Military Engineer Services Tender

View complete overview of Uttarakhand MES Tender

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Jul 2024
Closing Date4 Sep 2024
Tender Amount₹ 35,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply only cable twin core PVC insulated and unsheathed solid aluminium conductor of size 2.50 Sqmm complete all as specified and directed.

300

-

-

... More
Supply only of Integral LED street light driver, enclosed with glass cover frame suitable for existing make/models of LED street light/flood lights of capacity 25/30 W complete all as specified and directed.

30

-

-

... More
ditto all as sl item No 4.00 above but for capacity 40/45/48/50 W complete all as specified and directed.

160

-

-

... More
ditto all as sl item No 4.00 above but for capacity 60/65/70/72/80/90 W complete all as specified and directed.

20

-

-

... More
Supply only of Integral LED street light module with complete PCB and LED bulb suitable for 25/30 W LED street light for existing make and model complete all as specified and directed.

15

-

-

... More
ditto all as sl item No 7.00 above but suitable for capacity 40/45/48/50 W complete all as specified and directed.

80

-

-

... More
ditto all as sl item No 7.00 above but suitable for capacity 60/65/70/72/80/90 W complete all as specified and directed.

10

-

-

... More
Supply only of surge protector device for protection upto 10 KV surge voltage suitable for existing make/models of LED street light/flood lights of capacity 25Watt to 100 Watt complete all as specified and directed.

40

-

-

... More
M&L for repair of Street light timer any type including setting/resetting of timing of ON/OFF at dusk & dawn for Street light connected to that Timer including checking of connection of contactor & timer circuits complete all as specified & directed by Engr in charge.

12

-

-

... More
S&F timer digital type suitable for street light timer including dismantling existing un serviceable from the timer assembly and making reconnection connection complete all as specified & directed.

6

-

-

... More
S&F in repair of nature timer switch with sensor as per existing capacity and ranges complete all as specified & directed including dismantling existing un serviceable from the timer assembly and making reconnection connection all as specified and directed by Engr-in-charge.

8

-

-

... More
S&F in repair contactor rating 63 Amp (MNX 63) of existing make/model suitable for street light timer including dismantling existing un serviceable from the timer assembly and making reconnection connection all as specified and directed.

2

-

-

... More
ditto all as sl item No 14.00 above but for capacity 70 amp(MNX 70) complete all as specified & directed.

2

-

-

... More
ditto all as sl item No 14.00 above but for capacity 40 amp(MNX 40) complete all as specified & directed.

4

-

-

... More
ditto all as sl item No 14.00 above but for capacity 32 amp(MNX 32) complete all as specified & directed.

4

-

-

... More
S&f in repairs Isolator 4 pole 63 Amps,415 Volts all as specified and directed.

4

-

-

... More
S&f in repairs Isolator 2 pole 40 Amps,220 Volts all as specified and directed.

2

-

-

... More
S&f in repairs powder coated pressure die cast aluminium compact LED street light fitting heat resistance with lens on LED diode suitable for 30Watt with IP 66 protection complete all as specified & directed.

20

-

-

... More
ditto all as sl item No 20.00 above but for capacity 45/50 Watt with IP 66 protection complete all as specified & directed.

80

-

-

... More
ditto all as sl item No 20.00 above but for capacity 60 Watt with IP 66 protection complete all as specified & directed.

10

-

-

... More
S & F in repairs powder coated pressure die cast aluminium compact LED flood light heat resistance toughened glass suitable for 50 Watt with IP 66 protection complete all as specified & directed.

10

-

-

... More
ditto all as sl item No 23.00 above but for capacity 100 Watt with IP 66 protection complete all as specified & directed.

4

-

-

... More
S&F in replacement post top energy saving environment friendly long life aesthetically designed with symmetrical light distribution LED Post Top lantern /gate light of capacity 20/25/30 watt with spun aluminium landscape luminaire with high power LEDs as light source complete all as specified & directed.

20

-

-

... More
ditto all as sl item No 25.00 above but for capacity 40/45 Watt complete all as specified & directed.

10

-

-

... More
S&F in replacement LED Bollard light fittings (garden lights) of size not less than 600 mm height energy saving eco friendly robust body of capacity 8 watt with PCC works and fixing arrangement complete all as directed.

24

-

-

... More
S&F in replacement Globe light with bulb holder & LED bulb fitting complete of cap 9-10 watt with fixing arrangement complete all as directed.

20

-

-

... More
S&f in repairs LED Highbay Fitting 100 Watt with PDC aluminium housing with aim & adjustable bracket, Mat finished reflector for glare elimination, SMD LED with secondary lens & Integral SMD LED with pressure die cast aluminium housing, anodised aluminium reflector, complete with accessories IP-65 protection with necessary electrical connections alongwith iron chain suitable for bearing the load of fitting upto 1 mtr for extension upto ceiling of any height complete all as specified & directed.

2

-

-

... More
Supply and fix in repairs loop-in loop-out box of size 20X20x15 cm made of 1.6mm thick PVC sheet weather proof, dust and vermin proof with hinged door of locking arrangements and slanting cover on top with provision of aluminium busbar of size 25 x 2mm - 2 No fixed on insulator complete fixed on pole with and including suitable size MS flat iron clamps, nuts, bolts and washers, etc complete all as specified & directed.

20

-

-

... More
S&f in repairs street light bracket made out of 40 mm dia GI pipe light grade of length upto 1.5 mtr bent to shape required with and including 2 Nos, 50 x 6 mm MS flat iron clamps with nuts, bolts, washer etc and applying one coat of aluminium paint to clamps including dismantling of old brackets complete all as specified and directed.

20

-

-

... More
S&f in repairs commissioning and testing of Nature timer switch control Street Lights complete with MCB, Power and Panel duly complete with wiring Model : SWADEEP-02EC 12KW 3P, or equivalent three phase ,max load 12KW complete all as specified and directed. Note :- CA No & date of installations shall be painted/marked on all timer switch provided by the contractor.

1

-

-

... More
S&f in repairs commissioning and testing of Nature timer switch control Street Lights complete with MCB, Power and Panel duly complete with wiring Model : SWADEEP-02EC 8KW 1P, or equivalent single phase ,max load 8KW complete all as specified and directed. Note :- CA No & date of installations shall be painted/marked on all timer switch provided by the contractor.

1

-

-

... More
S&f in repairs commissioning and testing of Digital Astronomical timer street light control panel of three phase Max load 12 KW complete with contractor rating 65/TP, MCB rating 63 Amp TPN complete all as specified and directed. Note :- CA No & date of installations shall be painted/marked on all timer switch provided by the contractor.

3

-

-

... More
S&F in repairs commissioning and testing of Digital Astronomical timer street light control panel of single phase ,max load 8 KW complete with contractor rating 32/TP, MCB rating 40 Amp SPN complete all as specified and directed. Note :- CA No & date of installations shall be painted/marked on all timer switch provided by the contractor

1

-

-

... More
S&F in replacement of 1100 Volts grade heavy duty cable one twin core, flat or circular 6 Sqmm PVC insulated aluminium solid conductor served with inner sheathing of PVC tapes and overall PVC sheathed in service connection from pole to Main Switch complete all as specified and directed.

500

-

-

... More
ditto all as sl item No 36.00 above but of size 10 Sqmm twin core complete all as specified and directed.

800

-

-

... More
ditto all as sl item No 36.00 above but of size 16 Sqmm twin core complete all as specified and directed.

100

-

-

... More
Supply and fixing in replacement of Cable route markers made of galvanised iron with embossing of HT Cable or LT Cable, supporting MS angle of 75 cm long, for HT/LT cable route marking duly embedded in and incl PCC (1:3:6) foundation up to 30 cm incl excavation and earth work.

20

-

-

... More
Lopping / pruning of tree branches upto the extend to obtain clearance all around the LT over head lines / HT over head lines conductor upto 3 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as specified and directed. Note :- (a). The trees branches etc will be left as it is and will not be carried away by the contractor / DEL as the wood belongs to CEO / DEO and they will be responsible to lift the wood. (b). pruning of all tree branches in one tree shall be measured as one Job. c). Contractor will employ sufficient labour to complete the job with in time as directed. (d). Contractor will be responsible for any type of mis-happening / accident while pruning the trees. (e). Contractor supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply . However full assistance will be provided by MES staff. (f). The contractor will provide proper tools and safety devices to his staff for pruning of trees.

75

-

-

... More
Clearing away all grass vegetation ,saplings, shrubs, brush wood undergrowth roots and trees not exceeding 30 CM girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance soft/loose soil and getting out including spreading of anti vegetation chemical on complete Area complete all as specified & directed.

980

-

-

... More
S&f in repairs micro prismatic reflective sheet, min 2.5 cm wide, with adhesive base for direct fixing on HT/LT steel tubular/PCC pole without nail or any other fixing material at suitable height, in Red/White/Yellow colour complete all as directed.

20

-

-

... More
Supply & fixing in replacement shackle type porcelain vitreous white, brown or green insulator including one galvanised mild steel straps, washers and nut 75 mm height, 90 mm dia for 1100 volts grade, including removal of existing insulators complete all as specified & directed.

6

-

-

... More
Supply & fixing in replacement pin type porcelain vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height, 65 mm dia for 1100 volts grade, including removal of existing insulators complete all as specified & directed.

6

-

-

... More
Taking down of old aluminium conductor of any description /size from LT Poles including cross arms, bracing and other steel accessories complete all as specified & directed.

1.5

-

-

... More
Refixing of ACSR conductor, removed under Item No 45 on existing or new LT poles including binding with 02 mm dia aluminium binding wire & stretching of conductor upto proper sag limit complete all as specified & directed.

1.25

-

-

... More
S&f ACSR conductor of any size including binding on existing LT poles or new poles with 02 mm dia aluminium binding wire complete all as specified & directed.

0.25

-

-

... More
S&f in repairs cross arms (any type) supports, brackets, stiffners etc made out of MS channel, angle iron , flat iron of any size including drilling of holes, making clamps, eye hooks, nuts, bolts and washers etc, welding if required including painting with two coats of aluminium paint over a coat of red oxide paint as well as dismantling of existing complete all as specified & directed.

0.25

-

-

... More
Supplying, drawing and fixing in replacement of continuous GI earth wire/guard/cradles of 4mm dia including GI binding wire 1.63 mm and GI holding hook on HT/LT poles incl taking down old rusted GI wire complete all as specified & directed.

0.1

-

-

... More
Cleaning and preparation of old painted surface of LT/street light pole complete and painting with one coat of aluminium paint including channels/ brackets, street light brackets, cross arms and making red & white strips with synthetic enameled paint of 30 cm height, each alternative strip upto 1.5 mtr height and writing pole numbers with black synthetic enameled paint after making circular base with yellow synthetic enameled paint and applying white wash on existing PCC coping complete all as specified.

400

-

-

... More
Supply and erection (in truly vertical position) in replacement of LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP 31 09 mtrs long Class -10 including painting of poles with two coats of synthetic enamel paint in red and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed by Engineer in charge. Note : PCC, Earth work and MS work as cross arms clamps etc will be measured and paid separately.

8

-

-

... More
S&F stay assembly (in replacement) consisting of galvanised stay wire 7/10 SWG stay bow of 14 mm dia, stay rod 16 mm dia 180 cm long with loop insulators stay plate 230 x 230 mm x 6 mm with PCC foundation 1:3:6 type C2 complete with stay clamps, bolts and nuts all as specified and directed including the following :-. (a) Excavation and earth work for stay foundation in soft/loose soil,disposal of surplus soil to a distance n exc 50 metres & depositing where directed at a level n.exc 1.5 mtr from the starting point as directed. (b) PCC 1:3:6, type C-2 ( using 40 mm graded stone aggregate ) as in embedding blocks all as specified.

1

-

-

... More
M&L taking out old earthing and providing eearthing complete with galvanised or steel earth plate electrode of size 60cm x60cmx6mm thick buried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to strip 32x 6 mm size with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to earthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR(Pt-I)1991 complete all as specified & directed.

6

-

-

... More
S&f in repairs galvanized iron strip of size 32x6 mm as earth continuity conductor provided in between earth test point terminal and upto the equipment incl nuts, bolts and washers complete all as specified and directed.

12

-

-

... More
Supply and fixing in replacement of danger notice plate of 1.6mm thick, MS sheet, vitreous enameled white, with letters, figuresand conventional skull and bones in signal red colour and fixed with MS clamps made out of flat iron 25X3 mm, nuts-bolts, of approved size for LT 20 x 15 cm complete all as specified & directed.

20

-

-

... More
S&f in repairs PVC LT OH line spacer for 4 wires complete all as specified and directed.

8

-

-

... More
S&f in repairs PVC LT OH line spacer for 2 wires complete all as specified and directed.

8

-

-

... More
Dismantling of existing change over switch including disconnection and connection of LT cable complete and supply fixing of offload change over switch of capacity 100 Amp TPN with enclosure box including handle and other accessories complete all as specified & directed.

1

-

-

... More
Dismantling of existing change over switch including disconnection and connection of LT cable complete and supply fixing of offload change over switch of capacity 200 Amp TPN with enclosure box including handle and other accessories complete all as specified & directed.

1

-

-

... More
S&f in repairs heat shrink LT end joints of size 70 sqmm to 95 sqmm complete all as specified & directed.

2

-

-

... More
S&f in repairs heat shrink LT end joints of size 120 sqmm to 150 sqmm complete all as specified & directed.

1

-

-

... More
S&f in repairs testing and commissioning of epoxy type straight through jointing kit suitable for LT cable of size 10 Sqmm to 70 Sqmm, 3.5 to 4 core, XLPE insulated, PVC sheathed armoured 1100 volts grade complete all as specified & directed.

1

-

-

... More
ditto all as sl item No 62.00 above but 95 to 120 Sqmm.

2

-

-

... More
ditto all as sl item No 62.00 above but 150 to 185 Sqmm.

1

-

-

... More
S& F in replacement of Aluminium Lugs / connectors of size 16 sqmm complete all as specified & directed.

16

-

-

... More
ditto all as sl item No 65.00 above but of size 25 sqmm

16

-

-

... More
ditto all as sl item No 65.00 above but of size 35 sqmm

16

-

-

... More
ditto all as sl item No 65.00 above but of size 50 sqmm

16

-

-

... More
ditto all as sl item No 65.00 above but of size 70 sqmm

16

-

-

... More
ditto all as sl item No 65.00 above but of size 95 sqmm

16

-

-

... More
ditto all as sl item No 65.00 above but of size 120 sqmm

12

-

-

... More
ditto all as sl item No 65.00 above but of size 150 sqmm

12

-

-

... More
ditto all as sl item No 65.00 above but of size 185 sqmm

12

-

-

... More
ditto all as sl item No 65.00 above but of size 240 sqmm

6

-

-

... More
ditto all as sl item No 65.00 above but of size 300/400 sqmm

6

-

-

... More
S&F in repairs LT PVC tape roll 3/4 inch size ISI marked on Panels/Transformers LT side complete all as specified & directed.

100

-

-

... More
Excavation in trenches in any type of soil n.exc. 1.5 mtr wide and n.exc 1.5 mtr in depth for LT cables and LT Steel Tubular Poles complete all as specified & directed.

355.65

-

-

... More
Returning, filling in, any type of soil and spreading in layers n. exc 25cm thick each layer including watering & well ramming complete all as specified & directed.

215.45

-

-

... More
Removal of surplus soil to a distance n.exc 50 mtr & depositing where directed at a level n. exc. 1.5mtr above the starting point complete all as specified & directed.

140.2

-

-

... More
M & L for brick protection to cable using old size sub class 'B' bricks, laid flat, dry butt jointed, laid lengthwise perpendicular to the axis of cable all as specified & directed.

9.2

-

-

... More
M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of cable in trenches complete all as specified & directed.

103.65

-

-

... More
Supply and laying in replacement XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,1100 volts grade ,corss sectional area 10 sqmm 2 core complete all as specified and directed.

900

-

-

... More
ditto all as sl item No 82.00 above but 16 Sqmm 4 core

800

-

-

... More
ditto all as sl item No 82.00 above but 25 Sqmm 4 core

300

-

-

... More
ditto all as sl item No 82.00 above but 35 Sqmm 3½ core

300

-

-

... More
ditto all as sl item No 82.00 above but 50 Sqmm 3½ core

300

-

-

... More
ditto all as sl item No 82.00 above but 70 Sqmm 3½ core

100

-

-

... More
ditto all as sl item No 82.00 above but 95 Sqmm 3½ core

100

-

-

... More
ditto all as sl item No 82.00 above but 120 Sqmm 3½ core.

50

-

-

... More
ditto all as sl item No 82.00 above but 150 Sqmm 3½ core.

50

-

-

... More
ditto all as sl item No 82.00 above but 185 Sqmm 3½ core.

50

-

-

... More
ditto all as sl item No 82.00 above but 240 Sqmm 3½ core.

50

-

-

... More
ditto all as sl item No 82.00 above but 300 Sqmm 3½ core.

50

-

-

... More
S & F in replacement GI pipe light grade 80mm bore for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallahetc complete all as specified & directed.

12

-

-

... More
ditto all as sl item No 94.00 above but 50mm bore.

18

-

-

... More
ditto all as sl item No 94.00 above but 40mm bore.

36

-

-

... More
Cutting of floor/wall/road/footpath for removal of LT U/G cable of any size/description and making good the same as per existing specification after relaying the same or new cable and all as specified & directed.

18

-

-

... More
Material and labour for PCC 1:3:6 type C-2,using stone aggregate 40mm graded as in foundation of stays and coping of poles including necessary form work where required and fair finish to the exposed surfaces including demolition of existing damaged PCC all as specified & directed.

12.5

-

-

... More
Material and labour for PCC 1:4:8 type D-2, using stone aggregate 40mm graded as in foundation for electric poles and making of cable duct including necessary form work where required and fair finish to the exposed surfaces all as specified & directed.

8.2

-

-

... More
M&L for in replacement of bus bar chamber, fixed on wall, 4 ways, 200 Amps ,415 V powder coated, water & vermin proof , IP-66 protection duly provided with front openable door incl provision of TPN copper bus bar heat shrinkable colored PVC sleeve coated for phase and neutral complete all as specified and directed.

2

-

-

... More
ditto all as sl item No 100.00 above but with 100 Amp TPN Copper Bus Bar 415V

1

-

-

... More
M&L for in replacement of bus bar chamber, fixed on wall, 4 ways, 200 Amps ,415 V powder coated, water & vermin proof , IP-66 protection duly provided with front openable door incl provision of TPN Aluminium bus bar heat shrinkable colored PVC sleeve coated for phase and neutral complete all as specified and directed.

8

-

-

... More
S&f in repair MS busbar chamber of nominal dimension 900 mm x 600 mm x 300 mm duly provided with aluminimum busbar of size 50 mm x 6mm fixed on porcelain insulators TPN type out door weather/vermin proof with both way opening duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA steel sheet encloser with one No incomer MCCB 250 Amp 36 KA complete all as specifiedand directed incl making connection /thimbles etc complete all as specified & directed.

1

-

-

... More
ditto all as sl item No 103.00 above but with with one No incomer MCCB 100 Amp 25 KA

1

-

-

... More
ditto all as sl item No 103.00 above but of size 600 mm x 600 mm x 300 mm and without MCCB

2

-

-

... More
S & F in replacement MCCB 415 Volts 4 pole 400 Amps 50 Hz 50 KA of existing make model and type alonwith spreader terminal with adjustable thermal setting including lugs/thimbles of suitable size in existing panels complete all as specified and directed. Note : Necessary addition /alterationrequired to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.

1

-

-

... More
ditto all as sl item No 106.00 above but of MCCB 350 Amps 4 pole 50 Hz 415 V with rupturing capacity 36 KA

1

-

-

... More
ditto all as sl item No 106.00 above but of MCCB 250 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA

4

-

-

... More
ditto all as sl item No 106.00 above but of MCCB 200 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA

4

-

-

... More
ditto all as sl item No 106.00 above but of MCCB 160 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA

2

-

-

... More
ditto all as sl item No 106.00 above but of MCCB 125 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA

1

-

-

... More
ditto all as sl item No 106.00 above but of MCCB 100 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA

4

-

-

... More
ditto all as sl item No 106.00 above but of MCCB 63 Amps TPN 50 Hz 415 V with rupturing capacity 16 KA

4

-

-

... More
Note : Tenderers may note that amount of credit Rs 1,58,209.50 will be deducted from the total amount arrived, at the time of Acceptance of contract.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.