Military Engineer Services Tender
View complete overview of Uttarakhand MES Tender
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Nov 2024
Closing Date7 Dec 2024
Tender Amount₹ 49,56,000
Costs
EMD
₹ 99,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684117_1Tender No
9981/DDN/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
(c) Old Anarwala Md Accn/Map qtrs of upper camp and 3 Punjab incl AW Pump house feeder (Approximate 4 KM go and back )
40
-
-
(d) Feeder 2 MW SPV Plant to MRS Anarwala(Approx 4.0 KM go & back)HT U/G Cable with 08 section point terminal on pole
15
-
-
(e ) Feeder from 33 MRS Anarwala to GuchchU Pani (UPCL) Sub station 33 HT U/G Cable with 04 nos section point terminal on single pole (Approx 1.5 KM go &back)
10
-
-
(f) Attending fault/ breakdown in LT Over Head line/ LT UG Cable/Service connection Cable/AC Connection due to any reason including removing of fault, and restoring the electric supply whole Anarwala area incl MH
450
-
-
S&F Tinned copper fuse wire of different cap & size as required all as directed
5
-
-
S&F Disc type Insulator (three disc in series assembly) porcelain vitreous, white brown or green 145 mm height and 255 mm dia ball and socket type with tension clamp galvanized iron nut bolts & washers for conductors working pressure 33000 volt grade complete all as directed incl disconnection and taking down existing complete
6
-
-
S&F Pin type insulator porcelain vitreous, white brown or green 150mm height and 150mm dia including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nut for conductor working pressure 33000 volt grade complete all as directed incl disconnection and taking down existing complete
15
-
-
S&F Disc type insulator (single disc assembly) porcelain vitreous, white brown or green 145 mm height and 255 mm dia ball and socket type with tension clamp galvanized iron nut for conductors working pressure 11000 volt grade complete including disconnection and taking down existing insulator complete all as specified and directed.
3
-
-
S&F Pin type insulator porcelain vitreous, white brown or green 150mm height and 150mm dia including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nut for conductor working pressure 11000 volt grade complete including disconnection and taking down existing insulator complete all as specified and directed.
6
-
-
S&F Insulator Post type porcelain vitreous, white brown or green 150mm height and 150mm dia including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nut for conductor working pressure 11000 volt grade complete with fuse clamps including disconnection and taking down existing insulator complete all as specified and directed.
6
-
-
Dismantling and taking out old unserviceable cross arms and M&L for cross arms, bracing, supports clamps back plates, gantry bay structure etc fabricated from structural steel section such as suitable I section channel ISMC angle iron and flat iron GI nut, bolt & Washers with welding, cutting, drilling hole etc for insulator bolts clamps in any shape and size including one coat of red oxide and two coats of epoxy heat resistant paint all complete all as specified and directed.
2
-
-
S&F in repair of Aluminium conductor steel reinforced (ACSR) for over head line of any size stringing and jointing on poles fixed to insulator including, binding wires pointing sleeves, aluminium tap and PG clamp etc complete all as specified and as directed including taking out old u/s ACSR conductor any size and type
2.5
-
-
S&F Indoor type single phase Epoxy cast potential transformer of ratio 33000/rt3/110/rt3,class .2 s, burden -25 VA,SV/HSV : 33/36 KV,ILV:70 KV,
Connection : 'E' Earthed as per IS : 3156/1992
MAKE : Adhunik yantra udhyog/CG/AE
3
-
-
S&F Indoor type single phase Epoxy cast current transformer of ratio 60/1,
class : 0.2s,burden : 2.5 VA,STC : 13.1,KA : 1.0 sec,SV/HSV : 33/110V,
ILV ; 70 KVp as per IS :2705, MAKE : Adhunik yantra udhyog/CG/AE
3
-
-
S&F Indoor type single phase Epoxy cast current transformer of ratio 100/50/1+1A,class : 1.0,burden : 15 VA,STC : 18.4 at 1 Sec ,SV/HSV : 11 KV/110V,ILV ; 70 KVp as per IS :2705 , MAKE : Adhunik yantra udhyog/CG/AE
3
-
-
Auxiliary Relay 30 ABC,24 Volt DC ,PC : B33 08058
For 33 Volt Control & Relay panel ( tranformer cum feeder)
1
-
-
Auxiliary Relay 30 DEF,24 Volt DC ,PC : B33 08058
For 33 Volt Control & Relay panel ( tranformer cum feeder)
1
-
-
Supervision Relay for trip relay ,95 T,24 V DC,PC : XR VED 08999
for 33 Volt Control & Relay panel ( tranformer cum feeder)
1
-
-
S&F PT 33 KV outdoor type single Phase oil cooled PT of ratio 33/rt3/110/rt3/110rt3 class 0.50-3, burden 50 VA, insulation level 70/170 KV voltage factor 1.2 Cont and 1.9 for 30 second confirming to IS 3156 including taking down old unserviceable PT complete all as specified and directed incl taking down existing old u/s complete..
3
-
-
S&F CT 33 KV outdoor type single Phase oil immersed self cooled having CT ratio 50/1 with copper double wound dual ratio to be fitted on LV side of Transformer including taking down old unserviceable CT complete as per IS 2705 accuracy class-I burden 15 VA separate core for metering & separate core for protection duly calibrated according to load all as specified and directed incl taking down existing old u/s complete.
3
-
-
S&F in replacement of unserviceable station class type lightning arrestor suitable for 33 KV discharge current 65 KA fixed on existing steel structure including connection with earth strip conforming IS 3070 (Part -3) 1983 Class 'A' complete all as specified and directed incl taking down existing old u/s complete.
3
-
-
S&F in replacement of one set of 3 Pole micro processor based feeder protection relay with instantaneous 2 Nos over current (50, 50N) element and 1 No Instantaneous earth fault (50, 50N) (o/c setting 50% - 200% and earth fault setting 20 % - 80% having large LCD display of all the parameters ie all three phase current at a time, type of fault, fault history etc operating voltage 110 Volts DC suitable for 11 KV indoor VCB panel including calibration of relay accordingly complete all as specified and directed incl disconnection and taking out existing complete and making necessary modification in existing wiring (if any required).
2
-
-
S&F in replacement of one set of 3 Pole Over current & Earth fault relay operating voltage 110 Volts DC suitable for 11/ 33 KV indoor VCB panel including calibration of relay accordingly complete all as specified and directed incl disconnection and taking out existing complete and making necessary modification in existing wiring (if any required).
3
-
-
S&F in repair/ replacement following parts of HT VCB 11 KV, AC 3 phase, 50 HZ indoor type & 33 KV Out door VCBs/RMUs for complete as per existing make all as specified and directed incl disconnection and taking down existing complete
-
-
-
(a) Spout set (set of three) shower and rose contacts.
3
-
-
(b) Auxiliary Contactor.
2
-
-
© Closing Coil 110/30 DC volts.
2
-
-
(d) Shunt tripping Coil 110/30 DC volts.
2
-
-
€ Relay (PLA/Defferencial etc) 30/110 V DC,6A 250 V AC
2
-
-
(f) Tripping lever.
1
-
-
(g) Charging lever.
1
-
-
(h) Changing gear for VCB.
1
-
-
(j) Tripping pin.
2
-
-
(k) Spring Charging Motor complete 220 Volts.
2
-
-
(l) Vaccume interrupter bottle as per sample suitable for 11//33 KV VCB at MRS.
3
-
-
(m) Digital 3 line display multifunction meter having features to measure Volt Ampere power factor active load reactive load etc.
2
-
-
(n) HRC fuse 2/5/10 Amp complete all as specified and directed
10
-
-
(p) Digital Volt meter 11/33 KV 3 phase range of accuracy 0.5 complete all as specified and directed
2
-
-
(q) Digital Amp meter 11KV, 3 phase range of accuracy 0.5 for CTR 100/50/1+1 A complete all as specified and directed
2
-
-
(r ) Space heater
5
-
-
(s) Thermo state
5
-
-
M&L for calibration make HT VCB indoor type 11 KV with calibration of all protective devices or relay according to load with & incl replacement of fuse, indicators, selector switches, meters or minor repair to wiring connector block etc all as specified and directed by E-in-Charge.
Note:- (i) Calibrartion is to be done by auth service person.
(ii) No Extra payment will be made after repeated calibration carried out throughout contract period.
12
-
-
Supplying in replacement of existing unserviceable control cable including laying or fixing with saddles or cable tie etc, jointing and testing LT PVC insulated copper conductor armoured electric power cable ISI marked with multistranded copper conductor heavy duty 1100 volts grade of 2.5 Sq mm 4 core complete all as specified and directed incl disconnection and taking down existing complete.
150
-
-
Supply & fixing powder coated or hot dipped GI preforated type cable trays of size 100mm wide x 40mmx1.6 mm thick fixed to wall or iron gantery inclding all the try accessories,supports,bends,ankor fasteners,GI hardware etc
30
-
-
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in soft/loose soil complete all as specified and as directed.
450
-
-
Excavation in trenches not exceeding 1.5m wide and exc. 1.5m depth and getting out in soft/loose soil complete all as specified and as directed.
15
-
-
Removing of excavated soil to a distance n exc 50 mtr and deposited where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
184
-
-
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft/loose soil complete all as specified and as directed.
281
-
-
Supply and laying dry river sand filling for cable protection in trenches/cable ducts complete all as specified and as directed. (Note : only punned thickness shall be measured).
177
-
-
M&L sub class B bricks locally available of size 23 x 11.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable complete.
11300
-
-
M&L for un-reinforced precast concrete cable cover HV type 1, flat size 300mmx180mmx40mm as protection to under ground cable laid dry and flat adjoining each other complete all as directed .
2777
-
-
S & Laying LG GI Pipe of size 150 mm bore on pole or road crossing for cable protection with complete making good surface of road as directed
15
-
-
S & Laying LG GI Pipe of size 100 mm bore on pole or road crossing for cable protection with complete making good surface of road as directed
20
-
-
S & Laying LG GI Pipe of size 40 mm bore on pole or road crossing for cable protection & earthing strip protection with complete making good surface of road as directed
30
-
-
S & Laying LG GI Pipe of size 15 mm bore on pole or road crossing for cable protection & earthing strip protectionwith complete making good surface of road as directed
40
-
-
M&L for spraying of agricultural based chemical inside the installation to control the growth of unwanted herb, shrubs etc incl cutting, removing the vegetation growth & surface dressing all around the LT transformer installations /LT/Capacitor bank panel Board area and two/ four HT pole structure to keep installation always clean and tidy condition. Note:-Installations shall be kept clean by removing shrub/bushes etc throughout contract period and same shall be measured & paid only once after completion of contract.
3000
-
-
M&L for removing the herb, shrubs, creepers etc on the LT/HT Poles(sigle/two/four) the to keep poles/structures always clean and tidy condition. Note:- All the Poles shall be kept clean throughout contract period by repeatedly by removing the grass / shrubs as many times reqd depending on the growth of grass measurement will be measured & paid only once throughout contract period only once.
25
-
-
Material and labour for stone graded course aggregate of 63mm grade nominal size with out any vegitation or chemical including levelling/spreading surrounding HT/LT 2/4 pole structure,LT/HT panel complete all as specified & directed
15
-
-
Taking out of HT /LT cable ,11KV OR 1.1 KV of any size from ground or poles etc and testing for serviceability and kept aside for reuse including proper rolling, loading unloading, transportation etc complete all as specified and directed. Note:- Earth work for the same shall be measured and paid separately.
300
-
-
Laying only of existing serviceable cable HT/LT ,11KV OR 1.1 KV in ground retrieved against item No 39 here and before complete including unrolling, unloading, transportation etc testing connections complete all as specified and directed.
200
-
-
M&L PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for Post/Pole/ FPB /Transformer plinth plateform etc including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed.
2.9
-
-
M & L PCC (1:3:6) type C-1 (with using 20 mm graded stone aggregate) as coping of pole/FPB/TFR plinth plateform including necessary form work as required complete as directed
1.5
-
-
Material and labour for fault detection in UG HT cable of any size any type at any depth with fault locator incl material T&P required for the same and testing complete all as specified and directed.
Note 1- Joint, excavation laying only of cable shall be measured and paid seperately
2. Each fault shall be treated as one job and contractor have to address the said fault immediately.
2
-
-
M & L for HT under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 33000 volts (earthed) grade copper sheet wrapped cross sectional area 240 sqmm 3 core cable complete all as specified and directed.
250
-
-
M & L for HT under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts (earthed) grade copper sheet wrapped cross sectional area 95 sqmm 3 core including all as specified and directed.
150
-
-
All asper item no 45 but cross- sectional area 120 sqmmx3core
250
-
-
M &L for LT underground cable, heavy duty cable of size 240x3.5 core, 1100 Volts, XLPE insulated and PVC sheathed, armoured, multi-stranded aluminium conductor cable conforming to IS , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly protected in galvanised steel pipe of suitable sizes all bare conductor of cable including cable gland and lugs etc at both ends incl disconnecting all as specified and directed. Note : Excavation, earth work, cable sand cushioning & cable protection shall be measured separately under relevant items of this schedule.
50
-
-
All as per item no 47 but cross -sectional area 95 sqmm x 3.5 core
250
-
-
All as per item no 47 but cross -sectional area 50 sqmm x 3.5 core
500
-
-
All as per item no 47 but cross -sectional area 35 sqmm x 3.5 core
300
-
-
All as per item no 47 but cross -sectional area 16 sqmm x 4 core
500
-
-
All as per item no 47 but cross -sectional area 10 sqmm x 2 core
200
-
-
S& fixing 1100 voits grade of heavy duty of size 16 x2 core (two single core flat or circular) stranded coductor of caple PVC insulated aluminium conductor ,served with inner sheathing of PVC tape and overall PVC sheathed in service connection.
200
-
-
Taking down unserviceable/damaged LT/HT Cable from treches/nalah or road crossing etc retreived from item no 44 to 53 all as specified & directed
2650
-
-
M & L for cable end jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 to 185 sqmm including testing after jointing complete all as specified & directed.
3
-
-
All as per Item No 54 here and before but 11 KV 240 to 300 Sqmm indoor type.
1
-
-
M & L for cable end jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 to 185 sqmm including testing after jointing complete all as specified & directed.
6
-
-
All as per Item No 56 here and before but 11 KV , 240 to 300 Sqmm outdoor type.
1
-
-
All as per Item No 56 here and before but 33 KV , 240 to 300 Sqmm outdoor type.
2
-
-
M & L for straight through cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 to 185 sqmm including testing after jointing complete all as specified & directed.
2
-
-
All as per Item No 59 here and before but 11 KV 240 to 400 straight through type.
1
-
-
M&L for LT Cable,1.1 KV grade straight through jointing kit ,heat shrinkable type joint complete with jointing materials and accessories for 120 to 185 sqmmx3.5 core
5
-
-
M&L for LT Cable,1.1 KV grade straight through jointing kit ,heat shrinkable type joint complete with jointing materials and accessories for up to 95 sqmmx3.5/4 core
5
-
-
M&L for LT Cable,1.1 KV grade cable end jointing kit ,heat shrinkable type joint complete with jointing materials and accessories for 120 to 240 sqmmx3.5 core
4
-
-
M&L for LT Cable,1.1 KV grade cable end jointing kit ,heat shrinkable type joint complete with jointing materials and accessories for up to 50 to 95 sqmmx3.5 core
4
-
-
M & L for switch air break gang operated triple pole out door type 11 KV 50 cycle AC suitable for current rating upto 200 Amps mechanically operated mounted on porcelene insulators (9 insulators) and frame with operating mechanism from ground level with earth switch and including locking arrangement complete including taking out unser GOD all as specified & directed
5
-
-
M & L for switch air break gang operated triple pole out door type (Horizental) as reqd at site ,33 KV 50 cycle AC suitable for current rating upto 400 Amps mechanically operated mounted on porcelene insulators (9 insulators) and frame with operating mechanism from ground level with earth switch including taking out unser GOD all as specified & directed
2
-
-
S & F horn gap type of fuses,expuision type single pole, 33 KV mounted on post insulators porcelene type with gun metal clamps and copper horn complete of 400 Amp including two coats of aluminium paint over a coat of red oxide primer on MS work complete including taking out unser GOD all as specified & directed
3
-
-
Supply and fixing female contact spring loaded having brass contacts suitable for GOD up to 400 Amp for working p[ressure 11000 volts ,galvanised iron bolts,nuts and washers for fixing with post insulaor or any other indicating situation complete all as specified & directed
6
-
-
Supply and fixing Male contact spring loaded having brass contacts suitable for GOD up to 400 Amp for working p[ressure 11000 volts ,galvanised iron bolts,nuts and washers for fixing with post insulaor or any other indicating situation complete all as specified & directed
6
-
-
supply and fixing copper braided belt 400mm long with MS Carrier suitable suitable for GOD up to 400 Amp for working p[ressure 11000 volts ,galvanised iron bolts,nuts and washers for fixing with post insulaor or any other indicating situation complete all as specified & directed
6
-
-
M & L for lightning arresters porcelene type 12 KV grade complete with all fittings, expulsion type,tranmission class, discharge capacity 65 Kilo Amps complete all as specified and as directed incl taking down old u/s complete
5
-
-
M & L for lightning arresters porcelene type 33 KV grade complete with all fittings, expulsion type, transmission class ,discharge capacity 65 Kilo Amps
2
-
-
Dismantling and taking out old unserviceable cross arms and M&L for cross arms, bracing, supports clamps back plates, gantry bay structure etc fabricated from structural steel section such as suitable I section channel ISMC angle iron and flat iron GI nut, bolt & Washers with welding, cutting, drilling hole etc for insulator bolts clamps in any shape and size including one coat of red oxide and two coats of epoxy heat resistant paint all complete all as specified and directed.
3
-
-
Dismantling existing steel poles/ struts, any size carefully for reuse including necessary excavation demolition of concrete shifting cost etc. and removing the old unserviceable rubbish etc complete all as specified and directed.
4
-
-
Fixing only Steel pole of any length & dia retreived against respective item no 69 incl loading,shifting,unloading errection in the vertical position all as directed & specified (Excavation and earth work and PCC for foundation channels, clamps ,nuts and bolts to be measured and paid for separately)
4
-
-
M&L for Earth continuity conductor on main earthing lead fixing to pole wall or buried in ground including bending/welding as per site requirement for earthing of GI strip 32 x6 mm including welding and jointing 02 Nos Nut, bolt & washer etc all as directed incl disconnection and taking down existing complete.
95
-
-
M&L for Earth continuity conductor on main earthing lead fixing to poles/panels/LAs or wall or buried in ground including bending/welding as per site requirement for earthing of GI wire 8mm including welding and jointing 02 Nos Nut, bolt & washer etc with earthing point all as directed incl disconnection and taking down existing complete.
125
-
-
M&L for Trimming/ prunning of tree branches upto 5 meters below & both sides to obtain clearance all around the LT over head lines / HT over head lines conductor upto 5 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as directed.
60
-
-
Supply and fixing HT Cable root indicator of cast iron embedded in PCC 1:3:6 type C2 (using 20 mm graded stone aggregate) of size 100x100x200 mm foundation up to ground level including necessary earh work in any of soil complete all as specified and directed
50
-
-
Supply and fixing danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white letters, figures and conventional skull bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT 25 x 20cm (11 KV) size all as specified and as directed.
20
-
-
M&L servicing of four pole structure complete including replacement of unserviceable jumper ,sleeve vice type connector GI Clamps T Connector run through clamps,bolt nuts washer connecting lugs/thimbles knife ,contacts applying petrolling jelly to the moving as well fixed contacts ,tighting all the connection for its smooth functioning and prepararing old painted surface of the structure such as poles ,crooss arms,bracing and supports clamps ,back plate complete painting of one coats of anti corrosive aluminium paint complete all as specified and directed ,Marking the pole no/feeder name with black enamell paint complete all as specified and directed Note :No extra payment will be made for the spares reqd to keep the four pole structure in satisfactory functioning state throughout contract period other then given in schedulesdirected at site by Engr in charge.note : contacs & copper braided belt shall be paid & measured separately from the respective items if required.
4
-
-
All as per item no 82 here and before but 2 Pole structure
6
-
-
M&L for scraping of old paint from steel tubler pole 11 mtr height incl cross arms with out removing accessories and preparation of surfaces for repainting complete painting of one coats of anti corrosive aluminium paint complete all as specified and directed ,Marking the pole no/feeder name with black enamell paint complete all as specified and directed
25
-
-
Dismentling fencing wire mesh , any type complete all as specified and directed
60
-
-
Dismantling RCC posts or sruts any section ,including taking out embedded portion and making good disturbed ground complete all as specified
10
-
-
Excavation in post holes (or similer holes) each n exc 0.5 cum.getting out and removing surplus soil to a distance n exc 50m complete all as specified
10
-
-
S&fixing mild steel work such as in angle iron for posts,horns including flat iron fillets ,nut,bolts,10mm dia MS bars as in the bar fixed to fencing posts for fixing of chain link fencing ,securing its etc including necessary cuttings,drilling,bolting or reveting etc as per site requirement and other similer works complete mild steel ,conforming to Fe-290 Gde E-165
210
-
-
Supply only chain link fencing made of 4mm dia mild steel galvanised wire and 100x100mm mesh complete all as specified
250
-
-
Fixing only chain link fencing including line wires, any mesh,size and type to any any type to standards,rails,straining bolts etc including provision of binding wire complete all as specified
60
-
-
Paintig to sub stn gates of size 2.30 Mx1.70 M with two coat of enamel paint over a coat red oxide primer after scrapping thorougly the existing correded paint ,dirt/dust,oil &grease all as specifed and directed
4
-
-
S&F MCCBs in existing LT panel box /Feeder piller boxes of capacity 400 Amps 4pole breaking capacity 35KA Ics=100% Icu with thermal as well as magnetic balance adjustable setting type inclding taking down old unserviceable burnt out MCCB complete
2
-
-
S&F MCCBs in existing LT panel box /Feeder piller boxes of capacity 200 Amps 4pole breaking capacity 25 KA Ics=100% Icu with thermal as well as magnetic balance adjustable setting type inclding taking down old unserviceable burnt out MCCB complete
2
-
-
S&F MCCBs in existing LT panel box /Feeder piller boxes of capacity 100 Amps 4pole breaking capacity 16 KA Ics=100% Icu with thermal as well as magnetic balance adjustable setting type inclding taking down old unserviceable burnt out MCCB complete
3
-
-
Taking out transformer from its position from location under GE DDn for repair/servicing/rewinding of following capacity with OLTC ,11/.415 KV, disconnecting/ opening HV,LV electrical ,earthing connections complete with transportation to authorised workshop (upcl authorised company as approved by accepting officer making necessary arrangements of T&P (Crane,recovery,vehicle etc)
-
-
-
(a) 100 to 250 cap
1
-
-
(b) 315 to 500 cap
2
-
-
M&L for opening of transformer top cover by extraction ,removing of serviceable/unserviceable nuts bolts and washers etc and Lifting primery(HT) and secondry coil (LT) ,dismatling of transformer complete part by part carefully & display all the parts with out damaging any portion for inspection complete ,removing of trf oil for filtteration or changing as per die elecric strengh and condition of oil incl checking of leakage of transformer body and welding wks required for making tfr body leak proof complete all as specified and directed for the following capacity transformers
Note : Dehyderation,Filteration,new oil for changing/topping up, copper winding wire ,bushing,tfr cover gasket etc shall be measured and paid separetely under respective items of this sch.
-
-
-
(a) 100 to 250 cap
1
-
-
(b) 315 to 500 cap
2
-
-
M&L for trasformer winding including taking out and testing for serviceability and rewinding the same with fresh copper wire or strip incuding insulation paper bobins,press board incl replacement of sudry itens whereever required comlete and keeping the same into the hot air oven till the moisture will remove and insulating resistance improves to satisfaction level with heating ,drying etc complete ,reassembling the same in original position with all existing seviceable parts and new parts as per required complete all as specified and directed Note : Old unserviceable copper scrap will be retained by contractor under sch of credit
400
-
-
M& L for unserviceable cracked/worn out synthetic rubberised cork gasket sheet 6mm thick for top cover of transformer of follwoing cap incl nut bolt ,washers complete all as specified and directed
-
-
-
(a) 100-250 cap
1
-
-
(b) 315-500 cap
2
-
-
M&L for defective worn out HT bushing rod(Stud) complete made out of copper/brass with nut &washers for as per site requirement of following cap complete all as specified &directed
-
-
-
(a) 100-250
1
-
-
(b) 315-500
2
-
-
M&L for defective worn out LT bushing rod(Stud) complete made out of copper/brass with nut &washers for as per site requirement of following cap complete all as specified &directed
-
-
-
(a) 100-250
1
-
-
(b) 315-500
2
-
-
M&L for complete overhauling of On Load Tap Changer (OLTC) and including replacement of wiring conductors ,connectors including wiring of control cable connections complete all as specified and directed
-
-
-
(a) 100-250
1
-
-
(b) 315-500
2
-
-
Supply & filling the new transformer oil, confirming to IS ,die electric strengh of oil shouid not less then 50 KV at 2.5 mm gap of for topping up/replacement to required level of transformer complete all as specified and directed.
775
-
-
Supply and fix transformer breathers transparent of standard size suitable for 3.15 MVA transformers 33/11 KV volts cast alluminium transparent type including removing the existing u/s one complete all as specified.
1
-
-
Filtration/dehyderartion of the existing transformer oil at site of any make of transformer and capacity upto required dielectric strength as per IE rules and refilling in the transformer upto required level complete. (The diectric strength should not be less than 50 KV at 2.5 mm gap after filtration process)
10500
-
-
Supply & Fixing in replacment of aluminium body silica gel breathers of standard size suitable for up to 500 KVA Transformers 11KV/433 volt transparent type including removing to existing unserviceable one complete all as specified
4
-
-
Taking out the old Silica gel in the breather of transformer and supply and refilling new Silica gel in the breather as specified
3
-
-
Return back from work shop with placement of transformer to its position at location under GE DDn after repair/serviceing/rewinding inclding painting complete with two coats of synthetic enemal paint on tfr body incl cooling coils/fins by removing of all dirt ,grease etc marks using chemical or hot blow lamp of cap 11/.433KV ,Reconnecting HV,LV electrical connections,along with following other wks like checking & testing of HT Line/HT Cable ,HT Switch gearr etc complete all as specified and directed for the following capacities transformerc NOTE : (a) All routine tests will be carried uut at work shops (b) Transformer will have warranty of 6 month from the date of refixing at site (c) Any other work required to carry out above job in inclusive
-
-
-
(a) 100-250 KVA
1
-
-
(b) 315-500 KVA
2
-
-
M& L for Preventive maintenace /repairs to transformer step down 11 KV/.433 KV of any type & cap up to 500 KVA of any make including cleaning the transformers externally througly with lint free cloth ,tightening the HT/LT terminal nuts,opening the top cover for replacing the gaskets & bushings etc replacing the worn out copper alloy nuts-bolts and replacing the LT side cable lugs with tapping of taplon taps incl tighting all connectins with earthing terminals complete inclding painting complete with two coats of synthetic enemal paint on tfr body incl cooling coils/fins by removing of all dirt ,grease etc marks using chemical or hot blow lamp all as specified & directed NOTE : all other items which are required shall be measured and paid separetely under respective items of this sch.
10
-
-
"M&L for replacement of unserviceable earthing with G I electrode chemical advance maintenancefree chemical gel earthing GI electrode 50mm dia thick buried directly in ground vertically to a depth not less than 3.00 mtr below ground level filled with highly conductive metalic compound mixture CCM with the permanent sealing of the both end, outer dia pipe 50mm with strip terminal 50x6 with terminal holes incl one bag 50 kg of bfc compound, earth connected by earth lead copper strip/GI wire by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to transformer body/neutral point/panel boards etc protected by galvanized iron pipe LG 40/15mm bore, PVC chamber as per manufacturer instruction and testing on completion. Note: (i) Earthing has to done by CPRI approved firm and if the desired earth resistance is not found within permissible limit shall be redone by contractor at no extra cost(ii) GI strip and Protection pipe of GI shall be measured & paid separately in the relivent items.
27
-
-
Supply ,Installation, commissioning & testing in repair of factory made ,any CPRI approved ,LT switched gear panel board,IP-54(outdoor type) ,415 voils,50 Hz,AC supply,three phase and neutral (4 wie) ,600 Amps aluminium busbars 4 pole ,duly insulted with heat shrinkable sleeve as per colour code supported on epoxy insulatators,having independent compartment for insulated busbar ,incoming feeder & each outgoing feeder ie cubical type ,made out of 3.15 mm thick CRCA sheet,rigid mild steel angle iron frame of 50mmx50mmx6mm with 900mm long extended legs grouting in PCC 1:3:6 type C2 block of size 300mmx200mmx300mm ,duly epoxy powder coated internally & externally with approved shade ,rubber gasket,hinged front & back openable doors with proper locking arrangements for dust and vermin proof ,complete including suitable size cable alley,lugs,cable glands,common earth bar of GI strip 32x6mm at bottom and making connections with MCCB spreaders/wiring with suitable size FRLS copper conductor cable ,locking arrangements 65mm size and lock with keys,earth work and excavation comprising the following and specified hereafter :-LOCATION : MAP MD ACCN & 447 ASC
INCOMING :-
(i) MCCB 415 volt ,400 amps ,4pole,adjustable thermal magnetic release 80 to 100% ,35 KA (Ics=100%Icu)-01 NO
(ii) Spreader link =1set (iii) Rotery operated handle =01 set.
(iv) Aluminium busbars suitable for 300Amps,3Phase,4wire system=1 set
(v) Digital Ampare meter with CT(for each phase) square type with selector switch = 01 No.
(vi Digital Volt meter square type with selector switch = 01 No
(vii) LED type indication lamps (R-Y-B)with holder panel mounting type-1 no
OUTGOING :-
MCCB 415 volt ,100amps ,4pole,adjustable thermal magnetic release 80 to 100% ,25 KA (Ics=100%Icu)-07 Nos
(ii) Spreader Link -8set
(iii) Rotery Operator handle = 08 NosMCCB 415 volt ,200amps ,4pole,adjustable thermal magnetic release 80 to 100% ,35 KA (Ics=100%Icu)-01 NO
2
-
-
Note :-(i) for srl no 110,111 - All type test cirtificates with switch gear (ACB/MCCB) confirmimg to IEC 614398/2011 para 1&2 shall be submitted by the contractor before execution of work.
(ii) Drawing for LT Panel of suitable specific size shall be submitted with accommodate all the controls & suitable size of Bus bar incl provn of measuring instuments /indication lamps before execution of wks.
-
-
-
Taking out Serviceable Transformer of capacity 3.15 MVA from its position by disconnecting HT 33/11 KV cnnections , Earthing connections(body /neutral) ,oil , fins ,conservator ,tap chnger with all parts carefully which are applicable for carefully shifting etc incl removing of serviceable trf oil from its tank carefully for reuse transportation from MRS Anarwala to MRS Garhi by making neccessry arrangements of T&P(Crane,Hydra,Vehicle etc) and Unloading with fixing on Tfr Plate form of 5MVA incl attachments of all disconnecting spares and dehydration of tfr oil up to BDV 55-60 KV with topping up with making HT33/11KV connections,Earthings etc testing complete on existing loads as directed by Engr-in-charge
1
-
-
Taking out Serviceable Transformer of capacity 5MVA from its position by disconnecting HT 33/11 KV cnnections , Earthing connections(body /neutral) ,oil , fins ,conservator ,tap changer ,Relays duration with all parts carefully which are applicable for carefully shifting etc incl removing of serviceable trf oil from its tank carefully for reuse transportation from MRS Garhi to MRS Anarwala by making neccessry arrangements of T&P(Crane,Hydra,Vehicle etc) and Unloading with fixing on Tfr Plate form of 3.15 MVA incl attachments of all disconnecting spares and dehydration of tfr oil up to BDV 55-60 KV with topping up with making HT33/11KV connections,Earthings etc testing complete on existing loads as directed by Engr-in-charge Note for srl no 110 &111 : 1. dehydration of Tfr oil & topping up new Tfr oil will be paid saperately in respective items
2. Shifting works will be done by State electricity lience athorised person for electric works 3.All Mandatoty field tests will be carried out before giving loads
4. Any tear &wear,damage of tfr in the duration of shifting/installation ,Contractor should be repaire it own cost . 5. Power transformer wiil be charge on complete full load after completion of installation in presence of Engr-in -charge for fully satisfaction in all respect
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%