More
10 HP capacity, Three phase 50 Hz AC supply
1
-
-
... More
15 HP capacity, Three phase 50 Hz AC supply
1
-
-
... More
Supply fixing,connecting and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 16 Amps complete all as specified and directed.
Make L&T or equievelent model of specified and directed.
1
-
-
... More
Supply fixing and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 25 Amps complete all as specified and directed .
Make L&T or equievelent model of specified and directed.
1
-
-
... More
Supply fixing and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 32 Amps. Complete all as specified and directed . Cat part No SS90935- Type ML-10 of make L&T or equievelent model of specified and directed. ,
1
-
-
... More
Supply fixing and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 50 Amps. Complete all as specified and directed .
Make L&T or equievelent model of specified and directed.
1
-
-
... More
Supply fixing and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 70 Amps. Complete all as specified and directed .Make L&T or equievelent model of specified & directed
1
-
-
... More
Supply fixing and testing in replacement of UNSV bimetal overload relays directly operated & directly mounted on ML type Power contactor for relay range of 06 to 18 Amps complete all as specified and directed. Make L&T or equievelent model of specified and directed. .
2
-
-
... More
Supply fixing and testing in replacement of UNSV bimetal overload relays directly operated & directly mounted on ML type Power contactor for relay range of 19 to 30 Amps complete all as specified and directed. Make L&T or equievelent model of specified and directed.
2
-
-
... More
Supply fixing and testing in replacement of UNSV bimetal overload relays directly operated & directly mounted on ML type Power contactor for relay range of 32 to 45 Amps complete all as specified and directed. Make L&T or equievelent model of specified and directed.
1
-
-
... More
Supply fixing and testing in replacement of UNSV digital type of size 96mm x 96mm, AC Volt meter 0- 500 Volts including wiring with 1.5 Sqmm PVC insulated stranded copper conductor cable complete all as specified and directed.
2
-
-
... More
Supply fixing and testing in replacement of UNSV digital type of size 96mm x 96mm, AC Amp meter 0- 200 Amps with including 3 Nos C.T of Ratio 200/5 of class-1.0 including wiring with 1.5 Sqmm PVC insulated stranded copper conductor cable complete all as specified and directed.
2
-
-
... More
Supply fixing and testing in replacement of UNSV insulated connectors 4 pole 100 amps rating including testing complete, all as specified and directed
1
-
-
... More
Supply fixing and testing in replacement of UNSV insulated connectors 4 pole 63 amps rating including testing complete, all as specified and directed
2
-
-
... More
Supply fixing and testing in replacement of UNSV Electronic timers 415 Volts, 50 Hz, AC supply, with delay period of 9-30-Seconds complete all as specified and directed make L&T or equievelent model of specified make as approved by the GE
1
-
-
... More
Supply fixing and testing in replacement of UNSV push button ON/OFF complete in the existing panel Complete connecting electrically all as specified and directed
5
-
-
... More
Supply fixing and testing in replacement of UNSV indicator light red/yellow /green complete in the existing panel Complete connecting electrically all as specified and directed
6
-
-
... More
Supply, fixing, connecting and testing in replacement of UNSV thermostat heating/cooling of any description complete,all as specified and directed.
2
-
-
... More
Supply, fixing, connecting and testing in replacement of UNSV MCCB Triple pole, 250 Amps 415 volts, 50 Hz having breaking capacity 35/36 KA , with adjustable thermal and fixed magnetic setting fixed in existing panel Complete all as specified and directed. Make : L&T /INDO ASIAN/Havells
1
-
-
... More
Supply, fixing, connecting and testing in replacement of UNSV MCCB Triple pole, 200 Amps 415 volts, 50 Hz having breaking capacity 36 KA , with adjustable thermal and fixed magnetic setting fixed in existing panel Complete, all as specified and directed. Make : L&T /INDO ASIAN/Havells
1
-
-
... More
Supply, fixing, connecting and testing in replacement of UNSV MCCB Triple pole, 100 Amps 415 volts, 50 Hz having breaking capacity 25 KA , with adjustable thermal and fixed magnetic setting fixed in existing panel Complete, all as specified and directed. Make : L&T /INDO ASIAN/Havells
1
-
-
... More
Supply, fixing, connecting and testing in replacement of UNSV Honeywell CN7510A2001 valve actuator suitable for existing air cooled air conditioner plant 45 TR complete, all as specified and directed.
(Installed at Large Optics Building)
1
-
-
... More
Supply & fixing in repair of 80 TR AC Plant FRP Cooling tower etc complete all as specified and directed. (Installed at Photonics Building )
2
-
-
... More
Supply & fixing 80 TR AC Plant PLC Card etc complete all as specified and directed. (Installed at Photonics Building )
1
-
-
... More
Installation only split type AC including indoor/outdoor unit of capacity 1.5 Ton/2 Ton after carried out the repair under item at new location as directed including providing necessary chiseling/ cutting for fix the indoor/outdoor unit by means of suitable size of nut, bolt, angle iron structure, masonry work and making good the disturbed surface with PCC, plastering,white wash works,testing & checking complete,all as directed & specified by Engineer-in-Charge. (Note :- The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, blower motor and nut bolt angle iron structure) under relevant items shall be included in this item) complete all as specified and directed
3
-
-
... More
Supply & Fixing in replacement of unserviceable Oudoor unit body complete with compressor unit suitable for existing Split type AC of 1.5 TR capacity complete all as specified and directed
3
-
-
... More
Supply & Fixing in replacement of unserviceable indoor unit body complete suitable for existing Split type AC of 1.5 TR capacity complete all as specified and directed
3
-
-