Military Engineer Services Tender
View complete overview of Uttarakhand MES Tender
Military Engineer Services - MES Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date1 Nov 2024
Closing Soon15 Nov 2024
Tender Amount₹ 7,98,000
Costs
EMD
₹ 15,960Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_677729_2Tender No
8924/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc and removing unserviceable material,outside cantt area distance not exceeding 1.5 KM complete all as specified and directed.
65
-
-
Material & labour for Rendering 10 mm thick CM 1:6 on stone masonry surfaces or concrete surfaces complete all as specified and directed.
65
-
-
M&L for preparation of newly plastered surface of internal wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge.
Note:- (i) The new surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper The cost of all material T&P and labour required for preparation of surface are deemed to be included in the rates quoted . (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture.
(iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building.
(v). The colour / shade will be all as approved by GE / AGE (I)
65
-
-
M&L for complete removal of existing painting and preparation of old plastered surface of internal wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper using roller all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge.
Note:- (i) The new surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper The cost of all material T&P and labour required for preparation of surface are deemed to be included in the rates quoted . (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture.
(iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building.
(v). The colour / shade will be all as approved by GE / AGE (I)
50
-
-
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including Screed bed or bedding layer in CM : 1:4, 15 mm thick complete all as specified and dierected
40
-
-
Material & Labour for 300X450X 8 to 9 mm thick joint free light coloured glazed ceramic tiles of any design and pattern, as in dado etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects. including 10 mm thick in cm (1:4) backing coat and including dismantling of old tiling and removing old unserviceable materials from the distance not exceeding 1.5 Km complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by Engineer in Charge.
20
-
-
Material & Labour for 600x600x 7 to 8mm thick Joint free Non-Skid light coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (Square/rectangular) area of each tiles exceeding 0.18 Sqm and not exc. 0.38 Sqm, in floor etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects. including 15 mm thick screed bed in cm 1:6 including dismantling of existing old tile. complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by EIC.
15
-
-
Dismantling of wall and ceiling board (fibre,insulation etc) or insulation board ,slabs,blankets, any thickness incl cover fillets complete all as specified and directed.
70
-
-
S&F in repairs E-boards, ceiling, 4 mm thick with J framed work with main Tee of size 24 x 28.5 mm made out of PGI sheet .3 mm thick double at web and single at flange, flange coverd with powder coated sheet 0.25 mm thick and wall angle 24 x 24 x .45 mm powder coated for ceiling , ceiling boards 60cm x 60cm x 4mm thick , suspended with GI wire 2mm dia and 2m average length with adjustable hanging device complete including plugging in brick/stone walls with steel rawl plug @ 600 mm C/C Ceiling board shall be pressed to the ceiling tee with staple clips at all four sides and making good all the disturbed portion by painted with two coats of oil bound distemper complete all as spd & directed by Eng-in-Charge.
70
-
-
Taking down Chowkats with shutter exceeding 1.5 Sqm . but n . exc 4.00 Sqm each (Without taking off shutters from the frames) complete all as specified and directed.
2
-
-
Taking down chowkats with shutter n. exc 1.5 sqm each. (without taking of shutter from the frame) complete all as specified and directed.
3
-
-
S&F 30mm thick molded WPC factory made 1005 decorative type, moulded, solid door shutter (confirming as per IS: 4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with wood grain texture and back side plain with density not less than 600kg/cum manufactured by an ISO : 9001-2015 certified company complete all as specified and directed.
Note: The door should be water proof, termite proof, termite proof, fire retardent and having screw holding capasity.
3.4
-
-
S&F 125mm x 65 mm single rebated facotry made 100% solid WPC Door frame made from 100% LEAD Free (Single extruded process) material with density 780 kg/cum and manufactured by an ISO : 9001-2015 certified company , all as per specification complete all as specified and directed.
Note: The door frame should be water proof, termite proof, fire retardent and having excellent screw holding capacity.
9.5
-
-
S & F Butt hinges, 100 mm long stainless steel non magnetic ( ISI marked ) complete all as specified and directed..
6
-
-
S&F 300mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified and directed.
2
-
-
S&F 200mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and directed.
2
-
-
S & F Aluminium handles cast type anodised of size 150mm long ISI marked complete all as specified and directed.
4
-
-
S & F structural rolled mild steel as in roof trusses (framed) purlins crane gantries, rail and fastening and heavy brckets framing (beam, tee angle, channel or flat section) including distance pieces, cleats etc or FE-290 9gde E-165) complete all as specified and directed.
200
-
-
S & F structural rolled mild steel as in roof trusses (framed) purlins crane gantries, rail and fastening and heavy brckets framing (beam, tee angle, channel or flat section) including distance pieces, cleats etc or FE-290 9gde E-165) complete all as specified and directed.
200
-
-
M & L preparation old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
23
-
-
M & L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed.
20
-
-
Providing and fixing windows & ventilators fabricated from Rolled Formed GI Section made of Galvanised steel colour coated(PPGI Sheets) (Base steel as per IS 513 ‘’D’’ quality. Galvanised as per IS 277 with Zinc of 90 Gsm/SqMt w. PAINT: Pre-Painted sections should be with primer coat of epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick.GI Section of 0.58mm thick in Double rebate windows in which both glazed shutter and flymesh shutter, 74 X 60mm outer frame , Mullion 72 x 49mm, Glazed shutter 48 x 22mm, Flymesh 41 x 22mm, Beading with round ends for Glass Fixing 12 x 12mm in fixed portion and the outer frame and mullions to have rebate for glazed/gauzed shutters the sections cut to length metre joined with corner PolyVinylChloride brackets centre mullion fixed with PolyVinylChloride Mullion caps . Glass of 4mm thick plain float glass fitted with Ethylene Propylene Diamine Monomer in glazed shutter and wiremesh of Stainless steel of 36 guage to fix mesh in mesh shutter using VC Black Gypsum Drywall screws and Spoon profile of 0.58mm GI Sheet. Corners of the windows should be joined with corner brackets made of polyvinylchloride with crca of zinc phosphate coat.Each glazed shutter and fly mesh shutter shall be provided with SS Pivot Hinges 2 in each, PolyVinylChloride handle 1 in each and Powder coated Peg stay in Glass shutter.Window shall be provided with Powder coated MS Grill/Guard Bars made of 10mm MS Sq Bar welded to 6 x 12mm MS Flat with countersunk holes at both vertical ends . Gap between the bars should not be more than 150mm . Window frames shall be fixed to brick / concrete masonry by using nylon self expension caps & 75/100 mm MS screws after drilling in walls. VC Black Gypsum Drywall screws should be used while fixng corner brackets, stay, hinges, mullion caps of windows.
1.9
-
-
Demolition of brick or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dresse stonework and precast concrete articles complete all as specified and directed.
2
-
-
M & L for brickwork with subclass "B" bricks straight or curved on plan exc. 6m mean radius in cement mortar (1:6) all as specified and directed.
2
-
-
M & L for plain cement concrete Type B-1(1:2:4) (using 20 mm graded stone aggregate), cills, steps, parapets , copings,bond stone, bed plates, hold fast and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
0.7
-
-
M & L for cement concrete type C1, 1:3:6 (20mm graded aggregate) 75mm thick as in plinth protection complete all as specified and directed.
15
-
-
M & L for cement concrete 1:4:8 type D-2 (75mm thick) using 40mm graded aggregate as in sub base complete all as specified and directed.
35
-
-
M&L 15 mm thick in cement mortar 1:6 screed bed or bedding layer of mortar for laying floor finishes complete all as specified and directed.
35
-
-
M&L Chequered cement concrete tiles 30cm x 30cm x 30mm thick, set, jointed and pointed in neat cement slurry in floors with gray cement pigments complete all as specified and directed.
35
-
-
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
4.2
-
-
M&L MS plates (plain or cqequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conferming to Fe 410-W (Gde-E-250 quality A)complete all as directed.
251
-
-
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Complete all as specified and directed.
250
-
-
S&F Rotational moulded polyethylene water storage tank including, plastic lid cover, triple layered,white colour, cylindrical vertical with closed top hoisted and fixed in position of capacity 5000 ltrs including making connections, complete all as specified in SSR Part I complete all as specified and directed.
1
-
-
S&F Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings(such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs,unions etc.) of nominal bore 20mm, complete all as specified and directed.
15
-
-
S&F Stop valve 20mm dia bore,cast copper alloy, screwed down, high pressure, with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
2
-
-
S&F Stop valve 15 mm dia bore,cast copper alloy, screwed down, high pressure, with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
2
-
-
Taking down carefully copper/aluminum point wiring (light/fan/socket power) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc. all as specified and directed.
34
-
-
Taking down carefully TPN DB/ MCB DB complete, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc. all as specified and directed.
1
-
-
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one modular switch with 6 Amp single pole one way, 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continuous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed rigid PVC conduit(ISI marked) ,duly cutting chases & concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) including metal flush box made of GI sheet and white cover with making good the disturbs surfaces of wall/floor/ceiling complete all as specified and directed.
Note: Flush box and cover plate should be of same make all as approved for switches/sockets.
15
-
-
All as per item No. 42 but one 3 pin 6 Amps socket outlet on same board controlled by one, one way 6 Amps modular switch complete all as specified and directed.
3
-
-
All as per item No. 42 but one socket outlet 5/3 pin 6 Amps controlled by one modular switch on independent board complete all as specified and directed.
11
-
-
All as per item No 42 here-in-before but wiring with 2.5 sqmm single core multi stranded copper condcutor 1100 V grade PVC insulated FRLSH but unsheathed single core for 16 Amps power point on independent board and 2.5 sqmm FRLSH cable as earthwire complete all as specified and directed.
5
-
-
S & F switch Modular single pole, one way 6 Amps , 1 module, 230 volts, 50 hz complete all as specified and directed.
29
-
-
Supply and fix Modular switch 1 way 16 Amps, 1 module, 230 volts, 50 Hz complete all as specified and directed.
5
-
-
Supply and fix Modular Socket outlet, 6A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed.
14
-
-
Supply and fix Modular Socket outlet, 16A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed.
5
-
-
Supply & fixing fancy lamp holder, insulated body ISI marked with back plate for batten fitting complete all as specified & directed.
2
-
-
S&F ceiling rose 3 terminal / PVC/ polycarbonate, isolated body complete all as speccified and directed.
13
-
-
S&F MCB DB SPN 8 way with 200 amps 240 volts rated copper busbar in sheet steel enclosure.double door type complete all as specified and directed.
1
-
-
S&F MCB , SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed.
6
-
-
S&F MCB, SPN, AC, 240 volts of 40 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed.
1
-
-
S& F surface mounted LED luminiare, 20 watt 4 feet with all accessories having aluminum extruded channel with diffuser for glare free light, high lumen output, driver PF 0.90 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circuit protection THD10%, made up of long life LED chips (SMD) in modular with Ra70 and lumen efficiency 120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose all as directed.
9
-
-
S & F LED Bulb 10 Watt (cool day light) having colour temp 6500 K and lumen output 950 suitable for "B-22 type to fix on batten holder complete all as specified and directed.
2
-
-
Supply and fix LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF 0.90 having over voltage protection upto 440 volt, surge protection level 10 KV, thermal short circuit protection THD 10% made up of long life LED chip (SMD) in modular with Ra 70, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminaire efficiency 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500° K including fixed on wall with 1.2 mtr 32 mm GI pipe bracket & 02 Nos MS clamp made out of F1 40 x 6 mm or as directed including connecting with 1.5 sqmm , 3 core, PVC insulated copper conductor cable 1100 Volt grade from ceiling box to light complete all as specified and directed.
4
-
-
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4mm GI Wire check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI strip upto 7.5 mtrs long with 15 mm dia medium grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover.
(ii) Cost of additional GI strip more than 7.5 mtrs will be measured and paid seperately under relevant items.
1
-
-
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspen ded by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat of size 16 Sqmm complete all as specified and directed.
45
-
-
Dismantling and refix in repairs Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
3
-
-
Dismantling and refix in repairsTest point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
2
-
-
Dismantling and refix in repairs Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
30
-
-
Supply, fixing, laying, jointing & testing of galvanised iron water tubing of 15 mm bore, 'medium grade' conforming to IS-1239 with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc as required complete fixed checknuts, caps, plugs etc as required complete fixed to walls and ceilings, laid in trenches/under floor/under road or floors complete all as specified and directed.
35
-
-
All as per item No. 63 but 25 mm bore complete all as specified and directed.
35
-
-
All as per item No. 63 but 40 mm bore complete all as specified and directed.
150
-
-
Supply & fixing of gun metal globe or gate valve of 15 mm bore with iron wheel head, both ends screwed for iron pipe, conforming to IS 778 complete all as specified and directed.
2
-
-
All as per item No. 66 but 25 mm bore complete all as specified and directed.
2
-
-
All as per item No. 66 but 40 mm bore complete all as specified and directed.
5
-
-
Excavation in trenches in soft/disintegrated soil not exc 1.5 m wide and not exceeding 1.5m in depth for laying UG cable/foundation etc complete all as specified and directed.
19.68
-
-
Returning filling in soft/disintegrated soil including spreading levelling watering and well ramming in layers n.exc 25cm each layer complete all as specified and directed.
17.52
-
-
Removal of excavated surplus soft/disintegrated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
2.16
-
-
Supply, install, testing and Fixing Monoblock Pump Set of 2 HP (1.5 KW) with Energy efficient Motor maximum working pressure 3.0 Kg/cm2, 50 Hz, 180-240 Volts stainless Steel (SS-410) shaft, cast iron impeller, copper winding and High pressure die-cast CI body complete all as specified and directed.
1
-
-
S&F service cable 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended with insulating hanger not more than 1 mtr apart including 4 mm dia suspension wire alongwith 10 sqmm twin core flat cable all as specified and directed.
20
-
-
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 10 Amps complete all as specified and directed.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%