Military Engineer Services Tender
View complete overview of Uttarakhand MES Tender
Military Engineer Services - MES Tender
Manpower Supply
Eprocure
Opening Date21 Feb 2025
Closing Date14 Mar 2025
Tender Amount₹ 9,80,000
Costs
EMD
₹ 19,600Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_698833_1Tender No
8972/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR/REPLACEMENT OF GI PIPE LINES, STARTER PANEL, PUMP MOTER, CLEANING OF WATER STORAGE TANK AND ALLIED WORKS UNDER AGE(I) LANSDOWNE
BOQ Items
... More
S & F GI tubing, "Heavy duty" (ISI Marked) with screwed joints or welded joints all as per site requirement incl all fittings heavy duty complete laid in trenches / on walls / on ceiling / roof etc incl necessary suitable size of MS clamps / saddling on walls / ceiling etc complete all as specified and directed at water supply distribution/ pumping system Lansdowne of following bore of GI pipes :- Make:- Jindal Hisar / TATA / Prakash Surya
-
-
-
... More
(a) GI Pipe 150 mm dia
36
-
-
... More
(b) GI Pipe 100 mm dia
36
-
-
... More
S & F in replacement GI fitting Bends, Socket , Union, Flange, Nipple etc (Heavy duty) of size 80 mm to 150 mm dia complete all as specified and directed.
Note :- Site of fixing may be in any pumping installation/distribution system at Lansdowne.
4
-
-
... More
Disconnecting and taking down the existing unserviceable sluice valve 150 mm dia installed in position and removed from site and Supply, Fixing, testing and connecting cast iron sluice valve heavy duty double flanged, 150 mm dia PN 1.6 confirming to IS 14846: 2000 ISI marked with Stainless steel spindle and two nos of MS flange of 16mm thick, 8 holes with nuts and bolts packing materials complete including cutting the existing watermain for fixing cast iron sluice valve and jointing welding complete required at site of water supply installations/distribution system complete all as specified and directed. Make:- Kirloskar/L&T/Bir/ Zoloto/Leader
1
-
-
... More
All as per Item No. 08 above but 100 mm dia complete all as specified and directed.
1
-
-
... More
All as per Item No. 08 above but 80 mm dia complete all as specified and directed.
1
-
-
... More
Disconnecting and taking down the existing unserviceable non return valves of cast iron and supply installing and testing of heavy duty cast iron non return valve PN 1.6 confirming IS 5312-1 (2004) ISI marked along with two Nos of heavy duty flange 16 mm thick, 8 hole suitable for 100 mm dia with all fixing accessories such as suitable size nut and bolts of 16 Nos, packing material of leather buffalo including cutting the existing water main of 100 mm dia for fixing the non return valve, welding jointing complete as per site requirement at water supply installations/distribution system complete all as specified and directed. Make:- Kirloskar/L&T/Bir/ Zoloto/Leader
1
-
-
... More
All as per Item No 11 above but 80 mm dia As per site requirement at water supply installations complete all as specified and directed.
1
-
-
... More
Disconnecting and taking down the unserviceable gun metal gate valve 50 mm dia from installed position and removed from site and Supply, fixing and connecting Gun metal gate valves of size 50mm ISI marked confirmming to IS 778-1984 with iron wheel head, screwed both ends for GI pipe complete all as specified and directed.
Make:- Kirloskar/L&T/Bir/ Zoloto/Leader
2
-
-
... More
All as per Ser No. 13 above but 40 mm dia complete all as specified and directed .
1
-
-
... More
All as per Ser No. 13 above but 25 mm dia complete all as specified and directed.
2
-
-
... More
All as per Ser No. 13 above but 20 mm dia complete all as specified and directed.
2
-
-
... More
All as per Ser No. 13 above but 15 mm dia complete all as specified and directed.
2
-
-
... More
M&L Construction of brick masonry valve chamber (as per standard drawing) of internal size 900x900x900mm with sub class 'B' bricks in cement mortar 1:6 with 2mm thick MS sheet cover and angle iron frame made out of 40x40x6mm angle with locking arrangement duly painted with two coat of bitumen paint over a coat of red oxide primer incl necessary earth work and excavating in soft loose soil returning filling in removal of surplus soil complete incl 100 mm thick PCC 1:4:8 type B-2 (using 40 mm graded stone aggregate) in base concrete and 50 mm thick coping PCC 1:2:4 type B-0 (using 12.50 mm graded stone aggregate) over brick wall top incl. two coats of snowcem rendering plastering work complete all as specified and directed.
4
-
-
... More
Supply and Fixing in repair valve pit chamber top cover of size 900x900 mm made with 2mm thick MS sheet with supporting MS angle iron frame made out of 40x40x6mm and painting with two coat of bitumen paint over a coat of red oxid primer and locking arrangment complete all as specified and directed.
4
-
-
... More
S&F in repair GI elbows/bend/unions/sockets/ tees/nipple with welding joint of 150mm water mains both ends for making leak proof between IInd lift to Stn HQ/SMT tank and any site of water supply installation all as specified and directed. Note:- The cost of Fittings such as elbows/bend/unions/sockets/ tees/nipple etc shall be included in the unit rate quoted by the contractor.
1
-
-
... More
S&F in repair GI elbows/bend/unions/sockets/ tees/nipple with welding joint of 100mm/80mm water mains both ends for making leak proof from Zero to IInd lift and or as per site requirement of water supply installation all as specified and directed.
Make:- Kirloskar/L&T/Bir/ Zoloto/Leader
Note:- The cost of Fittings such as elbows/bend/unions/sockets/ tees/nipple etc shall be included in the unit rate quoted by the contractor.
5
-
-
... More
M & L for angle iron work for support of water pipeline by welding at scattered location complete all as specified and directed.
10
-
-
... More
M&L for walling of square rubble uncoursed well bonded, bedded and solidity hearted built in cement motor 1:6 for support for pipe line complete all as specified and directed. Note: Site of work is hilly terrain which is not approachable by road.
1
-
-
... More
Supply and fixing U-PVC pipe of size 75 mm bore SCH-40 including all pipe line fittings like elbow, socket plug hose clip adaptors cutting through walls floors and making good or laying in treches complete all as specified and directed. Make:- Astral / Ashirwad / Supreme Note: Site of work is hilly terrain which is not approachable by road.
12
-
-
... More
S&F in repair cast iron foot valve, flanged end type confirming to IS-4038, ISI marked alongwith fixing accessories such as suitable size nut, bolts, washer & rubber gasket of following size :-
Make:- Kirloskar/L&T/Bir/ Zoloto/Leader
-
-
-
... More
100 mm dia complete all as specified and directed.
1
-
-
... More
80 mm dia complete all as specified and directed.
1
-
-
... More
Taking down non functional electric induction motor of any size and capacity from water supply installation at zero/ Ist/ IInd stage pump house which are not approachable by road and 3rd stage/ Jharapani/ 2nd lift/ 15 LGLN pump house, decoupling motor from pump and cutting, removing burnt out copper winding and re-winding with super enamelled copper wire of suitable gauge conforming to IS 13730-0-6 (2012) and reassembling/couple back complete and transporting back to its original location and making necessary allingnment and electric connection all as directed at site by Engg-in-Charge. Note :- Any other spare parts, if needed to be replaced shall be measured & paid as supply only separately under respective item of Sch 'A'/ BOQ.
40
-
-
... More
Supply only following spare parts suitable for above mentioned complete all as specified and directed :-
-
-
-
... More
Stainless steel bush/shaft sleeve for suction/delivery for 75 HP centrifugal multistage horizontal pump with bore as per sample complete all as specified and directed.
1
-
-
... More
Stainless steel bush/shaft sleeve for suction/delivery for 100 HP centrifugal multistage horizontal pump with bore as per sample complete all as specified and directed.
1
-
-
... More
Cast steel bearing lock nut with washer as per sample for 100HP Pump complete all as specified and directed.
1
-
-
... More
Roller bearing NU-207 for 100HP Pump complete all as specified and directed.
1
-
-
... More
S&F Bush type flexible cast iron flanged coupling with finished bore and keyway as per sample for centrifugal Pump set complete all as specified and directed.
2
-
-
... More
S&F Rubber bush along with pin (high tensile nut bolt) as per sample for flexible coupling complete all as specified and directed.
8
-
-
... More
S&F in repair water pressure guage of pressure 0-40 kg/sqcm with dial size of 100 mm dia along with ball valve of suitable size complete all as specified and directed.
Make:- Kirloskar/H-Lal/L&T
1
-
-
... More
M&L in repair for fabrication and fixing of mild steel, plain, black sheet of thickness 1 mm for making coupling guard, cut to size, holes punched, including round headed screws, clout nails or rivets, bending or turning up, mitred angles, etc. as required complete all as specified and directed.
1
-
-
... More
Supply, laying & testing in repair of PVC insulated unarmoured and unsheathed Single core copper conductor flexible cable of following size :-
Make:- Grandlay/ Havells / Gloster
-
-
-
... More
25 Sqmm Cable complete all as specified and directed.
50
-
-
... More
35 Sqmm Cable complete all as specified and directed.
50
-
-
... More
S&F in repair electronic star delta timer 3-30 seconds type ST100,160-500Volts, 50Hz complete all as specified and directed. Make:- L&T / Schneider / Legrand
1
-
-
... More
S&F in repair Power Contactor 95 Amps complete all as specified and directed.
Make:- L&T / Schneider / Legrand
1
-
-
... More
S&F in repair auxiliary contact block side mounting with 1 No + 1 NC commplete all as speciffied and directed. Make:- L&T / Schneider / Legrand
1
-
-
... More
S&F in repair motor protection relay D2MPR commplete all as speciffied and directed.
Make:- L&T / Schneider / Minilac
1
-
-
... More
S&F in repair Phase failure relay with under and over voltage settings complete all as specified and directed.
Make:- L&T / Schneider / Minilac
1
-
-
... More
M&L for cleaning of semi UG Sump of following capacity after emptying the sump with help of Pump, removing all mud, waste etc complete, scrubbing the entire sump inside with wire brush, washing the entire sump from inside with water and subsequently with bleaching powder solution and painting inside with two coats of lime wash and writing date of cleaning with white paint after making a block of black paint complete all as specfied & directed :-
-
-
-
... More
3 Lakh/2.5 lakhs gallon capacity complete all as specified and directed.
1
-
-
... More
2 Lakh/ 1.5Lakh/ 1.4 Lakhs gallon capacity complete all as specified and directed.
3
-
-
... More
50000 /45000/40000 gallon capacity water storage tank complete all as specified and directed.
3
-
-
... More
10000 gallon capacity water storage tank complete all as specified and directed. Note for item No 47 to 50 :-Date of cleaning shall be painted with synthetic enamel paint on sump all as directed.
2
-
-
... More
M&L for Collecting water sample from water supply installation of lansdowne and carry out water quality test (pH, TDS, Turbidity, Alkalinity, Total hardness, Fluoride, nitrate, Sulfate, RFC, Colour, Conductivity, Chloride, odour, Total coliform, E.Coli) from recognised government organisation complete all as specified and directed.
5
-
-
... More
Taking down carefully copper/aluminum point wiring (light/fan/socket power) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc. all as specified and directed.
42
-
-
... More
Dismantling and taking down u/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified & as directed.
35
-
-
... More
Dismantling and taking down old U/S TPN DB/SPN DB any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified.
6
-
-
... More
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continuous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed rigid PVC conduit(ISI marked) ,duly cutting chases & concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) including metal flush box made of GI sheet and white cover with making good the disturbs surfaces of wall/floor/ceiling complete all as specified and directed for the following.
Make:- Havells / Gloster / Grandlay
Note: Flush box and cover plate should be of same make all as approved for switches/sockets.
-
-
-
... More
One light/fan/bell point controlled by one No modular type switch 6 Amps single pole one way complete all as specified and directed.
30
-
-
... More
One 3 pin 6 Amps socket outlet on same board controlled by one, one way 6 Amps modular switch complete all as specified and directed.
4
-
-
... More
One socket outlet 5/3 pin 6 Amps controlled by one modular switch on independent board complete all as specified and directed.
4
-
-
... More
All as per item No 55 here-in-before but wiring with 2.5 sqmm single core multi stranded copper condcutor 1100 V grade PVC insulated FRLSH but unsheathed single core for 16 Amps power point on independent board and 2.5 sqmm FRLSH cable as earthwire complete all as specified and directed.
Make:- Havells / Gloster / Grandlay
4
-
-
... More
S & F switch Modular single pole, one way 6 Amps , 1 module, 230 volts, 50 hz complete all as specified and directed. Make:- Legrand / Schneider Zencello / Anchor
38
-
-
... More
Supply and fix Modular switch 1 way 16 Amps, 1 module, 230 volts, 50 Hz complete all as specified and directed. Make:- Legrand / Schneider Zencello / Anchor
4
-
-
... More
Supply and fix Modular Socket outlet, 6A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed. Make:- Legrand / Schneider Zencello / Anchor
8
-
-
... More
Supply and fix Modular Socket outlet, 16A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed. Make:- Legrand / Schneider Zencello / Anchor
4
-
-
... More
S&F ceiling rose 3 terminal / PVC/ polycarbonate, isolated body complete all as speccified and directed.
Make:- SSK / HPL / Anchor Penta
40
-
-
... More
Supply and fixing Fancy angle holder Metal ring insulated body with back plate, suitable for batten fittings complete all as specified & directed. Make:- SSK / HPL / Anchor Penta
6
-
-
... More
S & F LED Bulb 10 Watt (cool day light) having colour temp 6500 K and lumen output 950 suitable for "B-22 type to fix on batten holder complete all as specified and directed.
Make:- Crompton / Bajaj / Orient
10
-
-
... More
S&F MCB DB SPN 8 way, 240 volts in sheet steel enclosure.double door type including taking down old DB complete all as specified and directed. Make:- Schneider / L&T / Legrand
3
-
-
... More
S&F MCB DB SPN 4 way 240 volts rated copper busbar in sheet steel enclosure double door type complete all as specified and as directed.
Make:- Schneider / L&T / Legrand
3
-
-
... More
S&F MCB , SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed.
Make:- Schneider / L&T / Legrand
20
-
-
... More
S&F MCB, SPN, AC, 240 volts of 40 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified and directed.
Make:- Schneider / L&T / Legrand
6
-
-
... More
S& F surface mounted LED luminiare, 20 watt, 4 Feet with all accessories having aluminum extruded channel with diffuser for glare free light, high lumen output, driver PF 0.90 having over voltage protection upto 400 volts and lumen efficiency 120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose all as directed. Make:- Crompton / Bajaj / Orient
20
-
-
... More
Supply and fix LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF 0.95 having over voltage protection upto 440 volt, surge protection level 10 KV, thermal short circuit protection THD 10% made up of long life LED chip (SMD) in modular with Ra 70, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminaire efficiency 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500° K including fixed on wall with 1.2 mtr 32 mm GI pipe bracket & 02 Nos MS clamp made out of F1 40 x 6 mm or as directed including connecting with 1.5 sqmm , 3 core, PVC insulated copper conductor cable 1100 Volt grade from ceiling box to light complete all as specified and as directed by Eng-in-Charge (i) The firm has to given warranty of street light fittings including driver minimum for 03 years for any defect developed during the period. (ii) The contractor Shall submitt the third Party LM 79 report from any NABL approved laboratory (iii) The fiitting should have BIS , CRS No(iv) Connection to luminaire shall be done in suitable PVC connector within the bracket/luminaire end and are inclusive in above.
Make:- Crompton / Bajaj / Orient
4
-
-
... More
Supply and fixing sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 25mm dia or more medium grade surface/concealed in wall along with 6.00 Sq mm PVC insulated unsheathed copper conductor cable (FR LSH) as earth wire and wire connected with main earth dolly including cutting chases and making good disturbed portion complete all as specified and directed. Make:- Havells / Gloster / Grandlay
Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length.
35
-
-
... More
Supply and installation of solar all-in-one street lighting with smart intergrated solar street light with built in mono crystalline Solar Panle, lithium Feero phospate (LiFeP04) battery, MPPT charge controller and PIR Sensor with color temperature range 6000-6500K of power rating 25 watt, panel capacity 45W and battery capacity 21 AH with autonomy for 03 days complete with 5-6mtr hot dip galvanized octagonal smart pole duly grouted in PCC 1:2:4 (nominal mix) type B2 (Using 40mm graded crushed stone aggregate) as in foundation and all other works as required at site during execution as per manufacturer's recommendation, complete all as specifed and directed. Make : Crompton/Bajaj/Havells. Note : Minor varioation in tech specification is permissible as per manufacturer standard design.
2
-
-
... More
Supply and fixing LED flood light 120-150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specifed and directed.
Make : Crompton/Bajaj/Orient
4
-
-
... More
S&F in replacement of MCCB 4 pole, 415 volt , adjustable thermal and magnetic release type 400 Amp breaking capacity 36 KA complete all as specified and directed. Make:- Schneider / L&T / Legrand
1
-
-
... More
S&F in replacement of MCCB 4 pole, 415 volt , adjustable thermal and magnetic release type 250 Amp breaking capacity 36 KA complete all as specified and directed. Make:- Schneider / L&T / Legrand
1
-
-
... More
S&F in replacement of MCCB 4 pole, 415 volt , adjustable thermal and magnetic release type 160 Amp breaking capacity 36 KA complete all as specified and directed. Make:- Schneider / L&T / Legrand
1
-
-
... More
S&F in replacement of MCCB 4 pole, 415 volt , adjustable thermal and magnetic release type 100 Amp breaking capacity 25 KA complete all as specified and directed.
Make:- Schneider / L&T / Legrand
1
-
-
... More
Supply & Fix On load Changover switch in sheet metal enclosure rating of 400 Amp after taking out old unsv changever and cable connection complete all as specified and directed. Make:- Havells / L&T / Legrand Note:- The work will be carried out at 1st Stage Pump House which is not connected by road.
1
-
-
... More
M&L for installation of 3D Acrylic letter board of various sizes consisting of following specification :- (i) Frame work for glow sign board to be made with MS square pipe of size 25x25x2.6mm cut to required size incl welding, drilling holes, bending etc and painted with two coats of synthetic enamel paint over one coat of red oxide primer complete for required size complete. (ii) ACP Sheet of 0.8 mm thickness cut to required size and fixed by screwing, drilling holes, bending etc from all sides of the board except front. (iii) Acrylic sheet milky white colour 3.0mm thickness cut to required size and fixed in front. (iv) Matter for writing, Colour, type and size of font will be approved by GE. (v) Creating 3D Acrylic letters from the design approved by GE, using a laser cutting machine followed by extrading in 3D using a metthod called skirting. (vi) LED modules fitted in the hollow space beneath the 3D letters or logo of signboard with necessary electric fittings and connection from existing pole / DB complete. (vii) MS square pipe for support 100x100x5mm shall be used for support of board and painted with two coats of synthetic enamel paint over one coat of red oxide primer. Note:- (i) Grouting the support pipe in Brickwork/RCC pillars using (1:3:6) PCC shall be considered in quoted rate for this item. (ii) The support MS Square pipe to be fixed in ground/pillar all as per specified and as directed. (iii) Sintex junction box fixed with 1 MCB SP of capacity 06 to 10 Amp for ON/OFF control of glow sign board and cable for making connection from existing pole / DB / Busbar to Junction box deemed to be included in the rates quoted.
4
-
-
... More
Supply only Calcium Hypochlorite Grannulas (65%-70%) complete all as specified and directed.
Make:- Altoch-ch / Aquafit / Puri Chlor
360
-
-
... More
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. (earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 32x6 mm GI strip as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI strip upto 7.5 mtrs long with 40 mm dia medium grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.
(ii) Cost of additional GI strip more than 7.5 mtrs will be measured and paid seperately under relevant items.
4
-
-
... More
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required but 32x06mm galvanised iron strip incl taking down old strip complete all as specifed and directed.
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%