Military Engineer Services Tender
View complete overview of Uttarakhand MES Tender
Military Engineer Services - MES Tender

Civil And Construction
Machinery and Tools
Water Storage And Supply
Eprocure
Opening Date26 Dec 2024
Closing Date30 Jan 2025
Tender Amount₹ 3,36,52,500
Costs
EMD
₹ 4,11,600Document Cost
₹ 2,000Tender Fee
Refer Documents
Description

Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_690500_1Bid Award Id
ViewTender No
CEBZ/MRT/T-34 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/

GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Note for Maintenance and operations for 10 Years :- (a) Operate SCADA system during Defect Liability Period for two years after completion of work without manning ( Contractor to provide month wise breakdown details of data / information) all as specified and as directed by Engineer-in- charge. (b) Operation and comprehensive mainenance of SCADA systems including cost of spares for 08 years post defect liability period,operation including payment of bills by telecom service provider (Contractor to provide month-wise breakdown details of data / information). all as specified and as directed by Engineer-in- charge.
-
-
-
... More
NOTE :- COMPONENT OF PAYMENT FOR ITEM NO -1. (a) Sucessfully installation and operation of SCADA on completion of work :- 71.44 % of quoted rate of item No -1, Paymentto be regulated as per clause No 4 (a) of Particular Specification of (Water Supply SCADA) (b) 1st year under defect liability period after completion :- 1.44 % of quoted rate of item No -1.
-
-
-
... More
(c) 2nd year under defect liability period after completion :- 1.44 % of quoted rate of item No -1. (d) 1st year after defect liability period after completion :- 2.85 % of quoted rate of item No -1. (e) 2nd year after defect liability period after completion :- 2.85 % of quoted rate of item No -1.
-
-
-
... More
(f) 3rd year after defect liability period after completion :- 2.85 % of quoted rate of item No -1. (g) 4th year after defect liability period after completion :- 2.85 % of quoted rate of item No -1. (g) 5th year after defect liability period after completion :- 3.57 % of quoted rate of item No -1.
-
-
-
... More
(f) 6th year after defect liability period after completion :- 3.57 % of quoted rate of item No -1. (g) 7th year after defect liability period after completion :- 3.57 % of quoted rate of item No -1. (g) 8th year after defect liability period after completion :- 3.57 % of quoted rate of item No -1.
-
-
-
... More
Part II:- The following items are under AMC period:-
-
-
-
... More
Supply and fixing pressure Transmitter with accessories and sensor complete all as specifoed and directed.
2
-
-
... More
Supply and fixing Ultrasonic Level Transmitter with sensor complete all as specifoed and directed.
2
-
-
... More
Supply and fixing 100 mm dia, single phase, motor actuated butterfly valve with disc material of CI with nylon coated complete all as specifoed and directed.
2
-
-
... More
Supply and fixing 150mm dia, single phase, motor actuated butterfly valve with disc material of CI with nylon coated complete all as specifoed and directed.
4
-
-
... More
Supply and fixing ARM7 based CPU card of RTU complete all as specifoed and directed.
3
-
-
... More
Supply and fixing AI card of RTU complete all as specifoed and directed.
3
-
-
... More
Supply and fixing DO card of RTU complete all as specifoed and directed.
3
-
-
... More
Supply and fixing DO termination PCB of RTU complete all as specifoed and directed.
3
-
-
... More
Supply and fixing DI termination PCB of RTU complete all as specifoed and directed.
3
-
-
... More
Supply and fixing UPS of RTU complete all as specifoed and directed.
5
-
-
... More
Supply and fixing MODEM of RTU complete all as specifoed and directed.
5
-
-
... More
Note : Tenderers may note that amount of credit Rs 12200.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
-
-
-